Clean Room™ OPTIMA® Clean Room ULTIMA®
Up to 80%
armstrong.com/greengenie armstrong.com/greengenie
LEED® Credits
LEED for Schools
Square Lay-in, Tegular
Energy Waste Recycled Local Renewable Daylight
Acoustics Low Emitting
smooth texture
4
Mgmt
Content Materials Materials
4
& Views
4 4 Location Dependent
4
or CHPS
4
4
$$$$$ Visual Selection
Performance Selection
Dots represent highest level of performance.
UL Classified
Suspension Acoustics Fire Light Sag Detail Dwg. Item Dimensions NRC CAC AC Rating Reflect Resist Pgs. 226-228 No.
Edge Profile
Anti- Durable Recycle Microbial Program
Clean Room OPTIMA (see Health Zone™ Optima, Items 3114, 3115, 3214, 3215, Pgs. 113-114) 15/16" 2 3114 2' x 2' x 1" 0.95 N/A 190 Class A 0.86 HumiGuard+ Inherent Wash Scrub Water Impact Scratch Soil Yes Square Lay-in Repel l l l l l l l l l l l l Ultima Plank ShipLap Long Edge Detail
gled Tegular
Lay-in Square
Ultima Plank ShipLap K2C212, Short2
Ultima Plank ShipLap Long Edge Detail
3115
2' x 4' x 1" 0.95 N/A
190
l
l
l
12, 2 3314 2' x 2' x 1-1/2" 0.95 29 190 Class A 0.86 l l l l l l l l l l
l
–
l
–
l
l
l
12, 2 3215 2' x 4' x 1" 0.95 N/A 190 Class A 0.86 l l l l l l l l l l
l
l
l
–
l
–
Classic Step Tegular
15/16" Chamford Tegular 12, 2 Cirrus Profiles Chamfered
Ultima Plank ShipLap 1" 0.95 Long Edge Detail
Ultima Plank ShipLap N/A 190 Class Beveled Tegular Short
3214 2' x 2' x Square Tegular l l
15/16" Square Tegular
Lay-in
A
15/16 Classic Step Tegular A 0.86 ~8-ID (99) (drw 10) l
l
l
l
l
l
l
C
12, 2 3317 2' x 4' x 1-1/2" 0.95 29 190 Class A 0.86 l l l l l l l l l l Angled Tegular Ultima Plank ShipLap Ultima Plank ShipLap 15/16" D
Long Edge Detail
K2C2 Short
Clean Room ULTIMA (see Health Zone Ultima, Items 1935 and 1937, Pg. 173)
ered Tegular s Chamfered
led Tegular
l
A B C D A B C D 15/16" 2 1935 2' x 2' x 3/4" 0.70 35 N/A Class A 0.86 HumiGuard+ Inherent Wash Scrub Water Impact 15/16" Vector 15/16" Vector C&D Concealed Linear Cubic 9/16" Wrapped Linear and Square Lay-in Repell. A B C D Square Edge K4C4 Beveled Crossgate Mixed Corner “B” 15/16" Vector 15/16" Vector C & D l l l l l l l (Flumes, Graphis Linear Corner & Dots & Squares) Classic Step Tegular Ultima Plank ShipLap Ultima Plank ShipLap 15/16 Classic Step Tegular 15/16" Chamford Tegular ~8-ID (99) (drw 10) Long 15/16" Edge Detail Tegular Short CirrusSquare ProfilesLay-in Chamfered Ultima Plank ShipLap Ultima Plank ShipLap 9/16" Angled Tegular Angled Tegular Beveled
r Cubic Crossgate
c Graphis ubic
B
l
9/16" Wrapped Tegular Graphis Linear 12,Wrapped 2 3316 2' x 2' x 1-1/2" 0.95 29 190 Class A 0.86 CubicTegular 15/16" Beveled 9/16" Square Cut Tegular 15/16" Square Tegular 9/16"lWrapped Tegular l l l l l l l l l and Graphis Wrapped Linear and Cubic
9/16" Beveled Tegular 9/16" Angled Tegular
l
12, 2 3315 2' x 4' x 1-1/2" 0.95 29 190 Class A 0.86 Ultima Plank 15/16 Classic Step Tegular l l l l l l l l l l ShipLap ~8-ID (99) (drw 10) Beveled Tegular Short
9/16" Chamfered Tegular 15/16" Cirrus Profiles Chamfered
are Cut Tegular
Class A 0.86
l l l l Angled Tegular Ultima Plank l ShipLap 9/16" 15/16" Angled Tegular Ultima Plank ShipLap l Long Edge Detail K2C2 Short
p Tegular
Scratch Soil Yes
l
l
Long Edge Detail Short 15/16" 12, 2A 1937 2' x 2' x 3/4" 0.70 35 K2C2N/A Class A 0.86 l l l l l l l l Beveled Tegular
l
l
Concealed Soft Look Radiused Tegular Concealed Beveled K4C4 15/16" Beveled Tegular
Tongue and Groove 9/16" Square Cut Tegular
9/16" Chamfered Tegular Cirrus Profiles Chamfered
9/16" Cubic Graphis 15/16"NeoCubic Square Tegular Classic Step Tegular
15/16" Chamford Tegular Cirrus Profiles Chamfered
Suspension Systems
Concealed 9/16" Soft LookWrapped RadiusedTegular Tegular Graphis Wrapped Linear Ultima Plank and ShipLap Ultima Plank ShipLap Cubic Long Edge Detail Beveled Tegular Short
l
15/16 Classic Step Tegular ~8-ID (99) (drw 10)
15/16" Prelude ®
M ineral F iber & F iberglass
d Linear and rner “B” s Linear Corner Squares)
K4C4
Recycled Content:
ush Tegular dges
Concealed 9/16" Flush 9/16" Beveled Tegular Square EdgeTegular K4C4 Ledges
A
B
C
D
Clean Room
Prelude Linear CubicPlus A B C D 15/16" Flush Tegular . 15/16" Square Tegular 15/16" Beveled Tegular 9/16" Square Cut Tegular Beveled Crossgate 15/16" Vector 15/16" Vector C & D AL Prelude Ledges Plus XL ®
Beveled Tegular Clean Room Grid
9/16" Wrapped Tegular 2.A
Graphis Wrapped Linear and Cubic
Physical Data Material 3114, 3115, 3214, 3215 – Fiberglass with DuraBrite ® acoustically transparent membrane 1935,Linear 1937 mineral fiber withLinear DuraBrite 9/16" Wrapped and – Wet formed Concealed Cubic transparent water-repellent membrane Corner “B” Square Edge K4C4 Beveled Crossgate TongueMixed andacoustically Groove 9/16" Cubic Graphis Concealed
(Flumes, Graphis Linear Corner Surface & Dots & Squares) Finish
NeoCubic
Soft Look Radiused Tegular
DuraBrite with factory-applied latex paint Fire Performance ASTM E84 and CAN/ULC S102 surface burning characteristics. Flame Spread Index 25 or less. Smoke Developed Index 50 or less. (UL labeled)
ASTM Concealed Beveled K4C4 E1264 Classification Tongue and Groove 15/16" Flush Tegular 3114, 3115, 3214, 3215, 3314, LedgesXII, Form 2, Pattern E Type
9/16" Cubic Graphis
3315, 3316, 3317 – NeoCubic
1935, 1937 – Type IV, Form 2, Pattern E Fire Class A
Sag Resistance HumiGuard ® Plus – superior resistance to sagging in high humidity conditions up to, but not including, standing water and outdoor applications. 9/16" Flush Tegular Ledges
151
15/16" Flush Tegular Ledges
A
VOC/Formaldehyde Emissions B Dept. of C D Meets CA Health Services Standard Practice for the testing of VOC Emissions and is listed on CHPS High Performance Products Database for Low-Emitting Materials. A B C D 15/16" Vector
15/16" Vector C & D
Anti Mold/Mildew & Bacteria 3114, 3115, 3214, 3215, 3314, 3315, 3316, 3317 – Fiberglass substrate is inherently resistant to the growth of mold, mildew, and bacteria. 1935, 1937 – BioBlock ® Plus contains an anti-microbial treatment and provides guaranteed resistance against growth of mold/mildew and Gram-positive and Gram-negative odor/stain-causing bacteria for 30 years.
ConcealedValue Insulation Soft Look Radiused 3114, 3115,Tegular 3214,
3215, 3314, 3315, 3316, 3317 – R Factor – 4.0 (BTU units) R Factor – 0.70 (Watts units) 1935, 1937 – R Factor – 2.2 (BTU units) R Factor – 0.39 (Watts units) 30-Year Performance Guarantee & Warranty Information See warranty details at armstrong.com/warranty Application Considerations Clean Room Optima (Health Zone Optima) For Clean Room installations with Clean Room Optima, use full-size panels with Clean Room grid.
TechLineSM 877 ARmSTRONG
armstrong.com/ceilings (search: clean room)
Clean Room Ultima (Health Zone Ultima) For Clean Room installations with Clean Room Ultima, use full-size panels (items 1935 and 1937) with Clean Room grid. Clean Room Ultima has been tested to withstand 500 wash and scrub cycles. Cleaning Recommendations To clean panel, use a clean, white cloth with water or a mild detergent and wipe surface. To disinfect panel, lightly spray surface and wipe clean with a clean, white cloth. Acceptable colorless disinfectants include: • Sodium hypochlorite • Isopropyl alcohol • Hydrogen peroxide • Quaternary ammonium Weight; Square Feet/Carton 3114, 3115, 3214, 3215 – 0.45 lbs/SF; 96 SF/ctn 1935, 1937 – 1.08 lbs/SF; 48 SF/ctn 3314, 3315, 3316, 3317 – 0.78 lbs/SF; 64 SF/ctn Note: For assistance on proper Clean Room installation, contact TechLine at 1 877 ARMSTRONG. For Clean Room installations, use Clean Room Optima or Clean Room Ultima only with Armstrong Clean Room Grid Systems.