DAISY™: Door Alarm Indication System

Page 1

®

DAISY™: Door Alarm Indication System Proven Behavioral Healthcare Solutions Supporting a secure, comfortable, healing environment

Securitech’s Door Alarm Indication System is designed to alert nursing staff to a patient-harm situation, while blending in to the room to promote a calm environment Thousands of patients are protected by the DAISY™ system technology each and every day. Applications: Behavioral Healthcare Wards Intake Rooms VA Medical Centers


DAISY™ Multi-Door Door Alarm Indication System

Protecting Patients:

Swinging doors present an opportunity for patients to harm themselves. Securitech created alarm sensors for doors which notify staff when there is an attempt to cause harm at the door. The aesthetic, curved design resembles applied molding and supports the concept that visible hardware should support the serene environment. Related consoles, key switches, strobes, and other peripheral items enable the creation of complete notification systems. While there is no replacement for continuous observation, Securitech’s DAISY™ is a useful tool to aid the nursing staff. The attractive rounded sensor bar at the top of the door pivots when pressure is applied and sends a signal to a strobe above the door in the corridor and to the nurse station console. DAISY™ alarms can only be reset by visiting a door after notification of an incident, assuring a physical response. DAISY™ console is a simple notification system, with no training , software or computer system required.

Design Flexibility

Customizable to meet your needs. Considerations include: • Corridor or in-room bathroom door • Door swing • Sensors on pull or both sides of door • Single direction swinging door or double acting • Desk or wall mounted console • Multiple console locations

Simplicity of Design

Aesthetically Designed To Detect Items Draped On Door

• Curved bar design and multiple sensors detect pressure placed on door • Neutral beige color blends in with environment • Durable construction, mounts securely to the door

Life-Safety System Design • Staff member must visit emergency door in order to shut off alarm

Signaling Options

• Designed to be easily integrated into the layout of any facility • Provides alarm signals to console and strobe • Nuisance alarm (tapping does not trigger alarm: field programmable) • Optional remote signal output

DAISY™ has been designed without software or programming. There’s no computer, monitor, annual maintenance agreements, upgrades or complicated nurse training.

Certifications

Fire Door Applications • Approved to be used as a component in a Fire Door assembly with up to 3-hour rating with hose stream

Strobe Light

Desk Console

DAISY™ Sensor Bar

Ligature-Resistant Transfer Hinge Wall Mounted Console

FS1 (left), DALAH (right) Key Reset Switch DAISY™ bar and full length hinge with exclusive frame header segment

Splice Box


Sample System Layout

How to build your DAISY system: • DAISY™ Bar; one per door • DAISY™ Hinge; one per door • DALAH™ Hinge; Used on double acting doors. • Reset Key Switch; located outside each room • Strobe Light; located outside each room • Power Supply and Controller (12/24/36 door system) • Nurse Station Console; Desk or Wall Mounted (12/24/36 door system) • Additional Console or Output; Optional, to meet facility requirements • Inner door option; Splice box integrates one bathroom + bedroom door on nurse console; shared reset keyswitch and strobe; reduces wire runs required to room Controller • DAISY™ is a hardwired run Console 110vACsystem, requiring a direct from the controller to each room.

Controller

Console

110vAC

Low Voltage Circuits 1

2

3

4

5

Door Sensor Assembly & Hinge Power Transfer

3

4

Sample Wire Run

5

6

7

8

9

10

11

12

110vAC

One per door

Keyswitch

One per door or room

Strobe Light

One per door or room

From

110vAC

To

Controller

-Power for console & LEDs -Input for Door Sensor Assemblies and Keyswitches -Outputs for strobe, siren and dry contact -Specify 12, 24, 36 or 48 door capacity -Adjustable “Nuisance alarm” timer -Includes piezo siren, status LED for each door, silence button -Adjustable piezo volume dial within console (not visible)

#

Size

One per door or room

Keyswitch

To

-Power for console & LEDs -Input for Door Sensor Assemblies and Keyswitches -Outputs for strobe, siren and dry contact -Specify 12, 24, 36 or 48 door capacity -Adjustable “Nuisance alarm” timer -Includes piezo siren, status LED for each door, silence button -Adjustable piezo volume dial within console (not visible)

#

Size

Application

Power

Controller Console 3 18 AWG Power & Alarm Controller Console 12 22 AWG LEDs Controller Console 2 22 AWG Silence Button

Application

Please Note: Wire gauge may change when longer distances are involved

Controller Door 1 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 2 6 18 AWG Sensor, Strobe, Keyswitch Controller Controller Door 3 6 18 AWG Sensor, Strobe, Keyswitch Console 110vAC Controller Door 4 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 5 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 6 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 7 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 8 6 18 AWG Sensor, Strobe, Keyswitch Low Voltage Circuits Controller Door 9 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 10 6 18 AWG Sensor, Strobe, Keyswitch 1 2 3 4 5 6 7 8 9 Controller Door 11 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 12 6 18 AWG Sensor, Strobe, Keyswitch

Please Note: Wire gauge may change when longer distances are involved

One per door

Strobe Light

Controller

Power

Controller Console 3 18 AWG Power & Alarm Controller Console 12 22 AWG LEDs Individual Door Elements Controller Console 2 22 AWG Silence Button Door Sensor Assembly & Hinge Power Transfer

11

Controller Door 1 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 2 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 3 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 4 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 5 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 6 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 7 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 8 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 9 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 10 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 11 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 12 6 18 AWG Sensor, Strobe, Keyswitch

Individual Door Elements

Console

10

One per door or room

Console

From

Controller/Power Supply

9

Individual Door Elements

Individual Door Elements Door Sensor Assembly & Hinge Power Transfer

8

Keyswitch

Controller/Power Supply

2

7

Individual Door Elements

Low Voltage Circuits 1

6

10

11

One per door One per door or room

12

12


ELEMENTS Door Sensor Assemblies

ELEMENTS

Doo

DSY-DSA-P1-__ DSY-DSA-P2-__ DSY-DSA-P6-__ DSY-DSA-P5-__ DSY-DSA-P0-__

36" to 42" door width 42" to 48" door width 29" to 35" door width 35" to 41" door width Less than 28"door width; consult factory

DSY-FS1-6-2W

Flat profile 2-wire anti-lig sensor. 6-1/8" x 2" x 3/8". Used when door may impact frame in center hung or deep reveal applications. FS1 projects only 3/8" from the door's face and has an integral stainless steel impact bumper to protect the FS1 and door. FS1 can be used with DALAH double acting hinge sensors or electrified pivots by others.

Con

Exposed door width must be measured when a sensor bar is also applied to the push side of the door

Controller DSY-1A52-12

Controller/Power Supply for a 12 room DAISY including: Door sensor (DSA) inputs Reset keyswitch inputs Strobe output Console output Remote signal output Remote siren output Adjustable "Nuisance" delay (factory pre-set: 3sec) Note: Requires 110v input

DSY-1A52-24 DSY-1A52-36

Con

Same as above, for up to 24 rooms Same as above, for up to 36 rooms

Contact Factory For Custom Configurations

Con

Controller Modifications DSY-CPS-MOD-2

2nd console output (for 2nd nurse or guard station)

Console DSY-DCRS-12

Desk mounted console for 12 room DAISY including:

DSY-DCRS-24 DSY-DCRS-36 DSY-WCRS-12 DSY-WCRS-24 DSY-WCRS-36

Same as above, for up to 24 rooms Same as above, for up to 36 rooms Wall-mounted console for 12 room DAISY Wall-mounted console for 12 room DAISY Wall-mounted console for 12 room DAISY

Wall mounted units require recessing within drywall; all other elements identical to DCRS-12

Keyswitch DSY-KS101

Wall mounted keyswitch (single gang box by others) Mortise cylinder required (by others)

Strobe Light DSY-SL1 DSY-SL2

Strobe light for ceiling mounting (use with ceiling tiles) Same as above with steel mounting plate

Ligature‐Resistant Transfer Hinge DSY-ECHFS-MH-AL-4-(handing) (height - 84" standard)

Full-surface angled aluminum hinge modified for use with DAISY Handing and size required when ordering

DSY-DALAH-8-2W

Double acting upper 8" tall hinge element contains dual anti-lig sensors and a 2-wire signal transfer for use with FS1 and all Daisy Sensor Bars. Order with the lower A508 hinge element, sold separately.

DSY-DALAH-A508-HT

c:\mb x1 files\xi docs\technical\seda\DAISY Elements v1.vsd\page-1\as of5/2/17

LED (1 Green/Red per room) Momentary piezo silence button Piezo volume adjustment (within console)

Keys

Stro

Elec

Acce

Double acting DALAH hinge made in u.s.a.shown by SECURITECH GROUP, INC. 54‐60 need with FS1

Full length stainless steel pin-in-barrel double acting hinge element for use with DALAH upper sensor section. To order, specify full height of opening, less 8-1/8" for DALAH. Contact factory for ordering requirements.

Contact factory for different finish or use with electrified locks

Accessories DSY-SPLB-1

Splice box for use within room containing multiple doors Up to 5 doors… splice within room to reduce wire run

DSY-DSA

Manufactured in the USA

2nd door sensor where additional door monitoring is advisable

54-60 46th St. Maspeth, NY 11378

FS1 used with center hung pivot and DAISY sensor