Range Of Technical Features And Services Festspielhaus St. Pölten | 2024

Page 1

1

Range of technical features and services General Information ........................................................................................... 3 Operator – Contact ............................................................................................. 3 Season .............................................................................................................. 3 Performance areas ............................................................................................. 3 Building Specifications ................................................................................... ……..3 Großer Saal............................................................ Fehler! Textmarke nicht definiert. Auditorium ......................................................................................................... 4 Stage ................................................................................................................ 4 Acoustics ........................................................................................................... 4 Großer Saal: Technical Data – Stage .................................................................... 5 Großer Saal: Batten distances from central axis...................................................... 6 Großer Saal: Single Loads on hand counter-pulley Fehler! Textmarke nicht definiert. Batten lengths ................................................. Fehler! Textmarke nicht definiert. Batten Cross-Section ........................................................................................... 8 Transport to stage ........................................... Fehler! Textmarke nicht definiert. 1. Delivery via underground car park, level - 6,25 m ............................................ 8 2. Transport via left side stage, level + / - 0,0 m ................................................ 8 3. Freight elevators for other halls from understage ............................................ 8 Großer Saal: Stage Equipment ............................................................................. 8 Platform / Podium ............................................................................................ 8 Chairs .............................................................................................................. 8 Curtains ........................................................................................................... 9 Instruments ...................................................................................................... 9 Concert-Pianos ............................................................................................... 9 Rehearsal-Pianos ............................................................................................. 9 Großer Saal: Technical Data – Sound equipment ................................................... 9 Sound control equipment .................................................................................. 9 Mobile audioequipment ....................................................................................10 PA-System ....................................................................................................11 Microphones ...................................................................................................11 Sound distribution facilities .............................................................................12 Video equipment ............................................................................................12 Mobile video equipment ...................................................................................13 Großer Saal: Technical Data – Lighting equipment .................................................13 Lighting control equipment ...............................................................................13 Dimmer circuits ..............................................................................................13


2 Spotlights ......................................................................................................13 Lighting distribution facilities ...........................................................................15 Technical Data – House Communications .............................................................15 In-House PA system ........................................................................................15 Stage monitoring system .................................................................................16 Intercomsystem ..............................................................................................16 House radio system .........................................................................................16 House video system .......................................................................................16 Kleiner Saal ...................................................................................................... 16 Sound distribution facilities .................................................................................16 Lighting distribution facilities ...............................................................................17 Probebühne 1 ................................................................................................... 17 Sound distribution facilities .................................................................................17 Lighting distribution facilities ...............................................................................18 Probebühne 2 ................................................................................................... 18 Sound distribution facilities .................................................................................18 Lighting distribution facilities ...............................................................................18


3

General Information Operator – Contact NÖ Kulturszene Betriebs GmbH Festspielhaus St. Pölten Kulturbezirk 2 3109 St. Pölten T: +43 (0) 2742/90 80 80-0 F: +43 (0) 2742/90 80 81 E: office@festspielhaus.at

Season From early September to June

Performance areas The Festspielhaus has four performance halls available: the Großer Saal, located at the centre of the building, takes an audience of 1.079 (1.009 chairs) while the Kleiner Saal seats 230 persons. Two smaller halls – Rehearsal stage 1 + 2 - can seat up to 100 persons each and are also used for rehearsals and performance preparations. Built in 1997 by architect Klaus Kada. The Festspielhaus was opened on March 1, 1997.

Building Specifikations The generously spaced Foyer (Entrance Hall) is accessible via the main entrance (Milleniumstraße). The Hall divides primarily into the actual entrance – and theatre bar level; further into several intermediate levels witch can be used as lounges or bar rooms during intermissions. Additionally the Foyer area offers several possibilities for exhibitions etc. The entrance hall is directly accessible from the underground car park by escalator. The hall area also houses the day & evening box offices and cloak rooms.


4

Mainhall Auditorium The elegant Main Hall with 1.009 comfortably upholstered seats can be accessed through four ground-level entrance doors. The stalls side galleries can be reached from the stalls area and the entrance hall. Two staircases and an upstairs lobby lead to the dress circle and side galleries. In the back stalls area standing room for approximately 70 people is available, if required.

Stage The stage is a full stage with safety curtain, grid floor, lower stage and two elevating platforms in the orchestra pit. A mobile acoustic shell is available for concerts. Two swivelling lighting telari in the auditorium and a lighting bridge in the auditorium ceiling enable quick changeover from concert to theatre operations. Sets, décors and furniture are transported to the hall via a loading area in the underground car park and on to the left side stage in the Main Hall on a two-tier transport platform. A ramp at the South side of the building at stage – level offers another transport route. In the West and South side of the building the stage tower is surrounded by a five-storey dressing room - and office wing.

Acoustics Reverberation time and sound power factor (degree of intensity) of the house are in the ideal range; so the natural liveliness of sound in the Großer Saal is emphasised when used specifically for symphonic concerts, operas and musicals. Reverberation time: TN60: 2,5 sec. At 125 Hz, dropping to 1,5 sec. At 4kHz. Power factor: G80: - stage area betw. –30 & -25 dB. - stage and hall betw. –26 & - 23 dB. As the hall incorporates a long acoustic resonance, productions with electro-acoustic support (speeches, meetings, pop- music events) have to take into account a certain amount of sound blur. Some reflections from rear wall are possible at high sound levels.


5

Mainhall: Technical Data - Stage Performance area, width:

max. 19,50m

Performance area, depth:

11,8 m from the iron curtain up to batten 45

Stage space, width:

33,1 m at stage level

Stage space, depth:

18,3 m from safety curtain to backstage perimeter

Stage space, surface area:

462 m² total

Proscenium width:

travelling proscenium towers, infinitely variable between 12 and 18,0 m; load capacity 1,0 kN per running metre on railing

Proscenium height:

infinitely variable between 0,5 and 10,0 m, load capacity 1,0 kN per running metre on railing

Backstage:

17,2 m wide, 6,0 m deep

Side stage South:

2,4 m wide, 9,7 m deep

Side stage North:

5,0 m wide, 11,5 m deep

Fly space height:

22,4 m above stage level

4 Working galleries:

1. + 10,5 m, 2. + 14,0 m, 3. + 16,7 m, 4. + 19,5 m

Traps options:

4 fields with 8 covers each (1,10 m x 1,015 m wide)

Forestage:

two infinitely variable travelling orchestra platforms (reselected positions: -6,15; -2,3; -1,0; +/- 0,0); cannot be used for scenery! Operating speed: a constant 0,05 m/sec

Forestage depth:

6,4 m to the iron curtain

Orchestra platform 1

(platform on auditorium side): 17,295 x 2,50 m, area 38,5 m²; load capacity 500 kg/m²

Orchestra platform 2

(platform on stage side): 16,135 x 2,50 m, area 36,0 m²; load capacity 500 kg/m²

Orchestra pit:

for approx. 70 musicians

Proscenium :

infinitely variable up and down

Prosecnium pipe:

500 kg, lifting high 9,30 m


6

Kurtine:

14,5 t, approx. 18,5 x 10 m

V1 main curtain:

electric draping and parting; lifting height 15m

V2 sound damping curtain:

total load capacity max. 2,000 kg

V3 screen:

750 kg, lifting height approx. 21,8 m

Battens:

2 - 11, 13- 23 and 25 - 45 decor battens; load capacity 750 kg; lifting height approx. 21,8 m.

heavy-weight pulleys:

1,12 and 24; load capacity 2500 kg; these cannot be used for guest appearances, as they are utilised to lift the acoustic damper (for orchestra).

panorama battens:

linkable: inner panorama and outer panorama, load capacity 500 kg

Backstage battens:

load capacity 750 kg

Chainmasters:

6 Stk, load capacity 800 kg

ATTENTION:

SZ1 cannot be used for guest appearances, as they are utilised to lift the acoustic damper (for orchestra).

Mainhall: Batten distances from central axis Zug

Description / Type

Kurtine

iron curtain (width: 23 cm)

V1

main curtain, mech. (draping, parting Vmax=3 m/s) sound draping, mech. (hoisting speed up to 1.2 m/s) screen (gauze), manual

V2 V3 Proscenium

Distances Loads +/-000 mm

Eigengewicht 14,5 t

+177 mm

-

+397 mm

2000 kg

+597 mm

750 kg

+847 mm

PBZ1

Proscenium pipe 1

+1327 mm

500 kg

PBZ2

Proscenium pipe 2

+1677 mm

500 kg

SZ1

heavy-weight pulley

+2427 mm

2500 kg

Z2

pipe

+2817 mm

750 kg

Z3

pipe

+3030 mm

750 kg

Z4

pipe

+3225 mm

750 kg

Z5

pipe

+3425 mm

750 kg

Z6

pipe

+3625 mm

750 kg

Z7

pipe

+3830 mm

750 kg

Z8

pipe

+4020 mm

750 kg

Z9

pipe

+4220 mm

750 kg

Z10

pipe

+4440 mm

750 kg


7 Z11

pipe

+4628 mm

750 kg

SZ12

heavy-weight pulley

+4824 mm

2500 kg

Z13

pipe

+5041 mm

750 kg

Z14

pipe

+5236 mm

750 kg

Z15

pipe

+5440 mm

750 kg

Z16

pipe

+5640 mm

750 kg

Z17

pipe

+5830 mm

750 kg

Z18

pipe

+6030 mm

750 kg

Z19

pipe

+6230 mm

750 kg

Z20

pipe

+6630 mm

750 kg

Z21

pipe

+7020 mm

750 kg

Z22

pipe

+7228 mm

750 kg

Z23

pipe

+7428 mm

750 kg

SZ24

heav pipe y-weight pulley

+7620 mm

2500 kg

Z25

pipe

+7833 mm

750 kg

Z26

pipe

+8033 mm

750kg

Z27

pipe

+8240 mm

750 kg

Z28

pipe

+8440 mm

750 kg

Z29

pipe

+8640 mm

750 kg

Z30

pipe

+8840 mm

750 kg

Z31

pipe

+9030 mm

750 kg

Z32

pipe

+9230 mm

750 kg

Z33

pipe

+9445 mm

750 kg

Z34

pipe

+9623 mm

750 kg

Z35

pipe

+9840 mm

750 kg

Z36

pipe

+10036 mm

750 kg

Z37

pipe

+10236 mm

750 kg

Z38

pipe

+10435 mm

750 kg

Z39

pipe

+10632 mm

750 kg

Z40

pipe

+10829 mm

750 kg

Z41

pipe

+11033 mm

750 kg

Z42

pipe

+11226 mm

750 kg

Z43

pipe

+11426 mm

750 kg

Z44

pipe

+11630 mm

750 kg

Z45

pipe

+11826 mm

750 kg

H1

pipe

+12370 mm

750 kg

H3

pipe

+13440 mm

750 kg

PANLI

Panorama pipe stage left and right, linkable with pipe 44 Panorama pipe stage left and right, linkable with pipe 45 Panorama pipe stage left and right, linkable with pipe 44 Panorama pipe stage left and right, linkable with pipe 45

PANLA PANRI PANRA

500 kg 500 kg 500 kg 500 kg


8

Batten lengths: Battens 2-11, 13-23 u. 25-45: 19,10 m, with extension 21,10 m Battens SZ1, SZ12, SZ24: 19,10 m, with extension 21,10 m Battens H1+H3: 12,50 m Panoramapipe distance inside: 19,50 m Panoramapipe distance outside: 21,24 m Prosceniumpipe 1+2: 11,80 m V3: 21,11 m Batten diameter: 48 mm Hoisting speed pipe: 0 – 1,20 m/s, infinitely variable Hoisting speed heavy pully pipe: 0 – 0,40 m/s, infinitely variable Hoisting speed proscenium pipe: 0 – 0,30 m/s, infinitely variable Hoisting speed by using Federleittrommel: 0 – 0,40 m/s, infinitely variable

Transport to Stage 1. Delivery via underground car park, level –6,25 m Height of loading ramp: approx. 1,2 m Lowerstage gate: width 2,2 m, height 2,95 m Transport platform: Double - storied podium on left-hand side of rear stage housing wall, broad side wood – panelled, so loading via narrow side only. Width 1,83 m, length 8,4 m, area 15,4 m² Lifting height: -6,25 m to +/- 0 m, loading level: -5,15 m Total payload: 10.000 kg static, 5.000 kg dynamic, weight distributed on both platform floors Payload per platform floor: maximum 5.000 kg Lifting speed: 0,10 m/s

2. Transport via left side stage, level +/- 0,0 m: Height of loading ramp: 1,2 m Side stage gate: width 2,1 m, height 2,95 m

3. Freight elevators for other halls from understage: Rehearsal stage 1 + 2 (El. 1) approx. 1,65 x 2,70 x 2,60 (w x d x h), maximum payload: 2500 kg Box (El. 2) approx. 1,85 x 3,00 x 2,60 (w x d x h), maximum payload: 3125 kg

Mainhall: Stage-Equipment Platform/Podium platform/rostrum

60x platform/rostrum 100 x 200 cm; 6x platform/rostrum 100 x 100 cm; stand-height: 17cm, 33.3cm, 50cm, 66.7cm, 83.3cm, 100cm.


9

Chairs 110 Musicians-Chairs Tpye Selmer Modell W+S 710 : h=48cm, w=45cm, d=40cm; 240 Chairs Lether, black 80 Chairs cloth, black 100 music stands: 50 lighting equiped for orchestra pit

Aushang / Curtains Backdrops / Black curtains: (Velvet)

1 Stk. 1800 x 1000 cm 2 Stk. 1200 x 1000 cm

Leg (Velvet/black):

12 Stk. 420 x 1000 cm 4 Stk. 250 x 1000 cm

Border (Velvet/black):

1 Stk. 2000 x 240 cm 1 Stk. 2000 x 350 cm 1 Stk. 2000 x 350 cm 1 Stk. 2000 x 350 cm 1 Stk. 2000 x 450 cm 1 Stk. 2000 x 350 cm

Gaze

1 Stk. 1800 x 1200 cm black 1 Stk. 1800 x 1200 cm white 1 Stk. 1900 x 1000 cm (width x height)

Opera:

Instruments Concert-Pianos 1 Stk. Concert-Pianos Steinway "Hamburg", Modell D 274 1 Stk. Concert-Pianos Bösendorfer "Imperial", Modell 290, black(444 Hz) 1 Stk. Concert-Pianos , Bösendorfer, Modell 225, black (443 Hz)

Rehearsal–Pianos 1 Stk. Bösendorfer Pianino, Modell 130 Classik, black 1 Stk.Young Chang-Pianino, Modell U-131, black

Mainhall: Sound Equipment Sound control equipment (control room on the balcony with acoustic curtain) Mixing console:

Digico SD10 digital Mixing-System connected to the stageracks( Digico SD-Rack) via optical-fiber Digico SD12 No.1 – Front of HouseConsole - connected via optical fibre to the system Digico SD12 No.2 – option as a Monitor-Console or On-stageSetups – connected via optical fibre to the system


10 2x Stage Racks consisting of 72 Microphone/Line-Inputs, 16 AES/EBU-inputs(used for Sennheiser 9000); 8 channels analog outputs, 8 channels AES/EBU I/O, 16 channels Dante I/O (used for d&b DS10 Dante-Bridge) 1x mobile Stagerack (D-RACK) with 32 Mic/Line Inputs, 8 analogue Outputs and $ AES/EBU Outputs

Effects

Lexicon PCM 80, Aphex Exciter AEH 250, 1x TC-Electronics Finalizer Waves Impact-Server + Superrack with Platinum-bundle

Wireless / Microport equipment

Sennheiser EM 9046 UHF digital , 16 channels, 16 pocket transmitters (10x SK 9000, 6x SK6212) , 8 hand-held transmitters (SKM 9000) incl. remote software WSM 4.4.5 Frequency range: 470 to 558 MHz

Playback / Recording

AKAI DD 1000, MO- disc player with remote editing; 1.3 GB Tascam DA 30 MK II DAT recorder, Denon C640 CD-Player, 2 x Sony MDS-E11 Minidisc-recorder, Tascam CD RW5000 CD recorder

Socket bays / Patchbays

All analogue audio connections are effected via 8 TT socket bays. Transmitting lines to commentator cabin and main amplifying control room available.

Misscellaneous

MOTU-Miditimepiece, Riedel TC (timekeeping set-up), 4–channel video monitor, TV-monitor, PC-intel core i5 (over Madi 28/96KHz channels I/O to mixing board) Software: Samplitude Pro 11, d&b R1 V3, Sennheiser Microport Remote Software WSM 4.4.5

Mobile Audioequipment Mixing consols

Digico SD8-24 + Madirack( 48 mic/line inputs, 8 Line-out, 4 AES/EBU-out) Yamaha 01V96 digital mixing console, Yamaha QL1 digital mixing console + Rio32 stagebox

Loudspeakers

4x d&b C4-TOP, 4x d&b C4-SUB, 4x d&b E9, 10x d&b M4 , 4x d&b MAX, 4x d&b Y7P, 2x V7P 2x d&b E3, 2x d&b E12, 2x d&b E8, 8x d&b V-Gsub, 2x d&b SL-Sub 2x Verse-Audio D-Sider12, 2x Verse-Audio D-Sider10, 2x Verse-Audio Sub15

Ext. soundcard

RME Madiface USB

Analog Equaliser

4x KlarkTeknik Square One (8 ch. 1/3-oktav)

Compressors

2x BSS DPR 402, 2x BSS DPR 901 II, 3x BSS DPR 422, 1x DBX 160A


11 Gates

2x BSS DPR522

Effects

1x TC Reverb4000, 1x Lexicon PCM90, 1x Lexicon PCM80, 1x Yamaha SPX990, 1x TC D-Two Waves Extreme Server + Superrack with Mercury-Bundle

Players

1x Denon C680 (CD-Player), 2x Macbook pro

Wireless equipment

Sennheiser evolutionG3 UHF, 4 Kanäle, 4x handheld SKM 300 G3, 4x Bodypack EK 2000 Shure ULX-D, 2xQuad-receiver 4 channel, 8 handheld transmitter (KSM9 or SM58 capsule), 8 bodypack transmitter

Microphone splitter

BSS MSR 602 (32 ch.) in connection with stage distributing boxes in area of side stages main hall.

Multicoresystem

3x 60m, 24-channel HAN72

PA- System Main PA system

12x d&b V8-Top Arrayprozessed ( Parkett ) 4x d&b V8 Top (Balkon) 6x d&b V-Sub (Bass) (Main PA system only when revolving towers are open)

Centre cluster

8x d&b T10

Forestage

2x d&b V7P, 4x d&b E8

Backstage PA system

4x d&b C4-Top, 4x d&b C4-Sub

Bass array

8x d&b V-Gsub + 2x d&b SL-Sub in front of the stageedge (only possible when the orchestra pits are at audiencelevel)

Stage monitoring (variable)

4x d&b Y7P, 10x d&b M4, 4x d&b Max

Surround / Delay / Sound effects

10x EAW JF 80 (permanently installed), 6 channels

Microphones Condenser type

1x AKG C426 B, 2x AKG C 414-BULS 4x AKG C 418, 2x AKG C 419, 1x C 460 2x AKG C480, 4x AKG C 747 4x Neumann KM 140 6x Neumann KM 184 2x Neumann GFM 132 6x Crown PCC 160 2x Shure beta98c with drumclamp, 1x Shure Beta92


12 16x headsets und Lavalier (DPA,Sennheiser) Dynamic

2x AKG D 112, 1x Shure Beta52, 10x Shure SM 57, 8x Shure SM 58, 3x Shure Beta58 2x EV RE20, 2x MD421-II

D.I.

4x BSS 116/117 DI-Boxes 6x BSS AR133 DI-Boxes 4x Pro CO DB-1 DI-Boxes passive 1x BSS 416 DI-Box 4-foldly 2x sonible ML-1 stereo-di

Sound distribution facilities (junction boxes / stage boxes) A total of six equally equipped sets are available in the stage area: one set each backstage left and right, forestage left and right, and on the left and right of the orchestra pit. The sets are equipped as follows:: 12x microphone to AD-converters from the stage-racks 12x microphone connected with the sound control room in the Großer Saal (XLR) 6x line-out from the sound control room in the Großer Saal (XLR) 4x loudspeakers from main amplifying station (Speakon 4-terminal) 1x video (TV connection) 2x light signals 1x sound network (16 A, 230V, Schuko) 1 Harting 72-terminal parallel link for 10x microphone and 2x line-out Two more junction sets are available, one on the second work gallery (backstage) and one in front of the audience bridge (above orchestra pit). These are equipped as follows:: 4x microphone connected with the sound control room in the Main Hall (XLR) 4x line-out from the sound control room in the Main Hall(XLR) 2x loudspeakers from main amplifying station (Speakon 4-terminal) 1x video (TV connection) 2x light signals 1x sound power (16 A, 240V, Schuko) 1 Harting 72-terminal parallel link for 10x microphone and 2x line-out No separate monitoring mixing console is available, any mixing required for the stage loudspeakers must be done from the main mixing console in the sound control room at row14. To connect an optional monitoring mixing desk two stage junction boxes are available, equipped as follows: 48x microphone to stage-racks 48x microphone to the sound control Main Hall (harting 72 pol) combined with mobile active splitter (32-channels). 16x connecting line to amplifier rack (harting 72 pol) 1x sound power (16 A, 240V, Schuko) If absolutely necessary, a mobile FOH mixing console can be installed in row 14 – 15 of the stalls. Also is a removal of approx. 22 seats from the stalls required. These seats have to be deleted from pre-sale schedule at an early time. In case of referring requirements notice must be given to the House at least 3 month prior to the event, in case of subscription performances prior the beginning of season. For guest appearances is an additional power supply with sound grounding (earth) in the area of side stage left (GO main amplifying station) available. (3x 16 A CEE, 3x 63 A CEE). Additional Sound power is available at Stage left, right and upstage ( 3x 16A CEE)

Video Equipment


13

Video switch

Kramer 2in-1out

Video Displays

1 Sony PVM-4B1E, Preview-display, 4-foldly S/W, 4x3,75"

Cameras

Four permanently installed video cameras for the Großer Saal: stage full shot (remote controlled), stage full shot (blackoutinfrared), conductor, backstage area.

Mobile Video Equipment videoswitcher

Barco PDS-902II

Videoprojectors

2x Panasonic PT-RZ21KE; 1x Panasonic PT-D10000E 1x Panasonic PT-RZ970LBE; 2x Panasonic PT-D6000

Videomonitores

2 Panasonic BT-S1050, 10"

Playback Units

Some consumer DVD-Player , MAC/PC Notebooks

Main Hall: Technical Data - Lighting Equipment Lighting control equipment (control room in the balcony area)

Lighting control boards:

Hog 4 fullsize + Playbackwing (Highend-Systems) Hoglet 4 + Playbackwing ETC Gio optional from Kleiner Saal

Dimmer circuits Stationary

Stationary: ADB Eurodimm DD2/225, digital dimmer with dual CPU 1 dimmer cabinet: 54 x 2,5 KW, 18 x 5 KW 3 dimmer cabinet: 54 x 2,5 KW each, 12 x 5 KW, 3 x 10 KW jeweils 54 x 2,5 KW, 12 x 5 KW, 3 x 10 KW

Mobile

ADB Memopack /CEE 15 dimmer cases: 6 x 2 KW, DMX-capable 5 dimmer cases: 3 x 5 KW, DMX-capable 10 dimmerbar, 6x2,5kW each for booms


14

Spotlights Moving Lights

10 x JB Varyscan P18 LED Spots (1000 W) 1:8 Zoom (7-56°) 7000 8 x Amptown Washlight HP squarcle HPL 575W, 7-28°, dychroid colormixingsystem and autom. Barndoors FOH fixed 8 x Vari Lite VL 3500Q Spots MSR 1200W, CMY+colormixing gobos, autom. Shutter, etc. 8x Vari Lite VL 3000Q Wash MSR 1200W, CMY+colormixing 16x Mac Aura PXL RGBW Led Washlight 500W 10x Clay Paky Alpha Profile 800ST, CMY, Iris, autom. Shutter, Zoom 11°-55° 20x GLP X4 Bar 20 Striplights RGBW,

Profile lenses

29 x 1 KW, ADB DS 105, 15-31 31 x 1 KW, ADB DSN 105, 11-23 (14x fixed in FOH) 32 x 2 KW, ADB DS 205, 13-36 (12x fixed in FOH) 10 x 2 KW, ADB DVW 205, 30-54 33 x 2 KW, ADB DN 205, 10-22 (10x fixed in FOH) 20 x 750W/115V ETC Zoom (8x fixed FOH) 60x ETC S4 750W 36° (40xfix in booms) 10x ETC S4 Lustre 2 25-50°

Fresnel lenses

PC-lenses

Footlights

2x 4kW HMI Fresnel ARRI Compact + Lichttechnik shutter Dark Vader+ Rainbow 15“ PRO colorchanger 24 colors 14 x 2 KW, ADB F 201 8 x 5 KW, ADB SH 50 + PFM/400 4x 5kW Strand Pollux 24 x 1 KW, ADB C 101 + CF/185, 10-65 24 x 2 KW, ADB C 201 + CF/245, 5-65 22x Nanopix Cyc 205W RGBAW /LED asym cyc. Curve Footlight 30x cyclorama lights IRIS2 (Belma) 10x x four-colour curve footlight, Orion 4 (Belma) 16 x single footlights, Orion 1 (Belma)

Floodlights

10x sym. floodlight, Belma Octavia 1000W

PAR 64

120x

PAR 56

12x

Par 30

10x

Low Volts / Parabol

10x Pani 1000 VA / 24 Volt 2x Pani 500 VA / 24 Volt 16x Swoboda-footlight, ADB HT 2251 20 x Single ACL 24V/250W aircraft 10 Stk. Par36 Pin-Spots 6V/30W


15 Follow spots

Scroller/Colour wheels

Effekts

Booms

2 halogen follow spots, Niethammer HZU 208, 8-17° 2 local dimmers, DIM2 2 HMI follow spots 575W ETC Innofour 4digital colour scrollers, Gelbus 2, 36 colours fix FOH 2 digital colorchanger Rainbow PRO 15“ mit 24 colors for 4kW HMI Fresnel 1 x. Digiflash Strobe 2500W 2 x UV-canons 400W 1 x MDG/APS Atmosphere Hazer 1 x Hazer Look Unique 2 1 x Mirrorball 50cm 10x each equiped with 4 ETC – Source Four, 36°

Lighting distribution facilities (junction boxes) Stage left and right

dimmable: 15x 2,5 KW, 3x 5 KW, 2x 10 KW each CEE five-terminal: jeweils 10x 32 A, 4x 63 A, 1x 125 A CEE three-terminal: jeweils 5x 16 A

Tower left and right

CEE 5-Pol: 3x 32 A each

Proscenium Flypipe 1

dimmable: 23x 2,5 KW, 2x 5 KW CEE 3-Pol:, 3x 32 A

PBZ1 Proscenium Flypipe 2

dimmable: 22x 2,5 KW, 2x 5 KW

PBZ2

CEE 3-Pol:, 3x 32 A

First work gallery

dimmable: 50x 2,5 KW, 8x 5 KW, 5x 10 KW CEE fiveterminal: 4x 32 A, 4x 63 A, 2x 125 A CEE three-terminal: 4x 16 A

Second work gallery

CEE five-terminal: 4x 32 A CEE three-terminal: 4x 16 A

Fourth work gallery

dimmable: 12x 2,5 KW, 6x 5 KW, 5x 10 KW CEE five-terminal: 2x 32 A CEE three-terminal: 2x 16 A, 2x 32 A

Gridfloor spring cable reel

dimmable:: each reel 8x 2,5 KW, or CEE 3-Pol: 8x 16 A, + network-dmx

number 1-8 Gridfloor spring cable reel

dimmable: each reel 6x 5 KW oder CEE 3-Pol:6x32 A +

number 9-12

network-dmx

Grid floor

CEE five-terminal: 2x 63 A

Telari left and right

dimmable: 22x 2,5 KW, 2x 5 KW (from lighting flap) CEE 5-Pol: 1x 32 A, 2x 63 A

Lighting flap

dimmable: 22x 2,5 KW, 6x 5 KW CEE five-terminal: 32 A, 1x63 A


16 Projection booth

dimmable: 10x 2,5 KW, 6x 5 KW CEE five-terminal: 2x63 A, 1x 125 A

Auditorium/Gallery

dimmable: 22x 2,5 KW, 2x 5 KW CEE three-terminal: 6x 16 A

Auditorium/Orchestra

dimmable: 4x 5 KW CEE three-terminal: 2x 16 A

FOH Truss spring cable reel

dimmable: 6x 2,5 KW, CEE 3-Pol: 2x 16 A, + network/dmx

Technical Data - House Communications In-House PA system A permanently installed SIEMENS VARIODYN PA system with a total of 56 individual call circuits using 100V technology is available. Fixed call stations: 1. stage manager's desk (place able stage left or right) 2. doorman Mobile call stations: Mobile call stations to be installed for Box, Rehearsal stage 1 + 2. Collective call options for dressing-rooms, preparation rooms, operational rooms and the administrative area are available.

Stage monitoring system A stage monitoring system (Großer Saal or Kleiner Saal) switch able centrally from stage manager's desk, for dressing room- and production areas, is available.

Intercomsystem A permanently installed Riedel Performer digital Partyline intercom system is available: Base station: C44 Plus Headunit Remote stations: Two-channel sub stations CR2 : in the lighting control room, sound control room and at the stage manager's desk each Belt packs: 10 mobile belt packs with headsets can be plugged in on stage and on the follow spot gallery. Wireless Beltpacks: 5 2-channel wireless beltpacks are available

House radio system A sufficient number of Motorola VISAR handsets with 7 transceiving channels is available for technical production staff and event handling. Frequency range: 433.100 MHz, 433.150 MHz, 433.200 MHz, 433.250 MHz, 433.300 MHz, 433.350 MHz, 433.400 MHz.


17

Haus video system Eight permanently installed video cameras feeding into the closed circuit TV network: stage full shot (including sound channel), conductor, backstage area, Box (including sound channel), Rehearsal stage 1, Rehearsal stage 2 and Kulturbezirk. 6 TV monitors are available for mobile installation to see the conductors cam or front cam

Kleiner Saal The “Kleiner Saal” is primarily used for chamber music, but may also serve for other events. A "control gallery" on the eastern end of the hall can house technical equipment. A special feature of the “Kleiner Saal” is an acoustic adaptation option using lamellashaped elements located on the southern end of the hall. The hall is 12.75 m wide and 17 m long, with a clear height of approx. 7 m. The control gallery covers the whole width of the hall and is 2.3 m in deeps. The 220 comfortable leather chairs can be arranged in a variety of ways, the ground plan is usually adapted to the needs of the event in question (suggested seating arrangements see appendings). A stage in the dimensions 8x3,5m is defined as a standard platform to 30cm in height. Stages covering is white dance floor. When needed, mobile PA and lighting systems are employed. Groundplan Small-Hall (32K) The following equipment sets are available:

Sound distribution facilities (junction boxes) Main set

12x microphone to accessory set (XLR) 4x microphone to sound control room in Main Hall (XLR) 4x line-out from sound control room in Main Hall (XLR) 4x loudspeakers from central amplifying station (Speakon four-terminal) 1x video (TV connection) 2x light signal 1x sound network (16 A, 240V) 1x sound power (16 A Schuko)

Accessory set

12x microphone to main set (XLR) 4x loudspeakers from central amplifying station (Speakon four-terminal)

Lighting distribution facilities (junction boxes) Main set

CEE five-terminal: 1x 32 A CEE three-terminal: 2x 16 A 2x DMX (XLR five-terminal)

Accessory set

CEE five-terminal: 1x 32 A 3x DMX (XLR five-terminal)


18

Dimmerchannels 1x 6x2,5kW ADB Memopack /CEE 1x Dimmerrack 24x2kW Strand LD90

Lightingdesks ETC Gio

Spots Profilscheinwerfer

4x 1,2kW ADB DS 105 Zoom, 15-31° 8 1,2kW ADB DSN 105 Zoom 11-23° 6x ETC S4 575W 36° 4x ETC S4 575W 25-50° junior

Lensinstruments

12x 1,2kW ADB F 101

Rehearsal stage 1 Rehearsal stage 1 is 15.5 m long, 10 m wide and 5 m high; mainly used as a rehearsal room, it is also available for other events. The hall is decorated with black wood panelling all around. The southern facade is glassed in and can be fully closed off with light-tight slatted blinds. Decorations, lighting and PA system can be installed on a grid made of 48-mm tubes suspended from the ceiling. Seating is variable, depending on the type of event. Rehearsal stage 1 is linked with the public area of the Main Hall via the staircase in the southern lobby and can also be accessed independently via the southern staircase and a passenger lift. Mobile PA and lighting systems are used as required. The following equipment sets are available:

Sound distribution facilities (junction boxes) Main set

11x microphone to accessory set (XLR) 4x microphone to sound control room Main Hall (XLR) 4x line-out from sound control room Main Hall (XLR) 4x loudspeakers from central amplifying statione (Speakon four-terminal) 1x video (TV connection) 2x light signal 1x sound network (16 A, 240V, Scuko)

Accessory set

11x microphone to main set (XLR) 4x loudspeakers from central amplifying station (Speakon


19 four-terminal)

Lighting distribution facilities (junction boxes) Main set

CEE five-terminal: 1x 32 A CEE three-terminal: 2x 16 A 2x DMX (XLR five-terminal)

Accessory set

CEE five-terminal: 1x 32 A 3x DMX (XLR five-terminal)

Rehearsal stage 2 Rehearsal stage 2 is located directly above rehearsal stage 1 and has the same dimensions: 15.5m x 10m x 5m. It was primarily designed as a ballet hall, but may also be used for other events. Part of the ceiling is a glass structure which affords a beautiful view of the night sky. The hall can be darkened by means of fabric curtains allowing for a 70 per cent blackout. Access and technical equipment are the same as for rehearsal stage 1. Rehearsal stage 1 and 2 are acoustically separated so that events can be held in either location simultaneously. Mobile PA and lighting systems are used as required. The following equipment sets are available:

Sound distribution facilities (junction boxes) Main set

4x microphone to sound control room Main Hall (XLR) 4x line-out from sound control room Main Hall (XLR) 4x loudspeakers from central amplifying station (Speakon four-terminal) 1x video (TV connection) 2x light signal 1x sound power (16 A, 240V, Schuko)

Lighting distribution facilities (junction boxes) Main set

CEE five-terminal: 1x 32 A CEE three-terminal: 2x 16 A 2x DMX (XLR five-terminal)

Accessory set

CEE five-terminal: 1x 32 A 3x DMX (XLR five-terminal)


20


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.