KWICKSHOT® TANKLESS KwickShot® Tankless models are compact enough to be located at the point–of–use in office buildings, shops, garages and strip malls.
Flow Control
Thermostatic
Series Two
Series Three
Thermostatic Triple Module
Single Point (Single Phase) Model Number ES-3000-1-S-10 ES-3500-1-S-10 ES-3500-4-S-10 ES-4100-2-S-10 ES-4100-5-S-10 ES-5500-4-S-10
3.0 3.5 3.5 4.1 4.1 5.5
120 120 240 208 277 240
Rec. Wire Size 10 AWG 10 AWG 14 AWG 12 AWG 14 AWG 10 AWG
Temperature Rise °F
Current kW Rating Voltage Per Phase
0.5 GPM
25.0 Amps 29.0 Amps 14.6 Amps 19.7 Amps 14.8 Amps 22.9 Amps
41 48 48 56 56 75
Single Point
FEATURES:
Flow Control (Single Phase) Temperature Rise °F Model Number EFC-5500-4-S-10 EFC-6500-4-S-10 EFC-7500-4-S-10 EFC-8300-2-S-10 EFC-9500-4-S-10
kW Current Rating Voltage Per Phase 0.5 GPM 5.5 6.5 7.5 8.3 9.5
240 240 240 208 240
23.0 Amps 27.0 Amps 32.0 Amps 39.0 Amps 40.0 Amps
0.75 GPM
1.0 GPM
1.5 GPM
2.0 GPM
Rec. Wire Size
50 59 68 76 86
38 44 51 57 65
25 30 34 38 43
18 22 25 29 32
10 AWG 10 AWG 8 AWG 8 AWG 8 AWG
75 88 -
Thermostatic (Single Phase) Temperature Rise °F Model Number EFT-7500-4-S-10 EFT-9500-4-S-10
kW Current Rating Voltage Per Phase 0.5 GPM 7.5 9.5
240 240
32.0 Amps 40.0 Amps
0.75 GPM
1.0 GPM
1.5 GPM
2.0 GPM
Rec. Wire Size
68 86
51 65
34 43
25 32
8 AWG 8 AWG
-
Series Two Twin Heating Module (Single Phase) Temperature Rise °F Model Number EFT-19000-4-D-10
kW Current Rating Voltage Per Phase 19.0
240
2x40 Amps
1.5 GPM
2.0 GPM
2.5 GPM
3.0 GPM
4.0 GPM
Rec. Wire Size
87
65
52
43
32
8 AWG
*The unit must have 2 independent electrical circuits using correctly rated wire and 2 circuit breakers.
•
Reduced Energy Waste – Flow Switch Activates Heater Only on Demand (No Stand-by Heat Loss) 99% Efficient
•
Continuous Hot Water
•
No T&P Relief Valve Needed
•
Integral Flow Restrictor
•
Easy Installation – Mounts on Wall – No Sweat Connections
•
Ni Chrome Heating Element - Reduces Calcification
•
Space Saving Installation – Compact Size
•
Field Serviceable Element – Replaceable Cartridge Element (1-year Warranty)
•
Warranty – Heaters are Designed for Durability and Guaranteed Against Failure Due to Leaks of Heater Body/Element Assembly for a Period of 10 Years
Series Three (Single Phase) Model Number EFT-28000-4-T-10 EFT-38000-4-F-10
kW Current Rating Voltage Per Phase 28.0 38.0
240 240
3x40 Amps 4x40 Amps
1.5 GPM
2.0 GPM
Temperature Rise °F 2.5 3.0 4.0 GPM GPM GPM
5.0 GPM
6.0 GPM
Rec. Wire Size
-
96 130
76 104
52
43
8 AWG 8 AWG
65 86
50 65
If the unit is connected to a 460/265 three phase system, the above outputs will be reduced by 8.5%.
Thermostatic Triple Module (Three Phase) Model Number EFTR-18000-2-T-10 EFTR-24000-2-T-10 EFTR-18000-6-T-10 EFTR-24000-6-T-10 EFTR-32000-6-T-10
Temperature Rise °F kW Current Rating Voltage Per Phase 1.5 GPM 2.0 GPM 2.5 GPM 3.0 GPM 3.5 GPM 4.0 GPM 18.0 24.0 18.0 24.0 32.0
208 208 480Y* 480Y* 480Y*
50.0 Amps 67.0 Amps 21.7 Amps 28.9 Amps 38.5 Amps
82 82 -
61 82 61 82 -
49 65 49 65 87
41 54 41 54 73
35 47 35 47 62
32 41 32 41 55
Rec. Wire Size 10 AWG 10 AWG 10 AWG 10 AWG 8 AWG
These models are not recommended for sanitation purposes.
VISIT WWW.BRADFORDWHITE.COM FOR THE RIGHTSPEC® SIZING AND CROSS REFERENCE PROGRAM.