Full Line Pocket Catalog

Page 13

Residential Gas Energy Saver TTW® High Performance Water Heaters

24/25

C

■ Bradford White ICON System™ ■ High input combustion system ■ Integrated Mixing Device ■ Helical fin flue ■ Vitraglas® lining ■ Factory installed Hydrojet®2™ Total Performance System ■ Water Connections – 3/4" NPT factory installed true dielectric fittings ■ Non-CFC foam insulation ■ Two protective magnesium anode rods

■ Powerful blower motor ■ Honeywell self diagnostic electronic gas control ■ Flammable vapor sensor (not FVIR compliant) ■ Electronic ignition ■ Horizontal and vertical venting ■ 3/4" NPT side tappings for space heating ■ T&P relief valve installed ■ Low restriction brass drain valve

B K

A J

H

D&G

F

E

Photo of GX-2-TW-25S6BN

Power Vent Energy Saver Models

Meet or exceed ASHRAE 90.1b (current standard) CEC Listed 82% Thermal Efficiency

DIMENSIONS IN INCHES

NATURAL GAS AND LIQUID PROPANE GAS MODELS Model Number

GX-2-TW-25S6BN GX-1-TW-55S6BN

Gal. Cap.

25 55

A

B

C

D

E

76,000 78,000

155 200

82 84

625/8 633/4

18 22

3 or 4 3 or 4

48 48

111/2 111/2

133/8 133/8

All propane models feature a Titanium Stabilized Stainless Steel burner. For propane (LP) models change suffix “BN” to “SX”. *Based on manufacturers rated recovery efficiency. †Dimension to top of installed mixing device. ††When tested to the industry standard residential first hour delivery procedure. GX-2 has 2" of insulation. GX-1 has 1" of insulation. Gas connections are 1⁄2". GX-2-TW-25S6BN GX-1-TW-55S6BN

G

F

H

J

Floor to Floor Floor Floor GPH 1st Hour†† Floor Floor Floor to Input Delivery Recovery to Vent Jacket Vent to T&P to Gas Space Heating Space Heating to Heater to Water Outlet Top Conn.† BTU/Hr. Rating 90°F Rise* Conn. Dia. Size Conn. Conn. Return

3" Vent Pipe

48 48

567/8 58

Approx. Shipping Depth Weight (lbs)

253/8 273/8

(LP) Propane Gas Inputs

GX-2-TW25S6SX GX-1-TW55S6SX

Z

4" Vent Pipe

†60 ft. †180 ft. Max. Equivalent Length Min. Equivalent Length 7 ft. 15 ft. Number 1 55 ft. 175 ft. of 2 50 ft. 170 ft. 90° Elbows 3 45 ft. 165 ft. †Consult I&O manual when using four or more elbows. Subtract 5ft. for each additional 90° elbow.

527/8 54

K

Y

GPH Rec. 90°F Rise

76,000 BTU/Hr. 78,000 BTU/Hr.

82 84

Integrated Mixing Device (Installation required for operation) Model Number

X

170 215

GX-2-TW25S6BN GX-1-TW55S6BN

X Distance Between Centers in.

in.

Z Height to Center of Pipe in.

8 8

21/2 21/2

6 6

Y Depth of Mixing Device


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.