Commercial Gas Energy Saver Power Direct Vent 138/139 with Co-axial Vent System Water Heaters B
■ ICON HD™—Intelligent proven design combines temperature control, diagnostic codes and system ignition functions into a single control board with a digital LCD display ■ Operation mode ■ Service mode ■ Electronic ignition ■ Automatic blower motor ■ Factory installed Hydrojet® Sediment Reduction System ■ Co-axial vent
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Vitraglas® lining Automatic re-set E.C.O. Non-CFC foam insulation Protective magnesium anode rods Hand hole cleanout Sanitizing capability NSF construction available Low NOx construction available ASME code available T&P relief valve installed Low restriction brass drain valve
A K H
J D
E C Photo of PDV-80T-300-3NA
Power Direct Vent Energy Saver Models
These models meet or exceed both Thermal Efficiency and Standby Loss Requirements of ASHRAE 90.1b (Current Edition).
DIMENSIONS IN INCHES
NATURAL GAS AND LIQUID PROPANE GAS MODELS
Model Number
Gal. Cap.
PDV-80T-300-3N(A) 80 PDV-100T-360-3N(A) 100
A GPH Recovery at °F Rise*
Nat. & 1st Hour LP Delivery Input BTU/Hr. Rating
40° 100° 140°
300,000 360,000
728 291 208 873 349 249
347 419
B
C
D
Floor Top to Vent Jacket Gas Height Dia. Conn.
695/8 785/8
281/4 281/4
(A) = ASME Code Available (F) = Front Water Connection (T) = Top Water Connection For Propane Gas models change suffix “N” to “X”.
135/8 135/8
E
H
J
K
Floor Floor Floor Floor to to Hot to Cold to Top Water Water Heater Water Conn. Conn. Top Conn. Depth
513/8 603/8
207/8 207/8
633/4 723/4
653/4 743/4
445/8 445/8
(E) Low NOX Burners
PDV-80T-300E-3N(A) PDV-100T-360E-3N(A)
280,000 BTU/Hr. 335,000 BTU/Hr.
Gas Relief Water Conn. Valve Conn. Dia. Open 1 1/2 (T&F)
3/4
1 1/2 (T&F)
3/4
1 1
1st Hr. Del. Rating
40°
328 395
679 812
Approx. Shipping Weight (lbs) Std.
ASME
665 735
740 815
GPH Rec. 100° 140°
272 325
194 232
* Recoveries and First Hour Delivery Rating are based on Thermal Efficiencies of 80%. For vertical venting please consult factory for optional vent components.
For LowNOx compliance, place an “E” following the BTU Input identifier of the model number.
**Note: The standard vent kit (p/n 243-41769-01) shipped with the heater, but in a separate carton includes: horizontal vent terminal, an elbow, condensate tee, vent connector clamps, and two 39" (990mm) straight sections of co-axial vent pipe. Can be cut for installation. Optional vent kits are available and will allow for extensions up to 21 feet. For further details please reference the installation instructions.