Full Line Pocket Catalog

Page 22

Residential Gas Energy Saver FVIR High Input Direct Vent Water Heaters ■ Bradford White ICON System™ ■ Reinforced seals ■ Closed combustion–Co-axial Vent System-outer pipe takes air in from the outside. Inner pipe vents combustion gases directly back to the outside ■ Vitraglas® lining ■ Factory installed Hydrojet® Total Performance System ■ Water Connections – 3/4" NPT factory installed true dielectric fittings ■ 3/4" NPT side tappings for space heating ■ Cast aluminum intake boot ■ 1" Non-CFC foam insulation

■ ■ ■ ■

Protective magnesium anode rod Factory installed heat traps T&P relief valve included Low restriction brass drain valve

73/4"

A B

F

D&G

H

J

A

K

K

E

E

NATURAL GAS AND LIQUID PROPANE GAS MODELS

DH1-504T6FBN DH1-65T6FBN DH1-75S6FBN

48 65 75

A

Floor to GPH 1st Hour** Recovery Center Line Input Delivery of Vent 90°F Rise* BTU/Hr. Rating

50,000 55,000 60,000

93 113 125

53 58 63

751/4 781/4 751/2

B

Photo of DH1-504T6FBN

Meet or exceed ASHRAE 90.1b (current standard) CEC Listed 78% Recovery Efficiency

DIMENSIONS IN INCHES

Gal. Cap.

C

C

73/4"

Direct Vent Energy Saver Models Model Number

42/43

C

Jacket Dia.

Vent Dia.

20 22 241/2

4 I.D.,6 O.D. 4 I.D.,6 O.D. 4 I.D.,6 O.D.

D

E

F

G

H

J

K

Floor to Floor to Space Floor to Space Floor to Gas Top of Heating Water Heating T&P Conn. Inlet Depth Heater Outlet Conn.

521/4 56 52

15 15 15

*Based on manufacturers rated recovery efficiency. All propane models feature a Titanium Stainless Steel burner. For propane (LP) models change suffix “BN” to “SX”. For 10 year models, change suffix from “6” to “10”. **First Hour Delivery Rating is based on the March 2010 AHRI Directory. The Standard Vent Kit (239-42979-00) is ordered and shipped seperately and the components are as follows: 4" vent tube, 6" Air Intake Tube, Vent Terminal, Inner Wall Term. Mounting Flange, Outer Wall Term. Mounting Flange, Vent Terminal Hardware, RTV Silicone Sealant, 4" Vent Elbow and a 6" Air Intake Elbow. The Vent Tube and Air Intake Tube provided in the same standard vent kit telescopes from 133⁄4" to 2311⁄16". All models come standard with side connections for space heating 3⁄4" NPT. Circulating Loop Installation Kit (Optional — Not included with the water heater) 265-43103-00 (Dielectric Unions, Isolation Valves and Extended Nipples) Telescoping Solid Vent Kit (239-47810-00) or Flexible Vent Kit (239-47812-00) can be ordered and shipped with water heater, or ordered and shipped separately For vent kit components and venting instructions, refer to Installation and Operating Manual. Optional solid vent kit : Kit “F” Telescopes from 43⁄4" to 511⁄16" Part No. 239-42516-00 Part No. 239-42517-00 Kit “G” Telescopes from 61⁄2" to 93⁄16" Part No. 239-42514-00 Kit “H” Telescopes from 133⁄4" to 2311⁄16" Kit “I” Telescopes from 4913⁄16" to 9513⁄16" Part No. 239-42512-00 Horizontal Vent Termination Only.

583/4 62 59

521/4 56 52

593/4 63 60

153/4 153/4 161/2

Approx. Shipping Weight (lbs)

313/4 341/4 351/4

(LP) Propane Gas Inputs

DH1-504T6FSX DH1-65T6FSX DH1-75S6FSX

48,000 BTU/Hr. 55,000 BTU/Hr. 57,000 BTU/Hr.

190 226 261 GPH Rec. 90°F Rise

50 58 60