MENDOTA DXV-35 GAS DIRECT VENT FIREPLACE
SPECIFICATIONS & CLEARANCES FOR TOP VENTING WARNING: Do not cover the 2” faceplate border of the unit with combustible materials.
26 1/4 37 1/8 22 1/4
6"MIN.
10 3/4 11 1/8
1"MIN.
4 1/2
15 3/8
35 7/8
1/2 TO 2 1/2
52 1/2
10" MINIMUM FRAMING DIMENSIONS FOR THE DIRECT VENT
31-1/2
HEIGHT
45°
(800 mm)
37 1/8
WIDTH
(943 mm)
16
DEPTH
(407 mm)
Adjacent Walls: A wall, perpendicular to and in front of the appliance front facing must be at least 10" from the firebox opening. A wall at 45° to the front and starting at the appliance's outer edge is permitted. Projections behind this wall (shaded area) are permitted.
COMBUSTIBLE MANTEL MUST REMAIN IN THIS TRIANGULAR AREA. FOR EVERY 1" INCREASE IN MANTEL DEPTH, INCREASE HEIGHT ABOVE GRILL IF DEPTH IS BY 2". MANTEL MAY BE LOWERED DECREASED IN THE SAME MANNER
1
2 2" MIN.
8" MANTEL DEPTH (WIDTH)
8" COMBUSTIBLE MANTEL
14 MIN. FROM TOP OF GRILL TO 8" MANTEL
14" MANTEL HEIGHT FOR 8" MANTEL
32
1" MIN.
MIN. 9" SECTION
40 7/8
16 1/4 MIN. FROM TOP OF UNIT TO STACK CENTER
49 1/2" MIN. CLEARANCE TO COMBUSTIBLE ABOVE UNIT & MINIMUM CEILING HEIGHT
31 1/2 29 4 5/8 GAS INLET NON-COMBUSTIBLE HEARTH PROTECTOR REQUIRED
1 7/8
2 1/2 85-03-00458
12 NOTE: FOR EVERY 1" THE FIREPLACE IS RAISED OFF THE FLOOR, HEARTH PROTECTOR MAY BE REDUCED BY 2". IF FIREPLACE IS RAISED 6" OR MORE, NO HEARTH PROTECTION IS REQUIRED.
IF MANTEL IS MADE OF A NON-COMBUSTIBLE MATERIAL (BRICK, STONE, ETC..), OR HAS A STEEL PROTECTOR PLATE ON THE UNDERSIDE IT MAY BE PLACED ANYWHERE ABOVE GRILL
Figure 4: Specifications & Clearances
NOTE: For L.P. & High Altitude (above 4,000 ft. but below 7500 ft.), 45º elbows must be used in place of 90º elbows (see pg. 15 FOR INSTALLATION AT ALTITUDES ABOVE 7,500 FEET, FIRST CALL MENDOTA TECHNICAL HOTLINE FOR FURTHER INFORMATION ON THE STRICT REQUIREMENTS FOR INSTALLATIONS AT THESE ALTITUDES. Using 45o elbows requires 19" minimum opening to center (see page 15 CAUTION: If 90ºelbows must be used with LP or at high altitudes, a 3-foot vertical starter section must be used directly off the top of the fireplace. 12