CIRCUIT PROTECTORS

Page 1

08

Individual catalog No.

LOW VOLTAGE PRODUCTS Up to 600 Volts

01

Magnetic Contactors and Starters Thermal Overload Relays, Solid-state Contactors

02

Manual Motor Starters and Contactors Combination Starters

03

Industrial Relays, Industrial Control Relays Annunciator Relay Unit, Time Delay Relays

04

Pushbuttons, Selector Switches, Pilot Lights Rotary Switches, Cam Type Selector Switches Panel Switches, Terminal Blocks, Testing Terminals

05

Limit Switches, Proximity Switches Photoelectric Switches

06

Molded Case Circuit Breakers Air Circuit Breakers

07

Earth Leakage Circuit Breakers Earth Leakage Protective Relays

08

Circuit Protectors Low Voltage Current-Limiting Fuses

09

Measuring Instruments, Arresters, Transducers Power Factor Controllers Power Monitoring Equipment (F-MPC)

10

AC Power Regulators Noise Suppression Filters Control Power Transformers

INDIVIDUAL CATALOG from D&C CATALOG 20th Edition

D&C CATALOG DIGEST INDEX

CP-F type Circuit protectors

CP-P type Circuit protectors

CP-B type Circuit protectors

CIRCUIT PROTECTORS CP-V type Circuit protectors

LOW VOLTAGE CURRENT - LIMITING FUSES

HIGH VOLTAGE PRODUCTS Up to 36kV

11

Disconnecting Switches, Power Fuses Air Load Break Switches Instrument Transformers — VT, CT

12

Vacuum Circuit Breakers, Vacuum Magnetic Contactors Protective Relays

AFaC and BaC types HRC fuses

LOW VOLTAGE EQUIPMENT Up to 600 Volts

INDIVIDUAL CATALOG from D&C CATALOG 20th Edition

BLC, CR and CS types Super Rapid Fuses

INDIVIDUAL CATALOG

08

from D&C CATALOG 20th Edition 01 02 03 04 05 06 07

5-7, Nihonbashi Odemma-cho, Chuo-ku, Tokyo, 103-0011, Japan URL http://www.fujielectric.co.jp/fcs/eng

Information in this catalog is subject to change without notice.

2010-04 PDF FOLS DEC2008

08

09 10 11 12

08


08

Circuit protectors Low voltage fuses Page

Circuit Protectors

CP31F, 32F, 33F............................................................................................... 08/1 CP31, 31D, 32D............................................................................................... 08/5 CP31P, 32P, 33P.............................................................................................. 08/8 CP51B, 52B, 53B............................................................................................. 08/14 CP31E, 32E, 33E, 34E, CP31V, 32V, 33V, 34V............................................... 08/19

Low Voltage Fuses General information.......................................................................................... 08/25 Current-limiting fuses AFaC, BaC................................................................................................... 08/26 FCF, FCK..................................................................................................... 08/29 Super rapid fuses BLC, CR, CS................................................................................................ 08/31


MINIMUM ORDERS Orders amounting to less than 짜10,000 net per order will be charged as 짜10,000 net per order plus freight and other charges. WEIGHTS AND DIMENSIONS Weights and dimensions appearing in this catalog are the best information available at the time of going to press. FUJI ELECTRIC FA has a policy of continuous product improvement, and design changes may make this information out of date. Please confirm such details before planning actual construction. INFORMATION IN THIS CATALOG IS SUBJECT TO CHANGE WITHOUT NOTICE.


Circuit Protectors CP31F, 32F, 33F

CP-F slim type circuit protectors 250V AC/65V DC (1-pole) 0.1A to 30A 250V AC/125V DC (2-pole) 0.1A to 30A 250V AC (3-pole) 0.1A to 30A Description FUJI's compact and high-performance CP-F series circuit protectors incorporate FUJI's advanced technology. Their thin sizes make them ideal for use as AC/DC line switches in office and industrial equipment. ■ Features • Only 17.5mm wide — mounting space is reduced by 30% compared with conventional types. • AC/DC common use • Available with auxiliary switch and alarm switch • Also available in types having inertia delay characteristics • Trip-free mechanism • IEC rail mounting ■ Standards (File No.E96846) TÜV (IEC)(R9650230) CCC (China GB)(2003010309067080) ■ Accessories ● Auxiliary switch (Type W) This switch is used for ON-OFF lamp indicator or control circuit. ● Alarm switch (Type K) This switch can be connected to a warning lamp or buzzer to indicate when the circuit protector has been tripped. Auxiliary and alarm switches for low level circuit are also available on request. (Type W1, K1) ■

KKD09-078

CP31F

KKD09-095

KKD09-079

CP32F

CP33F

Specifications

Type

CP31F

CP32F

CP33F

Pole

1-pole

2-pole

3-pole

Rated insulation voltage (Ui)

250V AC 65V DC

250V AC 125V DC

250V AC –

Rated operatonal voltage (Ue)

240V AC 60V DC

240V AC 120V DC

240V AC –

Rated current

0.1, 0.3, 0.5, 1, 2, 3, 5, 7, 10, 15, 20, 25, 30A

Rated breaking capacity

2500A at 240V AC 2500A at 60V DC (1-pole) 2500A at 120V DC (2-pole)

Operating characteristic

Long time delay (AC circuit only) Medium time delay, Instantaneous tripping

Tripping mechanism

Hydraulic-magnetic

Ambient temperature Dielectric strength

–10 to +60°C 2000V AC 1min

Electrical durability

10000 operations or more

Terminals (Self-lifting)

Main circuit Auxiliary circuit

M5 (25A or over), M4 (20A or less) M3.5

Mass (Approx.)

80g

160g

240g

08 Main contact

Ratings of auxiliary and alarm switches

Auxiliary switch/W

ON

21

Standard type (Type W, K) 250V AC

Resistive load: Inductive load:

1A 0.5A

125V AC

Resistive load: Inductive load:

3A 1A

60V DC

Resistive load: Inductive load:

1A 0.5A

30V DC

Resistive load: Inductive load:

2A 1A

24V DC 12V DC 6V DC

20 30

OFF

13

11

12

TRIP 21

20 30 13

11

12

Number of auxiliary and alarm switches mountable

Minimum permissible load For low level circuit (Type W1, K1)

Alarm switch/K

1-pole

2-pole

3-pole

LINE

1mA 2mA 5mA

ON

LOAD

W, W1 K or K1 (Select one switch) K or K1

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice

ON

W+W or W1+W1 K+W or K1+W1 W or W1

ON

W or W1:

At right-pole

K or K1:

At left-pole

WW or W1 W1: At right-pole and center-pole WK or W1 K1: Aux. switch at right -pole and alarm switch at left-pole

08/1


Circuit Protectors CP31F, 32F, 33F

Snap-on mounting terminal covers For main terminal: CP-T4 For auxiliary terminal: CP-T5

CP-T5 AF92-559

CP-T4

5000

ø3.5

5

.7

R1

4000

1

46.6

2

3000 2000

9.8

1000

21.6

Scale factor of rated current (%)

Inertia delay characteristic 6000

5.5

3.5

Inertia delay device (Type D) This inertia delay device is designed to prevent the circuit protector from operating erroneously due to such inrush current and to carry out an interruption within the prescribed operating characteristics in the face of an overcurrent. The protector does not operate even when a pulse current of approx. 14 times (peak value) rated current with a pulse width of 10ms flows.

0 1 2 3 4 5 6 7 8 9 10 Pulse time (ms)

17.4

• Scale factor of the rated current (%) Peak value of pulse current × 100 Rated current of protector • Waveform of pulse current: Sinusoidal wave or parabolic pulse

12.8

12.8

20.4 12

23.5

28.8

Peak value of pulse current Pulse time

Characteristic curves Long time delay tripping type AC circuit only

2

Max. total fault clearing time

Min. value

1 0.8 0.6 0.4

Operating time

10 8 6 4

0.2 0.1 0.08 0.06 0.04

1.5 2

3

4 5 6 7 8 910

15 20

40 60 80 100

Multiple of rated current

Long time delay with inertia delay device AC circuit only

Minute

Max. value

10 8 6 4

Max. total fault clearing time

2 1 0.8 0.6 0.4

Min. value

10 8 6 4 2 1 0.8 0.6 0.4

0.2

0.2 0.1 0.08 0.06 0.04

Min. value

Max. value

20

0.1 0.08 0.06 0.04

Max. total fault clearing time

0.02 1

1.5 2

3

4 5 6 7 8 910

15 20

0.01

40 60 80 100

1

1.5 2

Multiple of rated current

3

4 5 6 7 8 910

15 20

40 60 80 100

Multiple of rated current

Ambient temperature compensation

Max. value

20 10 8 6 4 2

Min. value

1 0.8 0.6 0.4 0.2 0.1 0.08 0.06 0.04

Max. total fault clearing time

0.02 0.01

Scale factor of operating time (%)

Minute

10 8 6 4 2 1 40

Operating time

2 1 40

at 40˚C

60 50 40 30 20

Second

10 8 6 4

2

0.01 1

180 120 90 60 50 40 30 20

1 40

0.02

0.02 0.01

DC

20

Second

Max. value

20

Second

Operating time

2

AC

10 8 6 4

Second

10 8 6 4

180 120 90 60 50 40 30 20

Operating time

180 120 90 60 50 40 30 20

1 40

Instantaneous tripping type AC/DC circuit

Medium time delay tripping type AC/DC circuit Minute

Minute

160 120 100 80

Ref. temp.: 40˚C

60 40

-10

0

10 20 30 40 50 Ambient temp. (˚C)

60

0.006 1

1.5 2

3

4 5 6 7 8 910

15 20

40 60 80 100

Multiple of rated current

08/2

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice


Circuit Protectors CP31F, 32F, 33F

Versions Operating characteristic

CP31F (1-pole) Type

CP32F (2-pole) Type

CP33F (3-pole) Type

Without inertia delay device

Long time Medium time Instantaneous

CP31FS/씲 CP31FM/씲 CP31FI/씲

CP32FS/씲 CP32FM/씲 CP32FI/씲

CP33FS/씲 CP33FM/씲 CP33FI/씲

With inertia delay device

Long time Medium time Instantaneous

CP31FS/씲D CP31FM/씲D —

CP32FS/씲D CP32FM/씲D —

CP33FS/씲D CP33FM/씲D —

With standard auxiliary switch

Long time Medium time Instantaneous

CP31FS/씲W CP31FM/씲W CP31FI/씲W

CP32FS/씲W CP32FM/씲W CP32FI/씲W

CP33FS/씲W CP33FM/씲W CP33FI/씲W

With standard auxiliary switch and inertia delay device

Long time Medium time Instantaneous

CP31FS/씲WD CP31FM/씲WD —

CP32FS/씲WD CP32FM/씲WD —

CP33FS/씲WD CP33FM/씲WD —

With standard alarm switch

Long time Medium time Instantaneous

CP31FS/씲K CP31FM/씲K CP31FI/씲K

CP32FS/씲K CP32FM/씲K CP32FI/씲K

CP33FS/씲K CP33FM/씲K CP33FI/씲K

With standard alarm switch and inertia delay device

Long time Medium time Instantaneous

CP31FS/씲KD CP31FM/씲KD —

CP32FS/씲KD CP32FM/씲KD —

CP33FS/씲KD CP33FM/씲KD —

With auxiliary switch for low level circuit

Long time Medium time Instantaneous

CP31FS/씲W1 CP31FM/씲W1 CP31FI/씲W1

CP32FS/씲W1 CP32FM/씲W1 CP32FI/씲W1

CP33FS/씲W1 CP33FM/씲W1 CP33FI/씲W1

With auxiliary switch for low level circuit and inertia delay device

Long time Medium time Instantaneous

CP31FS/씲W1D CP31FM/씲W1D —

CP32FS/씲W1D CP32FM/씲W1D —

CP33FS/씲W1D CP33FM/씲W1D —

With alarm switch for low level circuit

Long time Medium time Instantaneous

CP31FS/씲K1 CP31FM/씲K1 CP31FI/씲K1

CP32FS/씲K1 CP32FM/씲K1 CP32FI/씲K1

CP33FS/씲K1 CP33FM/씲K1 CP33FI/씲K1

With alarm switch for low level circuit and inertia delay device

Long time Medium time Instantaneous

CP31FS/씲K1D CP31FM/씲K1D —

CP32FS/씲K1D CP32FM/씲K1D —

CP33FS/씲K1D CP33FM/씲K1D —

Note : ■

Enter the rated current in the

mark of the type number. 0.1A: 0.1, 0.3A; 0.3, 0.5A: 0.5 ------ 30A: 30

08

Type number nomenclature CP3 1 F M / 5 W D

Basic type CP3■F

Inertia delay device Blank: Without inertia delay device D: With inertia delay device (Except instantaneous type)

Number of poles 1: 1-pole 2: 2-pole 3: 3-pole (AC circuit only) Operating characteristics S: Long time delay tripping (AC circuit only) M: Medium time delay tripping I: Instantaneous

Accessories Blank: Without accessory W: With standard auxiliary switch W1: With auxiliary switch for low level circuit K: With standard alarm switch K1: With alarm switch for low level circuit WW:

Rated current 0.1: 0.1A 1: 0.3: 0.3A 2: 0.5: 0.5A 3: 5: 7:

1A 2A 3A 5A 7A

10: 15: 20: 25: 30:

10A 15A 20A 25A 30A

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice

With two standard auxiliary switches

W1W1: With two auxiliary switches for low level circuits WK:

With standard auxiliary and alarm switches

W1K1: With auxiliary and alarm switches for low level circuit

08/3


Circuit Protectors CP31F, 32F, 33F

Dimensions, mm

1-pole

2-pole

3-pole Mounting rail 35mm width IEC standard

TRIP indicator

ON TRIP OFF

54

54

TRIP indicator

54

5

φ 4.5

63

φ 4.5

67 56 45

φ 4.5

27

Main terminal M4: 20A or less M5: 25A or more

Main terminal M4: 20A or less M5: 25A or more

12

29.5

8.1

47

5

5 24.5

4

65

Mounting rail 35mm width IEC standard 27 5

Auxiliary terminal M3.5 With Aux. switch

Auxiliary terminal M3.5 With Aux. switch or alarm switch

ON TRIP OFF

63

Auxiliary terminal M3.5 With Aux. switch

Auxiliary terminal M3.5 With Aux. switch

52.5 max.

5

5

Auxiliary terminal M3.5 With Aux. switch or alarm switch Auxiliary terminal M3.5 With Aux. switch or alarm switch

35 max.

67 56 50.7

17.5max.

24.5 8.1

65

4

12

08/4

2-M4

29.5

2-M4

54

54

54

Panel drilling

47

2-M4

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice


Circuit Protectors CP31, CP31D, CP32D

CP31, CP31D, CP32D circuit protectors 250V AC 0.3A to 30A 50V DC 0.3A to 30A Description The CP31 and CP32 have a similar functions to a molded case circuit breaker and they can be used for normal switching ON and OFF operations while breaking both overload and short-circuit currents. They are available in two time-current versions—an instantaneous and a time-delay version. A suitable type should be selected to match the thermal and permissible current requirements. These are recommended for sequential control circuits, motor control circuits, solenoid-operated valves, heaters and solid-state applications. ■

Features • Excellent arc interruption Since the arc extinguisher uses a loop blow-out system the arc is rapidly extinguished. • Highly visible handle indication ON shows red and OFF or TRIP blue. • When positioned at ON the operating handle is completely housed inside the molded case and does not protrude. This helps to prevent erroneous operation. • Trip-free mechanism • Also available with auxiliary switch SPDT. • Two time-current versions— instantaneous operation and a time delay type. Select the model best suited to your protection needs. • CP31D and CP32D types are of front and rail dual mounting. ■

Loop blow-out conductor

Arc grid

With auxiliary switch

Time-delay tripping type CP31 (1-pole) Front mounting Type

Rail mounting Type

CP31D (1-pole) Type

CP32D (2-pole) Type

0.3 0.5 1 2 3 5 7 10 15 20 25 30

CP31/0.3 CP31/0.5 CP31/1 CP31/2 CP31/3 CP31/5 CP31/7 CP31/10 CP31/15 CP31/20 CP31/25 CP31/30

CP31/0.3X CP31/0.5X CP31/1X CP31/2X CP31/3X CP31/5X CP31/7X CP31/10X CP31/15X CP31/20X CP31/25X CP31/30X

CP31D/0.3 CP31D/0.5 CP31D/1 CP31D/2 CP31D/3 CP31D/5 CP31D/7 CP31D/10 CP31D/15 CP31D/20 CP31D/25 CP31D/30

CP32D/0.3 CP32D/0.5 CP32D/1 CP32D/2 CP32D/3 CP32D/5 CP32D/7 CP32D/10 CP32D/15 CP32D/20 CP32D/25 CP32D/30

Typical applications These CP31 and CP32 protectors are used for normal on-off switching of the power supply while also providing overload protection of the load circuits. ■

08

Type number nomenclature CP 3 1 ■ ■ / ■ X W DC

Basic type

SM-1384

Auxiliary swich

Time-delay tripping type • Control circuits • Solenoid valves and motor circuits • Heater circuits Instantaneous tripping type • Semiconductor circuits • SCR (Silicon controlled rectifier) and triac circuits • Computer peripheral equipment

Number of poles 1: 1-pole 2: 2-pole (CP32D)

OFF (TRIP)

Rail mounting

Rated current (A)

Frame size 3: 30A

ON

SM-1392

SH-956

Standard type

Rated breaking capacity Blank: 2.5kA at 250V AC 1.5kA at 50V DC D: 1kA at 250V AC 1kA at 50V DC Operating characteristics Blank: Time-delay tripping I: Instantaneous tripping S: Long time-delay tripping (AC circuit only)

Applied circuit Blank: AC DC : DC Optional accessory Blank: Without auxiliary switch W: With auxiliary switch Mounting and connection (CP31 only) * Blank: Front mounting front connection X: Rail mounting Rated current 0.3: 0.3A 0.5: 0.5A 1: 1A 2: 2A 3: 3A 5: 5A

7: 10: 15: 20: 25: 30:

7A 10A 15A 20A 25A 30A

SH-956

* One and the same CP31D and CP32D can be used for both front mounting and rail mounting.

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice

08/5


Circuit Protectors CP31, CP31D, CP32D

Normal load

■ Adaptor for flush mounting/CP-E1 These circuit protectors can be modified for flush mounting use by a snap-fitting adaptor CP-E1.

Spring Solenoid coil

Armature

Cylinder

Core Silicon fluid

Yoke

Fig. 2

Overcurrent

Fig. 3

Overcurrent trip

Flush mounting

Fig. 4

Short-circuit current trip

Specifications CP31D

CP32D

Pole Frame size Rated insulation voltage (Ui) Rated operational voltage (Ue) Rated current

1-pole 30 Amps. 250V AC, 50V DC

1-pole 30 Amps. 250V AC, 50V DC

2-pole

250V AC, 50V DC

250V AC, 50V DC

0.3, 0.5, 1, 2, 3, 5, 7, 10, 15, 20, 25, 30A

0.3, 0.5, 1, 2, 3, 5, 7, 10, 15, 20, 25, 30A

Rated breaking capacity

2500A at 250V AC 1500A at 50V DC

1000A at 250V AC 1000A at 50V DC

Operating characteristic

Time-delay tripping Instantaneous tripping Long time delay tripping

Time-delay tripping Instantaneous tripping Long time delay tripping

Ambient temperature Dielectric strength

–10˚C to +60˚C 2000V AC 1min.

–10˚C to +60˚C 2000V AC 1min.

Mechanical durability Electrical durability

10000 operations 10000 operations

6000 operations 6000 operations

Mass

Approx. 100g

Approx. 100g (1-pole), 200g (2-pole)

ON

OFF or Trip

20 21 30 20 21 30

125V AC 50V DC 30V DC

08/6

1 40 20 20 6 4 2 1 0.6 0.4 0.2 0.1 0.06 0.04 0.02

Time delay tripping type Long time delay tripping type Instantaneous tripping type

Max. total fault cleaning time

1.5 2

3 4

6 8 10

20 30 40 60 80 100

Multiple of rated current

Ambient temperature compensation (Time delay tripping type)

Auxiliary contact ratings 250V AC

at 40˚C

60 40 20 10 6 4 2

1

Auxiliary switch Auxiliary contact

Characteristic curve

0.01 0.006

Note: Specify DC only when ordering circuit protectors for DC circuits.

Main contact

Snap-on mounting terminal covers For main terminal: CP-T1 For auxiliary terminal: CP-T2

Minute

CP31

Front mounting

Description

CP-E1

SM-1385

Operating time Second

Fig. 1

Resistive load: 1A Inductive load: 0.5A Resistive load: 3A Inductive load: 1A Resistive load: 1A Inductive load: 0.5A Resistive load: 2A Inductive load: 1A

Scale factor of operating time (%)

■ Operation The operation of the magnetic overload release of the CP31, CP31D and CP32D circuit protectors are as shown in the sectional diagram Fig. 1. The magnetic tripping element of the circuit protector is simple—a solenoid coil wound around a hermetically-sealed non-magnetic cylinder containing a spring-loaded movable iron core and a silicon fluid. When currents less than the rated value flow no movement occurs in either the armature or iron core. However, when a sustained overcurrent occurs the magnetic field is increased. This causes the iron core to move along the cylinder. Once the core reaches the opposite end of the cylinder the armature is attracted which causes the protector to trip as shown in Fig. 2 and 3. When a short circuit occurs the magnetic flux produced in the coil alone is strong enough to attract the armature regardless of core position. This causes circuit to be interrupted instantaneously. (Fig. 4)

300 200 160 120 100 80 60

Ref. temp.: 40°C

40

-10 0 10 20 30 40 50 60

Ambient temp. (°C)

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice


Circuit Protectors CP31, CP31D, CP32D

■ ●

Dimensions, mm CP31

Front mounting type 12

CP31/W

With auxiliary switch 12

27.5

Terminal M4

Mounting rail width 35mm IEC standard

ON

46 60 64

54

27.5

Terminal M4

ON

46 60 64

54

27.5

Terminal M4

ON

CP31/X

Rail mounting type

OFF

OFF

5

OFF

21

max 6.5

8 25

21

8 25

65

10

max 6.5 Auxiliary terminal M3.5

3.5 (TH35-7.5AL) 11 (TH35-15AL)

54

Mounting rail length: 900mm Type

7

7

12

ø4.5

12

ø4.5

2-M4 (ø5)

65

Panel drilling

54

Panel drilling

21

max 6.5

55 65

2-M4 (ø5)

Material

Mounting pitch (Screw size)

TH35-7.5AL Aluminium TH35-15AL Aluminium

Mass: Approx. 100g

200mm (M5) 400mm (M5)

Clamp TS-XT

CP31D

Front mounting/Rail mounting type 27.5

Terminal M4

12

27.5

OFF

5

5 21

max 6.5

21

max 6.5

8 25

65

65 3.5 (TH35-7.5AL) 11 (TH35-15AL)

Auxiliary terminal M3.5 Mounting hole for front mounting

25

9

max. 6.5

Aux.swich 60

5

54 7

7

R2 or less

12

ø4.5

12

ø4.5

2-M4 (ø5)

Panel drilling

2-M4 (ø5)

Panel drilling 2-ø4 Panel cutting

Mass: Approx. 100g

CP32D

Front mounting/Rail mounting type Mounting rail width 35mm IEC standard 27.5

25

Size of conductors

Terminal M4

Mounting rail width 35mm IEC standard 27.5

21 max.9

25

65

10

55 65

max.9 Auxiliary M3.5

3.5 (TH35-7.5AL) 11 (TH35-15AL)

Mounting hole for front mounting C L

ø4.5

7

54

CL

7

21

25 50

3.5 (TH35-7.5AL) 11 (TH35-15AL)

2-M4 (ø5)

Panel drilling

Main terminal M4

Auxiliary terminal M3.5

Connectable wire sizes

1.25–5.5mm2 1.25–2mm2

Max. width of applicable crimp terminal

9.8mm (R1.25–4 to R5.5–4)

6.8mm (R2–3.5)

Tightening torque

1.0–1.3N·m

0.8–0.9N·m

Note: * Terminal screws are the self-lifting to facilitate wiring.

ø4.5 37

Type of terminal Terminal screw*

54

25 50

5

5

5

54

46 64

54

Terminal M4

08

CP32D/W

With auxiliary switch

46 64

25

47 62

C L

25

4

25.5

54

Mounting hole for front mounting

54

46 60 64

54

46 64

ON

OFF

3.5 (TH35-7.5AL) 11 (TH35-15AL)

Panel

Terminal M3

(25.5)

Mounting rail width 35mm IEC standard

ON

OFF

25

CP31, CP31D

Flush mounting type

Terminal M4

Mounting rail width 35mm IEC standard

ON

54

46 62 70

12

CP31D/W

With auxiliary switch

(47)

Ordering information Specify the following: 1. Type number ■

37 Panel drilling

2-M4 (ø5)

Mass: Approx. 200g

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice

08/7


Circuit Protectors CP31P, 32P, 33P

CP-P circuit protectors 250V AC 0.3A to 25A 65V DC 0.3A to 25A ■ Description CP-P circuit protectors are ideal for electronic circuit protection. The space required per pole is approximately 30% less than that for CP-E models allowing significant space savings. Application at any one of 12 rated currents in the range 0.3A to 25A is possible. CP-P circuit protectors have been approved by and TÜV Standards. ■ Features • The mounting space is approximately 30% less than that required with CP-E models, and the width per pole has been reduced by approximately 15%. • Conforms to IEC Standards. (Conforms to CE markings.) • and TÜV approved. • Operated with an easy-to-use toggle handle. • Male tab soldering, and right angle terminals are available. ■ Standards (File No.E96846) TÜV (IEC)(R9750278) ■ Accessories ● Auxiliary switch (Type W) This switch is used for indicator lamp or control circuit. ● Alarm switch (Type K) This switch can be connected to a warning lamp or buzzer to indicate when the circuit protector has been tripped.

Auxiliary and alarm switches for low level circuit are also available on request. (Type W1, K1)

CP31P

CP33P

KKD09-083

CP31P-R

KKD09-099

AF99-297

Specifications

Type

CP31P

CP32P

CP33P

CP31P-R

Pole

1-pole

2-pole

3-pole

1-pole

Rated insulation voltage (Ui)

250V AC 50/60Hz, 65V DC

Rated operational voltage (Ue)

240V AC, 60V DC

Rated current

0.3, 0.5, 0.75, 1, 2, 3, 5, 7.5, 10, 15, 20, 25A

Rated breaking capacity

1000A at 240V AC 1000A at 60V DC

Operating characteristic

Long time delay, Medium time delay Short time delay, Instantaneous tripping

Tripping mechanism

Hydraulic-magnetic

Ambient temperature

-10˚C to +60˚C

Electrical durability

10000 operations

Terminals

Tab Soldering

Main circuit Auxiliary circuit

Right angle Right angle

Accessories Auxiliary switch (W, W1) Available Alarm switch (K, K1) Available Mass (Approx.)

Main contact

Ratings of auxiliary and alarm switches

CP32P

KKD09-086

40g

Auxiliary switch

85g

130g

40g

Alarm switch

ON

Standard type (Type W, K) 250V AC

Resistive load: Inductive load:

3A 2A

125V AC

Resistive load: Inductive load:

3A 2A

30V DC

Resistive load: Inductive load:

3A 2A

Minimum permissible load

NO NC

C

OFF

C

NO NC

TRIP C

NO NC C

NO NC

For low level circuit (Type W1, K1) 24V DC 12V DC 6V DC

08/8

1mA 2mA 5mA

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice


Circuit Protectors CP31P, 32P, 33P

Versions Operating characteristic

CP31P (1-pole) Type

CP32P (2-pole) Type

CP33P (3-pole) Type

Applied circuit AC

Long time Medium time Short time Instantaneous

CP31PS/ ■ CP31PM/ ■ CP31PF/ ■ CP31PI/ ■

CP32PS/ ■ CP32PM/ ■ CP32PF/ ■ CP32PI/ ■

CP33PS/ ■ CP33PM/ ■ CP33PF/ ■ CP33PI/ ■

Applied circuit DC

Long time Medium time Short time Instantaneous

CP31PS/ DC■ CP31PM/ DC■ CP31PF/ DC■ CP31PI/ DC■

CP32PS/ DC■ CP32PM/ DC■ CP32PF/ DC■ CP32PI/ DC■

CP33PS/ DC■ CP33PM/ DC■ CP33PF/ DC■ CP33PI/ DC■

With standard auxiliary switch

Long time Medium time Short time Instantaneous

CP31PS/ W■ CP31PM/ W■ CP31PF/ W■ CP31PI/ W■

CP32PS/ W■ CP32PM/ W■ CP32PF/ W■ CP32PI/ W■

CP33PS/ W■ CP33PM/ W■ CP33PF/ W■ CP33PI/ W■

Applied circuit DC

Long time Medium time Short time Instantaneous

CP31PS/ WDC■ CP31PM/ WDC■ CP31PF/ WDC■ CP31PI/ WDC■

CP32PS/ WDC■ CP32PM/ WDC■ CP32PF/ WDC■ CP32PI/ WDC■

CP33PS/ WDC■ CP33PM/ WDC■ CP33PF/ WDC■ CP33PI/ WDC■

With standard alarm switch

Long time Medium time Short time Instantaneous

CP31PS/ K■ CP31PM/ K■ CP31PF/ K■ CP31PI/ K■

CP32PS/ K■ CP32PM/ K■ CP32PF/ K■ CP32PI/ K■

CP33PS/ K■ CP33PM/ K■ CP33PF/ K■ CP33PI/ K■

Applied circuit DC

Long time Medium time Short time Instantaneous

CP31PS/ KDC■ CP31PM/ KDC■ CP31PF/ KDC■ CP31PI/ KDC■

CP32PS/ KDC■ CP32PM/ KDC■ CP32PF/ KDC■ CP32PI/ KDC■

CP33PS/ KDC■ CP33PM/ KDC■ CP33PF/ KDC■ CP33PI/ KDC■

With auxiliary switch for low level circuit

Long time Medium time Short time Instantaneous

CP31PS/ W1■ CP31PM/ W1■ CP31PF/ W1■ CP31PI/ W1■

CP32PS/ W1■ CP32PM/ W1■ CP32PF/ W1■ CP32PI/ W1■

CP33PS/ W1■ CP33PM/ W1■ CP33PF/ W1■ CP33PI/ W1■

Applied circuit DC

Long time Medium time Short time Instantaneous

CP31PS/ W1DC■ CP31PM/ W1DC■ CP31PF/ W1DC■ CP31PI/ W1DC■

CP32PS/ W1DC■ CP32PM/ W1DC■ CP32PF/ W1DC■ CP32PI/ W1DC■

CP33PS/ W1DC■ CP33PM/ W1DC■ CP33PF/ W1DC■ CP33PI/ W1DC■

With alarm switch for low level circuit

Long time Medium time Short time Instantaneous

CP31PS/ K1■ CP31PM/ K1■ CP31PF/ K1■ CP31PI/ K1■

CP32PS/ K1■ CP32PM/ K1■ CP32PF/ K1■ CP32PI/ K1■

CP33PS/ K1■ CP33PM/ K1■ CP33PF/ K1■ CP33PI/ K1■

Applied circuit DC

Long time Medium time Short time Instantaneous

CP31PS/ K1DC■ CP31PM/ K1DC■ CP31PF/ K1DC■ CP31PI/ K1DC■

CP32PS/ K1DC■ CP32PM/ K1DC■ CP32PF/ K1DC■ CP32PI/ K1DC■

CP33PS/ K1DC■ CP33PM/ K1DC■ CP33PF/ K1DC■ CP33PI/ K1DC■

Notes :

08

Enter the rated current in the mark of the type number. 0.3A: 0.3, 0.5A: 0.5 ------ 25A: 25 ■ Enter the main circuit terminal in the ■ mark.

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice

08/9


Circuit Protectors CP31P, 32P, 33P

Type number nomenclature CP3 1 P M / 0.3 W DC

P

Basic type

Main circuit terminal Blank: Male tab terminal P: Soldering terminal R: Right angle terminal

Number of poles 1: 1-pole 2: 2-pole 3: 3-pole

Applied circuit Blank: AC DC: DC circuit

Operating characteristics S: Long time delay tripping M: Medium time delay tripping F: Short time delay tripping I: Instantaneous Rated current 0.3: 0.3A 0.5: 0.5A 0.75: 0.75A 1: 1A

2: 2A 3: 3A 5: 5A 7.5: 7.5A

10: 15: 20: 25:

Accessories Blank: Without accessory W: With standard auxiliary switch K: With standard alarm switch W1: With auxiliary switch for low level circuit K1: With alarm switch for low level circuit 10A 15A 20A 25A

Characteristic curves AC circuit

Ambient temperature compensation

Medium time delay (M) at 25˚C

1000

100

100

Max. value 10 Operating time (sec.)

Operating time (sec.)

10

1

Min. value .1

.01

.001

.1

.001

100 200 300 400 500 600 700 800 9001000 Multiple of rated current (%)

100

10

10

Max. value

.01

Operating time (sec.)

Operating time (sec.)

60 40

-10

0

10

20 25 30

40

50

60

Ambient temp. (˚C)

100 200 300 400 500 600 700 800 9001000

1

Multiple of rated current (%)

Max. value

.1

.01

Min. value 100 200 300 400 500 600 700 800 9001000

at 25˚C

1000

100

.1

08/10

Ref. temp.: 25˚C

100 80

Instantaneous (I) at 25˚C

1000

.001

Min. value

200

Multiple of rated current (%)

Short time delay (F)

1

Max. value

1

.01

300

at 25˚C

1000

Scale factor of operating time (%)

Long time delay (S)

Min. value .001

100 200 300 400 500 600 700 800 9001000 Multiple of rated current (%)

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice


Circuit Protectors CP31P, 32P, 33P

Characteristic curves

DC circuit Long time delay (S)

Medium time delay (M) at 25˚C

1000

100

100

Max. value

1

.1

.01

Min. value

1

.1

Multiple of rated current (%)

Instantaneous (I) at 25˚C

1000

100

100

10

10

Max. value

.1

.01

Min. value 100 200 300 400 500 600 700 800 9001000 Multiple of rated current (%)

at 25˚C

1000

Operating time (sec.)

Operating time (sec.)

100 200 300 400 500 600 700 800 9001000 Multiple of rated current (%)

Short time delay (F)

.001

Min. value

.01

.001

100 200 300 400 500 600 700 800 9001000

1

Max. value

10

Operating time (sec.)

Operating time (sec.)

10

.001

at 25˚C

1000

1

Max. value .1

.01

Min. value .001

100 200 300 400 500 600 700 800 9001000 Multiple of rated current (%)

08

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice

08/11


Circuit Protectors CP31P, 32P, 33P

Dimensions, mm 1-pole

2-pole

3-pole

32.6 max.

16.4max.

49 max.

ø13.6

32

ø13.6

20

20

20

32

ø13.6

32

16 M3 Depth 4.6

M3 Depth 4.6

With auxiliary or alarm switch

Series trip

Aux. terminal (for aux. switch) Thickness: 1 Width: 2.8 Main terminal Thickness: 0.8 Width: 6.3 Aux. terminal (for alarm) Thickness: 1 Width: 2.8

Aux. terminal Thickness: 1, width: 2.8

Main terminal Thickness: 0.8 Width: 6.3

View from back

View from back

View from back

Series trip

With auxiliary or alarm switch 3.5

16.9

50

7.8

3.5

50 8

3

15.4

35

35

P

LOAD

8.7

LOAD

38

1-pole 2-ø4±0.2

3-pole 6-ø4±0.2

4-ø4±0.2 Line side

ø14

+0.4 0

ø14

+0.4 0

32±0.2

32±0.2

Line side

20±0.2

20±0.2

42

2-pole

Line side

32±0.2

38 5

42

ø14

+0.4 0

Load side

Load side 16±0.2

08/12

3

LINE

P

Load side

16.9

8

LINE

Panel drilling

42

42

42

Main terminal Thickness: 0.8 Width: 6.3

42

Aux. terminal Thickness: 1 Width: 2.8

Main terminal Thickness: 0.8 Width: 6.3

With auxiliary or alarm switch

20±0.2

Main terminal Thickness: 0.8 Width: 6.3

Series trip

With auxiliary or alarm switch

42

Main terminal Thickness: 0.8, width: 6.3

16

M3 Depth 4.6

42

Series trip

16

16±0.2 16±0.2

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice


Circuit Protectors CP31P, 32P, 33P

Dimensions, mm 1-pole

Soldering terminal (With auxiliary terminal)

3.4

20

32

42

13.6

2.8

7.9 15.4

ø13.6

LINE

8.7

35.2

49 max.

ø13.6

ø13.6

3

3-pole

32.6 max.

16.4 max.

16.9 Main terminal Thickness: 0.8

2-pole

LOAD

16

38

M3 Depth 4.6

M3 Depth 4.6

42

4

43.6

16 M3 Depth 4.6

12.5 min.

5.1

Printed board 1.2

8

1.2

5

16

Panel drilling (1-pole) 5.1

35.2

3.4

1 2.85

8.7

15.4

0.5

1.25

7.9

Aux. terminal

1.2

5

4-ø1.9

Right angle terminal (With auxiliary terminal)

16.4 max. 0.8

16.9

Main terminal Thickness: 0.8

ø13.6

3

3.4

Bracket Not suppled. Prease prepare it on customer's side.

4

Panel drilling

08

6.25 12.5

32

1.2

20

7.6

42

13.6

9.6 15.2

35.2

1.2

12.5 LINE

9-ø1.9 45.4

LOAD

38

Handle center

42

Aux. terminal (Enlarged)

5

13.6

7.6 0.8 4

Aux. terminal Thickness: 0.5

1.2 5

15.2 35.2

0.5 0.8 4

1.2

9.6

45.4 A

A 1.2 50.4

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice

08/13


Circuit Protectors CP51B, 52B, 53B

50A frame size circuit protectors 250V AC 0.3A to 50A 65V DC 0.3A to 50A Features • Available with ratings from 0.3A to 50A. • Conforms to IEC Standards. (Conforms to CE markings.) • and TÜV approved. • Rated breaking capacity of 1,500A at 240V AC. • Stud terminals used. ■ Standards (File No.E96846) TÜV (IEC)(R9750278) ■ Accessories ● Auxiliary switch (Type W) This switch is used for ON-OFF lamp indicator or control circuit. ● Alarm switch (Type K) This switch can be connected to a warning lamp or buzzer to indicate when the circuit protector has been tripped. ■

Auxiliary and alarm switch for low level circuit are also available on request. (Type W1, K1)

Ratings of auxiliary and alarm switches

CP51B

CP52B

KKD09-084

CP53B

KKD09-092

KKD09-096

Specifications

Type

CP51B

CP52B

CP53B

Pole

1-pole

2-pole

3-pole

Rated insulation voltage (Ui)

250V AC 50/60Hz, 65V DC

Rated operational voltage (Ue)

240V AC, 60V DC

Rated current

0.3, 0.5, 0.75, 1, 2, 3, 5, 7.5, 10, 15, 20, 25, 30, 40, 50A

Rated breaking capacity

1500A at 240V AC 1000A at 60V DC

Operating characteristic

Long time delay, Medium time delay Short time delay, Instantaneous tripping

Tripping mechanism

Hydraulic-magnetic

Standard type (Type W, K) Ambient temperature

-10˚C to +60˚C

250V AC

Resistive load: Inductive load:

3A 2A

Electrical durability

10000 operations

125V AC

Resistive load: Inductive load:

3A 2A

Terminals

Main circuit Auxiliary circuit

Round stud Soldering

30V DC

Resistive load: Inductive load:

3A 2A

Accessories

Auxiliary switch (W, W1) Alarm switch (K, K1)

Available Available

Minimum permissible load

Mass (Approx.)

80g

180g

280g

Low level circuit (Type W1, K1) 24V DC 12V DC 6V DC

1mA 2mA 5mA

Main contact

Auxiliary switch/W

Alarm switch/K

ON

NO NC

C

OFF

C

NO NC

TRIP C

NO NC C

08/14

NO NC

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice


Circuit Protectors CP51B, 52B, 53B

â–

Versions Operating characteristic

CP51B (1-pole) Type

CP52B (2-pole) Type

CP53B (3-pole) Type

Applied circuit AC

Long time Medium time Short time Instantaneous

CP51BS/ CP51BM/ CP51BF/ CP51BI/

CP52BS/ CP52BM/ CP52BF/ CP52BI/

CP53BS/ CP53BM/ CP53BF/ CP53BI/

Applied circuit DC

Long time Medium time Short time Instantaneous

CP51BS/ DC CP51BM/ DC CP51BF/ DC CP51BI/ DC

CP52BS/ DC CP52BM/ DC CP52BF/ DC CP52BI/ DC

CP53BS/ DC CP53BM/ DC CP53BF/ DC CP53BI/ DC

With standard auxiliary switch

Long time Medium time Short time Instantaneous

CP51BS/ W CP51BM/ W CP51BF/ W CP51BI/ W

CP52BS/ W CP52BM/ W CP52BF/ W CP52BI/ W

CP53BS/ W CP53BM/ W CP53BF/ W CP53BI/ W

Applied circuit DC

Long time Medium time Short time Instantaneous

CP51BS/ WDC CP51BM/ WDC CP51BF/ WDC CP51BI/ WDC

CP52BS/ WDC CP52BM/ WDC CP52BF/ WDC CP52BI/ WDC

CP53BS/ WDC CP53BM/ WDC CP53BF/ WDC CP53BI/ WDC

With standard alarm switch

Long time Medium time Short time Instantaneous

CP51BS/ K CP51BM/ K CP51BF/ K CP51BI/ K

CP52BS/ K CP52BM/ K CP52BF/ K CP52BI/ K

CP53BS/ K CP53BM/ K CP53BF/ K CP53BI/ K

Applied circuit DC

Long time Medium time Short time Instantaneous

CP51BS/ KDC CP51BM/ KDC CP51BF/ KDC CP51BI/ KDC

CP52BS/ KDC CP52BM/ KDC CP52BF/ KDC CP52BI/ KDC

CP53BS/ KDC CP53BM/ KDC CP53BF/ KDC CP53BI/ KDC

With auxiliary switch for low level circuit

Long time Medium time Short time Instantaneous

CP51BS/ W1 CP51BM/ W1 CP51BF/ W1 CP51BI/ W1

CP52BS/ W1 CP52BM/ W1 CP52BF/ W1 CP52BI/ W1

CP53BS/ W1 CP53BM/ W1 CP53BF/ W1 CP53BI/ W1

Applied circuit DC

Long time Medium time Short time Instantaneous

CP51BS/ W1DC CP51BM/ W1DC CP51BF/ W1DC CP51BI/ W1DC

CP52BS/ W1DC CP52BM/ W1DC CP52BF/ W1DC CP52BI/ W1DC

CP53BS/ W1DC CP53BM/ W1DC CP53BF/ W1DC CP53BI/ W1DC

With alarm switch for low level circuit

Long time Medium time Short time Instantaneous

CP51BS/ K1 CP51BM/ K1 CP51BF/ K1 CP51BI/ K1

CP52BS/ K1 CP52BM/ K1 CP52BF/ K1 CP52BI/ K1

CP53BS/ K1 CP53BM/ K1 CP53BF/ K1 CP53BI/ K1

Applied circuit DC

Long time Medium time Short time Instantaneous

CP51BS/ K1DC CP51BM/ K1DC CP51BF/ K1DC CP51BI/ K1DC

CP52BS/ K1DC CP52BM/ K1DC CP52BF/ K1DC CP52BI/ K1DC

CP53BS/ K1DC CP53BM/ K1DC CP53BF/ K1DC CP53BI/ K1DC

Note :

Enter the rated current in the

08

mark of the type number. 0.3A: 0.3, 0.5A: 0.5 ------ 50A: 50

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice

08/15


Circuit Protectors CP51B, 52B, 53B

Type number nomenclature CP5 1 B M / 0.3 W DC

Basic type CP5■B

Applied circuit Blank: AC DC: DC circuit

Number of poles 1: 1-pole 2: 2-pole 3: 3-pole

Accessories Blank: Without accessory W: With standard auxiliary switch K: With standard alarm switch W1: With auxiliary switch for low level circuit K1: With alarm switch for low level circuit

Operating characteristics S: Long time delay tripping M: Medium time delay tripping F: Short time delay tripping I: Instantaneous Rated current 0.3: 0.3A 0.5: 0.5A 0.75:0.75A 1: 1A

2: 3: 5: 7.5:

2A 3A 5A 7.5A

10: 15: 20: 25:

10A 15A 20A 25A

30: 30A 40: 40A 50: 50A

Characteristic curves AC circuit

Ambient temperature compensation

Medium time delay (M) at 25˚C

1000

1000

100

100

Max. value

Operating time (sec.)

Operating time (sec.)

1

.1

Min. value .01

.001

1

.1

.01

.001

100 200 300 400 500 600 700 800 9001000 Multiple of rated current (%)

Ref. temp.: 25˚C

100 80 60 40

-10

0

10

20 25 30

40

50

60

Ambient temp. (˚C)

100 200 300 400 500 600 700 800 9001000

Instantaneous (I) at 25˚C

1000

10

10

.1

.01

Operating time (sec.)

100

Max. value

at 25˚C

1000

100

1

Min. value

200

Multiple of rated current (%)

Short time delay (F)

Operating time (sec.)

Max. value

10

10

300

at 25˚C

Scale factor of operating time (%)

Long time delay (S)

1

.1

Max. value

.01

Min. value Min. value .001

100 200 300 400 500 600 700 800 9001000 Multiple of rated current (%)

08/16

.001

100 200 300 400 500 600 700 800 9001000 Multiple of rated current (%)

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice


Circuit Protectors CP51B, 52B, 53B

Characteristic curves DC circuit

Long time delay (S)

Medium time delay (M) at 25˚C

1000

at 25˚C

1000

100

100

Max. value Operating time (sec.)

10

1

.1

.01

.001

Min. value

Short time delay (F)

Operating time (sec.)

.1

.01

100 200 300 400 500 600 700 800 9001000 Multiple of rated current (%)

100

10

10

Max. value

.1

at 25˚C

1000

100

.01

Min. value

Instantaneous (I) at 25˚C

1000

1

Max. value

1

.001

100 200 300 400 500 600 700 800 9001000 Multiple of rated current (%)

Operating time (sec.)

Operating time (sec.)

10

1

Max. value .1

.01

Min. value Min. value

.001

100 200 300 400 500 600 700 800 9001000 Multiple of rated current (%)

.001

100 200 300 400 500 600 700 800 9001000 Multiple of rated current (%)

08

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice

08/17


Circuit Protectors CP51B, 52B, 53B

Dimensions, mm 1-pole

2-pole

57.4 max.

38.2 max. 19

19

19

52.5

52.5

52.5

4.45

19.1max.

4.45

3-pole

4.45

M3 Depth 5

M3 Depth 5

With auxiliary or alarm switch

With auxiliary or alarm switch

With auxiliary or alarm switch

Aux. terminal Thickness: 1 Width: 2.8

Aux. terminal Thickness: 1 Width: 2.8

Series trip

Aux. terminal (for aux. switch) Thickness: 1 Width: 2.8

63.5

63.5

View from back

View from back

View from back

Series trip

With auxiliary or alarm switch

65.5 18.5

Aux. terminal (for alarm switch) Thickness: 1, width: 2.8

Series trip

63.5

Series trip

M3 Depth 5

71.5

20.9 18.5

47

47

20.9 3.5

4-ø4±0.2

18.3

+0.4 0

+0.4 0

36.9

52.5±0.2

Load side

57.6

6-ø4±0.2

±0.2

19

+0.4 0 ±0.2

19

Line side

52.5±0.2

38.4

4.35

4.35 +0.4 0

52.5±0.2

36.9

08/18

Load side

6

3-pole

19±0.2

36.9

4.35 +0.4 0

+0.4 19.2 0

5

2-pole Line side

Line side

18.3

8.7 18.3

M5 Stud

1-pole

2-ø4±0.2

17 49.5

49.5

M5 Stud

Panel drilling

P

P

15.4

18.3

7

7

3.5

Load side

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice


Circuit Protectors CP31E, 32E, 33E, 34E CP31V, 32V, 33V, 34V

CP-E and CP-V circuit protectors 250V AC 0.05A to 30A 65V DC 0.05A to 30A Description CP-E, CP-V circuit protectors have been specially developed for computers, communication equipment and peripheral applications. In these situations power irregularities can lead to serious and expensive damage, and reliable protective equipment is required. FUJI circuit protectors meet this need. These protectors are available with ratings from 50mA to 30A. They are widely used in FA, office machinery, communication equipment and industrial computer-controlled equipment. They are also suitable for extremely severe service since they can withstand mechanical shocks up to 981m/s2. ■ Features • Available in instantaneous, short time, medium time and long time delay types, thus making them suitable for a wide range of electronic applications. • Also available in types having inertia delay characteristics. These do not trip due to inrush current. • For internal circuits, series trip, shunt trip, relay trip and switch types are available. • Circuit protectors with an auxiliary and alarm switch are also available. • Single pole to 3-pole CP types can be operated with a single handle. Handle holes are easily made in panels. • Widths down to 19mm. ■ Standards : CP-E, CP-V (File No. E96846), (File No. E83461 for switch type), Socket CP-S (E96846SP, E83461, LR67978 (CSA C22.2 No.14)) TÜV (IEC): CP-V(R50064785) ■ Accessories ● Auxiliary switch (Type W) This switch is used for indicator lamp or control circuit. ● Alarm switch (Type K) This switch can be connected to a warning lamp or buzzer to indicate when the circuit protector has been tripped. ■

Auxiliary (W1) and alarm (K1) switch for low level circuit are also available on request.

Socket CP-S2 SM-1393

CP31E with socket ■

SM-1376

SM-1382

CP32E Rail mounting

CP31V

Specifications

Type

CP31E, V

CP32E, V

CP33E, V

CP34E, V

Pole Rated insulation voltage (Ui) Rated operational voltage (Ue) Rated current

1-pole 2-pole 3-pole 4-pole 250V AC 50/60Hz, 65V DC 250V AC 50/60Hz, 60V DC 0.05, 0.1, 0.25, 0.5, 0.75, 1, 2, 2.5, 3, 5, 7.5 10, 15, 20, 25, 30A Rated breaking capacity 1000A at 250V AC 1000A at 60V DC Operating characteristic Long time delay, Medium time delay Short time delay, Instantaneous tripping Tripping mechanism Hydraulic-magnetic Ambient temperature –10˚C to +60˚C Electrical durability 10000 operations Terminals Main circuit Tab, screw, printed board Auxiliary circuit Tab, printed board Accessories Auxiliary switch (W, W1) Available Alarm switch (K, K1) Available Inertia delay device (D) Available Mass (Approx.) 60g 120g 180g 240g

250V AC 125V AC 60V DC 30V DC

Resistive load: 3A Inductive load: 2A Resistive load: 5A Inductive load: 3A Resistive load: 1A Inductive load: 0.5A Resistive load: 4A Inductive load: 3A

● Inertia delay device (Type D) When a circuit carrying loads such as transformers or lamps is closed, an extremely large inrush current flows. This inertia delay device is designed to prevent the circuit protector from operating erroneously due to such inrush current and to carry out an interruption within the prescribed operating characteristics in the face of an overcurrent. For instance, the following graph explains that the protector does not operate even when a pulse current of approx. 18 times (peak value) rated current with a pulse width of 8ms flows.

Inertia delay characteristics

08

12000 Scale factor of rated current (%)

Ratings of auxiliary and alarm switches

10000 With inertia delay device

8000

6000

Without inertia (for reference) delay device

4000

2000

0

1

2

3

5 6 7 8 4 Pulse time [ms]

9

10

• Scale factor of the rated current (%) Peak value of pulse current Rated current for protector

× 100

• Waveform of pulse current: Sinusoidal wave or parabolic pulse Peak value of pulse current Pulse time

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice

08/19


Circuit Protectors CP31E, 32E, 33E, 34E

Versions

Internal circuit

Operating characteristics

CP31E (1-pole) Type

CP32E (2-pole) Type

CP33E (3-pole) Type

CP34E (4-pole) Type

Series trip type

Long time Medium time Short time Instantaneous

CP31E/ CP31EM/ CP31EF/ CP31EI/

CP32E/ CP32EM/ CP32EF/ CP32EI/

CP33E/ CP33EM/ CP33EF/ CP33EI/

CP34E/ CP34EM/ CP34EF/ CP34EI/

Series trip type With inertia delay device

Long time Medium time Short time Instantaneous

CP31E/ D CP31EM/ D CP31EF/ D —

CP32E/ D CP32EM/ D CP32EF/ D —

CP33E/ D CP33EM/ D CP33EF/ D —

CP34E/ D CP34EM/ D CP34EF/ D —

Series trip type With auxiliary switch

Long time Medium time Short time Instantaneous

CP31E/ W CP31EM/ W CP31EF/ W CP31EI/ W

CP32E/ W CP32EM/ W CP32EF/ W CP32EI/ W

CP33E/ W CP33EM/ W CP33EF/ W CP33EI/ W

CP34E/ W CP34EM/ W CP34EF/ W CP34EI/ W

Series trip type With auxiliary switch and inertia delay device

Long time Medium time Short time Instantaneous

CP31E/ WD CP31EM/ WD CP31EF/ WD —

CP32E/ WD CP32EM/ WD CP32EF/ WD —

CP33E/ WD CP33EM/ WD CP33EF/ WD —

CP34E/ WD CP34EM/ WD CP34EF/ WD —

Series trip type With alarm switch

Long time Medium time Short time Instantaneous

CP31E/ K CP31EM/ K CP31EF/ K CP31EI/ K

CP32E/ K CP32EM/ K CP32EF/ K CP32EI/ K

CP33E/ K CP33EM/ K CP33EF/ K CP33EI/ K

CP34E/ K CP34EM/ K CP34EF/ K CP34EI/ K

Series trip type With alarm switch and inertia delay device

Long time Medium time Short time Instantaneous

CP31E/ KD CP31EM/ KD CP31EF/ KD —

CP32E/ KD CP32EM/ KD CP32EF/ KD —

CP33E/ KD CP33EM/ KD CP33EF/ KD —

CP34E/ KD CP34EM/ KD CP34EF/ KD —

Shunt trip type

Long time Medium time Short time Instantaneous

CP31E2/ CP31E2M/ CP31E2F/ CP31E2I/

CP32E2/ CP32E2M/ CP32E2F/ CP32E2I/

CP33E2/ CP33E2M/ CP33E2F/ CP33E2I/

CP34E2/ CP34E2M/ CP34E2F/ CP34E2I/

Shunt trip type With inertia delay device

Long time Medium time Short time Instantaneous

CP31E2/ D CP31E2M/ D CP31E2F/ D —

CP32E2/ D CP32E2M/ D CP32E2F/ D —

CP33E2/ D CP33E2M/ D CP33E2F/ D —

CP34E2/ D CP34E2M/ D CP34E2F/ D —

Relay trip type (Current trip)

Long time Medium time Short time Instantaneous

CP31E3/ CP31E3M/ CP31E3F/ CP31E3I/

CP32E3/ CP32E3M/ CP32E3F/ CP32E3I/

CP33E3/ CP33E3M/ CP33E3F/ CP33E3I/

CP34E3/ CP34E3M/ CP34E3F/ CP34E3I/

Relay trip type With inertia delay device

Long time Medium time Short time Instantaneous

CP31E3/ D CP31E3M/ D CP31E3F/ D —

CP32E3/ D CP32E3M/ D CP32E3F/ D —

CP33E3/ D CP33E3M/ D CP33E3F/ D —

CP34E3/ D CP34E3M/ D CP34E3F/ D —

Switch type

CP31E4/30

CP32E4/30

CP33E4/30

CP34E4/30

Switch type With auxiliary switch

CP31E4/30W

CP32E4/30W

CP33E4/30W

CP34E4/30W

Relay trip type (Shunt trip)

CP31E5/30

CP32E5/30

CP33E5/30

CP34E5/30

Dual coil type

Long time Medium time Short time Instantaneous

CP31E6/ CP31E6M/ CP31E6F/ CP31E6I/

CP32E6/ CP32E6M/ CP32E6F/ CP32E6I/

CP33E6/ CP33E6M/ CP33E6F/ CP33E6I/

CP34E6/ CP34E6M/ CP34E6F/ CP34E6I/

Dual coil type With inertia delay device

Long time Medium time Short time Instantaneous

CP31E6/ D CP31E6M/ D CP31E6F/ D —

CP32E6/ D CP32E6M/ D CP32E6F/ D —

CP33E6/ D CP33E6M/ D CP33E6F/ D —

CP34E6/ D CP34E6M/ D CP34E6F/ D —

Notes:

08/20

Enter the rated current in the mark of the type number. 0.05A: 0.05, 0.1A: 0.1, 0.25A: 0.25......30A: 30 • When ordering types with auxiliary switch (W1) or alarm switch (K1), add suffix to type number.

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice


Circuit Protectors CP31V, 32V, 33V, 34V

Versions

Internal circuit

Operating characteristics

CP31V (1-pole) Type

CP32V (2-pole) Type

CP33V (3-pole) Type

CP34V (4-pole) Type

Series trip type

Long time Medium time Short time Instantaneous

CP31V/ CP31VM/ CP31VF/ CP31VI/

CP32V/ CP32VM/ CP32VF/ CP32VI/

CP33V/ CP33VM/ CP33VF/ CP33VI/

CP34V/ CP34VM/ CP34VF/ CP34VI/

Series trip type With inertia delay device

Long time Medium time Short time Instantaneous

CP31V/ D CP31VM/ D CP31VF/ D —

CP32V/ D CP32VM/ D CP32VF/ D —

CP33V/ D CP33VM/ D CP33VF/ D —

CP34V/ D CP34VM/ D CP34VF/ D —

Series trip type With auxiliary switch

Long time Medium time Short time Instantaneous

CP31V/ W CP31VM/ W CP31VF/ W CP31VI/ W

CP32V/ W CP32VM/ W CP32VF/ W CP32VI/ W

CP33V/ W CP33VM/ W CP33VF/ W CP33VI/ W

CP34V/ W CP34VM/ W CP34VF/ W CP34VI/ W

Series trip type With auxiliary switch and inertia delay device

Long time Medium time Short time Instantaneous

CP31V/ WD CP31VM/ WD CP31VF/ WD —

CP32V/ WD CP32VM/ WD CP32VF/ WD —

CP33V/ WD CP33VM/ WD CP33VF/ WD —

CP34V/ WD CP34VM/ WD CP34VF/ WD —

Series trip type With alarm switch

Long time Medium time Short time Instantaneous

CP31V/ K CP31VM/ K CP31VF/ K CP31VI/ K

CP32V/ K CP32VM/ K CP32VF/ K CP32VI/ K

CP33V/ K CP33VM/ K CP33VF/ K CP33VI/ K

CP34V/ K CP34VM/ K CP34VF/ K CP34VI/ K

Series trip type With alarm switch and inertia delay device

Long time Medium time Short time Instantaneous

CP31V/ KD CP31VM/ KD CP31VF/ KD —

CP32V/ KD CP32VM/ KD CP32VF/ KD —

CP33V/ KD CP33VM/ KD CP33VF/ KD —

CP34V/ KD CP34VM/ KD CP34VF/ KD —

Shunt trip type

Long time Medium time Short time Instantaneous

CP31V2/ CP31V2M/ CP31V2F/ CP31V2I/

CP32V2/ CP32V2M/ CP32V2F/ CP32V2I/

CP33V2/ CP33V2M/ CP33V2F/ CP33V2I/

CP34V2/ CP34V2M/ CP34V2F/ CP34V2I/

Shunt trip type With inertia delay device

Long time Medium time Short time Instantaneous

CP31V2/ D CP31V2M/ D CP31V2F/ D —

CP32V2/ D CP32V2M/ D CP32V2F/ D —

CP33V2/ D CP33V2M/ D CP33V2F/ D —

CP34V2/ D CP34V2M/ D CP34V2F/ D —

Switch type

CP31V4/30

CP32V4/30

CP33V4/30

CP34V4/30

Switch type With auxiliary switch

CP31V4/30W

CP32V4/30W

CP33V4/30W

CP34V4/30W

Notes:

Enter the rated current in the mark of the type number. 0.05A: 0.05, 0.1A: 0.1, 0.25A: 0.25......30A: 30 • When ordering types with auxiliary switch (W1) or alarm switch (K1), add suffix to type number.

08

Sockets (CP3 E only)

No. of poles

Circuit protector Type

Auxiliary contact

Alarm contact

Socket Type

Terminal cover Type

1-pole

CP31E, 31E4

CP-S1

CP-T3

CP31E/ W, 31E4/ W

1NO

CP-S1A

1NC

CP-S1B

1NC

CP-S1A

1NO

CS-S1B

CP31E/K

2-pole

CP32E, 32E4

CP-S2

CP32E/W, 32E4/W

SPDT

CP-S2C

CP32E/K

SPDT

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice

AF91-566

08/21


Circuit Protectors CP31E, 32E, 33E, 34E CP31V, 32V, 33V, 34V

Type number nomenclature CP3 1 E 2 M /

Basic type CP3 E (

), CP3 V (

Rated tripping voltage (for CP3 E5 and CP3 E6 only) • Relay trip type (shunt trip type) / CP3 E5 200V, 100V, 48V, 24V AC 50/60Hz or DC • Dual coil type / CP3 E6 100V, 50V, 32V, 24V, 12V, 6V AC 50/60Hz or DC

, IEC)

Number of poles 1: 1-pole 3: 3-pole 2: 2-pole 4: 4-pole Internal circuit Blank: Series trip type 2: Shunt trip type 3: Relay trip type (Current trip) * 4: Switch type 5: Relay trip type (Shunt trip) * 6: Dual coil * * for CP3 E only Operating characteristics Blank: Long time delay M: Medium time delay F: Short time delay I: Instantaneous Rated current 0.05: 0.05A 0.1: 0.1A 0.25: 0.25A 0.5: 0.5A 0.75: 0.75A 1: 1A

2: 2.5: 3: 5: 7.5:

2A 2.5A 3A 5A 7.5A

10: 15: 20: 25: 30:

W D DC N (AC 200V)

Main terminal Blank: Tab terminal N: Screw terminal (series trip type and switch type) P: Printed board type (CP3 E only) Circuit voltage Blank: AC circuit DC: DC circuit Inertia delay device Blank: Without inertia delay device D: With inertia delay device (Except instantaneous type) 10A 15A 20A 25A 30A

Accessories Blank: Without accessories W: With standard auxiliary switch (For series and switch types) W1: With auxiliary switch for low level circuit K: With standard alarm switch (For series type) K1: With alarm switch for low level circuit

■ Ordering information Specify the following: 1. Type number (Including rated tripping voltage)

08/22

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice


Circuit Protectors CP31E, 32E, 33E, 34E CP31V, 32V, 33V, 34V

Dimensions, mm Series trip and switch types Tab terminal CP31E, CP31E4 CP31V, CP31V4

■ ●

53

7 9 11.5

3-pole

4-pole

57.5 max.

38.5 max.

φ 15

76.5 max.

φ 15

φ 15

42 26.5

LOAD

LOAD

3.3 18 max.

11.5 19.5

42

3.3 18 max.

26.5

LINE

42

6 39

*2

LINE

42

2-pole

19 max.

φ 15

*1

6 39

*2

7 9 11.5

*1

1-pole

53

19

19

M3 Depth 4

19

19

19

19

M3 Depth 4

*1 With auxiliary switch (W1), With alarm switch (K1) : 6 *2 With auxiliary switch (W1), With alarm switch (K1) : 10

Screw terminal 53 5 6

Panel drilling 18 max.

42

1-pole

3.3

2-pole

2-ø4

3-pole

4-ø4

4-ø4

4-pole

4-ø4

Line side

42 ±0.2

26.5±0.2

LINE

ø16

ø16

Load side

ø16 19 ±0.2 19 ±0.2

19 ±0.2

LOAD

R8 56.4 ±0.2

Main terminal M4 × 8 Thickness: 0.8 Width: 6.3

Shunt trip type Tab terminal

Socket for rail mounting (CP-E/Series trip and switch types)

1-pole 19

6

(78) 28

LINE

(32)

2-pole 38 19

Main terminal M4

29

21 21

LOAD

C

21

NO

20

NC

30

LOAD

Relay trip type (CP-E only) Tab terminal

21

NO

20

NC

30

LOAD

Aux. terminal M3.5

15 20

19

10 6

Circuit protector LINE

08

LINE

C

77 84 93

10

LINE

30

30

2-M4 Mounting hole

10

Mounting rail 35mm width IEC standard LOAD

Terminal arrangement Aux. terminal Thickness:0.5 Width:2.8 Main terminal Thickness:0.8 Width:6.3

Main terminal Thickness:0.8 Width:6.3 Aux. terminal Thickness:0.5 Width:2.8

Aux. terminal Thickness:0.5 Width:2.8 Main terminal Thickness:0.8 Width:6.3

Aux. terminal Thickness:0.5 Width:2.8 Main terminal Thickness:0.8 Width:6.3

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice

51

51

51

NO NC

51

Common

08/23


Circuit Protectors CP31E, 32E, 33E, 34E CP31V, 32V, 33V, 34V

■ Characteristic curves AC circuit Long time dealy (S)

Medium time delay (M) at 25˚C

1000

100

1

Min. value 0.1

10

Operating time (sec.)

Operating time (sec.)

Operating time (sec.)

Max. value

10

Max. value 1

0.1

Min. value

100

200

300

400 500

600

700

800

0.001

900 1000

Multiple of rated current (%)

1

Max. value

0.1

Min. value

100

200

300

400 500

600

700

800

900 1000

0.001

100

DC circuit Long time delay at 25˚C

1000

100

10

10

300

400

500

600

700

800

900 1000

Medium time delay (M)

at 25˚C

100

200

Multiple of rated current (%)

Multiple of rated current (%)

AC circuit Instantaneous (I) 1000

10

0.01

0.01

0.01

at 25˚C

1000

100

100

0.001

Short time delay (F) at 25˚C

1000

at 25˚C

1000

100

1

Max. value

0.1

Operating time (sec.)

Operating time (sec.)

Operating time (sec.)

Max. value

1

Min. value 0.1

Max. value 1

0.1

Min. value

0.01

0.01

0.01

10

Min. value 100 200 300 400 500 600 700 800 900 1000

0.001

Multiple of rated current (%)

1000

100

100

10

10

Multiple of rated current (%)

at 25˚C

Ambient temperature compensation

Max. value

1

0.1

Min. value

Operating time (sec.)

Operating time (sec.)

1000

300

1

0.1

Max. value

0.01

Min. value 100 200 300 400 500 600 700 800 900 1000 Multiple of rated current (%)

08/24

100 200 300 400 500 600 700 800 900 1000

Instantaneous (I) at 25˚C

0.001

0.001

Multiple of rated current (%)

DC circuit Short time delay (F)

0.01

100 200 300 400 500 600 700 800 900 1000

0.001

100 200 300 400 500 600 700 800 900 1000 Multiple of rated current (%)

Scale factor of operating time (%)

0.001

200

Ref. temp.: 25˚C 100 80 60 40

-10

0

10

20 25 30

40

50

60

Ambient temp. (˚C)

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice


Low Voltage Fuses General information

Description FUJI low voltage current-limiting fuses are designed to give protection to power supply and distribution circuits and equipment such as motor starter and semiconductors. Since they can be supplied in a variety of types and ratings any circuit capacities can be accurately matched. FUJI current-limiting fuses have a high interrupting capacity and will prevent thermal and mechanical damage from heavy short circuits. ■

AF97-635,634

BLC, CR and CS type Super Rapid Fuses These fuses are used exclusively for the protection of semiconductors, thyristors and silicon diodes. Since their total clearing I2t is very small protective coordination with semi-conductors is very easily carried out. ■ Rated current: BLC type: 12 – 140 Amps CR type: 30 – 600 Amps CS type: 40 – 4700 Amps For further information see page 08/31.

AF97-635,634

AFaC and BaC type current-limiting fuses These fuses have a high interrupting capacity of 100kA at 600V AC or DC and are suitable for power and control circuits. The fuse is a plug-in type, and it can easily be replaced by removing a screw cap. ■ Rated current: 3 – 400 Amps For further information see page 08/26.

Quick selection table

Series AFaC

Voltage

Interrupting capacity rms sym (kA) 20 35 50 100

600V AC DC 3 to 100 Amps

BaC

(CS fuse: Typical value)

Application 200 General use

125 to 200 Amps 250 to 400 Amps

FCF

500V AC

1 to 60 Amps

FCK

500V AC

3 to 600 Amps

BLC

550V AC

12 to 140 Amps

CR2L(S)

250V AC

10 to 600 Amps

CR6L

600V AC

20 to 600 Amps

CS5F

500V AC

40 to 1500 Amps

CS10F

1000V AC

80 to 1500 Amps

CS15F

1500V AC

450 to 1250 Amps

General use Semiconductor protection

AF97-642

08

FCF and FCK type current-limiting fuses These fuses are provided with special links with low-temperature melting characteristics, and are suitable for general power circuits because of their high interrupting capacity and good current-limiting performance. They are available in two types, a center-blade type and a solid ferrule type, with an insulated fuse body of high quality porcelain. ■ Rated current: 1 – 600 Amps For further information see page 08/29.

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice

08/25


Low Voltage Fuses AFaC and BaC types

AFaC and BaC type currentlimiting fuses 600V AC/DC, 3–400 Amps ■ Description The AFaC and BaC type have an excellent current-limiting performance with an interrupting capacity as high as 100kA at 600V AC/DC. They are suitable for power circuits and control circuit applications including general power cubicles, distribution equipment, motor starters, load centers and control centers. The fuse assembly comprises base, screw cap, fuse link and adapter ring. The universal surface mounting terminals are provided with screws while the rear connection type are supplied with stud bolts. The fuse link can easily and safely be replaced by simply removing a screw cap. The diameter of the solid ferrule fuse link varies according to the rated current. The higher the rating, the greater the diameter. As a safety feature the screw cap can only be tightened when the fuse link matches with the adapter ring located inside the base. This prevents the cap from being tightened even when fuse ■

AF97-634

O-1299

AFaC-60 Rear connection type Cap

BaC-100

60A 200A Surface connection type Indicating winndow Screw cap

Insulating plate Mounting plate Base Front bushing

Faucet screw Fuse-Iink

Rear bushing

Terminal (load) Adapter ring Terminal (Iine)

Contact spring Beae

Thickness of mounting plate: 3.2mm or less

link with larger ratings is inserted. The operating blown indication tip can be observed through the screw cap window. The tip color indicates the current rating – for instance, pink indicates 3A and red 10A. The tip is ejected to show that the fuse has blown. Both the base and the screw cap are made from a high class

porcelain insulating material to ensure trouble-free operation. The fuse can be replaced without isolating the circuit. Since the fuse link is housed in a highly reliable porcelain barrel it is strong mechanically and thermally with no danger of explosion or production of noxious gases when blown.

Components of AFaC and BaC type

Parts

FA776

Rated current (A)

SD-39

Fuse-link

Screw cap

SD-39

Type

Color of indicator

Type

Base Surface connection Type

3 5 10 15 20 30

BLA003 BLA005 BLA010 BLA015 BLA020 BLA030

Pink Brown Red Gray Blue Violet

Pa30

AFa30

40 60 75 100 125 150 200 250 300 400

BLA040 BLA060 BLA075 BLA100 BLA125 BLA150 BLA200 BLA250 BLA300 BLA400

Black Light red Silver Red Yellow Light red Blue Green White Black

Pa60

Adapter ring Type

Color of adapter ring

Ba30

R3 R5 R10 R15 R20 —

Pink Brown Red Gray Blue —

AFa60

Ba60

Pa100

AFa100

Ba100

Pa200

AFa200

Ba200

Pa400

AFa400

Ba400

R40 — R75 — R125 R150 — R250 R300 —

Black — Silver — Yellow Light red — Green White —

Minimum ordering quantity • Fuse-link BLA003 to 030 BLA 040, 060 BLA 075 to 200 BLA 250 to 400

100 pcs. 20 10 5

• Base

• Screw cap Pa30 Pa60 Pa100 Pa200 Pa400

100 pcs. 50 10 5 1

• Adapter ring

08/26

SD-63

SDO 0091M

AFa30 Ba30 AFa60 Ba60 AFa100 Ba100 AFa200 Ba200 AFa400 Ba400 R3 to 20, R75 R40, R125 to 300

Rear connection Type

100 pcs. 50 10 5 1 100 pcs. 50

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice


Low Voltage Fuses AFaC and BaC types

Specifications

Fuse-link Type

Rated current (A)

Rated voltage

Interrupting capacity (kA)

Max. interrupting I2t (Amp2 x sec.)

BLA003 BLA005 BLA010

3 5 10

600V AC DC

100

BLA015 BLA020 BLA030

15 20 30

100

750 1.3 5

× 103 × 103

BLA040 BLA060

40 60

100

9.2 27

× 103 × 103

BLA075 BLA100

75 100

100

70 100

× 103 × 103

BLA125 BLA150 BLA200

125 150 200

50

290 390 500

× 103 × 103 × 103

BLA250 BLA300 BLA400

250 300 400

20

1800 2200 3000

× 103 × 103 × 103

28 110 500

Mounting on steel panel To mount a rear connection base Ba on a steel panel, an insulting plate and some bushings are used. Kits for 30, 60, 100, 200 and 400A base are available. Please specify your base type when ordering. Two front bushings are used with 100, 200 and 400A base only. Example: Insulating plate and bushings for Ba30 ■

Ordering information Specify the following: 1. Type number

Fuse-link BLA 003

Base AFa 30 Rated current Ex. 003 : 3 Amps 075 : 75 Amps 200 : 200 Amps Fuse-link

Frame size 30: For 3 to 30A 60: For 40, 60A 100: For 75, 100A 200: For 125, 150, 200A 400: For 250, 300, 400A Connection AFa: Surface Ba : Rear

Screw cap Pa 30 Frame size 30: For 3 to 30A 60: For 40, 60A 100: For 75, 100A 200: For 125, 150, 200A 400: For 250, 300, 400A Screw cap

Tightening tool It is recommended that fuses with ratings of over 100A be tightened with a special tool since there is the possibility of overheating if the screw cap is not adequately tightened. This exclusive use tool is sold separately.

Type

Screw cap type

Pa100H Pa200H Pa400H

Pa100 Pa200 Pa400

AF90-316

08 AF97-644

Characteristic curves

Current (A)

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice

Current-limiting characteristic

Max. Let-through current (Peak value) kA

Time

Second

Time

Minute

Permissible time-current characteristic

Minute

Melting time-current characteristic

Second

Current (A)

Available current (Sym, rms) I eff. (kA)

08/27


Low Voltage Fuses AFaC and BaC types

■ ●

Dimensions, mm Fuse-link

Type

Position of indicator

øD

B

B

B

A

A

øD

A

øD

ød

ød

3 to 30A

ød

40 to 60A

75 to 400A

Base and cap Surface connection AFaC-3 to 200 ●

Y1

Rated A current (A)

B

øD

ød

Mass (g)

BLA003 BLA005 BLA010 BLA015 BLA020 BLA030

3 5 10 15 20 30

50 50 50 50 50 50

10 10 10 10 10 10

13 13 13 13 13 13

8 8 8 10 10 14

12 12 12 12 12 12

BLA040 BLA060

40 60

50 50

10 10

27 27

16 20

47 62

BLA075 BLA100

75 100

63 63

5.4 5.4

34 34

5 8

120 120

BLA125 BLA150 BLA200

125 150 200

63 63 63

5.4 5.4 5.4

47 47 47

5 8 10

215 215 215

BLA250 BLA300 BLA400

250 300 400

63 63 63

5.4 5.4 5.4

61 61 61

5 8 10

380 380 380

Panel drilling

Y2

D A

D

E

D1

D1

K

M1 H

M C

G

L (Load)

B B1

L (Line)

Rear connection BaC-3 to 200

Type

A

B

B1

C D (max.)

AFaC-3 to 30 AFaC-40 to 60 AFaC-75 to 100 AFaC-125 to 200

34 52 67 77

42 55 46.5 59 82 51 87 125 71 107 150 73

24 34 40 51

D1 øE

G H (max.)

K

L

M

M1

Y1

Y2

22 38 64 82

78.5 88 118 120

32 47 72 87

M5 M6 M8 M10

18 21 27.5 34

24 26 29.5 35

22 33 50 60

22 100 33.5 290 50 950 59.5 1465

5 5.5 7 7

10 10 28 28

Mass (g)

L (2-ø14)

A

45˚

45˚

Panel drilling

F

F

G

A B (max.) (max.)

C

D

E

F

Line

BaC-3 to 30 BaC-40 to 60 BaC-75 to 100 BaC-125 to 200

47 47 66 66 85.5 85.5 112 112

52 54 71 78

62 65 70 75

10 18 22 28

14 78.5 M5 22.5 87.5 M6 30 112.5 M8 39 120 M10

H

Surface connection AFaC-250 to 400

Mounting hole 4-7ø

K øL (max.)

Mass (g)

32 47 72 87

220 470 1200 2115

Mass: 4.76kg

M12×30

160

83

103 139.5 max

2-PF1/4 (2-ø26)

140 209 max

90

15

83 51

70

4-M6

103 139.5 max

Panel drilling

( ): In the case the steel plate is used.

209 max 102 max

Panel drilling

160 102 max

6(14) 7(14) 9(25) 11(25)

Rear connection BaC-250 to 400

70 117 max

Mass: 4.37kg

G H (max.)

117 max

E

Type

D Load

E

C

B K

140

140

( ) :In the case the steel plate is used PF1/4(ø13)

08/28

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice


Low Voltage Fuses FCF and FCK types

FCF, FCK type current-limiting fuses 500V AC FCF Up to 60 Amps FCK Up to 600 Amps Description FCF and FCK HRC fuses use a specially designed low-temperature melting element, a feature of 'dual element' fuses. There is no fuse deterioration due to overcurrent phenomena such as rush current at the time of motor starting and they also feature time-lag operation characteristics. They operate rapidly and positively in the face of destructive short circuit currents. Since they are current-limiting fuses with a high capacity of 50kA (FCF types: 1 – 60 Amps) they are suitable for many types of power and control circuits. The fuse link is housed in a ceramic barrel with ■

FCF series

Ordering information Specify the following: 1. Type number ■

Fuse-link

FCF2-40 to 60

Type FCF2-1 FCF2-3 FCF2-5 FCF2-10 FCF2-15 FCF2-20 FCF2-30 FCF2-40 FCF2-50 FCF2-60

Note: Minimum ordering quantity Fuse-link: 100 pcs.

0

50

Dimensions, mm Fuse-link FCF2-1 to 30

T-7

ø2

1 3 5 10 15 20 30 40 50 60

excellent thermal and mechanical characteristics and is packed in silica sand which prevents arcing. Thus there are no fears of explosion or production of noxious gases. The FCF's link end is a solid ferrule-type and available in 1 – 60 Amps ratings. The FCK is a center blade-type and available in 3 – 600 Amps ratings. The fuse links for the 75 Amps FCK and larger sizes are provided with a blown fuse indicator.

Blown fuse indicator

5

Interrupting capacity (kA)

AF97-643

FCK series fuse-link

ø1

Rated current (A)

SD-240

FCF series fuse-link

13.5

13.5

16.5

16.5

50 75

Mass: 20g

Mass: 80g

● Fuse-link FCK2-3 to 600

E

C

FCK series Interrupting capacity (kA)

Fuse-link

08 D

Rated current (A)

Type B

3 5 10 15 20 30

35

FCK2-3 FCK2-5 FCK2-10 FCK2-15 FCK2-20 FCK2-30

40 50 60

FCK2-40 FCK2-50 FCK2-60

75 100

FCK2-75 FCK2-100

125 150 200 250 300 400 500 600

FCK2-125 FCK2-150 FCK2-200 FCK2-250 FCK2-300 FCK2-400 FCK2-500 FCK2-600

B

A

Type

A

B

C

D

E

Mass (g)

FCK2-3 to 30 FCK2-40 to 60 FCK2-75, 100 FCK2-125 to 200 FCK2-250 to 400 FCK2-500, 600

50 75 95 110 120 145

15 19 25 35 50 60

ø19.8 ø24.9 ø31 ø45 ø63 ø75

13 16 20 30 40 50

66.5 96 122.5 148.5 170 205

35 95 180 470 1100 2000

Note: Minimum ordering quantity Fuse-link: 100 pcs.

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice

08/29


Low Voltage Fuses FCF and FCK types

Characteristic curves FCF type

FCK type

Melting time-current characteristic

Time

Time

Second

Minute

Minute

Melting time-current characteristic

Second

Current (A) Current (A)

Permissible time-current characteristic

Second

Time

Second

Time

Minute

Minute

Permissible time-current characteristic

Current (A)

Current (A)

Current limiting characterisitc

Max. Let-through current (Peak value) kA

Max. Let-through current (Peak value) kA

Current limiting characterisitc

Available current (Sym, rms) I eff. (kA) Available current (Sym, rms) I eff. (kA)

08/30

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice


Low Voltage Fuses BLC, CR and CS types Super Rapid Fuses

BLC, CR and CS types Super Rapid Fuses 150–1500 Volts AC 10–4700 Amps Description The FUJI BLC, CR and CS types are extremely reliable fuses which have been specially developed to provide protection for silicon diodes and thyristors and are suitable for inverters using semiconductors or transformersrectifiers. FUJI Super Rapid Fuses are designed with a very small total I 2 t value which gives them a high speed interrupting action in the face of abnormal currents. In addition the arc voltage generated at the time of interruption has a low value so that faults will not influence related electric machinery and equipment. These fuses can carry out the protection of many types of circuits rating from the semiconductor overcurrents to destructive shortcircuiting faults-i.e. when the ■

SD-36

BLC

SM-388

CR2L

SI-431

CS5F

semiconductors short or circuits fail the sound elements will be quickly isolated from the fault circuits. Features • The total clearing I 2t is small and the semiconductor circuit is completely protected. • Since the peak arc voltage at the time of interruption is low damage to other equipment does not occur. ■

SI-429

CS10F

• High interrupting capacity of 200kA at 1000V AC • The CS type is provided with a blown fuse indicator. An alarm contact block (1NO or 1NC) can also be attached. ■

UL recognized: CR2L/UL,CR2LS/UL, CR6L/UL (File No. E92312) CSA certificated: CR2LS/UL (File No. LO4000-4090) TÜV: CR2LS/UL (10-100A), CR2L/UL (150-350A) (Rep. No. E9450643E02) CR6L/UL (50-300A) (Rep. No. E9560543E02)

Specifications

Rated current (A) 12 20 23 45 75 90 120 140 30 50 75 100 125 140 150 175 200 225 260 300 325 350 400 450 500 550 600

Rated Peak voltage arc voltage (V) 550V 1550 AC 1550 1550 1380 1250 1250 1200 1200 250V Max. AC 500

Max. interrupting I2t

(Amp ×sec.)

Watt loss

Fuse-link

Rated current

2

× 103

0.09 0.27 0.39 1.8 5 11.5 33 100 0.35 0.85 2.3 4.0 6.5 7.0 9.5 13 17 22 27 38 49 60 103 140 160 200 215

Type (W) 5.1 8.5 10 19 32 38 51 59 4.0 6.0 9.0 12.0 14.0 16.0 18.0 21.0 23.0 26.0 30.0 35.0 37.0 37.0 39.0 46.0 48.0 51.0 56.0

BLC012-1 BLC020-1 BLC023-1 BLC045-1 BLC075-1 BLC090-1 BLC120-1 BLC140-1 CR2L-30 CR2L-50 CR2L-75 CR2L-100 CR2L-125 CR2L-140 CR2L-150 CR2L-175 CR2L-200 CR2L-225 CR2L-260 CR2L-300 CR2L-325 CR2L-350 CR2L-400 CR2L-450 CR2L-500 CR2L-550 CR2L-600

(A) 10 20 30 50 75 100 20 30 50 75 100

Rated Peak Max. voltage arc interrupting I2t voltage (Amp2×sec.) × 103 (V) 250V Max. 0.04 AC 500 0.17 0.35 0.85 2.3 4.0 600V Max. 0.14 AC 1200 0.35 1.8 3.0 7.0

150 200 250 300 350 400 500 600

18 30 70 95 150 200 390 700

Watt loss

Fuse-link Type

(W) 1.2 3.0 4.0 6.0 9.0 12.0 4.0 7.0 9.0 12.5 15

CR2LS-10 CR2LS-20 CR2LS-30 CR2LS-50 CR2LS-75 CR2LS-100 CR6L-20 CR6L-30 CR6L-50 CR6L-75 CR6L-100

22.0 34.0 37.0 40.0 45.0 55 60 70

CR6L-150 CR6L-200 CR6L-250 CR6L-300 CR6L-350 CR6L-400 CR6L-500 CR6L-600

08

Interrupting capacity CR2LS . 100kA at 250V AC CR6L .... 100kA at 600V AC

Interrupting capacity BLC ...... 100kA at 550V AC CR2L .... 100kA at 250V AC

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice

08/31


Low Voltage Fuses BLC, CR and CS types Super Rapid Fuses

Specifications

Rated Intercurrent rupting capacity (A) 4700 2000 3000 40 75 100 150 200 250 300 350 400 450 500 600 800 1000 1000 1200 1200 1500 1000 1200 1500 80 100 150 200 250 300 350 400 500 560 630 750 800 1000 1250 1500 450 630 900 1250 Note:

(kA) 150 at 125V AC 150 at 250V AC 200 at 500V AC

Specifications (UL-recognized, CSA certified, TÜV)

Max. Watt interrupting I2t loss

Fuse-link

× 103

Type

(Amp2×sec.)

14000

1950 5500 1 3.5 5 10 18.5 33 64 85 122 131 159 257 600 1200 843 1800 1311 3600 200 at 1800 800V AC 2500 4400 200 at 10 1000V AC 16 37 63 110 148 211 307 420 410 450 640 1259 1722 2250 3200 100 at 350 1500V AC 760 1400 3050

(W) 310

CS1F-4700

124 216 6.4 12 17 25 34 42 45 56 57 62 73 80 114 110 167 114 200 209 125 176 220 17 21 27 37 44 53 70 74 90 102 135 156 211 245 330 334 134 170 280 350

CS2F-2000 CS2F-3000 CS5F-40 CS5F-75 CS5F-100 CS5F-150 CS5F-200 CS5F-250 CS5F-300 CS5F-350 CS5F-400 CS5F-450 CS5F-500 CS5F-600 CS5F-800 CS5F-1000 CS5F-1000-P CS5F-1200 CS5F-1200-P CS5F-1500 CS8F-1000 CS8F-1200 CS8F-1500 CS10F-80 CS10F-100 CS10F-150 CS10F-200 CS10F-250 CS10F-300 CS10F-350 CS10F-400 CS10F-500 CS10F-560 CS10F-630 CS10F-750 CS10F-800-P CS10F-1000-P CS10F-1250-P CS10F-1500-C CS15F-450 CS15F-630 CS15F-900-P CS15F-1250-P

• Peak arc voltage CS1F ..... Max. 450V CS2F ..... Max. 750V CS5F ..... Max. 1000V CS8F ..... Max. 2000V CS10F ... Max. 2000V CS15F ... Less than 3000V • An alarm contact block AHX2905 (1NO) or AHX2915 (1NC) can be attached to CS type. (Sold separately) See page 08/40.

Note: UL recognized fuse In the UL recognized fuses, a fuse with a blown inidcation fuse, or a fuse both with a blown indication fuse and a precision switch is also UL recognized. Examples: CR2L-200G/UL CR2LS-30S/UL CR6L-100G/UL

Rated Rated current voltage (A) 10 20 30 50 75 100 150 200 260 350 400 450 500 550 600 20 30 50 75 100 150 200 300 Note:

Interrupting capacity

(kA) 250V AC 10 at AC 400V DC (pf: 0.8) 10 at DC (L/R: 2ms)

600V AC 100 at AC 680V DC (pf: 0.8) 10 at DC (L/R: 2ms)

100 at AC (pf: 0.8) 50 at DC (L/R: 2ms)

Max. interrupting I2t (Amp2×sec.)

× 103

Fuse-link Type

0.04 0.17 0.35 0.85 2.3 4.0

(W) 1.2 3.0 4.0 6.0 9.0 12.0

CR2LS-10/UL CR2LS-20/UL CR2LS-30/UL CR2LS-50/UL CR2LS-75/UL CR2LS-100/UL

9.5 17 27 60 103 140 160 200 215 0.14

18.0 23.0 30.0 37.0 39.0 46.0 48.0 51.0 56.0 4.0

CR2L-150/UL CR2L-200/UL CR2L-260/UL CR2L-350/UL CR2L-400/UL CR2L-450/UL CR2L-500/UL CR2L-550/UL CR2L-600/UL CR6L-20/UL

0.35

7.0

CR6L-30/UL

1.8 3.0 7.0 18

9.0 12.5 15.0 22.0

CR6L-50/UL CR6L-75/UL CR6L-100/UL CR6L-150/UL

30

34.0

CR6L-200/UL

95

40.0

CR6L-300/UL

• Peak arc voltage CR2LS, CR2L .... Max. 500V CR6L .................. Max. 1200V • The peak arc voltage is obtained by interruption caused by the listed interrupting current at rated voltage. • This indcates the values when the conductors specified in UL Standards are connected and rated current apply. • TÜV: CR2LS, 2L: Up to 350A CR6L: 50 to 300A

CR type fuse with optional accessory Fuse with blown indication fuse CR2L (S)- G ■

AF88-446

Fuse with blown indication fuse and precision switch Precision switch (SPDT) CR2L (S)- S CRX-1

precision switch AF88-445

08/32

Watt loss

AF88-442

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice


Low Voltage Fuses BLC, CR and CS types Super Rapid Fuses

Dimensions, mm BLC

D

BLC045

øD

øD

B

B

B

A

A

B

BLC075 to 140

C

BLC012, 020, 023

øD

CR2L-450 or smaller, CR2LS

E

A

ød

ød

Mounting hole a × b

ød H

Rated current (A)

BLC012-1 12 BLC020-1 20 BLC023-1 23 BLC045-1 45 BLC075-1 75 BLC090-1 90 BLC120-1 120 BLC140-1 140 Note:

A

B

50 50 50 50 63 63 63 63

10 10 10 10 6 6 6 6

øD

13 13 13 27 34 34 47 47

ød

10 14 14 20 5 8 8 8

Color of indicator

Mass (g)

Grey Yellow Violet White Silver Red Yellow Light red

12 12 12 62 120 120 120 215

The BLC type fuse link requires a holder in use. The size of the holder differs according to the fuse ratings. Select the most suitable one after referring to the Table on page 08/40. For drawings see page 08/28.

Ordering information Specify the following: 1. Type number

Type number nomenclature BLC 012-1 ■

Rated current: 12 to 140A Plug-in type super rapid fuse

CS 10F-1000

-P/ UL UL recognized (CR2L, CR2LS, CR6L) CSA certificated (CR2LS) TÜV (CR2LS, CR2L, CR6L)

Blown indicatin fuae (G type)

G

Type

F

A

Type

A

CR2L-30 CR2L-50 CR2L-75 CR2L-100 CR2L-125 CR2L-140 CR2L-150 CR2L-175 CR2L-200 CR2L-225 CR2L-260 CR2L-300 CR2L-325 CR2L-350 CR2L-400 CR2L-450 CR2LS-10 CR2LS-20 CR2LS-30 CR2LS-50 CR2LS-75 CR2LS-100 ●

B

C

D

80 58

18

80 58

E

a×b

F

21.5 37

9×11

90 1.5 26.5

20

30.5 44

9×11

90 3

85 60

25

33.5 47

11×13 93 3.2 33.5 130g

95 70

30

42

11×13 98 4

39

220g

56 42

12

18.5 34.5 6.5×8.5 78 2

25

28g

54

G

H

Mass 42g

32.5 100g

08

CR2L-500 to -600 70

84

2-fuse connected parallel

ø37

30

Mounting hole 11×13

Rated current 10 to 4700A

41.5 43 46

6L: 2F: 8F: 15F:

600V AC 250V AC 800V AC 1500V AC

98 84 Blown indication fuse (G type)

8

Rated voltage 2L, 2LS: 250V AC, 1F: 150V AC, 5F: 500V AC, 10F: 1000V AC,

46.5

28

54

31

Optional accessory (See page 08/44) G: With blown indication fuse S: With blown indication fuse and precision switch

CR: Barrel-shaped super rapid fuse CS: Cubic-shaped super rapid fuse Mass: 450g

95

Dimensions for reference only. Confirm before construction begins. Note: The dimensions of the fuses with suffix. UL are the same as those of the standard ones.

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice

08/33


Low Voltage Fuses BLC, CR and CS types Super Rapid Fuses

Dimensions, mm CR6L-20, CR6L-30, CR6L-50

CR6L-75 to 300

62

CR6L-350 to 600 84

B

H

Mountng hole 6.5×8.5

25

88 74

30

Mountng hole 11×13 Blown indication D fuse (G type)

41.5 43 46

Mountng hole a × b 23.5

ø37 54

C E

27

12

ø17.5

47

18

34.5

18.5

● B

D 46.5

28

F 8

Blown indication fuse (G type)

76

Mass: 42g Type

C A

A

A

CR6L-75 CR6L-100 CR6L-150

B

95 70

CR6L-200 107 82 CR6L-250 CR6L-300

G

2

Blown indication fuse (G type)

C

D

E

25

34

47 102 3.2 33.5 11×13 150

30

42

F

G

H

54 107 4

39

CS1F-4700 CS2F-2000, 3000

a×b

Mass (g)

11×13 246

Type

A

B

C

D

Mass (g)

CR6L-350

107

82

43

107

493

CR6L-400 CR6L-500

121

96

43

114

522

CR6L-600

121

96

47.4

114

545

CS5F-40 to 1500 CS10F-80 to 750 CS15F-450, 630

CS8F-1000, 1200, 1500 Alarm contact block

7

Alarm contat block

AHX2905(NO) AHX2915(NC)

Blown fuse indicator

Blown fuse indicator

7

7

Alarm contact block

54.5

C

C

84 max.

7

D

D

Blown fuse indicator

72

30

30

A

A

N.P.

M

B

A

A

B

51

72 2-MIO

M

Mass: 800g Voltage Type 500V

08/34

A

CS5F-40 CS5F-75 CS5F-100 CS5F-150 CS5F-200

47

CS5F-250 CS5F-300 CS5F-350

57

CS5F-400 CS5F-450 CS5F-500 CS5F-600 CS5F-800

72

CS5F-1000 CS5F-1200 CS5F-1500

72

B 47

51

51

51

C 42.5

47

54.5

54.5

(Max.)

D

Mass (g)

65.5 M8

320

70

77

77

M

M8

M10

M12

Voltage Type

A

B

C

D

M

Mass (g)

M12

1060

(Max.)

800V

CS8F-1000 CS8F-1200

72

74

54.5

84

CS8F-1500

72

82

54.5

84

M8

1150

1000V

CS10F-80 CS10F-100

47

71

42.5

65.5

M8

420

CS10F-150 CS10F-200 CS10F-250

57

74

47

70

M8

690

CS10F-300 CS10F-350 CS10F-400 CS10F-500 CS10F-630 CS10F-750

72

74

54.5

77

M10

1060

CS15F-450 CS15F-630

72

105

54.7

77

M10

1400

510

800

830 1500V

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice


Low Voltage Fuses BLC, CR and CS types Super Rapid Fuses

Dimensions, mm

CS5F-P CS10F-P, CS15F-P

Characteristic curves BLC Melting time-current characteristic 7

Minute

max.77

72

Time

72 40

5

H

N.P.

L

54.5

7

Alarm contat block

M10

ø15

Voltage

Type

H

L

Mass (g)

500V

CS5F-1000-P CS5F-1200-P

51

69

1900

1000V

CS10F-800-P CS10F-1000-P CS10F-1250-P

74

92

2420

1500V

CS15F-900-P CS15F-1250-P

105

123

3100

max.77

Current (A)

Operating time-current characteristic

CS10F-1500-C 7

Second

86 158

M10

M10

Time 5

M10

107 108

89.5 Second

Alarm contat block

99

74

Minute

7

40 72

08

ø15

72

Mass: 2500g

Current (A)

Max. Let-through current (Peak value) kA

Current-limiting characteristic

Available current (Sym, rms) I eff. (kA)

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice

08/35


Low Voltage Fuses BLC, CR and CS types Super Rapid Fuses

Characteristic curves CR2L, CR2LS Melting time-current characteristic

â–

Second

CR6L-350 CR6L-400 CR6L-500 CR6L-600

CR6L-200 CR6L-250 CR6L-300

CR6L-150

CR6L-100

CR6L-50 CR6L-75

CR6L-30

CR6L-20

Second

Time

Time

Minute

Minute

CR6L Melting time-current characteristic

Current (A)

Second

CR6L-20 CR6L-200 CR6L-20 CR6L-250 CR6L-20 CR6L-300 CR6L-350 CR6L-400 CR6L-500 CR6L-600

CR6L-150

CR6L-100

CR6L-50 CR6L-75

CR6L-30

Second

Time

Time

CR6L-20

Minute

Operating time-current characteristic

Minute

Operating time-current characteristic

Current (A)

Current (A)

Current (A)

Available current (Sym, rms) I eff. (kA)

08/36

Current-limiting characteristic

Max. Let-through current (Peak value) kA

Max. Let-through current (Peak value) kA

Current-limiting characteristic

Available current (Sym, rms) I eff. (kA)

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice


Low Voltage Fuses BLC, CR and CS types Super Rapid Fuses

Characteristic curves CS1F Melting time-current characteristic ■

Minute

Time Second

Second

Time

Minute

CS2F Melting time-current characteristic

Current ( × 103A)

Current ( × 103A)

Operating time-current characteristic

Time Second

Second

Time

Minute

Minute

Operating time-current characteristic

08

Current ( × 103A)

Current-limiting characteristic

Max. Let-through current (Peak value) kA

Max. Let-through current (Peak value) kA

Current-limiting characteristic

Current ( × 103A)

Available current (Sym, rms) I eff. (kA)

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice

Available current (Sym, rms) I eff. (kA)

08/37


Low Voltage Fuses BLC, CR and CS types Super Rapid Fuses

CS8F Melting time-current characteristic

Second

Second

Time

Time

Minute

Minute

■ Characteristic curves CS5F Melting time-current characteristic

Current ( × 10A) Current ( × 103A)

Operating time-current characteristic

Second

Second

Time

Time

Minute

Minute

Operating time-current characteristic

Current ( × 10A) Current ( × 103A)

Current-limiting characteristic

Max. Let-through current (Peak value) kA

Max. Let-through current (Peak value) kA

Current-limiting characteristic

Available current (Sym, rms) I eff. (kA)

Available current (Sym, rms) I eff. (kA)

08/38

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice


Low Voltage Fuses BLC, CR and CS types Super Rapid Fuses

Characteristic curves CS10F Melting time-current characteristic ■

Minute

Second

Second

Time

Time

Minute

CS15F Melting time-current characteristic

Current ( × 10A) Current ( × 103A)

Operating time-current characteristic

Second

Second

Time

Time

Minute

Minute

Operating time-current characteristic

08 Current ( × 10A) Current ( × 103A)

Available current (Sym, rms) I eff. (kA)

Current-limiting characteristic

Max. Let-through current (Peak value) kA

Max. Let-through current (Peak value) kA

Current-limiting characteristic

Available current (Sym, rms) I eff. (kA)

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice

08/39


Low Voltage Fuses BLC, CR and CS types Super Rapid Fuses

Operating indication Blown fuse indication FUJI Super Rapid Fuses are available in BLC, CR and CS types. These types have different methods of indicating a blown fuse. ● BLC type A blown fuse is indicated by the color tip on the ferrule of the fuse being ejected as shown in Fig. 1. This can be seen through the window of the fuse holder. ● CR type This fuse does not have a blown indicator but if a trigger fuse is connected as shown in Fig. 2 this will provide the alarm for blown fuse. ● CS type This fuse is provided with a blown fuse indicator. In this case a pin in the contact pad is ejected after the fuse has been blown. If electrical connections for lamps or alarms are required fit the contact block (1NO or 1NC) to the pad as shown in Fig. 3. ■

Fig. 3

Fig. 1

Alarm contact block AHX2905, 2915 SD-36

BLC type Fig. 2

CS10F

SM-385

Line Alarm circuit Trigger fuse

F

Alarm circuit

R

SH-384

CS 10F with alarm contact block

AF88-446

Load

CR type

Alarm contact block ratings

Type

Contact

AHX2905 1NO

AHX2915 1NC

Rated voltage (V)

AC Inductive cosϕ=0.3~1 Rated operational Rated current (A) capacity (VA)

24 110 220 440 550

■ Fuse holder for BLC type fuse FUJI BLC fuses require special holders. Select the most suitable one which corresponds to the rated current of the fuse. Dimensions: See page 08/28.

SD-36

Fuse link BLC

08/40

6 6 6 2.5 2

150 660 1320 1100 1100

Fuse link

Rated current

DC Resistive load Rated operational Rated current (A) capacity (W) 6 2.5 1 0.4 0.3

Type

(A)

Base Surface connection Type

BLC012-1 BLC020-1 BLC023-1 BLC045-1 BLC075-1 BLC090-1 BLC120-1 BLC140-1

12 20 23 45 75 90 120 140

AFa30 AFa30 AFa30 AFa60 AFa100 AFa100 AFa200 AFa200

Inductive load Rated operational Rated current (A) capacity (W)

150 275 220 175 165

6 1.3 0.45 0.2 0.15

150 140 100 85 85

Screw cap Rear connection Type

Adaptor ring

Type

Type

Ba30 Ba30 Ba30 Ba60 Ba100 Ba100 Ba200 Ba200

Pa30 Pa30 Pa30 Pa60 Pa100 Pa100 Pa200 Pa200

R20 – – – R75 – – –

AF88-439

Fuse holder Surface connection

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice


Low Voltage Fuses BLC, CR and CS types Super Rapid Fuses

Application and selection guide BLC, CR and CS-type – Super rapid fuse When selecting fuses for semiconductor rectifier circuit protection the following conditions must be satisfied. For additional details contact FUJI. ■

Conditions of application 1. The rated interrupting current of the fuse must be greater than the estimated short circuit current of the circuit. ■

Available short circuit current of rectifier circuit

<

Fig. (a)

Fuse ratings When selecting fuses various factors such as protection, coordination and load, etc. must be considered. However, in this catalog the main matters such as voltage, current and I 2t only are explained.

Line fuse method In this method the fuses are connected to the AC line side.

● Rated voltage The rated voltage of the fuse indicates the maximum operational voltage and this also indicates the root-meansquare value of the AC sinusoidal wave voltage. Select fuses having a rated voltage exceeding the voltage obtained by the formula shown in the following table. (Fig. 1) Do not select current-limiting fuses with rated voltages drastically exceeding the rectifier circuit voltage. It is necessary to consider the arc voltage.

Fig. (b)

Rated interrupting current of fuse

2. The let-thru current value of fuse must be less than the allowable 1/2 cycle surge current value. Fuse let-thru current value

< =

Semiconductor – 1/2 cycle allowable surge current 10ms (at 50Hz)

3. The total clearing I2t value which the fuse requires to complete interruption must be less than the allowable I2t value of semiconductor. Fuse – total clearing I2t

< =

Semiconductor – I2t

4. The rated current of the fuse must be greater than the average forward current of the semiconductor. Fuse – rated current

>

Element fuse method In this method the fuses are connected in series to the semiconductor element.

Fig. 1 Rated voltage required by fuses Wire connection type

Single-phase bridge

Wiring diagram

Rated voltage of Fuse (VFN rms) For line fuse For element fuse

Ea

VFN > = a · Ea

VFN > = a · Ea

VFN > = a · Ea

VFN > = a · 3 · Ea

VFN > = a · 3 · Ea

Semiconductor – average forward current

Ea

3-phase bridge

5. The rated current and voltage of the fuse must be greater than those of the rectifier circuit. Fuse – rated current and voltage

VFN > = a · Ea

Ea

>

Rectifier circuit – current and voltage

Method of application Semiconductor rectifier equipment has a variety of rectifier circuits. Taking the 3-phase bridge rectifier circuit as an example – Fig. (a) and (b) as shown in the following. Although the number of fuses used in the line fuse method (a) is half the number used in the element fuse method (b), the fuses must have a larger current capacity.

3-phase, double star

Remarks: The 'a' is a coefficient where the regulation of the AC input voltage is taken into account. This is a=1.1 in case of voltage regulation ±10%.

Fig. 2 Element current and line current Wire connection type

Wiring diagram

Element fuse method Element current Ia

Id

Single-phase bridge

I

Id

I

3-phase bridge

3-phase, double star

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice

Id Ia = __ √2 = 0.707d

Ia

Ia

Ia I

Id

Id Ia = __ √3 = 0.577dI

Line fuse method Line current I I =d

2 Id 3 = 0.816dI

I =

Id__ 2√ 3 = 0.289dI

I = Ia =

08/41

08


Low Voltage Fuses BLC, CR and CS types Super Rapid Fuses

Example I2t All I2t values are ampere2 seconds. 08/42

Peak let-thru current (Actual short-circuit current)

Calculation

Peak current of first half cycle of available peak current (AC component) Short circuit current that would pass without currentlimiting fuse. DC component

From the table (Page 08/38), the fuse with a total I2t nearest to 30,400A2 Sec. is the 260 Ampere fuse (CR 2L-260).

Current

Maximum I2t diode = ( 1 Peak )2 0.0167 2 = ( 2700 )2 0.0167 2 = 30,400A2 Sec.

Interrupting current The rated interrupting current of the fuse must exceed the maximum value (Symmetrical RMS value) of the estimated circuit fault current. ■

T

How to find a let-thru current – Example Fuse: 200 Amps 500V Available R.M.S symmetrical current: 100,000 Amps

pe ak

Available

11,600

Let-thru

200A

in

Current limitation Select a fuse whose let-thru current value does not exceed the allowable 1/2 cycle surge current of the semiconductor. The allowable surge current is the peak value of the current which in case at 50Hz is allowed to flow for 10ms. In the current-limiting fuse the fault must be cleared in the shortest possible time or in the first 1/2 cycle. Available current is the current which would flow if the fuse were not currentlimiting. This would cause damage to equipment. Let-thru current is the actual current allowed to flow by the current limiting action of the fuse. A number of let-thru current graphs are given in this catalog and example is given in the following paragraph. The method of reading this graph is provided for your reference. ■

105,000

cu rre nt Pf =1

M:Melting time A :Arcing time T :Total clearing time

st an ta ne ou s

Peak arc voltage In the case of the current-limiting fuse an arc voltage (overvoltage) is generated at the time of interruption due to its fusible element construction. It is necessary to check that this peak arc voltage does not exceed the semiconductor's maximum (Nonrepetitive peak) reverse voltage value.

Time M A

la bl e

Total clearing I t The total clearing I 2 t of fuse is a very important factor when considering the protective coordination of the semiconductor. This total clearing I 2t is the value where the arcing I 2 t is added to the melting I 2t. Therefore it is necessary to satisfy the following formula. Fuse – total < Semiconductor clearing I2t = I2t The total clearing I 2 t of fuse depends upon the operational voltage and interrupting current. Therefore, for this reason if a 500 Volts fuse is used in a 300 Volts circuit the total clearing I2t is reduced by 50–70%. However, the reduction rate varies according to the type of fuse construction. This must be checked and confirmed once more. ■

Let-thru peak current (Instantaneous): 11,600 Amps Let-thru R.M.S. current 11,600 ÷ 1.7 = 6,800 Amps This example clearly shows that while a 100kA (rms, sym) current is available, the fuse limits the current letthru to 6,800 Amperes (rms, sym).

Av ai

2

The I2t data for silicon diodes or thyristor elements are normally given in their respective catalogs. If the A 2S data is not given in their catalog obtain the value in the following manner. If protection is needed for a 250V, 150A (Io) diode having a maximum allowable peak half sine wave current of 2700A, it is important that the fuse has a total I 2 t value lower than that of the diode.

Let-thru peak current(Amperes)-Peak

Rated current The current values in fuses in the line fuse system and the element fuse system are different. Obtain the correct current value from the table on page 08/41 (Fig. 2). When selecting the rated current of a fuse choose a fuse having an amperage rating greater than the current which flows in the semiconductor if the load is continuous and a fixed current. If the current which flows in the semiconductor is greater than the rated current of the fuse connect the fuses in parallel. However, in this case, if the numbers of fuses arranged in parallel are 'n', then the I2t value of the fuse will be n2·I2t and n2 times the I2t value of one fuse. This should be taken into consideration when protective coordination is taken into account. In the case of the circuit where the load rapidly varies the fuse element will suffer from mechanical deterioration and be damaged by thermal stress. In loads of this type the deterioration characteristics of the fuse must be closely considered. Moreover if the fuse current – time characteristics of the fuse selected is less than the overload characteristics of the semiconductor element then complete protection can be obtained. However, if the semiconductor element has a large capacity then protective cooperation is very difficult to arrange. The fuses are used to isolate the shorted semiconductor element circuit from sound operating circuits. ●

100,000A Available RMS symmetrical current(Ampere)

Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice


Catalog Disclaimer The information contained in this catalog does not constitute an express or implied warranty of quality, any warranty of merchantability of fitness for a particular purpose is hereby disclaimed. Since the user's product information, specific use application, and conditions of use are all outside of Fuji Electric FA Components & Systems'control, it shall be the responsibility of the user to determine the suitability of any of the products mentioned for the user's application. One Year Limited Warranty The products identified in this catalog shall be sold pursuant to the terms and conditions identified in the "Conditions of Sale" issued by Fuji Electric FA with each order confirmation. Except to the extent otherwise provided for in the Conditions of Sale issued by Fuji Electric FA, Fuji Electric FA warrants that the Fuji Electric FA products identified in this catalog shall be free from significant defects in materials and workmanship provided the product has not been: 1) repaired or altered by others than Fuji Electric FA; 2) subjected to negligence, accident, misuse, or damage by circumstances beyond Fuji Electric FA's control; 3) improperly operated, maintained or stored; or 4) used in other than normal use or service. This warranty shall apply only to defects appearing within one (1) year from the date of shipment by Fuji Electric FA, and in such case, only if such defects are reported to Fuji Electric FA within thirty (30) days of discovery by purchaser. Such notice should be submitted in writing to Fuji Electric FA at 5-7, Nihonbashi Odemma-cho, Chuo-ku, Tokyo, Japan. The sole and exclusive remedy with respected to the above warranty whether such claim is based on warranty, contract, negligence, strict liability or any other theory, is limited to the repair or replacement of such product or, at Fuji Electric FA's option reimbursement by Fuji Electric FA of the purchase price paid to Fuji Electric FA for the particular product. Fuji Electric FA does not make any other representations or warranties, whether oral or in writing, expressed or implied, including but not limited to any warranty regarding merchantability or fitness for a particular purpose. Except as provided in the Conditions of Sale, no agent or representative of Fuji Electric FA is authorized to modify the terms of this warranty in writing or orally. In no event shall Fuji Electric FA be liable for special, indirect or consequential damages, including but not limited to, loss of use of the product, other equipment, plant and power system which is installed with the product, loss of profits or revenues, cost of capital, or claims against the purchaser or user of the product by its customers resulting from the use of information, recommendations and descriptions contained herein. The purchaser agrees to pass on to its customers and users, in writing at the time inquiries and orders are received by buyer, Fuji Electric FA's warranty as set forth above. Caution "Safety precautions" • Operate (keep) in the environment specified in the operating instructions and manual. High temperature, high humidity, condensation, dust, corrosive gases, oil, organic solvents, excessive vibration or shock might cause electric shock, fire, erratic operation or failure. • Follow the regulations of industrial wastes when the product is to be discarded. • The products covered in this catalogs have not been designed or manufactured for use in equipment or systems which, in the event of failure, can lead to loss of human life. • If you intend to use the products covered in this catalog for special applications, such as for nuclear energy control, aerospace, medical, or transportation, please consult our Fuji Electric FA agent. • Be sure to provide protective measures when using the product covered in these catalogs in equipment which, in the event of failure, may lead to loss of human life or other grave results. • Follow the directions of the operating instructions when mounting the product.


08

Individual catalog No.

LOW VOLTAGE PRODUCTS Up to 600 Volts

01

Magnetic Contactors and Starters Thermal Overload Relays, Solid-state Contactors

02

Manual Motor Starters and Contactors Combination Starters

03

Industrial Relays, Industrial Control Relays Annunciator Relay Unit, Time Delay Relays

04

Pushbuttons, Selector Switches, Pilot Lights Rotary Switches, Cam Type Selector Switches Panel Switches, Terminal Blocks, Testing Terminals

05

Limit Switches, Proximity Switches Photoelectric Switches

06

Molded Case Circuit Breakers Air Circuit Breakers

07

Earth Leakage Circuit Breakers Earth Leakage Protective Relays

08

Circuit Protectors Low Voltage Current-Limiting Fuses

09

Measuring Instruments, Arresters, Transducers Power Factor Controllers Power Monitoring Equipment (F-MPC)

10

AC Power Regulators Noise Suppression Filters Control Power Transformers

INDIVIDUAL CATALOG from D&C CATALOG 20th Edition

D&C CATALOG DIGEST INDEX

CP-F type Circuit protectors

CP-P type Circuit protectors

CP-B type Circuit protectors

CIRCUIT PROTECTORS CP-V type Circuit protectors

LOW VOLTAGE CURRENT - LIMITING FUSES

HIGH VOLTAGE PRODUCTS Up to 36kV

11

Disconnecting Switches, Power Fuses Air Load Break Switches Instrument Transformers — VT, CT

12

Vacuum Circuit Breakers, Vacuum Magnetic Contactors Protective Relays

AFaC and BaC types HRC fuses

LOW VOLTAGE EQUIPMENT Up to 600 Volts

INDIVIDUAL CATALOG from D&C CATALOG 20th Edition

08

BLC, CR and CS types Super Rapid Fuses

INDIVIDUAL CATALOG from D&C CATALOG 20th Edition 01 02 03 04 05 06 07

5-7, Nihonbashi Odemma-cho, Chuo-ku, Tokyo, 103-0011, Japan URL http://www.fujielectric.co.jp/fcs/eng

Information in this catalog is subject to change without notice. 2010-04 PDF FOLS DEC2008

08

09 10 11 12

08


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.