UNT 1

Page 1

The University of North Texas 1601 Bryan Street, Suite 101 Dallas, Texas 75201 p. 214.922.9000 f. 214.871.3307


1.0

2

Symbols, Abbreviations, and Definitions Program Contributor Acknowledgements Program Benchmarks Program Contributor Acknowledgements

000

Program Contributor Approvals

2.0 2.1

Executive Summary Project Overview

3.0 3.1 3.2 3.3 3.4 3.5 3.6

Project Goals Mission and Objectives 3.1.1 Universal Campus Plan Objectives 3.1.2 CVAD Project Mission 3.1.3 CVAD Objectives Strategic Plan Master Plan Functional Programs, curricula, Descriptions and Projections 3.4. 1 Projections Project Need 3.5.1 Overall Project Scope 3.5.2 Project Intent 3.5.3 Alternative Solutions Compliance with the Space Model

4.0 4.1 4.2 4.3 4.4 4.5 4.6 4.7

Space and Adjacency Requirements Space Program Summary 4.0.1 Programming Process 4.0.2 Space Types Summary 4.0.3 Planning Module Narrative 4.0.4 Planning Module Diagram 4.0.5 External Department Adjacency - Option 1 Summary 4.0.6 External Department Adjacency - Option 1 Diagram 4.0.7 External Department Adjacency - Option 2 Summary 4.0.8 External Department Adjacency - Option 2 Diagram 4.0.9 Alternative Program Scenarios - Proposed Reductions 4.0.10 Space Analysis Diagrams Introduction to Departments and Programs Program Room List Square Footage Concise Summary General Spaces and Building / College Dean Advising Suite Shared Spaces Department: AEAH Department: Design Department: Studio Arts

5.0 Supplemental Requirements 5.1 Environment, Health and Safety Requirements 5.2 Site Development Requirements 5.3 Special Design Requirements 5.3.1 Accessibility 5.3.2 Flexibility and Adaptability 5.3.3 Sustainability 5.3.4 HVAC 5.3.5 Vibration / Structural Considerations 5.3.6 Noise Control 5.3.7 Purified Water Systems 5.4 Security 6.0 Existing Site Studies 6.1 Campus Planning Issues 6.1.1 Block Pattern 6.1.2 Utilities 6.1.3 Site Dimensions 6.1.4 Planning Recommendations 6.2 CVAD Building Site Plan Issues 6.2.1 Site Design Options 6.2.2 Optimal Site Capacity 6.2.3 CVAD Planning Synopsis 7.0 Existing Facilities Studies 7.1 Overview and Recommendations 7.1.1 Summary of Existing Conditions 7.1.2 Viability for Modernization of the Art Building 7.1.3 Conclusion and Recommendations 7.2 Existing Data and Evaluation Studies 7.3 Code Compliance 7.3.1 Texas Accessibility Standards (TAS) 7.3.2 Fire and Life Safety 7.3.3 Energy Efficiency 7.3.4 Other Construction Compliance 8.0 8.1 8.2

Design Parameters Applicable Codes and Standards Technical and Design Standards 8.2.1 Civil 8.2.2 Architectural 8.2.3 Mechanical 8.2.4 Electrical Systems 8.2.5 Plumbing and Fire Protection 8.2.6 Structural 8.2.7 Information Technology 8.2.8 Audio / Visual Systems 8.2.9 Landscaping

-

UNT CVAD Program Report


9.0

Preliminary Project Cost

10.0 Project Schedule 10.1 Project Milestone Schedule 11.0

Implementation Approach

12.0

Information Specific to UNT - Denton

13.0

Selecting a Project Delivery Method

14.0 Appendix

TABLE OF CONTENTS

-

UNT CVAD Program Report

3


SYMBOLS Symbols, Abbreviations, and Definitions This section identifies the symbols and abbreviations used in this chapter and it provides definitions of frequently used terms. Symbols The following symbols are used to illustrate key concepts in this chapter: Abbreviations Many Terms used in this chapter have been abbreviated ACC Austin Community College District ADA Americans with Disabilities Act AFF Above Finished Floor ASF Assignable Square Feet CCTV Closed Circuit Television CMU Concrete Masonry Unit CSAT Computer Science and Advanced Technology Dim. Dimmable DS Disability Services FA Financial Assistance FRP Fiberglass Reinforced Plastic FTE Full Time Enrollment GFCI Ground Fault Circuit Interrupter GSF Gross Square Feet GWB Gypsum Wall Board HVAC Heating, Ventilation and Air Conditioning IDF Intermediate Data Frame IRT Instructional Learning and Technology EW/SS Eyewash/Safety Shower LSF Linear Square Feet MC Media Center MDF Main Data Frame MEP Mechanical, Electrical, and Plumbing N/A Not Applicable PC Personal Computer SF Square Feet VA Veteran’s Affairs VCT Vinyl Composition Tile

4

-

UNT CVAD Program Report


ABBREVIATIONS

ADA - Americans with Disabilities Act AEAH - Art Education Art History AFF - Above Finished Floor ASF - Assignable Square Feet CVAD - College of Visual Arts and Design CAMSCI - Contemporary Arab + Muslim Cultural Studies Institute FTSE - Full Time Student Enrollment GFCI - Ground Fault Circuit Interrupter GSF - Gross Square Feet GWB - Gypsum Wall Board HVAC - Heating, Ventilation and Air Conditioning EW/SS - Eyewash / Safety Shower LSF - Linear Square Feet MC - Media Center MEP - Mechanical, Electrical, and Plumbing N / A - Not Applicable NTIEVA - North Texas Institute for Educators on the Visual Arts PC - Personal Computer R.D.S. - Room Detail Sheet SF - Square Feet TFC - Texas Fashion Collection

-

UNT CVAD Program Report

5


COLOR LEGEND FOR SPACE STYPE

6

-

UNT CVAD Program Report


COLOR LEGEND FOR PROGRAMS

-

UNT CVAD Program Report

7



01 PROGRAM CONTRIBUTOR ACKNOWLEDGEMENTS


1.0 PROGRAM CONTRIBUTOR ACKNOWLEDGEMENTS PROGRAM CONTRIBUTOR ACKNOWLEDGEMENTS Fostering global understanding and promoting cultural appreciation are central to preparing tomorrow’s successful global leaders. Our strategic international partnerships seek to improve quality of life, facilitate the exchange of ideas and culture, and allow for important research addressing global issues. UNT hosts visiting scholars and faculty from more than 50 countries and offers global learning and experience programs in more than 37 nations. UNT’s campus also benefits from a rich diversity of international students.

10

-

UNT CVAD Program Report


1.0 PROGRAM BENCHMARKS

PROGRAM BENCHMARKS As a public university, we bear a special responsibility to advance and improve society. Our faculty, staff and students take seriously this obligation to do more to make a difference.

-

UNT CVAD Program Report

11


1.0 PROGRAM CONTRIBUTOR APPROVALS SIGNATURES

programming approval from

I have reviewed the programming packet prepared by lauckgroup dated 07-19-2013. My signature below indicates approval of the following for my department and each program within my department:  external program adjacencies (overall, option 1 and option 2)  space program list summary  adjacency diagram (internal to program)  graphic space program  room detail sheets  room plans The following documents were included for reference and information. Edits to information in these documents is noted on the space program list summary Excel file.  

Melissa Cooksey date

07-19-2013 project

UNT CVAD code

1358-01.05

concise space program summary graphic space program

regarding

____________________________________________________

________

Signature of Department Representative

Date

Programming – Departmental Approval

_________________________________________________________ Department

1601 bryan street suite 101 dallas texas 75201 214.922.9000 main 214.871.3307 fax

12

-

UNT CVAD Program Report


-

UNT CVAD Program Report

13



02 EXECUTIVE SUMMARY


2.0 EXECUTIVE SUMMARY PROJECT OVERVIEW

The following Project Program and Site Studies Report defines the project scope for the CVAD Programming Project. The project combines two discrete projects into a single multi-phased project that will provide new and renovated facilities for the University of North Texas, College of Visual Arts. The project includes the renovation of the existing 96,000 gross square foot Art Building and construction of a new enlarged College of Visual Arts Building (CVAD) to be located at the northeast corner of Welch Street and West Mulberry Street on the University’s main campus in Denton, Texas. The new facility for the CVAD will comprise 180,000 gross square feet (GSF) which includes the assignable program areas required for the Visual Arts Programs. It is anticipated, based upon preliminary programming investigations, that first phase of the existing Art Building renovations will include approximately 96,000 GSF. This portion of the project scope will require relocation of existing research and teaching laboratory spaces from various areas of the Art Building to the new space in the completed CVAD Building. The CVAD Project will be completed in five phases as follows: • CVAD Project Phase 1 – abatement of hazardous materials in the existing Art Building. • CVAD Project Phase 2 – demolition of various areas of the existing Art Building. • CVAD Project Phase 3 – new construction of the 180,000 GSF CVAD Building. • CVAD Project Phase 4 – relocate programs from Oak Street Hall to the new CVAD Building. • CVAD Project Phase 5 – renovation of portions of the existing Art Building. The purpose of the CVAD Program and Site Studies phase is to establish the goals, parameters and constraints of the project in sufficient detail to provide conceptual guidance for the subsequent design phases of the project and to confirm the estimated Preliminary Project Cost (PPC). It is also the intent of this phase to establish specific space requirements, determine internal and external functional relationships, define site design goals and develop studio and building technical design criteria. The proposed space program for the CVAD is comprised of 180,000 assignable square feet (ASF) in several major program elements including: Public Space, Meeting and Conference Space, Instructional Space, Administrative Office Space, and Studio/Lab, Support and Office Space. The CVAD programming process included an evaluation of all building program requirements, including benchmark building comparisons and an evaluation of specific project requirements that may affect the building organization or anticipated efficiency ratios. The new CVAD facility as a whole will provide space for an integrated and interdisciplinary approach to education, research and development for College of Visual Arts programs including the Department of Art Education and Art History, Department of Design, and the Department of Studio Art. In addition the program includes space for outdoor shop facilities; administrative offices serving the Dean and Advising department; public areas such as a main lobby, break rooms and informal interaction spaces; conference and meeting rooms as well as instructional spaces such as a seminar room and multi-media and student oriented computer labs. Additional new areas include University Gallery Space and upgrade IT Technology. The new CVAD facility will be constructed on the site of the existing reserved/faculty and staff parking lot in order to replace and enlarge the antiquated facilities and to provide the appropriate intensive studio based infrastructure necessary for the college to compete with other nationally recognized visual arts programs. The program for the existing Art Building, while still in need of further program development is anticipated to include some administrative functions for the CVAD as well as studio/labs and instructional spaces.

16

-

UNT CVAD Program Report




03 PROJECT Departments GOALS


3.0 PROJECT GOALS MISSION AND OBJECTIVES

UNIVERSITY CAMPUS PLANNING OBJECTIVES The mission of The University of North Texas is to achieve excellence in the interrelated areas of undergraduate education, graduate education, research, and public service. The University provides superior and comprehensive educational opportunities at the baccalaureate through doctoral and special professional educational levels. The University contributes to the advancement of society through research, creative activity, scholarly inquiry, and the development of new knowledge. The University preserves and promotes the arts, benefits the state’s economy, serves the citizens through public programs, and provides other public service. ART BUILDING PROJECT MISSION The existing Art Building at the University of North Texas represents the College of Visual Arts programs in the Department of Art Education and Art History, Department of Design, and the Department of Studio Art. The College is seeking to expand the number of Faculty and students through active recruitment for specific research programs; however, the success of this effort is currently limited by the amount and quality of studio/lab space available to accommodate new hires and new specialized facilities. Specific programs considered during the CVAD planning process include: Department of Art Education and Art History programs: • Art Education (AE) • Art History (AH) • North Texas Institute for Educators on the Visual Arts (NTIEVA) • Contemporary Arab and Muslim Culture and Studies Institute (CAMCSI)

Department of Design programs: • Communication Design (CD) • Fashion Design (FD) • Interior Design (ID) • Texas Fashion Collection (TFC)

Department of Studio Art programs: • Ceramics • Drawing and Painting • Fibers • Metalsmithing and Jewelry • New Media Art • Photography • Printmaking • Sculpture

COLLEGE OF VISUAL ARTS PROJECT MISSION The College of Visual Arts has established broad and narrow focus objectives for the planning process associated with the CVAD project. They range from campus scale issues dealing with physical adjacencies of facilities within a campus district to issues of safety, security and deficiencies in existing infrastructure. The program and site planning studies have attempted to address the following issues to varying degrees many of which will ultimately be resolved with the completion of the CVAD project. • District site planning for the College of Visual Arts • Maximum site carrying capacity and optimum utilization of CVAD site • Consolidation and co-location of related art programs • Administrative unity of Sections within the programs • Space and functional program needs to fulfill growth projections for specified CVAD disciplines • Space and functional program needs to fulfill relocation needs and growth projections • Appropriate re-use of the existing Art Building facilities • Safety and infrastructure deficiencies in the existing Art Building facilities • Consolidation of loading dock needs for the existing Art Building and the New CVAD Building • Securable Gallery zones separated for public access zones

20

-

20

UNT CVAD Program Report


Ana M Lopez


3.0 PROJECT GOALS UNT STATISTICS

Studio Art Graduate Total

SEMESTER CREDIT HOURS

Studio Art Undergraduate Total Design Graduate Total Design Undergraduate Total

2011-2012

AEAH Graduate Total

2009 -2010

2010-2011

AEAH Undergraduate Total 0

2000

4000

6000

8000

10000

12000

Undergraduate Enrollment Projection

UndergraduateEnrollment Projections 12,000 10,000 8,000 6,000 4,000

9,260

6,689 5,856 5,437

9737

7,068

10,089

7,497

9928

Historical

9842

10,178

10,145

10,145

10,269

10,362

10,367

10,456

10,536

10,586

Projected

7,569

7,577

7,594

7,772

7,843

7,894

8,101

8,167

7,325

8,000

7,183

5,861

5,864

5,973

5,878

5,933

5,949

5,959

5,951

5,986

5,988

5,998

6,011

6,026

5,111

5,024

5,199

5,237

5,108

5,198

5,230

5,201

5,210

5,252

5,245

5,252

5,272

2008

2009

2010

2011

2012

2013

2014

2015

2016

2017

2018

2019

2020

2,000 0

2007

Freshman

Housing Projections

Sophomore

Junior

Senior

17

source: http://institutionalresearch.unt.edu/sites/default/files/Fact_Book-2012-2013.pdf Source: http://untsystem.edu/untmasterplan/documents/WEB-130206_UNT_MP_WKSHP_5.pdf

22

-

UNT CVAD Program Report


3.0 PROJECT GOALS CLASS / LAB / STUDIO ROOM PLAN

TOTAL ENROLLMENT

UG ENROLLMENT

UG BEDS

OTHER BEDS

TOTAL BEDS

±34,560

28,283 (81%)

5,487 (19%)

367

5,854

+125

+778

492

6,642

+172

+1,402

750

8,044

+213

+1,608

850

9,653

+511 beds

+3,800

2011

+ 663

2015

37,500

30,000 (80%)

6,150 (20%) +1,230

2020

41,000

7,380 (22%)

32,800 (80%)

+1,395

2025

45,000

8,775 (25%)

35,100 (78%)

+3,288

• Other Beds = TAMS & Graduate and Family • Scheduled renovation/replacement ? HOUSING

-

UNT CVAD Program Report

23



04 SPACE AND ADJACENCY REQUIREMENTS


4.0 Space and Adjacency Requirements 4.0 4.1 4.2 4.3 4.4 4.5 4.6 4.7

26

Space and Adjacency Requirements Space Program Summary 4.0.1 Programming Process 4.0.2 Space Types Summary 4.0.3 Planning Module Narrative 4.0.4 Planning Module Diagram 4.0.5 External Department Adjacency - Option 1 Summary 4.0.6 External Department Adjacency - Option 1 Diagram 4.0.7 External Department Adjacency - Option 2 Summary 4.0.8 External Department Adjacency - Option 2 Diagram 4.0.9 Alternative Program Scenarios - Proposed Reductions 4.0.10 Space Analysis Diagrams Introduction to Departments and Programs Program Room List Square Footage Concise Summary General Spaces and Building / College Dean Advising Suite Shared Spaces Department: AEAH Department: Design Department: Studio Arts

-

UNT CVAD Program Report


Harlan Butt -

UNT CVAD Program Report

27


4.1.0 PROGRAM AREA

place holder, B.P.

28

-

UNT CVAD Program Report


4.1.0 PROGRAM AREA

-

UNT CVAD Program Report

29


4.0 SPACE AND ADJACENCY REQUIREMENTS PROGRAMMING PROCESS

Existing Art Building The existing 96,000 GSF Art Building has been deemed an unacceptable candidate for modernization due the existing available technology. Because the building was not specifically designed for the unique characteristics required by many of the CVAD programs, many of the spaces would require significant remodeling in order to adequately house them. The existing lab and studio spaces are not particularly well suited to housing current types of spaces, due to the lack of expansion space, infrastructure, layout and design. The existing Art Building does not have sufficient studio, lab or shop space to house the entire CVAD program. Further, there are few opportunities for incorporating new spaces to properly compete with other nationally recognized art programs. For these reasons it is recommended that the existing Art Building house the Department of Art Education and Art History as well as the Department of Design which includes the following programs: AEAH/NTIEVA/CAMCSI AEAH Chair Suite Fashion Design Texas Fashion Design Interior Design Design Chair Suite Communication Design Existing Gallery Spaces New CVAD Building Ideally, the College wants to physically bring the CVAD programs together to promote open collaboration between the disciplines as well as create adequate facilities and support spaces. The New CVAD building will be highly suitable for housing the Department of Studio Arts which mainly comprises of art studio and lab spaces that depend heavily on specialized spaces with very specific infrastructure needs such as technology, lighting and oversized spaces. The design of the building will embody a new kind of synergy throughout the College. The proposed new College of Visual Arts Building (CVAD) provides approximately 180,000 GSF of space for the following programs: Metalsmithing and Jewelry Ceramics Industrial Design Sculpture New Media Photography Drawing and Painting Printmaking Print Press New Gallery Spaces Fibers Artist Apartment IT Studio Arts Chair Suite Dean/Advising Suite

30

-

UNT CVAD Program Report


4.0 SPACE AND ADJACENCY REQUIREMENTS PROGRAMMING PROCESS The Programming Team conducted several programming interviews to establish future space requirements and functional needs for the UNT College of Visual Arts and Design (CVAD.) The interviews consisted of meetings with the Dean and Associate Dean of the College of Visual Arts and Design as well as representative Faculty members to discuss space allocations and program requirements to be included in the existing and new building. Detailed and specific requirements for the respective departments were gathered, utilizing the room detail sheets, framework questions, supplemental interview notes and field verifications. The final Summary Space List represents the strategic decisions made together with the College’s and University’s administrative leadership to best utilize both new and existing space. The existing CVAD programs included areas used in the following buildings: Art Building, Bain Hall, Curry Hall, portions of Hickory Hall containing Studio Art’s Metalsmithing space, Oak Street, Oak Street Annex and Scoular Hall. Per the Universities request, the following CVAD programs were not included in this study: Core Drawing and Design and Ruth West. All of these areas were considered to fulfill the long term goals for program expansion, faculty recruitment, appropriate location and adjacencies of program areas. Internal and external department and program adjacencies informed the decision as to which programs will be located in the new CVAD building and which will be located in the existing Art Building. The final space program includes the following for inclusion in the CVAD Project: Office(s) of the Dean and Advising (IT) Technology Team UNT Art Galleries Artist Apartment Department of Art Education and Art History:  Chairperson Suite  Art Education  Art History  NTIEVA  CAMCSI Department of Design:  Chairperson Suite  Communication Design  Fashion Design  Interior Design  Texas Fashion Collection (TFC) Department of Studio Art:  Chairperson Suite  Ceramics  Drawing and Painting  Fibers  Metalsmithing and Jewelry  New Media Art  Photography  Printmaking  Sculpture -

UNT CVAD Program Report

31


32

-

UNT CVAD Program Report

"Red Hot Tamale" by Li-Fen Anny Chang, 2002


2.0 SPACE PROGRAM SUMMARY SPACE TYPE SUMMARY

General Purpose Classrooms The shared Classroom spaces refer to standardized seminar spaces for a course of intense study relating to the student's major. Classrooms typically have 20-25 students per professor and generally do not contain any equipment in these areas. Classrooms can revolve around term papers, exams, presentations, and several other assignments. The Classroom types and are designated by the university guidelines. Various other resource spaces are provided within the program to support the Instructional goals of the school. The Lecture/Seminar Rooms provide a formal multi-purpose space for 120 people where the College can host formal symposiums, lectures and meetings for large groups. This space should be outfitted with technology and audio/visual systems for training and instructional purposes and should be adaptable to advances in future technology. A lounge / workroom and study areas for students will be provided to create a central gathering space for students who are not actively working in the labs or attending classes. These spaces will provide a hub for the students to congregate. A more detailed description of each programs critique room requirements is located in the following Room Detail Sheets, Room Layouts, and the Space Program List. Non Assignable Spaces This category includes all spaces included in the 45% net-to-gross factor. Circulation spaces, stairs, elevators, restrooms, custodial spaces, mechanical, electrical and low voltage rooms, shafts, vents and penetrations are included in this category. Critique Spaces The shared Critique spaces refer to standardized presentation spaces for various disciplines to use at a variety of times. Critique spaces are assigned to specific departments but should be located and sized to allow for flexible assignment in the future. These rooms are typically used for review or commentary, and allow a critical discussion of a specified work of art. Critique spaces typically have 20-25 chairs and generally do not contain any equipment, must have adequate lighting as specified per program, and are generally clean areas to allow complete focus on the works of art up for discussion. A more detailed description of each programs critique room requirements is located in the following Room Detail Sheets, Room Layouts, and the Space Program List. Circulation The Circulation is the interior space required for internal building circulation not accounted for in the Assignable Square Footage for each program space. We use a Circulation Factor of 45% or .8181 x the Assignable Square Footage to calculate the circulation square footage. Additional information may be found in the Space Program List. Building Support Spaces Spaces listed as Building Services include support functions that do not belong with a specific department but support the entire school. These spaces should be conveniently located throughout the building.

-

UNT CVAD Program Report

33


4.0 SPACE AND ADJACENCY REQUIREMENTS 4.1 SPACE PROGRAM SUMMARY 4.1.2 SPACE TYPE SUMMARY

Gallery The Gallery spaces are used to display works of art. The exhibit is universally understood to be for some temporary period. Such expositions may present pictures, drawings, video, sound, installation, performance, interactive art, new media art or sculptures by individual artists, groups of artists or collections of a specific form of art. Sometimes the events are open to the public and on weekends. Natural light is undesirable because of its intensity and high UV content. Security is important to reduce the risk of loss from theft or vandalism. A more detailed description of each programs critique room requirements is located in the following Room Detail Sheets, Room Layouts, and the Space Program List. Studio Lab The Studio/Lab spaces refer to spaces where art is made, taught and studied and generally contain specific equipment used for that particular discipline. Each department utilizes these areas as student workrooms as well as lecture rooms. A more detailed description of each laboratory and studio support space can be found in the Room Detail Sheets, Room Layouts, and the Space Program List. Public Spaces Public Spaces support interaction and collegial activities and can be a catalyst for the collaborative environment. There are a variety of public spaces with varying scales, adjacencies, and levels of formality and privacy in the program. A Lobby atrium will serve as a pre-function area for adjacent meeting rooms, galleries and instructional space on the first and second levels. The atrium will also provide a central hub for the surrounding studio and teaching activities. Communicating stairs will provide open and convenient access between the levels. There are several informal interaction spaces in strategic locations adjacent to primary circulation patterns, and adjacent to studio/labs, which provide impromptu gathering spaces to promote interaction and informal meetings among faculty and students. Break rooms will offer seating areas and simple food preparation space in order to discourage the use of the labs/studios for dining or social breaks. Copy /Support rooms will be distributed but adjacent to faculty offices and studios. Outdoor Shop The Outdoor Shop spaces are an extension of the studio spaces for disciplines requiring outdoor work areas such as Sculpture and Ceramics. Refer to the Room Detail Sheets, Room Layouts, and the Space Program List for additional information. Support Spaces The Support spaces refer to spaces used for functions that support the studios and labs. These spaces range from storage rooms to chemical rooms to dark rooms. There vary greatly in size, equipment and infrastructure requirements. A more detailed description of each laboratory and studio support space can be found in the Room Detail Sheets, Room Layouts, and the Space Program List.

34

-

UNT CVAD Program Report


4.0 SPACE AND ADJACENCY REQUIREMENTS 4.1 SPACE PROGRAM SUMMARY 4.1.2 SPACE TYPE SUMMARY

Meeting and Conference Space Various types of meeting spaces are provided within the program to support collaboration in the CVAD Building. A large conference room with a 40 person capacity will have reconfigurable tables and chairs, with multimedia and audiovisual capabilities. One medium sized conference room for 20 people and two smaller 10 person meeting rooms will be located on each floor of the respective buildings. They should be located adjacent to the faculty offices and will provide space for informal gatherings of students and faculty. Graduate Space Graduate Students are provided with an individual studio. The student offices should be accessed from the main corridors to allow easy access for both students and faculty. Graduate studios should be dispersed throughout the building and should be reassignable between departments to accommodate varying graduate student numbers. It may be necessary to combine several graduate studios into one larger group studio for some disciplines. A flexible wall system may be required to meet this functional requirement. Additional information can be found in the Room Detail Sheets, Room Layouts, and the Space Program List. General Purpose Faculty Offices The Faculty Offices are assigned according to staff level and determined by the university guidelines. Faculty Offices will house Professors, Adjunct Professors, Teaching Assistants and Tech’s. Faculty offices are programmed at 120 ASF each and should be located in relative proximity to the discipline that they serve; however they should also be easily accessible to students. Faculty Offices should be grouped together where possible to promote interaction and collaboration amongst professors. The Room Detail Sheets indicate the preferred office adjacencies per discipline.

-

UNT CVAD Program Report

35


4.0 SPACE AND ADJACENCY REQUIREMENTS 4.1 SPACE PROGRAM SUMMARY 4.1.3 PLANNING MODULE NARRATIVE

The concept of the module diagram is based on the idea that like functions can be grouped into zones. Over time, the spaces in each zone can expand, contract and relocate with minimal architectural change The program spaces can be grouped by function into 5 broad categories. 1. Studio and lab spaces: these spaces are large and usually have very special requirements such as high ceiling height, direct access to outdoor functions, plumbing, exhaust and other specific technical requirements. These are the spaces that students do work in. The majority of these spaces are large (sizes range from 300 s.f. to 2500 s.f.) and are therefore located in a 30’ deep zone along the perimeter zone of the building. If necessary, these spaces can overflow into the 20’ deep support zone. Services in this zone, such as water, air and exhaust can be located at regular intervals to facilitate future changes. Examples of studios and labs are: Letterpress Studio, Screen/Intaglio Studio, Lighting Studio, Lithography Studio, Etching Relief Studio and the Advanced Major Lab, Hand Building Lab, and the Lighting Lab. 2. Support spaces: These spaces are highly technical and specific to each department but are smaller in scale that the studio and lab spaces(sizes range from 150 s.f. to 5000 s.f.). These spaces support the studios and labs. The spaces may require the same services as the studios and labs and need the same degree of flexibility for future changes. The 20’ deep zone allocated for these functions will be subdivided into smaller spaces with adequate circulation Examples of support spaces are: Collection Room, Darkrooms, Chemical Rooms, Clay Mixing Room, Electric Kiln Room, Storage Rooms and Resource Rooms. 3. Outdoor spaces: Some of the departments require outdoor space to make work and there is an immediate adjacency requirement between the lab/studio and the outdoor space. Examples of outdoor spaces are: Ceramics Kiln Yard and Fabrication Storage Area, Sculpture Courtyard Shop/Foundry/Welding, as well as the Industrial Design and Metalsmithing and Jewelry Outdoor Shops. 4. Classrooms, offices and critique rooms: These spaces typically do not require special services and can have more typical ceiling heights (except critique rooms). These spaces also tend to be interchangeable between departments and can therefore be assigned in a way that allows for the most flexibility. 5. Circulation: A main circulation spine should be located between zone 4 and the rest of the spaces to complete the planning diagram for the building. This zone will also house student work display areas and lockers.

36

-

UNT CVAD Program Report


30’-0”

20’-0”

CIRCULATION

10’-0”

30’-0”

4.0 SPACE AND ADJACENCY REQUIREMENTS 4.1 SPACE PROGRAM SUMMARY 4.1.4 PLANNING MODULE DIAGRAM

-

UNT CVAD Program Report

37


4.0 SPACE AND ADJACENCY REQUIREMENTS 4.1 SPACE PROGRAM SUMMARY 4.1.5 EXTERNAL DEPARTMENT ADJACENCIES OVERVIEW PER PROGRAM NARRATIVE

The External Department Adjacency Overview Diagram per our programming efforts is intended to be a resource for the CVAD Programming Project and a reference for individual program placement as the college physically grows by renovating and adding space, and relocating departments. The diagram illustrates the required adjacencies per discipline within the CVAD collage. Our findings divided the disciplines into two buildings, The NEW CVAD Building and The Existing Art Building. The departmental adjacencies were determined from the departmental interviews, space requests, space projections and interdisciplinary interactions. The results of our assessment determined the best utilization of space would be to have the Department of Studio Art located in the New CVAD Building and The Department of Art Education and Art History as well as The Department of Design located in the Existing Art Building. The existing areas located in Hickory Hall are to remain. Additional adjacency information may be found in the Room Detail Sheets.

38

-

UNT CVAD Program Report


4.0 SPACE AND ADJACENCY REQUIREMENTS 4.1 SPACE PROGRAM SUMMARY 4.1.5 EXTERNAL DEPARTMENT ADJACENCIES OVERVIEW PER PROGRAM DIAGRAM

39


4.0 SPACE AND ADJACENCY REQUIREMENTS 4.1 SPACE PROGRAM SUMMARY 4.1.6 EXTERNAL DEPARTMENT ADJACENCIES OVERVIEW PER 2012 BUBBLE DIAGRAM - OPTION 1 NARRATIVE

The External Department Adjacency Overview Diagram, per the University’s 2012 projections, was created prior to the beginning of the CVAD Programming Project and then benchmarked to the information collected during our process. CVAD’s input was incorporated into this document and carefully considered when reviewing the overall CVAD college adjacency requirements. The discrepancies between the University’s 2012 diagram and our program findings have been indicated on The External Departmental Adjacency Overview Diagram per our Program – Option 2.

40

-

UNT CVAD Program Report


4.0 SPACE AND ADJACENCY REQUIREMENTS 4.1 SPACE PROGRAM SUMMARY 4.1.6 EXTERNAL DEPARTMENT ADJACENCIES OVERVIEW PER 2012 BUBBLE DIAGRAM - OPTION 1 (Dashed lines indicates adjacency per program interviews)

-

UNT CVAD Program Report

41


4.0 SPACE AND ADJACENCY REQUIREMENTS 4.1 SPACE PROGRAM SUMMARY 4.1.8 EXTERNAL DEPARTMENT ADJACENCIES PER 2016 REQUESTED PROGRAM - OPTION 2 NARRATIVE

Existing Art Building These diagrams depict the various permutations and combinations of the major program elements distributed throughout the three levels of the building. The diagrams are conceptual and are intended to reflect adjacency of key program areas. They are not intended to reflect exact design configurations 1. The First Level houses The Texas Fashion Collection and Fashion Design at the east end which would be serviced with direct access to the loading dock. There is an opportunity for expansion into the central unassigned space for the required storage space. The west end houses the Art History and Art Education Department Chair Suite as well as the Department of Design Chair Suite. The mechanical and electrical equipment rooms are located with the core of the building. The existing Gallery spaces are to remain. 2. The Second Level houses the main entrance to Interior Design and Communication Design at the east end with the faculty offices immediately adjacent. The additional public spaces and scholarly activity spaces can be located at the west end of the level with studios occupying the remainder. The classroom/labs at the west end are served by a double loaded central corridor to optimize plan efficiency. 3. The Third Level houses the Department of Art Education and Art History including NTIEVA and CAMCSI. The Classrooms are on the north side of the east and west wings with contiguous storage, support, and faculty offices located across the circulation corridor on the south side of the floor plate. The east end accommodates interaction / scholarly activity space. The central portion of the plan adopts a different organizational approach with the open laboratory centrally located and flanked by contiguous support and graduate student offices arrayed along the south side. New CVAD Building These diagrams depict the various permutations and combinations of the major program elements distributed throughout the three levels of the building. The diagrams are conceptual and are intended to reflect adjacency of key program areas. They are not intended to reflect exact design configurations 1. The First Level houses the Ceramics, Metalsmithing and Jewelry, Sculpture, Industrial Design programs as well as the New University Gallery Space which would all be serviced with direct access to the loading dock and accessibility to outdoor shop facilities. The IT department, mechanical and electrical equipment rooms would be located within the core of the building. 2. The Second Level houses the main entrance to New Media, Print Press and Printingmaking programs with the faculty offices immediately adjacent. The additional public spaces and scholarly activity spaces can be located at the core of the building with studio/labs occupying the remainder. The classroom/labs are served by a double loaded central corridor to optimize plan efficiency. 3. The Third through Fourth Levels houses the Photography, Drawing and Painting, and the Fibers programs as well as the Dean/Advising Suite, Studio Chair Suite and the Artist Apartment located on the top floor. The Classrooms are on the north side of the east and west wings with contiguous storage, support, and faculty offices located across the circulation corridor on the south side of the floor plate. The east end accommodates interaction / scholarly activity space. The central portion of the plan adopts a different organizational approach with the open studio/labs centrally located and flanked by contiguous support and graduate student offices arrayed along the south side. 42

-

UNT CVAD Program Report


4.0 SPACE AND ADJACENCY REQUIREMENTS 4.1 SPACE PROGRAM SUMMARY 4.1.8 EXTERNAL DEPARTMENT ADJACENCIES PER 2016 REQUESTED PROGRAM - OPTION 2 DIAGRAM

-

UNT CVAD Program Report

43


4.0 SPACE AND ADJACENCY REQUIREMENTS 4.1 SPACE PROGRAM SUMMARY 4.1.9 ALTERNATIVE PROGRAM SCENARIOS - PROPOSED REDUCTIONS

CVAD Proposed Space Reductions

6.26.13

Dept

Listed ASF

Room

Graduate Studios Overall Gallery Storage Gallery Photography Crit Rm Alt. Non Silver Processing Finishing Lab AEAH Art Ed Children/Art Classroom Art Ed Workroom Graduate Bullpen Outdoor Kiln Classrooms Omit Art History 50 seat class Ceramics Crit Room Electric Kiln Room Tech. Lab/Tool Check In/Out Drying Room Sculpture Crit Room Fab Lab Seminar/Lab Room TFC Collection Storage Conservation Lab Intake Photo Lab Visitor Center Workroom/Resource Room Non-artifact Storage Room Fashion Design/Studio/Lecture Room Interior Design Class/Lab/Studio Storage Drawing & Painting Changing Room Drawing Rooms Projection Room Industrial Design Classrooms Wood Shop Shop Crit Room Storage

44

Proposed

SF Saved

Notes

14700 Reduce from 89 to 40 4500 5000

2500 3500

1800 300 300

900 200 200

900 Reduce qty from 2 to 1 100 100

2500 500 1500 120 4500 1500

2000 400 700 0

500 100 800 120 put in Outdoor spaces 900 Reduce 0 In IT classroom space

1500 600 600 900

900 500 300 600

1800 2000 3000

900 1500 1500

900 Reduce qty from 2 to 1 500 1500

9000 900 900 400 900 600 900

2000 400 700 300 450 500 450

7000 Move 7,000 SF offsite 500 200 100 450 100 450

4500

3000

1500 Reduce qty from 3 to 2

7500 400

4500 300

3000 Reduce qty from 5 to 3 100

200 7500 600

100 4500 300

100 3000 300

9000 1500 2500 1800 1200

4500 1000 1500 900 500

4500 Reduce qty from 6 to 3 500 1000 900 Reduce qty from 2 to 1 700

0

2000 1500

600 100 300 300

-

UNT CVAD Program Report


4.0 SPACE PROGRAM AND ADJACENCY REQUIREMENTS 4.1 SPACE PROGRAM SUMMARY 4.1.9 ALTERNATIVE PROGRAM SCENARIOS - PROPOSED REDUCTIONS New Media Black Box Studio Fab Lab Communication Design Class/Lab MFA Seminar Crit Room Storage Room Dept Chair - Studio Arts Storage/Copy/Print Dept Chair - AEAH/CAMSCI/NTIEVA Storage/Copy/Print Omit Recep for CAMSCI/NTIEVA Dept Chair - Design Storage/Copy/Print Printmaking Darkroom/SprayBooth Metalsmithing Beginning Classroom Intermediate Classroom Buffing - Grinding Room Casting Room Chemical Room Consumable Material Storage Crit/Resource/Clean Room Documentation Room Enameling Hammer Machine Room Fibers Advan. Weav/Knit Supply Closet Chemical Room Computerized Weaving Studio Darkroom Digital Printing Studio Papermaking Studio Resource Room Warping Room Washout Booth Artist Apt Bathroom Bedroom Living/Kitchen/Dining Building Services Large Conference Small Conference duplicate Conference

Space Savings (ASF) -

UNT CVAD Program Report

2500 1500

2500 1500

0 Black Box to share w/ Crit Rm 0 Share Sculpture's Fab Lab

13,200 3000 1500 400

8800 1500 900 300

200

120

200 200

120 100

200

120

80

300

200

2500 2500 300 300 300 600 1500 300 600 300

2000 2000 200 200 200 500 900 200 500 200

100 0 500 500 100 100 100 100 600 100 100 100

300 300 300 300 900 900 300 600 300

200 200 200 200 500 900 200 400 200

120 240 1500

80 180 1000

40 60 500

2100 1050 800

1200 600 0

900 Reduce qty from 7 to 4 450 Reduce qty from 7 to 4 800

4400 Reduce qty from 6 to 4 1500 Reduce qty from 2 to 1 600 100 80 80 100 share reception w/ AEAH Chair

100 100 100 100 400 0 Don't have now--future request 100 200 100

63,610 45


4.1.10 ASSIGNABLE SQUARE FOOTAGE BY DEPARTMENT

Square Footage by Department 0

20000

40000

60000

80000

100000

120000

106% AEAH

662% Apartment

100% Building/College

-26% Dean Suite

-29% Dean Suite - Advising

275% Design

157% Galleries

170% IT

104% Studio Arts

159% University

Sum of Total Assignable SF 2016

46

Sum of 60% Add on Factor to 2013 ASF

Sum of Total Assignable SF 2013 -

UNT CVAD Program Report


4.1.10 SPACE ANALYSIS DIAGRAM BY DEPARTMENT 2013

1% 10%

1%

3% 5%

10%

3%

41%

3%

5% 3%

41%

29% 4%

4%

2016

1%

1%

1% 29%

1%

4%

5%

4%

3%

37%

40%

5%

-

6%

UNT CVAD Program Report

47


4.0 SPACE AND ADJACENCY REQUIREMENTS 4.1 SPACE PROGRAM SUMMARY 4.1.10 ASSIGNABLE SQUARE FOOTAGE BY PROGRAM

Square Footage by Program 0

5000

10000

15000

20000

25000

30000

AEAH Apartment Building/College CAMCSI Ceramics Comm Design Dean Suite Dean Suite - Advising Departmental Office - AEAH Departmental Office - Design Departmental Office - Studio Arts Drawing & Painting Fashion Design Fibers Galleries Industrial Design Interior Design IT Metals&Jewelry New Media NTIEVA Photography Print Press Printmaking Sculpture TFC University Sum of Total Assignable SF 2016

48

Sum of 60% Add on Factor to 2013 ASF

Sum of Total Assignable SF 2013 -

UNT CVAD Program Report


4.0 SPACE AND ADJACENCY REQUIREMENTS 4.1 SPACE PROGRAM SUMMARY 4.1.10 SPACE ANALYSIS DIAGRAM BY PROGRAM 2013

1%

6% 1%

6%

6%

6% 6%

6% 5%

6%

6%

4% 2%

6%

6%

5%

6%

2% 5%

1%

12%

5%

6% 5%

%

6%

6%

4%

4% 2%

1%

2016

1%

5% 5%

6% 4% 5%2% 4%

7%

1%

5%

6%

6%

12%

5%

4%

11% 1%

5%

10%

4% 5%

5% 4%

-

8%

7%

UNT CVAD Program Report

6%

49


4.0 SPACE AND ADJACENCY REQUIREMENTS 4.1 SPACE PROGRAM SUMMARY 4.1.10 ASSIGNABLE SQUARE FOOTAGE BY SPACE TYPE

Square Footage by Space Type 0

10000

20000

30000

40000

50000

60000

70000

80000

90000

110 Classroom Apartment Breakroom Building/College Class Lab Classroom Conference Crit GAL Gallery Grad Studio Lab Office Outdoor Reception Storage Support Sum of Total Assignable SF 2016

50

Sum of 60% Add on Factor to 2013 ASF

Sum of Total Assignable SF 2013 -

UNT CVAD Program Report


4.0 SPACE AND ADJACENCY REQUIREMENTS 4.1 SPACE PROGRAM SUMMARY 4.1.10 SPACE ANALYSIS DIAGRAM BY SPACE TYPE

1%

2013

1%

15%

15%

33%

7% 3%

33%

16% 5% 9%

5%

2016

3% 3%

1%

%

12%

5%

8%

1%

9%

5%

6% 2%

3%34% 3%

12% 5%

7% 4%

5% 2%

-

UNT CVAD Program Report

51


4.0 SPACE AND ADJACENCY REQUIREMENTS 4.1 SPACE PROGRAM SUMMARY 4.1.10 SPACE ANALYSIS DIAGRAM BY CHARACTERISTICS

15%

2016 Loud vs. Quiet

Loud VS Quiet

15%

2016 Loud vs. Quiet

38%

Loud Noisy Req. Silence Silent

Loud Loud Noisy Noisy Requires Silence Req. Silence Silent Silent

39%

39%

8%

8%

15%

Clean VS Dirty

Dirty Loud Combination Noisy Clean Req. Silence Silent

39% 8% 52

-

UNT CVAD Program Report


4.0 SPACE AND ADJACENCY REQUIREMENTS 4.1 SPACE PROGRAM SUMMARY 4.1.10 SPACE ANALYSIS DIAGRAM BY ENROLLMENT Undergraduate VS Graduate Enrollment

d d A

rt a ch

?

d d A

-

UNT CVAD Program Report

rt a ch

53


DESIGN

DEPARTMENTS

STUDIO ARTS

{

GENERAL

Department Chair Suite: AEAH AEAH

Department Chair Suite: Design Communication Design Fashion Fibers Interior TFC

Department Chair Suite: Studio Arts Ceramics Drawing and Painting Industrial Metalsmithing and Jewelry New Media Photography Printmaking Print Press Sculpture

Across all Programs Building / College

DEAN ADVISING SUITE

Dean Advising Suite

SHARED SPACES

Artist Apartment Gallery IT

NON-DEPARTMENT

54

{ { {

{

{{ { {

AEAH CAMSCI NTIEVA

-

UNT CVAD Program Report


4.1 EXISTING + CVAD

The University of North Texas

UNT CVAD includes three departments: AEAH, Studio Arts and Design. Each department is made up of multiple programs. In addition, there are shared spaces and general spaces as listed in the following pages. The Dean’s Suite, Advising and Department Head suites are listed in their own category. The Programs are listed above and a detailed list of all the spaces can be found on the next pages. Every room in each program is described in more detail and grouped by department.

-

UNT CVAD Program Report

55


ROOM LIST GENERAL

Across all Programs Dean Associate Dean Budget Officer Faculty Office / Staff Department Chair / Director Adjunct Office Admin / Clerical Tech Graduate Studios Building / College Visual Program Space Program R.D.S. /Plans: Main Lobby Large Conference Room Small Conference Room Faculty Break room Cafe Wellness / Mother’s Room Loading Dock Recycling and Vending Custodial

DEAN ADVISING SUITE

Dean Advising Suite Department Adjacencies Visual Program Space Program R.D.S. & Plan Dean Associate Dean Faculty Office Budget Officer Admin / Clerical Dean Reception Area Advising Reception Area Break Room Conference Room Mail Room Copy/Print/Storage

SHARED

Artist Apt Department Adjacencies Visual Program Space Program R.D.S. & Plan Bathroom Bedroom Living Terrace Gallery Department Adjacencies Visual Program Space Program R.D.S. & Plan Faculty Office Tech *Existing North *Existing Light well *Existing Reception Gallery /Foyer *Existing Main New CVAD Gallery *Existing Storage Room Storage Room - New Building IT Department Adjacencies Visual Program Space Program R.D.S. & Plan Faculty Office Adjunct Office General Classroom General Access Lab General Computer Lab Main Suite Server Room Storage Equipment Storage Checkout

AEAH

AEAH: CAMSCI / NTIEVA Department Chair Suite Department Adjacencies Visual Program Space Program R.D.S.: / Plans: Department Chair / Director Faculty Office Admin / Clerical Reception Area Conference Room Storage/Copy/Print Room AEAH Department Adjacencies Visual Program Space Program R.D.S. & Plan Faculty Office Adjunct Office Graduate Bullpen Outdoor Kiln Yard Multi-Purpose Seminar/Class Art Ed. Children and Art Class Art Ed. Individual Restroom Art Ed. Workroom Storage Room Print Room

DESIGN

Design Department Chair Suite: Department Adjacencies Visual Program Space Program R.D.S. & Plan Department Chair / Director Tech Reception Area Conference Room Storage/Copy/Print Room Communication Design Department Adjacencies Visual Program Space Program R.D.S. & Plan Faculty Offices Class/Lab MFA Seminar Special Class/Lab/Studio Grad Studio Render Farm Spray Room Clean Up/Darkroom Critique Room Resource Room Storage Room Fashion Department Adjacencies Visual Program Space Program R.D.S. & Plan Faculty Office Design Studio/Lecture Special Class Lab/Lecture Knitting Studio CAD Studio Room Graduate Studio Critique Room Sewing Production Workroom Storage Room Fibers Department Adjacencies Visual Program Space Program R.D.S. & Plan Faculty Office Admin / Clerical Critique/Lecture Room Grad Studios Weaving 1 Studio Advanced Weaving Studio Computerized Weaving Studio Digital Printing Studio Knitting/Sewing Off-Loom Weaving

Paper making Studio

56

-

UNT CVAD Program Report


Screen Print/Surface Design Surface Design Studio Washout Booth Darkroom Exposure Unit Room Chemical Room Warping Room Resource Room Advanced Weaving Supply Closet

Industrial Design Department Adjacencies Visual Program Space Program R.D.S. & Plan Faculty Office Class/Lab/Studio Graduate Studio Wood Shop Shop Critique Room Storage Room Interior Design Department Adjacencies Visual Program Space Program R.D.S. & Plan Faculty Office Tech Class/Lab/Studio Graduate Studio Critique/Lighting Lab Storage Room Copy Room Resource Room TFC Department Adjacencies Visual Program Space Program R.D.S. & Plan Faculty Offices Seminar Room Gallery Visitors’ Welcome Center Photography Lab Conservation Lab Workroom/Resource Room Intake Room Collection Storage

-

STUDIO ARTS

Studio Arts Department Chair Suite

Department Adjacencies Visual Program Space Program R.D.S.: / Plans: Department Chair / Director Admin / Clerical Reception Area Conference Room Storage/Copy/Print Room Ceramics Department Adjacencies Visual Program Space Program R.D.S. & Plan Faculty Office Tech Critique/Seminar Room Graduate Studio Advanced Major Lab Hand Building Lab Technical Lab/Tool Check In/Out

Wheel Throwing Lab Covered Outdoor Kiln Pad Outdoor Fabrication Storage Area

Electric Kiln Room Clay Mixing Room Glaze Chemical Mixing Room Drying Room Bulk Clay Storage Room Drawing and Painting Department Adjacencies Visual Program Space Program R.D.S. & Plan Faculty Office Adjunct Office Critique/Seminar Room Drawing Room Painting Room Graduate Studio Projection Room Spray Booth Changing Room Storage Room Supply Room Metalsmithing and Jewelry Department Adjacencies Visual Program Space Program R.D.S. & Plan Faculty Office Beginning Classroom Intermediate Classroom Graduate Studio

UNT CVAD Program Report

Courtyard Studio - Outdoor Buffing - Grinding Room Casting Room Chemical Room Documentation Room Critique/Resource/Clean Room Enameling Room Hammer Machine Room Consumable Material Storage New Media Department Adjacencies Visual Program Space Program R.D.S. & Plan Faculty Office Adjunct Office Critique/Seminar Room Graduate Studio Black Box Studio Computer Lab Physical Computing lab Fabrication Lab Media Equipment Room Photography Department Adjacencies Visual Program Space Program R.D.S. & Plan Faculty Office Adjunct Office Tech Critique/Seminar Room Graduate Studio Grad./Advanced Digital Printing Lighting Studio Undergraduate. Digital Printing Alt... Non-Silver Process Studio

Acid Etching and Spray Booth Darkroom/Spray Booth Room Washout Room Print Press Department Adjacencies Visual Program Space Program R.D.S. & Plan Faculty Office Letterpress Studio Screen/Intaglio Studio Intaglio/Relief Studio Lithography Studio Wood Shop Collection Room Darkroom/Washout Gallery Meeting Area Storage Room Sculpture Department Adjacencies Visual Program Space Program R.D.S. & Plan Faculty Office Adjunct Office Tech Seminar/Lab Room Graduate Studios Courtyard Shop/Foundry/Welding

Wood Shop Fab Lab Critique Room Slurry Room Tool Check-In/Out

Common Area/Film Processing Lab

Finishing Room Main Darkroom Special Purpose Darkroom Chemical Storage/Mixing Room Maintenance Storage Room Lighting Studio Storage Photo Storage Room Printmaking Department Adjacencies Visual Program Space Program R.D.S. & Plan Faculty Office Graduate Studio Etching Relief Studio Screen print/Books/Digital Process

Lithography Studio Critique and Archive Space Storage Room

Notes: 1. Rooms listed in grey are common amongst all programs and therefore shown under the “general” section. 2. R.D.S. = Room Detail Sheet 3. “ * ” Existing Spaces where R.D.S. and Plan are not included 57


UNT CVAD 4.0 SPACEProgramming AND ADJACENCY REQUIREMENTS Strategic 4.3 DEPARTMENT PROGRAM 4.2.3 SPACE LIST CONCISE SUMMARY SPACE LISTPROGRAM - CONCISE SUMMARY SPACE NAME

2013 Department

2016

Assignable S/F

Gross S/F

Bubble Diag.

Assignable S/F

Gross S/F

Assignable S/F

CONCISE SUMMARY Department Name Dean-Advising Suite Print Press Gallery IT AEAH NTIEVA CMCSI Photography Printmaking Ceramics Metalsmithing and Jewelry Sculpture Fibers TFC Fashion Design Interior Design Drawing and Painting Industrial Design New Media Communication Design Outdoor Spaces Building / College Department Chair- Studio Arts Department Chair- AEAH Department Chair-Design Artist Apartment

Grand Totals

5,459 5,132 6,099 5,470 5,406 5,238 5,662 6,093 4,348 5,597 5,998 5,935 4,094 4,509 11,399 0 1,855 5,474 0 0 494 832 782 244

9,925 9,330 11,089 9,945 9,829 9,523 10,294 11,078 7,905 10,176 10,905 10,790 7,443 8,198 20,725 0 3,373 9,952 0 0 898 1,513 782 444

3,980 4,960 15,697 14,665 11,355 9,710 8,930 11,195 9,490 14,090 15,155 17,120 11,300 9,950 22,875 19,010 11,225 26,215 0 7,430 770 1,490 770 1,860

7,236 9,018 28,539 26,662 20,645 17,654 16,236 20,354 17,254 25,617 27,553 31,126 20,545 18,090 41,589 34,562 20,408 47,661 0 13,508 1,400 2,709 1,400 3,382

0 0 0 5,682 5,000 10,991 6,300 17,580 6,810 7,225 8,500 8,500 8,500 6,951 10,000 7,000 8,000 22,225 8,500 5,000 6,500 0 0 1,000 18,060 1,379 0

96,120

174,116

249,242

453,147

179,703 326,718

58

-

UNT CVAD Program Report


-

UNT CVAD Program Report

59


GENERAL Across all Programs Dean Associate Dean Budget Officer Faculty Office / Staff Department Chair / Director Adjunct Office Admin / Clerical Tech Graduate Studios

Building / College Visual Program Space Program R.D.S. /Plans: Main Lobby Large Conference Room Small Conference Room Faculty Break room Cafe Wellness / Mother’s Room Loading Dock Recycling and Vending Custodial

Notes: 1. Rooms listed in grey are common amongst all programs and therefore shown under the “general” section. 2. R.D.S. = Room Detail Sheet 3. “ * ” Existing Spaces where R.D.S. and Plan are not included

60

-

UNT CVAD Program Report


4.2 GENERAL SPACES Departments

The University of North Texas


The University of North Texas


4.2.1 Across all Programs

The University of North Texas


4.2.1 GENERAL: ACROSS ALL PROGRAMS DEAN’S OFFICE ROOM DETAIL SHEET

Room Detail Sheet : Dean’s Advising Suite – Dean’s Office

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable

ASSIGNABLE SQ. FOOTAGE: 220

TYPE OF ARTIFICIAL LIGHTING: Standard

ROOM DIMENSIONS: 12’ x 18’

POWER: 6 outlets along desk wall

NUMBER OF OCCUPANTS: 1

EMERGENCY POWER (yes / no, qty.): No

UTILIZATION: Monday – Friday 8-5

DATA (qty & type); 2 Data outlets.

IS ROOM SHARED WITH OTHERS? No

VOICE (qty & type): 1 phone

RESOURCES SHARED WITH OTHERS: No

AUDIOVISUAL (qty & type): No

ADJACENCIES (internal & external): AEAH Chair, Printer Room

PIPED SERVICES: No

WINDOWS / NATURAL LIGHT: Yes

WATER / FLOOR DRAIN: No

ACOUSTICS: Privacy, quiet; ability to have confidential conversations

TEMPERATURE: controllable, no need for individual control, just want to have consistency

SIGHTLINES: No

HUMIDITY: low to medium

MIN. DOOR WIDTH & DESCRIPTION: Standard

VENTILATION: standard

ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling:

AIR CHANGES: No

MIN. CEILING HEIGHT: 10’

HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: Locate all faculty near each other No shared offices

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): A. Laminate or veneer desk. B. 2 Standard file cabinets under work surface C. Painted, metal Filing, Laminate filing, or veneer filing D. Upper bins or shelves with under mounted lighting or a hutch with storage and under mounted lighting E. Optional keyboard tray F. 36”-48” Small conference table G. 2 Optional storage pieces in laminate or veneer H. 1 Task chair I. 2 Guest chairs J. 3-4 Conference chairs

64

-

UNT CVAD Program Report


4.2.1 GENERAL: ACROSS ALL PROGRAMS DEAN’S OFFICE ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

65


4.2.1 GENERAL: ACROSS ALL PROGRAMS ASSOCIATE DEAN ROOM DETAIL SHEET

Room Detail Sheet : Dean’s Suite-Advising Associate Dean

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 200 ROOM DIMENSIONS: 12’ x 16.5’ NUMBER OF OCCUPANTS: 1

UTILIZATION (hours/day and general time of day): 5 days a week, 8 AM-6 PM or later, some Saturdays and Sundays as needed IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Advising Offices WINDOWS / NATURAL LIGHT: Yes ACOUSTICS: Privacy SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling: MIN. CEILING HEIGHT: Standard

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Task, standard overhead fluorescent POWER (qty & type): Multiple outlets, wireless throughout EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Provide Category 6A cable to all offices, open reception/work area, conference room and copy/print room. Provide Category 6A cable to support Wireless connectivity throughout. Provide Category 6A cable to support Audio Visual systems. VOICE (qty & type): Provide Category 6A cables to support voice connectivity in all offices and open reception. AUDIOVISUAL (qty & type): Conference Room - Wide aspect ratio HD display(s). Simple, intuitive control system. High quality audio system with listen assist. Digital video and audio inputs. PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No

FURNITURE, FIXTURES & EQUIPMENT

SPECIAL REQUIREMENTS / NOTES: Daylight as much as possible for all

MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): A. 1 10w’ x 13d’ L-shaped workstation B. 1 Task chair C. 2 Guest chairs

66

-

UNT CVAD Program Report


4.2.1 GENERAL: ACROSS ALL PROGRAMS ASSOCIATE DEAN ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

67


4.2.1 GENERAL: ACROSS ALL PROGRAMS BUDGET OFFICER ROOM DETAIL SHEET

Room Detail Sheet : Dean’s Suite – Budget Officer

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 100 ROOM DIMENSIONS: 10’ x 10’ NUMBER OF OCCUPANTS: 1 UTILIZATION (hours/day and general time of day): 8:00 – 5:00 M - F IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Dean Reception Area, Advising reception Area, Mail Room, Copy/Print/Storage Room WINDOWS / NATURAL LIGHT: Yes ACOUSTICS: Privacy SIGHTLINES: N/A MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling: MIN. CEILING HEIGHT: 10’

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard POWER (qty & type): Standard outlets spaced according to code. EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Provide Category 6A cable to support data network connections and to support Wireless connectivity. VOICE (qty & type): Provide Category 6A cable to support voice connectivity. AUDIOVISUAL (qty & type): No PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: Furniture walls can be higher than typical.

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): A. Laminate work surface with return and credenza B. Optional 2 high painted or laminate lateral file C. 2 Standard file cabinets under work surface D. Optional upper bins or shelves with under mounted lighting E. Optional hutch with overhead storage and under mounted lighting. F. Optional Keyboard tray G. 1 Task chair H. 2 Guest chairs

68

-

UNT CVAD Program Report


4.2.1 GENERAL: ACROSS ALL PROGRAMS BUDGET OFFICER ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

69


4.2.1 GENERAL: ACROSS ALL PROGRAMS FACULTY OFFICE ROOM DETAIL SHEET

Room Detail Sheet : Faculty Office

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 13

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable

ASSIGNABLE SQ. FOOTAGE: 130

TYPE OF ARTIFICIAL LIGHTING: Overhead

ROOM DIMENSIONS: 10’ x 13’

POWER: 6 outlets along desk wall

NUMBER OF OCCUPANTS: Reference Space Program

EMERGENCY POWER (yes / no, qty.): No

UTILIZATION: Monday – Friday 8-5

DATA (qty & type); 6 to 8 computer with internet and all the software that is normal for an Art staff computer.

IS ROOM SHARED WITH OTHERS? No

VOICE (qty & type): 1 phone RESOURCES SHARED WITH OTHERS: AEAH Faculty, CAMCSI and NTIEVA

AUDIOVISUAL (qty & type): No

ADJACENCIES (internal & external): AEAH Chair, Printer Room

PIPED SERVICES: No

WINDOWS / NATURAL LIGHT: Yes

WATER / FLOOR DRAIN: No

ACOUSTICS: quiet; ability to have confidential conversations

TEMPERATURE: controllable, no need for individual control, just want to have consistency

SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: carpet Base: rubber Walls: paint Ceiling: tile MIN. CEILING HEIGHT: 10’

HUMIDITY: low to medium VENTILATION: standard AIR CHANGES: No HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: Locate all faculty near each other No shared offices

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): (1) Desk with return, (4) 5-high bookcases, (3) guest chairs, (1) task chair, (1) Small meeting table

70

-

UNT CVAD Program Report


4.2.1 GENERAL: ACROSS ALL PROGRAMS FACULTY OFFICE ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

71


4.2.1 GENERAL: ACROSS ALL PROGRAMS DEPARTMENT CHAIR ROOM DETAIL SHEET

Room Detail Sheet : Department Chair Suite – Chairperson Office

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 170 ROOM DIMENSIONS: 12’ x 14’ NUMBER OF OCCUPANTS: 1 UTILIZATION (hours/day and general time of day): 8:00 – 5:00 M - F IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Dean’s Suite WINDOWS / NATURAL LIGHT: No ACOUSTICS: Privacy SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floors: Base: Walls: Ceiling: MIN. CEILING HEIGHT: 10’

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard overhead fluorescent POWER (qty & type): Standard outlets spaced according to code. EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): 2 Data outlets. Provide Category 6A cable from the Telecom Room. Provide Category 6A cable to support wireless network coverage. VOICE (qty & type): 1 phone – Provide Category 6A cable from the Telecom Room to support voice connectivity. AUDIOVISUAL (qty & type): No PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: All departmental chairs are now being combined to one suite.

BUILT-IN (qty & type): N/A FURNITURE (qty & type): 3 desks, 3 desk chairs, 6 guest chairs, 6 lateral file cabinets, 3 bookcases

72

-

UNT CVAD Program Report


4.2.1 GENERAL: ACROSS ALL PROGRAMS DEPARTMENT CHAIR ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

73


4.2.1 GENERAL: ACROSS ALL PROGRAMS ADJUNCT OFFICE ROOM DETAIL SHEET

Room Detail Sheet : Adjunct Office

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable

ASSIGNABLE SQ. FOOTAGE: 65

TYPE OF ARTIFICIAL LIGHTING: Overhead

ROOM DIMENSIONS: 6.5 x 10

POWER: 6 outlets along desk wall

NUMBER OF OCCUPANTS: Reference Space Program

EMERGENCY POWER (yes / no, qty.): No

UTILIZATION: Monday – Friday 8-5

DATA (qty & type); 6 to 8 computer with internet and all the software that is normal for an Art staff computer.

IS ROOM SHARED WITH OTHERS? No RESOURCES SHARED WITH OTHERS: AEAH Faculty ADJACENCIES (internal & external): AEAH Chair, Printer Room WINDOWS / NATURAL LIGHT: Yes ACOUSTICS: quiet; ability to have confidential conversations

VOICE (qty & type): 1 phone AUDIOVISUAL (qty & type): No PIPED SERVICES: No WATER / FLOOR DRAIN: No

SIGHTLINES: No

TEMPERATURE: controllable, no need for individual control, just want to have consistency

MIN. DOOR WIDTH & DESCRIPTION: Standard

HUMIDITY: low to medium

ROOM FINISHES: Standard U.N.O. Floor: carpet Base: rubber Walls: paint Ceiling: tile

VENTILATION: standard

MIN. CEILING HEIGHT: 10’

SPECIAL REQUIREMENTS / NOTES:

AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): (1) Table desk, (1) mobile ped, (2) guest chairs, (1) task chair

74

-

UNT CVAD Program Report


4.2.1 GENERAL: ACROSS ALL PROGRAMS ADJUNCT OFFICE ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

75


4.2.1 GENERAL: ACROSS ALL PROGRAMS ADMINISTRATIVE / CLERICAL OFFICE ROOM DETAIL SHEET

Room Detail Sheet : Admin / Clerical Office

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable

ASSIGNABLE SQ. FOOTAGE: 60

TYPE OF ARTIFICIAL LIGHTING: Overhead

ROOM DIMENSIONS: 6 x 10

POWER: 6 outlets along desk wall

NUMBER OF OCCUPANTS: Reference Space Program

EMERGENCY POWER (yes / no, qty.): No

UTILIZATION: Monday – Friday 8-5

DATA (qty & type); 6 to 8 computer with internet and all the software that is normal for an Art staff computer.

IS ROOM SHARED WITH OTHERS? No RESOURCES SHARED WITH OTHERS: AEAH Faculty ADJACENCIES (internal & external): AEAH Chair, Printer Room WINDOWS / NATURAL LIGHT: Yes ACOUSTICS: quiet; ability to have confidential conversations

VOICE (qty & type): 1 phone AUDIOVISUAL (qty & type): No PIPED SERVICES: No WATER / FLOOR DRAIN: No

SIGHTLINES: No

TEMPERATURE: controllable, no need for individual control, just want to have consistency

MIN. DOOR WIDTH & DESCRIPTION: Standard

HUMIDITY: low to medium

ROOM FINISHES: Standard U.N.O. Floor: carpet Base: rubber Walls: paint Ceiling: tile

VENTILATION: standard

MIN. CEILING HEIGHT: 10’

SPECIAL REQUIREMENTS / NOTES:

AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): (1) Table desk, (1) mobile ped, (2) guest chairs, (1) task chair

76

-

UNT CVAD Program Report


4.2.1 GENERAL: ACROSS ALL PROGRAMS ADMINISTRATIVE / CLERICAL OFFICE ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

77


4.2.1 GENERAL: ACROSS ALL PROGRAMS TECH OFFICE ROOM DETAIL SHEET

Room Detail Sheet : Tech

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 35 ROOM DIMENSIONS: 5’ x 7’ NUMBER OF OCCUPANTS: Reference Space Program

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard overhead fluorescent POWER (qty & type): EMERGENCY POWER (yes / no, qty.): No

UTILIZATION (hours/day and general time of day): Standard access

DATA (qty & type): No

IS ROOM SHARED WITH OTHERS? (list group(s)): No

VOICE (qty & type): No

RESOURCES SHARED WITH OTHERS: No

AUDIOVISUAL (qty & type): No

ADJACENCIES (internal & external):

PIPED SERVICES: No

WINDOWS / NATURAL LIGHT: Yes

WATER / FLOOR DRAIN: No

ACOUSTICS: Standard

TEMPERATURE: Standard

SIGHTLINES: No

HUMIDITY: Standard

MIN. DOOR WIDTH & DESCRIPTION: Standard

VENTILATION: Standard

ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling:

AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES:

MIN. CEILING HEIGHT: 10’

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): (A) Desk, (B) Chair

78

-

UNT CVAD Program Report


4.2.1 GENERAL: ACROSS ALL PROGRAMS TECH OFFICE ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

79


4.2.1 GENERAL: ACROSS ALL PROGRAMS GRADUATE STUDIO ROOM DETAIL SHEET

Room Detail Sheet : Graduate Studio SPACE REQUIREMENTS

BUILDING SYSTEM REQUIREMENTS

ROOM QUANTITY: 1

SECURITY: Standard

ASSIGNABLE SQ. FOOTAGE: 300

TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard overhead fluorescent

ROOM DIMENSIONS: 15’ x 20’ NUMBER OF OCCUPANTS: Reference Space Program UTILIZATION (hours/day and general time of day): 8-5, M-F IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Advanced Major Lab WINDOWS / NATURAL LIGHT: Yes

POWER (qty & type): 120v x 9 outlets EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): No VOICE (qty & type): No AUDIOVISUAL (qty & type): No PIPED SERVICES: No

ACOUSTICS: Sound dampening

WATER / FLOOR DRAIN: 1 Stainless steel sink with floor drain and cleanable trap

SIGHTLINES: No

TEMPERATURE: Standard

MIN. DOOR WIDTH & DESCRIPTION: 3’ 6”

HUMIDITY: Dry

ROOM FINISHES: Standard U.N.O. Floor: Sealed concrete Base: Walls: Ceiling:

VENTILATION: Standard

MIN. CEILING HEIGHT: 10’

AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES:

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): N/A e

80

-

UNT CVAD Program Report


4.2.1 GENERAL: ACROSS ALL PROGRAMS GRADUATE STUDIO ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

81



4.2.2 BUILDING / COLLEGE

The University of North Texas

The New CVAD Building will provide a variety of open and community spaces for faculty and students to enjoy. Amenities such as faculty break rooms, conference rooms, a Café’, and a Wellness/Mother’s Room will enhance the interaction between all disciplines.


4.2.2 GENERAL BUILDING / COLLEGE PROGRAM ADJACENCY DIAGRAM

84

-

UNT CVAD Program Report


4.2.2 GENERAL BUILDING / COLLEGE PROGRAM ADJACENCY DIAGRAM Space Name

2013 Position

Circulation Room Factor Number

2016

Number of Spaces

Assignable S/F

Number of Spaces

Unit Area

Total Area

Building / College Main Lobby Large Conference Room Small Conference Room Faculty Breakroom CafĂŠ Wellness/Mothers Room Lockers Loading Dock Recycling/Vending Custodial Total Spaces Assignable Square Feet Net to Gross @ 45% = Assignable SF x (1/(1-45%))= Department Gross SF

-

UNT CVAD Program Report

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

0 0 0 0 0 0 0 0 0 0

0 0 0 0 0 0 0 0 0 0

0 0.8181

2 7 7 2 1 2 2 2 2 2

400 300 150 600 600 120 200 200 120 200

800 2,100 1,050 1,200 600 240 400 400 240 400

29 0 0

7,430 6,078

0

13,508

85


4.2.2 GENERAL: BUILDING / COLLEGE MAIN LOBBY ROOM DETAIL SHEET

Room Detail Sheet : Main Lobby

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 2

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable

ASSIGNABLE SQ. FOOTAGE: 400

TYPE OF ARTIFICIAL LIGHTING: Overhead

ROOM DIMENSIONS: 20’ x 20’

POWER: Convenience outlets

NUMBER OF OCCUPANTS:

EMERGENCY POWER (yes / no, qty.): No

UTILIZATION: Monday – Friday 8-5

DATA (qty & type): Provide Category 6A cable to support Wireless connectivity in the Main Lobby. Provide Category 6A cable to support Audio Visual systems.

IS ROOM SHARED WITH OTHERS? Other programs in building RESOURCES SHARED WITH OTHERS: N/A ADJACENCIES (internal & external): N/A WINDOWS / NATURAL LIGHT: Yes ACOUSTICS: N/A SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling: MIN. CEILING HEIGHT: 10’

VOICE (qty & type): Provide Category 6A cable to support a courtesy phone (if required). AUDIOVISUAL (qty & type): Display Screens PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Standard AIR CHANGES: No HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES:

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type):

BUILT-IN (qty & type): Reception Desk FURNITURE (qty & type): A. Table B. Lounge Seating C. Chair

86

-

UNT CVAD Program Report


4.2.2 GENERAL: BUILDING / COLLEGE MAIN LOBBY ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

87


4.2.2 GENERAL: BUILDING / COLLEGE LARGE CONFERENCE ROOM ROOM DETAIL SHEET

Room Detail Sheet : Large Conference Room

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 7

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable

ASSIGNABLE SQ. FOOTAGE: 300 x 7 = 2100

TYPE OF ARTIFICIAL LIGHTING: Overhead

ROOM DIMENSIONS:15’ x 20’

POWER: Outlets, Ceiling outlet for projector / screen, floor core to distribute power/data to table

NUMBER OF OCCUPANTS: 10 UTILIZATION: Monday – Friday 8-5 IS ROOM SHARED WITH OTHERS? Other programs in building RESOURCES SHARED WITH OTHERS: ADJACENCIES (internal & external): N/A WINDOWS / NATURAL LIGHT: No ACOUSTICS: Ability to have confidential meetings SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling: MIN. CEILING HEIGHT: 10’

EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Provide Category 6A cable to support video conference via Skype and to support Wireless connectivity in the space. VOICE (qty & type): Provide Category 6A cable to support audio conferencing (Polycom) in the space. AUDIOVISUAL (qty & type): Dual wide aspect ratio projection screens with high definition projectors. Simple, intuitive control system. High quality audio system with listen assist. Digital video and audio inputs at Presenter location. Web camera and room microphone for Skype sessions. PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Standard AIR CHANGES: No HAZARDOUS MATERIALS & STORAGE METHOD: No

FURNITURE, FIXTURES & EQUIPMENT

SPECIAL REQUIREMENTS / NOTES:

MOBILE (qty & type): Artwork BUILT-IN (qty & type): Projection screen Credenza FURNITURE (qty & type): A. Tables B. Chairs

88

-

UNT CVAD Program Report


4.2.2 GENERAL: BUILDING / COLLEGE LARGE CONFERENCE ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

89


4.2.2 GENERAL: BUILDING / COLLEGE SMALL CONFERENCE ROOM ROOM DETAIL SHEET

Room Detail Sheet : Small Conference Room

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 7

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable

ASSIGNABLE SQ. FOOTAGE: 150

TYPE OF ARTIFICIAL LIGHTING: Overhead

ROOM DIMENSIONS: 10’ x 15’’

POWER: Convenience outlets and floor core to distribute power/data to table

NUMBER OF OCCUPANTS: 3 - 5 UTILIZATION: Monday – Friday 8-5 IS ROOM SHARED WITH OTHERS? Other programs in building RESOURCES SHARED WITH OTHERS: N/A ADJACENCIES (internal & external): N/A WINDOWS / NATURAL LIGHT: No ACOUSTICS: N/A SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling: MIN. CEILING HEIGHT: 10’

EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Provide Category 6A cable to support video conferencing (Skype) and Wireless connectivity. VOICE (qty & type): Provide Category 6A cable to support audio conferencing (Polycom). AUDIOVISUAL (qty & type): Wide aspect ratio HD display(s). Simple, intuitive control system. High quality audio system with listen assist. Digital video and audio inputs. PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Standard AIR CHANGES: No HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES:

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): FURNITURE (qty & type): (A) Conference table with power (B) 4 conference chairs

90

-

UNT CVAD Program Report


4.2.2 GENERAL: BUILDING / COLLEGE SMALL CONFERENCE ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

91


4.2.2 GENERAL: BUILDING / COLLEGE FACULTY BREAK ROOM ROOM DETAIL SHEET

Room Detail Sheet : Faculty Breakroom

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 2 ASSIGNABLE SQ. FOOTAGE: 600 x 2 = 1200 ROOM DIMENSIONS: 20’ x 30’ NUMBER OF OCCUPANTS: UTILIZATION (hours/day and general time of day): M-F 8-5 IS ROOM SHARED WITH OTHERS? (list group(s)): Shared with faculty from various programs to meet and collaborate RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): No WINDOWS / NATURAL LIGHT: Yes ACOUSTICS: Standard SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling: MIN. CEILING HEIGHT: 12 ‘

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard POWER (qty & type): Outlet for microwaves, and outlets for faculty to plug in laptop at tables EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Provide Category 6A cable to support Wireless connectivity in the space. VOICE (qty & type): No AUDIOVISUAL (qty & type): No PIPED SERVICES: Sink WATER / FLOOR DRAIN: Yes TEMPERATURE: Standard HUMIDITY: No VENTILATION: HVAC, exhaust for food smell AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES:

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A

Trashcan Recycling Bin BUILT-IN (qty & type): Counter Space with Sink FURNITURE (qty & type): A. Tables B. Chairs EQUIPMENT (qty & type): C. Vending Machine D. Coke Machine E. 2 Microwaves F. Coffee Vending Machine

92

-

UNT CVAD Program Report


4.2.2 GENERAL: BUILDING / COLLEGE FACULTY BREAK ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

93


4.2.2 GENERAL: BUILDING / COLLEGE CAFE ROOM DETAIL SHEET

Room Detail Sheet : Cafe

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable

ASSIGNABLE SQ. FOOTAGE: 600

TYPE OF ARTIFICIAL LIGHTING: Overhead

ROOM DIMENSIONS: 20’ x 30’

POWER: 15 outlets + Equipment

NUMBER OF OCCUPANTS: 15

EMERGENCY POWER (yes / no, qty.): No

UTILIZATION: Monday – Friday 8-5

DATA (qty & type): Category 6A cable to support Wireless connectivity in the space.

IS ROOM SHARED WITH OTHERS? Other Programs. RESOURCES SHARED WITH OTHERS:

VOICE (qty & type): No

ADJACENCIES (internal & external): Central to all Departments.

AUDIOVISUAL (qty & type): Audio system for high quality background sound playback with auxiliary input

WINDOWS / NATURAL LIGHT: Yes ACOUSTICS: Standard SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling: MIN. CEILING HEIGHT: 10’

PIPED SERVICES: Yes WATER / FLOOR DRAIN: Sink and Floor drain in Kitchen Area TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Standard AIR CHANGES: No HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES:

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): Trashcan BUILT-IN (qty & type): Countertop with Shelving above. Millwork with Point of Sales Station Display Case for Snacks. FURNITURE (qty & type):

A. Chair B. Table C. Shelves EQUIPMENT (qty & type):

D. Coffee Machine E. Display Case F. Cash Register G. Dishwasher

94

-

UNT CVAD Program Report


4.2.2 GENERAL: BUILDING / COLLEGE CAFE ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

95


4.2.2 GENERAL: BUILDING / COLLEGE WELLNESS / MOTHER’S ROOM ROOM DETAIL SHEET

Room Detail Sheet : Wellness / Mother's Room

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 2

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable

ASSIGNABLE SQ. FOOTAGE: 120 x 2 = 240

TYPE OF ARTIFICIAL LIGHTING: Overhead

ROOM DIMENSIONS: 10’ x 12’ each

POWER: Convenience outlets.

NUMBER OF OCCUPANTS:

EMERGENCY POWER (yes / no, qty.): No

UTILIZATION: Monday – Friday 8-5

DATA (qty & type): Provide Category 6A cable to support Wireless connectivity in the space.

IS ROOM SHARED WITH OTHERS? Other programs in building RESOURCES SHARED WITH OTHERS: N/A ADJACENCIES (internal & external): N/A WINDOWS / NATURAL LIGHT: No ACOUSTICS: N/A SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling: MIN. CEILING HEIGHT: 10’

VOICE (qty & type): N/A AUDIOVISUAL (qty & type): N/A PIPED SERVICES: Yes WATER / FLOOR DRAIN: Yes TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Standard AIR CHANGES: No HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES:

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A Plants BUILT-IN (qty & type): Credenza FURNITURE (qty & type): A. Sofa B. Table

96

-

UNT CVAD Program Report


4.2.2 GENERAL: BUILDING / COLLEGE WELLNESS / MOTHER’S ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

97


4.2.2 GENERAL: BUILDING / COLLEGE LOADING DOCK ROOM DETAIL SHEET

Room Detail Sheet : Loading Dock

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 600 ROOM DIMENSIONS: 15’x25’ NUMBER OF OCCUPANTS: 10-15 UTILIZATION (hours/day and general time of day): M-F 8-5

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard POWER (qty & type): 220 v outlets for fork life charging area and regular 110 v outlets EMERGENCY POWER (yes / no, qty.): No

IS ROOM SHARED WITH OTHERS? (list group(s)): Shared with faculty from various programs.

DATA (qty & type): Provide Category 6A cable to support Wireless connectivity at the loading dock. Provide enclosure rated for the environment.

RESOURCES SHARED WITH OTHERS: No

VOICE (qty & type): No

ADJACENCIES (internal & external): No

AUDIOVISUAL (qty & type): N/A

WINDOWS / NATURAL LIGHT: No

PIPED SERVICES: Utility Sink

ACOUSTICS: Yes for 18 wheeler and overhead door noise.

WATER / FLOOR DRAIN: Yes

SIGHTLINES: No

TEMPERATURE: Concern of conditioned air loss due to overhead coiling door when it is open to receive deliveries.

MIN. DOOR WIDTH & DESCRIPTION: 3’ 6” and Overhead Coiling Door and Standard ROOM FINISHES: Standard U.N.O. Floor: Concrete Industrial Base: Walls: Wainscot Ceiling:

HUMIDITY: N/A VENTILATION: Standard AIR CHANGES: High conditioned air loss during loading / unloading when overhead coiling door is open. HAZARDOUS MATERIALS & STORAGE METHOD: No

MIN. CEILING HEIGHT: 10 ‘

SPECIAL REQUIREMENTS / NOTES

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): FURNITURE (qty & type)

98

-

UNT CVAD Program Report


4.2.2 GENERAL: BUILDING / COLLEGE LOADING DOCK ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

99


4.2.2 GENERAL: BUILDING / COLLEGE RECYCLING / VENDING ROOM DETAIL SHEET

Room Detail Sheet : Recycling / Vending

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 2

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable

ASSIGNABLE SQ. FOOTAGE: 120 x 2 = 240

TYPE OF ARTIFICIAL LIGHTING: Overhead

ROOM DIMENSIONS: 10’ x 12’

POWER: Convenience outlets + Reverse Vending Machine load

NUMBER OF OCCUPANTS: 20

EMERGENCY POWER (yes / no, qty.): No

UTILIZATION: Monday – Friday 8-5

DATA (qty & type): N/A

IS ROOM SHARED WITH OTHERS? Other programs in building

VOICE (qty & type): N/A

RESOURCES SHARED WITH OTHERS: N/A

AUDIOVISUAL (qty & type): N/A

ADJACENCIES (internal & external): N/A

PIPED SERVICES: No

WINDOWS / NATURAL LIGHT: No

WATER / FLOOR DRAIN: No

ACOUSTICS: N/A

TEMPERATURE: Standard

SIGHTLINES: No

HUMIDITY: Standards

MIN. DOOR WIDTH & DESCRIPTION: Standard

VENTILATION: Standard

ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling:

AIR CHANGES: No

MIN. CEILING HEIGHT: 10’

HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: Recycling and vending machine links: http://reversevending.wordpress.com/tag/deposit-system-scotland/

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): FURNITURE (qty & type): EQUIPMENT (qty & type): A. Reverse Vending Machine B. Vending Machine

100

-

UNT CVAD Program Report


4.2.2 GENERAL: BUILDING / COLLEGE RECYCLING / VENDING ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

101


4.2.2 GENERAL: BUILDING / COLLEGE CUSTODIAL ROOM DETAIL SHEET

Room Detail Sheet : Custodial

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 2

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable

ASSIGNABLE SQ. FOOTAGE: 200

TYPE OF ARTIFICIAL LIGHTING: Overhead

ROOM DIMENSIONS: 20’ x 20’

POWER: Outlets for powered cleaning tools for floor wax/ vacuum

NUMBER OF OCCUPANTS: 2

EMERGENCY POWER (yes / no, qty.): No

UTILIZATION: Monday – Friday 8-5

DATA (qty & type); No

IS ROOM SHARED WITH OTHERS? Other Programs

VOICE (qty & type): No

RESOURCES SHARED WITH OTHERS:

AUDIOVISUAL (qty & type): No

ADJACENCIES (internal & external):

PIPED SERVICES: Mop Sink and Utility Sink

WINDOWS / NATURAL LIGHT: No

WATER / FLOOR DRAIN: Yes

ACOUSTICS:

TEMPERATURE: Standard

SIGHTLINES: No

HUMIDITY: Standard

MIN. DOOR WIDTH & DESCRIPTION: Standard.

VENTILATION: Standard

ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling:

AIR CHANGES: No HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES:

MIN. CEILING HEIGHT: 10’

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A A. Cleaning Cart BUILT-IN (qty & type): B. Mop Sink C. Utility Sink D. Shelves E. Counter FURNITURE (qty & type): EQUIPMENT (qty & type): F. Floor Waxing/ Buffer machines

102

-

UNT CVAD Program Report


4.2.2 GENERAL: BUILDING / COLLEGE CUSTODIAL ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

103


DEAN ADVISING SUITE Dean Advising Suite Department. Adjacencies Visual Program Space Program R.D.S. & Plan Dean Associate Dean Faculty Office Budget Officer Admin / Clerical Dean Reception Area Advising Reception Area Break Room Conference Room Mail Room Copy/Print/Storage

Notes: 1. Rooms listed in grey are common amongst all programs and therefore shown under the “general” section. 2. R.D.S. = Room Detail Sheet 3. “ * ” Existing Spaces where R.D.S. and Plan are not included


4.3 Departments Dean’s Advising Suite

The University of North Texas

The following information indicates the Communication Design program requirements. This is a highly collaborative discipline. The faculty interacts frequently with students outside of class time as well as with each other on curriculum design, research, and program planning. The classrooms, faculty offices, student workspaces, and the graduate offices should be located in close proximity. They would like to be away from other noisy disciplines. Fluidity and flexibility are key design elements for this program. Up to date technology is critical for this group. Specific departmental requirements can be found in the following Room Detail Sheets, Room Layouts, and the Space Program List.


4.3.1 DEAN ADVISING SUITE DEAN ADVISING SUITE PROGRAM ADJACENCY DIAGRAM

106

-

UNT CVAD Program Report


4.3.1 DEAN ADVISING SUITE DEAN ADVISING SUITE VISUAL PROGRAM

-

UNT CVAD Program Report

107


4.3.1 DEAN ADVISING SUITE DEAN ADVISING SUITE SPACE PROGRAM Space Name Position

Circul-ation Factor

Room Number

2013

2016

Number Assignable of Spaces S/F

Number Unit Area of Spaces

Total Area

Dean - Advising Suite Faculty Offices Dean - Robert Milnes Associate Dean - open Associate Dean - Eric Ligon Director of Development - Susan Sanders Gallery Director - Tracee Robertson Faculty Director Budget Officer - Mary Miller Dean Administrative Assistant - Gayle Cox Dean Administrative Assistant - Elyse Franks Dean Administrative Assistant - Jerry Aul Advising Manager Advisor - Lana Gee Advisor - Suzanne Coffey Advisor - Mia Dallas Advisor - Jennifer Grund Advisor - Nancy Kelly Advisor - Debbie Shifflet Advisor - Growth (Open Office/Storage/Scanning) Advisor - Growth Advisor - Growth Advising Admininstrative Assistant Support Spaces Dean Reception Area (seat 4) Advising Reception Area (seat 8) Break Room Conference Room (seat 20) Mail Room Copy/Print/Storage Room Total Spaces Assignable Square Feet Net to Gross @ 45% = Assignable SF x (1/(1-45%))= Department Gross SF

108

Art 107D/E/F Art 107B Art 111D Art 107A Art N/A Art 106 Art 107G Art 107C Art 111E N/A Art 111 Art 323A Art 111C Art 111A Art 111B Art 110 Art 109 Art 107G Art 107J N/A

1 1 1 1 1 0 1 1 1 1 0 1 1 1 1 1 1 1 1 1 0

393 174 185 123 320 120 174 229 168 101 120 493 159 134 174 134 138 138 229 110 85

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

220 200 200 130 130 130 100 60 60 60 130 130 130 130 130 130 130 130 130 130 60

220 200 200 130 130 130 100 60 60 60 130 130 130 130 130 130 130 130 130 130 60

Art 107/107 A/L Art 111 Art 107K Art 130/128AA Art 128A Art 128/107H

1 1 1 1 1 1

280 493 57 319 82 327

1 1 1 1 1 1

150 240 150 400 240 150

150 240 150 400 240 150

24 0.8181

27 5,459 4,466

3,980 3,256

9,925

7,236

-

UNT CVAD Program Report


-

UNT CVAD Program Report

109


4.3.1 DEAN ADVISING SUITE DEAN RECEPTION AREA ROOM DETAIL SHEET

Room Detail Sheet : Dean’s Advising Suite – Dean Reception Area

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1

BUILDING SYSTEM REQUIREMENTS SECURITY: Panic button; room is lockable when no staff present

ASSIGNABLE SQ. FOOTAGE: 150

TYPE OF ARTIFICIAL LIGHTING: Standard

ROOM DIMENSIONS: 10’ x 15’

POWER: 6 outlets along desk wall

NUMBER OF OCCUPANTS: 1 + 4 guests

EMERGENCY POWER (yes / no, qty.): No

UTILIZATION: Monday – Friday 8-5

DATA (qty & type): Provide Category 6A from the Telecom Room to support data outlets in this area.

IS ROOM SHARED WITH OTHERS? No RESOURCES SHARED WITH OTHERS: Dean’s Advising Suite Faculty

VOICE (qty & type): 1 phone – Provide Category 6A from the Telecom Room. AUDIOVISUAL (qty & type): N/A

ADJACENCIES (internal & external): Located in the front of the Dean/Advising Suite, separate from the Advising Reception Area

PIPED SERVICES: No

WINDOWS / NATURAL LIGHT: Yes

WATER / FLOOR DRAIN: No

ACOUSTICS: Standard

TEMPERATURE: Controllable, no need for individual control, just want to have consistency

SIGHTLINES: Visible to rest of building MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling: MIN. CEILING HEIGHT: 10’

HUMIDITY: Low to medium VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: Locate in public area with easy accessibility for students.

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): (H) mobile tables for student workers BUILT-IN (qty & type): (A) Reception desk with transaction counter FURNITURE (qty & type): (B) task chair, (C) lounge chairs, (D) coffee table, (E) Sofa, (F) Side Table, (G) 5 File Cabinets

110

-

UNT CVAD Program Report


4.3.1 DEAN ADVISING SUITE DEAN RECEPTION AREA ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

111


4.3.1 DEAN ADVISING SUITE ADVISING RECEPTION AREA ROOM DETAIL SHEET

Room Detail Sheet : Dean’s Advising Suite – Advising Reception Area

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1

BUILDING SYSTEM REQUIREMENTS SECURITY: Panic button; room is lockable when no staff present

ASSIGNABLE SQ. FOOTAGE: 240

TYPE OF ARTIFICIAL LIGHTING: Standard

ROOM DIMENSIONS: 15’ x 16’

POWER: 6 outlets along desk wall

NUMBER OF OCCUPANTS: 2 + 8 guests

EMERGENCY POWER (yes / no, qty.): No

UTILIZATION: Monday – Friday 8-5

DATA (qty & type): Provide Category 6A from the Telecom Room to support data outlets in this area.

IS ROOM SHARED WITH OTHERS? No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Located at the front of the Dean/Advising Suite with access to main circulation WINDOWS / NATURAL LIGHT: Yes ACOUSTICS: Standard

VOICE (qty & type): 1 phone – Provide Category 6A from the Telecom Room. AUDIOVISUAL (qty & type): N/A PIPED SERVICES: No WATER / FLOOR DRAIN: No

SIGHTLINES: Visible to rest of building

TEMPERATURE: Controllable, no need for individual control, just want to have consistency

MIN. DOOR WIDTH & DESCRIPTION: Standard

HUMIDITY: Low to medium

ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling:

VENTILATION: Standard

MIN. CEILING HEIGHT: 10’

SPECIAL REQUIREMENTS / NOTES: Locate in public area with easy accessibility for students.

AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): (A) Reception desk with transaction counter FURNITURE (qty & type): (B) task chair, (C) lounge chairs, (D) coffee table, (E) Sofa, (F) Side Table, (G) 5 File Cabinets

112

-

UNT CVAD Program Report


4.3.1 DEAN ADVISING SUITE ADVISING RECEPTION AREA ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

113


4.3.1 DEAN ADVISING SUITE BREAK ROOM ROOM DETAIL SHEET

Room Detail Sheet : Dean’s Advising Suite - Breakroom

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable

ASSIGNABLE SQ. FOOTAGE: 150

TYPE OF ARTIFICIAL LIGHTING: Standard

ROOM DIMENSIONS: 10’ x 12’

POWER: Convenience outlets, (1) Refrigerator, (1) microwave, (1) coffee maker

NUMBER OF OCCUPANTS: 3 - 5 UTILIZATION: Monday – Friday 8-5 IS ROOM SHARED WITH OTHERS? No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Centrally located within the Dean/Advising Suite WINDOWS / NATURAL LIGHT: No ACOUSTICS: Sound Dampening SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling: MIN. CEILING HEIGHT: 10’

EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Provide wireless network coverage in this area. VOICE (qty & type): N/A AUDIOVISUAL (qty & type): Provide CATV connectivity and backing to support large flat panel display. PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Suitable for printer AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: Used by Dean Advising Suite department only. Not shared with rest of building.

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): (A) Millwork with closed cabinet storage and counter work surface, sink FURNITURE (qty & type): (B) Table (C) Chair

114

-

UNT CVAD Program Report


4.3.1 DEAN ADVISING SUITE BREAK ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

115


4.3.1 DEAN ADVISING SUITE CONFERENCE ROOM ROOM DETAIL SHEET

Room Detail Sheet : Dean’s Advising Suite – Conference Room

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable

ASSIGNABLE SQ. FOOTAGE: 400

TYPE OF ARTIFICIAL LIGHTING: Standard

ROOM DIMENSIONS: 25’ x 16’

POWER: Outlets, Ceiling outlet for projector / screen, floor core to distribute power/data to table

NUMBER OF OCCUPANTS: 20

EMERGENCY POWER (yes / no, qty.): No

UTILIZATION: Monday – Friday 8-5 IS ROOM SHARED WITH OTHERS? No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Centrally located within the Dean/Advising Suite WINDOWS / NATURAL LIGHT: No ACOUSTICS: Ability to have confidential meetings SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling: MIN. CEILING HEIGHT: 10’

FURNITURE, FIXTURES & EQUIPMENT

DATA (qty & type): floor data outlets, data for Skype. Provide Category 6A cable from the Telecom Room. Provide network cables to support AV systems. Provide wireless network coverage. VOICE (qty & type): Polycom, or similar, device to be deployed. Provide Category 6A cable from the Telecom Room. Phone system may be deployed as VoIP and would require verification on the type of Polycom device be used. AUDIOVISUAL (qty & type): Dual wide aspect ratio projection screens with high definition projectors. Simple, intuitive control system. High quality audio system with listen assist. Digital video and audio inputs at Instructor location. Web camera and room microphone for Skype sessions. PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Standard

MOBILE (qty & type): Artwork

AIR CHANGES: No

BUILT-IN (qty & type): (C) Projection screen, (D) Credenza

HAZARDOUS MATERIALS & STORAGE METHOD: No

FURNITURE (qty & type): (A) Table, (B) Chairs

SPECIAL REQUIREMENTS / NOTES:

116

-

UNT CVAD Program Report


4.3.1 DEAN ADVISING SUITE CONFERENCE ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

117


4.3.1 DEAN ADVISING SUITE MAIL ROOM ROOM DETAIL SHEET

Room Detail Sheet : Dean’s Advising Suite – Mail Room

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable

ASSIGNABLE SQ. FOOTAGE: 240

TYPE OF ARTIFICIAL LIGHTING: Standard

ROOM DIMENSIONS: 15’ x 16’

POWER: convenience outlets, (B) Heavy Duty printer, electric stapler, electric hole punch

NUMBER OF OCCUPANTS: 2-8 UTILIZATION: Monday – Friday 8-5 IS ROOM SHARED WITH OTHERS? Other departments in building RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Centrally located within the Dean/Advising Suite WINDOWS / NATURAL LIGHT: No ACOUSTICS: Sound Dampening SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling: MIN. CEILING HEIGHT: 10’

EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Data for Skype and other equipment. Provide Category 6A from the Telecom room. VOICE (qty & type): Polycom, or similar, device to be deployed. Provide Category 6A cable from the Telecom Room. Phone system may be deployed as VoIP and would require verification on the type of Polycom device be used. AUDIOVISUAL (qty & type): N/A PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Suitable for printer AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: Printer suitable for heavy duty printing.

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): (A) Millwork with closed cabinet storage and counter work surface FURNITURE (qty & type): (B) Printer

118

-

UNT CVAD Program Report


4.3.1 DEAN ADVISING SUITE MAIL ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

119


4.3.1 DEAN ADVISING SUITE COPY / PRINT / STORAGE ROOM DETAIL SHEET

Room Detail Sheet : Dean’s Advising Suite – Copy / Print / Storage

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable

ASSIGNABLE SQ. FOOTAGE: 150

TYPE OF ARTIFICIAL LIGHTING: Standard

ROOM DIMENSIONS: 10’ x 15’

POWER: convenience outlets, (B) Heavy Duty printer, electric stapler, electric hole punch

NUMBER OF OCCUPANTS: 2-8 UTILIZATION: Monday – Friday 8-5 IS ROOM SHARED WITH OTHERS? Other departments in building RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Centrally located within the Dean/Advising Suite WINDOWS / NATURAL LIGHT: No ACOUSTICS: Sound Dampening SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling: MIN. CEILING HEIGHT: 10’

EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Data for Skype and other equipment. Provide Category 6A from the Telecom room. VOICE (qty & type): Polycom, or similar, device to be deployed. Provide Category 6A cable from the Telecom Room. Phone system may be deployed as VoIP and would require verification on the type of Polycom device be used. AUDIOVISUAL (qty & type): N/A PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Suitable for printer AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: Printer suitable for heavy duty printing.

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): (C) Mobile work tables BUILT-IN (qty & type): (A) Millwork with closed cabinet storage and counter work surface FURNITURE (qty & type): (B) Printer

120

-

UNT CVAD Program Report


4.3.1 DEAN ADVISING SUITE COPY / PRINT / STORAGE ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

121


SHARED Artist Apt Department. Adjacencies Visual Program Space Program R.D.S. & Plan Bathroom Bedroom Living Terrace

Gallery Department Adjacencies Visual Program Space Program R.D.S. & Plan Faculty Office Tech *Existing North *Existing Light well *Existing Reception Gallery /Foyer *Existing Main New CVAD Gallery *Existing Storage Room Storage Room - New Building

IT Department Adjacencies Visual Program Space Program R.D.S. & Plan Faculty Office Adjunct Office General Classroom General Access Lab General Computer Lab Main Suite Server Room Storage Equipment Storage Checkout

Notes: 1. Rooms listed in grey are common amongst all programs and therefore shown under the “general” section. 2. R.D.S. = Room Detail Sheet 3. “ * ” Existing Spaces where R.D.S. and Plan are not included

122

-

UNT CVAD Program Report


4.4 Departments SHARED SPACES

The following information indicates the Communication Design program requirements. This is a highly collaborative discipline. The faculty interacts frequently with students outside of class time as well as with each other on curriculum design, research, and program planning. The classrooms, faculty offices, student workspaces, and the graduate offices should be located in close proximity. They would like to be away from other noisy disciplines. Fluidity and flexibility are key design elements for this program. Up to date technology is critical for this group. Specific departmental requirements can be found in the following Room Detail Sheets, Room Layouts, and the Space Program List.

The University of North Texas


124

-

UNT CVAD Program Report


4.4.1 Artist Apartment

The University of North Texas

The concept for the UNT Artists Apartment was developed in the belief that artists as residents create value within the university. The goal is to help the university complete the original vision which includes a place where an artist can work and/or live within the campus experience. It provides an important opportunity for artists to live within the creative milieu of the college. The addition will add a new dimension to the CVAD program, enhancing the ambiance of the school and helping make the campus a destination for artists and students. Preferably, the space is to be located on the top floor with adjacent event/exhibit space to be used by the entire university. Detailed information is located in the following Room Detail Sheets, Room Layouts, and the Space Program List.


4.4.1 SHARED SPACES ARTIST APARTMENT PROGRAM ADJACENCY DIAGRAM

126

-

UNT CVAD Program Report


4.4.1 SHARED SPACES ARTIST APARTMENT VISUAL PROGRAM

-

UNT CVAD Program Report

127


4.4.1 SHARED SPACES ARTIST APARTMENT SPACE PROGRAM Space Name Position

Circulation Factor

Room Number

2013

2016

Number Assignable of Spaces S/F

Number Unit Area of Spaces

Total Area

Artist Apartment Apartment Bathroom Bedroom Living/Kitchen/Dining Terrace Total Spaces Assignable Square Feet Net to Gross @ 45% = Assignable SF x (1/(1-45%))= Department Gross SF

128

N/A N/A N/A N/A

0 0 0 0

0 0 0 0

0 0.8181

1 1 1 1

120 240 1500 900

120 240 1500 0

4 0 0

1,860 1,522

0

3,382

-

UNT CVAD Program Report


4.4.1 SHARED SPACES ARTIST APARTMENT FULL PLAN

NOT TO SCALE -

UNT CVAD Program Report

129


4.4.1 SHARED SPACES: ARTIST APARTMENT BATHROOM ROOM DETAIL SHEET

Room Detail Sheet : Artist Apartment Bathroom

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 120 ROOM DIMENSIONS: 10’ x 12’ NUMBER OF OCCUPANTS: 1

UTILIZATION (hours/day and general time of day): 24/7 IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Bedroom WINDOWS / NATURAL LIGHT: No ACOUSTICS: Sound dampening SIGHTLINES: Bedroom MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. MIN. CEILING HEIGHT: 10’

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard overhead fluorescent POWER (qty & type): 4 duplex GFCI outlets EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): No VOICE (qty & type): No AUDIOVISUAL (qty & type): No PIPED SERVICES: 1 sink WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Yes VENTILATION: Yes AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES:

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): 1 sink with cabinets below FURNITURE (qty & type): N/A

130

-

UNT CVAD Program Report


4.4.1 SHARED SPACES: ARTIST APARTMENT BATHROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

131


4.4.1 SHARED SPACES: ARTIST APARTMENT BEDROOM ROOM DETAIL SHEET

Room Detail Sheet : Artist Apartment Bedroom

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 240 ROOM DIMENSIONS: 12’ x 20’ NUMBER OF OCCUPANTS: 1

UTILIZATION (hours/day and general time of day): 24/7

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard overhead fluorescent POWER (qty & type): 4 duplex outlets EMERGENCY POWER (yes / no, qty.): No

IS ROOM SHARED WITH OTHERS? (list group(s)): No

DATA (qty & type): Provide Category 6A cable to support a total of two Data connections. Wireless in building is required.

RESOURCES SHARED WITH OTHERS: No

VOICE (qty & type): 1 voice outlet

ADJACENCIES (internal & external): Top of building

AUDIOVISUAL (qty & type): No

WINDOWS / NATURAL LIGHT: Yes

PIPED SERVICES: No

ACOUSTICS: No

WATER / FLOOR DRAIN: No

SIGHTLINES: Located off of living room

TEMPERATURE: Standard

MIN. DOOR WIDTH & DESCRIPTION: Standard

HUMIDITY: No

ROOM FINISHES: Standard U.N.O.

VENTILATION: No

MIN. CEILING HEIGHT: 10’

AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES:

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): 1 king size bed, 2 bedside tables, 1 dresser, 1 mirror, 1 small side chair, 1 small side table

132

-

UNT CVAD Program Report


4.4.1 SHARED SPACES: ARTIST APARTMENT BEDROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

133


4.4.1 SHARED SPACES: ARTIST APARTMENT LIVING ROOM / KITCHEN ROOM DETAIL SHEET

Room Detail Sheet : Artist Apartment Living Room / Kitchen

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 1500 ROOM DIMENSIONS: 30’ x 50’ NUMBER OF OCCUPANTS: 1

UTILIZATION (hours/day and general time of day): 24/7

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard overhead fluorescent POWER (qty & type): 5 duplex GFCI outlets EMERGENCY POWER (yes / no, qty.): No

IS ROOM SHARED WITH OTHERS? (list group(s)): No

DATA (qty & type): Category 6A cable to support Wireless connectivity in the building.

RESOURCES SHARED WITH OTHERS: No

VOICE (qty & type): No

ADJACENCIES (internal & external): Top of building

AUDIOVISUAL (qty & type): No

WINDOWS / NATURAL LIGHT: No

PIPED SERVICES: 1 Stainless steel double sink

ACOUSTICS: No

WATER / FLOOR DRAIN: No

SIGHTLINES: No

TEMPERATURE: Standard

MIN. DOOR WIDTH & DESCRIPTION: N/A

HUMIDITY: Standard

ROOM FINISHES: Standard U.N.O.

VENTILATION: 1 Stove/oven/microwave

MIN. CEILING HEIGHT: 8’

AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES:

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): 10 linear feet upper and lower cabinets FURNITURE (qty & type): N/A

134

-

UNT CVAD Program Report


4.4.1 SHARED SPACES: ARTIST APARTMENT LIVING ROOM / KITCHEN ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

135


4.4.1 SHARED SPACES: ARTIST APARTMENT TERRACE ROOM DETAIL SHEET

Room Detail Sheet : Artist Apartment Terrace

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 900 ROOM DIMENSIONS: 30’ x 30’ NUMBER OF OCCUPANTS: 1

UTILIZATION (hours/day and general time of day): 24/7 IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Top of building WINDOWS / NATURAL LIGHT: Outdoor ACOUSTICS: No SIGHTLINES: Located off of living room MIN. DOOR WIDTH & DESCRIPTION: Double doors ROOM FINISHES: Standard U.N.O. MIN. CEILING HEIGHT: 10’

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Outdoor POWER (qty & type): 2 duplex outlets EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): No VOICE (qty & type): No AUDIOVISUAL (qty & type): No PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Outdoor HUMIDITY: Outdoor VENTILATION: Outdoor AIR CHANGES: Outdoor HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES:

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): 2 outdoor lounge chairs, 1 outdoor side table

136

-

UNT CVAD Program Report


4.4.1 SHARED SPACES: ARTIST APARTMENT TERRACE ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

137



4.4.2 Gallery

The University of North Texas

The UNT Gallery reports directly to the Dean of CVAD. The responsibilities of this group include the Art in Public Places Committee as well as managing the process of selecting and purchasing the campus art collection. They are the primary source of university art publications and work closely with the Artist in Residence Program. Dedicated gallery spaces are used for art exhibitions and secure storage is crucial for storing the collections. The existing Art Building Gallery Spaces are to remain. The New CVAD Building will house the new Gallery Space with exterior access for exhibits and general public admission. Additional program information is located in the following Room Detail Sheets, Room Layouts and the Space Program List.


4.4.2 SHARED SPACES GALLERY PROGRAM ADJACENCY DIAGRAM

140

-

UNT CVAD Program Report


4.4.2 SHARED SPACES GALLERY VISUAL PROGRAM

-

UNT CVAD Program Report

141


4.4.2 SHARED SPACES GALLERY SPACE PROGRAM Space Name Position

Circulation Factor

Room Number

2013

2016

Number Assignable of Spaces S/F

Number Unit Area of Spaces

Total Area

Gallery Faculty Offices Assistant Director - Victoria De Cuir Assistant Director Manager of Programming - Michael Little Faculty Growth - Public Relations Faculty Growth - Graduate Assistants (3 share 1 desk)

Art 221 Art 221 Art 221 N/A N/A

1 1 1 0 1

457 0 0 0 0

1 1 1 1 1

130 130 130 130 35

130 130 130 130 35

Galleries Existing North Gallery Existing Lightwell Gallery Existing Reception Gallery / Foyer Existing Main Gallery New CVAD Gallery

Art 101 Art 120 Art 126 Art 100 N/A

1 1 1 1 0

1056 1040 752 2291 0

1 1 1 1 1

1056 1040 752 2291 5000

1056 1040 752 2291 5000

1 0

503 0

1 1

503 4500

503 4500

Support Spaces Storage Room Storage Room - New Building Total Spaces Assignable Square Feet Net to Gross @ 45% = Assignable SF x (1/(1-45%))= Department Gross SF

142

Art 113/113A N/A

9 0.8181

12 6,099 4,990

15,697 12,842

11,089

28,539

-

UNT CVAD Program Report


-

UNT CVAD Program Report

143


4.4.2 SHARED SPACES: GALLERY EXISTING NORTH ROOM DETAIL SHEET

Room Detail Sheet : Gallery Existing North

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 1056 ROOM DIMENSIONS: NUMBER OF OCCUPANTS: 100+/UTILIZATION (hours/day and general time of day): 8-5, M-F, Occasionally after hours and on weekends

IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): No WINDOWS / NATURAL LIGHT: No ACOUSTICS: No

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): No LED POWER (qty & type): 110v x 1 outlet on each wall EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Provide Category 6A cable from the Telecom room to support five computer connections. Provide wireless network coverage this area. Ensure all wireless devices are located in a ceiling or wall enclosure. Provide Power over Ethernet for wireless devices. Provide Category 6A cable from the Telecom room to support AV systems. VOICE (qty & type): Provide Category 6A cable to support one voice connection in the Gallery.

MIN. DOOR WIDTH & DESCRIPTION: 6’ Double doors

AUDIOVISUAL (qty & type): Permanent loudspeakers and support equipment for ambient music capabilities. Request for configuring localized sound. Request to conceal all cables. Possible separate Video Art Room with raised floor and concealed small adjacent equipment room for computers, Blu-Ray players etc.

ROOM FINISHES: Gallery white

PIPED SERVICES: No

MIN. CEILING HEIGHT: 15’

WATER / FLOOR DRAIN: No

SIGHTLINES: No

FURNITURE, FIXTURES & EQUIPMENT

TEMPERATURE: Standard

MOBILE (qty & type): N/A

HUMIDITY: Standard

BUILT-IN (qty & type): N/A

VENTILATION: Standard

FURNITURE (qty & type): N/A

AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: No overhead sprinkler or water lines.

144

-

UNT CVAD Program Report


4.4.2 SHARED SPACES: GALLERY EXISTING LIGHTWELL ROOM DETAIL SHEET

Room Detail Sheet : Gallery Existing Lightwell

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 1040 ROOM DIMENSIONS: NUMBER OF OCCUPANTS: 100+/-

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): No LED POWER (qty & type): Existing EMERGENCY POWER (yes / no, qty.): No

UTILIZATION (hours/day and general time of day): 8-5, M-F, Weekends

DATA (qty & type): Existing

IS ROOM SHARED WITH OTHERS? (list group(s)): No

VOICE (qty & type): Existing

RESOURCES SHARED WITH OTHERS: No

AUDIOVISUAL (qty & type): No

ADJACENCIES (internal & external): Located in existing Art Building

PIPED SERVICES: No

WINDOWS / NATURAL LIGHT: No

WATER / FLOOR DRAIN: No TEMPERATURE: Standard

ACOUSTICS: No

HUMIDITY: Standard

SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Open area ROOM FINISHES: Gallery white

VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No

MIN. CEILING HEIGHT: Standard

FURNITURE, FIXTURES & EQUIPMENT

SPECIAL REQUIREMENTS / NOTES: No overhead sprinkler or water lines.

MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): N/A

-

UNT CVAD Program Report

145


4.4.2 SHARED SPACES: GALLERY EXISTING RECEPTION / FOYER ROOM DETAIL SHEET

Room Detail Sheet : Gallery Existing Reception/Foyer

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 752 ROOM DIMENSIONS: NUMBER OF OCCUPANTS:

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): No LED POWER (qty & type): 110v x 1 outlet on each wall EMERGENCY POWER (yes / no, qty.): No

UTILIZATION (hours/day and general time of day): 8-5, M-F, Occasionally after hours and on weekends

DATA (qty & type): No

IS ROOM SHARED WITH OTHERS? (list group(s)): No

VOICE (qty & type): No

RESOURCES SHARED WITH OTHERS: No

AUDIOVISUAL (qty & type): No

ADJACENCIES (internal & external): Main Gallery

PIPED SERVICES: No

WINDOWS / NATURAL LIGHT: No

WATER / FLOOR DRAIN: No

ACOUSTICS: No

TEMPERATURE: Standard

SIGHTLINES: No

HUMIDITY: Standard

MIN. DOOR WIDTH & DESCRIPTION: 6’ Double doors

VENTILATION: Standard

ROOM FINISHES: Gallery white

AIR CHANGES: Standard

MIN. CEILING HEIGHT: 15’

HAZARDOUS MATERIALS & STORAGE METHOD: No

FURNITURE, FIXTURES & EQUIPMENT

SPECIAL REQUIREMENTS / NOTES:

MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): N/A

146

-

UNT CVAD Program Report


4.4.2 SHARED SPACES: GALLERY EXISTING MAIN ROOM DETAIL SHEET

Room Detail Sheet : Gallery Existing Main

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 2291 ROOM DIMENSIONS: NUMBER OF OCCUPANTS: 100+/UTILIZATION (hours/day and general time of day): 8-5, M-F, Occasionally after hours and on weekends

IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Located in existing Art Building WINDOWS / NATURAL LIGHT: No ACOUSTICS: No SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: 6’ Double doors ROOM FINISHES: Gallery white

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): No LED POWER (qty & type): 110v x 1 outlet on each wall EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Provide Category 6A cable from the Telecom room to support five computer connections. Provide wireless network coverage this area. Ensure all wireless devices are located in a ceiling or wall enclosure. Provide Power over Ethernet for wireless devices. Provide Category 6A cable from the Telecom room to support AV systems. VOICE (qty & type): Provide Category 6A cable to support one voice connection in the Gallery. AUDIOVISUAL (qty & type): Permanent loudspeakers and support equipment for ambient music capabilities. Request for configuring localized sound. Request to conceal all cables. Possible separate Video Art Room with raised floor and concealed small adjacent equipment room for computers, Blu-Ray players etc. PIPED SERVICES: No WATER / FLOOR DRAIN: No

MIN. CEILING HEIGHT: Standard

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): N/A

TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: No overhead sprinkler or water lines.

-

UNT CVAD Program Report

147


4.4.2 SHARED SPACES: GALLERY NEW CVAD ROOM DETAIL SHEET

Room Detail Sheet : Gallery New CVAD

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 5000 ROOM DIMENSIONS: 50’ x 100’ NUMBER OF OCCUPANTS: 100+/UTILIZATION (hours/day and general time of day): 8-5, M-F, Occasionally after hours and on weekends

IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): First floor, Exterior access Food Preparation. Loading dock WINDOWS / NATURAL LIGHT: No ACOUSTICS: Yes SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: 6’ Double doors and 10’ high. ROOM FINISHES: Gallery white Floor: sealed stained concrete flooring Base: Walls: Ceiling:

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable doors and Security Cameras TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): No LED POWER (qty & type): 110v x 1 Outlet on each wall, power for security cameras. EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Provide Category 6A cable from the Telecom room to support five computer connections. Provide wireless network coverage this area. Ensure all wireless devices are located in a ceiling or wall enclosure. Provide Power over Ethernet for wireless devices. Provide Category 6A cable from the Telecom room to support AV systems. VOICE (qty & type): Provide Category 6A cable to support one voice connection in the Gallery. AUDIOVISUAL (qty & type): Permanent loudspeakers and support equipment for ambient music capabilities. Request for configuring localized sound. Request to conceal all cables. Possible separate Video Art Room with raised floor and concealed small adjacent equipment room for computers, Blu-Ray players etc. PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Standard

MIN. CEILING HEIGHT: Standard

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type):

A. Museum Bench

148

VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: • No overhead sprinkler or water lines. • Needs dedicated storage space. • somehow have the gallery be a separate from the building • exterior gallery space desired

-

UNT CVAD Program Report


4.4.2 SHARED SPACES: GALLERY NEW CVAD ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

149


4.4.2 SHARED SPACES: GALLERY NEW CVAD STORAGE ROOM DETAIL SHEET

Room Detail Sheet : Gallery New CVAD Storage

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 4500 ROOM DIMENSIONS: 45’ x 100’ NUMBER OF OCCUPANTS: 1-2 UTILIZATION (hours/day and general time of day): Variable, including 9 am - 5 pm, 5 days per/week

BUILDING SYSTEM REQUIREMENTS SECURITY: Alarm, swipe TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Overhead fluorescent with UV protection POWER (qty & type): Electric, network throughout spaces EMERGENCY POWER (yes / no, qty.): Standard

RESOURCES SHARED WITH OTHERS: No

DATA (qty & type): 2 Data outlets. Provide Category 6A cable from the Telecom room to support two data connections. Provide wireless network coverage this area. Ensure all wireless devices are located in a ceiling or wall enclosure. Provide Power over Ethernet for wireless devices.

ADJACENCIES (internal & external): External access to loading dock with lift gate

VOICE (qty & type): Provide Category 6A cable from the Telecom room to support one voice connection in the Gallery Storage.

WINDOWS / NATURAL LIGHT: No natural light or windows

AUDIOVISUAL (qty & type): No

ACOUSTICS: No

PIPED SERVICES: Overhead dry pipes

SIGHTLINES: No

WATER / FLOOR DRAIN: Sink in storage area to clean paint materials

MIN. DOOR WIDTH & DESCRIPTION: Double doors with no middle post or threshold; 10’h x 10’w; sealed with dust protection

TEMPERATURE: 68-72 F

IS ROOM SHARED WITH OTHERS? (list group(s)): No

ROOM FINISHES: Standard U.N.O. Floor: Sealed concrete Base: Walls: Reinforced sheetrock Ceiling: Sealed concrete

HUMIDITY: 50%, +/-5 VENTILATION: Normal AIR CHANGES: Dedicated HVAC units in storage and preparation areas

MIN. CEILING HEIGHT: 15’

HAZARDOUS MATERIALS & STORAGE METHOD: No

FURNITURE, FIXTURES & EQUIPMENT

SPECIAL REQUIREMENTS / NOTES: HVAC and security should be dedicated and contained without shared spaces. No overhead sprinkler or water lines.

BUILT-IN (qty & type):

Each gallery should have its own dedicated storage space (within gallery storage?)

MOBILE (qty & type):

FURNITURE (qty & type): A. Desk, chair – registrar

B. Exhibit Furniture / Equipment C. Computers D. Carts E. Folding Tables F. Shelving / Storage for Artwork.

150

-

UNT CVAD Program Report


4.4.2 SHARED SPACES: GALLERY NEW CVAD STORAGE ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

151



4.4.3 The University of North Texas

IT The following information pertains to the IT Department. The main spaces should be located in the New CVAD Building to take advantage of the new infrastructure. The department manages the IT infrastructure for the college as well as several classrooms that are used by multiple departments. Security as well as interconnectivity between all buildings is very important. Additional program information is located in the following Room Detail Sheets, Room Layouts and the Space Program List.


4.4.3 SHARED SPACES IT PROGRAM ADJACENCY DIAGRAM

154

-

UNT CVAD Program Report


4.4.3 SHARED SPACES IT VISUAL PROGRAM

-

UNT CVAD Program Report

155


4.4.3 SHARED SPACES IT SPACE PROGRAM Space Name Position

Circulation Factor

Room Number

2013

2016

Number Assignable of Spaces S/F

Number Unit Area of Spaces

Total Area

IT Faculty Offices IT Manager - Michael Baggett Web Manager - Kacey Close Operations Manager - Craig Berry Lab/Classroom Manager Server Monitor Faculty Growth - IT Facility Research Specialist

Art 228A Art 231 Art 228

1 1 1

176 640 300

N/A N/A

0 0

Classrooms General Classroom

Art 226

Labs General Access Lab General Computer Lab Support Spaces Main Suite Server Room (in Main Suite) Storage Room (in Main Suite) Equipment Storage Check-Out Room (in Gen. Access Lab) Total Spaces Assignable Square Feet Net to Gross @ 45% = Assignable SF x (1/(1-45%))= Department Gross SF

156

0 0

1 1 1 1 1 1

130 130 130 130 65 130

130 130 130 130 65 130

1

773

1

2000

2000

Art 232 Art 231

1 1

1759 640

1 4

3750 1750

3750 7000

Art 233 Art 228B Art 262 Art 230

1 1 1 1

782 235 81 84

1 1 1 1

300 300 300 300

300 300 300 300

10 0.8181

16 5,470 4,475

14,665 11,997

9,945

26,662

-

UNT CVAD Program Report


-

UNT CVAD Program Report

157


4.4.3 SHARED SPACES: IT GENERAL CLASSROOM ROOM DETAIL SHEET

Room Detail Sheet: IT General Classroom

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 2000 ROOM DIMENSIONS: 40’ x 50’ NUMBER OF OCCUPANTS: 50 UTILIZATION (hours/day and general time of day): M-F 7:30am-12am; Saturday Various

IS ROOM SHARED WITH OTHERS? (list groups): Three for Studio Arts, one for Design, one for AEAH RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): CVAD IT–General Access Lab; CVAD IT–Department Photography; New Media; Design WINDOWS / NATURAL LIGHT: No ACOUSTICS: Requires quiet for students to work SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Double Doors ROOM FINISHES: Standard U.N.O. Floor: Carpet Base: Walls: Suitable for pin up work Ceiling:

BUILDING SYSTEM REQUIREMENTS SECURITY: Requires security alarm(s), controlled access; card swipe indicating who accesses the room. TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Overhead fluorescent POWER (qty & type): 7 circuits. 2x4 outlets and 4x2 outlets to serve between 50 computers and associated equipment. EMERGENCY POWER (yes / no, qty.): UPS DATA (qty & type): Provide Category 6A cable from the nearest Telecom Room to support 50 workstation data network connections. Provide Category 6A cable to support Wireless connectivity and Audio Visual. Dedicated Ethernet for each computer (including instructor station). VOICE (qty & type): Provide one voice cable to support an alarm. AUDIOVISUAL (qty & type): Displays for student artwork and college and university announcements; Dual wide aspect ratio projection screens with high definition projectors. Simple, intuitive control system. High quality audio system with listen assist. Digital video and audio inputs at Instructor location. Web camera and room microphone for Skype sessions. PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Normal for building but this area will generate more heat than most due to number of computers HUMIDITY: Standard

MIN. CEILING HEIGHT: Standard

VENTILATION: yes

FURNITURE, FIXTURES & EQUIPMENT

AIR CHANGES: Standard

MOBILE (qty & type): A. Computer Laptop and Tablet carts

HAZARDOUS MATERIALS & STORAGE METHOD: No

BUILT-IN (qty & type): B. Cabinets for materials and counters

SPECIAL REQUIREMENTS / NOTES: Requires extra data, power and climate control. Computers (monitors in classroom provided by UNT).

FURNITURE (qty & type): C. 22-28 Desks D. Displays for student artwork E. Lectern and stool.

158

-

UNT CVAD Program Report


4.4.3 SHARED SPACES: IT GENERAL CLASSROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

159


4.4.3 SHARED SPACES: IT GENERAL ACCESS LAB ROOM DETAIL SHEET

Room Detail Sheet: IT General Access Lab

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 2359 (2500) ROOM DIMENSIONS: 30’ x 80’ (50’ x 75’) NUMBER OF OCCUPANTS: 60-65 UTILIZATION (hours/day and general time of day): 24 / 7

IS ROOM SHARED WITH OTHERS? (list groups): CVAD IT–Computer Classrooms; CVAD IT–Department; Design; New Media; Photography RESOURCES SHARED WITH OTHERS: Lab Equipment Storage and Checkout; Printers ADJACENCIES (internal & external): CVAD IT–Computer Classrooms; CVAD IT–Department; Photography; New Media; Design WINDOWS / NATURAL LIGHT: Windows providing natural light ACOUSTICS: Requires quiet for students to work SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Double Doors

BUILDING SYSTEM REQUIREMENTS SECURITY: Requires security alarm; controlled access card swipe TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Overhead fluorescent POWER (qty & type): power for 65 computers and associated equipment EMERGENCY POWER (yes / no, qty.): Yes DATA (qty & type): 4 8x2 wall jacks; 5 ceiling jacks. Provide Category 6A cable from the Telecom room to each workstation location in the Lab. Provide wireless network coverage this area. Ensure all wireless devices are located in a ceiling or wall enclosure. Provide Power over Ethernet for wireless devices. Provide Category 6A cable from the Telecom room to support AV systems. VOICE (qty & type): Provide Category 6A cable from the Telecom room to support two phones and one alarm connection. Verify with Security system the type of alarm connection required. AUDIOVISUAL (qty & type): Flat panel displays for student artwork and college and university announcements PIPED SERVICES: Standard WATER / FLOOR DRAIN: Standard TEMPERATURE: This area will generate more heat than most due to number of computers. HUMIDITY: Dry

ROOM FINISHES: Standard U.N.O. Floor: Carpet Base: Walls: Suitable for hanging artwork Ceiling:

VENTILATION: Yes

MIN. CEILING HEIGHT: Standard

HAZARDOUS MATERIALS & STORAGE METHOD: No

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): A. Laptop and tablet carts BUILT-IN (qty & type): B. Check-in station for three employees, C. Cabinets and D. Shelves for materials and equipment, and E. Student lockers FURNITURE (qty & type): F.60 Desks G. Display for artwork H. Printer I. Semi-private consultation table with chairs for Lab Manager, faculty staff and students J. 3 Counter-height chairs/stools. K. Larger computer monitors are ideal (24” screens currently in the general access labs) L. Flatbed scanner M. Plotter (various sizes)

160

AIR CHANGES: High

SPECIAL REQUIREMENTS / NOTES: • Requires extra data, power and climate control. Lab attendant desk is currently curved to allow visual access to all of room. Include a standing height transaction counter at this desk for student access. Locate desk near room entrance. Printers are to be close to the lab attendants. Lab Attendants check student in and out. Allow for storage under counter for attendants personal items.

-

UNT CVAD Program Report


4.4.3 SHARED SPACES: IT GENERAL ACCESS LAB ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

161


4.4.3 SHARED SPACES: IT GENERAL COMPUTER LAB ROOM DETAIL SHEET

Room Detail Sheet: IT General Computer Lab

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 4 ASSIGNABLE SQ. FOOTAGE: 1525 (1750) ROOM DIMENSIONS: (35’ x 50’) x 4 = 7000 NUMBER OF OCCUPANTS: 25 UTILIZATION (hours/day and general time of day): M-F 8-5; Saturday Various; Sunday Various IS ROOM SHARED WITH OTHERS? (list groups): CVAD IT-General Access Lab; CVAD IT-Computer Classrooms RESOURCES SHARED WITH OTHERS: Shared IT Storage Space; Server Room. ADJACENCIES (internal & external): CVAD IT-General Access Lab; CVAD IT-Computer Classrooms; DRC

WINDOWS / NATURAL LIGHT: Window for Main Suite area preferred. ACOUSTICS: No SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Double Doors. ROOM FINISHES: Standard U.N.O. Floor: Carpet Base: Walls: Ceiling: MIN. CEILING HEIGHT: Standard

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): Computer Laptop and A.Tablet carts BUILT-IN (qty & type): Cabinets

BUILDING SYSTEM REQUIREMENTS SECURITY: Requires security alarm TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Overhead fluorescent POWER (qty & type): See attached EMERGENCY POWER (yes / no, qty.): Yes. UPS 3hrs storage DATA (qty & type): Provide Category 6A cables to support all network connections in these spaces (see attached quantities). Provide wireless network coverage this area. Ensure all wireless devices are located in a ceiling or wall enclosure. Provide Power over Ethernet for wireless devices. Provide Category 6A cable to from the Telecom room to support AV systems. VOICE (qty & type): 5 Phones plus 1 for alarm. Provide one Category 6A cable from the Telecom room to support “alarm” function. Verify security requirements for this connection. AUDIOVISUAL (qty & type): Displays for student artwork and college and university announcements; Dual wide aspect ratio projection screens with high definition projectors. Simple, intuitive control system. High quality audio system with listen assist. Digital video and audio inputs at Instructor location. Web camera and room microphone for Skype sessions. PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Server room requires independently controlled temperature management HUMIDITY: Server room requires independently controlled humidity management VENTILATION: No AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: Requires extra data, power and climate control

FURNITURE (qty & type): B.Desks, C.cabinets, D.work benches, E.meeting table F.Wall Display

162

-

UNT CVAD Program Report


4.4.3 SHARED SPACES: IT GENERAL COMPUTER LAB ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

163


4.4.3 SHARED SPACES: IT MAIN SUITE ROOM DETAIL SHEET

Room Detail Sheet: IT Main Suite

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 360 (300) ROOM DIMENSIONS: 12’ x 30’ (15’ x 20’) NUMBER OF OCCUPANTS: 3-5 plus customers (students and faculty) UTILIZATION (hours/day and general time of day): M-F 8-5; Saturday Various; Sunday Various IS ROOM SHARED WITH OTHERS? (list groups): No RESOURCES SHARED WITH OTHERS: IT Suite ADJACENCIES (internal & external): Direct access from Operation Manager’s Office and direct access to IT shared Storage; General Access Lab, Computer Classrooms, Departmental Offices; Dean’s Suite WINDOWS / NATURAL LIGHT: Windows providing natural light ACOUSTICS: Standard

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable. Controlled access TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Overhead fluorescent POWER (qty & type): 3 circuits (20 amp); 6x2 outlets standard. 1 standard for wall monitor at above standard meeting height EMERGENCY POWER (yes / no, qty.): Yes DATA (qty & type): 6x4 wall jacks; 1 data at above standard meeting height. Provide Category 6A cables from the Telecom room to each office. Provide at least four data cable per office. Provide wireless network coverage this area. Ensure all wireless devices are located in a ceiling or wall enclosure. Provide Power over Ethernet for wireless devices. Provide Category 6A cables from the Telecom room to support AV systems. The server room will require fiber and copper connectivity between servers and storage devices. Fiber backbone from the Server room to each Telecom room is required. VOICE (qty & type): Provide Category 6A cable from the Telecom room to support five phone connections and one alarm connection. Verify with Security requirements for type of connection required.

SIGHTLINES: No

AUDIOVISUAL (qty & type): Wall mounted flat panel display in main suite

MIN. DOOR WIDTH & DESCRIPTION: Standard

PIPED SERVICES: No

ROOM FINISHES: Standard U.N.O. Floor: Carpet Base: Walls: Ceiling:

WATER / FLOOR DRAIN: No TEMPERATURE: Standard

MIN. CEILING HEIGHT: Standard

VENTILATION: Standard

FURNITURE, FIXTURES & EQUIPMENT

AIR CHANGES: Standard

MOBILE (qty & type): A. Laptop and tablet carts BUILT-IN (qty & type): B. Cabinets - Reception counter/ service desk FURNITURE (qty & type): C. 3-5 work benches and chairs behind a counter D. Wall for monitor display

164

HUMIDITY: Standard

HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: 1475 for IT suite doesn’t include future position for Faculty/Staff research. Need addtl 130sf for office

-

UNT CVAD Program Report


4.4.3 SHARED SPACES: IT MAIN SUITE ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

165


4.4.3 SHARED SPACES: IT SERVER ROOM ROOM DETAIL SHEET

Room Detail Sheet: IT Sever Room

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 300 ROOM DIMENSIONS: 15’ x 20’ NUMBER OF OCCUPANTS: 3-5 plus customers (students and faculty) UTILIZATION (hours/day and general time of day): M-F 8-5; Saturday Various; Sunday Various IS ROOM SHARED WITH OTHERS? (list groups): No RESOURCES SHARED WITH OTHERS: IT Suite ADJACENCIES (internal & external): Access from IT Manager Ofifice and Operations manager Office; General Access lab, Computer Classrooms. WINDOWS / NATURAL LIGHT: No ACOUSTICS: Standard SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: Prefer raised access flooring Base: Walls: Ceiling:

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable. Controlled access TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Overhead fluorescent POWER (qty & type): 6 circuits (30 amp); 1 Circuit (20 amp); 2x2 Wall 30 amp outlets EMERGENCY POWER (yes / no, qty.): Generator for UPS, Server, Cooling units DATA (qty & type): Provide fiber optic cable, 50-micron and single mode, between server cabinets and network cabinets. Connect all Telecom Rooms with fiber back to the IT Server Room, at minimum provide 12-strand between each TR and Server Room. Provide Category 6A cable to eight (8) locations in the room. Provide Category 6A cable to support Audio Visual systems. VOICE (qty & type): Provide one (1) voice cable to support alarm functions in the space. Coordinate with security to determine exact procedures for connectivity. AUDIOVISUAL (qty & type): Wall mounted flat panel digital display PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Independently controlled; 24/7 air HUMIDITY: Independently controlled humidity management VENTILATION: Standard for server room AIR CHANGES: Standard for server room

MIN. CEILING HEIGHT: Standard

HAZARDOUS MATERIALS & STORAGE METHOD: No

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): A. Racks (qty?) (Includes Design Research Center’s Server Equipment)

SPECIAL REQUIREMENTS / NOTES: None

BUILT-IN (qty & type): B. Plywood backer board FURNITURE (qty & type): No

166

-

UNT CVAD Program Report


4.4.3 SHARED SPACES: IT SERVER ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

167


4.4.3 SHARED SPACES: IT STORAGE ROOM DETAIL SHEET

Room Detail Sheet: IT Storage

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 300 ROOM DIMENSIONS: 15’ x 20’ NUMBER OF OCCUPANTS: 3-5 plus customers (students and faculty) UTILIZATION (hours/day and general time of day): M-F 8-5; Saturday Various; Sunday Various IS ROOM SHARED WITH OTHERS? (list groups): No RESOURCES SHARED WITH OTHERS: IT Suite ADJACENCIES (internal & external): Direct access from Operation Manager’s Office and direct access to IT shared Storage; General Access Lab, Computer Classrooms, Departmental Offices; Dean’s Suite

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable. Controlled access TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Overhead fluorescent POWER (qty & type): 4 circuits (30 amp); 4x4 Standard outlets EMERGENCY POWER (yes / no, qty.): Yes DATA (qty & type): Provide Category 6A cable from the nearest Telecom Room to support eight (8) network connections. Provide Category 6A cable to support Wireless connectivity and Audio Visual systems VOICE (qty & type): Provide Category 6A cable from the nearest Telecom Room to support one (1) voice connection. AUDIOVISUAL (qty & type): Wall mounted flat panel digital display PIPED SERVICES: No WATER / FLOOR DRAIN: No

WINDOWS / NATURAL LIGHT: Windows providing natural light

TEMPERATURE: Standard

ACOUSTICS: Standard

HUMIDITY: Standard

SIGHTLINES: No

VENTILATION: Standard

MIN. DOOR WIDTH & DESCRIPTION: Standard

AIR CHANGES: Standard

ROOM FINISHES: Standard U.N.O. Floor: Carpet Base: Walls: Ceiling:

HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: Equipment for faculty and staff; allow space within room for staging.

MIN. CEILING HEIGHT: Standard

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): A. Laptop and tablet carts BUILT-IN (qty & type): B. Heavy-duty adjustable shelves 18” deep and running the full length of the wall to serve new computers and computer equipment FURNITURE (qty & type): No

168

-

UNT CVAD Program Report


4.4.3 SHARED SPACES: IT STORAGE ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

169


4.4.3 SHARED SPACES: IT EQUIPMENT STORAGE CHECKOUT ROOM ROOM DETAIL SHEET

Room Detail Sheet: IT Equipment Storage Checkout Room

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 300 ROOM DIMENSIONS: 15’ x 20’ NUMBER OF OCCUPANTS: 0 UTILIZATION (hours/day and general time of day): M-F 7:30am-12am; Saturday Various; Sunday Various

BUILDING SYSTEM REQUIREMENTS SECURITY: Requires security alarm; controlled access card swipe TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Overhead fluorescent POWER (qty & type): 4 circuits (30 amp); 4x4 outlets EMERGENCY POWER (yes / no, qty.): Yes

IS ROOM SHARED WITH OTHERS? (list groups): General Access Lab

DATA (qty & type): Provide Category 6A cable from the nearest Telecom Room to support data network connectivity. Provide four (4) locations with eight (8) data connections, provide five (5) data connections mounted into the ceiling.

RESOURCES SHARED WITH OTHERS: General Access Lab

VOICE (qty & type): No

ADJACENCIES (internal & external): Direct access to General Access Lab, Lab Classroom, and Manager’s Office.

AUDIOVISUAL (qty & type): No PIPED SERVICES: No

WINDOWS / NATURAL LIGHT: Windows providing natural light

WATER / FLOOR DRAIN: No

ACOUSTICS: Standard

TEMPERATURE: Standard

SIGHTLINES: No

HUMIDITY: Standard

MIN. DOOR WIDTH & DESCRIPTION: Standard

VENTILATION: Standard

ROOM FINISHES: Standard U.N.O. Floor: Carpet Base: Walls: Ceiling:

AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: None

MIN. CEILING HEIGHT: Standard

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): No BUILT-IN (qty & type): A. Heavy-duty adjustable shelves, min 18” depth to house printing and other lab-related supplies as well as backup computer equipment. FURNITURE (qty & type): No

170

-

UNT CVAD Program Report


4.4.3 SHARED SPACES: IT EQUIPMENT STORAGE CHECKOUT ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

171


AEAH AEAH: CAMSCI / NTIEVA Department. Chair Suite Department. Adjacencies Visual Program Space Program R.D.S.: / Plans: Department Chair / Director Faculty Office Admin / Clerical Reception Area Conference Room Storage/Copy/Print Room

AEAH Department Adjacencies Visual Program Space Program R.D.S. & Plan Faculty Office Adjunct Office Graduate Bullpen Outdoor Kiln Yard Multi-Purpose Seminar/Class Art Ed. Children and Art Class Art Ed. Individual Restroom Art Ed. Workroom Storage Room Print Room

Notes: 1. Rooms listed in grey are common amongst all programs and therefore shown under the “general” section. 2. R.D.S. = Room Detail Sheet 3. “ * ” Existing Spaces where R.D.S. and Plan are not included


4.5 Departments AEAH

The University of North Texas

The following areas make up the Department of Art Education and Art History (AEAH) and the two institutes, the North Texas Institute for Educators on the Visual Arts (NTIEVA) as well as the Contemporary Arab and Muslim Culture and Studies Institute (CAMCSI). The philosophies that shape this area include supporting the chair and faculty of Art Education and Art History department, field faculty, student and visitors. This discipline is not typically collaborative with other disciplines. Specific departmental requirements can be found in the following Room Detail Sheets, Room Layouts and Space Program List.


174

-

UNT CVAD Program Report


4.5.1 AEAH : CAMSCI / NTIEVA DEPARTMENT CHAIR SUITE

The University of North Texas

University Department Chairs are the primary spokespersons for department faculty, staff, and students. At the same time, institutions of higher education have an increasing reliance upon department chairs to implement and carry out campus policy and to communicate the mission of the institution for the central administration. The department suites need to be centrally located within each department and easily accessible by the students. The Chair Suite shall contain the Chair, Chair Administrative Assistant, Graduate Coordinators and Instructional Support. The suite shall also contain a reception area, small conference room and support requirements. Additional information can be found on the following Room Detail Sheets, Room Layouts, and the Space Program List.


4.5.1 AEAH AEAH DEPARTMENT CHAIR SUITE PROGRAM ADJACENCY DIAGRAM

176

-

UNT CVAD Program Report


4.5.1 AEAH AEAH DEPARTMENT CHAIR SUITE VISUAL PROGRAM

-

UNT CVAD Program Report

177


4.5.1 AEAH AEAH DEPARTMENT CHAIR SUITE SPACE PROGRAM Space Name

2013

2016

Circulation Room Factor Number

Number of Spaces

Department Chair Office Department Chairperson - Cindy Mohr Administrative Assistant - Open

Art 237 Art 237A

1 1

209 181

1 1

170 65

170 0

Support Spaces Chair Reception Area Chair Conference Room Chair Storage/Copy/Print

Art 237A N/A Art 270

1 0 1

0 0 40

1 1 1

200 200 200

200 200 200

Position

Assignable S/F

Number of Spaces

Unit Area

Total Area

Department Chair -Design

Total Spaces Assignable Square Feet Net to Gross @ 45% = Assignable SF x (1/(1-45%))= Department Gross SF

178

4 0.8181

5 430 352

770 630

782

1,400

-

UNT CVAD Program Report


K-Herc-Lichas-Canova -

UNT CVAD Program Report

179


4.5.1 AEAH: DEPARTMENT CHAIR SUITE RECEPTION ROOM DETAIL SHEET

Room Detail Sheet : Departmental Chair Suite Reception

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 200 ROOM DIMENSIONS: 10’ x 20’ NUMBER OF OCCUPANTS: 1

UTILIZATION (hours/day and general time of day): 8-5 M-F IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Chair Administrative Assistant WINDOWS / NATURAL LIGHT: No ACOUSTICS: No SIGHTLINES: Chair conference room MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling: MIN. CEILING HEIGHT: 10’

BUILDING SYSTEM REQUIREMENTS SECURITY: Keyed with Department Chair Offices TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard overhead fluorescent POWER (qty & type): 120v x 5 outlets EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Provide Category 6A cable from the nearest Telecom Room to support two network connections. Provide Category 6A cable to support Wireless connectivity. VOICE (qty & type): Provide Category 6A cable from the nearest Telecom Room to support one voice connections. AUDIOVISUAL (qty & type): No PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES:

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): 1 Sofa, 2 guest chairs, 1 coffee table, 2 side tables

180

-

UNT CVAD Program Report


4.5.1 AEAH: DEPARTMENT CHAIR SUITE RECEPTION ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

181


4.5.1 AEAH: DEPARTMENT CHAIR SUITE CONFERENCE ROOM ROOM DETAIL SHEET

Room Detail Sheet : Department Chair Suite - Conference Room

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 200 ROOM DIMENSIONS: 10’ x 20’ NUMBER OF OCCUPANTS: 6 UTILIZATION (hours/day and general time of day): 8-5 M - F IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Reception WINDOWS / NATURAL LIGHT: No

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard overhead fluorescent POWER (qty & type): Standard outlets spaced according to code. EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Provide Category 6A cable to support three network connections. Provide Category 6A cable to support wireless connectivity. Provide Category 6A cable to support Audio Visual systems. VOICE (qty & type): Provide Category 6A cable to support three phone connections. Each phone shall have Voice Mail capability

SIGHTLINES: No

AUDIOVISUAL (qty & type): Wide aspect ratio HD display(s). Simple, intuitive control system. High quality audio system with listen assist. Digital video and audio inputs. Web camera and room microphone for Skype sessions.

MIN. DOOR WIDTH & DESCRIPTION: Standard

PIPED SERVICES: No

ROOM FINISHES: Standard U.N.O. Floors: Base: Walls: Ceiling:

WATER / FLOOR DRAIN: No

MIN. CEILING HEIGHT: 10’

VENTILATION: Standard

FURNITURE, FIXTURES & EQUIPMENT

AIR CHANGES: Standard

ACOUSTICS: Privacy

MOBILE (qty & type): N/A

TEMPERATURE: Standard HUMIDITY: Standard

HAZARDOUS MATERIALS & STORAGE METHOD: No

BUILT-IN (qty & type): N/A FURNITURE (qty & type): 1 table to seat 6, 6 conference chairs, 1 credenza

182

SPECIAL REQUIREMENTS / NOTES:

-

UNT CVAD Program Report


4.5.1 AEAH: DEPARTMENT CHAIR SUITE CONFERENCE ROOM ROOM PLAN

-

UNT CVAD Program Report

183


4.5.1 AEAH: DEPARTMENT CHAIR SUITE STORAGE / COPY / PRINT ROOM ROOM DETAIL SHEET

Room Detail Sheet : Department Chair Suite Storage / Copy / Print Room

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 200

BUILDING SYSTEM REQUIREMENTS SECURITY: Keyed with Department Office and key faculty access separately.

ROOM DIMENSIONS: 10’ x 20’

TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard overhead fluorescent

NUMBER OF OCCUPANTS: 3

POWER (qty & type): 120v x 4 outlets

UTILIZATION (hours/day and general time of day): 8-5 M-F

EMERGENCY POWER (yes / no, qty.): No

IS ROOM SHARED WITH OTHERS? (list group(s)): No

DATA (qty & type): No

RESOURCES SHARED WITH OTHERS: No

VOICE (qty & type): No

ADJACENCIES (internal & external): In department location, adjacent to Administrative Assistant

AUDIOVISUAL (qty & type): No

WINDOWS / NATURAL LIGHT: No ACOUSTICS: No SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling: MIN. CEILING HEIGHT: 10’

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): 3 rolling seat carts BUILT-IN (qty & type): 8LF of base and upper cabinets for copy / print functions. Flexible shelving to accommodate supplies and long range storage FURNITURE (qty & type): Flexible shelving to accommodate supplies and long range storage

184

PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: We currently have two small closets that are our only storage. We have no long-range storage capabilities. We have carts and other types of storage distributed around the department in classrooms and offices. We must also provide storage for ALL work produced in the ID classes for the two years prior to our CIDA site visit. Must be located near the exhibition locations. In the past we have had to store in other buildings with resulting damage to some of the work. In addition to the door from the suite, add an additional door from the hallway for faculty access.

-

UNT CVAD Program Report


4.5.1 AEAH: DEPARTMENT CHAIR SUITE STORAGE / COPY / PRINT ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

185



4.5.2 AEAH

The University of North Texas

The following areas make up the Department of Art Education and Art History (AEAH) and the two institutes, the North Texas Institute for Educators on the Visual Arts (NTIEVA) as well as the Contemporary Arab and Muslim Culture and Studies Institute (CAMCSI). The philosophies that shape this area include supporting the chair and faculty of Art Education and Art History department, field faculty, student and visitors. This discipline is not typically collaborative with other disciplines. Specific departmental requirements can be found in the following Room Detail Sheets, Room Layouts and Space Program List.


4.5.2 AEAH AEAH PROGRAM ADJACENCY DIAGRAM

188

-

UNT CVAD Program Report


4.5.2 AEAH AEAH VISUAL PROGRAM

-

UNT CVAD Program Report

189


4.5.2 AEAH AEAH SPACE PROGRAM Space Name Position

Circulation Factor

Room Number

2013

2016

Number Assignable of Spaces S/F

Number Unit Area of Spaces

Total Area

AEAH NTIEVA CAMCSI Faculty Offices Art Education Professor - Joni Acuff Art Education Professor - Terry Barrett Art Education Professor - Laura Evans Art Education Professor -Nadine Kalin Art Education Professor -Amy Kraehe Art Education Professor -Adetty Perez de Miles Art Education/History Growth - Adjunct Art Education/History Growth - Professor Art History Professor - Mickey Abel Art History Professor - Kelly Donahue Wallace Art History Professor - Kurt Rahmlow Art History Professor - Lisa Owen Art History Professor - Jennifer Way

N/A Art 216 Art 253 Art 217 Art 322B Art 224E N/A N/A Art 213 Art 215 Art 229 Art 210 Art 212

1 1 1 1 1 1 0 0 1 1 1 1 1

211 272 176 118 184 190 0 0 143 178 178 87 178

1 1 1 1 1 1 1 1 1 1 1 1 1

130 130 130 130 130 130 65 130 130 130 130 130 130

130 130 130 130 130 130 65 130 130 130 130 130 130

Studio Graduate Bullpen

Art 225

1

476

5

300

1500

N/A

0

0

1

120

0

Art 251 Art 322

1 1

549 1557

4 1

1200 2500

4800 2500

Art 251C Art 322B Art 322C

0 1 1 1

0 341 190 378

1 1 1 1

80 500 200 150

80 500 200 150

Shop Art Education Outdoor Kiln Classrooms Multi-Purpose Seminar/Classroom (seat 25) Art Education Children and Art Classroom (seat 60) Support Spaces Art Education Individual Restroom Art Education Workroom Storage Room Print Room Total Spaces Assignable Square Feet Net to Gross @ 45% = Assignable SF x (1/(1-45%))= Department Gross SF

190

17 0.8181

28 5,406 4,423

11,355 9,290

9,829

20,645

-

UNT CVAD Program Report


Islamic_Art_2012 UNT -

UNT CVAD Program Report

191


4.5.2 AEAH: AEAH GRADUATE BULLPEN ROOM DETAIL SHEET

Room Detail Sheet : AEAH Graduate Bullpen SPACE REQUIREMENTS

BUILDING SYSTEM REQUIREMENTS

ROOM QUANTITY: 5

SECURITY: Standard

ASSIGNABLE SQ. FOOTAGE: 1000 X 5 = 5000

TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard overhead fluorescent

ROOM DIMENSIONS: 25’ X 40’ NUMBER OF OCCUPANTS: 15 each (total 75) UTILIZATION (hours/day and general time of day): 24/7 IS ROOM SHARED WITH OTHERS? (list group(s)):

POWER (qty & type): 120v x 75 outlets EMERGENCY POWER (yes / no, qty.): DATA (qty & type): Provide Category 6A cable to support Wireless connectivity in this space. VOICE (qty & type):

RESOURCES SHARED WITH OTHERS: ADJACENCIES (internal & external): Seminar Classroom (art History) and Multipurpose / Seminar WINDOWS / NATURAL LIGHT: Yes ACOUSTICS: Sound dampening SIGHTLINES: MIN. DOOR WIDTH & DESCRIPTION: Standard’ ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling: MIN. CEILING HEIGHT: 10’

AUDIOVISUAL (qty & type): Wall mounted flat panel display(s) with digital information display capabilities. PIPED SERVICES: WATER / FLOOR DRAIN: TEMPERATURE: Standard HUMIDITY: Dry VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES:

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): A. 15 8’ x 3’ height adjustable work table B. 15 Chairs C. 1 Meeting Table B. 2 Meeting Chairs

192

-

UNT CVAD Program Report


4.5.2 AEAH: AEAH GRADUATE BULLPEN ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

193


4.5.2 AEAH: AEAH OUTDOOR KILN YARD ROOM DETAIL SHEET

Room Detail Sheet : AEAH Outdoor Kiln Yard (Art Education)

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 120 ROOM DIMENSIONS: 10’ x 12’ NUMBER OF OCCUPANTS: 3 UTILIZATION (hours/day and general time of day): 8am – 5pm, M-F, Saturday School

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Exterior light POWER (qty & type): GFI suitable for outdoor weather for the electric kiln EMERGENCY POWER (yes / no, qty.): No

IS ROOM SHARED WITH OTHERS? (list group(s)): No

DATA (qty & type): None. Consideration for outside Wireless capabilities.

RESOURCES SHARED WITH OTHERS: No

VOICE (qty & type): No

ADJACENCIES (internal & external): Art Education Children’s Classroom or Workroom

AUDIOVISUAL (qty & type): No

WINDOWS / NATURAL LIGHT: Exterior ACOUSTICS: N/A SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Standard gate door, or building door to Art Education classroom ROOM FINISHES: Standard U.N.O. Floor: Concrete pad Base: Walls: Ceiling:

PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: (Outdoor space) HUMIDITY: N/A VENTILATION: Standard if enclosed AIR CHANGES: Standard if enclosed HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES:

MIN. CEILING HEIGHT: 9’ – Exterior roof/overhang

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): A. Electric Kiln for ceramics

194

-

UNT CVAD Program Report


4.5.2 AEAH: AEAH OUTDOOR KILN YARD ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

195


4.5.2 AEAH: AEAH MULTI-PURPOSE SEMINAR / CLASSROOM ROOM DETAIL SHEET

Room Detail Sheet : AEAH Multi-Purpose Seminar/Classroom

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 4

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable

ASSIGNABLE SQ. FOOTAGE: 1500 x 4 = 6000

TYPE OF ARTIFICIAL LIGHTING: Overhead

ROOM DIMENSIONS: 30’ x 50’ each

POWER: convenience outlets, floor cores for guests to power up laptops, along front of room

NUMBER OF OCCUPANTS: 25 seats each x 4 ( 100 seats) UTILIZATION: Monday – Friday 8-5, After hours

EMERGENCY POWER (yes / no, qty.): No

IS ROOM SHARED WITH OTHERS? No

DATA (qty & type); floor cores for guests to power up laptops, along front of room

RESOURCES SHARED WITH OTHERS: No

VOICE (qty & type): No

ADJACENCIES (internal & external): AEAH department, AEAH Breakroom

AUDIOVISUAL (qty & type): Projection screen, speakers

WINDOWS / NATURAL LIGHT: No

PIPED SERVICES: No

ACOUSTICS: Standard

WATER / FLOOR DRAIN: No

SIGHTLINES: No

TEMPERATURE: Standard

MIN. DOOR WIDTH & DESCRIPTION: Standard

HUMIDITY: Standard

ROOM FINISHES: Standard U.N.O. Floor: Standard Base: rubber Walls: paint Ceiling: tile

VENTILATION: Suitable for printer

MIN. CEILING HEIGHT: 10’

SPECIAL REQUIREMENTS / NOTES: Used when have special events, symposiums, guest speakers, etc. Serve food and drinks at events

AIR CHANGES: No HAZARDOUS MATERIALS & STORAGE METHOD: No

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): Projection screen FURNITURE (qty & type): (D) 30x60 desk, (C) task chair, (A) training tables to seat 100, (B) 100 stackable chairs

196

-

UNT CVAD Program Report


4.5.2 AEAH: AEAH MULTI-PURPOSE SEMINAR / CLASSROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

197


4.5.2 AEAH: AEAH CHILDREN AND ART CLASSROOM ( ART EDUCATION) ROOM DETAIL SHEET

Room Detail Sheet : AEAH Children and Art Classroom (Art Education)

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 2500 ROOM DIMENSIONS: 50’ x 50’

NUMBER OF OCCUPANTS: 60 Seats (26 K-12 Students, 35 adult students, helpers and teaching aids)

BUILDING SYSTEM REQUIREMENTS SECURITY: Controlled card access TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard and dimmable down lights. POWER (qty & type): 9 quaduplex, power for appliances, equipment on each wall for convenience, and for charging cabinet EMERGENCY POWER (yes / no, qty.): No

UTILIZATION (hours/day and general time of day): 8am – 5pm, M-F, Saturday School

DATA (qty & type): For electronic displays at workroom computers

IS ROOM SHARED WITH OTHERS? (list group(s)): No

VOICE (qty & type): No

RESOURCES SHARED WITH OTHERS: No

AUDIOVISUAL (qty & type): 1. Power Module within cabinetry 2. Interior Display 3. Exterior Display 4. Dual Projector Screens 6’ wide, located centrally 5. Speakers for Skype, hearing impaired occupants, and activities engaging music

ADJACENCIES (internal & external): Ground Floor Public Gallery, Individual Restroom, Storage, Outdoor Kiln Yard, Exterior drop off and pick up for children (with shade) WINDOWS / NATURAL LIGHT: Natural Light, Windows also serve for exterior display ACOUSTICS: for Audio/Visual SIGHTLINES: Garden / Community Access MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: Non-slip Concrete or resilient Base: Walls: Ceiling: MIN. CEILING HEIGHT: 9’

PIPED SERVICES: No WATER / FLOOR DRAIN: 1. 1 sink with clay trap 2. 1 sink with retractable step for elementary aged students 3. (2) sinks with a minimum of 4 drains and faucets 4. I separate clay trap 5. Floor drain (optional) 6. Hot Water TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No

198

SPECIAL REQUIREMENTS / NOTES: -Safe edges on all corners. -Flexibility: furniture to allow for configurations of up to 25 students (shared by adult students). -External display/gallery. -Tables arranged in U shape so that adults can sit opposite of children -Potentially 30 wireless tablets -Paper towel/soap dispense by sinks -No divisible fixed partitions in the middle of the classroom (as currently exists in Art# 322) -No poster storage required -Cubbie storage could be a display wall on other side with hooks for smocks -Storage at eye level or below -Ample shallow shelves – can be racks with a solid shelf or pull-out tray in a cabinet -

UNT CVAD Program Report


4.5.2 AEAH: AEAH CHILDREN AND ART CLASSROOM ( ART EDUCATION) ROOM DETAIL SHEET CONTINUED

Room Detail Sheet : AEAH Children and Art Classroom (Art Education) (Page 2)

University of North Texas College of Visual Arts + Design FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A A. 4’ x 6’ Smart Board (Mobil with power)

BUILT-IN (qty & type): N/A B. Ample storage cabinets with charging cabinet for laptops. 30% closed/ 70% open for shallow tubs. Need to see what is in tubs. A portion of storage can be in storage room or workroom. C. Cubbies – storage for children’s coats and rack for backpacks and adult students D. Wall length Magnetic White Board E. Exterior display cabinets (12”d or sim to have 2 video display screens for rotating artwork and announcements) F. Interior display – can be on the backside of exterior displays – doors/walls clad in tackable, magnetic/writable surface FURNITURE (qty & type): G. (30) (15) 3’d x 6’l x 30”h Tables with locking casters with durable worksurface H. (5) 30” high stools I. 60 Chairs (armless, molded plastic or similar)

J. Drying rack with wire – 36” x 24” with 30 shelves K. Shelving for 3D artwork L. Butcher paper on racks M. Teaching island (sim. To art 322) with angled mirror overhead for instructing and technology access to aux computer N. (6) Blenders (Six blenders currently in AEAH Workroom)

NOT TO SCALE -

UNT CVAD Program Report

199


4.5.2 AEAH: AEAH CHILDREN AND ART CLASSROOM ( ART EDUCATION) ROOM PLAN

NOT TO SCALE 200

-

UNT CVAD Program Report


-

UNT CVAD Program Report

201


4.5.2 AEAH: AEAH INDIVIDUAL RESTROOM ROOM DETAIL SHEET

Room Detail Sheet : AEAH Individual Restroom

University of North Texas SPACE REQUIREMENTS ROOM QUANTITY: 1 College of Visual Arts + Design ASSIGNABLE SQ. FOOTAGE: 80 ROOM DIMENSIONS: 8’ x 10’ NUMBER OF OCCUPANTS: 3

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard POWER (qty & type): Standard EMERGENCY POWER (yes / no, qty.): No

UTILIZATION (hours/day and general time of day): 8-5, M-F

DATA (qty & type): No

IS ROOM SHARED WITH OTHERS? (list group(s)): No

VOICE (qty & type): No

RESOURCES SHARED WITH OTHERS: No

AUDIOVISUAL (qty & type): No

ADJACENCIES (internal & external): Studios

PIPED SERVICES: No

WINDOWS / NATURAL LIGHT: Yes

WATER / FLOOR DRAIN: Water Closet and Sink with Floor Drain and cleanable trap.

ACOUSTICS: Soundproofing for toilet flush SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: 3’ ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling: MIN. CEILING HEIGHT: Standard

TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Exhaust and Vent AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES:

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): Cabinet for sink and storage below Paper towel dispenser / air hand dryer Mirror above Sink Trash can Feminine disposal Needle disposal Seat cover Diaper changing Station Sink soap dispenser toilet paper dispenser Urinal? Fulll length mirror by lounge

202

FURNITURE (qty & type): A. 2 lounge chair B. Table EQUIPMENT (qty & type):

-

UNT CVAD Program Report


4.5.2 AEAH: AEAH INDIVIDUAL RESTROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

203


4.5.2 AEAH: AEAH WORKROOM (ART EDUCATION) ROOM DETAIL SHEET

Room Detail Sheet : AEAH Workroom (Art Education)

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design

BUILDING SYSTEM REQUIREMENTS

ROOM QUANTITY: 1

SECURITY: Controlled Access

ASSIGNABLE SQ. FOOTAGE: 500

TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard

ROOM DIMENSIONS: 20’ x 25’ NUMBER OF OCCUPANTS: 15 UTILIZATION (hours/day and general time of day): 8-5, M-F, Saturday School

POWER (qty & type): 6 x 120v washer/dryer special outlets EMERGENCY POWER (yes / no, qty.): No

IS ROOM SHARED WITH OTHERS? (list group(s)): No

DATA (qty & type): Provide Category 6 cable to support Wireless connectivity in the space. Provide data connections to support Audio Visual systems.

RESOURCES SHARED WITH OTHERS: No

VOICE (qty & type): No

ADJACENCIES (internal & external): Direct Access to Art Education classroom

AUDIOVISUAL (qty & type): Technology access to AV and computer

WINDOWS / NATURAL LIGHT: Yes ACOUSTICS: Sound attenuation in walls for washer/dryer SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling: MIN. CEILING HEIGHT: Standard

PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Standard and special ventilation AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: Washer and dryer used to clean smocks and rags

FURNITURE, FIXTURES & EQUIPMENT

MOBILE (qty & type): A. 18” -24”d Mobile Storage (to roll into classroom as needed) BUILT-IN (qty & type): N/A B. Shelving C. Cabinetry / Work Island with a self-healing work surface and open storage below (for paper cutter, ect.) FURNITURE (qty & type): D. 1 36” x 24” drying rack with wire and 30 shelves E. 6 blenders F. Paper Cutter (at work island) G. 2 Workstations (for curriculum prep with computer, shared printer and supply file pedestal) H. Printer I. 5 Stools (at work island) J. Washer K. Dryer L. 4 Refrigerated drawers for art supplies

204

-

UNT CVAD Program Report


4.5.2 AEAH: AEAH WORKROOM (ART EDUCATION) ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

205


4.5.2 AEAH: AEAH STORAGE ROOM ROOM DETAIL SHEET

Room Detail Sheet : AEAH Storage Room

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1

6 19 2013

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable

ASSIGNABLE SQ. FOOTAGE: 200

TYPE OF ARTIFICIAL LIGHTING: Overhead

ROOM DIMENSIONS: 10’ x 20’

POWER: convenience outlets

NUMBER OF OCCUPANTS: 1

EMERGENCY POWER (yes / no, qty.): No

UTILIZATION: Monday – Friday 8-5

DATA (qty & type); No

IS ROOM SHARED WITH OTHERS? No

VOICE (qty & type): No

RESOURCES SHARED WITH OTHERS: AEAH Faculty

AUDIOVISUAL (qty & type): No

ADJACENCIES (internal & external): AEAH Reception, AEAH Chair

PIPED SERVICES: No N/A

WINDOWS / NATURAL LIGHT: No ACOUSTICS: No SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: Standard Base: rubber Walls: paint Ceiling: tile MIN. CEILING HEIGHT: 10’

WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: Houses student files that must keep for extended time, and office supplies. Current storage room size is adequate but layout does not allow for storage on 2 walls

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): (A) maximize lockable 5-high file cabinets, (B) worktable

206

-

UNT CVAD Program Report


4.5.2 AEAH: AEAH STORAGE ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

207


4.5.2 AEAH: AEAH PRINTER ROOM ROOM DETAIL SHEET

Room Detail Sheet : AEAH Printer Room

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable

ASSIGNABLE SQ. FOOTAGE: 150

TYPE OF ARTIFICIAL LIGHTING: Overhead

ROOM DIMENSIONS: 10’ x 15’

POWER: convenience outlets, (B) Heavy Duty printer, electric stapler, electric hole punch

NUMBER OF OCCUPANTS: 1 UTILIZATION: Monday – Friday 8-5 IS ROOM SHARED WITH OTHERS? Other departments in building

EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Data for Skype and other equipment. Provide Category 6A from the Telecom room.

ADJACENCIES (internal & external): Near AEAH department

VOICE (qty & type): Polycom, or similar, device to be deployed. Provide Category 6A cable from the Telecom Room. Phone system may be deployed as VoIP and would require verification on the type of Polycom device be used.

WINDOWS / NATURAL LIGHT: No

AUDIOVISUAL (qty & type): N/A

ACOUSTICS: No

PIPED SERVICES: No

SIGHTLINES: No

WATER / FLOOR DRAIN: No

MIN. DOOR WIDTH & DESCRIPTION: Standard

TEMPERATURE: Standard

ROOM FINISHES: Standard U.N.O. Floor: Standard Base: rubber Walls: paint Ceiling: tile

HUMIDITY: Standard

MIN. CEILING HEIGHT: 10’

HAZARDOUS MATERIALS & STORAGE METHOD: No

RESOURCES SHARED WITH OTHERS: No

VENTILATION: Suitable for printer AIR CHANGES: Standard

SPECIAL REQUIREMENTS / NOTES: Printer suitable for heavy duty printing.

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): (A) Millwork with closed cabinet storage and counter work surface FURNITURE (qty & type): Standard

208

-

UNT CVAD Program Report


4.5.2 AEAH: AEAH PRINTER ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

209


DESIGN Design Department. Chair Suite: Department Adjacencies Visual Program Space Program R.D.S. & Plan Department Chair / Director Tech Reception Area Conference Room Storage/Copy/Print Room

Communication Design Department Adjacencies Visual Program Space Program R.D.S. & Plan Faculty Offices Class/Lab MFA Seminar Special Class/Lab/Studio Grad Studio Render Farm Spray Room Clean Up/Darkroom Critique Room Resource Room Storage Room

Fashion Department Adjacencies Visual Program Space Program R.D.S. & Plan Faculty Office Design Studio/Lecture Special Class Lab/Lecture Knitting Studio CAD Studio Room Graduate Studio Critique Room Sewing Production Workroom Storage Room

4.6


Fibers Department Adjacencies Visual Program Space Program R.D.S. & Plan Faculty Office Admin / Clerical Critique/Lecture Room Grad Studios Weaving 1 Studio Advanced Weaving Studio Computerized Weaving Studio Digital Printing Studio Knitting/Sewing Off-Loom Weaving Paper making Studio Screen Print/Surface Design Surface Design Studio Washout Booth Darkroom Exposure Unit Room Chemical Room Warping Room Resource Room Advanced Weaving Supply Closet

Departments DESIGN

Industrial Design Department Adjacencies Visual Program Space Program R.D.S. & Plan Faculty Office Class/Lab/Studio Graduate Studio Wood Shop Shop Critique Room Storage Room

Interior Design Department Adjacencies Visual Program Space Program R.D.S. & Plan Faculty Office Tech Class/Lab/Studio Graduate Studio Critique/Lighting Lab Storage Room Copy Room Resource Room

Notes: 1. Rooms listed in grey are common amongst all programs and therefore shown under the “general” section. 2. R.D.S. = Room Detail Sheet 3. “ * ” Existing Spaces where R.D.S. and Plan are not included

The University of North Texas


212

-

UNT CVAD Program Report


4.6.1 DESIGN DEPARTMENT CHAIR SUITE

The University of North Texas

University Department Chairs are the primary spokespersons for department faculty, staff, and students. At the same time, institutions of higher education have an increasing reliance upon department chairs to implement and carry out campus policy and to communicate the mission of the institution for the central administration. The department suites need to be centrally located within each department and easily accessible by the students. The Chair Suite shall contain the Chair, Chair Administrative Assistant, Graduate Coordinators and Instructional Support. The suite shall also contain a reception area, small conference room and support requirements. Additional information can be found on the following Room Detail Sheets, Room Layouts, and the Space Program List.


4.6.1 DESIGN DESIGN DEPARTMENT CHAIR SUITE PROGRAM ADJACENCY DIAGRAM

214

-

UNT CVAD Program Report


4.6.1 DESIGN DESIGN DEPARTMENT CHAIR SUITE VISUAL PROGRAM

-

UNT CVAD Program Report

215


4.6.1 DESIGN DESIGN DEPARTMENT CHAIR SUITE SPACE PROGRAM Space Name

2013

2016

Circulation Room Factor Number

Number of Spaces

Department Chair Office Department Chairperson - Cindy Mohr Administrative Assistant - Open

Art 237 Art 237A

1 1

209 181

1 1

170 65

170 0

Support Spaces Chair Reception Area Chair Conference Room Chair Storage/Copy/Print

Art 237A N/A Art 270

1 0 1

0 0 40

1 1 1

200 200 200

200 200 200

Position

Assignable S/F

Number of Spaces

Unit Area

Total Area

Department Chair -Design

Total Spaces Assignable Square Feet Net to Gross @ 45% = Assignable SF x (1/(1-45%))= Department Gross SF

216

4 0.8181

5 430 352

770 630

782

1,400

-

UNT CVAD Program Report


Top 10 Office trends

-

UNT CVAD Program Report

217


4.6.1 DESIGN: DESIGN DEPARTMENT CHAIR SUITE RECEPTION ROOM DETAIL SHEET

Room Detail Sheet : Departmental Chair Suite Reception

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 200 ROOM DIMENSIONS: 10’ x 20’ NUMBER OF OCCUPANTS: 1

UTILIZATION (hours/day and general time of day): 8-5 M-F IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Chair Administrative Assistant WINDOWS / NATURAL LIGHT: No ACOUSTICS: No SIGHTLINES: Chair conference room MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling: MIN. CEILING HEIGHT: 10’

BUILDING SYSTEM REQUIREMENTS SECURITY: Keyed with Department Chair Offices TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard overhead fluorescent POWER (qty & type): 120v x 5 outlets EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Provide Category 6A cable from the nearest Telecom Room to support two network connections. Provide Category 6A cable to support Wireless connectivity. VOICE (qty & type): Provide Category 6A cable from the nearest Telecom Room to support one voice connections. AUDIOVISUAL (qty & type): No PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES:

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): 1 Sofa, 2 guest chairs, 1 coffee table, 2 side tables

218

-

UNT CVAD Program Report


4.6.1 DESIGN: DESIGN DEPARTMENT CHAIR SUITE RECEPTION ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

219


4.6.1 DESIGN: DESIGN DEPARTMENT CHAIR SUITE CONFERENCE ROOM ROOM DETAIL SHEET

Room Detail Sheet : Department Chair Suite Conference Room

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 225 ROOM DIMENSIONS: 15’ x 15’ NUMBER OF OCCUPANTS: 6 UTILIZATION (hours/day and general time of day): 8-5 M - F IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard overhead fluorescent POWER (qty & type): Standard outlets spaced according to code. EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): 3 Computer lines VOICE (qty & type): 3 Voice mail systems

ADJACENCIES (internal & external): Reception

AUDIOVISUAL (qty & type): 1 Overhead projection system and screen

WINDOWS / NATURAL LIGHT: No

PIPED SERVICES: No

ACOUSTICS: Privacy

WATER / FLOOR DRAIN: No

SIGHTLINES: No

TEMPERATURE: Standard

MIN. DOOR WIDTH & DESCRIPTION: Standard

HUMIDITY: Standard

ROOM FINISHES: Standard U.N.O. Floors: Base: Walls: Ceiling:

VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No

MIN. CEILING HEIGHT: 10’ SPECIAL REQUIREMENTS / NOTES:

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): 1 table to seat 6, 6 conference chairs, 1 credenza

220

-

UNT CVAD Program Report


4.6.1 DESIGN: DESIGN DEPARTMENT CHAIR SUITE CONFERENCE ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

221


4.6.1 DESIGN: DESIGN DEPARTMENT CHAIR SUITE STORAGE / COPY / PRINT ROOM ROOM DETAIL SHEET

Room Detail Sheet : Department Chair Suite Storage / Copy / Print Room

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 200

BUILDING SYSTEM REQUIREMENTS SECURITY: Keyed with Department Office and key faculty access separately.

ROOM DIMENSIONS: 10’ x 20’

TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard overhead fluorescent

NUMBER OF OCCUPANTS: 3

POWER (qty & type): 120v x 4 outlets

UTILIZATION (hours/day and general time of day): 8-5 M-F

EMERGENCY POWER (yes / no, qty.): No

IS ROOM SHARED WITH OTHERS? (list group(s)): No

DATA (qty & type): No

RESOURCES SHARED WITH OTHERS: No

VOICE (qty & type): No

ADJACENCIES (internal & external): In department location, adjacent to Administrative Assistant

AUDIOVISUAL (qty & type): No

WINDOWS / NATURAL LIGHT: No ACOUSTICS: No SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling: MIN. CEILING HEIGHT: 10’

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): 3 rolling seat carts BUILT-IN (qty & type): 8LF of base and upper cabinets for copy / print functions. Flexible shelving to accommodate supplies and long range storage FURNITURE (qty & type): Flexible shelving to accommodate supplies and long range storage

222

PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: We currently have two small closets that are our only storage. We have no long-range storage capabilities. We have carts and other types of storage distributed around the department in classrooms and offices. We must also provide storage for ALL work produced in the ID classes for the two years prior to our CIDA site visit. Must be located near the exhibition locations. In the past we have had to store in other buildings with resulting damage to some of the work. In addition to the door from the suite, add an additional door from the hallway for faculty access.

-

UNT CVAD Program Report


4.6.1 DESIGN: DESIGN DEPARTMENT CHAIR SUITE STORAGE / COPY / PRINT ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

223



4.6.2 Communication Design

The University of North Texas

The following information indicates the Communication Design program requirements. This is a highly collaborative discipline. The faculty interacts frequently with students outside of class time as well as with each other on curriculum design, research, and program planning. The classrooms, faculty offices, student workspaces, and the graduate offices should be located in close proximity. They would like to be away from other noisy disciplines. Fluidity and flexibility are key design elements for this program. Up to date technology is critical for this group. Specific departmental requirements can be found in the following Room Detail Sheets, Room Layouts, and the Space Program List.


4.6.2 DESIGN COMMUNICATION DESIGN PROGRAM ADJACENCY DIAGRAM

226

-

UNT CVAD Program Report


4.6.2 DESIGN COMMUNICATION DESIGN VISUAL PROGRAM

-

UNT CVAD Program Report

227


4.6.2 DESIGN COMMUNICATION DESIGN SPACE PROGRAM Space Name Position

Circulation Factor

Room Number

2013

2016

Number Assignable of Spaces S/F

Number Unit Area of Spaces

Total Area

Communication Design Faculty Offices Professor - Alex Egner Professor - Karen Dorff Professor - Michael Gibson Professor - Keith Owens Professor - Michele O'Rourke Kaplan Professor - Clinton Carlson Professor - Open Faculty Growth - Professor Classrooms Class/Lab MFA Seminar Special Class/Lab/Studio Studios Graduate Studio Student Workroom (and classroom) Student Workroom (and classroom) Labs Render Farm Render Farm Support Spaces Spray Room Clean Up / Darkroom Critique Room Student Library Resource Room Storage Room Storage Room Total Spaces Assignable Square Feet Net to Gross @ 45% = Assignable SF x (1/(1-45%))= Department Gross SF

228

Art 239D Art 209 Curry 311 Art 208 Art 239B Art 239A Art 239C N/A

1 1 1 1 1 1 1 0

130 178 182 178 178 128 130 0

1 1 1 1 1 1 1 5

130 130 130 130 130 130 130 130

130 130 130 130 130 130 130 650

Art 238 N/A Art 241

1 0 1

722 0 1054

6 2 1

2200 1500 1500

13,200 3000 1500

N/A Art 234 Art 234A

0 1 1

0 608 602

12 0 0

300 0 0

3600 0 0

Curry 315 Curry 303B

1 1

658 23

1 1

0 1200

0 1200

Art 341 Art 252A Art 252B Art 252 251C Art 319A Art 320A

1 1 1 1 1 1 1

68 0 0 110 135 195 195

1 1 1 0 1 0 1

80 150 900 0 625 0 400

80 150 900 0 625 0 400

20 0.8181

40 5,474 4,478

26,215 21,446

9,952

47,661

-

UNT CVAD Program Report


Whitney Smith -

UNT CVAD Program Report

229


4.6.2 DESIGN: COMMUNICATION DESIGN CLASS / LAB ROOM DETAIL SHEET

Room Detail Sheet : Communication Design – Class / Lab

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 6

ASSIGNABLE SQ. FOOTAGE: 1250 2200 x 6 = 13200 ROOM DIMENSIONS: 40’ X 55’ NUMBER OF OCCUPANTS: 20-24 (20 students, 1 instructor, 3 grad students observing)

BUILDING SYSTEM REQUIREMENTS SECURITY: 24hour swipe card access TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Adjustability, dimmable fixtures with track lighting along side walls above pinup space

UTILIZATION (hours/day and general time of day): Monday – Friday 8-6, may be used by students after hours

POWER (qty & type): Floor cores for training tables, power at front of room for instructor computer and projection screen

IS ROOM SHARED WITH OTHERS? (list group(s)): Communications Design Association

EMERGENCY POWER (yes / no, qty.): No

RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Com Design Student Workroom, Resource Room, Storage Room, Faculty Offices, Design Chair Suite, and other design programs. WINDOWS / NATURAL LIGHT: Yes, with control for demo/presentations

DATA (qty & type): Data in floor cores and at front of room for instructor computer. Provide Category 6A cables from the Telecom room. Provide wireless network coverage this area. Ensure all wireless devices are located in a ceiling or wall enclosure. Provide Power over Ethernet for wireless devices. VOICE (qty & type): No

SIGHTLINES: No

AUDIOVISUAL (qty & type): Dual wide aspect ratio projection screens with high definition projectors. Simple, intuitive control system. High quality audio system with listen assist. Digital video and audio inputs at Instructor location. Web camera and room microphone for Skype sessions.

MIN. DOOR WIDTH & DESCRIPTION: 42”

PIPED SERVICES: Sink

ROOM FINISHES: Standard U.N.O. Floor: Concrete Base: Walls: Paint, pinup material on side walls, marker board on front wall Ceiling:

WATER / FLOOR DRAIN: No

ACOUSTICS: Standard

FURNITURE, FIXTURES & EQUIPMENT

MOBILE (qty & type): A. 2’d x 6’l Training tables with tilt able top for drawing but flat for computer work to seat 22 total with power at work surface. B. 22 ergonomic chairs, C. 2 Mobile marker boards in lieu of permanent wall mounted boards BUILT-IN (qty & type): Sink with counterpace and lockable cabinet storage that does not interfere with critique walls; maybe front of the room. FURNITURE (qty & type): D. 1 Task stool, E. 1 Analog Clocks on wall; F. 1 30x60 standing height desk at front of room, G. 1 Projection screen, H. Whiteboards along front of room; same wall as projection screen I. 4 Flat files to store work J. Instructor Table K. Instructor chair

230

TEMPERATURE: Controllable, no need for individual control, just want to have consistency HUMIDITY: Low to medium VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: • Standardize the classrooms to suit needs of any subjects/sections; flexibility to rearrange setup each day. • Space for students to pinup work on walls then stand back far enough to accurately review and critique. • Sink used for cleanup when using messy materials. • Training tables need to be wide enough for each student to lay out work and laptop. • Instructor computer setup at back of room so can view students. Instructor uses laptop. Need setup at desk. • 8’ Clear between perimeter walls and desks.

-

UNT CVAD Program Report


4.6.2 DESIGN: COMMUNICATION DESIGN CLASS / LAB ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

231


4.6.2 DESIGN: COMMUNICATION DESIGN CLASS / LAB ROOM DETAIL SHEET

Room Detail Sheet: Communication Design MFA Seminar Room SPACE REQUIREMENTS ROOM QUANTITY: 2 ASSIGNABLE SQ. FOOTAGE: 1500 x 2 = 3000 ROOM DIMENSIONS: 30’ x 50’ NUMBER OF OCCUPANTS: 50

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc): POWER (qty & type): It is very important to have multiple power outlets located in ceiling, floor and walls.

UTILIZATION (hours/day and general time of day): During weekdays classes can be from 8am to 8pm –Students must have access to the room during weekdays late hours and weekends. Occasional students exhibitions may take place here as well.

EMERGENCY POWER (yes / no, qty.): No

IS ROOM SHARED WITH OTHERS? (list group(s)):

VOICE (qty & type): No

RESOURCES SHARED WITH OTHERS: No

WINDOWS / NATURAL LIGHT: No

AUDIOVISUAL (qty & type): Dual wide aspect ratio projection screens with high definition projectors. Simple, intuitive control system. High quality audio system with listen assist. Digital video and audio inputs at Instructor location. Web camera and room microphone for Skype sessions.

ACOUSTICS: Sound dampening

PIPED SERVICES: No

SIGHTLINES: No

WATER / FLOOR DRAIN: No

MIN. DOOR WIDTH & DESCRIPTION: 42”

TEMPERATURE: Standard

ROOM FINISHES: Standard U.N.O. Floor: Cement finish Base: Walls: Ceiling:

HUMIDITY: Standard

MIN. CEILING HEIGHT: 15’

HAZARDOUS MATERIALS & STORAGE METHOD: No

ADJACENCIES (internal & external): No

FURNITURE, FIXTURES & EQUIPMENT

DATA (qty & type): Provide Category 6A cable to support Wireless connectivity in the space. Provide Category 6A cable to support Audio Visual systems.

VENTILATION: Standard AIR CHANGES: Standard

SPECIAL REQUIREMENTS / NOTES:

MOBILE (qty & type): N/A BUILT-IN (qty & type): A. White Boards on same wall as projection screen FURNITURE (qty & type): B. 50 Chairs C. Lectern D. Lectern Chair

232

-

UNT CVAD Program Report


4.6.2 DESIGN: COMMUNICATION DESIGN CLASS / LAB ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

233


4.6.2 DESIGN: COMMUNICATION DESIGN SPECIAL CLASS / LAB / STUDIO ROOM DETAIL SHEET

Room Detail Sheet : Communication Design – Special / Class / Lab / Studio

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1

ASSIGNABLE SQ. FOOTAGE: 2475 ROOM DIMENSIONS: 45’ X 55’ NUMBER OF OCCUPANTS: 40-45 including instructor (219 capacity: 36-38 students; 1 instructor; 226 capacity; 48 students; 1 instructor) Studio: 21 UTILIZATION (hours/day and general time of day): Seminar room configuration required for: ADES 4630 Fall; T/Th 3 hrs/wk; ADES 3635/3645 Spr; T/Th 6 hrs/wk; ADES 4625 Spr; 3 hrs/wk; ADES 4615 Fall and/or Spr; T/Th 3 hrs/wk IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Communications Design Department, Printmaking, Fibers

BUILDING SYSTEM REQUIREMENTS SECURITY: 24 hour swipe card access TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Adjustability, dimmable fixtures with track lighting along side walls above pinup space POWER (qty & type): Floor cores for tables, power at front of room for instructor computer and projection screen. Duplex in Ceiling for overhead Projector. EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Provide Category 6A cable to floor core locations to support student connectivity, provide floor core location for instructor computer, ensure adequate depth in cores to maintain minimum bend radius of cable. Provide for Wireless connectivity in the space. Provide Category 6A cable to support Audio Visual systems. VOICE (qty & type): No

ACOUSTICS: Standard

AUDIOVISUAL (qty & type): Dual wide aspect ratio projection screens with high definition projectors. Simple, intuitive control system. High quality audio system with listen assist. Digital video and audio inputs at Instructor location. Web camera and room microphone for Skype sessions. HD Video Camera above demonstration table for recording posting on “Blackboard” (online class/ lecture)

SIGHTLINES: No

PIPED SERVICES: Utility Sink

MIN. DOOR WIDTH & DESCRIPTION: @ 36” w; typical

WATER / FLOOR DRAIN: No

ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Tackable Surfaces Ceiling: Ceiling:

TEMPERATURE: Controllable, no need for individual control, just want to have consistency

MIN. CEILING HEIGHT: 10 ‘

AIR CHANGES: Standard

FURNITURE, FIXTURES & EQUIPMENT

HAZARDOUS MATERIALS & STORAGE METHOD: No

WINDOWS / NATURAL LIGHT: Yes, with control for demo/presentations,

MOBILE (qty & type): AV carts (quantity varies); white board BUILT-IN (qty & type): Back Wall full wall length with pegs FURNITURE (qty & type): A. Ideally 2 students per 4 x 6 table B. 17 Training room tables @ 60”w x 24”d C. 34 Stacking chairs D. Lectern E. Lectern Chair F. Instructor House G. Instructor Chair

234

HUMIDITY: Low to medium VENTILATION: Standard

SPECIAL REQUIREMENTS / NOTES: Standardize the classrooms to suit needs of any subjects/sections; flexibility to rearrange setup each day. Space for students to pinup work on walls then stand back far enough to accurately review and critique. Sink used for cleanup when using messy materials. Tables need to be wide enough for each student to lay out work and laptop. Instructor computer / desk setup at back of room so can view students. Instructor uses laptop.

-

UNT CVAD Program Report


4.6.2 DESIGN: COMMUNICATION DESIGN SPECIAL CLASS / LAB / STUDIO ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

235


4.6.2 DESIGN: COMMUNICATION DESIGN RENDER FARM ROOM DETAIL SHEET

Room Detail Sheet : Communication Design – Render Farm

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 600 1200 ROOM DIMENSIONS: 30 x 40 NUMBER OF OCCUPANTS: 10-20 UTILIZATION (hours/day and general time of day): M-F 8-5

IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Comm Design, Student Work Room, Classrooms, Faculty offices, Resource Room, IT WINDOWS / NATURAL LIGHT: No ACOUSTICS: Standard SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: 42” ROOM FINISHES: Standard U.N.O. Floor: carpet Base: Walls: Ceiling:

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard POWER (qty & type): On every wall for flexibility; along wall for computers, floor core for conference table EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Large files/large bandwidth capabilities are required. Provide Category 6A cable from the Telecom room. Consideration for a fiber cable from the Server room to this area to support large file transfers. If fiber backbone is installed there will be a requirement for network equipment in the Render Farm to support connections in room. File transfers are being affected by bandwidth issues when connecting to the Dallas Design Research Center. Provide wireless network coverage this area. Ensure all wireless devices are located in a ceiling or wall enclosure. Provide Power over Ethernet for wireless devices. Provide Category 6A cable to support AV systems. VOICE (qty & type): No AUDIOVISUAL (qty & type): Projection screen and projector. Wide aspect ratio HD display(s). Simple, intuitive control system. High quality audio system with listen assist. Digital video and audio inputs. Web camera and room microphone for Skype sessions. PIPED SERVICES: No

MIN. CEILING HEIGHT: 10 ‘

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type):

A. Tables for Render Farm computers B. Ergonomic chairs C. 1 large conference room table in center of room D. 14 conference chairs E. Whiteboard

236

WATER / FLOOR DRAIN: No TEMPERATURE: Controllable HUMIDITY: No VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: • Currently where department brings guests and treats as seminar room. Place for meetings and place where can spread a lot of work out • If not in same building as server room will need a small IDF room • Will need to be able to connect to the Dallas Design research center • Open late and on weekends -

UNT CVAD Program Report


4.6.2 DESIGN: COMMUNICATION DESIGN RENDER FARM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

237


4.6.2 DESIGN: COMMUNICATION DESIGN SPRAY ROOM ROOM DETAIL SHEET

Room Detail Sheet : Communication Design – Spray Room

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 180 80 ROOM DIMENSIONS: 18’x10’ 8’ X 10’ NUMBER OF OCCUPANTS: 1-3 UTILIZATION (hours/day and general time of day): 7 days/week

IS ROOM SHARED WITH OTHERS? (list group(s)): Could be shared by Interior Design or Fashion Design for mounting work RESOURCES SHARED WITH OTHERS: N/A ADJACENCIES (internal & external): Comm Design Classrooms, Storage Room, Direct adjacency to Student Work Area, Spray Room, Cleanup Room. Resource Room

BUILDING SYSTEM REQUIREMENTS SECURITY: 24hour swipe card access TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard POWER (qty & type): electrical for Spray booth EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): No VOICE (qty & type): No AUDIOVISUAL (qty & type): No PIPED SERVICES: No WATER / FLOOR DRAIN: No

WINDOWS / NATURAL LIGHT: No

TEMPERATURE: HVAC at nights and on weekend. Filtered vertical vacuum for s spray glues.

ACOUSTICS: No

HUMIDITY: Low to medium

SIGHTLINES: No

VENTILATION:

MIN. DOOR WIDTH & DESCRIPTION: 42”

AIR CHANGES: Standard

ROOM FINISHES: Standard U.N.O. Floor: Concrete Base: Walls: Ceiling:

HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: Dedicated space for students to spray their work for mounting and presentations. Need good ventilation governed by OSHA standards.

MIN. CEILING HEIGHT: 10’

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): Counterpace/racks for setting work in progress FURNITURE (qty & type): A. Spray booth with vent hood and ideally a filtered vertical vacuum surface for spraying. B. Racks for Drying

238

-

UNT CVAD Program Report


4.6.2 DESIGN: COMMUNICATION DESIGN SPRAY ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

239


4.6.2 DESIGN: COMMUNICATION DESIGN CLEAN UP / DARK ROOM ROOM DETAIL SHEET

Room Detail Sheet : Communication Design – Clean Up Room / Dark Room

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 150 ROOM DIMENSIONS: 15’ x 10’ NUMBER OF OCCUPANTS: 1 UTILIZATION (hours/day and general time of day): 7 days/week IS ROOM SHARED WITH OTHERS? (list group(s)): Communication Design Association RESOURCES SHARED WITH OTHERS: No

ADJACENCIES (internal & external): Comm Design Classrooms, Resource Room, Storage Room, Student Work Area

BUILDING SYSTEM REQUIREMENTS SECURITY: 24hour swipe card access TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard POWER (qty & type): For Exposure / Projection Unit EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Provide wireless network coverage this area. Ensure all wireless devices are located in a ceiling or wall enclosure. Provide Power over Ethernet for wireless devices. VOICE (qty & type): No AUDIOVISUAL (qty & type): No PIPED SERVICES: Sink

WINDOWS / NATURAL LIGHT: No

WATER / FLOOR DRAIN: No

ACOUSTICS: Standard

TEMPERATURE: Controllable, no need for individual control, just want to have consistency

SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: 42” ROOM FINISHES: Standard U.N.O. Floor: Concrete Base: Walls: Ceiling: MIN. CEILING HEIGHT: 10 ‘

HUMIDITY: Low to medium VENTILATION: Exhaust fan AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: Sink used for cleanup when using messy materials.

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): Large utility sink or spray booth for cleaning larger materials such as screens. Sink needs hand sprayer. FURNITURE (qty & type): A. Projection unit for exposure of screens in separate area/room. B. Racks for drying and storage of screens in separate dark area/room.

240

-

UNT CVAD Program Report


4.6.2 DESIGN: COMMUNICATION DESIGN CLEAN UP / DARK ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

241


4.6.2 DESIGN: COMMUNICATION DESIGN DESIGN / CRITIQUE ROOM DETAIL SHEET

Room Detail Sheet : Communication Design Critique

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 1500 ROOM DIMENSIONS: 30’ x 50’ NUMBER OF OCCUPANTS: 20-24

UTILIZATION (hours/day and general time of day): Standard

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard POWER (qty & type): 110v x 25 outlets EMERGENCY POWER (yes / no, qty.): No

IS ROOM SHARED WITH OTHERS? (list group(s)): No

DATA (qty & type): Provide Category 6A cable to support Wireless connectivity in the space.

RESOURCES SHARED WITH OTHERS: No

VOICE (qty & type): No

ADJACENCIES (internal & external): No

AUDIOVISUAL (qty & type): No

WINDOWS / NATURAL LIGHT: Yes

PIPED SERVICES: No

ACOUSTICS: Sound dampening

WATER / FLOOR DRAIN: No

SIGHTLINES: No

TEMPERATURE: Standard

MIN. DOOR WIDTH & DESCRIPTION: 4’

HUMIDITY: Dry

ROOM FINISHES: Standard U.N.O. Floor: Sealed concrete Base: Walls: Ceiling:

VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No

MIN. CEILING HEIGHT: 10’ SPECIAL REQUIREMENTS / NOTES:

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): Pinup space on all walls to review work. FURNITURE (qty & type): A. 24 Chairs

242

-

UNT CVAD Program Report


4.6.2 DESIGN: COMMUNICATION DESIGN DESIGN / CRITIQUE ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

243


4.6.2 DESIGN: COMMUNICATION DESIGN RESOURCE ROOM ROOM DETAIL SHEET

Room Detail Sheet : Communication Design – Resource Room

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 600 625 ROOM DIMENSIONS: 15’ x 25’ 25’ x 25’ NUMBER OF OCCUPANTS: 15 5 UTILIZATION (hours/day and general time of day): 7 days/week

IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Comm Design Classrooms, Storage Room, Direct adjacency to Student Work Area, Spray Room, Cleanup Room. Centrally located among department WINDOWS / NATURAL LIGHT: Preferred ACOUSTICS: Standard

BUILDING SYSTEM REQUIREMENTS SECURITY: 24hour swipe card access TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard POWER (qty & type): 15 plugs for laptop stations, 1 plug for student worker, plugs along wall for equipment EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Provide Category 6A cable from the Telecom room to support a total of 15 data ports. Provide wireless network coverage this area. Ensure all wireless devices are located in a ceiling or wall enclosure. Provide Power over Ethernet for wireless devices. VOICE (qty & type): No AUDIOVISUAL (qty & type): No PIPED SERVICES: No WATER / FLOOR DRAIN: No

SIGHTLINES: No

TEMPERATURE: Controllable, no need for individual control, just want to have consistency. HVAC at nights and on weekend

MIN. DOOR WIDTH & DESCRIPTION: 42”

HUMIDITY: Low to medium for paper, books and equipment

ROOM FINISHES: Standard U.N.O. Floor: Carpet Base: Walls: Ceiling:

VENTILATION: AIR CHANGES: Standard

MIN. CEILING HEIGHT: 10’

FURNITURE, FIXTURES & EQUIPMENT

HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: Space for use of books and binding/cutting materials that students utilize. Opens up to student workroom ideally. Cutting machines, equipment for binding and trimming paper, and scanners will be used in room.

MOBILE (qty & type): N/A BUILT-IN (qty & type): Counterpace for current binding/cutting/assembly materials. Work wall with plugs and work surface for students to plug laptop into (15 spots total) FURNITURE (qty & type):

A.40 Linear feet 8’H bookcases, min. lining perimeter B. 3-6 desks for student workers and visitors C. 3- 6 task chairs D. Flat files to store physical imagery

244

-

UNT CVAD Program Report


4.6.2 DESIGN: COMMUNICATION DESIGN RESOURCE ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

245


4.6.2 DESIGN: COMMUNICATION DESIGN STORAGE ROOM ROOM DETAIL SHEET

Room Detail Sheet : Communication Design – Storage Room

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 400 ROOM DIMENSIONS: 20 x 20’ NUMBER OF OCCUPANTS: 2-3 UTILIZATION (hours/day and general time of day): M-F 8-5

BUILDING SYSTEM REQUIREMENTS SECURITY: 24hour swipe card access TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard POWER (qty & type): Convenience outlets EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): No

IS ROOM SHARED WITH OTHERS? (list group(s)): No

VOICE (qty & type): No

RESOURCES SHARED WITH OTHERS: No

AUDIOVISUAL (qty & type): No

ADJACENCIES (internal & external): Comm Design Faculty offices

PIPED SERVICES: No

WINDOWS / NATURAL LIGHT: No ACOUSTICS: No SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: 42” ROOM FINISHES: Standard U.N.O. Floor: Concrete Base: Walls: Ceiling: MIN. CEILING HEIGHT: 10’

WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Low to medium VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: Used to store Comm Design materials and resources used in classrooms as well as student work for reviews and accreditations.

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): A. flat files B. 5-high lockable file cabinets C. 5-high open shelving

246

-

UNT CVAD Program Report


4.6.2 DESIGN: COMMUNICATION DESIGN STORAGE ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

247



4.6.3 Fashion Design 4.6.3

The University of North Texas

The following area makes up the Fashion Design program. The program’s focus is on industry methods combining the teaching of the history of fashion with the use of modern technology. Technology is an increasingly important focus of the program. True natural light is critical for Fashion Design students as well as artificial light that replicates natural light. The classrooms need to be a lecture style classroom used for a variety of classes and their flexibility is crucial to their operation. The department would best be housed adjacent to the Texas Fashion Collection and in close proximity to the Fibers program. Additional specific program requirements can be found in the following Room Detail Sheets, Room Layouts, and the Space Program List.


4..6.3 DESIGN FASHION DESIGN PROGRAM ADJACENCY DIAGRAM

250

-

UNT CVAD Program Report


4..6.3 DESIGN FASHION DESIGN VISUAL PROGRAM

-

UNT CVAD Program Report

251


4..6.3 DESIGN FASHION DESIGN SPACE PROGRAM Space Name Position

Circulation Factor

Room Number

2013

2016

Number Assignable of Spaces S/F

Number Unit Area of Spaces

Total Area

Fashion Design Faculty Offices Professor - Li-Fen Anny Change Professor - Marian O'Rourke Kaplan Professor - Janie Stidham Professor - Myra Walker Professor - Diana Beard Faculty Growth - Professor Classrooms Design/Studio/Lecture Room Special Class/Lab/Lecture Room Studios Knitting Studio CAD Studio Graduate Studios Support Spaces Critique Room Storage Room Total Spaces Assignable Square Feet Net to Gross @ 45% = Assignable SF x (1/(1-45%))= Department Gross SF

252

Scou 112B Scou 112C Scou 112F Scou 112D Scou 112E N/A

1 1 1 1 1 0

164 101 189 120 102 0

1 1 1 1 1 1

130 130 130 130 130 130

130 130 130 130 130 130

Scou 209/109 Scou 215

1 1

1858 637

3 1

1500 900

4,500 900

Scou 209 N/A N/A

1 0 0

778 0 0

1 1 4

900 2000 300

900 2,000 1,200

N/A Scou 209A/B/112A

0 1

0 145

1 1

900 120

900 120

9 0.8181

18 4,094 3,349

11,300 9,245

7,443

20,545

-

UNT CVAD Program Report


Adele Simpson -

UNT CVAD Program Report

253


4.6.3 DESIGN: FASHION DESIGN CLASS / LAB / STUDIO ROOM DETAIL SHEET

Room Detail Sheet : Fashion Design Class / Lab / Studio

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 2 ASSIGNABLE SQ. FOOTAGE: 1400 (1500) ROOM DIMENSIONS: 30’ x 47’ (30’ x 50’)

NUMBER OF OCCUPANTS: 21 (20 students, 1 instructor) UTILIZATION (hours/day and general time of day): 8am-5pm, M-F, evening & weekend open lab IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Flexible Lecture / Presentation classroom WINDOWS / NATURAL LIGHT: Yes, abundant ACOUSTICS: Standard SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Larger to accommodate equipment. 42” width minimum

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Lamps to provide as close to natural light as possible POWER (qty & type): Outlets to support equipment specified in the equipment list; 4x11 for convenience EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Provide wireless network coverage this area. Ensure all wireless devices are located in a ceiling or wall enclosure. Provide Power over Ethernet for wireless devices. Provide Category 6A cable from the Telecom room to support AV systems. VOICE (qty & type): No AUDIOVISUAL (qty & type): Dual wide aspect ratio projection screens with high definition projectors. Simple, intuitive control system. High quality audio system with listen assist. Digital video and audio inputs at Instructor location. Web camera and room microphone for Skype sessions. Demonstration camera for viewing by class. Recording capabilities in order to post to UNT’s “Blackboard”. PIPED SERVICES: No

ROOM FINISHES: Standard U.N.O. Floor: linoleum or other “springy” floor Base: Walls: Ceiling:

WATER / FLOOR DRAIN: No

MIN. CEILING HEIGHT: Higher ceiling height than standard.

VENTILATION: Standard

TEMPERATURE: Standard HUMIDITY: Standard; see mobile dehumidifier under equipment list

AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): A. 11 - Cutting tables with self healing cork tops (two students per table) B. 21 - Stools with 22”dia x 40”h (adjustable height) C. 20 - stacking chairs 18”w x 22”d x 31”h D. Thread rack/Pegboard 36”w x 37”d x 36”h E. Hemming platform 36”w x 36”d x 17”d F. 21 - Sewing machines – Juki DDL-8300 N single needle on table 55”l x 20d” 48”h G. 5 - Sergers 61”l x 20”d x 48”h (includes industrial) H. Pressing stations – Hi Steam PND-2500A 73”l x 21”d x 53”h

254

SPECIAL REQUIREMENTS / NOTES: • One of these studios needs to be technology-based • Two students per work table to work on design and construction of garment; including space to develop pattern and cut out of fabric. • Adjacent space for a dress form to drape designs and fit muslins’ also space for a sewing machine to sew. I. Dress forms (4 full-body women, 22 regular women, 1 – child fully body) J. Instructor table. K. Instructor chair L. 3-way mirror fitting studio suitable for 20 students (4 section folding) 124”l x 2 ½”d x 79”h M. White board

N. 1-pattern pegboard 144”l x 6”d x 6”h O. Dehumidifier (floor/mobile) 15”l x 11”d x 24”h -

UNT CVAD Program Report


4.6.3 DESIGN: FASHION DESIGN CLASS / LAB / STUDIO ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

255


4.6.3 DESIGN: FASHION DESIGN SPECIAL CLASS / LAB / LECTURE ROOM DETAIL SHEET

Room Detail Sheet : Fashion Design Special Class / Lab / Lecture

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design

BUILDING SYSTEM REQUIREMENTS

ROOM QUANTITY: 1

SECURITY: Lockable

ASSIGNABLE SQ. FOOTAGE: 1200

TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Lams to provide as close to natural light as possible.

ROOM DIMENSIONS: 30’ x 40’ NUMBER OF OCCUPANTS: (60) UTILIZATION (hours/day and general time of day): 8-5, M-F IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): • Fashion History class needs to be adjacent to Texas Fashion Collection (TFC) – needs a separate classroom • Fashion lecture room also needs to be near Texas Fashion Collection because use the garments sometimes for classroom purposes • Adjacency: Lecture Hall – CAD Studio – needs to be same building as TFC, prefer same floor WINDOWS / NATURAL LIGHT: No, needs to be appropriate for audio/visual ACOUSTICS: yes SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Larger for equipment ROOM FINISHES: Standard U.N.O. Floor: Linoleum or other for “springy” floor. Base: Walls:

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): A. 30 Tables, 60”l x 24”d x 30”h (2 students per table) B. 60 Stackable chairs C. Podium D. Demonstraction table with camera and cap at table E. Instructor chair

256

POWER (qty & type): Outlets to support equipment specified in the equipment list; 4x120v for convenience EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Provide wireless network coverage to this area. Ensure all wireless devices are located in a ceiling or wall enclosure. Provide Power over Ethernet for wireless devices. Provide Category 6A cable from the Telecom room to support AV systems. VOICE (qty & type): No AUDIOVISUAL (qty & type): Dual wide aspect ratio projection screens with high definition projectors. Simple, intuitive control system. High quality audio system with listen assist. Digital video and audio inputs at Instructor location. Web camera and room microphone for Skype sessions. Demonstration camera for viewing by class. PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: • Tables in classrooms have self healing cork surfaces. (Claridge Cork) • Must have 2 points of egress to meet code but want to make them arranged so there is a clear entrance and the secondary door is not used • Demonstration table needs camera that can be projected on the wall • Need one of the studio rooms to be technology based • Flexibility key for the various lecture classes: Intro, Professional Practices, History of Costume, Graduate Student Seminars, Industry Critics, and Gallery seating.

-

UNT CVAD Program Report


4.6.3 DESIGN: FASHION DESIGN SPECIAL CLASS / LAB / LECTURE ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

257


4.6.3 DESIGN: FASHION DESIGN KNITTING STUDIO ROOM DETAIL SHEET

Room Detail Sheet : Fashion Design Knitting Studio

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 1020 (900) ROOM DIMENSIONS: 32’ x 32’ (30’ x 30’)

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard

NUMBER OF OCCUPANTS: 16 (15 students + 1 instructor)

POWER (qty & type): Outlets to support equipment specified in the equipment list; 4x120v for convenience

UTILIZATION (hours/day and general time of day): 8-5, M-F

EMERGENCY POWER (yes / no, qty.): No

IS ROOM SHARED WITH OTHERS? (list group(s)): No

ADJACENCIES (internal & external): Fashion Studio

DATA (qty & type): Provide wireless network coverage this area. Ensure all wireless devices are located in a ceiling or wall enclosure. Provide Power over Ethernet for wireless devices. Provide Category 6A cable from the Telecom room to support AV systems.

WINDOWS / NATURAL LIGHT: Yes, abundant

VOICE (qty & type): No

ACOUSTICS: Standard

AUDIOVISUAL (qty & type): Dual wide aspect ratio projection screens with high definition projectors. Simple, intuitive control system. High quality audio system with listen assist. Digital video and audio inputs at Instructor location. Web camera and room microphone for Skype sessions. Demonstration camera for viewing by class.

RESOURCES SHARED WITH OTHERS: No

SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Large for equipment (measurements undetermined at this time) ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling: MIN. CEILING HEIGHT: Higher than standard

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): A. 5 Knitting machines, B. 2 Computer/CAD station, C. 3 Work tables, D. 2 Pressing stations, Hi-Steam PND-2500 73”l x 21”d x 53”h F. Instructor knitting machine and table G. Instructor chair H. 16 stools, 22”dia x 40”h (adjustable height)

258

PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: • This will be a new addition to the fashion program. Therefore equipment and dimensions are undetermined.

-

UNT CVAD Program Report


4.6.3 DESIGN: FASHION DESIGN KNITTING STUDIO ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

259


4.6.3 DESIGN: FASHION DESIGN CAD STUDIO ROOM DETAIL SHEET

Room Detail Sheet : Fashion Design CAD Studio

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1

ASSIGNABLE SQ. FOOTAGE: 1400 (1500) + (200) = 1700 ROOM DIMENSIONS: 30’ x 50’ with an 12’ x 16’ sectioned off for CAD equipment (glass sliding door) (30’ x 50’) + (12’ x 16’)

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable, Card Access TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard POWER (qty & type): Outlets to support equipment specified in the equipment list; 4x120v for convenience

NUMBER OF OCCUPANTS: 21 (20 student, 1 instructor)

EMERGENCY POWER (yes / no, qty.): No

UTILIZATION (hours/day and general time of day): 8am-5pm, M-F

DATA (qty & type): Provide Category 6A cable from the Telecom room. Provide wireless network coverage this area. Ensure all wireless devices are located in a ceiling or wall enclosure. Provide Power over Ethernet for wireless devices. Provide Category 6A cables from the Telecom room to support AV systems. High bandwidth application may benefit from having a fiber backbone from the Telecom Room and deploying a network switch in the room.

IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Lecture WINDOWS / NATURAL LIGHT: Yes (except for sectioned off area) ACOUSTICS: Standard SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: 42” min. ROOM FINISHES: Standard U.N.O. Floor: linoleum or other “springy” floor Base: Walls: Ceiling: MIN. CEILING HEIGHT: Higher than standard

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): *Furniture the same as Class/Lab /Studio with additional CAD equipment:

VOICE (qty & type): No AUDIOVISUAL (qty & type): Camera above instructor demonstration table projecting to screen with recording capabilities for posting to UNT “Blackboard”. PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Standard; see mobile dehumidifier under the equipment list VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: • Same furniture and equipment as Class / Lab / Studio but with additional computer equipment in the CAD room. • Quantity of Sergers in this room should be 2 rather than 5.

P. Coverstitch Machine and table, 46 ½”l x 21”d x 61”h Q. Computer workstation – 35 SF area R. Digitizer – Numonics Corp. CNT/OPD I, 67”w x 48”d x 70”h G. Plotter – HP Designjet #500, 67”w x 33”d x 42”h

260

-

UNT CVAD Program Report


4.6.3 DESIGN: FASHION DESIGN CAD STUDIO ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

261


4.6.3 DESIGN: FASHION DESIGN CRITIQUE ROOM DETAIL SHEET

Room Detail Sheet : Fashion Design Critique

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design

BUILDING SYSTEM REQUIREMENTS

ROOM QUANTITY: 1

SECURITY: Lockable

ASSIGNABLE SQ. FOOTAGE: 900

TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Lamps to provide as close to natural light as possible

ROOM DIMENSIONS: 30’ x 30' NUMBER OF OCCUPANTS: 25

POWER (qty & type): 110v x 25 outlets EMERGENCY POWER (yes / no, qty.): No

UTILIZATION (hours/day and general time of day): 8-5, M-F

DATA (qty & type): Provide Category 6A cable to support Wireless connectivity.

IS ROOM SHARED WITH OTHERS? (list group(s)): No

VOICE (qty & type): No

RESOURCES SHARED WITH OTHERS: No

AUDIOVISUAL (qty & type): No

ADJACENCIES (internal & external): Studios

PIPED SERVICES: No

WINDOWS / NATURAL LIGHT: Yes

WATER / FLOOR DRAIN: No

ACOUSTICS: Sound dampening

TEMPERATURE: Standard

SIGHTLINES: No

HUMIDITY: Dry

MIN. DOOR WIDTH & DESCRIPTION: 3’ 6”

VENTILATION: Standard

ROOM FINISHES: Standard U.N.O. Floor: Sealed concrete Base: Walls: Ceiling:

AIR CHANGES: Standard

MIN. CEILING HEIGHT: 10’

HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: • Room can also be used for photo shoots in lieu of the lecture room, which requires space for backdrops and camera equipment.

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): A. 25 Chairs

262

-

UNT CVAD Program Report


4.6.3 DESIGN: FASHION DESIGN CRITIQUE ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

263


4.6.3 DESIGN: FASHION DESIGN SEWING PRODUCTION WORKROOM ROOM DETAIL SHEET

Room Detail Sheet : Fashion Design Sewing Production Workroom

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 1020 (900) ROOM DIMENSIONS: 32’ x 32’ (30’ x 30’) NUMBER OF OCCUPANTS: 16

UTILIZATION (hours/day and general time of day): 8-5, M-F IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Studio WINDOWS / NATURAL LIGHT: Yes, abundant ACOUSTICS: Standard SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Large for equipment (measurements undetermined at this time)

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard POWER (qty & type): Standard EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Provide wireless network coverage this area. Ensure all wireless devices are located in a ceiling or wall enclosure. Provide Power over Ethernet for wireless devices. Provide Category 6A cable from the Telecom room to support AV systems. VOICE (qty & type): No AUDIOVISUAL (qty & type): No PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Standard

ROOM FINISHES: Standard U.N.O. Floor: linoleum or other “springy” floor Base: Walls: Ceiling:

HUMIDITY: Standard

MIN. CEILING HEIGHT: Higher than standard

HAZARDOUS MATERIALS & STORAGE METHOD: No

FURNITURE, FIXTURES & EQUIPMENT

SPECIAL REQUIREMENTS / NOTES:

MOBILE (qty & type): N/A

VENTILATION: Standard AIR CHANGES: Standard

BUILT-IN (qty & type): N/A FURNITURE (qty & type): A. 15 Sewing machines B. 15 Stacking chairs C. 15 Dress forms D. 4 Cutting tables with self-healing cork tops, 72”l x 36”d, 48”h E. 1 Pressing Station

F. 2 Sergers, 61”l x 20”d x 48”h G. 6 Stools 22”dia x 40”h (adjustable height)

264

-

UNT CVAD Program Report


4.6.3 DESIGN: FASHION DESIGN SEWING PRODUCTION WORKROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

265


4.6.3 DESIGN: FASHION DESIGN STORAGE ROOM DETAIL SHEET

Room Detail Sheet : Fashion Design Storage

University of North Texas SPACE REQUIREMENTS College of Visual3 Arts + Design ROOM QUANTITY: ASSIGNABLE SQ. FOOTAGE: 120 ROOM DIMENSIONS: 10’ x 12’ NUMBER OF OCCUPANTS: 0

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard POWER (qty & type): No EMERGENCY POWER (yes / no, qty.): No

UTILIZATION (hours/day and general time of day): 8am-5pm, M-F

DATA (qty & type): No

IS ROOM SHARED WITH OTHERS? (list group(s)): No

VOICE (qty & type): No

RESOURCES SHARED WITH OTHERS: No

AUDIOVISUAL (qty & type): No

ADJACENCIES (internal & external): Next to faculty offices

PIPED SERVICES: No

WINDOWS / NATURAL LIGHT: No

WATER / FLOOR DRAIN: No

ACOUSTICS: No

TEMPERATURE: Standard

SIGHTLINES: No

HUMIDITY: Standard

MIN. DOOR WIDTH & DESCRIPTION: Double doors for easy clothing rack access.

VENTILATION: Standard

ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling: MIN. CEILING HEIGHT: Standard

AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: N/A ROOM USES: Students turn in their work on the rolling racks; storage of instructor chairs, plot paper, fabrics.

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): Shelving FURNITURE (qty & type):

A. 2 Existing chrome shelving frames 12”d x “84”h B. 2 - 37”l x “12”d x “97”h shelving units C. 2- 12”d x 48”h metal rolling racks D. 2 Wall mounted wood shelves 47”l x 12”d x 5” h ea.

266

-

UNT CVAD Program Report


4.6.3 DESIGN: FASHION DESIGN STORAGE ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

267



4.6.4 Fibers

The University of North Texas

The following information makes up the Fibers program. The program goals are to adequately educate students on a variety of techniques and train students on numerous types of equipment. Technology is needed to update the Fibers program and to compete with schools that have nationally recognized and respected Fibers programs. Adequate ventilation systems and humidity control are required in the studio areas. Adequate space allocation for all areas is vital to properly use and service the machines. Fibers and Printmaking have a natural affinity and can be located adjacent to one another. Additional program information is located in the following Room Detail Sheets, Room Layouts and the Space Program List.


4.6.4 DESIGN FIBERS PROGRAM ADJACENCY DIAGRAM

270

-

UNT CVAD Program Report


4.6.4 DESIGN FIBERS VISUAL PROGRAM

-

UNT CVAD Program Report

271


4.6.4 DESIGN FIBERS SPACE PROGRAM Space Name Position

Circulation Factor

Room Number

2013

2016

Number Assignable of Spaces S/F

Number Unit Area of Spaces

Total Area

Fibers Faculty Offices Professor - Amie Adelman Professor - Lesli Robertson Adjunct Faculty Growth - Professor Classrooms Critique/Lecture Room Studios Graduate Studios Weaving I Studio Advanced Weaving Studio Computerized Weaving Studio Digital Printing Studio Knitting and Sewing and Off-Loom Weaving Studio Papermaking Studio Screenprinting/Surface Design Studio Surface Design Studio Support Spaces Washout Booth Darkroom Exposure Unit Room Chemical Room Warping Room Resource Room Advanced Weaving Knitting Supply Closet Total Spaces Assignable Square Feet Net to Gross @ 45% = Assignable SF x (1/(1-45%))= Department Gross SF

272

Scou 221 Scou 221 Scou 124D N/A

1 1 1 0

357 0 115 0

1 1 1 1

130 130 65 130

130 130 65 130

N/A

0

0

1

900

900

N/A Bain 101 Scou 229 Scou 128A Scou 114 Scou 128 N/A Scou 226 Scou 212

0 1 1 1 1 1 0 1 1

0 817 846 80 115 413 0 1213 1245

9 1 1 1 1 1 1 1 1

300 1500 1500 300 900 900 600 1500 1500

2700 1500 1500 300 900 900 600 1500 1500

Scou 226 (partial) Scou 226B Scou 226A Scou 223 Bain 209 N/A Scou 112B

1 1 1 1 1 0 1

0 64 204 118 247 0 164

1 1 1 1 1 1 1

300 300 300 300 600 300 300

300 300 300 300 600 300 300

16 0.8181

29 5,998 4,907

15,155 12,398

10,905

27,553

-

UNT CVAD Program Report


-

UNT CVAD Program Report

273


4.6.4 DESIGN: FIBERS CRITIQUE / LECTURE ROOM ROOM DETAIL SHEET

Room Detail Sheet : Fibers Critique/Lecture Room

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 500 ROOM DIMENSIONS: 20’ x 25’ (30 x 30) NUMBER OF OCCUPANTS: 19-24

UTILIZATION (hours/day and general time of day): Standard

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard POWER (qty & type): Standard EMERGENCY POWER (yes / no, qty.): No

IS ROOM SHARED WITH OTHERS? (list group(s)): No

DATA (qty & type): Provide Category 6A cable to support Wireless connectivity and Audio Visual systems.

RESOURCES SHARED WITH OTHERS: No

VOICE (qty & type): No

ADJACENCIES (internal & external): Surface design rooms

ACOUSTICS: No

AUDIOVISUAL (qty & type): Dual wide aspect ratio projection screens with high definition projectors. Simple, intuitive control system. High quality audio system with listen assist. Digital video and audio inputs at Instructor location. Web camera and room microphone for Skype sessions.

SIGHTLINES: No

PIPED SERVICES: No

MIN. DOOR WIDTH & DESCRIPTION: Double Doors, 42” width min.

WATER / FLOOR DRAIN: No

WINDOWS / NATURAL LIGHT: Yes

ROOM FINISHES: Standard U.N.O. Floor: Sealed concrete Base: Walls: Ceiling:

TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Standard AIR CHANGES: Standard

MIN. CEILING HEIGHT: 10’

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A

HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: Photo equipment, Homasote on all walls for pin-up space A. A/V Cabinet

FURNITURE (qty & type): Standard

274

-

UNT CVAD Program Report


4.6.4 DESIGN: FIBERS CRITIQUE / LECTURE ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

275


4.6.4 DESIGN: FIBERS WEAVING I STUDIO ROOM DETAIL SHEET

Room Detail Sheet : Fibers Weaving I Studio

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 1500 ROOM DIMENSIONS: 30’ x 50’ NUMBER OF OCCUPANTS: 17-20 UTILIZATION (hours/day and general time of day): 8am to 8pm, M-Th, Fridays

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Color rendering fixtures POWER (qty & type): 120v x 18 outlets EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): No

IS ROOM SHARED WITH OTHERS? (list group(s)): No

VOICE (qty & type): No

RESOURCES SHARED WITH OTHERS: No

AUDIOVISUAL (qty & type): Dual wide aspect ratio projection screens with high definition projectors. Simple, intuitive control system. High quality audio system with listen assist. Digital video and audio inputs at Instructor location.

ADJACENCIES (internal & external): Warping Room WINDOWS / NATURAL LIGHT: Yes ACOUSTICS: Sound dampening SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Double Doors, 42” wide min. ROOM FINISHES: Standard U.N.O. Floor: Stained concrete Base: Walls: Ceiling:

PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Dry VENTILATION: Heavy duty ventilation required. Vent hood for mixing dyes and chemicals. AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No

MIN. CEILING HEIGHT: Standard

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A

SPECIAL REQUIREMENTS / NOTES: • Rectangular room layout preferred • Paper towel dispensers needed

FURNITURE (qty & type): A. 18 looms B. 18 Benches for Looms C.1 Washout Booth D. 4 Tables E. Secure Yarn Storage F. Homasote board

276

-

UNT CVAD Program Report


4.6.4 DESIGN: FIBERS WEAVING 1 STUDIO ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

277


4.6.4 DESIGN: FIBERS ADVANCED WEAVING STUDIO ROOM DETAIL SHEET

Room Detail Sheet : Fibers Advanced Weaving Studio

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 1500 ROOM DIMENSIONS: 30’ x 50’ NUMBER OF OCCUPANTS: 17-20 UTILIZATION (hours/day and general time of day): 8am to 8pm, M-Th, Fridays

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Color rendering fixtures POWER (qty & type): 120v x 18 outlets, ceiling outlets required with hanging extension cords. EMERGENCY POWER (yes / no, qty.): No

IS ROOM SHARED WITH OTHERS? (list group(s)): No

DATA (qty & type): Provide Category 6A cable to support Audio Visual systems.

RESOURCES SHARED WITH OTHERS: No

VOICE (qty & type): No

ADJACENCIES (internal & external): Attached to computerized weaving studio

AUDIOVISUAL (qty & type): Dual wide aspect ratio projection screens with high definition projectors. Simple, intuitive control system. High quality audio system with listen assist. Digital video and audio inputs at Instructor location. Web camera and room microphone for Skype sessions.

WINDOWS / NATURAL LIGHT: Yes ACOUSTICS: Sound dampening SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Double doors, 42” wide min. ROOM FINISHES: Standard U.N.O. Floor: Stained concrete, non-slip Base: Walls: Ceiling:

PIPED SERVICES: Stove with 4 burners WATER / FLOOR DRAIN: Stainless steel sinks, Floor drain TEMPERATURE: Standard HUMIDITY: Dry VENTILATION: Heavy dust ventilation and (1) vent hood for mixing dyes and chemicals, and (1) vent hood for print table vapors AIR CHANGES: Standard

MIN. CEILING HEIGHT: Standard

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): A. 1 vertical steamer

BUILT-IN (qty & type): B. Stainless steel counters with storage underneath C. vent hood for mixing dyes and chemicals, storage for extra reeds (2’-2 ½” x 1’ x 2’-1/2”), 3 shelves (16’ x 1’-4” x 3’-1”) FURNITURE (qty & type): D.18 floor looms (4’-3” tall x 4’ wide x 3’-2” some are larger) E. 18 benches for floor looms F. Inkle looms G. 2 Saganishki looms H. 1 Vertical loom I. 2 Warping reels J. 1 Spinning wheel K. 1 Yarn spooler L. Table Loom M. Critique walls with 5 - 4’ x 8’ homasote panels

278

HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: 15 warping boards in hallway and extend from the wall 6”, Square or rectangular configuration preferred, required, paper towel dispensers needed

N.18 benches (2’ tall x 3’-2” wide x 10”) O. 8 metal stools, P. Instructor Chair Q. 1 table (5’ x 2’-6” x 2’-5”) R. Dry erase board, boards- gridded and blank, S. Lockers T. Yarn Storage (16’ x 9 ½” x 4’) U. Print table for printing warps V. 2 Worktables, 6’ x 3’ W. Stove (with four burners) Clothesline

-

UNT CVAD Program Report


4.6.4 DESIGN: FIBERS ADVANCED WEAVING STUDIO ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

279


4.6.4 DESIGN: FIBERS COMPUTERIZED WEAVING STUDIO ROOM DETAIL SHEET

Room Detail Sheet : Fibers Computerized Weaving Studio

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 300 ROOM DIMENSIONS: 15’ x 20’ NUMBER OF OCCUPANTS: 17-20 UTILIZATION (hours/day and general time of day): 8am to 8pm, M-Th, Fridays

IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Color rendering fixtures, 4x lights POWER (qty & type): 120v x 4 outlets EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Provide Category 6A cable from the nearest Telecom Room to support one data connection for Internet access. VOICE (qty & type): No AUDIOVISUAL (qty & type): No

ADJACENCIES (internal & external): Located next to or within advanced weaving studio

PIPED SERVICES: No

WINDOWS / NATURAL LIGHT: Yes

WATER / FLOOR DRAIN: No

ACOUSTICS: Sound dampening

TEMPERATURE: Standard

SIGHTLINES: No

HUMIDITY: Dry

MIN. DOOR WIDTH & DESCRIPTION: Double door, 42” width min.

VENTILATION: Air Purifier

ROOM FINISHES: Standard U.N.O. Floor: Stained concrete, non-slip Base: Walls: Ceiling:

AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES:

MIN. CEILING HEIGHT: Standard

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): A.1 AVL Compu-dobby loom B. 2 Jacquared TC-2 looms with updated software C.1 computer workstation for AVL loom with updated software, printer, (Square or rectangular configuration preferred) D. Computer workstation for Jacquared TC-2 looms E.1 Steel computer cabinet

280

-

UNT CVAD Program Report


4.6.4 DESIGN: FIBERS COMPUTERIZED WEAVING STUDIO ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

281


4.6.4 DESIGN: FIBERS DIGITAL PRINTING STUDIO ROOM DETAIL SHEET

Room Detail Sheet : Fibers Digital Printing Studio

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 800-1000 900 ROOM DIMENSIONS: 25’ x 40’ 30’ x 30’ NUMBER OF OCCUPANTS: 17-20 UTILIZATION (hours/day and general time of day): 8am to 8pm, M-Th, Fridays

IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Computerized weaving studio WINDOWS / NATURAL LIGHT: Yes ACOUSTICS: No SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Double door, 42” wide min. ROOM FINISHES: Standard U.N.O. Floor: Stained concrete Base: Walls: Ceiling: MIN. CEILING HEIGHT: Standard

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Color rendering fixtures, 4v lights POWER (qty & type): 120v x 5 outlets EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Provide Category 6A cable from the nearest Telecom Room to support seven network/printer connections. Provide Category 6A cable to support Wireless connectivity and Audio Visual systems. VOICE (qty & type): Provide Category 6A cable from the nearest Telecom Room to support required voice connections. AUDIOVISUAL (qty & type): No PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Humidity control required to maintain paper backed fabric VENTILATION: Air Purifier AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: No

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): Dowel rods for storing fabric – built-in yet easily movable FURNITURE (qty & type): A. Sapphire large format digital printer B. 1 TX1600s large format digital printer C. 3 computer workstations D.1 Metal cabinet E.1 computer workstation for 2 computers F. Table for drying printed fabric G. Homasote panels

282

-

UNT CVAD Program Report


4.6.4 DESIGN: FIBERS DIGITAL PRINTING STUDIO ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

283


4.6.4 DESIGN: FIBERS KNITTING AND SEWING / OFF-LOOM WEAVING STUDIO ROOM DETAIL SHEET

Room Detail Sheet : Fibers Knitting and Sewing and Off-Loom Weaving Studio

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 1000 900 ROOM DIMENSIONS: 25’ x 40’ 30’ x 30’ NUMBER OF OCCUPANTS: 17-20 UTILIZATION (hours/day and general time of day): 8am to 8pm, M-Th, Fridays

IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Computerized weaving studio

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Color rendering fixtures POWER (qty & type): 120v x 25 outlets EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Provide Category 6A cable from the nearest Telecom Room to support sixteen network connections for computers and printers. Provide Category 6A cable to support Wireless connectivity and Audio Visual systems. VOICE (qty & type): 7 computerized knitting machines

ACOUSTICS: No

AUDIOVISUAL (qty & type): Dual wide aspect ratio projection screens with high definition projectors. Simple, intuitive control system. High quality audio system with listen assist. Digital video and audio inputs at Instructor location. Web camera and room microphone for Skype sessions.

SIGHTLINES: No

PIPED SERVICES: No

MIN. DOOR WIDTH & DESCRIPTION: Standard

WATER / FLOOR DRAIN: Stainless steel sinks

ROOM FINISHES: Standard U.N.O. Floor: Stained concrete Base: Walls: Ceiling:

TEMPERATURE: Standard

MIN. CEILING HEIGHT: Standard

AIR CHANGES: Standard

WINDOWS / NATURAL LIGHT: Yes

FURNITURE, FIXTURES & EQUIPMENT

HUMIDITY: Humidity control required to maintain paper backed fabric VENTILATION: No

HAZARDOUS MATERIALS & STORAGE METHOD: No

MOBILE (qty & type): N/A BUILT-IN (qty & type): A. Locking cabinet for yarn, stainless steel counter with storage underneath FURNITU0RE (qty & type): B. 15 tables for each knitting machine C.15 chairs, D. 10 computer workstations E. Lockers F. metal shelves G. 7 computerized knitting machines

284

SPECIAL REQUIREMENTS / NOTES: Square or rectangular configuration preferred

H. 8 knitting machine I. Critique walls with Homasote required, J. 1 serger K. 9 computers L. 1 scanner M. 3 computerized sewing machines

-

UNT CVAD Program Report


4.6.4 DESIGN: FIBERS KNITTING AND SEWING / OFF-LOOM WEAVING STUDIO ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

285


4.6.4 DESIGN: FIBERS PAPERMAKING STUDIO ROOM DETAIL SHEET

Room Detail Sheet : Fibers Papermaking Studio

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 1000 600 ROOM DIMENSIONS: 25’ x 40’ 30’x 20’ NUMBER OF OCCUPANTS: 17-20 UTILIZATION (hours/day and general time of day): 8am to 8pm, M-Th, Fridays

IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Color rendering fixtures POWER (qty & type): 120v x 10 outlets EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Provide Category 6A cable to support Audio Visual systems. VOICE (qty & type): No

WINDOWS / NATURAL LIGHT: Yes

AUDIOVISUAL (qty & type): Dual wide aspect ratio projection screens with high definition projectors. Simple, intuitive control system. High quality audio system with listen assist. Digital video and audio inputs at Instructor location. Web camera and room microphone for Skype sessions.

ACOUSTICS: No

PIPED SERVICES: Stove with 4 burners

SIGHTLINES: No

WATER / FLOOR DRAIN: Stainless steel sinks and drainage system in floor

ADJACENCIES (internal & external): Between fibers and printingmaking

MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: Stained concrete, non-slip with drainage floor Base: Walls: Ceiling:

TEMPERATURE: Standard HUMIDITY: Humidity control required to maintain paper backed fabric VENTILATION: Standard AIR CHANGES: Standard

MIN. CEILING HEIGHT: Standard

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): I. Locking cabinets J. Stainless steel counters with storage underneath

HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: • Square or rectangular configuration preferred,

FURNITURE (qty & type): A.1 Hollander 3’-6” tall x 4’-3” wide x 2’-5” deep B. 4 Large pots C. l Large hydraulic paper press D.1 4’ x 6’ vacuum table E.1 Paper drying box F.1 Hydropulper and mixer G.1 Pulp sprayer H.1 Stove with 4 burners, moulds and deckles, blotters, felt sheets, plastic sinks or large vats, paper towel dispensers needed I. Paper press

286

-

UNT CVAD Program Report


4.6.4 DESIGN: FIBERS PAPERMAKING STUDIO ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

287


4.6.4 DESIGN: FIBERS SCREEN PRINTING SURFACE DESIGN STUDIO ROOM DETAIL SHEET

Room Detail Sheet : Fibers Screen Printing Surface Design Studio

University of North Texas SPACE REQUIREMENTS ROOM QUANTITY: 2 College of Visual Arts + Design ASSIGNABLE SQ. FOOTAGE: 1500 ROOM DIMENSIONS: 30’ x 50’ NUMBER OF OCCUPANTS: 17-20 UTILIZATION (hours/day and general time of day): 8am to 8pm, M-Th, Fridays

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Color rendering fixtures POWER (qty & type): 120Vx10 outlets, 220Vx3 outlets, ceiling system with hanging outlets for hair dryers for students to dry their fabrics EMERGENCY POWER (yes / no, qty.): No

IS ROOM SHARED WITH OTHERS? (list group(s)): No

DATA (qty & type): Provide Category 6A cable to support Audio Visual systems and Wireless connectivity.

RESOURCES SHARED WITH OTHERS: No

VOICE (qty & type): No

ADJACENCIES (internal & external): Next to each other with a double door separating the two surface design rooms

AUDIOVISUAL (qty & type): Dual wide aspect ratio projection screens with high definition projectors. Simple, intuitive control system. High quality audio system with listen assist. Digital video and audio inputs at Instructor location. Web camera and room microphone for Skype sessions.

WINDOWS / NATURAL LIGHT: Yes ACOUSTICS: No SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: Stained concrete, non-slip with drainage floor Base: Walls: Ceiling:

PIPED SERVICES: 1 Stove with 4 burners (3’), 1 Dryer (2’-3”), 1 Washer (2’-3”) WATER / FLOOR DRAIN: 1 Stainless steel sink (9’), 2 Stainless steel sink (4’-3”) 1 Stainless steel sink (10’) TEMPERATURE: Standard HUMIDITY: Humidity control required to maintain paper backed fabric VENTILATION: Built-in for chemicals. Built in vent hood.

MIN. CEILING HEIGHT: Standard

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type):N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): A. 3 Print tables 61” x 192” B. 2 Print tables 42” x 60” C. 1 print table 46” x 73” D. 1 print table 54” x 192” E. 1 Stove with four burners and 220 cord F. 2 Stainless steel counters G. 1 Vertical steamer H. 1 Horizontal steamer I. Stainless steel double sink J. Large Markerboard K. Critique wall with eight 4’ x 8’ homasote L. Metal Shelving M. Metal storage cabinet N. Shelving to store 20 silk painting frames O. Shelving unit for silk screens

288

AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: • Rectangular configuration preferred • Include six clotheslines for drying fabric • Lockers to be built in/placed under tables • Anti-fatigue mats to be placed around tables

-

UNT CVAD Program Report


4.6.4 DESIGN: FIBERS SCREEN PRINTING SURFACE DESIGN STUDIO ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

289


4.6.4 DESIGN: FIBERS SURFACE DESIGN STUDIO WITH WASHOUT BOOTH ROOM DETAIL SHEET

Room Detail Sheet : Fibers Surface Design Studio with Washout Booth

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 1500 ROOM DIMENSIONS: 30’ x 50’ NUMBER OF OCCUPANTS: 17-20 UTILIZATION (hours/day and general time of day): 8am to 8pm, M-Th, Fridays

IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Next to each other with a double door separating the two surface design rooms WINDOWS / NATURAL LIGHT: Yes ACOUSTICS: No SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: Stained concrete, non-slip with drainage floor Base: Walls: Ceiling:

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Color rendering fixtures POWER (qty & type): 120v x 10 outlets, 220v x 3 outlets, ceiling system with hanging outlets (5) for hair dryers for students to dry their fabrics, (5) hanging extension cords EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Provide Category 6A cable to support Audio Visual systems. VOICE (qty & type): No AUDIOVISUAL (qty & type): Dual wide aspect ratio projection screens with high definition projectors. Simple, intuitive control system. High quality audio system with listen assist. Digital video and audio inputs at Instructor location. Web camera and room microphone for Skype sessions. PIPED SERVICES: 1 Stove with 4 burners (3’), 1 Dryer (2’-3”), 1 Washer (2’-3”) WATER / FLOOR DRAIN: 1 Stainless steel sink (9’), 2 Stainless steel sink (4’-3”) 1 Stainless steel sink (10’), 1 Washout booth. Stainless steel sinks to have washout spray faucet TEMPERATURE: Standard HUMIDITY: Humidity control required to maintain paper backed fabric

MIN. CEILING HEIGHT: Standard

VENTILATION: Built-in for vapors AIR CHANGES: Standard

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): A. 2 Light tables, 59” x 39” B. 1 Print table 59” x 121” C. 1 Print table 48” x 120” D. 1 Print table 48” x 148” E. 2 Print tables 54” x 192” F. Washer and dryer G. 1 Stove with 4 burners and 220 cord H. 1 Vertical steamer I. Horizontal steamer J. Stainless steel counter K. 2 Double stainless steel sinks with 2 faucets L. 1 Large markerboard 290

HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: • Rectangular configuration preferred, • Anti fatigue mats to be placed around tables. • Paper tower dispensers required near sinks M. Critique wall with eight sheets of 4’ x 8’ homasote N. Refrigerator O. 1 Washout booth with hose P. 1 Washout booth with power washer Q. Steel shelving unit to store large portable print tables R. Metal shelving S. Heat Press T. Free-hand mixer U. Paper press V. Lockers W. Shelving unit for silk screens -

UNT CVAD Program Report


4.6.4 DESIGN: FIBERS SURFACE DESIGN STUDIO WITH WASHOUT BOOTH ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

291


4.6.4 DESIGN: FIBERS WASHOUT BOOTH ROOM DETAIL SHEET

Room Detail Sheet : Fibers Washout Booth

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 300 ROOM DIMENSIONS: 15’ x 20’ NUMBER OF OCCUPANTS: 17-20 UTILIZATION (hours/day and general time of day): 8am to 8pm, M-Th, Fridays

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard POWER (qty & type): 120v x 3 outlets EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): No

IS ROOM SHARED WITH OTHERS? (list group(s)): No

VOICE (qty & type): No

RESOURCES SHARED WITH OTHERS: No

AUDIOVISUAL (qty & type): No

ADJACENCIES (internal & external): Access through one of the surface design rooms

PIPED SERVICES: No

WINDOWS / NATURAL LIGHT: No ACOUSTICS: No SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Water-proof Floor: Stained concrete, non-slip with drainage floor Base: Walls: Ceiling:

WATER / FLOOR DRAIN: 3 washout booths TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: Rectangular configuration preferred, Stand alone room required due to over-spray,

MIN. CEILING HEIGHT: Standard

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): A. 2 washout booths B.1 exposure unit, paper towel dispensers needed

292

-

UNT CVAD Program Report


4.6.4 DESIGN: FIBERS WASHOUT BOOTH ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

293


4.6.4 DESIGN: FIBERS DARKROOM ROOM DETAIL SHEET

Room Detail Sheet : Fibers Darkroom

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 300 ROOM DIMENSIONS: 15’ x 20’ NUMBER OF OCCUPANTS: 17-20

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Safe lights POWER (qty & type): 120v x 3 outlets EMERGENCY POWER (yes / no, qty.): No

UTILIZATION (hours/day and general time of day): 8am to 8pm, M-Th, Fridays

DATA (qty & type): No

IS ROOM SHARED WITH OTHERS? (list group(s)): No

VOICE (qty & type): No

RESOURCES SHARED WITH OTHERS: No

AUDIOVISUAL (qty & type): No

ADJACENCIES (internal & external): Access through exposure unit room

PIPED SERVICES: No

WINDOWS / NATURAL LIGHT: No ACOUSTICS: No SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: Stained concrete Base: Walls: Ceiling:

WATER / FLOOR DRAIN: Stainless steel sink TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Built-in for vapors AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: Square or rectangular configuration preferred, paper towel dispensers needed

MIN. CEILING HEIGHT: Standard

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): A. Counter with sink and cabinet underneath B.10 shelves for drying screens FURNITURE (qty & type): Standard

294

-

UNT CVAD Program Report


4.6.4 DESIGN: FIBERS DARK ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

295


4.6.4 DESIGN: FIBERS EXPOSURE UNIT ROOM ROOM DETAIL SHEET

Room Detail Sheet : Fibers Exposure Unit Room

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 200 300 ROOM DIMENSIONS: Minimum 10’ x 20’ (15’ x 20’) NUMBER OF OCCUPANTS: 17-20 UTILIZATION (hours/day and general time of day): 8am to 8pm, M-Th, Fridays

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Semi-safe lights POWER (qty & type): 120v x 3 outlets EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): No

IS ROOM SHARED WITH OTHERS? (list group(s)): No

VOICE (qty & type): No

RESOURCES SHARED WITH OTHERS: No

AUDIOVISUAL (qty & type): No

ADJACENCIES (internal & external): Next to washout booths

PIPED SERVICES: No

WINDOWS / NATURAL LIGHT: No

WATER / FLOOR DRAIN: Stainless steel sink

ACOUSTICS: No

TEMPERATURE: Standard

SIGHTLINES: No

HUMIDITY: Standard

MIN. DOOR WIDTH & DESCRIPTION: Standard

VENTILATION: Built-in for vapors

ROOM FINISHES: Standard U.N.O. Floor: Stained concrete Base: Walls: Ceiling:

AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: • Rectangular configuration preferred

MIN. CEILING HEIGHT: Standard

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): C. Stainless steel countertop FURNITURE (qty & type): Standard A. 1 large exposure unit (7’-9”wide x 6’ tall when opened x 4’-7” deep), paper towel dispensers needed B. Worktable

296

-

UNT CVAD Program Report


4.6.4 DESIGN: FIBERS EXPOSURE UNIT ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

297


4.6.4 DESIGN: FIBERS CHEMICAL ROOM ROOM DETAIL SHEET

Room Detail Sheet : Fibers Chemical Room

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 300 ROOM DIMENSIONS: 15’ x 20’ NUMBER OF OCCUPANTS: 19-24

UTILIZATION (hours/day and general time of day): Standard IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Surface design rooms WINDOWS / NATURAL LIGHT: No ACOUSTICS: No SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Double Doors, 42” width min. ROOM FINISHES: Standard U.N.O. Floor: Sealed concrete Base: Walls: Ceiling: MIN. CEILING HEIGHT: 10’

FURNITURE, FIXTURES & EQUIPMENT

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard POWER (qty & type): Standard EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): No VOICE (qty & type): No AUDIOVISUAL (qty & type): No PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: Hazardous chemical cabinet, boxes of chemicals and supplies, 5 gallon buckets of chemicals SPECIAL REQUIREMENTS / NOTES: • Chemical room is used to supply chemicals for all fibers classes and store equipment for the Surface Design studio and other indicated classes. It is also a room layout used to store projects for classes taught by teaching fellows and adjuncts.

MOBILE (qty & type): A.1 Dolly

BUILT-IN (qty & type): B.1 Deep built-in shelf, built-in dowel rods for storing fabric FURNITURE (qty & type): C. 2 Metal shelving units D.1 metal Chemical storage cabinet E. Metal Cabinet F. Box for chemical supplies G. 5 gallon buckets (of various chemicals)

298

-

UNT CVAD Program Report


4.6.4 DESIGN: FIBERS CHEMICAL ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

299


4.6.4 DESIGN: FIBERS WARPING ROOM ROOM DETAIL SHEET

Room Detail Sheet : Fibers Warping Room

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 500 600 ROOM DIMENSIONS: 20’ x 25’ (20’ x 30’) NUMBER OF OCCUPANTS: 17-20 UTILIZATION (hours/day and general time of day): 8am to 8pm, M-Th, Fridays

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Color rendering fixtures POWER (qty & type): 120v x 18 outlets EMERGENCY POWER (yes / no, qty.): No DATA (qty & type); No

IS ROOM SHARED WITH OTHERS? (list group(s)): No

VOICE (qty & type): No

RESOURCES SHARED WITH OTHERS: No

AUDIOVISUAL (qty & type): No

ADJACENCIES (internal & external): Weaving I and Advanced Weaving

PIPED SERVICES: No

WINDOWS / NATURAL LIGHT: Yes ACOUSTICS: Sound dampening SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Double doors, 42” wide min. ROOM FINISHES: Standard U.N.O. Floor: Stained concrete Base: Walls: Ceiling:

WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Dry VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No

SPECIAL REQUIREMENTS / NOTES:

MIN. CEILING HEIGHT: Standard

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): A. Space for18 Warping boards B. 2 Floor looms (Rectangular configuration preferred) C. Light tables

300

-

UNT CVAD Program Report


4.6.4 DESIGN: FIBERS WARPING ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

301


4.6.4 DESIGN: FIBERS RESOURCE ROOM ROOM DETAIL SHEET

Room Detail Sheet : Fibers Resource Room

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 300 ROOM DIMENSIONS: 10’ x 30’ (20’ x 15’) NUMBER OF OCCUPANTS: 19-24

UTILIZATION (hours/day and general time of day): Standard

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard POWER (qty & type): Standard EMERGENCY POWER (yes / no, qty.): No

IS ROOM SHARED WITH OTHERS? (list group(s)): No

DATA (qty & type): Provide Category 6A cable to support Wireless connectivity.

RESOURCES SHARED WITH OTHERS: No

VOICE (qty & type): No

ADJACENCIES (internal & external): Surface design rooms

AUDIOVISUAL (qty & type): No

WINDOWS / NATURAL LIGHT: No

PIPED SERVICES: No

ACOUSTICS: No

WATER / FLOOR DRAIN: No

SIGHTLINES: No

TEMPERATURE: Standard

MIN. DOOR WIDTH & DESCRIPTION: Standard

HUMIDITY: Standard

ROOM FINISHES: Standard Floor: Base: Walls: Ceiling:

VENTILATION: Standard

MIN. CEILING HEIGHT: 10’

AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES:

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): Bookshelves FURNITURE (qty & type): Worktable

302

-

UNT CVAD Program Report


4.6.4 DESIGN: FIBERS RESOURCE ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

303


4.6.4 DESIGN: FIBERS ADVANCED WEAVING AND KNITTING SUPPLY CLOSET ROOM DETAIL SHEET

Room Detail Sheet : Fibers Advanced Weaving and Knitting Supply Closet

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 200 300 ROOM DIMENSIONS: 10’ x 20’ 15’ x 20’ NUMBER OF OCCUPANTS: 17-20

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Color rendering fixtures POWER (qty & type): 120v x 4 outlets EMERGENCY POWER (yes / no, qty.): No

UTILIZATION (hours/day and general time of day): 8am to 8pm, M-Th, Fridays

DATA (qty & type): Wifi

IS ROOM SHARED WITH OTHERS? (list group(s)): No

VOICE (qty & type): No

RESOURCES SHARED WITH OTHERS: No

AUDIOVISUAL (qty & type): No

ADJACENCIES (internal & external): Located next to or within advanced weaving studio

PIPED SERVICES: No

WINDOWS / NATURAL LIGHT: Yes ACOUSTICS: No SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: Stained concrete Base: Walls: Ceiling:

WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Dry VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: Yes SPECIAL REQUIREMENTS / NOTES: Square or rectangular configuration preferred

MIN. CEILING HEIGHT: Standard

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type):

BUILT-IN (qty & type): A. Storage for excess reeds B. Storage for specialty yarns, storage for odds and ends, 20 tubs, 3 ladders FURNITURE (qty & type): C. 3 Metal shelves D. 2 Loom benches E. 1 Print table F. Hazardous material storage

304

-

UNT CVAD Program Report


4.6.4 DESIGN: FIBERS ADVANCED WEAVING AND KNITTING SUPPLY CLOSET ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

305



4.6.5 Industrial Design

The University of North Texas

The Industrial Design program is a new addition to the UNT curriculum. The start of this program would coincide with the opening of the New CVAD Building. This program will focus on small products, retail applications and exhibit design, driven by the regional industry base. All disciplines could potentially have involvement with the program. A sense of community with all design disciplines and cross connection of all areas is important. Centrally located and in close proximity to Sculpture and Metals would be ideal as they may share outdoor shop space. Additional program information is located in the following Room Detail Sheets, Room Layouts and the Space Program List.


4.6.5 DESIGN INDUSTRIAL DESIGN PROGRAM ADJACENCY DIAGRAM

308

-

UNT CVAD Program Report


4.6.5 DESIGN INDUSTRIAL DESIGN VISUAL PROGRAM

-

UNT CVAD Program Report

309


4.6.5 DESIGN INDUSTRIAL DESIGN SPACE PROGRAM Space Name Position

Circulation Factor

Room Number

2013

2016

Number Assignable of Spaces S/F

Number Unit Area of Spaces

Total Area

Industrial Design Faculty Offices Faculty Growth

N/A

0

0

7

130

910

Classrooms Class/Lab/Studio

N/A

0

0

6

1500

9000

Studios Graduate Studios

N/A

0

0

7

300

2100

Shops Wood Shop Shop

N/A N/A

0 0

0 0

1 1

1500 2500

1500 2500

Outdoor Spaces Shop

N/A

0

0

1

2500

0

Support Spaces Critique Room Storage Room

N/A N/A

0 0

0 0

2 1

900 1200

1800 1200

Total Spaces Assignable Square Feet Net to Gross @ 45% = Assignable SF x (1/(1-45%))= Department Gross SF

310

0 0.8181

26 0 0

19,010 15,552

0

34,562

-

UNT CVAD Program Report


Arvin Abadailla


4.6.5 DESIGN: INDUSTRIAL CLASS / LAB / STUDIO ROOM DETAIL SHEET

Room Detail Sheet : Industrial Design Class / Lab / Studio

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 6 ASSIGNABLE SQ. FOOTAGE: 1500 x 6 = 9000 ROOM DIMENSIONS: 30’ x 50’

NUMBER OF OCCUPANTS: 20-40 (20-40 students, 1 instructor, 1 grad student observing) UTILIZATION (hours/day and general time of day): Monday – Friday 8-6, may be used by students after hours IS ROOM SHARED WITH OTHERS? (list group(s)): New Media, Industrial, If large enough, could be shared with other design departments RESOURCES SHARED WITH OTHERS: No

BUILDING SYSTEM REQUIREMENTS SECURITY: 24hour swipe card access TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): adjustability, dimmable fixtures with track lighting along side walls above pinup space, Fluorescent POWER (qty & type): floor cores for training tables, power at front of room for instructor computer and projection screen, power along walls and in floor cores for max flexibility, enough for 60 people to plug in EMERGENCY POWER (yes / no, qty.): No DATA (qty & type); data in floor cores and at front of room for instructor computer. Wireless network connection, as well as Ethernet network access at a presentation desk. VOICE (qty & type): N/A

ADJACENCIES (internal & external): Communication Design, New Media, Industrial Classrooms, Sculpture Classrooms, Resource Room, Storage Room, Spray room, Cleanuproom/dark closet. each studio space has a shop adjacent to it

AUDIOVISUAL (qty & type): projection screen with high definition projector

WINDOWS / NATURAL LIGHT: Yes, with control for demo/presentations,

WATER / FLOOR DRAIN: No

ACOUSTICS: Sound dampening SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: 48” ROOM FINISHES: Standard U.N.O. Floor: concrete Base: Walls: paint, pinup material on side walls, marker board on front wall

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): (A) Training tables with tilt able top to seat 14 total with power at work surface; (B) 28 training chairs, (C) 2 Mobile marker boards in lieu of permanent wall mounted boards BUILT-IN (qty & type): Millwork: Sink with counter space and lockable cabinet storage. Lockers for students FURNITURE (qty & type): (E) Task stool, Analog Clocks on wall x2 (F) 30x60 standing height desk at front of room (G) 4 flat files to store work (H.) Projection screen ( I.) whiteboards along front of room ( J.) Computer tables and chairs x 20 (K) training chair, (L) 5-10 Cutting board tables, (M) 5-10 light tables, (N) instructor station that can be moved around

312

PIPED SERVICES: Sink

TEMPERATURE: controllable, no need for individual control, just want to have consistency, 65-80 Standard HUMIDITY: low to medium, Dry VENTILATION: In some rooms, too cold, others too hot / yes AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: Fire cabinet SPECIAL REQUIREMENTS / NOTES: Standardize the classrooms to suit needs of any subjects/sections; flexibility to rearrange setup each day. Space for students to pinup work on walls then stand back far enough to accurately review and critique. Sink used for cleanup when using messy materials. Training tables need to be wide enough for each student to lay out work and laptop. Instructor computer setup at back of room so can view students. Instructor uses laptop. Need setup at desk, display in hallways Open work space for students to work when classrooms are in use. Space would also be used for larger workshops/demos that might combine class sections or weekend workshops. Flexibility in room so could also be turned into seminar room -All work surfaces should have self healing mat EQUIPMENT (qty & type): CNC 3D Printer 3D Scanner UV Printer Plasma Cutter Laser Cutter -

UNT CVAD Program Report


4.6.5 DESIGN: INDUSTRIAL CLASS / LAB / STUDIO ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

313


4.6.5 DESIGN: INDUSTRIAL WOOD SHOP ROOM DETAIL SHEET Room Detail Sheet : Industrial Design Wood Shop

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 1500 ROOM DIMENSIONS: 30’ x 50’ NUMBER OF OCCUPANTS: 25 UTILIZATION (hours/day and general time of day): 14 hrs M-F 8am-11pm

BUILDING SYSTEM REQUIREMENTS SECURITY: Key locked door TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Track lighting and fluorescent POWER (qty & type): 120v x 16 outlets, 220v x 6 outlets EMERGENCY POWER (yes / no, qty.): No

RESOURCES SHARED WITH OTHERS: Yes

DATA (qty & type); Wireless, and 10 cat 5 plugs. Provide Category 6A cable from the Telecom room to support ten workstations. Provide wireless network coverage this area. Ensure all wireless devices are located in a ceiling or wall enclosure. Provide Power over Ethernet for wireless devices.

ADJACENCIES (internal & external): Sculpture Courtyard shop

VOICE (qty & type): No

WINDOWS / NATURAL LIGHT: Yes

AUDIOVISUAL (qty & type): No

ACOUSTICS: Sound dampening

PIPED SERVICES: Pneumatic compressed air 6 hookups

SIGHTLINES: No

WATER / FLOOR DRAIN: Shop sink with trap and floor drain. Hot and cold water

IS ROOM SHARED WITH OTHERS? (list group(s)): Yes

MIN. DOOR WIDTH & DESCRIPTION: 72” double door

TEMPERATURE: 65-70

ROOM FINISHES: Standard U.N.O. Floor: sealed concrete Base: flush wall to floor Walls: plywood backed sheetrock Ceiling: no drop, exposed utilities, hanging points in a 4’ grid 200 lbs min

AIR CHANGES: Standard

MIN. CEILING HEIGHT: 12’

HAZARDOUS MATERIALS & STORAGE METHOD: Fire cabinet

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): Shop Tables x6 BUILT-IN (qty & type): N/A

HUMIDITY: Museum dry VENTILATION: Yes

SPECIAL REQUIREMENTS / NOTES: Needs to be a separate entity from Sculpture Shop accessible by all departments

FURNITURE (qty & type): chairs and stools x 25 Match the Sculpture Wood Shop FURNITURE (qty & type): Sawstop 10” Table Saw Stephen Bader Sander Dewalt 12” Miter/Radial Arm Saw Delta combo 12”disc/6” belt sander Powermatic 16” Planer Delta Hollow Chisel Mortiser Dewalt 10” Miter Saw Powermatic Variable speed Drill Press Rockwell 8” Jointer Rockwell 10” Table Saw/Router Table Delta 12” Radial Arm Saw Grizzly Spindle Sander Delta 42” Wood Lathe General International Scroll Saw Powermatic Edge Sander Rikon 24” Lathe Ryobi Bench Grinder Crescent 36” Band Saw

314

-

UNT CVAD Program Report


4.6.5 DESIGN: INDUSTRIAL WOOD SHOP ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

315


4.6.5 DESIGN: INDUSTRIAL DESIGN SHOP ROOM DETAIL SHEET

Room Detail Sheet : Industrial Design Shop

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 2500 ROOM DIMENSIONS: 50’ x 50’ NUMBER OF OCCUPANTS: 25 UTILIZATION (hours/day and general time of day): 14 hrs M-F 8am-11pm

IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No

BUILDING SYSTEM REQUIREMENTS SECURITY: Key locked door TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Track lighting and fluorescent POWER (qty & type): 120v x 16 outlets , 220v x 6 outlets EMERGENCY POWER (yes / no, qty.): No DATA (qty & type); Wireless, and 10 cat 5 plugs. Provide Category 6A cable from the Telecom room to support ten workstations. Provide wireless network coverage this area. Ensure all wireless devices are located in a ceiling or wall enclosure. Provide Power over Ethernet for wireless devices.

ADJACENCIES (internal & external): Shop – Hub and Spoke to Metals, New Media, Industrial, Paint Sculpture faculty offices close to shop to answer student questions

VOICE (qty & type): No

WINDOWS / NATURAL LIGHT: Prefer outdoor covered courtyard

PIPED SERVICES: Pneumatic compressed air 6 hookups

AUDIOVISUAL (qty & type): No

ACOUSTICS: Sound dampening

WATER / FLOOR DRAIN: Shop sink with trap and floor drain. Hot and cold water

SIGHTLINES: No

TEMPERATURE: 65-70

MIN. DOOR WIDTH & DESCRIPTION: 72” double door Fork-lift required

HUMIDITY: Museum dry

ROOM FINISHES: Standard U.N.O. Floor: sealed concrete Base: flush wall to floor Walls: plywood backed sheetrock Ceiling: no drop, exposed utilities, hanging points in a 4ft grid 200 lbs min MIN. CEILING HEIGHT: 12’

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): Shop Tables x6

VENTILATION: Yes AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: Fire cabinet SPECIAL REQUIREMENTS / NOTES: • Required area for Spray Booth • Required area for Welding • Required area for Foundry • Required area for tool check-out “The Bar”

BUILT-IN (qty & type): N/A FURNITURE (qty & type): chairs and stools x 25 Match the Sculpture Courtyard Shop

316

-

UNT CVAD Program Report


4.6.5 DESIGN: INDUSTRIAL DESIGN SHOP ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

317


4.6.5 DESIGN: INDUSTRIAL DESIGN CRITIQUE ROOM DETAIL SHEET

Room Detail Sheet: Industrial Design Critique

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 2 ASSIGNABLE SQ. FOOTAGE: 900 ROOM DIMENSIONS: 30’ x 30’ (with divider wall) NUMBER OF OCCUPANTS: 25 UTILIZATION (hours/day and general time of day): 14 hrs M-F 8am-11pm

BUILDING SYSTEM REQUIREMENTS SECURITY: Key locked door TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Track lighting and fluorescent POWER (qty & type): 120v quad outlets four per full wall EMERGENCY POWER (yes / no, qty.): No

ADJACENCIES (internal & external): Classroom

DATA (qty & type); Wireless, and 2 cat 5 plugs. Provide Category 6A cable from the Telecom room to support two network connections. Provide wireless network coverage this area. Ensure all wireless devices are located in a ceiling or wall enclosure. Provide Power over Ethernet for wireless devices. Provide Category 6A cable from the Telecom room to support AV systems.

WINDOWS / NATURAL LIGHT: Yes, with blackout shades

VOICE (qty & type): No

ACOUSTICS: Sound dampening

AUDIOVISUAL (qty & type): Dual wide aspect ratio projection screens with high definition projectors. Simple, intuitive control system. High quality audio system with listen assist. Digital video and audio inputs at Instructor location. Web camera and room microphone for Skype sessions.

IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No

SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: 72” double door ROOM FINISHES: Standard U.N.O. Floor: Sealed concrete Base: flush wall to floor Walls: plywood backed sheetrock Ceiling: no drop, exposed utilities, hanging points in a 4ft grid 200 lbs min MIN. CEILING HEIGHT: 12’

FURNITURE, FIXTURES & EQUIPMENT

PIPED SERVICES: Pneumatic compressed air on one wall WATER / FLOOR DRAIN: No TEMPERATURE: 65-70 HUMIDITY: Museum dry VENTILATION: No

MOBILE (qty & type): N/A

AIR CHANGES: Standard

BUILT-IN (qty & type): N/A

HAZARDOUS MATERIALS & STORAGE METHOD: No

FURNITURE (qty & type): Standard

SPECIAL REQUIREMENTS / NOTES: Courtyard critique space ideal

NOT TO SCALE 318

-

UNT CVAD Program Report


4.6.5 DESIGN: INDUSTRIAL DESIGN CRITIQUE ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

319


4.6.5 DESIGN: INDUSTRIAL STORAGE ROOM ROOM DETAIL SHEET

Room Detail Sheet : Industrial Design Storage Room

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 1200 ROOM DIMENSIONS: 30’ x 40’ NUMBER OF OCCUPANTS: 18-24 Projects

UTILIZATION (hours/day and general time of day): 8am to 8pm, M-Th, Fridays and until close of building used for open time

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): task(floodlights on walls), Overhead, Color advanced fluorescents POWER (qty & type): Enough for portable lights and heaters EMERGENCY POWER (yes / no, qty.): No

IS ROOM SHARED WITH OTHERS? (list group(s)): No

DATA (qty & type); Provide Category 6A cable from Telecom room to support AV systems. Provide wireless network coverage this area. Ensure all wireless devices are located in a ceiling or wall enclosure. Provide Power over Ethernet for wireless devices.

RESOURCES SHARED WITH OTHERS: No

VOICE (qty & type): No

ADJACENCIES (internal & external): Painting and Drawing classrooms

AUDIOVISUAL (qty & type): Digital video and audio inputs at room computer and terminated at display location. Backing to support large flat panel display. Web camera and room microphone for Skype sessions.

WINDOWS / NATURAL LIGHT: No ACOUSTICS: No SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: 8’ double doors ROOM FINISHES: Standard U.N.O. Floor: Easily cleanable Base: Walls: Drywall over plywood so that work can be pinned or nailed to it Ceiling: MIN. CEILING HEIGHT: 12’, 8ft min

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A

PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: No VENTILATION: Adequate ventilation for solvent-based paints, must be quiet AIR CHANGES: Adequate for use with solvent-based paints HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: Require 1/3 of room for student project storage racks Hallways used for student work display

FURNITURE (qty & type): Drying racks

320

-

UNT CVAD Program Report


4.6.5 DESIGN: INDUSTRIAL STORAGE ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

321



4.6.6 Interior Design

The University of North Texas

The following information pertains to the Interior Design program. The philosophy of this program is to prepare the students for the Interior Design profession. This is a studio driven program and portfolios are important. It is preferable to locate the entire program within one building. Flexible space and furniture is important to encourage multiple uses of the spaces. This discipline would like to feel a sense of community within the program as well as other disciplines. Additional program information is located in the following Room Detail Sheets, Room Layouts and the Space Program List.


4.6.6 DESIGN INTERIOR DESIGN PROGRAM ADJACENCY DIAGRAM

324

-

UNT CVAD Program Report


4.6.6 DESIGN INTERIOR DESIGN VISUAL PROGRAM

-

UNT CVAD Program Report

325


4.6.6 DESIGN INTERIOR DESIGN SPACE PROGRAM Space Name Position

Circulation Factor

Room Number

2013

2016

Number Assignable of Spaces S/F

Number Unit Area Total Area of Spaces

Interior Design Faculty Offices Professor - Johnnie Stark Professor - Bruce Nacke Professor - Phillip Park Professor - Open Faculty Growth - Professor/Adjunct

Art 205 Art 204 Art 206 Art 237 N/A

1 1 1 1 0

178 178 178 178 0

1 1 1 1 2

130 130 130 130 65

130 130 130 130 130

Classrooms Class/Lab/Studio

Art 238

1

722

5

1500

7500

Studios Graduate Studio Design Studio

Art 241 Art 242

1 1

1063 1054

2 0

300 0

600 0

Art 240

1

549

1

300

300

Art 240A Art 240A Art 201

1 1 1

115 115 179

1 1 1

400 200 300

400 200 300

Labs Critique/Lighting Lab Support Spaces Storage Room Copy Room Resource Room Total Spaces Assignable Square Feet Net to Gross @ 45% = Assignable SF x (1/(1-45%))= Department Gross SF

326

11 0.8181

17 4,509 3,689

9,950 8,140

8,198

18,090

-

UNT CVAD Program Report


Rosena MacFadzean


4.6.6 DESIGN: INTERIOR DESIGN CLASS / LAB /STUDIO ROOM DETAIL SHEET

Room Detail Sheet: Interior Design Class / Lab / Studio

University of North Texas SPACE REQUIREMENTS ROOM QUANTITY: 5 College of Visual Arts + Design

ASSIGNABLE SQ. FOOTAGE: 1063 (1500) ROOM DIMENSIONS: 29’4” x 36’4” (30’ x 50’) NUMBER OF OCCUPANTS: 20 students; 1 instructor UTILIZATION (hours/day and general time of day): ADES 3630 T/Th Fall 12 hrs/wk ADES 3640 T/Th Spr 12 hrs/wk ADES 4615 T/Th 3 hrs/wk (room assignment varies according to class size) M-F; after 6:00 p.m., used for student meetings and study hall (times vary) ADES 2630 M/W Fall 18-24 hrs/wk ADES 3610 T/Th Fall 12 hrs/wk ADES 4640 T/Th Spr 12 hrs/wk M-F after classes, used for student meetings and study hall (times vary) IS ROOM SHARED WITH OTHERS? (list group(s)): M-F ID & Comm Design students use for study; all students in Design programs need a dedicated space to work outside of class

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable doors to corridor and adjacent studio Lockable doors to corridor and adjacent studio (AB 242 can be sequestered from AB 241) TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): 2’ x 4’ Fluorescent w/ motion sensor; zone switching; 10 ceilingmounted adjustable track fixtures @ display wall POWER (qty & type): 1 available duplex outlet; 2 wall-mounted plug strips @ 36” aff, w/ 20 single outlets ea. EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Internet access; Wi-Fi (see AV) VOICE (qty & type): No AUDIOVISUAL (qty & type): UNT standard hardwired console & overhead projector, screen, speakers PIPED SERVICES: No

RESOURCES SHARED WITH OTHERS: No

WATER / FLOOR DRAIN: No

ADJACENCIES (internal & external): Proximity to other ID studios, faculty offices, computer lab and Departmental resources

TEMPERATURE: Standard

WINDOWS / NATURAL LIGHT: With blackout shades ACOUSTICS: Adequate for class instruction SIGHTLINES: Instructor to entry MIN. DOOR WIDTH & DESCRIPTION: 1 @ 36” w to corridor; 1 @ 36”w to adjacent studio or open to breakout space (see Comments) ROOM FINISHES: Standard U.N.O. Floor: Sealed concrete, VAT (note: floor tile was abated during remodel of 240 & 241; sealed concrete referable Base: Rubber Walls: Brick exterior wall; white board & painted gyp used as tackable surface; homasote desired, available to each student. painted gyp w/display rails Ceiling: 2’ x 4’ Lay-in acoustical tile

HUMIDITY: Standard VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: Students require data/electrical capability to work on their laptops during class; existing Wi-Fi service is not dependable

MIN. CEILING HEIGHT: 12’

FURNITURE, FIXTURES & EQUIPMENT

MOBILE (qty & type): G. 20 Individual lockable tabourets desired H. AV carts (varies) BUILT-IN (qty & type): Work/layout space FURNITURE (qty & type): A. 20 Adjustable drafting tables (style varies) 328 B.1 Drafting table for instructor C. 20 Adjustable drafting stools

-

UNT CVAD Program Report


4.6.6 DESIGN: INTERIOR DESIGN CLASS / LAB /STUDIO ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

329


4.6.6 DESIGN: INTERIOR DESIGN CRITIQUE / LIGHTING LAB ROOM DETAIL SHEET

Room Detail Sheet : Interior Design Critique / Lighting Lab

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 900 ROOM DIMENSIONS: 30’ x 30’ NUMBER OF OCCUPANTS: 19-24

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard overhead fluorescent POWER (qty & type): 110V x 5 outlets EMERGENCY POWER (yes / no, qty.): No

UTILIZATION (hours/day and general time of day): M-F, 8-10 hr/day; 8:00a.m. – 6:00 p.m.

DATA (qty & type); No

IS ROOM SHARED WITH OTHERS? (list group(s)): No

VOICE (qty & type): No

RESOURCES SHARED WITH OTHERS: No

AUDIOVISUAL (qty & type): No

ADJACENCIES (internal & external): Studio classrooms

PIPED SERVICES: No

WINDOWS / NATURAL LIGHT: Yes

WATER / FLOOR DRAIN: No

ACOUSTICS: Sound dampening

TEMPERATURE: Standard

SIGHTLINES: No

HUMIDITY: Standard

MIN. DOOR WIDTH & DESCRIPTION: Standard

VENTILATION: Standard

ROOM FINISHES: Standard U.N.O. Floor: Sealed concrete Base: Walls: Ceiling:

AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES:

MIN. CEILING HEIGHT: 10’

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): 25 Chairs

330

-

UNT CVAD Program Report


4.6.6 DESIGN: INTERIOR DESIGN CRITIQUE / LIGHTING LAB ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

331


4.6.6 DESIGN: INTERIOR DESIGN STORAGE ROOM DETAIL SHEET

Room Detail Sheet : Interior Design Storage

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 400 ROOM DIMENSIONS: 20’ x 20’ NUMBER OF OCCUPANTS: 6-8 UTILIZATION (hours/day and general time of day): Storage

BUILDING SYSTEM REQUIREMENTS SECURITY: Keyed with Department Office TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Standard overhead fluorescent POWER (qty & type): Standard EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): No

IS ROOM SHARED WITH OTHERS? (list group(s)): No

VOICE (qty & type): No

RESOURCES SHARED WITH OTHERS: No

AUDIOVISUAL (qty & type): No

ADJACENCIES (internal & external): In department location, adjacent to Administrative Assistant

PIPED SERVICES: No

WINDOWS / NATURAL LIGHT: No ACOUSTICS: Not Critical SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: ADA, Secondary Egress preferred ROOM FINISHES: Standard U.N.O. Floor: Building Standard for all Base: Walls: Ceiling:

WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: We currently have two small closets that are our only storage. We have no long-range storage capabilities. We have carts and other types of storage distributed around the department in classrooms and offices.

MIN. CEILING HEIGHT: 9’

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): A. 3 Rolling seat carts

We must also provide storage for ALL work produced in the ID classes for the two years prior to our CIDA site visit. Must be located near the exhibition locations. In the past we have had to store in other buildings with resulting damage to some of the work.

BUILT-IN (qty & type): B. Flexible shelving to accommodate supplies and long range storage FURNITURE (qty & type): C. Flexible shelving to accommodate supplies and long range storage

332

-

UNT CVAD Program Report


4.6.6 DESIGN: INTERIOR DESIGN STORAGE ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

333


4.6.6 DESIGN: INTERIOR DESIGN COPY ROOM ROOM DETAIL SHEET

Room Detail Sheet: Interior Design Copy Room

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable

ROOM DIMENSIONS: 10’ x 20’

TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): 2’ x 4’ Fluorescents w/ motion sensor; wall-mounted fixtures for “lighting lab” function

NUMBER OF OCCUPANTS: Support space; Variable

POWER (qty & type): 110V x 2 outlets, 210V x 1 outlet for copier

UTILIZATION (hours/day and general time of day): Variable; Open during business hours

EMERGENCY POWER (yes / no, qty.): No

ASSIGNABLE SQ. FOOTAGE: 200

IS ROOM SHARED WITH OTHERS? (list group(s)): Design Department faculty use printer; copier and storage designated for ID student use & instructional support RESOURCES SHARED WITH OTHERS: No

DATA (qty & type): 1 Data outlet for faculty printer. Provide Category 6A cable from the Telecom room to support faculty printing. Provide wireless network coverage this area. Ensure all wireless devices are located in a ceiling or wall enclosure. Provide Power over Ethernet for wireless devices. VOICE (qty & type): No

ADJACENCIES (internal & external): ID faculty, instructional spaces; Departmental office

AUDIOVISUAL (qty & type): No

WINDOWS / NATURAL LIGHT: No

PIPED SERVICES: No

ACOUSTICS: Adequate for support function

WATER / FLOOR DRAIN: No

SIGHTLINES: Difficult to see from corridor

TEMPERATURE: Standard

MIN. DOOR WIDTH & DESCRIPTION: Standard

HUMIDITY: Standard

ROOM FINISHES: Standard U.N.O. Floor: Sealed concrete Base: Rubber Walls: Painted gyp Ceiling: 2’ x 4’ Lay-in acoustical tile

VENTILATION: Standard

MIN. CEILING HEIGHT: 9’

SPECIAL REQUIREMENTS / NOTES:

AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): A. 2 flat files B. Misc storage units C. Copier; printer D. Lightbox

334

-

UNT CVAD Program Report


4.6.6 DESIGN: INTERIOR DESIGN COPY ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

335


4.6.6 DESIGN: INTERIOR DESIGN RESOURCE ROOM ROOM DETAIL SHEET

Room Detail Sheet: Interior Design Resource Room

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: (300) ROOM DIMENSIONS: (15’ X 20’)

NUMBER OF OCCUPANTS: 1 student attendant (see below); students accessing materials (varies) UTILIZATION (hours/day and general time of day): Student attendant monitors the Resource Library 10 hrs/week, MWF; door has ID card access for ID faculty & majors IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: ID faculty & majors only

BUILDING SYSTEM REQUIREMENTS SECURITY: Card access for ID faculty & majors only TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): 2’x 4’ Overhead fluorescents w/ motion sensor; demo fixture “lighting lab” display POWER (qty & type): 110v x 2 outlets EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Provide Category 6A cable from the nearest Telecom Room to support three network connections. Provide Category 6A cable to support Wireless connectivity. VOICE (qty & type): Provide Category 6A cable from the nearest Telecom Room to support one voice connection.

ADJACENCIES (internal & external): Proximity to ID studios/classrooms

AUDIOVISUAL (qty & type): No

WINDOWS / NATURAL LIGHT: No

PIPED SERVICES: No

ACOUSTICS: No

WATER / FLOOR DRAIN: No

SIGHTLINES: Monitor has sightline to students entering room

TEMPERATURE: Standard

MIN. DOOR WIDTH & DESCRIPTION: Standard

HUMIDITY: Standard

ROOM FINISHES: Standard U.N.O. Floor: Direct glue, low pile carpet Base: Rubber Walls: Painted gyp Ceiling: 2’ x 4’ Lay-in acoustical tile

VENTILATION: Standard

MIN. CEILING HEIGHT: 9’

FURNITURE, FIXTURES & EQUIPMENT

AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: Require shared book storage

MOBILE (qty & type): A. Reconfigurable wall mounted shelving system B. Work surfaces C. Storage units D. Bins & carts BUILT-IN (qty & type): See above FURNITURE (qty & type): E. Task chair

336

-

UNT CVAD Program Report


4.6.6 DESIGN: INTERIOR DESIGN RESOURCE ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

337



4.6.7 Texas Fashion Collection

The University of North Texas

The following area makes up the Texas Fashion Collection (TFC) program. The programs future focus is on becoming an American Accredited Art Museum with public visiting hours on weekends and during typical museum hours. Flexible lighting is important, LED lighting does not suit the needs of the collection. The preference is to be on the same floor as Fashion Design but not necessarily directly adjacent. Humidity and temperature control is crucial. Additional specific program requirements can be found in the following Room Detail Sheets, Room Layouts, and the Space Program List.


4.6.7 DESIGN TEXAS FASHION COLLECTION PROGRAM ADJACENCY DIAGRAM

340

-

UNT CVAD Program Report


4.6.7 DESIGN TEXAS FASHION COLLECTION VISUAL PROGRAM

-

UNT CVAD Program Report

341


4.6.7 DESIGN TEXAS FASHION COLLECTION SPACE PROGRAM Space Name Position

Circulation Factor

Room Number

2013

2016

Number Assignable of Spaces S/F

Number Unit Area of Spaces

Total Area

TFC Faculty Offices Prof. and TFC Director - Myra Walker Assistant Curator - Dawn Figueroa Faculty Growth - Professor

Scou 124B Scou 124C N/A

1 1 0

160 115 0

1 1 2

130 130 130

130 130 260

Classrooms Seminar Room

Scou 129

1

1199

1

1500

1500

Galleries Gallery Visitor Welcome Center

N/A Scou 124

0 1

0 171

1 1

1500 900

1500 900

Labs Photo Lab (currently part of classroom) Conservation Lab (currently part of collection storage)

Scou 129 Scou 125

1 1

0 0

1 1

400 900

400 900

Support Spaces Workroom/Resource Room Non-Artifact Storage Room Intake Room Collection Storage

N/A Scou 118 Scou 127 Scou 125

0 1 1 1

0 119 191 3980

1 1 1 1

600 900 900 9000

600 900 900 9000

Total Spaces Assignable Square Feet Net to Gross @ 45% = Assignable SF x (1/(1-45%))= Department Gross SF

342

9 0.8181

13 5,935 4,855

17,120 14,006

10,790

31,126

-

UNT CVAD Program Report



4.6.7 DESIGN:TEXAS FASHION COLLECTION SEMINAR ROOM ROOM DETAIL SHEET

Room Detail Sheet : TFC Seminar

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 1575 (1500) ROOM DIMENSIONS: 35’ x 45’

(30’ x 50’)

NUMBER OF OCCUPANTS: up to 65 UTILIZATION (hours/day and general time of day): 8am to 5pm, some Saturdays and evenings IS ROOM SHARED WITH OTHERS? (list group(s)): Yes; other faculty RESOURCES SHARED WITH OTHERS: Smart classroom equipment ADJACENCIES (internal & external): Connect to Visitor’s Center; Ground Level WINDOWS / NATURAL LIGHT: No ACOUSTICS: No SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: tile Base: Walls: Ceiling:

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Fluorescent overhead, with dimmable can lights for lectures POWER (qty & type): 120V x 10 outlets EMERGENCY POWER (yes / no, qty.): path lights Standard DATA (qty & type): Provide Category 6A cable from the nearest Telecom Room to support two (2) network connections to support Audio Visual systems. VOICE (qty & type): Provide Category 6A cable from the nearest Telecom Room to support one (1) voice connections. AUDIOVISUAL (qty & type): Dual wide aspect ratio projection screens with high definition projectors. Simple, intuitive control system. High quality audio system with listen assist. Digital video and audio inputs at Instructor location. Web camera and room microphone for Skype sessions. PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No

MIN. CEILING HEIGHT: 10’

FURNITURE, FIXTURES & EQUIPMENT

SPECIAL REQUIREMENTS / NOTES:

MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): A. 80 chairs B.12 tables, , sofa (35”w x 27”h x 88”i) C. lecturn (30”w x 27”d x 41”h) D. computer cart (18 ¼” w x 25”d x 42”h) E. white board (min. 72”w x 48”h) F. tack board (min. 72”w x 48”h)

344

-

UNT CVAD Program Report


4.6.7 DESIGN:TEXAS FASHION COLLECTION SEMINAR ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

345


4.6.7 DESIGN:TEXAS FASHION COLLECTION GALLERY ROOM DETAIL SHEET

Room Detail Sheet : TFC Gallery

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 1500 with 600 SQ of staging

BUILDING SYSTEM REQUIREMENTS SECURITY: 24 hour surveillance, locked and alarmed when not monitored

ROOM DIMENSIONS: 30’ x 50’

TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): recess, adjustable lighting, UV filtered, NO LED lighting

NUMBER OF OCCUPANTS: up to 60

POWER (qty & type): 120V x 5 outlets

UTILIZATION (hours/day and general time of day): 10am to 5pm daily, closed Sundays

EMERGENCY POWER (yes / no, qty.): No

IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: open to UNT and general public ADJACENCIES (internal & external): Ground level WINDOWS / NATURAL LIGHT: maybe 1 wall of windows ACOUSTICS: No SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Large double glass door entrance ROOM FINISHES: Standard U.N.O. Floor: cement Base: cement Walls: drywall Ceiling: vaulted MIN. CEILING HEIGHT: Gallery height

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): A. movable platforms that can be configured multiple ways (18 @ 4’ x 4’)

DATA (qty & type); Provide Category 6A cable from the nearest Telecom Room to support three (3) network connections to support video computer screen on gallery wall, gallery desktop computer, and video monitor outside of gallery VOICE (qty & type): No AUDIOVISUAL (qty & type): No PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Low humidity not to exceed 59% VENTILATION: Standard AIR CHANGES: Should be minimal for preservation HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: Must meet museum facility requirements as set by the AAM, Handicap access, Fire/smoke detection and fire suppression system, climate control

BUILT-IN (qty & type): N/A FURNITURE (qty & type): B. 2 display cases for beaded handbags and other accessories (47 ¾”w x 38”h x 20”d) inside glass (46 ½”w x 8 7/8”h x 19”d) C. gallery desk D. video screen

346

-

UNT CVAD Program Report


4.6.7 DESIGN:TEXAS FASHION COLLECTION GALLERY ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

347


4.6.7 DESIGN:TEXAS FASHION COLLECTION VISITOR WELCOME CENTER ROOM DETAIL SHEET

Room Detail Sheet : TFC Visitor Welcome Center

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 1000 900 ROOM DIMENSIONS: 30’ x 30’ NUMBER OF OCCUPANTS: up to 60 UTILIZATION (hours/day and general time of day): Open during building hours

IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Connected to Classroom, Gallery WINDOWS / NATURAL LIGHT: No ACOUSTICS: No SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Standard ROOM FINISHES: Standard U.N.O. Floor: carpet Base: Walls: Ceiling: MIN. CEILING HEIGHT: Standard

BUILDING SYSTEM REQUIREMENTS SECURITY: Locked when not in use TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): UV filtered light, motion sensor with switch POWER (qty & type): 120V x 10 outlets EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Provide Category 6A cable from the nearest Telecom Room to support three (3) network connections. VOICE (qty & type): Provide Category 6A cable from the nearest Telecom Room to support one (1) voice connection. AUDIOVISUAL (qty & type): No PIPED SERVICES: No WATER / FLOOR DRAIN: No TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES:

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): A. Reception desk and chair B. 2 soft chairs C. lounge furniture D. Computer desk for students to research data base E. 13”d Book storage F. Displays (need more information) G. “Open” storage (glass display for ability to see but not touch)

348

-

UNT CVAD Program Report


4.6.7 DESIGN:TEXAS FASHION COLLECTION VISITOR WELCOME CENTER ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

349


4.6.7 DESIGN:TEXAS FASHION COLLECTION PHOTOGRAPHY LAB ROOM DETAIL SHEET

Room Detail Sheet : TFC Photography Lab

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 500 400 ROOM DIMENSIONS: 25’ X 20’ 20’ x 20’ NUMBER OF OCCUPANTS: 1-6 UTILIZATION (hours/day and general time of day): By use

IS ROOM SHARED WITH OTHERS? (list group(s)): yes, Fashion Design RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): Collection Storage Room; Ground level

BUILDING SYSTEM REQUIREMENTS SECURITY: Locked and alarmed when not in use TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): overhead recess or track ceiling lights that are adjustable and dimmable; free-standing photo lights POWER (qty & type): Multiple plugs/ on different circuit breakers for photo lights EMERGENCY POWER (yes / no, qty.): No DATA (qty & type); Provide Category 6A cable from the nearest Telecom Room to support one (1) network connections. Provide Category 6A cable to support Wireless connectivity. VOICE (qty & type): Cell phone will be utilized. AUDIOVISUAL (qty & type): No

WINDOWS / NATURAL LIGHT: No

PIPED SERVICES: No

ACOUSTICS: No

WATER / FLOOR DRAIN: No

SIGHTLINES: No

TEMPERATURE: Suitable for photography equipment

MIN. DOOR WIDTH & DESCRIPTION: Standard

HUMIDITY: Suitable for photography equipment

ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling:

VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No

MIN. CEILING HEIGHT: 10’

FURNITURE, FIXTURES & EQUIPMENT

SPECIAL REQUIREMENTS / NOTES: Appropriate backdrops for photography. Must be a clean space.

MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): A. Photography lighting B. equipment C. Photography wooden table (30”d x 26”h x 60”l), D. installed wall backdrop E. 3 wooden cabinets with doors (48”w x 24”d x 93”h) for equipment storage F. table for computer

350

-

UNT CVAD Program Report


4.6.7 DESIGN:TEXAS FASHION COLLECTION PHOTOGRAPHY LAB ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

351


4.6.7 DESIGN:TEXAS FASHION COLLECTION CONSERVATION LAB ROOM DETAIL SHEET

Room Detail Sheet : TFC Conservation Lab

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 1000 (600) 900 ROOM DIMENSIONS: 30’ X 20’ 30’ x 30’ NUMBER OF OCCUPANTS: 1-12 UTILIZATION (hours/day and general time of day): 8am to 5pm, flexible

IS ROOM SHARED WITH OTHERS? (list group(s)): No RESOURCES SHARED WITH OTHERS: No ADJACENCIES (internal & external): to TFC Collection Storage with windows for viewing from this room, Ground level

BUILDING SYSTEM REQUIREMENTS SECURITY: Locked when not in use TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): UV filtered, adjustable lighting POWER (qty & type): 120V x 10 outlets EMERGENCY POWER (yes / no, qty.): No DATA (qty & type); Provide Category 6A cable from the nearest Telecom Room to support one instructor station with microscope and ten (10) student network connections. Provide Category 6A cable to support Wireless connectivity and Audio Visual systems. VOICE (qty & type): Cell phone will be utilized. AUDIOVISUAL (qty & type): No PIPED SERVICES: 1 4’ x 6’ sink for the filtered water, floor drain

WINDOWS / NATURAL LIGHT: No ACOUSTICS: No SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Double doors ROOM FINISHES: Standard U.N.O. Floor: sealed concrete Base: Walls: Ceiling: MIN. CEILING HEIGHT: Standard 10’

WATER / FLOOR DRAIN: Yes; hot and cold TEMPERATURE: Standard HUMIDITY: Standard VENTILATION: Standard AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: Glass window for visitor viewing, very clean room like a bio lab

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): A. Microscopes BUILT-IN (qty & type): B.1 4’ x 6’ sink washing table with floor drain FURNITURE (qty & type): C. Large table for laying garments out (96”l x 36”d x 29”h) D. Utility sink E. Computer table switch workspace for 4-6 students F. Sewing tables (need qty. and size) G. washer H. dryer

352

-

UNT CVAD Program Report


4.6.7 DESIGN:TEXAS FASHION COLLECTION CONSERVATION LAB ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

353


4.6.7 DESIGN:TEXAS FASHION COLLECTION WORKROOM / RESOURCE ROOM ROOM DETAIL SHEET

Room Detail Sheet : TFC Workroom/Resource Room

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 600 ROOM DIMENSIONS: 30’ x 20’ NUMBER OF OCCUPANTS: 1-10 UTILIZATION (hours/day and general time of day): 8am to 5pm Monday through Friday

IS ROOM SHARED WITH OTHERS? (list group(s)): Students RESOURCES SHARED WITH OTHERS: Fashion Library accessible to UNT faculty, staff, and students

BUILDING SYSTEM REQUIREMENTS SECURITY: Locked when not in use TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): Motion sensor POWER (qty & type): No EMERGENCY POWER (yes / no, qty.): No DATA (qty & type): Provide Category 6A cable from the nearest Telecom Room to support five (5) network connections. VOICE (qty & type): Cell phone will be utilized. AUDIOVISUAL (qty & type): No

ADJACENCIES (internal & external): View to Collection Storage

PIPED SERVICES: No

WINDOWS / NATURAL LIGHT: No

WATER / FLOOR DRAIN: No

ACOUSTICS: No

TEMPERATURE: Standard, but should not get above 75F

SIGHTLINES: No

HUMIDITY: Standard, but should not get above 59%

MIN. DOOR WIDTH & DESCRIPTION: Standard

VENTILATION: Standard

ROOM FINISHES: Standard U.N.O. Floor: carpet Base: Walls: Ceiling:

AIR CHANGES: Minimal to preserve books and paper archives HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES:

MIN. CEILING HEIGHT: Standard

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): N/A BUILT-IN (qty & type): N/A FURNITURE (qty & type): A. 9 metal bookshelves to line walls, we currently have (36” x 12” x 66”)/ 1 wooden bookshelf (49.5”w x 18”d x 104”h) B. Table (96”w x 36”d x 29”h) C. 8 wooden chairs, D. Flat file storage cabinet (41”w x 29”d x 17”h) E. 5 desks and chair

354

-

UNT CVAD Program Report


4.6.7 DESIGN:TEXAS FASHION COLLECTION WORKROOM / RESOURCE ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

355


4.6.7 DESIGN:TEXAS FASHION COLLECTION INTAKE ROOM ROOM DETAIL SHEET

Room Detail Sheet : TFC Intake Room

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 750 900 ROOM DIMENSIONS: 30’ x 30’ NUMBER OF OCCUPANTS: 1-4

BUILDING SYSTEM REQUIREMENTS SECURITY: Lockable TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): motion sensor, fluorescent POWER (qty & type): 120V x 5 outlets, 220V x 5 outlets EMERGENCY POWER (yes / no, qty.): No

UTILIZATION (hours/day and general time of day): 8am to 5pm Monday through Friday

DATA (qty & type); No

IS ROOM SHARED WITH OTHERS? (list group(s)): No

VOICE (qty & type): 1 mobile phone

RESOURCES SHARED WITH OTHERS: No

AUDIOVISUAL (qty & type): No

ADJACENCIES (internal & external): Access to outside for delivery; all donations come to this room first; Conservation Lab

PIPED SERVICES: 1 washing machine, 1 dryer, 1 freezer

WINDOWS / NATURAL LIGHT: No ACOUSTICS: No SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: 2 4’ doors ROOM FINISHES: Standard U.N.O. Floor: cement Base: cement Walls: Ceiling: standard

WATER / FLOOR DRAIN: Yes TEMPERATURE: Standard HUMIDITY: Similar to a bio lab VENTILATION: Similar to a bio lab AIR CHANGES: Similar to a bio lab HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: Loading dock, very clean space, ideal have a dedicated area for a full time staff conservationists

MIN. CEILING HEIGHT: 8’

FURNITURE, FIXTURES & EQUIPMENT MOBILE (qty & type): A. 3 rolling racks BUILT-IN (qty & type): B. Hanging space C. sewing cabinets FURNITURE (qty & type): D. Freezer (35” x 21½” x 34½”) E. Table 4” x 8” F. washing machine and G. dryer H. sewing machines I. microscopes

356

-

UNT CVAD Program Report


4.6.7 DESIGN:TEXAS FASHION COLLECTION INTAKE ROOM ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

357


4.6.7 DESIGN:TEXAS FASHION COLLECTION COLLECTION STORAGE ROOM DETAIL SHEET

Room Detail Sheet : TFC Collection Storage

University of North Texas SPACE REQUIREMENTS College of Visual Arts + Design ROOM QUANTITY: 1 ASSIGNABLE SQ. FOOTAGE: 9000 ROOM DIMENSIONS: 90’ x 100’ NUMBER OF OCCUPANTS: 1-45

UTILIZATION (hours/day and general time of day): 8am to 6pm Monday through Friday, some Saturdays IS ROOM SHARED WITH OTHERS? (list group(s)): Visitors, educators, students RESOURCES SHARED WITH OTHERS: Collection is a resource for students, other museums and galleries, other universities, educators ADJACENCIES (internal & external): Ground level near Gallery next to the Conservation Lab WINDOWS / NATURAL LIGHT: No natural light ACOUSTICS: No SIGHTLINES: No MIN. DOOR WIDTH & DESCRIPTION: Double doors ROOM FINISHES: Standard U.N.O. Floor: Base: Walls: Ceiling: MIN. CEILING HEIGHT: 14’

FURNITURE, FIXTURES & EQUIPMENT

BUILDING SYSTEM REQUIREMENTS SECURITY: 24 hour surveillance, locked when not in use TYPE OF ARTIFICIAL LIGHTING (i.e. task, overhead & fluorescent, etc.): UV filtered lighting. No LED lamps POWER (qty & type): No Standard x 5 outlets EMERGENCY POWER (yes / no, qty.): No DATA (qty & type); Provide Category 6A cable from the nearest Telecom Room to support five (5) network connections. Provide Category 6A cable to support Wireless connectivity. VOICE (qty & type): No AUDIOVISUAL (qty & type): No PIPED SERVICES: Computer, electric, Wi-Fi WATER / FLOOR DRAIN: No TEMPERATURE: 65F to 70F degrees HUMIDITY: 50% or less VENTILATION: HVAC System, not sealed; airflow important AIR CHANGES: Standard HAZARDOUS MATERIALS & STORAGE METHOD: No SPECIAL REQUIREMENTS / NOTES: Floor structural load to accommodate high density storage

MOBILE (qty & type): 1 mobile BUILT-IN (qty & type): 1 landline FURNITURE (qty & type): In general a combination of shelving, high density storage and hanging racks A. 6 Bookshelves: 36”w x 12”d x 66”h (Ref Library & notebooks) B. 52 Wooden cabinets w/ doors: 48”w x 24”d x 93”h (Hats, Shoes, access, etc) TO BE REPLACED C. 1 unit of metal drawers (near front AC): 94”w x 24”d x 98”h (Study/Textiles/etc) D. 5 track shelves above bookshelves: 46”w x 12”d x 6”h (Misc storage stands, etc) E. 2 metal shelving units (near back AC): 48”w x 24”d x 86”h (Custom for boxes) F. Wooden shelves: 384”w x 18”d x 104”d (Dolls, hatboxes, etc) TO BE REPLACED

358

G. Metal shelves (near TFC entrance door): 158”w x 24”d x 128”h (Show and tell) H. 68 hanging storage units: 112”w x 28”d x 156”h I. Bookcase (near classroom door – drawers and shelves): 95”w x 24”d x 12”h (Archives/Study) J. Edward’s Desk: 72”w x 22”d x 29.5”h K. Edward’s Chair L. 1 two-drawer lateral black file cabinet: 41”w x 18”d x 27”h M. 1 large work table: 96”w x 48”d x 37”h TO BE REPLACED N. 1 cabinet by front door: 29.5”w x 20.25”d x 35.5”h O. 4 misc rolling chairs P. 1 antique mirror on rolling base Q. 2 rolling ladders (1large 1small) -

UNT CVAD Program Report


4.6.7 DESIGN:TEXAS FASHION COLLECTION COLLECTION STORAGE ROOM PLAN

NOT TO SCALE -

UNT CVAD Program Report

359


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.