ACO Technologies - ACO Qmax Technical Data

Page 1

Uniclass L7315 + L2123

EPIC J3413

CI/SfB (52.5)

The most advanced drainage system of its kind ACO Qmax 速 Technical Data

In6


ACO Qmax® System

TECHNICAL DATA Contents

Load Classes

3

ACO Qmax® 600 System Pedestrian and Car Park applications

4

Highway, Distribution Centre and Airport Pavement applications

5

Accessories

6

ACO Qmax® 900 System Pedestrian and Car Park applications

7

Highway, Distribution Centre and Airport Pavement applications

8

Accessories

9

ACO Qmax® Flow Regulators

10

Geometry and Properties Data

11

ACO Qmax® System

2


ACO Qmax速 System

TECHNICAL DATA Load Classes ACO Qmax速 is suitable for use in all load class applications. The patented beam feature enables use of the optimum pavement reinforcement details when dealing with specialist and high load situations, thereby reducing total cost and ensuring speed of installation is not compromised. Additional reinforcement may be specified in the concrete surround for higher load applications.

ACO Qmax速 is suitable for the following applications: Group1

Group 2

Group 3

Group4

Group 5

Group 6

BS EN 1433:2002 Load Class Load Class A

Load Class B

Load Class C

Load Class D

Load Class E

Load Class F

15kN

125kN

250kN

400kN

600kN

900kN

Pedestrian

Private car parks

Public car/van parks

Highways

Distribution centres

Airport pavements

The ACO Qmax速 channel system is protected by patent and registered design rights. All intellectual rights are the property of ACO Technologies plc.

3


ACO Qmax® 600 System

TECHNICAL DATA Pedestrian and Car Park applications - 600 system:

A B C D

Ovoid Channels

Order No

Dimensions (mm) Ovoid section WxH

Nominal length (mm)

Overall height Slot width (mm) (mm)

Nominal waterway intake Weight area (mm2) (kg)

401002

400 x 600

2000

10

20,000

2

38

642mm

2

940

600mm

880mm Invert 940mm

400mm

2000mm

Each channel section, manufactured from tough and corrosion resistant MDPE is supplied complete with:

Discrete galvanised steel heel safe (10mm slot width) continuous waterway inlet slot

Nominal waterway inlet area: 10000mm2/m

Channel assembly and connection fixings

Ovoid Channel complete with Side Inlets Dimensions (mm) Nominal Slot Ovoid section length width Order No W x H (mm) (mm)

Overall height (mm)

Nominal waterway intake area (mm2)

Finished road level to Invert of nominal bore pipe connection Weight (kg) Ø150mm Ø225mm Ø300mm

401013

940

10,000

23

4

673

710

940mm

400mm

880mm Invert

1000mm

635

600mm

3

Ø380mm

10

642mm

1000

Ø200mm

400 x 600

Notes 1. 1-metre channels supplied with symmetrical horizontal inlet spigots for easy pipe connections in vitrified clay, concrete or plastic. 2. 150mm, 225mm and 300mm nominal bore inlet pipes accommodated. 3. Side inlet spigots are supplied blank and easily opened with a handsaw or disc cutter. Connection to pipes achieved by selecting appropriate flexible couplings supplied by others. 4. For reference, actual pipe connection spigot outside diameters: 200mm and 380mm.


ACO Qmax® 600 System

TECHNICAL DATA Highway, Distribution Centre and Airport Pavement applications - 600 system:

D E

F

Ovoid Channels

Order No

Dimensions (mm) Ovoid section WxH

Nominal length (mm)

Overall height Slot width (mm) (mm)

Nominal waterway intake Weight area (mm2) (kg)

401000

400 x 600

2000

30

60,000

38

642mm

940

2000mm

940mm

880mm Invert

600mm

400mm

Each channel section, manufactured from tough and corrosion resistant MDPE is supplied complete with:

Heavy duty hot dipped galvanised steel edge continuous waterway inlet slot protection frame 40mm x 40mm x 4mm

Nominal waterway inlet area: 30,000mm2/m

Heavy-duty concrete anchors 150mm long, 500mm centres

Channel assembly and connection fixings

Ovoid Channel complete with Side Inlets Dimensions (mm) Nominal Slot Ovoid section length width Order No W x H (mm) (mm)

Overall height (mm)

Nominal waterway intake area (mm2)

Finished road level to Invert of nominal bore pipe connection Weight (kg) Ø150mm Ø225mm Ø300mm

401011

940

30,000

23

1000

30

635

673

710

642mm

400 x 600

1000mm

940mm

880mm Invert

600mm

Ø380mm

Ø200mm

400mm

Notes 1. 1-metre channels supplied with symmetrical horizontal inlet spigots for easy pipe connections in vitrified clay, concrete or plastic. 2. 150mm, 225mm and 300mm nominal bore inlet pipes accommodated. 3. Side inlet spigots are supplied blank and easily opened with a handsaw or disc cutter. Connection to pipes achieved by selecting appropriate flexible couplings supplied by others. 4. For reference, actual pipe connection spigot outside diameters: 200mm and 380mm.

5


ACO Qmax® 600 System

TECHNICAL DATA Accessories - 600 system: Universal channel stop end Description

Order No

Weight (kg)

Universal channel stop end

40104

6

60mm Ø200mm

Ø250mm

722mm

642mm

Can also be used for upstream or downstream temporary works. Complete with channel connection fixings. Ø200 and Ø250 knockouts provided for pipe outlet connection.

Universal access chamber connector pair (375mm nominal bore) Description

Order No

Weight (kg)

Universal access chamber connector pair (375mm nominal bore)

40105 the pair

20 the pair

642mm

811mm

600mm

722mm

400mm

Each set providing inlet AND outlet connections to access chamber. Compatible with 375mm nominal bore TwinWall pipe and suitable for upstream and downstream channel connection. Complete with channel fixings.

EPDM Water Seal Description

Order No

EPDM Water Seal

40251

706mm

506mm

One off EPDM Seal if required to be ordered per channel, stop end or universal access chamber connector pair.

6

722mm

642mm

Ø375mm

780mm

Ø375mm

600mm

400mm


ACO Qmax® 900 System

TECHNICAL DATA Pedestrian and Car Park applications - 900 system:

A B C D

Ovoid Channels

Order No

Dimensions (mm) Ovoid section WxH

Nominal length (mm)

Overall height Slot width (mm) (mm)

Nominal waterway intake Weight area (mm2) (kg)

401502

600 x 900

2000

10

20,000

2

64

842mm

2

1240

900mm

1180mm Invert 1240mm

600mm

2000mm

Each channel section, manufactured from tough and corrosion resistant MDPE is supplied complete with:

Discrete galvanised steel heel safe (10mm slot width pattern) continuous waterway inlet slot

Nominal waterway inlet area: 10,000mm2/m

Channel assembly and connection fixings

Ovoid Channel complete with Side Inlets Dimensions (mm) Nominal Slot Ovoid section length width Order No W x H (mm) (mm)

Overall height (mm)

Nominal waterway intake area (mm2)

Finished road level to Invert of nominal bore pipe connection Weight (kg) Ø150mm Ø225mm Ø300mm

401513

1240

10,000

41

1015

1050

Ø200mm

1240mm

600mm

1000mm

1180mm Invert

3 3

940

900mm

10

Ø380mm

1000

842mm

600 x 900

Notes 1. 1-metre channels supplied with symmetrical horizontal inlet spigots for easy pipe connections in vitrified clay, concrete or plastic. 2. 150mm, 225mm and 300mm nominal bore inlet pipes accommodated. 3. Side inlet spigots are supplied blank and easily opened with a handsaw or disc cutter. Connection to pipes achieved by selecting appropriate flexible couplings supplied by others. 4. For reference, actual pipe connection spigot outside diameters: 200mm and 380mm.

7


ACO Qmax® 900 System

TECHNICAL DATA Highway, Distribution Centre and Airport Pavement applications - 900 system:

D E

F

Ovoid Channels

Order No

Dimensions (mm) Ovoid section WxH

Nominal length (mm)

Overall height Slot width (mm) (mm)

Nominal waterway intake Weight area (mm2) (kg)

401500

600 x 900

2000

30

60,000

64

842mm

1240

2000mm

1240mm

1180mm Invert

900mm

600mm

Each channel section, manufactured from tough and corrosion resistant MDPE is supplied complete with:

Heavy duty hot dipped galvanised steel edge continuous waterway inlet slot protection frame 40mm x 40mm x 4mm

Nominal waterway inlet area: 30,000mm2/m

Heavy-duty concrete anchors 150mm long, 500mm centres

Channel assembly and connection fixings

Ovoid Channel complete with Side Inlets Dimensions (mm) Nominal Slot Ovoid section length width Order No W x H (mm) (mm)

Overall height (mm)

Nominal waterway intake area (mm2)

Finished road level to Invert of nominal bore pipe connection Weight (kg) Ø150mm Ø225mm Ø300mm

401511

1240

30,000

41

1000

30

940

1015

1050

842mm

600 x 900

1240mm

1180mm Invert

900mm

Ø200mm

8

Ø380mm

600mm

1000mm

Notes 1. 1-metre channels supplied with symmetrical horizontal inlet spigots for easy pipe connections in vitrified clay, concrete or plastic. 2. 150mm, 225mm and 300mm nominal bore inlet pipes accommodated. 3. Side inlet spigots are supplied blank and easily opened with a handsaw or disc cutter. Connection to pipes achieved by selecting appropriate flexible couplings supplied by others. 4. For reference, actual pipe connection spigot outside diameters: 200mm and 380mm.


ACO Qmax® 900 System

TECHNICAL DATA Accessories - 900 system: Universal channel stop end Description

Order No

Weight (kg)

Universal channel stop end

40154

11

60mm Ø200mm

Ø300mm

Ø250mm

1022mm

842mm

Can also be used for upstream or downstream temporary works. Complete with channel connection fixings. Ø200, Ø250 and Ø300 knockouts provided for pipe outlet connection.

Universal access chamber connector pair (600mm nominal bore) Description

Order No

Weight (kg)

Universal access chamber connector pair (600mm nominal bore)

40155 the pair

37 the pair

842mm

811mm

900mm

1022mm

600mm

1022mm

842mm

591mm

780mm

591mm

900mm

600mm

Each set providing inlet AND outlet connections to access chamber. Compatible with 600mm nominal bore TwinWall pipe and suitable for upstream and downstream channel connection. Complete with channel fixings.

EPDM Water Seal Description

Order No

EPDM Water Seal

40250

1006mm

706mm

One off EPDM Seal if required to be ordered per channel, stop end or universal access chamber connector pair.

9


ACO Qmax® System

TECHNICAL DATA ACO Q-Brake™ Flow Regulator The ACO Q-Brake™ is a flow regulator which can be installed in the ACO Qmax® channel to regulate the discharge flow rate to a sewer or watercourse, and to utilise the storage capacity of the ACO Qmax® channel.

Advantages

Very compact.

Occupies no additional volume as it resides inside the channel. No extra manholes required.

Cost effective compared to most other solutions.

Easy and quick to install.

Laboratory verified performance.

Standard regulator sizes available, custom sizes easily accommodated.

304 stainless steel construction for longevity.

No moving parts. No loose parts to get lost.

Silt formation and floating debris encouraged to pass through regulator.

By-pass facility for heavy storm applications (optional).

Can be used in cascade form to increase ACO Qmax®‚ storage volume on sloping sites.

The flow regulator is cut from 3mm thick 304 stainless steel plate and is conveniently sandwiched in the recess between any two connecting channels or channel and manhole connector. The stainless steel construction ensures the design life will exceed a 30-year life.

Flow Rate (l/s)

Order No

Weight (kg)

15

ACO Qmax® 600

40278

5.0

20

ACO Qmax® 600

40279

5.0

25

ACO Qmax 600

40280

5.0

30

ACO Qmax® 600

40281

5.0

15

ACO Qmax 900

40262

14.0

20

ACO Qmax® 900

40263

14.0

25

ACO Qmax 900

40264

14.0

30

ACO Qmax® 900

40265

14.0

®

®

®

ACO has conducted full-scale laboratory trials to validate the design parameters of the combined orifice and vee notch weir. Many combinations of weir and orifice geometries can be used to best optimise the performance of the installed ACO Q-Brake™ flow regulator for a given site.

10

Note: For customised flow regulation outside the standard range, contact the ACO Drain Design Service Department. The ACO Q-Brake™ is an additional component of the ACO Qmax® System.


ACO Qmax® System

TECHNICAL DATA 1.0 ACO Qmax®: Geometry and Properties Data 1.1 ACO Qmax®: Geometry and Properties Data of the MDPE liner Order No

ACO Qmax® 600†

ACO Qmax® 900†

Ovoid

Ovoid

Cross Sectional Area (m )

0.1838

0.4135

Perimeter (m)

1.585

2.380

Hydraulic Radius (m)

0.116

0.174

Critical Velocity (m/s)

2.14

2.60

Material Thickness (mm)

4.0 nominal

6.0 nominal

Shape 2

Weight (kg) Internal Dimensions External Dimensions Inlet Slot

*

2m channel unit assembly

38

64

1m channel unit assembly

23

41

Depth (m)

0.600

0.900

Maximum width (m)

0.400

0.600 0.845

Width o/a collar (m)

0.645

o/a height (m)

0.940

Internal width (mm)

30.0 (10.0 )

30.0 (10.0††)

Corrosion protection life (years)

30*

30*

1.240 ††

In an unpolluted environment the atmospheric zinc depletion rate per 100 metres of channel run (assuming 2 microns per year) is 0.23kg / year. With a mean galvanising thickness of 70 microns, a life in excess of 30 years may be expected.

† Airport pavement, distribution centre and highway applications unless otherwise stated †† Car park applications

1.2 Geometry and Properties of Concreted Section Order No

ACO Qmax® 600

ACO Qmax® 900

Minimum Width (m)*

0.8

1.0

Minimum Depth (m)**

1.1 approx.

1.4 approx.

Invert Depth (m) incl. angle

0.880

1.180

Concrete per metre Length**

<0.7m

<1.0m3

Reinforcement

see section 2.0

see section 2.0

3

* Excluding working space and formwork ** Excluding blinding concrete 1.3 Typical Channel Arrangements Order No

ACO Qmax® 600

ACO Qmax® 900

Length to Outlet (m)

50 – 1000

50 – 1500

Catchment Depth (m)

5 – 100

5 – 200

Longitudinal Slope (%)

0.0 – 1.0*

0.0 – 1.0*

Area Drained (ha)

0.25 – 3.0

0.25 – 5.0

*

Note that by accepting a greater outlet spacing at steeper slopes then the flow velocity will tend to exceed the critical velocity

† Airport pavement, distribution centre and highway applications

11


ACO Qmax® System

LITERATURE FOR ACO QMAX®

ACO QMAX® SYSTEM

HYDRAULICS & LEGISLATION

SITEWORK & INSTALLATION

Call for literature or more information: 01462 816666

ACO Technologies plc

International Enquiries

ACO Business Park, Hitchin Road, Shefford, Bedfordshire SG17 5TE

Tel: +44 (0)1462 816666 Fax: +44 (0)1462 850957 e-mail: international@aco.co.uk website: www.aco.co.uk

Tel: 01462 816666 Fax: 01462 815895 e-mail Sales: customersupport@aco.co.uk e-mail Technical: draintechnical@aco.co.uk website: www.aco.co.uk

ACO Qmax® is a registered trademark of ACO Technologies plc. The Qmax® channel system is protected by patent and registered design rights. All intellectual rights are the property of ACO Technologies plc. Any infringement of these property rights will result in the appropriate legal action being taken. © August 2005 ACO Technologies plc. All reasonable care has been taken in compiling the information in this document. All recommendations and suggestions on the use of ACO products are made without guarantee since the conditions of use are beyond the control of the Company. It is the customer's responsibility to ensure that each product is fit for its intended purpose, and that the actual conditions of use are suitable. This brochure and any advice is provided by ACO Technologies plc (the Company) free of charge and accordingly on terms that no liability including liability for negligence will attach to the Company or its servants or agents arising out of or in connection with or in relation to this brochure or any such advice. Any goods supplied by the Company will be supplied solely upon its standard conditions of sale, copies of which are available on request. The Company's policy of continuous product development and improvement renders specifications liable to modification. Information provided in this brochure is therefore subject to change without prior notification.


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.