QMD10/2,2kW-A-SMP Direct start Control panel for 1 single-phase electric pump up to 2,2kW with Ammetric protection and Preset Mother Board

CONTROL PANELS FOR 1 230V SINGLE-PHASE ELECTRIC PUMP WITH AMMETRIC PROTECTION AND PRESET MOTHERBOARD The panels equipped with pre-configured motherboards offer maximum application flexibility, not only for present requirements, but for future needs too, as the standard board is already configured for use with the modules included in the catalogue (alarms, level gauges, exchangers, etc.). The addition of modules is already envisaged at the motherboard design stage and the modules are powered by the same board. This means several modules can be combined, with considerable financial savings and a much more compact design than when different items of complementary, self-powered equipment are used together

CONNECTION DIAGRAM

P

COM

RUN

START

A

B

GENERAL CHARACTERISTICS:

– Electronic control panel; – Power supply ~ 50/60Hz 230V±10%; – Very low voltage inputs for external control from pressure switch or float switch; – Very low voltage inputs for pressure switch or min. level float against dry run or too full; – Selector for pressure switch or minimum level float (contacts N.C. or N.O.); – Mains pilot light; – Operating motor light; – Protected motor light; – Min-max water level alarm light; – Selectors for automatic-off-manual operation (the last control is not latched); – External push button for overload current protection reset; – Electronic protection with adjustable current and cut-in time; – Motor protection fuse; – Auxiliary protection fuses; – General disconnecting switch with door lock; – Thermoplastic box; – Protected to IP 50.

DESIGNED FOR FITTING OF: – MA/1-300 code 221.24 (see last pages): IIIexternal alarm control module for lack of IIIwater or motor protection cut-in; – MCL/3S-300 code 221.05 (see last pages): IIIlevel control module for 3 level sensor or 2 IIIfloats (filling or emptying); – MCL/2ST-300 code 221.04 (see last pages); control module for 2 timed level sensors (filling or emptying); – KCC/…: capacitor connection kit (on request depending on the chosen motor see last IIIpages); – MR/ED-120”-400 code 221.12 (see last IIIpages): delayed module for switch on and switch off of the electric pump adjustable from 0 to 120”.

PROTECTED TO IP55 (OPTIONAL): – Switch cover, code 644.344; – Push button cover, code 644.345.

ELECTRONIC SPARE PARTS – Mother board SMPM1A, code 223.36; – Synoptic panel for IP55, code 316.03.

N.B.: The modules MCL/3S and MCL/2ST have substitutional function of the pressure switch or minimum level float.

OPERATING CONDITIONS – Ambient temperature –5 to +40°C; – Relative moisture 50% with a max temperature of 40°C.

TECHNICAL DATA AND OPERATING POWERS MODEL

CODE

APPROX POWER AT 230V kW

APPROX POWER AT 230V Hp

CURRENT ABSORPTION (A) MIN

CURRENT ABSORPTION (A) MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

QMD10/2,2kW-A-SMP

233.25

0,37 - 2,2

0,5 - 3

2

18

1,7

280

200

130