Simpson Strong Tie Catalog

Page 205

Wood Construction Connectors

HANGER OPTIONS Min. one #5 rebar top course (typ.)

LGU/MGU/HGU/HHGU/LGUM/HGUM

Typical Concealed Flange HGUM Installation at End of Wall

See Hanger Options General Notes. CONCEALED FLANGE • LGU, MGU, HGU, HHGU and HGUM hangers are available with one flange concealed. Specify flange to conceal. • Allowable Loads for one flange-concealed option: LGU 1.00 of published load MGU 0.88 of published load HGU 0.75 of published load HHGU 0.75 of published load HGUM see table below • MGU3.63, MGU5.25 and HGU5.25 flanges cannot be concealed.

Vertical rebar per Designer Min. one block return

Typical MGU Installation with Right Flange Concealed

Typical Concealed Flange HGUM Installation at Outside Corner

Concealed Flange – Allowable Loads with One Flange Concealed Fasteners Model No.

W (in)

H (in)

CMU/ Concrete

Joist

®

HGUM

51⁄4 to 9 11 to 30

End of Wall

Titen HD Anchors

SDS Screws

8-5⁄8"x5"

24-1⁄4"x21⁄2"

Outside corner

CMU Wall DF/SP/SCL Beam Uplift Download (160)

Concrete Wall CMU/Concrete Wall DF/SP/SCL Beam DF/SP/SCL Beam Uplift Uplift Download Download (160) (160)

1285

3150

5750

7025

3150

3" min. to top of wall (typ.)

7555

SKEWED • LGU, MGU, HGU, LGUM and HGUM hangers are available skewed up to 45°. • Apply the following reduction factors to published loads: Reduction Factors for Skewed LGU, MGU, HGU Model LGU MGU/HGU less than 6" wide MGU/HGU 6" and wider

Beam Cut Square Cut Bevel Cut Square Cut Bevel Cut Square Cut Bevel Cut

Download 0.90 0.90 0.75 0.80 0.75 0.80

Uplift 0.60 0.60 0.65 0.65 0.55 0.55

Shaded cells grouted and reinforced per Designer (min.)

• For LGUM and HGUM see table below. • Concealed flanges are not available with skewed models.

Typical Concealed Flange HGUM Installation at Outside Corner

Typical Skewed MGU Installation

LGUM/HGUM Allowable Loads for Skewed (L/R) Applications

LGUM26-2X LGUM26-3X LGUM26-4X LGUM46X LGUM28-2X LGUM28-3X LGUM28-4X LGUM48X LGUM210-2X LGUM210-3X LGUM210-4X LGUM410X HGUM5.25X HGUM5.50X HGUM7.00X HGUM7.25X HGUM9.00X

Fasteners CMU/Concrete Joist Titen HD® SDS Anchors Screws

Allowable Loads CMU/Concrete (DFL, SP, LVL, PSL, LSL) Uplift Download (160) (100/115/125)

4- 3⁄8"x4"

4- 1⁄4"x2 1⁄2"

565

1965

6- 3⁄8"x4"

6- 1⁄4"x2 1⁄2"

1085

3080

8- 3⁄8"x4"

8- 1⁄4"x2 1⁄2"

1605

4190

8- 5⁄8"x5"

8- 1⁄4"x2 1⁄2"

1430

6455

8- 5⁄8"x5"

8- 1⁄4"x2 1⁄2"

1440

5820

1445

5185

15" min. to end of wall

Top View HGUM Skewed Right Bevel Cut 0˚

12" min. to end of wall

Top View LGUM Skewed Right Square Cut 0˚

5

8- ⁄8"x5"

1

1

8- ⁄4"x2 ⁄2"

Specify angle ≤ 45˚

Specify angle ≤ 45˚

Hanger Options

C-2011 © 2011 SIMPSON STRONG-TIE COMPANY INC. PRINTED 12/10

Model No.

MBHA See Hanger Options General Notes. SKEWED SEAT • Seat can be skewed at 45° only. The maximum allowable download is 3495 lbs. and 1585 lbs. uplift for Height 7 1⁄4". For all other models, use the table listed download and uplift of 2390 lbs.

Typical MBHA Skewed Right Installation 209


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.