Catalogo Armstrong

Page 152

Clean Room™ OPTIMA® Clean Room ULTIMA®

Up to 80%

armstrong.com/greengenie armstrong.com/greengenie

LEED® Credits

LEED for Schools

Square Lay-in, Tegular

Energy Waste Recycled Local Renewable Daylight

Acoustics Low Emitting

smooth texture

4

Mgmt

Content Materials Materials

4

& Views

4 4 Location Dependent

4

or CHPS

4

4

$$$$$ Visual Selection

Performance Selection

Dots represent highest level of performance.

UL Classified

Suspension Acoustics Fire Light Sag Detail Dwg. Item Dimensions NRC CAC AC Rating Reflect Resist Pgs. 226-228 No.

Edge Profile

Anti- Durable Recycle Microbial Program

Clean Room OPTIMA (see Health Zone™ Optima, Items 3114, 3115, 3214, 3215, Pgs. 113-114) 15/16" 2 3114 2' x 2' x 1" 0.95 N/A 190 Class A 0.86 HumiGuard+ Inherent Wash Scrub Water Impact Scratch Soil Yes Square Lay-in Repel l l l l l l l l l l l l Ultima Plank ShipLap Long Edge Detail

gled Tegular

Lay-in Square

Ultima Plank ShipLap K2C212, Short2

Ultima Plank ShipLap Long Edge Detail

3115

2' x 4' x 1" 0.95 N/A

190

l

l

l

12, 2 3314 2' x 2' x 1-1/2" 0.95 29 190 Class A 0.86 l l l l l l l l l l

l

l

l

l

l

12, 2 3215 2' x 4' x 1" 0.95 N/A 190 Class A 0.86 l l l l l l l l l l

l

l

l

l

Classic Step Tegular

15/16" Chamford Tegular 12, 2 Cirrus Profiles Chamfered

Ultima Plank ShipLap 1" 0.95 Long Edge Detail

Ultima Plank ShipLap N/A 190 Class Beveled Tegular Short

3214 2' x 2' x Square Tegular l l

15/16" Square Tegular

Lay-in

A

15/16 Classic Step Tegular A 0.86 ~8-ID (99) (drw 10) l

l

l

l

l

l

l

C

12, 2 3317 2' x 4' x 1-1/2" 0.95 29 190 Class A 0.86 l l l l l l l l l l Angled Tegular Ultima Plank ShipLap Ultima Plank ShipLap 15/16" D

Long Edge Detail

K2C2 Short

Clean Room ULTIMA (see Health Zone Ultima, Items 1935 and 1937, Pg. 173)

ered Tegular s Chamfered

led Tegular

l

A B C D A B C D 15/16" 2 1935 2' x 2' x 3/4" 0.70 35 N/A Class A 0.86 HumiGuard+ Inherent Wash Scrub Water Impact 15/16" Vector 15/16" Vector C&D Concealed Linear Cubic 9/16" Wrapped Linear and Square Lay-in Repell. A B C D Square Edge K4C4 Beveled Crossgate Mixed Corner “B” 15/16" Vector 15/16" Vector C & D l l l l l l l (Flumes, Graphis Linear Corner & Dots & Squares) Classic Step Tegular Ultima Plank ShipLap Ultima Plank ShipLap 15/16 Classic Step Tegular 15/16" Chamford Tegular ~8-ID (99) (drw 10) Long 15/16" Edge Detail Tegular Short CirrusSquare ProfilesLay-in Chamfered Ultima Plank ShipLap Ultima Plank ShipLap 9/16" Angled Tegular Angled Tegular Beveled

r Cubic Crossgate

c Graphis ubic

B

l

9/16" Wrapped Tegular Graphis Linear 12,Wrapped 2 3316 2' x 2' x 1-1/2" 0.95 29 190 Class A 0.86 CubicTegular 15/16" Beveled 9/16" Square Cut Tegular 15/16" Square Tegular 9/16"lWrapped Tegular l l l l l l l l l and Graphis Wrapped Linear and Cubic

9/16" Beveled Tegular 9/16" Angled Tegular

l

12, 2 3315 2' x 4' x 1-1/2" 0.95 29 190 Class A 0.86 Ultima Plank 15/16 Classic Step Tegular l l l l l l l l l l ShipLap ~8-ID (99) (drw 10) Beveled Tegular Short

9/16" Chamfered Tegular 15/16" Cirrus Profiles Chamfered

are Cut Tegular

Class A 0.86

l l l l Angled Tegular Ultima Plank l ShipLap 9/16" 15/16" Angled Tegular Ultima Plank ShipLap l Long Edge Detail K2C2 Short

p Tegular

Scratch Soil Yes

l

l

Long Edge Detail Short 15/16" 12, 2A 1937 2' x 2' x 3/4" 0.70 35 K2C2N/A Class A 0.86 l l l l l l l l Beveled Tegular

l

l

Concealed Soft Look Radiused Tegular Concealed Beveled K4C4 15/16" Beveled Tegular

Tongue and Groove 9/16" Square Cut Tegular

9/16" Chamfered Tegular Cirrus Profiles Chamfered

9/16" Cubic Graphis 15/16"NeoCubic Square Tegular Classic Step Tegular

15/16" Chamford Tegular Cirrus Profiles Chamfered

Suspension Systems

Concealed 9/16" Soft LookWrapped RadiusedTegular Tegular Graphis Wrapped Linear Ultima Plank and ShipLap Ultima Plank ShipLap Cubic Long Edge Detail Beveled Tegular Short

l

15/16 Classic Step Tegular ~8-ID (99) (drw 10)

15/16" Prelude ®

M ineral F iber & F iberglass

d Linear and rner “B” s Linear Corner Squares)

K4C4

Recycled Content:

ush Tegular dges

Concealed 9/16" Flush 9/16" Beveled Tegular Square EdgeTegular K4C4 Ledges

A

B

C

D

Clean Room

Prelude Linear CubicPlus A B C D 15/16" Flush Tegular . 15/16" Square Tegular 15/16" Beveled Tegular 9/16" Square Cut Tegular Beveled Crossgate 15/16" Vector 15/16" Vector C & D AL Prelude Ledges Plus XL ®

Beveled Tegular Clean Room Grid

9/16" Wrapped Tegular 2.A

Graphis Wrapped Linear and Cubic

Physical Data Material 3114, 3115, 3214, 3215 – Fiberglass with DuraBrite ® acoustically transparent membrane 1935,Linear 1937 mineral fiber withLinear DuraBrite 9/16" Wrapped and – Wet formed Concealed Cubic transparent water-repellent membrane Corner “B” Square Edge K4C4 Beveled Crossgate TongueMixed andacoustically Groove 9/16" Cubic Graphis Concealed

(Flumes, Graphis Linear Corner Surface & Dots & Squares) Finish

NeoCubic

Soft Look Radiused Tegular

DuraBrite with factory-applied latex paint Fire Performance ASTM E84 and CAN/ULC S102 surface burning characteristics. Flame Spread Index 25 or less. Smoke Developed Index 50 or less. (UL labeled)

ASTM Concealed Beveled K4C4 E1264 Classification Tongue and Groove 15/16" Flush Tegular 3114, 3115, 3214, 3215, 3314, LedgesXII, Form 2, Pattern E Type

9/16" Cubic Graphis

3315, 3316, 3317 – NeoCubic

1935, 1937 – Type IV, Form 2, Pattern E Fire Class A

Sag Resistance HumiGuard ® Plus – superior resistance to sagging in high humidity conditions up to, but not including, standing water and outdoor applications. 9/16" Flush Tegular Ledges

151

15/16" Flush Tegular Ledges

A

VOC/Formaldehyde Emissions B Dept. of C D Meets CA Health Services Standard Practice for the testing of VOC Emissions and is listed on CHPS High Performance Products Database for Low-Emitting Materials. A B C D 15/16" Vector

15/16" Vector C & D

Anti Mold/Mildew & Bacteria 3114, 3115, 3214, 3215, 3314, 3315, 3316, 3317 – Fiberglass substrate is inherently resistant to the growth of mold, mildew, and bacteria. 1935, 1937 – BioBlock ® Plus contains an anti-microbial treatment and provides guaranteed resistance against growth of mold/mildew and Gram-positive and Gram-negative odor/stain-causing bacteria for 30 years.

ConcealedValue Insulation Soft Look Radiused 3114, 3115,Tegular 3214,

3215, 3314, 3315, 3316, 3317 – R Factor – 4.0 (BTU units) R Factor – 0.70 (Watts units) 1935, 1937 – R Factor – 2.2 (BTU units) R Factor – 0.39 (Watts units) 30-Year Performance Guarantee & Warranty Information See warranty details at armstrong.com/warranty Application Considerations Clean Room Optima (Health Zone Optima) For Clean Room installations with Clean Room Optima, use full-size panels with Clean Room grid.

TechLineSM 877 ARmSTRONG

armstrong.com/ceilings (search: clean room)

Clean Room Ultima (Health Zone Ultima) For Clean Room installations with Clean Room Ultima, use full-size panels (items 1935 and 1937) with Clean Room grid. Clean Room Ultima has been tested to withstand 500 wash and scrub cycles. Cleaning Recommendations To clean panel, use a clean, white cloth with water or a mild detergent and wipe surface. To disinfect panel, lightly spray surface and wipe clean with a clean, white cloth. Acceptable colorless disinfectants include: • Sodium hypochlorite • Isopropyl alcohol • Hydrogen peroxide • Quaternary ammonium Weight; Square Feet/Carton 3114, 3115, 3214, 3215 – 0.45 lbs/SF; 96 SF/ctn 1935, 1937 – 1.08 lbs/SF; 48 SF/ctn 3314, 3315, 3316, 3317 – 0.78 lbs/SF; 64 SF/ctn Note: For assistance on proper Clean Room installation, contact TechLine at 1 877 ARMSTRONG. For Clean Room installations, use Clean Room Optima or Clean Room Ultima only with Armstrong Clean Room Grid Systems.