Full Line Pocket Catalog

Page 63

Commercial Gas Energy Saver Ultra High Efficiency Water Heaters

124/125

81/4"

■ ICON HD™—Intelligent proven design combines temperature control, diagnostic codes and system ignition functions into a single control board with a digital LCD display ■ Up to 99.1% thermal efficiency ■ ASME construction available ■ Electronic controls ■ Low-NOx Premix Power Burner ■ Three pass flue system ■ Flexible venting options ■ Vitraglas® lining ■ Factory installed Hydrojet® Sediment Reduction System ■ Factory installed dielectric fittings

■ Non-CFC foam insulation ■ Four protective magnesium anode rods (except EF-100T399) ■ Two powered anode rods and one non-powered anode rod in the EF-100T-399 ■ Hand hole cleanout ■ Zero inch clearance to combustibles ■ NSF construction available ■ T&P relief valve installed ■ Low restriction brass drain valve ■ Complies with the latest ultra-low NOx requirement (14 ng/J NOx limit)

C

EXHAUST GAS INLET

81/4" AIR INTAKE

C

T&P VALVE 3/4"

3" PVC INLET

NPT GAS INLET

B 11/2" NPT OUTLET

1" NPT SPACE HEATING OUTLET

H

E

D

CLEANOUT

A 11/2" NPT INLET

G

1/2" NPT CONDENSATE CONNECTION

1" NPT SPACE HEATING RETURN 3" PVC EXHAUST

F

J

Photo of EF-60T-199E-3N

21/2" MIN.

eF Series® Energy Saver Models

These models meet or exceed both Thermal Efficiency and Standby Loss Requirements of ASHRAE 90.1b (Current Edition).

DIMENSIONS IN INCHES

NATURAL GAS AND LIQUID PROPANE GAS MODELS

A

B

C

GPH Recovery at °F Rise

Model Number

Vent Floor & Air 1st Hour Gal. Therm. Input Delivery to Air Jacket Intake Cap. Eff. % BTU/Hr. Rating 40° 100° 140° Intake Dia. Size

EF-60T-125E-3N(A) EF-60T-150E-3N(A) EF-60T-199E-3N(A) EF-100T-150E-3N(A) EF-100T-199E-3N(A) EF-100T-250E-3N(A) EF-100T-300E-3N(A) EF-100T-399E-3N(A)

60 60 60 100 100 100 100 100

96.0 93.0 92.0 99.1 98.5 97.0 92.0 93.0

125,000 150,000 199,999 150,000 199,999 250,000 300,000 399,999

(A) = ASME Code Available For Propane Gas models change suffix “N” to “X” and remove “E” from model number Example: EF-100T-150-3X. Note: The weight is the same for both ASME and Non-ASME models.

NSF Compliance Kit—p/n 265-44542-04.

187 211 265 250 309 364 405 518

364 423 558 450 597 735 836 1127

145 169 223 180 239 294 335 451

104 121 159 128 171 210 239 322

521/2 521/2 521/2 731/8 731/8 731/8 731/8 731/8

281/4 281/4 281/4 281/4 281/4 281/4 281/4 281/4

3 3 3 3 3 3 3 3

D

E

F

G

H

J

Hot Floor Cold Gas Relief to T&P Floor Water Water Floor to Floor to Approx. Valve to Gas Inlet Outlet Top of Vent Water Conn. Valve Shipping Conn. Conn. Conn. Conn. Heater Conn. Conn. Dia. Open Weight (lbs)

40 40 40 60 60 60 60 60

531/2 531/2 531/2 743/4 743/4 743/4 743/4 731/4

127/8 127/8 127/8 127/8 127/8 127/8 127/8 13

421/2 421/2 421/2 621/2 621/2 621/2 63 63

57 57 57 775/8 775/8 775/8 775/8 775/8

eF Series® Optional Equipment Features: Maxitrol Gas Pressure Regulating valve— Ensures proper supply pressure to eF unit of 7" to 11" W.C. (provided incoming pressure is between 1/2 and 2 psi). This can be ordered as a separate part, or as part of the heater. For the separate part, please use p/n 243-45517-00 Intake/ (not available for use with the EF-100T-399). Combustion Rain Cap Air Low Gas Inlet Pressure Option—Pre-assembled to allow operation at lower inlet natural gas pressure. Vent Exhaust Concentric Vent Terminal Kit—3" termination fitting provides for only one exit opening through 36 1/4" wall or roof (p/n 239-44069-01).

5 5 5 5 5 5 5 5

11/2 11/2 11/2 11/2 11/2 11/2 11/2 11/2

Model Number EF-60T-125 EF-60T-150 EF-60T-199 EF-100T-150 EF-100T-199 EF-100T-250 EF-100T-300 EF-100T-399

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

1 1 1

3/4

1

570 570 570 900 900 900 900 950

Max. 3" PVC, Max. 4" PVC, ABS & CPVC ABS & CPVC 120 ft. 100 ft. 80 ft. 120 ft. 100 ft. 80 ft. 60 ft. 50 ft.

170 ft. 150 ft. 130 ft. 170 ft. 150 ft. 130 ft. 110 ft. 100 ft.


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.