Catalogo Delixi

Page 1

Low Voltage Electrical Appliance “Right Quality, Right Price”

International Catalogue 2009


Delixi Electric: Who are we

A global company at your service Delixi was founded in 1984 in Zhejiang province with sales over 1,5BMâ‚Ź, employing more than 15000 people. Delixi created an international Joint Venture in November 2007,named Delixi Electric LTD,in order to serve you worldwide,with core LV products having the right quality at the right price. Our products are designed for Residential / Building / Energy / infrastructure and Industrial markets . Delixi Electric employs 5200 people world wide.

A reliable company serving you with reliable product Dedicated R&D center International quality control of suppliers International quality control of plants Fully automatized distribution center Network of recognized 600 distributors world wide Clear warranty policy


Reliable quality

For more details, please contact your local Delixi Electric Company. You can trust 100% our products. We offer you a 18 months warranty. During this period of time, we will replace any defected product you may have, provided the responsibility is ours.


A company to serve you where you are

We set up companies in many countries in order to deliver best in class local availability and support . Delixi Elecric China

Delixi Elecric Austral Africa

Delixi Electric South East Europe

Delixi Liushi Industrial Park,Yueqing, Zhejiang,P.R.China Post Code:325604 www.delixi-electric.com

Canon Crescan Drive , Roodekop Germiston, 1400 PO Box 13151 , Elspark, 1418 Mobile : +27 (0) 836438898 www.delixi-electric.co.za Contact : Vicky HATTINGH vicky@delixi-electric.co.za

20 Tsar Samuil str . , 1rst Floor Triaditsa Municipality Sofia Bulgaria Contact : Doychin ZAHARINOV Mobile : +359 885 750 232 doychin.zaharinov@delixi-electric-see.com

Delixi Electric Middle-East

Delixi Electric West Africa

Delixi Electric Pakistan

RAK Free trade zone PO BOX 10559 Ras El Khaima United Arab Emirates Tel : +971 ( 7 ) 244 47 27 Fax : + 971 ( 7 ) 244 27 22 delixi-electric.gulf@delanme.com Contact : Raja BHAUMIK Mobile : +971 ( 50 ) 657 1056 raja@delanme.com

1 Tunde Gaffar Close Off Adeniyi Jones Ikeja Lagos Nigeria Fax : + 234 2703941 Contact : Chidiebere NWORGU Mobile : +234 703 41 111 30 chidiebere.Nworgu@delixi-electric.com

73 / B / 3 , Race View,Jail Road, Lahore, 54000, Pakistan Tel 0092 - 42 - 7570412 / 7570443 , extension 100/103 Fax 0092 - 42 - 7570443 , extension 108 Contact : Syed Sohail IDREES Mobile : 0092 -3028489564 s.idrees@delixi-electric.com

Delixi Electric Marocco 213 Centre Yousra Rond-point d’Europe Casablanca, Maroc tel : +212 (0) 22 268 161 Fax : +212 (0) 22 491342 Contact : Hicham MOUKI Mobile : +212 (0) 61 100 849 hmouki@delixielectric.ma

Delixi Electric South East Asia

Delixi Electric Israel

P.O.Box 7567 Pejabat Post Besar Shah Alam 40720 Shah Alam Selangor Darul Ehsan Tel:03- 78809564 Fax: 03-78809540 Contact: Ellis Lee Email : ellis.lee@delixi-electric.com

Industrial park cible Hamelaha st.22 Rosh ha-aiyn Israel tel:+972546798718 Contact : Hayim COHEN email:hayim.cohen@delixi-electric.co.il

Delixi Electric Saudi Arabia

Delixi Electric Argentina

Delixi Electric Egypt

Contact : Mohkam Sheikh Mobile : +966050269801

Contact : Damian Cattaino Mobile : +54111545658952

Contact : Mohamed Nagy Mobile 20(0) 100705454


Product Panorama Power Distribution

Industry Control


Contents MCB Miniature Circuit Breakers CDB6a 18mm Miniature Circuit Breakers

1

CDB6L 18mm Miniature Circuit Breakers

3

CDB6N 18mm Miniature Circuit Breakers

5

CDB6&CDB6LE Electrical Auxiliaries

7

CDB17 Miniature Circuit Breakers

8

CDB3 Phase-neutral Circuit Breakers

10

CDB2 27mm Miniature Circuit Breakers

11

CDB5 Switch Disconnectors

13

RCBO Residual Current Operated Circuit Breakers With Integral Overcurrent Protection CDB6LE Electronic Type Residual Current Operated Circuit Breakers

15

CDB3LE Electronic Type Residual Current Operated Circuit Breakers

17

CDB2LE Electronic Type Residual Current Operated Circuit Breakers

18

CDB7LSP Electronic Type Residual Current Operated Circuit Breakers

20

RCCB Residual Current Operated Circuit Breakers Without Overcurrent Protection CDL7 Electromagnetic Type Residual Current Switches

21

Surge Protector CDY1 Surge Protective Devices

22

MCB Distribution Board CDPZ50 Distribution Box

25

Meter DDS607 Single-phase Electronic Watt-hour Meters

27

MCCB Moulded Case Circuit Breakers CDM1 Moulded Case Circuit Breakers

29

ELCB Earth-leakage Circuit Breakers CDM1L Moulded Case Circuit Breakers With Electronic Type Residual Current Operated Protection

36


ACB Air Circuit Breaker CDW7 Air Circuit Breaker

42

Contactors CDC17 AC Contactor

61

Relays CDR17 Thermal overload relays

70

Current Transformer LMK Current Transformer

73

Fuse RT16 Fuse

76

RT18 Fuse

78

Power Distribution Box JXF Power Distribution Box

80

Control Signal LD11 Series of indicator light

82

LAY3 Serie of pushbuttons

86

LAY7 Serie of pushbuttons

88

LAY8 Serie of pushbuttons

93

Pannel Meter 72 Series Pannel Meter

96

96 Series Pannel Meter

98

Voltage Stabilizer TND Voltage Stabilizer

100

Nylon Lock Nylon Cable Ties Series

102


CDB6a Standard: IEC 60898-1 IEC 60947-2 Trip Curve: B, C and D curves Breaking Capacity: 3000A

Function

CDB6a miniature circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control Isolation

Description

Technical data Rated current: 1, 3, 6, 10, 16, 20, 25, 32, 40, 50, 63 A Rated voltage: 230/400V AC Breaking capacity Rate current

Breaking capacity Icn (A)

Type

Poles

Voltage (V)

1-63A

3000

B

1P 2P, 3P, 4P 1P 2P, 3P, 4P 1P 2P, 3P, 4P

230 400 230 400 230 400

C D

Tropicalization: treatment 2 Protection degree: 2 Connection: up to 25mm2 cables Tripping curves: B curve: the magnetic release operates between 3 and 5 In C curve: the magnetic release operates between 5 and 10 In D curve: the magnetic release operates between 10 and 14 In 35 mm standard DIN rail mounting

Standard and certification IEC 60898-1 KEMA, CB

IEC 60947-2

Overall dimensions Unit:mm

Delixi Electric

1


CDB6a Standard: IEC 60898-1 IEC 60947-2 Trip Curve: B, C and D curves Breaking Capacity: 3000A Type

Rating Width (A) (in mod.of 9mm)

Reference B curve C curve

D curve

1P

1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63

CDB6a1B1 CDB6a1B3 CDB6a1B6 CDB6a1B10 CDB6a1B16 CDB6a1B20 CDB6a1B25 CDB6a1B32 CDB6a1B40 CDB6a1B50 CDB6a1B63 CDB6a2B1 CDB6a2B3 CDB6a2B6 CDB6a2B10 CDB6a2B16 CDB6a2B20 CDB6a2B25 CDB6a2B32 CDB6a2B40 CDB6a2B50 CDB6a2B63 CDB6a3B1 CDB6a3B3 CDB6a3B6 CDB6a3B10 CDB6a3B16 CDB6a3B20 CDB6a3B25 CDB6a3B32 CDB6a3B40 CDB6a3B50 CDB6a3B63 CDB6a4B1 CDB6a4B3 CDB6a4B6 CDB6a4B10 CDB6a4B16 CDB6a4B20 CDB6a4B25 CDB6a4B32 CDB6a4B40 CDB6a4B50 CDB6a4B63

CDB6a1D1 CDB6a1D3 CDB6a1D6 CDB6a1D10 CDB6a1D16 CDB6a1D20 CDB6a1D25 CDB6a1D32 CDB6a1D40 CDB6a1D50 CDB6a1D63 CDB6a2D1 CDB6a2D3 CDB6a2D6 CDB6a2D10 CDB6a2D16 CDB6a2D20 CDB6a2D25 CDB6a2D32 CDB6a2D40 CDB6a2D50 CDB6a2D63 CDB6a3D1 CDB6a3D3 CDB6a3D6 CDB6a3D10 CDB6a3D16 CDB6a3D20 CDB6a3D25 CDB6a3D32 CDB6a3D40 CDB6a3D50 CDB6a3D63 CDB6a4D1 CDB6a4D3 CDB6a4D6 CDB6a4D10 CDB6a4D16 CDB6a4D20 CDB6a4D25 CDB6a4D32 CDB6a4D40 CDB6a4D50 CDB6a4D63

2P

3P

4P

2 2 2 2 2 2 2 2 2 2 2 4 4 4 4 4 4 4 4 4 4 4 6 6 6 6 6 6 6 6 6 6 6 8 8 8 8 8 8 8 8 8 8 8

CDB6a1C1 CDB6a1C3 CDB6a1C6 CDB6a1C10 CDB6a1C16 CDB6a1C20 CDB6a1C25 CDB6a1C32 CDB6a1C40 CDB6a1C50 CDB6a1C63 CDB6a2C1 CDB6a2C3 CDB6a2C6 CDB6a2C10 CDB6a2C16 CDB6a2C20 CDB6a2C25 CDB6a2C32 CDB6a2C40 CDB6a2C50 CDB6a2C63 CDB6a3C1 CDB6a3C3 CDB6a3C6 CDB6a3C10 CDB6a3C16 CDB6a3C20 CDB6a3C25 CDB6a3C32 CDB6a3C40 CDB6a3C50 CDB6a3C63 CDB6a4C1 CDB6a4C3 CDB6a4C6 CDB6a4C10 CDB6a4C16 CDB6a4C20 CDB6a4C25 CDB6a4C32 CDB6a4C40 CDB6a4C50 CDB6a4C63

Tripping Curve

B

2

C

D

Delixi Electric


CDB6L Standard: IEC 60947-2 IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 4500A

Function

CDB6L miniature circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control Isolation

Description

Technical data Rated current: 1, 3, 6, 10, 16, 20, 25, 32, 40, 50, 63 A Rated voltage: 230/400V AC Breaking capacity: Type

Poles

Rate current

Breaking capacity Icn (A)

Voltage (V)

B

1P

1-40A 50A, 63A 1-40A 50A, 63A 1-40A 50A, 63A 1-40A 50A, 63A 1-40A 50A, 63A 1-40A 50A, 63A

4500 4500 4500 4500 4500 4500 4500 4500 4500 4500 4500 4500

230 400 230 400 230 400 230 400 230 400 230 400

2P, 3P, 4P C

1P 2P, 3P, 4P

D

1P 2P, 3P, 4P

Tropicalization: treatment 2 Protection degree: 2 Connection: up to 25mm2 cables Tripping curves: B curve: the magnetic release operates between 3 and 5 In C curve: the magnetic release operates between 5 and 10 In D curve: the magnetic release operates between 10 and 14 In 35 mm standard DIN rail mounting

Standard and certification IEC 60947-2 IEC 60898-1 KEMA, CB

Overall dimensions Unit:mm

Delixi Electric

3


CDB6L Standard: IEC 60947-2 IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 4500A Type

Rating (A)

Width Reference (in mod.of 9mm) B curve

1P

1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63

2 2 2 2 2 2 2 2 2 2 2 4 4 4 4 4 4 4 4 4 4 4 6 6 6 6 6 6 6 6 6 6 6 8 8 8 8 8 8 8 8 8 8 8

2P

3P

4P

C curve CDB6L1C1 CDB6L1C3 CDB6L1C6 CDB6L1C10 CDB6L1C16 CDB6L1C20 CDB6L1C25 CDB6L1C32 CDB6L1C40 CDB6L1C50 CDB6L1C63 CDB6L2C1 CDB6L2C3 CDB6L2C6 CDB6L2C10 CDB6L2C16 CDB6L2C20 CDB6L2C25 CDB6L2C32 CDB6L2C40 CDB6L2C50 CDB6L2C63 CDB6L3C1 CDB6L3C3 CDB6L3C6 CDB6L3C10 CDB6L3C16 CDB6L3C20 CDB6L3C25 CDB6L3C32 CDB6L3C40 CDB6L3C50 CDB6L3C63 CDB6L4C1 CDB6L4C3 CDB6L4C6 CDB6L4C10 CDB6L4C16 CDB6L4C20 CDB6L4C25 CDB6L4C32 CDB6L4C40 CDB6L4C50 CDB6L4C63

CDB6L1B1 CDB6L1B3 CDB6L1B6 CDB6L1B10 CDB6L1B16 CDB6L1B20 CDB6L1B25 CDB6L1B32 CDB6L1B40 CDB6L1B50 CDB6L1B63 CDB6L2B1 CDB6L2B3 CDB6L2B6 CDB6L2B10 CDB6L2B16 CDB6L2B20 CDB6L2B25 CDB6L2B32 CDB6L2B40 CDB6L2B50 CDB6L2B63 CDB6L3B1 CDB6L3B3 CDB6L3B6 CDB6L3B10 CDB6L3B16 CDB6L3B20 CDB6L3B25 CDB6L3B32 CDB6L3B40 CDB6L3B50 CDB6L3B63 CDB6L4B1 CDB6L4B3 CDB6L4B6 CDB6L4B10 CDB6L4B16 CDB6L4B20 CDB6L4B25 CDB6L4B32 CDB6L4B40 CDB6L4B50 CDB6L4B63

D curve CDB6L1D1 CDB6L1D3 CDB6L1D6 CDB6L1D10 CDB6L1D16 CDB6L1D20 CDB6L1D25 CDB6L1D32 CDB6L1D40 CDB6L1D50 CDB6L1D63 CDB6L2D1 CDB6L2D3 CDB6L2D6 CDB6L2D10 CDB6L2D16 CDB6L2D20 CDB6L2D25 CDB6L2D32 CDB6L2D40 CDB6L2D50 CDB6L2D63 CDB6L3D1 CDB6L3D3 CDB6L3D6 CDB6L3D10 CDB6L3D16 CDB6L3D20 CDB6L3D25 CDB6L3D32 CDB6L3D40 CDB6L3D50 CDB6L3D63 CDB6L4D1 CDB6L4D3 CDB6L4D6 CDB6L4D10 CDB6L4D16 CDB6L4D20 CDB6L4D25 CDB6L4D32 CDB6L4D40 CDB6L4D50 CDB6L4D63

Tripping Curve

B

4

C

D

Delixi Electric


CDB6N Standard: IEC 60947-2 IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 6000A

Function

CDB6N miniature circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control Isolation

Description

Technical data Rated current: 1, 3, 6, 10, 16, 20, 25, 32, 40, 50, 63 A Rated voltage: 230/400V AC Breaking capacity: Type

Poles

Rate current

Breaking capacity Icn (A)

Voltage (V)

B

1P

1-40A 50A, 63A 1-40A 50A, 63A 1-40A 50A, 63A 1-40A 50A, 63A 1-40A 50A, 63A 1-40A 50A, 63A

6000 4500 6000 4500 6000 4500 6000 4500 6000 4500 6000 4500

230 400 230 400 230 400 230 400 230 400 230 400

2P, 3P, 4P C

1P 2P, 3P, 4P

D

1P 2P, 3P, 4P

Tropicalization: treatment 2 Protection degree: 2 Connection: up to 25mm2 cables Tripping curves: B curve: the magnetic release operates between 3 and 5 In C curve: the magnetic release operates between 5 and 10 In D curve: the magnetic release operates between 10 and 14 In 35 mm standard DIN rail mounting

Standard and certification IEC 60947-2 IEC 60898-1 KEMA, CB

Overall dimensions Unit:mm

Delixi Electric

5


CDB6N Standard: IEC 60947-2 IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 6000A Type

Rating Width Reference (A) (in mod.of 9mm) B curve

C curve

D curve

1P

1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63

CDB6N1C1 CDB6N1C3 CDB6N1C6 CDB6N1C10 CDB6N1C16 CDB6N1C20 CDB6N1C25 CDB6N1C32 CDB6N1C40 CDB6N1C50 CDB6N1C63 CDB6N2C1 CDB6N2C3 CDB6N2C6 CDB6N2C10 CDB6N2C16 CDB6N2C20 CDB6N2C25 CDB6N2C32 CDB6N2C40 CDB6N2C50 CDB6N2C63 CDB6N3C1 CDB6N3C3 CDB6N3C6 CDB6N3C10 CDB6N3C16 CDB6N3C20 CDB6N3C25 CDB6N3C32 CDB6N3C40 CDB6N3C50 CDB6N3C63 CDB6N4C1 CDB6N4C3 CDB6N4C6 CDB6N4C10 CDB6N4C16 CDB6N4C20 CDB6N4C25 CDB6N4C32 CDB6N4C40 CDB6N4C50 CDB6N4C63

CDB6N1D1 CDB6N1D3 CDB6N1D6 CDB6N1D10 CDB6N1D16 CDB6N1D20 CDB6N1D25 CDB6N1D32 CDB6N1D40 CDB6N1D50 CDB6N1D63 CDB6N2D1 CDB6N2D3 CDB6N2D6 CDB6N2D10 CDB6N2D16 CDB6N2D20 CDB6N2D25 CDB6N2D32 CDB6N2D40 CDB6N2D50 CDB6N2D63 CDB6N3D1 CDB6N3D3 CDB6N3D6 CDB6N3D10 CDB6N3D16 CDB6N3D20 CDB6N3D25 CDB6N3D32 CDB6N3D40 CDB6N3D50 CDB6N3D63 CDB6N4D1 CDB6N4D3 CDB6N4D6 CDB6N4D10 CDB6N4D16 CDB6N4D20 CDB6N4D25 CDB6N4D32 CDB6N4D40 CDB6N4D50 CDB6N4D63

2P

3P

4P

2 2 2 2 2 2 2 2 2 2 2 4 4 4 4 4 4 4 4 4 4 4 6 6 6 6 6 6 6 6 6 6 6 8 8 8 8 8 8 8 8 8 8 8

CDB6N1B1 CDB6N1B3 CDB6N1B6 CDB6N1B10 CDB6N1B16 CDB6N1B20 CDB6N1B25 CDB6N1B32 CDB6N1B40 CDB6N1B50 CDB6N1B63 CDB6N2B1 CDB6N2B3 CDB6N2B6 CDB6N2B10 CDB6N2B16 CDB6N2B20 CDB6N2B25 CDB6N2B32 CDB6N2B40 CDB6N2B50 CDB6N2B63 CDB6N3B1 CDB6N3B3 CDB6N3B6 CDB6N3B10 CDB6N3B16 CDB6N3B20 CDB6N3B25 CDB6N3B32 CDB6N3B40 CDB6N3B50 CDB6N3B63 CDB6N4B1 CDB6N4B3 CDB6N4B6 CDB6N4B10 CDB6N4B16 CDB6N4B20 CDB6N4B25 CDB6N4B32 CDB6N4B40 CDB6N4B50 CDB6N4B63

Tripping Curve

B

6

C

D

Delixi Electric


CDB6&CDB6LE Electrical Auxiliaries

Type

Voltage

Reference

OF

AC230

CDB6OF230AC

AC400

CDB6OF400AC

DC24

CDB6OF24DC

DC48

CDB6OF48DC

DC110

CDB6OF110DC

DC220

CDB6OF220DC

AC230

CDB6SD230AC

AC400

CDB6SD400AC

DC24

CDB6SD24DC

DC48

CDB6SD48DC

DC110

CDB6SD110DC

DC220

CDB6SD220DC

AC230

CDB6MX230AC

DC24

CDB6MX24AC

SD

MX+OF*

OF contact auxiliary

SD fault-indicating switch

MX+OF shunt trip release

Delixi Electric

7


CDB17 Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 6000A

Function

CDB17N miniature circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control Isolation

Description

Technical data Rated current: 1, 3, 6, 10, 16, 20, 25, 32, 40, 50, 63 A Rated voltage: 230/400V AC Breaking capacity Rate current

Breaking capacity Icn (A)

Type

Poles

Voltage (V)

1-63A

6000

B

1P 2P,3P,4P 1P 2P,3P,4P 1P 2P,3P,4P

230 400 230 400 230 400

C D

Tropicalization: treatment 2 Protection degree: 2 Connection: up to 25mm 2 cables Tripping curves: B curve: the magnetic release operates between 3 and 5 In C curve: the magnetic release operates between 5 and 10 In D curve: the magnetic release operates between 10 and 14 In 35 mm standard DIN rail mounting

Standard and certification IEC 60898-1 KEMA, CB, CE

Overall dimensions Unit:mm

8

Delixi Electric


CDB17 Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 6000A Type

Rating (A)

Width Reference (in mod.of 9mm) B curve

1P

1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63

2 2 2 2 2 2 2 2 2 2 2 4 4 4 4 4 4 4 4 4 4 4 6 6 6 6 6 6 6 6 6 6 6 8 8 8 8 8 8 8 8 8 8 8

2P

3P

4P

C curve CDB17N1C1 CDB17N1C3 CDB17N1C6 CDB17N1C10 CDB17N1C16 CDB17N1C20 CDB17N1C25 CDB17N1C32 CDB17N1C40 CDB17N1C50 CDB17N1C63 CDB17N2C1 CDB17N2C3 CDB17N2C6 CDB17N2C10 CDB17N2C16 CDB17N2C20 CDB17N2C25 CDB17N2C32 CDB17N2C40 CDB17N2C50 CDB17N2C63 CDB17N3C1 CDB17N3C3 CDB17N3C6 CDB17N3C10 CDB17N3C16 CDB17N3C20 CDB17N3C25 CDB17N3C32 CDB17N3C40 CDB17N3C50 CDB17N3C63 CDB17N4C1 CDB17N4C3 CDB17N4C6 CDB17N4C10 CDB17N4C16 CDB17N4C20 CDB17N4C25 CDB17N4C32 CDB17N4C40 CDB17N4C50 CDB17N4C63

CDB17N1B1 CDB17N1B3 CDB17N1B6 CDB17N1B10 CDB17N1B16 CDB17N1B20 CDB17N1B25 CDB17N1B32 CDB17N1B40 CDB17N1B50 CDB17N1B63 CDB17N2B1 CDB17N2B3 CDB17N2B6 CDB17N2B10 CDB17N2B16 CDB17N2B20 CDB17N2B25 CDB17N2B32 CDB17N2B40 CDB17N2B50 CDB17N2B63 CDB17N3B1 CDB17N3B3 CDB17N3B6 CDB17N3B10 CDB17N3B16 CDB17N3B20 CDB17N3B25 CDB17N3B32 CDB17N3B40 CDB17N3B50 CDB17N3B63 CDB17N4B1 CDB17N4B3 CDB17N4B6 CDB17N4B10 CDB17N4B16 CDB17N4B20 CDB17N4B25 CDB17N4B32 CDB17N4B40 CDB17N4B50 CDB17N4B63

D curve CDB17N1D1 CDB17N1D3 CDB17N1D6 CDB17N1D10 CDB17N1D16 CDB17N1D20 CDB17N1D25 CDB17N1D32 CDB17N1D40 CDB17N1D50 CDB17N1D63 CDB17N2D1 CDB17N2D3 CDB17N2D6 CDB17N2D10 CDB17N2D16 CDB17N2D20 CDB17N2D25 CDB17N2D32 CDB17N2D40 CDB17N2D50 CDB17N2D63 CDB17N3D1 CDB17N3D3 CDB17N3D6 CDB17N3D10 CDB17N3D16 CDB17N3D20 CDB17N3D25 CDB17N3D32 CDB17N3D40 CDB17N3D50 CDB17N3D63 CDB17N4D1 CDB17N4D3 CDB17N4D6 CDB17N4D10 CDB17N4D16 CDB17N4D20 CDB17N4D25 CDB17N4D32 CDB17N4D40 CDB17N4D50 CDB17N4D63

Tripping Curve

B

Delixi Electric

C

D

9


CDB3 Standard: IEC 60898-1 Trip Curve: C and D curves Breaking Capacity: 3000A

Function

CDB3 phase-neutral circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control Isolation

Description

Technical data Rated current: 6, 10, 16, 20, 25, 32A Rated voltage: 230V AC Breaking capacity: 3 kA Tripping curves: C curve: the magnetic release operates between 5 and 10 In D curve: the magnetic release operates between 10 and 14 In Tropicalization: treatment 2 Protection degree: 2 Connection Up to 16mm2 cables 35mm standard DIN rail mounting

Standard and certification IEC 60898-1 Type

Rating (A)

Width (in mod.of 9mm)

Reference C curve

D curve

1P+N

6 10 16 20 25 32

2 2 2 2 2 2

CDB3a5C6 CDB3a5C10 CDB3a5C16 CDB3a5C20 CDB3a5C25 CDB3a5C32

CDB3a5D6 CDB3a5D10 CDB3a5D16 CDB3a5D20 CDB3a5D25 CDB3a5D32

Overall dimensions

Tripping Curve

C

10

D

Delixi Electric


CDB2 Standard: IEC 60947-2 Trip Curve: C and D curves Breaking Capacity: 10000A

Function

CDB2 miniature circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control Isolation

Description

Technical data Rated current: 63, 80, 100, 125 A Rated voltage : 230/400V AC Breaking capacity Rating (A)

Type

Voltage (V)

Breaking capacity (kA)

63 ~125

1P 2/3/4P

230 400

10 10

Tripping curves: C curve: the magnetic release operates between 5 and 10 In D curve: the magnetic release operates between 10 and 14 In Mechanical durability: 8,500 (In 100A) / 7,000 (In=125A) Electrical durability: 1,500 (In 100A) / 1,000 (In=125A) Tropicalization: treatment 2 Protection degree: 2 Connection Up to 50 mm 2 cables 35mm standard DIN rail mounting Closed position indication

Standard and certification IEC 60947-2 SEMKO, CE

Overall dimensions Unit:mm

Delixi Electric

11


CDB2 Standard: IEC 60947-2 Trip Curve: C and D curves Breaking Capacity: 10000A Type

Rating (A)

Width (in mod.of 9mm)

Reference C curve

D curve

1P

63 80 100 125

3 3 3 3

CDB2H1C63 CDB2H1C80 CDB2H1C100 CDB2H1C125

CDB2H1D63 CDB2H1D80 CDB2H1D100 CDB2H1D125

2P

63 80 100 125

6 6 6 6

CDB2H2C63 CDB2H2C80 CDB2H2C100 CDB2H2C125

CDB2H2D63 CDB2H2D80 CDB2H2D100 CDB2H2D125

3P

63 80 100 125

9 9 9 9

CDB2H3C63 CDB2H3C80 CDB2H3C100 CDB2H3C125

CDB2H3D63 CDB2H3D80 CDB2H3D100 CDB2H3D125

4P

63 80 100 125

12 12 12 12

CDB2H4C63 CDB2H4C80 CDB2H4C100 CDB2H4C125

CDB2H4D63 CDB2H4D80 CDB2H4D100 CDB2H4D125

Tripping Curve

C

12

D

Delixi Electric


CDB5 Standard: IEC 60947-3

Function

CDB5 switch disconnectors combine the following functions: Making and breaking normal load circuits Isolation

Description

Technical data Rated current: 20, 32, 63, 100 A Rated voltage: 230/400V AC Mechanical durability: 8500 Electrical durability: 1500 Short-time withstand capacity for 1 s: 12Ie Tropicalization: treatment 2 Protection degree: 2 Connection Up to 35 mm2 cables 35 mm standard DIN rail mounting Isolation with positive break indication

Standard and certification IEC 60947-3

Overall dimensions Unit:mm

Delixi Electric

13


CDB5 Standard: IEC 60947-3

14

Type

Rating (A)

Voltage (V AC)

Width (in mod.of 9mm)

Reference

1P

20 32 63 100

230 230 230 230

2 2 2 2

CDB5120 CDB5132 CDB5163 CDB51100

2P

20 32 63 100

400 400 400 400

4 4 4 4

CDB5220 CDB5232 CDB5263 CDB52100

3P

20 32 63 100

400 400 400 400

6 6 6 6

CDB5320 CDB5332 CDB5363 CDB53100

4P

20 32 63 100

400 400 400 400

8 8 8 8

CDB5420 CDB5432 CDB5463 CDB54100

Delixi Electric


CDB6LE Standard: IEC 61009 Trip Curve: C and D curves Breaking Capacity: 3000A Sensitivity: 30mA

Function

CDB6LE electronic type residual current operated circuit breakers combine the following functions: Overload protection Protection against short-circuit current Protection for users against indirect contact Additional protection for users against direct contacts (30mA) Protection for electrical installations against insulation faults (fire hazard, etc) Isolation

Description

Technical data Rated current: 6, 10, 16, 20, 25, 32, 40, 50, 60A Rated voltage: 230V AC for 1P+N/2P, 400V AC for 3P/3P+N/4P Sensitivity: 30 mA Tropicalization: treatment 2 Protection degree: 2 Connection Up to 16 mm2 cables Tripping curves: C curve: the magnetic release operates between 5 and 10 In D curve: the magnetic release operates between 10 and 14 In Mechanical indication of the earth fault on the front face by a black mechanical indicator 35 mm standard DIN rail mounting.

Standard and certification IEC 61009

Overall dimensions

CDB6LE-32

CDB6LE-63

Delixi Electric

15


CDB6LE Standard: IEC 61009 Trip Curve: C and D curves Breaking Capacity: 3000A Sensitivity: 30mA Type

Voltage (V)

Sensitivity Rating (mA) (A)

1P+N

230

30

2P

230

30

3P

400

30

3P+N

400

30

4P

400

30

6 10 16 20 25 32 40 50 60 6 10 16 20 25 32 40 50 60 6 10 16 20 25 32 40 50 60 6 10 16 20 25 32 40 50 60 6 10 16 20 25 32 40 50 60

Width Reference (in mod.of 9mm) C curve 5 5 5 5 5 5 6 6 6 7 7 7 7 7 7 8 8 8 10 10 10 10 10 10 12 12 12 11 11 11 11 11 11 14 14 14 13 13 13 13 13 13 16 16 16

CDB6LEa1C6S CDB6LLEa1C10S CDB6LEa1C16S CDB6LEa1C20S CDB6LEa1C25S CDB6LEa1C32S CDB6LEa1C40S CDB6LEa1C50S CDB6LEa1C60S CDB6LEa2C6S CDB6LEa2C10S CDB6LEa2C16S CDB6LEa2C20S CDB6LEa2C25S CDB6LEa2C32S CDB6LEa2C40S CDB6LEa2C50S CDB6LEa2C60S CDB6LEa3C6S CDB6LEa3C10S CDB6LEa3C16S CDB6LEa3C20S CDB6LEa3C25S CDB6LEa3C32S CDB6LEa3C40S CDB6LEa3C50S CDB6LEa3C60S CDB6LEa4C6S CDB6LEa4C10S CDB6LEa4C16S CDB6LEa4C20S CDB6LEa4C25S CDB6LEa4C32S CDB6LEa4C40S CDB6LEa4C50S CDB6LEa4C60S CDB6LEa6C6S CDB6LEa6C10S CDB6LEa6C16S CDB6LEa6C20S CDB6LEa6C25S CDB6LEa6C32S CDB6LEa6C40S CDB6LEa6C50S CDB6LEa6C60S

D curve CDB6LEa1D6S CDB6LEa1D10S CDB6LEa1D16S CDB6LEa1D20S CDB6LEa1D25S CDB6LEa1D32S CDB6LEa1D40S CDB6LEa1D50S CDB6LEa1D60S CDB6LEa2D6S CDB6LEa2D10S CDB6LEa2D16S CDB6LEa2D20S CDB6LEa2D25S CDB6LEa2D32S CDB6LEa2D40S CDB6LEa2D50S CDB6LEa2D60S CDB6LEa3D6S CDB6LEa3D10S CDB6LEa3D16S CDB6LEa3D20S CDB6LEa3D25S CDB6LEa3D32S CDB6LEa3D40S CDB6LEa3D50S CDB6LEa3D60S CDB6LEa4D6S CDB6LEa4D10S CDB6LEa4D16S CDB6LEa4D20S CDB6LEa4D25S CDB6LEa4D32S CDB6LEa4D40S CDB6LEa4D50S CDB6LEa4D60S CDB6LEa6D6S CDB6LEa6D10S CDB6LEa6D16S CDB6LEa6D20S CDB6LEa6D25S CDB6LEa6D32S CDB6LEa6D40S CDB6LEa6D50S CDB6LEa6D60S

Tripping Curve

B

16

C

D

Delixi Electric


CDB3LE Standard: IEC 61009 Trip Curve: C curves Breaking Capacity: 3000A Sensitivity: 30mA

Function

CDB3LE electronic type residual current operated circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Protection of users against indirect contact Additional protection for users against direct contacts (30mA) Protection of electrical installations against insulation faults (fire hazard, etc) Isolation

Description

Technical data Rated current: 6, 10, 16, 20, 25, 32, 40A Rated voltage: 230V AC Breaking capacity: 3kA Sensitivity: 30mA Tripping curve: C curve: the magnetic release operates between 5 and 10 In Tropicalization: treatment 2 Protection degree: 2 Connection Up to 6 mm2 cables Mechanical indication of the earth fault on the front face by a red mechanical indicator 35 mm standard DIN rail mounting

Standard and certification IEC 61009 Type

Sensltivity(mA) Width (in mod.of 9mm) 4

1P+N 30

Rating(A)

Reference C curve

6 10 16 20 25 32 40

CDB3LEa5C6S CDB3LEa5C10S CDB3LEa5C16S CDB3LEa5C20S CDB3LEa5C25S CDB3LEa5C32S CDB3LEa5C40S

Overall dimensions Unit:mm

Tripping Curve

C

Delixi Electric

17


CDB2LE Standard: IEC 60947-2 Trip Curve: C and D curves Breaking Capacity: 10000A Sensitivity: 100mA, 300mA

Function

CDB2LE electronic type residual current operated circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Protection of users against indirect contact Protection of electrical installations against insulation faults (fire hazard, etc) Isolation

Description

Technical data Rated current: 63A, 80A,100A Rated voltage: 230V for 1P+N; 400V for 2P/3P/3P+N/4P Sensitivity: 100mA,300mA Rated ultimate short-circuit breaking capacity (Icu): 10,000A Rated service short-circuit breaking capacity (Ics): 7,500A Tripping curves: C curve: the magnetic release operates between 5 and 10 In D curve: the magnetic release operates between 10 and 14 In 2 types of residual current tripping are available: Instantaneous Time-delay with a maximum delay time of 0.2 s Tropicalization: treatment 2 Protection degree: 2 Connection Up to 50 mm2 cables Mechanical indication of the earth fault on the front face by a black mechanical indicator Closed position indication 35 mm standard DIN rail mounting

Standard and certification IEC 60947-2

Overall dimensions Unit:mm

18

Delixi Electric


CDB2LE Standard: IEC 60947-2 Trip Curve: C and D curves Breaking Capacity: 10000A Sensitivity: 100mA, 300mA Type

Width Sensitivity Rating (in mod.of 9mm) (mA) (A)

Reference C curve

D curve

1P+N 6

100 100 100 300 300 300

63 80 100 63 80 100

CDB2LEH1C63Y CDB2LEH1C80Y CDB2LEH1C100Y CDB2LEH1C63T CDB2LEH1C80T CDB2LEH1C100T

CDB2LEH1D63Y CDB2LEH1D80Y CDB2LEH1D100Y CDB2LEH1D63T CDB2LEH1D80T CDB2LEH1D100T

2P

9

100 100 100 300 300 300

63 80 100 63 80 100

CDB2LEH2C63Y CDB2LEH2C80Y CDB2LEH2C100Y CDB2LEH2C63T CDB2LEH2C80T CDB2LEH2C100T

CDB2LEH2D63Y CDB2LEH2D80Y CDB2LEH2D100Y CDB2LEH2D63T CDB2LEH2D80T CDB2LEH2D100T

3P

12

100 100 100 300 300 300

63 80 100 63 80 100

CDB2LEH3C63Y CDB2LEH3C80Y CDB2LEH3C100Y CDB2LEH3C63T CDB2LEH3C80T CDB2LEH3C100T

CDB2LEH3D63Y CDB2LEH3D80Y CDB2LEH3D100Y CDB2LEH3D63T CDB2LEH3D80T CDB2LEH3D100T

3P+N 12

100 100 100 300 300 300

63 80 100 63 80 100

CDB2LEH6C63Y CDB2LEH6C80Y CDB2LEH6C100Y CDB2LEH6C63T CDB2LEH6C80T CDB2LEH6C100T

CDB2LEH6D63Y CDB2LEH6D80Y CDB2LEH6D100Y CDB2LEH6D63T CDB2LEH6D80T CDB2LEH6D100T

4P

100 100 100 300 300 300

63 80 100 63 80 100

CDB2LEH4C63Y CDB2LEH4C80Y CDB2LEH4C100Y CDB2LEH4C63T CDB2LEH4C80T CDB2LEH4C100T

CDB2LEH4D63Y CDB2LEH4D80Y CDB2LEH4D100Y CDB2LEH4D63T CDB2LEH4D80T CDB2LEH4D100T

15

Tripping Curve

C

Delixi Electric

D

19


CDB7LSP Standard: IEC 61009 Trip Curve: C and D curves Breaking Capacity: 6000A Sensitivity:30mA

Function

CDB7LSP electronic type residual current operated circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Protection of users against indirect contact Additional protection for users against direct contacts (30mA) Protection of electrical installations against insulation faults (fire hazard, etc)

Description

Technical data Rated current: 6, 10, 16, 20, 25, 32, 40A Rated voltage: 230V AC Breaking capacity: 6kA Sensitivity: 30mA Tripping curve: B curve: the magnetic release operates between 3 and 5 In C curve: the magnetic release operates between 5 and 10 In D curve: the magnetic release operates between 10 and 14 In Tropicalization: treatment 2 Protection degree: 2 Connection Up to 10 mm2 cables Mechanical indication of the earth fault on the front face by a red mechanical indicator 35 mm standard DIN rail mounting

Standard and certification IEC 61009

Type Voltage Sensitivity Rating Width Reference (V) (mA) (A) (mm) B curve 1P+N 230

30

6 10 16 20 25 32 40

18 18 18 18 18 18 18

CDB7LSPN1B6S CDB7LSPN1B10S CDB7LSPN1B16S CDB7LSPN1B20S CDB7LSPN1B25S CDB7LSPN1B32S CDB7LSPN1B40S

C curve

D curve

CDB7LSPN1C6S CDB7LSPN1C10S CDB7LSPN1C16S CDB7LSPN1C20S CDB7LSPN1C25S CDB7LSPN1C32S CDB7LSPN1C40S

CDB7LSPN1D6S CDB7LSPN1D10S CDB7LSPN1D16S CDB7LSPN1D20S CDB7LSPN1D25S CDB7LSPN1D32S CDB7LSPN1D40S

Overall dimensions

20

Delixi Electric


CDL7 Standard:IEC 61008 Sensitivity: 10mA, 30mA, 100mA, 300mA RCCB: Type A , Type AC

Function

CDL7 electromagnetic type residual current switch combine the following functions: Protection for users against indirect contact Additional protection for users against direct contacts (30mA) Protection for electrical installations against insulation faults (fire hazard, etc) Isolation

Description

Technical data Rated current: 25, 40, 63, 80, 100A Rated voltage: 230/400V AC Sensitivity: 10mA, 30mA, 100mA, 300mA Mechanical durability: 2000 Electrical durability: 1000 Tropicalization: treatment 2 Protection degree: 2 Connection Tunnel terminals Up to 16 mm2 cables Type A or type AC RCCB, without overload or short-circuit protection Don’t need any auxiliary supply source. Instantaneous earth fault trip, unadjustable Mechanical indication of the earth fault on the front face by a red mechanical indicator 35 mm standard DIN rail mounting

Standard and certification IEC 61008 KEMA, CB

Overall dimensions Unit:mm

Delixi Electric

21


CDL7 Standard:IEC 61008 Sensitivity: 10mA, 30mA, 100mA, 300mA RCCB: Type A , Type AC

22

Type

Width (in mod.of 9mm)

Rating Sensitivity (A) (mA)

Reference A type

AC type

2P

4

25 25 40 63 80 100 25 40 63 80 100 25 40 63 80 100 63 80 100 63 80 100

10 30 30 30 30 30 100 100 100 100 100 300 300 300 300 300 100 100 100 300 300 300

CDL7225LA CDL7225SA CDL7240SA CDL7263SA CDL7280SA CDL72100SA CDL7225YA CDL7240YA CDL7263YA CDL7280YA CDL72100YA CDL7225TA CDL7240TA CDL7263TA CDL7280TA CDL72100TA CDL7263YAS CDL7280YAS CDL72100YAS CDL7263TAS CDL7280TAS CDL72100TAS

CDL7225LC CDL7225SC CDL7240SC CDL7263SC CDL7280SC CDL72100SC CDL7225YC CDL7240YC CDL7263YC CDL7280YC CDL72100YC CDL7225TC CDL7240TC CDL7263TC CDL7280TC CDL72100TC CDL7263YCS CDL7280YCS CDL72100YCS CDL7263TCS CDL7280TCS CDL72100TCS

4P

8

25 25 40 63 80 100 25 40 63 80 100 25 40 63 80 100 63 80 100 63 80 100

10 30 30 30 30 30 100 100 100 100 100 300 300 300 300 300 100 100 100 300 300 300

CDL7425LA CDL7425SA CDL7440SA CDL7463SA CDL7480SA CDL74100SA CDL7425YA CDL7440YA CDL7463YA CDL7480YA CDL74100YA CDL7425TA CDL7440TA CDL7463TA CDL7480TA CDL74100TA CDL7463YAS CDL7480YAS CDL74100YAS CDL7463TAS CDL7480TAS CDL74100TAS

CDL7425LC CDL7425SC CDL7440SC CDL7463SC CDL7480SC CDL74100SC CDL7425YC CDL7440YC CDL7463YC CDL7480YC CDL74100YC CDL7425TC CDL7440TC CDL7463TC CDL7480TC CDL74100TC CDL7463YCS CDL7480YCS CDL74100YCS CDL7463TCS CDL7480TCS CDL74100TCS

Delixi Electric


CDY1 Surge Protective Devices Standard: IEC61643-1

Function

CDY1 surge protective devices provide: Applicable to household appliances and the like to offer protection When there is an over-voltage caused by either lightning strike or operation in the circuit

Description

Technical data Type Pole Nominal discharge current In(8/20us) kA Maximum discharge current Imax(8/20us) kA Maximum continuous operational voltage Uc V Protection level Up kV Leakage cur rent (75%Uc 1mA) uA Response time ns

CDY1-10 CDY1-20 CDY1-40 CDY1-60

CDY1-80

CDY1-100 CDY1-120

1P+N, 2P 5

1P, 1P+N, 2P, 3P, 3P+N, 4P 10 20 30 40

50

60

10

20

100

120

275 1.3

40

60

80

320

275 385 420 275 385 420 275 385 420 275 385 420 275 385 420 275 385 420

1.3

1.3 1.5 1.8 1.5 1.8 2 2 2.2 2.5 2 2.2 2.2 2.2 2.5 2.5 2.2 2.5 2.5

20 25

Standard and certification IEC61643-1

Overall dimensions

CDY1-10

CDY1-20 40 60

CDY1-80 100 120

Delixi Electric

23


CDY1 Surge Protective Devices Standard: IEC61643-1

Imax

Pole

Refernce

10KA

1P+N

CDY1105

10KA

2P

CDY1102

20KA

1P

CDY1201

20KA

2P

CDY1202

20KA

3P

CDY1203

20KA

4P

CDY1204

20KA

1P+N

CDY1205

20KA

3P+N

CDY1206

40KA

1P

CDY1401

40KA

2P

CDY1402

40KA

3P

CDY1403

40KA

4P

CDY1404

40KA

1P+N

CDY1405

40KA

3P+N

CDY1406

60KA

1P

CDY1601

60KA

2P

CDY1602

60KA

3P

CDY1603

60KA

4P

CDY1604

60KA

1P+N

CDY1605

60KA

3P+N

CDY1606

80KA

1P

CDY1801

80KA

2P

CDY1802

80KA

3P

CDY1803

80KA

4P

CDY1804

80KA

1P+N

CDY1805

80KA

3P+N

CDY1806

100KA

1P

CDY11001

100KA

2P

CDY11002

100KA

3P

CDY11003

100KA

4P

CDY11004

100KA

1P+N

CDY11005

100KA

3P+N

CDY11006

120KA

1P

CDY11201

120KA

2P

CDY11202

120KA

3P

CDY11203

120KA

4P

CDY11204

120KA

1P+N

CDY11205

120KA

3P+N

CDY11206

20KA

Phase modle

CDY120PM

40KA

Phase modle

CDY140PM

60KA

Phase modle

CDY160PM

60KA

N-PE

CDY160NP

80KA

N-PE

CDY180NP

100KA

N-PE

CDY1100NP

120KA

N-PE

CDY1120NP

Note:"

Uc

24

" express Maximum continuous operational voltage (Uc) code

275V 275

320V 320

385V 385

420V 420

Delixi Electric


CDPZ50 Standard: IEC60439-1 IEC60670

Function

CDPZ50 distribution box provides illumination devices, sockets and electrical appliances with functions as follows: Protection against overload Protection against over voltage Protection against leakage

Description

Technical data Rated operational voltage Maximum rated current Rated insulation voltage Rated frequency Degree of protection Instantaneous withstand current

AC 400V or AC 230V 100A 500V 50Hz IP30 6KA

Construction feature Holistic steel-plastic construction Free assembly of components Beautiful design Flame retardant industrial plastic in panel The whole panel can move vertically

Standard and certification IEC60439-1 IEC60670

Type

The amount of unit loop*

Reference

Surface installation

6

CDPZ50M6

8

CDPZ50M8

12

CDPZ50M12

16

CDPZ50M16

20

CDPZ50M20

24

CDPZ50M24

6

CDPZ50R6

8

CDPZ50R8

12

CDPZ50R12

16

CDPZ50R16

20

CDPZ50R20

24

CDPZ50R24

Flush installation

*:18mm for one unit loop

Delixi Electric

25


CDPZ50 Standard: IEC60439-1 IEC60670

Overall dimension Unit:mm

Surface installation Loop number

Flush installation

Surface installation

Flush installation

Thickness

A

B

A

B

C

6

171

220

163

220

90

8

207

220

199

220

90

12

279

220

279

220

90

16

351

220

343

220

90

20

423

220

413

220

90

24*

364

303

383

282

90

*:two rows product

26

Delixi Electric


DDS607 Single-phase Electronic Watt-hour Meter Standard:IEC 620531-21:2003

Function

DDS607 single-phase electronic watt-hour meter provide: Measuring energy in household and commercial single-phase network services

Description

Technical Data Accuracy class: 1.0, 2.0 Reference voltage:220V Current specification:1.5(6)A,3(6)A,2.5(10)A,5(20)A,5(30)A 10(40)A,15(60)A,20(80)A,30(100)A Power: 2W/10VA (voltage circuit), 4VA(Current circuit) Two-way measurement function: Being able to accurately measure, antitwodirections of power and the total electricityconsumption in one direction Extended functions: Optional liquid crystal display, infrared communications and 485 communications Normal work temperature:-10-~+45 Limit working temperature:-25-~+55 Normal work voltage:0.9~1.1 Reference voltage Limit work voltage:0.7~1.2 Reference voltage Relative Humidity: 85% Installation conditions:Meter should be installed in indoor drying, ventilation, fire-resistant, solid walls height of 1.8 m about the use of non-corrosive gases in the nvironment, should be moisture-proof. Lightning request:Thunderstorms in more places should be installed in the installation of lightning equipment

Standard and Certification IEC620531-21:2003 KEMA

Overall dimensions

Single-phase Type A,C Meter

Delixi Electric

Single-phase LCD Meter

27


DDS607 Single-phase Electronic Watt-hour Meter Standard:IEC 620531-21:2003

Ordering informationn Function Description

Current specification

Reference

Type A (Import chip)

1.5(6)A

DDS607N16M4A

Type A (Import chip)

2.5(10)A

DDS607N110M4A

Type A (Import chip)

5(20)A

DDS607N120M4A

Type A (Import chip)

5(30)A

DDS607N130M6A

Type A (Import chip)

10(40)A

DDS607N140M4A

Type A (Import chip)

15(60)A

DDS607N160M4A

Type A (Import chip)

20(80)A

DDS607N180M4A

Type A (Import chip)

30(100)A

DDS607N1100M3A

Type C (Domestic chip)

1.5(6)A

DDS607N26M4A

Type C (Domestic chip)

2.5(10)A

DDS607N210M4C

Type C (Domestic chip)

5(20)A

DDS607N220M4C

Type C (Domestic chip)

5(30)A

DDS607N230M6C

Type C (Domestic chip)

10(40)A

DDS607N240M4C

Type C (Domestic chip)

15(60)A

DDS607N260M4C

Type C (Domestic chip)

20(80)A

DDS607N280M4C

Type C (Domestic chip)

30(100)A

DDS607N2100M3C

LCD without 485 communications

1.5(6)A

DDS607N16M4CD

LCD without 485 communications

2.5(10)A

DDS607N110M4CD

LCD without 485 communications

5(20)A

DDS607N120M4CD

LCD without 485 communications

5(30)A

DDS607N130M6CD

LCD without 485 communications

10(40)A

DDS607N140M4CD

LCD without 485 communications

15(60)A

DDS607N160M4CD

LCD without 485 communications

20(80)A

DDS607N180M4CD

LCD with 485 communications

1.5(6)A

DDS607N16M4CD485

LCD with 485 communications

5(20)A

DDS607N120M4CD485

LCD with 485 communications

10(40)A

DDS607N140M4CD485

LCD with 485 communications

15(60)A

DDS607N160M4CD485

LCD with 485 communications and infrared communications 1.5(6)A

DDS607N116M4CD485I

LCD with 485 communications and infrared communications 2.5(10)A

DDS607N110M4CD485I

LCD with 485 communications and infrared communications 5(20)A

DDS607N120M4CD485I

LCD with 485 communications and infrared communications 5(30)A

DDS607N130M6CD485I

LCD with 485 communications and infrared communications 10(40)A

DDS607N140M4CD485I

LCD with 485 communications and infrared communications 15(60)A

DDS607N160M4CD485I

LCD with 485 communications and infrared communications 20(80)A

DDS607N180M4CD485I

LCD with 485 communications and infrared communications 30(100)A

DDS607N1100M3CD485I

Note: Users need special specifications can be customized

28

Delixi Electric


CDM1 Standard: IEC 60947-2

Function

CDM1 molded case circuit breakers can be used to provide the following functions: To distribute electric power and protect circuits and equipment against overload, undervoltage, and short-circuit faults To protect motors against overload, undervoltage and short-circuit faults (Inm²400A) To infrequently start and control AC motors

Description

Technical data Main technical parameters are shown in the table below Type Frame size rated current A Number of poles Rated frequency Hz Rated current In A

CDM1-63 CDM1-100 CDM1-225 CDM1-400 CDM1-630 CDM1-800 CDM1-1250 63 100 225 400 630 800 1250

Rated insulation voltage Ui V Rated impulse withstand voltage Uimp V Rated operational voltage Ue V Icu kA Type M (400V) Type L Ics kA Type M (400V) Type L Arcing distance mm Durability Cycles/h Electrical Mechanical Power consu- Fixed mpution W Plug-in

690V

3P,4P 50 10 16 20 25 32 40 50 63

2P,3P,4P

3P,4P

3P

16 20 100 125 200 350 400 500 400 500 700 800 25 30 160 180 250 315 630 630 700 1000 32 40 200 225 400 800 1250 50 63 80 100 800V

6000V 8000V

400V

400V / 690V

400V

50 25 30 18 50 120 4000 6000 25 30

50 35 30 26

50 35 30 26

120 3000 7000 40 50

120 1500 6500 60 75

70 50 40 30 100 60 1000 4000 40 110

400V 690V 65 45 42 34

400V 70 50 40 30

85 45 -

60 1000 4000 150 200

20 500 2500 135 190

20 500 2500 240 300

Constructional features Thermamagnetic release offers instantaneous trip against short-circuit and long time delay trip against overcurrent The circuit breaker can be of fixed type or plug-in type For 4-pole circuit breakers: N-pole without overcurrent release, it switches on and off with other poles ( Npole lead-make, lag-break) Various accessories can be attached to the circuit breaker to extend its functions, such as undervoltage release, shunt release, ON/OFF position indication contact, and tripped position indication contact, for detail see the accessories part

Standard and certification IEC 60947-2 KEMA, SEMKO, CB, CE

Delixi Electric

29


CDM1 Standard: IEC 60947-2

Type CDM1-63

In A 3P

4P

CDM1-100

2P

3P

4P

CDM1-225

30

2P

10 16 20 25 32 40 50 63 10 16 20 25 32 40 50 63 16 20 25 32 40 50 63 80 100 16 20 25 32 40 50 63 80 100 16 20 25 32 40 50 63 80 100 100 125 160 180 200 225

Reference Type M CDM163M103 CDM163M163 CDM163M203 CDM163M253 CDM163M323 CDM163M403 CDM163M503 CDM163M633 CDM163M104 CDM163M164 CDM163M204 CDM163M254 CDM163M324 CDM163M404 CDM163M504 CDM163M634 CDM1100M162 CDM1100M202 CDM1100M252 CDM1100M322 CDM1100M402 CDM1100M502 CDM1100M632 CDM1100M802 CDM1100M1002 CDM1100M163 CDM1100M203 CDM1100M253 CDM1100M323 CDM1100M403 CDM1100M503 CDM1100M633 CDM1100M803 CDM1100M1003 CDM1100M164 CDM1100M204 CDM1100M254 CDM1100M324 CDM1100M404 CDM1100M504 CDM1100M634 CDM1100M804 CDM1100M1004 CDM1225M1002 CDM1225M1252 CDM1225M1602 CDM1225M1802 CDM1225M2002 CDM1225M2252

Type L CDM163L103 CDM163L163 CDM163L203 CDM163L253 CDM163L323 CDM163L403 CDM163L503 CDM163L633 -----------------CDM1100L163 CDM1100L203 CDM1100L253 CDM1100L323 CDM1100L403 CDM1100L503 CDM1100L633 CDM1100L803 CDM1100L1003 ----------------

Delixi Electric


CDM1 Standard: IEC 60947-2

Type 3P

4P

CDM1-400

3P

4P

CDM1-630

3P

4P

CDM1-800

3P

4P

CDM1-1250 3P

In A

Reference

100 125 160 180 200 225 100 125 160 180 200 225 200 225 250 315 350 400 200 215 250 315 350 400 400 500 630 400 500 630 400 500 630 700 800 400 500 630 700 800 700 800 1000 1250

Type M CDM1225M1003 CDM1225M1253 CDM1225M1603 CDM1225M1803 CDM1225M2003 CDM1225M2253 CDM1225M1004 CDM1225M1254 CDM1225M1604 CDM1225M1804 CDM1225M2004 CDM1225M2254 CDM1400M2003 CDM1400M2253 CDM1400M2503 CDM1400M3153 CDM1400M3503 CDM1400M4003 CDM1400M2004 CDM1400M2254 CDM1400M2504 CDM1400M3154 CDM1400M3504 CDM1400M4004 CDM1630M4003 CDM1630M5003 CDM1630M6303 CDM1630M4004 CDM1630M5004 CDM1630M6304 CDM1800M4003 CDM1800M5003 CDM1800M6303 CDM1800M7003 CDM1800M8003 CDM1800M4004 CDM1800M5004 CDM1800M6304 CDM1800M7004 CDM1800M8004 CDM11250M7003 CDM11250M8003 CDM11250M10003 CDM11250M12503

Type L CDM1225L1003 CDM1225L1253 CDM1225L1603 CDM1225L1803 CDM1225L2003 CDM1225L2253 ------CDM1400L2003 CDM1400L2253 CDM1400L2503 CDM1400L3153 CDM1400L3503 CDM1400L4003 ------CDM1630L4003 CDM1630L5003 CDM1630L6303 ---CDM1800L4003 CDM1800L5003 CDM1800L6303 CDM1800L7003 CDM1800L8003 ----------

Note: The connection mode for CDM1 is the fixed type front connection.

Delixi Electric

31


CDM1 Standard: IEC 60947-2

Key to overall dimensions Type

Poles Overall dimensions L

Install dimensions

L1

W

H

H1

H2

a

b

CDM1-63L

3

135 21

76

89.5

74

21

25

117

3.5

CDM1-63M

3

135 21

76

99

82

28

25

117

3.5

CDM1-63M

4

135 21

103 99

82

28

25

117

3.5

CDM1-100M

2

150 51

65

103.5

87

24

--

129

4.5

CDM1-100L

3

150 51

92

87

68

25

30

129

4.5

CDM1-100M

3

150 51

92

103.5

87

24

30

129

4.5

CDM1-100M

4

150 51

122 103.5

87

24

30

129

4.5

CDM1-225M

2

165 64

75

104

24.5

--

126

5.5

CDM1-225L

3

165 64

107 108

87

24.5

35

126

5.5

CDM1-225M

3

165 64

107 124.5

104

24

35

126

5.5

CDM1-225M

4

165 64

142 124.5

124.5

d

104

24.5

35

126

5.5

CDM1-400L,M 3

257 105 140 146

100

36.5

44

215

6.5

4

257 105 184 146

100

36.5

44

215

6.5

CDM1-630L,M 3

270 118

182 160

108

41

58

200

7

4

270 118

CDM1-400M CDM1-630M

240 160

108

41

58

200

7

CDM1-800L,M 3

280 102 210 146

103

34.5

70

243

7

CDM1-800M

4

280 102 280 146

103

34.5

70

243

7

CDM1-1250M

3

406 104 210 190

140.5

58.5

70

375

10

Overall dimensions Unit:mm

2P

32

3P

4P

Delixi Electric


CDM1 Standard: IEC 60947-2

Unit:mm

A 117 129 126 215 200 243

B 25 30 35 44 58 70

H 49 54 54 76 83 76

Unit:mm

A 35 35 65 60 48

Delixi Electric

B 11.5 31 15 15 15

H 46 48 61 61 66

33


CDM1 Standard: IEC 60947-2

Accessories The accessories are fixed into the circuit breaker.

MN (Undervoltage Release) Technical data Rated operating voltage Us(V) Drop-out voltage(V) Pick-up voltage(V)

230V, 400V AC (0.35~0.7) Us (0.85~1.1) Us

MX (Shunt Release) Technical data Rated control voltage US(V) Operating voltage(V)

230V, 400V AC (0.7~1.1) US

OF (Auxiliary Contact) Technical data Rated thermal current Ith 3A Rated operating voltage US(V) 1NO+1NC (Change over) 2NO+2NC (Change over)

0.4A (400V AC)

SD (Alarm Switch) Technical data Rated thermal current Ith 3A Rated operating voltage US(V)

0.26A (400V AC) 0.4A (400V AC)

1NO+1NC

34

Delixi Electric


CDM1 Standard: IEC 60947-2

Ordering information Voltage (V) Type 230V AC 400V AC

CDM1-63 CDM1-100 CDM1-225 CDM1-400 CDM1-630 CDM1-800 CDM1-1250

Delixi Electric

Reference MN* CDM163MN230 CDM163MN400 CDM1100MN230 CDM1100MN400 CDM1225MN230 CDM1225MN400 CDM1400MN230 CDM1400MN400 CDM1630MN230 CDM1630MN400 CDM1800MN230 CDM1800MN400 CDM11250MN230 CDM11250MN400

MX* CDM163MX230 CDM163MX400 CDM1100MX230 CDM1100MX400 CDM1225MX230 CDM1225MX400 CDM1400MX230 CDM1400MX400 CDM1630MX230 CDM1630MX400 CDM1800MX230 CDM1800MX400 CDM11250MX230 CDM11250MX400

OF CDM163OF

SD CDM163SD

TR(Round Handle) TS(Square Handle) CDM163TR CDM163TS

CDM1100OF

CDM1100SD

CDM1100TR

CDM1100TS

CDM1225OF

CDM1225SD

CDM1225TR

CDM1225TS

CDM1400OF

CDM1400SD

CDM1400TR

CDM1400TS

CDM1630OF

CDM1630SD

CDM1630TR

CDM1630TS

CDM1800OF

CDM1800SD

CDM1800TR

CDM1800TS

CDM11250OF

35


CDM1L Standard: IEC 60947-2

Function

CDM1L molded case circuit breakers with electronic type residual current operated protection can be used to provide the following functions: To distribute electric power and protect circuits and equipment against overload, undervoltage, and short-circuit faults To infrequently start and control AC motors To protect users against indirect contact To protect electrical installations against insulation faults (fire hazard, etc)

Description

Technical data Main technical parameters are shown in the table below Type

CDM1L-100

CDM1L-225

CDM1L-400

Frame size rated current A

100

225

400

Rated current In A

16 20 25 32 40

100 125 140 160 200 250 315

50 63 80 100

180 200 225

350 400

Rated frequency Hz

50

Rated insulation voltage Ui V

800

Rated operational voltage Ue V

400

Rated impulse withstand voltage Uimp V

8000

Number of poles

3P, 4P

Icu kA

Type M

50

50

70

(400V)

Type L

35

35

50

Ics kA

Type M

35

35

40

(400V)

Type L

22

22

30

Rated residual

Without delay 30/100/500

30/100/500

100/300/500

100/300/500

100/300/500

100/300/500

100/300/500

100/300/500

1/2 I n

1/2 I n

1/2 I n

Electrical

1500

1000

1000

Mechanical

8500

7000

4000

Total

10000

8000

5000

operating current I

n mA

With delay

Rated residual non-operating current I no mA Durability

Maximum break time for residual operating current protection Number of poles

I n

2I n

5I n

10 I n

Max. break

Without delay

0.2

0.1

0.04

0.04

time S

With delay

0.5/1.15/2.15 0.35/1/2

0.25/0.9/1.9 0.25/0.9/1.9

Table for 4 pole CDM1LE (Neutral line) Code Note

36

A

N(direct connect)

B

N(direct connect N pole lead-make, lag-break)

Delixi Electric


CDM1L Standard: IEC 60947-2

Constructional features Thermamagnetic release offers instantaneous trip against short-circuit and long time delay trip against overcurrent The residual operating current value can be fixed or adjustable The residual operating current protection can be with time-delay or without time-delay Various accessories can be attached to the circuit breaker to extend its functions, such as undervoltage release, shunt release, ON/OFF position indication contact, and tripped position indication contact, for detail see the accessories part

Standard and certification IEC 60947-2 CE

Ordering information

Delixi Electric

37


CDM1L Standard: IEC 60947-2

Type CDM1L-100 3P

4P A

4P B

CDM1L-225 3P

4P A

4P B

CDM1-400

38

3P

Rated current Reference In A Type M 16 CDM1LE100M163 20 CDM1LE100M203 25 CDM1LE100M253 32 CDM1LE100M323 40 CDM1LE100M403 50 CDM1LE100M503 63 CDM1LE100M633 80 CDM1LE100M803 100 CDM1LE100M1003 16 CDM1LE100M164 A 20 CDM1LE100M204 A 25 CDM1LE100M254 A 32 CDM1LE100M324 A 40 CDM1LE100M404 A 50 CDM1LE100M504 A CDM1LE100M634 A 63 80 CDM1LE100M804 A CDM1LE100M1004 A 100 16 CDM1LE100M164 B 20 CDM1LE100M204 B CDM1LE100M254 B 25 CDM1LE100M324 B 32 CDM1LE100M404 B 40 CDM1LE100M504 B 50 63 CDM1LE100M634 B 80 CDM1LE100M804 B 100 CDM1LE100M1004 B 100 CDM1LE225M1003 125 CDM1LE225M1253 140 CDM1LE225M1403 160 CDM1LE225M1603 180 CDM1LE225M1803 200 CDM1LE225M2003 225 CDM1LE225M2253 100 CDM1LE225M1004 A 125 CDM1LE225M1254 A 140 CDM1LE225M1404 A 160 CDM1LE225M1604 A 180 CDM1LE225M1804 A 200 CDM1LE225M2004 A 225 CDM1LE225M2254 A 100 CDM1LE225M1004 B 125 CDM1LE225M1254 B 140 CDM1LE225M1404 B 160 CDM1LE225M1604 B 180 CDM1LE225M1804 B 200 CDM1LE225M2004 B 225 CDM1LE225M2254 B 200 CDM1LE400M2003 250 CDM1LE400M2503 315 CDM1LE400M3153 350 CDM1LE400M3503 400 CDM1LE400M4003

Type L CDM1LE100L163 CDM1LE100L203 CDM1LE100L253 CDM1LE100L323 CDM1LE100L403 CDM1LE100L503 CDM1LE100L633 CDM1LE100L803 CDM1LE100L1003 CDM1LE100L164 CDM1LE100L204 CDM1LE100L254 CDM1LE100L324 CDM1LE100L404 CDM1LE100L504 CDM1LE100L634 CDM1LE100L804 CDM1LE100L1004 CDM1LE100L164 CDM1LE100L204 CDM1LE100L254 CDM1LE100L324 CDM1LE100L404 CDM1LE100L504 CDM1LE100L634 CDM1LE100L804 CDM1LE100L1004 CDM1LE225L1003 CDM1LE225L1253 CDM1LE225L1403 CDM1LE225L1603 CDM1LE225L1803 CDM1LE225L2003 CDM1LE225L2253 CDM1LE225L1004 CDM1LE225L1254 CDM1LE225L1404 CDM1LE225L1604 CDM1LE225L1804 CDM1LE225L2004 CDM1LE225L2254 CDM1LE225L1004 CDM1LE225L1254 CDM1LE225L1404 CDM1LE225L1604 CDM1LE225L1804 CDM1LE225L2004 CDM1LE225L2254 CDM1LE400L2003 CDM1LE400L2503 CDM1LE400L3153 CDM1LE400L3503 CDM1LE400L4003

A A A A A A A A A B B B B B B B B B

A A A A A A A B B B B B B B

Delixi Electric


CDM1L Standard: IEC 60947-2

Type

Rated current In A 4P A 200 225 250 315 350 400 CDM1L-400 4P B 200 225 250 315 350 400

Reference Type M CDM1LE400M2004 CDM1LE400M2254 CDM1LE400M2504 CDM1LE400M3154 CDM1LE400M3504 CDM1LE400M4004 CDM1LE400M2004 CDM1LE400M2254 CDM1LE400M2504 CDM1LE400M3154 CDM1LE400M3504 CDM1LE400M4004

A A A A A A B B B B B B

Overall dimensions

Type L CDM1LE400L2004 CDM1LE400L2254 CDM1LE400L2504 CDM1LE400L3154 CDM1LE400L3504 CDM1LE400L4004 CDM1LE400L2004 CDM1LE400L2254 CDM1LE400L2504 CDM1LE400L3154 CDM1LE400L3504 CDM1LE400L4004

A A A A A A B B B B B B

Unit:mm

Key to overall dimensions Type CDM1L-100L

Poles

3 4 CDM1L-100M 3 4 CDM1L-225L 3 4 CDM1L-225M 3 4 CDM1L-400L,M 3 4

Delixi Electric

Overall size L1 L2 92max 150max 122max 150max 92max 150max 122max 150max 107max 165max 142max 165max 107max 165max 142max 165max 154max 257max 198max 257max

L3 94max 94max 110max 110max 94max 94max 110max 110max 146max 146max

L4 75max 75max 92max 92max 72max 72max 90max 90max 103max 103max

Installation size a b d 30 129 4 4.5 60 129 6 4.5 4.5 30 129 4 4.5 60 129 6 4.5 35 126 4 4.5 70 126 6 4.5 35 126 4 4.5 70 126 6 4.5 88 194 4 6.5 88 194 6

39


CDM1L Standard: IEC 60947-2

Handle mechanism Centrally revolvable type Unit:mm

Square Handle

Dimension for handle mechanism Frame

CDM1L-100

CDM1L-225

CDM1L-400

Dimension

49

55

74

Accessories The accessories are fixed into the circuit breaker.

MN (Undervoltage Release) Technical data Rated operating voltage US(V) Drop-out voltage(V) Pick-up voltage(V)

40

230V, 400V AC (0.35~0.7) Us (0.85~1.1) Us

Delixi Electric


CDM1L Standard: IEC 60947-2

MX (Shunt Release) Technical data Rated control voltage Us(V) Operating voltage(V)

230V, 400V AC (0.7~1.1) Us

OF (Auxiliary Contact) Technical data Rated thermal current Ith 3A Rated operating voltage Us(V) 1NO+1NC (Change over) 2NO+2NC (Change over)

0.4A (400V AC)

SD (Alarm Switch) Technical data Rated thermal current Ith 3A Rated operating voltage Us(V)

0.26A (400V AC) 0.4A (400V AC)

1NO+1NC

Ordering information Voltage (V) 230V AC 400V AC

Type CDM1L-100 CDM1L-225 CDM1L-400

Delixi Electric

Reference MN* CDM1LE100MN230 CDM1LE100MN400 CDM1LE225MN230 CDM1LE225MN400 CDM1LE400MN230 CDM1LE400MN400

MX* CDM1LE100MX230 CDM1LE100MX400 CDM1LE225MX230 CDM1LE225MX400 CDM1LE400MX230 CDM1LE400MX400

SD TS(Square Handle) TR(Round Handle) OF CDM1LE100TR CDM1LE100OF CDM1LE100SD CDM1LE100TS CDM1LE225OF CDM1LE225SD CDM1LE225TS

CDM1LE225TR

CDM1LE400OF CDM1LE400SD CDM1LE400TS

CDM1LE400TR

41


CDW7 Standard: IEC 60947-2

Application Applied to power distribution of AC 50Hz, rated operational voltage 400/690V, rated current 200A~6300A and lower For power distribution and protecting circuit and power supply equipment aganist harm from overload, undervoltage, short circuit, earthing, and other faults Circuit breaker which ampere frame size is under 630A can protect motor aganist overload,undervoltage and shortcircuit Core parts use intelligent control unit which has accurate discrimination protection, it can avoid unnecessary power failure and enhance the reliability of power supply system

Standard and certification International standard: IEC609472 Approved certification: CB, CE, KEMA

Operating condition and installation recommendation Ambient temperature shall be controlled between +40 and -5 , the average temperature in 24 hours shall not exceed +35 Note:contacting manufacturer about circuit breaker used in place where ambient temperature is higher than +40 or lower than -5

42

Delixi Electric


CDW7 Standard: IEC 60947-2

Parameter and characteristics Certification approved: IEC 60947-1 IEC 60947-2 CDW7-1000

CDW7-2000

CDW7-3200

CDW7-6300

3, 4

3, 4

3, 4

3, 4

B

B

B

B

0

0

0

0

400

400/690

400/690

400

690

800

800

800

8000

8000

8000

8000

50

50

50

50

200/400/630

630/800/1000

2000/2500

4000/5000

/800/1000

/1250/1600/2000

/3200

/6300

AC 400V

42

80

100

120

AC 690V

--

50

65

--

AC 400V

30

50

80

100

AC 690V

--

40

50

--

AC 400V

88

176

220

264

AC 690V

--

105

143

--

AC 400V

30

50

65

85

AC 690V

--

40

50

--

9000

9000

4500

1500

1000

1000

500

500

In Icu Ics Icm

Delixi Electric

43


CDW7 Standard: IEC 60947-2

Protection characteristics

Fault and alarm reset button “Fault/Alarm” LED In normal state, this LED is off. In case of fault release, the red LED will flash quickly; in case of alarm, the red LED will be on constantly “Normal” LED As long as the controller is on and operates normally, the green LED always flashes Communication indicator The communication state indication is as follows: Profibus: OFF if no communication; ON if communication exists Modbus: OFF if no communication; flash if communication exists Device Net: Flash if no communication; ON if communication exists Curve LEDs Red LEDs exist behind the curve. In case of fault release, the corresponding LED will flash indicating the fault type; During the parameter setting process, the LED is always on and indicates the current item. Keypad Measure key l, used to switch to the default measurement menu. Set key 2, used to switch to the parameter setting menu. Protection Key 3, used to switch to the protection parameter setting menu. Info key 4, used to switch to the historical record and maintenance menu. Up, Move up the cursor through the menu items on the current level, or increment the value of the selected parameter. Down, Move down the cursor through the menu items on the current level, or decrement the value of the selected parameter. Exit, exit from the current level and return to the upper level, or cancel the current parameter selection. Select, Select to enter into the next level from the current item, or select the current parameter, or store the change.

44

Delixi Electric


CDW7 Standard: IEC 60947-2

Delixi Electric

45


CDW7 Standard: IEC 60947-2

46

Delixi Electric


CDW7 Standard: IEC 60947-2

ECW S- H Different curves

Four phase current (I1,

Up to 8 fault logs

LCD display of

MCR and out-of-limit

available for long time

I2, I 3, IN) and earth

Up to 8 alarm logs

Chinese GUI

tripping protection

delay protection

current

Up to 8 position logs

LED indication

DO Signal alarm function

Different curves

Thermal capacity

Historical current peak

Key operation

Communication function

available for inverse

Contact equivalence

short time delay protec-

Number of operating

tion

cycles

Definite short time delay

Clock function

protection

Self-diagnosis function

Instantaneous protection Current unbalance (open phase) protection Earth protection Earth fault alarm Neutral phase protection Load monitor ECW - M

Long time delay protec-

Max. phase current

Fault log

Digital display

DO Signal alarm function

tion

Four phase current (I1,

Self-diagnosis

LED indication

MCR and out-of-limit

Definite time delay +

I2, I 3, IN) and earth

function

Key operation

tripping protection

inverse time delay for

current

Feature test

Digital setting of

Earth fault or leakage

function

protection param-

protection (either)

short time delay protec-

eters

tion Instantaneous protection Earthing protection Load monitor ECW - H

Different curves

Four phase current (I1,

Up to 8 fault logs

LCD display of

Over-voltage protection

available for long time

I2, I 3, IN) and earth

Up to 8 alarm logs

Chinese GUI

Under-voltage protection

delay protection

current

Up to 8 position logs

LED indication

Voltage unbalance

Different curves

Thermal capacity

Historical current

Key operation

protection

available for inverse

peak

Over-currency protection

short time delay protec-

Contact equivalence

Under-frequency

tion

Number of operating

protection

Definite short time delay

cycles

Phase protection

protection

Fault clock function

Inverse power protection

Instantaneous protection

Self-diagnosis fault

Demand protection

MCR and out-of-limit

log

Zonal system interlock

tripping protection

Self-diagnosis

protection

Current unbalance (open

function

Communication function

phase) protection

Feature test

Earth protection

function

Earth fault alarm Neutral phase protection Load monitor

Delixi Electric

47


CDW7 Standard: IEC 60947-2

CDW7-1000

CDW7-2000~6300

ECWS-H intelligent control-

ECW-M intelligent controllers ECW-H intelligent controllers

lers

1.05 1.3 1.5Ir1

Ir h Ir h

Ir=(0.4~1)ln

Ir=(0.4~1)ln

15%

10%

10%

2h

2h

2h

2h

Ir=(0.4~1)ln

1h

8,12.8,19.2,32,48,64,80,

1h 15,30,60,120,240,360,480,

15,30,60,120,240,480

108,144,224,320,480,640,

600,720,840,960

800,960,1120 2.0Ir1

3.32,5.32,8.00,13.32,20.00, 8.4,16.9,33.8,67.5,135,270

8.4,16.9,33.8,67.5,135,202.

26.66,33.30,45.00,60.00,

5,270,337.5,405,472.5,540

93.32,133,200,266,333, 400,433 3.0Ir1

1.25,2.00,3.00,5.00,7.50, 10.0,12.5,16.8,22.5,35.0, 50.0,75.0,100,125,150,162 10% Ir2=(1.5~15)In

Ir2=(1.5~15)In

Ir2=(0.4~15)In

15% Ts=K/10(N2-1),(Ts

15%

15%

10%

10% I2Ts= 8Ir1)2ts

Ts=K/10(N2 -1),(Ts

0.1,0.2,0.3,0.4

0.1,0.2,0.3,0.4

0.1,0.2,0.3,0.4

0.06,0.13,0.2,0.27

0.06,0.16,0.25,0.34

0.06,0.13,0.2,0.27

20ms)

10% CDW7-1000 (1.0~20)ln 15% Ir4=(0.2~1.0)In 10% 0.1s~1s (Rank difference 0.1s)

15%

15%

ECWS-H

ECW-M CDW7-2000

20ms)

ECW-H

CDW7-3200

CDW7-6300

Ir3=1In~50KA+OFF Ir3=1In~75KA+OFF IIr3=1In~100KA+OFF 15% Ir4=(0.2~1.0)In

15%

15%

Ir4=(0.2~1.0)In

10% 0.1~4s (Rank difference 0.1s)

0.1s~1s (Rank difference 0.1s)

15%

48

Delixi Electric


CDW7 Standard: IEC 60947-2

Auxiliary functions

AC 380V

AC220V

(0.35~0.7)Ue

(0.35~0.7)Ue

(0.85~1.1)Ue

(0.85~1.1)Ue 0.35Ue

0.35Ue 36VA

24VA

5VA

5VA

110

70 AC380

AC220

DC220

36VA

24VA

24W

DC110 24W

5VA

5VA

5W

5W

(0.7~1.1)Us less than 30ms

7-2000~6300

AC380

AC220

DC220

DC110

36VA

24VA

24W

24W

10VA

10VA

10W

10W

(0.85~1.1)Us less than 70ms

Delixi Electric

49


CDW7 Standard: IEC 60947-2

AC380

AC220

DC220

CDW7-

In

2000A

85VA

85VA

85VA

85VA

2000~6300 2000A 3200A

In

3200A

110VA

110VA

110VA

110VA

In

6300A

150VA

150VA

150VA

150VA

80VA

80VA

80VA

80VA

CDW7-1000

DC110

(0.85~1.1)Us less than 5s

U/Ue cos

Pe

50

DC-13

10

1

1

1

1

1

0.3

6Pe

I/Ie

10

1.1

U/Ue

1.1

1.1

0.3

6Pe

10

10

cos

0.95

AC-15

T0.

50W T0.95e’s upper limit

300ms

Delixi Electric


CDW7 Standard: IEC 60947-2

Overall and mounting dimension

CDW7-1000A fixed circuit breaker outline and horizonal/vertical connected dimension L L1 200, 400 266 244 630 266 244 800, 1000 266 244 200, 400 336 314 630 336 314 800, 1000 336 314 Delixi Electric

L2 70 70 70

N 6 12 12 8 16 16 51


CDW7 Standard: IEC 60947-2

CDW7-1000A drawout type circuit breaker outline and horizonal/vertical wiring 200, 400 630 800, 1000 200, 400 630 800, 1000 52

3P

4P

L 284 284 284 354 354 354

L1 194 194 194 264 264 264

Unit:mm L2 70 70 70

L3 55 75 75 55 75 75

L4 63 83 83 63 83 83

n 6 12 12 8 16 16

H 6 8 10 6 8 10 Delixi Electric


CDW7 Standard: IEC 60947-2

CDW7-2000A~3200A

CDW7-2000A fixed circuit breaker vertical connection diagram

CDW7-2000A~3200A fixed circuit breaker overall and horizonal/vertical wiring CDW7-2000

CDW7-3200

Unit:mm

L1

L2

L3

L4

In A

3P

362

318

292

340

400~800

4P

457

413

292

435

1000~1600

457

413

292

435

2000

3P

422

378

352

400

2000~2500

4P

537

493

352

515

3200

a 10 15 20 20 30

CDW7-2000 mounting dimension is same regardless of different current used in"horizonal-wiring" or"vertical-wiring"

Delixi Electric

53


CDW7 Standard: IEC 60947-2

CDW7-2000A~6300A

CDW7-2000A drawout circuit breaker vertical connection diagram

CDW7-2000A~6300A drawout type circuit breaker outline and horizonal/vertical connection CDW7-2000

CDW7-3200

CDW7-6300 (4000/5000A) CDW7-6300

3P 4P 3P 4P 4000A 3P 4P 3P

L1 375 375 470 435 550 550 813 928 928

L2 335 335 430 395 510 510 773 888 888

L3 292 292 292 352 352 352 352 352 352

L4 265 265 360 325 440 440 703 818 818

L5 247 247 247 307 307 307 307 307 307

W1 461 461 461 471 471 494 494 494 494

Unit:mm W2 507 507 507 517 517 540 540 540 540

b 179 179 179 189 189 212 212 212 212

In A 400~800 1000~1600 2000 2000~2500 3200~4000 3200~4000 4000 5000~6300 5000~6300

a 10 15 20 20 30 30 20 30 30

W7-3200 can expand to 4000A,which mounting dimension is as same as 4P of CDW7-3200 DW7-2000 the mounting dimension is same regardless of different current used in"horizonal-connected" or "vertical-connected" 54

Delixi Electric


CDW7 Standard: IEC 60947-2

CDW7-1000

CDW7-1000A

CDW7-1000A

CDW7-2000~6300

CDW7-2000~6300A

CDW7-2000~6300A

CDW7-2000~6300 panel cut-out dimension and mounting dimension a

b

Unit:mm c 3P

4P

CDW7-2000

306

346

0

47.5

CDW7-3200

366

406

0

57.5

CDW7-6300

366

406

189(4000/5000A)

246.5(4000/5000A)

246.5(6300A)

--

Delixi Electric

55


CDW7 Standard: IEC 60947-2

Auxiliary connection diagramn

F X with different current ratings shall connect with different sources.

41 42 when controller power choose DC,the output is DC24V,user can select DC power module 43 44 circuit breaker status detection terminal(used when MCR function included) 45 overload pre-alarm signal output 46 automatic diagnosis alarm signal output 47 fault trip alarm signal output 48 earthing but non-tripping,only alarm signal output 49 four groups of contacts output common terminal 50 51 externally sensor input terminal 58 able to directly connect to power supply(automatic pre-energization),also able to join up with normal open pushbutton to connect to power supply(manual preenergization)

56

Delixi Electric


CDW7 Standard: IEC 60947-2

Pin functions: Pin 1# and 2#: Auxiliary power input,pin 1# is positive for DC input Pin 3#, 4#, 5#: Fault trip contact output (4# is common terminal); contact capacity: AC380V, 16A Pin 6# and 7#, 8# and 9#: Two groups of auxiliary contacts for breaker status; contact capacity: AC380V, 16A 12#,13#(Contact1)and 14#,15#(Contact2)and 16#, 17#(Contact3)and 18#,19#(Contact4):Output of four groups of signal for controllers,contact capacity:4A/240V 7A/24VDC 20#: Earth protection 21#~24#:input of voltage signal (Note:the order cant be wrong) Components: Q - Under-voltage release F - Shunt release X – Closing electromagnet DF - Auxiliary switch M - Motor SB1—Button for closing SB2—Button for shunt

Delixi Electric

Note: 1. If the control voltage values of Q, F, X, and M are different to each other, these components can be connected to different power supply units; in the application, the shunt release and closing electromagnet shall be connected serially with normally open and normally closed auxiliary contacts (the part enclosed by dotted lines shall be connected by the user; the part represented by a two-dot chain line is the wiring of circuit 51); Note 2: The pin 35# can be connected to the power supply directly (automatic pre-energy storage) or connected serially to a normally open button and then to the power supply (manual pre-energy storage); Note 3: If the user requests, pin #6~#7 can be connected to normally closed contacts; Note 4: The ECW power supply module I is a DC power supply module, and it can be omitted if the power supply is AC power supply; the polarity and lead-ins/ lead-outs shall not be reversed (for draw-out type circuit breakers, the lead-outs of the power supply module has been connected before the circuit break is shipped from the factory); Note 5: In case of circuit 47, the auxiliary contacts are four closed and four open contacts; pin #25 and #26 are input terminals of an external current transformer , used for earth fault protection as (3P+N)T type ; Note 6: In case of circuit 51, the auxiliary contacts are six closed and six open contacts (or five closed and five open contacts); pin #25, #26, and #51 form normally open and normally closed contacts; Note 7: If Profibus or any other protocol is used, ECW-H + DP conversion module and other conversion modules must be ordered; ECW power supply module lV and ECW201 relay module must be ordered separately; Note 8:Pin #12~#19 input/output contacts can be user-defined programmable signal contacts.

57


CDW7 Standard: IEC 60947-2

1

2: terminal 35# can directly connect to power supply (automatic pre-energy storage),or join up with normal open pushbutton to connect power supply(manual pre-energy storage) 3: terminal 6#~7# can lead out normal close contact if user suggested 4: ECW power supply module is DC power supply module, the module doesn't exist when power supply current is AC, polarity,incoming line and leading-out line shall not connected reversely(leading-out terminal of power supply module in drawout type had been connected before sale) 5: in 47 circuit,auxiliary contact is 4 open 4 close;25# 26# is input terminal of external sensor 6: in 51 circuit,auxiliary contact is 6open6close(5open 5close);25#

26# 51# form normal open normal close

contact(earth-leakage protection excluded) 7: if using profibus or other protocols, user shall order ECW-H+HP transformation module and others;ECW power supply moduleV,ECW201 relay module and others shall order seperately

1# 2#: 1# is the front terminal when DC is supplied by auxiliary power 3# 4# 5 AC380V 16A 6# 7# 8# 9#: two groups of circuit breaker status auxiliary terminal: AC380V 16A 10# 11#: respectively as the communication leading-out of RS485A ,RS485B 12#: overload pre-alarm signal output 13#: communication remote control shunt release output 14#: communication remote control closing output or instantaneous short time-delay trip signal output 15#: communication remote control energy storage or long time-delay trip signal output 16#: S-earth(RS-485 transmissionn common ground wire 17#: load monitor output1 18#: load monitor signal 2 19#: signal output common earth wire 20#: PE line ,shield earth wire 21#: neutral voltage signal N phase 22#: voltage signal A phase 23#: voltage signal B phase 24#: voltage signal C phase

8: #12~#19 output input contacts are programmableselfdefined signal contaccts

58

Delixi Electric


CDW7 Standard: IEC 60947-2

Other additional parameter

Delixi Electric

59


CDW7 Series Air Circuit Breakers

Order Instructions

Customer

Sets purchased

Date

Mode CDW7

Fixed

Draw-out

Rated voltage

AC400

AC690

H Type Intelligent electronic trip

Basic function

3 Poles

4Poles

Rated current

In= A

Overload long delay

Short-circuit short

Short-circuit instantaneous

time protection

delay time protection

protection

Load monitoring function

Metering function

Earthing protection

(Not available for L type)

Power supply

AC 230V

AC 400V

DC 220V

DC 110V

Under-voltage instantaneous trip

AC 230V

Under-voltage time-delay trip

1s

AC 400V

Under-voltage trip 3s

5s

Accessaries

Shunt trip

AC 230V

AC 400V

DC 220V

DC 110V

Energy releasing electromagnet

AC 230V

AC 400V

DC 220V

DC 110V

Motor Driven

AC 230V

AC 400V

DC 220V

DC 110V

Interphase barrier

Escutcheon

N phase external connection

Earth-leakage CT(Only for cable)

Auxiliary switch

standard(4a4b)

special(6a6b)

Auxiliary Connection Terminal Mechanical interlock

1-lock,1-key

2-lock,1-key

3-lock,1-key

Steel-cable interlock

Interlocking rod with 2 switches

Interlocking rod with 3 switches

Door interlock(Available for Draw-out type)

Note:for any special requirement,please contact with the manufacturer.

60

Delixi Electric


CDC17 Standard: IEC 60947-4-1

Function

Description

Technical data Main circuit Rated insulation voltage: 690 V Rated operational voltage: up to 660 V Frequency limits: 50/60 Hz Rated operational current and power of controlled motors are shown in the table below Control circuit Control circuit supply voltage Us: AC 36V, 110V, 127V, 220/230V, 380/400V DC 110V, 220V Technical features Compact, light, low consumption, long-life durability Flame-resistant enclosure ensures a safe & reliable service Full range auxiliaries: - auxiliary contact module - time delay module - mechanical interlock module Direct connection with thermal overload relay to form electomagnetic starter

Standard and certification IEC 60947-4-1 KEMA, CE

Delixi Electric

61


CDC17 Standard: IEC 60947-4-1

Overall dimensions

CDC17-9~32

CDC17-40~95

CDC17-115~150

CDC17-185~330

CDC17-400~500

CDC17-630~1000

Installation dimensions

unit:mm

Type

Amax

Bmax

Cmax

C1max

C2max

a

CDC17-9~12

45

68

77

109

133

35

0.21

59

0.28

4.5

CDC17-18

45

68

82

115

138

CDC17-25

56.5

79

91

124

149

40

0.21

66

0.43

4.5

CDC17-32

56.5

79

95

127

152

CDC17-40~65

75

127

115

145

170

40

0.21

105

CDC17-80~95

85

127

123

153

178

Note:C1max-Contactor+CDF4

b

c

0.57

6.5

C2max-Contactor+CDLA

Type

A

A1

B

C

C1

a1

a2

a3

b1

b2

CDC17-185

138

111

180

163

95

40

20

80

158

154

9

150

7

CDC17-225

138

111

199

163

95

48

25

80

172

172

11

150

7

CDC17-265, 330

171

144

207

201

119

48

25

96

180

180

11

166

11

62

b3

1

Delixi Electric


CDC17 Standard: IEC 60947-4-1

Characteristics Model Rated operational current A

380V / 400V 660V

AC-3 AC-4 AC-3 AC-4

Rated operational voltage V Rated insulation voltage V Rated conventional thermal current A Power of controlled 3-phase cage motor(AC-3) 380V/400V kW 660V AC-3 Electric durabilities(x104 operations) Operating rate(cycles/h) Electric durabilities(x104 operations) Operating rate(cycles/h) Mechanical durabilities(x104 cycles) AC Coil Coil voltage V AC-4

Accessories

Operational voltage V Drop-out voltage V Inrush VA Sealed VA Heat dissipation W Auxiliary contact Time-delay block Mechanical Interlock

Matched Relay Matched Fuse Cross Section of Cable mm2 Weight Kg

Delixi Electric

Number of Piece Flexible cable Inflexible cable

Front mount Side mount Front mount

CDC17-9 CDC17-12 9 12 3.5 5 6.6 8.9 1.5 2 380 / 400 660 690 20 4 5.5 5.5 7.5 100 1200 20 300 1000 36, 48, 110, 220, 380 85%~110%Us 20%~75%Us 70 8 1.8~2.7 CDF4 CDLA2 or CDLA3 CDJL17-1 CDR17-18 RT16-20 1 2 1 2 2.5 4 0.315

CDC17-18 18 7.7 12 3.8

CDC17-25 25 8.5 18 4.4

CDC17-32 32 12 21 7.5

32 7.5 9

40 11 15

50 15 18.5 80

800

110 11 3~4

RT16-32 1 2 4 6 0.335

CDR17-32 RT16-40 1 2

0.513

RT16-50 1 2 6 10 0.510

63


CDC17 Standard: IEC 60947-4-1

Model Rated operational current A

380V / 400V 660V

AC-3 AC-4 AC-3 AC-4

Rated operational voltage V Rated insulation voltage V Rated conventional thermal current A Power of controlled 3-phase cage motor(AC-3) 380V/400V kW 660V AC-3 Electric durabilities(x104 operations) Operating rate(cycles/h) Electric durabilities(x104 operations) Operating rate(cycles/h) Mechanical durabilities(x104 cycles) AC Coil Coil voltage V AC-4

Accessories

Operational voltage V Drop-out voltage V Inrush VA Sealed VA Heat dissipation W Auxiliary contact Time-delay block Mechanical Interlock

Matched Relay Matched Fuse Cross Section of Cable mm2 Weight Kg

64

Number of Piece Flexible cable Inflexible cable

Front mount Side mount Front mount

CDC17-40 CDC17-50 40 50 18.5 24 34 39 9 12 380 / 400 660 690 60 80 18.5 22 30 33 80 1200 20 300 800 36, 48, 110, 220, 380 85%~110%Us 20%~75%Us 200 20 6~10 CDF4 CDLA2 or CDLA3 CDJL17-2 CDR17-95 RT16-63 RT16-80 1 2 1 2 10 16 16 25 1.14

CDC17-65 65 28 42 14

CDC17-80 80 37 49 17.3

30 37

125 37 45 60

CDC17-95 95 44 55 21.3

45

600

RT16-100 1 2 25 25 -

RT16-125 1 2 50 25 50 1.35

RT16-200 1 2 50 25 50 -

Delixi Electric


CDC17 Standard: IEC 60947-4-1

Model Rated operational current A

380V / 400V 660V

AC-3 AC-4 AC-3 AC-4

Rated operational voltage V Rated insulation voltage V Rated conventional thermal current A Power of controlled 3-phase cage motor(AC-3) 380V/400V kW 660V AC-3 Electric durabilities(x104 operations) Operating rate(cycles/h) Electric durabilities(x104 operations) Operating rate(cycles/h) Mechanical durabilities(x104 cycles) AC Coil Coil voltage V AC-4

Accessories

Operational voltage V Drop-out voltage V Inrush VA Sealed VA Heat dissipation W Auxiliary contact Time-delay block Mechanical Interlock

Matched Relay Matched Fuse Cross Section of Cable mm2 Weight Kg

Delixi Electric

Number of Piece Flexible cable Inflexible cable

Front mount Side mount Front mount

CDC17-115 CDC17-150 115 150 52 60 86 110 49 61 380 / 400 660 690 150 55 75 80 100 60 1200 20 300 600 36, 48, 110, 220, 380 85%~110%Us 20%~75%Us 559 33 9.5 CDFC17-11,CDFC17-12 CDJL17-3 CDR17-185 RT16-200 1 2 1 2 95 50 120 20x3 25x3 2.15

CDC17-185 185 79 118 69

CDC17-225 225 85 135 82

CDC17-265 265 105 170 98

CDC17-330 330 117 225 118

210 90 110

225 110 129

300 132 160

300 160 220

300 30 600

1198 83 18.9

695 45 13.5

RT16-250 1 2 150 25x3

JR20-250 RT16-250 1 2 185 32x4

JR20-400 RT16-400 1 2 240 32x4 6.6

1 240 6.6

2 30x5

65


CDC17 Standard: IEC 60947-4-1

Model Rated operational current A

380V / 400V 660V

AC-3 AC-4 AC-3 AC-4

Rated operational voltage V Rated insulation voltage V Rated conventional thermal current A Power of controlled 3-phase cage motor(AC-3) 380V/400V kW 660V AC-3 Electric durabilities(x104 operations) Operating rate(cycles/h) Electric durabilities(x104 operations) Operating rate(cycles/h) Mechanical durabilities(x104 cycles) AC Coil Coil voltage V AC-4

Accessories

Operational voltage V Drop-out voltage V Inrush VA Sealed VA Heat dissipation W Auxiliary contact Time-delay block Mechanical Interlock

Matched Relay Matched Fuse Cross Section of Cable mm2 Weight Kg

66

Number of Piece Flexible cable Inflexible cable

Front mount Side mount Front mount

CDC17-400 CDC17-500 400 500 138 147 305 355 135 145 380 / 400 660 690 500 220 265 280 335 60 300 20 30 600 110, 220, 380 85%~110%Us 20%~75%Us 780 10 8 CDFC17-21 JR20-400 JR20-630 RT16-500 RT16-630 2 150 185 30x5 40x5 9.36

CDC17-630 630 188 460 170

CDC17-800 800 242 530 215

CDC17-1000 1000 580 -

800 335 450

450 500

1000 560 560

600

1050 12 10

RT16-800 240 50x5 22.8

RT17-4/1000

RT17-4/-1250

60x5

80x5

Delixi Electric


CDC17 Standard: IEC 60947-4-1

Ordering information Rate current (A)

Contact blooks NO NC 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

9 12 18 25 32 40 50 65 80 95 115 150 185 225 265 330 400 500 630 800 1000

coil voltage code coil voltage (V)

frequency code frequency

Delixi Electric

36 C

50Hz 5

48 E

Reference CDC17910 CDC17901 CDC171210 CDC171201 CDC171810 CDC171801 CDC172510 CDC172501 CDC173210 CDC173201 CDC174011 CDC175011 CDC176511 CDC178011 CDC179511 CDC1711522 CDC1715022 CDC1718522 CDC1722522 CDC1726522 CDC1733022 CDC1740022 CDC1750022 CDC1763022 CDC1780022 CDC17100022

110 F

220 M

380 Q

60Hz 6

67


CDC17 Standard: IEC 60947-4-1

Description

Application scope

CDF4-20 Top auxiliary contact

CDF420

CDF4-11 Top auxiliary contact

CDF411

CDF4-02 Top auxiliary contact

CDF402

CDF4-22 Top auxiliary contact

CDF422

CDF4-13 Top auxiliary contact

CDC17-9~95A

CDF413

CDF4-31 Top auxiliary contact

CDF431

CDF4-04 Top auxiliary contact

CDF404

CDF4-40 Top auxiliary contact

CDF440

CDLA2 On delay 0.1~3S

CDFC1711

CDLA2 On delay 0.1~30S CDLA2 On delay 10~180S

CDFC1712 CDC17-9~95A

CDFC1721

CDLA3 off delay 0.1~3S

CDLA2ON0

CDLA3 off delay 0.1~30S

CDLA2ON2

CDLA3 off delay 10~180S

68

Reference

CDLA2ON4

CDFC17-11 Side auxiliary contact

CDC17-115~330A

CDLA3OFF0

CDFC17-12 Side auxiliary contact

CDC17-115~330A

CDLA3OFF2

CDFC17-21 Side auxiliary contact

CDC17-400~1000A

CDLA3OFF4

CDJL17-1 Mechanical interlocking module CDC17-9~32A

CDJL171

CDJL17-2 Mechanical interlocking module CDC17-40~95A

CDJL172

CDJL17-3 Mechanical interlocking module CDC17-115~330A

CDJL173

Delixi Electric


CDR17 Standard: IEC 60947-4-1 60947-5-1

Function

CDR17 series thermal overload relays provide: Protection of circuits and motors against overload Protection of circuits and motors against phase loss Motor starters installation in association with contactors

Description

Technical data Main circuit: Frequency limits: 50/60 Hz Rated insulation voltage: 690 V Rated operational voltage: up to 690 V Frame size rated current: 18, 32, 95, 185A Rated operational current and range of current setting are shown in the table below Table 1 Type

Rated insulation voltage Ui V

CDR17-18 690

CDR17-32 690

Delixi Electric

Frame Rated Thermal protection size current No Rated Range of rated Ie A current current current setting A setting A

Reference

18

32

18

32

1801

0.15

0.1~0.13~0.15

CDR1718P15

1802

0.18

0.12~0.16~0.18

CDR1718P18

1803

0.25

0.18~0.2~0.25

CDR1718P25

1804

0.36

0.25~0.32~0.36

CDR1718P36

1805

0.5

0.35~0.4~0.5

CDR1718P5

1806

0.7

0.5~0.6~0.7

CDR1718P7

1807

0.9

0.63~0.72~0.9

CDR1718P9

1808

1.2

0.9~1~1.2

CDR17181P2

1809

1.8

1.2~1.6~1.8

CDR17181P8

1810

2.5

1.8~2~2.5

CDR17182P5

1811

3.6

2.5~3.2~3.6

CDR17183P6

1812

4.8

3.5~4~4.8

CDR17184P8

1813

6.3

4.5~5~6.3

CDR17186P3

1814

7

5~6~7

CDR17187

1815

9

6.3~7.2~9

CDR17189

1816

12

9~10~12

CDR171812

1817

15

11~13~15

CDR171815

1818

18

14~16~18

CDR171818

3201

6.3

4.5~5~6.3

CDR17326P3

3202

7

5~6~7

CDR17327

3203

9

6.3~7.2~9

CDR17329

3204

12

9~10~12

CDR173212

3205

18

12~16~18

CDR173218

3206

25

18~20~25

CDR173225

3207

32

23~25~32

CDR173232

69


CDR17 Standard: IEC 60947-4-1 60947-5-1

Type

Frame Rated Thermal protection current No size Rated Range of Ie A rated current current current setting A setting A

Reference

CDR17-95 690

95

CDR17-185 690

185

95

185

9501

12

9~10~12

CDR179512

9502

18

12~16~18

CDR179518

9503

25

18~20~25

CDR179525

9504

32

23~25~32

CDR179532

9505

40

30~36~40

CDR179540

9506

50

37~45~50

CDR179550

9507

65

48~55~65

CDR179565

9508

70

55~63~70

CDR179570

9508

80

63~70~80

CDR179580

9510

95

75~90~95

CDR179595

8501

50

37~45~50

CDR1718550

8502

65

48~55~65

CDR1718565

8503

70

55~63~70

CDR1718570

8504

80

63~70~80

CDR1718580

8505

95

75~90~95

CDR1718595

8506

115

90~100~115

CDR17185115

8507

135

105~115~135

CDR17185135

8508

150

120~135~150

CDR17185150

8509

160

130~150~160

CDR17185160

8510

185

150~160~185

CDR17185185

Table 2 Basic data for control circuit and auxiliary circuit Rated Conventional Circuit insulation free air thermal type voltage V current A 690

6

Utilization Rated Rated Rated category frequency operational current Hz voltage V A

Control AC-15

50

circuit DC-13 Auxiliary AC-15

50

circuit

Rated control capacity

220(230)

1.64(1.57) 360 VA

380(400)

0.95(0.90)

660(690)

0.55(0.52)

220(230)

0.23(0.22) 50 W

220(230)

6

380(400) 660(690) DC-13

220(230)

Table 3 Limits of operation of relays when energized on all poles Sequence Multiples of Tripping time current setting

Initial condition

Ambient air temperature

1

1.05

Non-trip within 2 hours

From cold

+20 oC

2

1.2

<2h

From hot(immediately

3

1.5

Trip

<2min

following sequence 1

<4min

test)

10A

2s<TP²10s

From cold

10

4s<TP²10s

10A

class 10 4

70

7.2

Delixi Electric


CDR17 Standard: IEC 60947-4-1 60947-5-1

Table 4 Limits of operation when energized on two poles Sequence Multiples of current setting Tripping time Initial condition Any two poles The third-pole

Ambient air temperature

1

1.0

0.9

+20 oC

2

1.15

0

Non-trip

From cold state

within 2 hours <2h

From hot state (immediately following sequence 1 test)

Table 5 Temperature compensation characteristic Sequence

Multiples of Tripping time Initial condition current setting

Ambient air temperature

1

1.0

>2h

From cold state

+55 oC

2

1.2

<2h

From hot state(immediately

3

1.05

>2h

From cold state

4

1.30

<2h

From hot state(immediately

5

0.95

>2h

From cold state

6

1.2

<2h

From hot state(immediately

7

1.05

>2h

From cold state

8

1.35

<2h

From hot state(immediately

following sequence 1 test) -10 oC

following sequence 3 test) +60 oC

following sequence 5 test) -20 oC

following sequence 7 test)

Overall dimensions

CDR17-18

Delixi Electric

71


CDR17 Standard: IEC 60947-4-1 60947-5-1

CDR17-32

CDR17-95

CDR17-185

72

Delixi Electric


LMK Current Transformer Standard: BS7626, IEC44-1

Function

LMK Current Transformer provide: Measuring current

Description

Technical Data Primary current: 100A-5000A Secondary approval: 5A, 1A Maximum voltage: 0.66kV Class: 0.5, 1.0, 3.0 Short time thermal current: Ith=100Ih Rated security coefficient: FS<5

Standard and Certification BS7626, IEC44-1

Overall dimensions

Unit: mm

Delixi Electric

Model

H

W

D

LMK-0.66-20

87

68

42

LMK-0.66-30

79

60

37

LMK-0.66-40

99

75

40

LMK-0.66-50

99

82

40

LMK-0.66-60

126

102

40

LMK-0.66-80

118

125

40

LMK-0.66-100

136

170

40

LMK-0.66-120

136

190

41

73


LMK Current Transformer Standard: BS7626, IEC44-1

Class: 0.5 Maximum Voltage: 0.66KV Model

Current ratio Rated Load Bar (VA) (A) (mm)

30/5 50/5 75/5 100/5 100/5 150/5 200/5 LMK-0.66-30 100/5 200/5 250/5 300/5 LMK-0.66-40 250/5 300/5 400/5 500/5 LMK-0.66-50 300/5 400/5 500/5 600/5 750/5 800/5 1000/5 LMK-0.66-60 500/5 600/5 750/5 800/5 1000/5 1200/5 1500/5 LMK-0.66-80 600/5 750/5 800/5 1000/5 1200/5 1500/5 2000/5 2500/5 LMK-0.66-100 600/5 750/5 800/5 1000/5 1200/5 1500/5 2000/5 2500/5 3000/5 LMK-0.66-120 1500/5 2000/5 2500/5 3000/5 4000/5 5000/5 LMK-0.66-20

74

5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 10-3.75 10-3.75 10-3.75 10-3.75 5-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 15-3.75 15-3.75 20-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 15-3.75 15-3.75 20-3.75 20-3.75 15-3.75 15-3.75 20-3.75 20-3.75 25-3.75 25-3.75

30 30 30 40 40 40 40 50 50 50 50 50 50 50 60 60 60 60 60 60 60 80 80 80 80 80 80 80 80 100 100 100 100 100 100 100 100 100 120 120 120 120 120 120

10 10 10 10 10 10 10 10 10 10 10 10 10 10 20 20 20 20 20 20 20 10 or 60 10 or 60 10 or 60 10 or 60 10 or 60 10 or 60 10 or 60 10 or 60 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80

Diameter Number of Turns Reference through the core (mm)

30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

20 20 20 20 20 20 20 20 20 20 20 30 30 30 30 35 35 35 35 35 35 35 45 45 45 45 45 45 45 50 50 50 50 50 50 50 50 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

5 3 2 2 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

LMKP63020 LMKP65020 LMKP67520 LMKP610020 LMKP610020 LMKP615020 LMKP620020 LMKP610030 LMKP620030 LMKP625030 LMKP630030 LMKP625040 LMKP630040 LMKP640040 LMKP650040 LMKP630050 LMKP640050 LMKP650050 LMKP660050 LMKP675050 LMKP680050 LMKP6100050 LMKP650060 LMKP660060 LMKP675060 LMKP680060 LMKP6100060 LMKP6120060 LMKP6150060 LMKP660080 LMKP675080 LMKP680080 LMKP6100080 LMKP6120080 LMKP6150080 LMKP6200080 LMKP6250080 LMKP6600100 LMKP6750100 LMKP6800100 LMKP61000100 LMKP61200100 LMKP61500100 LMKP62000100 LMKP62500100 LMKP63000100 LMKP61500120 LMKP62000120 LMKP62500120 LMKP63000120 LMKP64000120 LMKP65000120

Delixi Electric


LMK Current Transformer Standard: BS7626, IEC44-1

Class: 1 Maximum Voltage: 0.66KV Model LMK-0.66-20

Current ratio Rated Load Bar (VA) (A) (mm)

30/5 50/5 75/5 100/5 150/5 200/5 LMK-0.66-30 100/5 200/5 250/5 300/5 LMK-0.66-40 250/5 300/5 400/5 500/5 600/5 LMK-0.66-50 300/5 400/5 500/5 600/5 750/5 800/5 1000/5 1200/5 LMK-0.66-60 500/5 600/5 750/5 800/5 1000/5 1200/5 1500/5 2000/5 LMK-0.66-80 600/5 750/5 800/5 1000/5 1200/5 1500/5 2000/5 2500/5 LMK-0.66-100 600/5 750/5 800/5 1000/5 1200/5 1500/5 2000/5 2500/5 3000/5 LMK-0.66-120 1500/5 2000/5 2500/5 3000/5 4000/5 5000/5

Delixi Electric

5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 10-3.75 5-3.75 5-3.75 5-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 5-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 15-3.75 15-3.75 20-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 15-3.75 15-3.75 20-3.75 20-3.75 15-3.75 15-3.75 20-3.75 20-3.75 25-3.75 25-3.75

30 30 30 40 40 40 40 40 50 50 50 50 50 50 50 60 60 60 60 60 60 60 60 60 80 80 80 80 80 80 80 80 100 100 100 100 100 100 100 100 100 120 120 120 120 120 120

10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 20 20 20 20 20 20 20 20 20 10 or 60 10 or 60 10 or 60 10 or 60 10 or 60 10 or 60 10 or 60 10 or 60 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80

Diameter Number of Turns through the core Reference (mm)

30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

20 20 20 20 20 20 20 20 20 20 30 30 30 30 30 35 35 35 35 35 35 35 35 45 45 45 45 45 45 45 45 50 50 50 50 50 50 50 50 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

5 3 2 2 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

LMKP6P13020 LMKP6P15020 LMKP6P17520 LMKP6P110020 LMKP6P115020 LMKP6P120020 LMKP6P110030 LMKP6P120030 LMKP6P125030 LMKP6P130030 LMKP6P125040 LMKP6P130040 LMKP6P140040 LMKP6P150040 LMKP6P160040 LMKP6P130050 LMKP6P140050 LMKP6P150050 LMKP6P160050 LMKP6P175050 LMKP6P180050 LMKP6P1100050 LMKP6P1120050 LMKP6P150060 LMKP6P160060 LMKP6P175060 LMKP6P180060 LMKP6P1100060 LMKP6P1120060 LMKP6P1150060 LMKP6P1200060 LMKP6P160080 LMKP6P175080 LMKP6P180080 LMKP6P1100080 LMKP6P1120080 LMKP6P1150080 LMKP6P1200080 LMKP6P1250080 LMKP6P1600100 LMKP6P1750100 LMKP6P1800100 LMKP6P11000100 LMKP6P11200100 LMKP6P11500100 LMKP6P12000100 LMKP6P12500100 LMKP6P13000100 LMKP6P11500120 LMKP6P12000120 LMKP6P12500120 LMKP6P13000120 LMKP6P14000120 LMKP6P15000120

75


RT16 Fuse Standard: IEC 60269

Function

Description

RT16 fuse provide: Protection of circuits against overload current Protection of circuits against short-circuit current

Technical Data Rate current range:2-630A Rate voltage:500/660V Rate breaking capacity:120KA(500V),50KA(660V)

Standard and certification IEC60269 CE

Overall dimensions

Type

RT16-00

RT16-1

RT16-2

RT16-3

a

78.5

135

150

150

b

29

48

58

67

c

57

62

72

85

d

49

67

67

67

e

6

6

6

6

A

30

58

64

64

B

120

200

250

250

C1

61

83

99

105

C2

85

96

112

120

D

100

175

200

210

E

25

25

25

25

F

7.5

10.5

10.5

10.5

30

30

30

G

76

Delixi Electric


RT16 Fuse Standard: IEC 60269

Ordering information Fuse-link Rate current In(A) Suitable fuse bases RT16-00

2

RT16-00

Weight(g) 170

RT16004

6

RT16006

8

RT16008

10

RT160010

12

RT160012

16

RT160016

20

RT160020

25

RT160025

32

RT160032

40

RT160040

50

RT160050

63

RT160063

80

RT160080

100

RT1600100

125

RT1600125

80

RT1600160 RT16-1

450

RT161100

125

RT161125

160

RT161160

200

RT161200

125

RT161250 RT16-2

660

RT162160

200

RT162200

250

RT162250

300

RT162300

315

RT162315

355

RT162355

315

160

RT162400 RT16-3

850

RT163355

400

RT163400

450

RT163450

500

RT163500

630

RT163630

Material

Weight(g)

Reference

Ceramic

200

RT1600ZT

Resin RT16-1

250

Ceramic

RT1600ZS 700

Resin RT16-2

400

Ceramic

630

Ceramic Resin

Delixi Electric

RT161ZT RT161ZS

1150

Resin RT16-3

RT163315

355

Fuse Base Rate current In(A) RT16-00

RT162125

160

400 RT16-3

RT16180

100

250 RT16-2

RT16002

4

160 RT16-1

Reference

RT162ZT RT162ZS

1280

RT163ZT RT163ZS

77


RT18 Fuse Standard: IEC 60269

Function

RT18 fuse provide: Protection of circuits against overload current Protection of circuits against short-circuit current

Description

Technical Data Rate current range:2-63A Rate voltage:380V Rate breaking capacity:100KA

Standard and certification IEC60269 CE

Overall dimensions

Cylindrical Fuse Type

Size

L

RT18-32

10

38

38

RT18-63

14

51

51 +0.6 -1.0

C 0.6

Hmax

10.3

0.1

10.5

14.3

0.1

13.8

Holder of fuse

78

Type

A

B

C

D

E

F

G

RT18-32

63

60

79

35

80

18

54

RT18-63

78

76

103

35

110

25

75

Delixi Electric


RT18 Fuse Standard: IEC 60269

Cylindrical Fuse

Rate current In(A)

Weight(g)

Reference

RT18-32

2

8

RT10382

4

RT10384

6

RT10386

8

RT10388

10

RT103810

12

RT103812

16

RT103816

20

RT103820

25

RT103825

32

RT103832

2

RT18-63

RT14512

20

4

RT14514

6

RT14516

8

RT14518

10

RT145110

12

RT145112

16

RT145116

20

RT145120

25

RT145125

32

RT145132

40

RT145140

50

RT145150

63

RT145163

Holder of fuse Pole Rate current In(A) Note

Weight(g) Reference

RT18-32X

82

1P

32

Material:Resin Pilotlamp

2P

RT1832Z2XB RT1832Z3XB

3P RT18-32

1P

32

Material:Resin

82

Not Pilotlamp

2P 1P

RT1832Z3B 32

Material:Nylon

82

RT1832Z3X

3P 1P

32

Material:Nylon

82

Not Pilotlamp

2P 1P

RT1832Z3 63

Material:Resin

206

RT1863Z3XB

3P 1P 2P 3P

Delixi Electric

RT1863ZXB RT1863Z2XB

Not Pilotlamp

2P RT18-63

RT1832Z RT1832Z2

3P RT18-63X

RT1832ZX RT1832Z2X

Pilotlamp

2P RT18-32

RT1832ZB RT1832Z2B

3P RT18-32X

RT1832ZXB

63

Material:Resin Pilotlamp

206

RT1863ZB RT1863Z2B RT1863Z3B

79


JXF Power Distribution Box Standard: IEC 670.1989, IEC 60439-1

Function

JXF power distribution box provide: Control,monitoring,measurement and protection for the electric power lines and the main power control equipment

Description

Technical Data Rated operating voltage:220V,380V Rated insulated voltage:400V,660V Rated operating current:400A Protection rating:IP30 for complete set,IP43 for box Instantaneous withstand current:6KA,15KA

Standard and certification IE670.1989,IEC60439-1

Overall dimensions

cover plate

sealing strip

sealing strip

handle lock door peg board

80

box

hinge

Delixi Electric


JXF Power Distribution Box Standard: IEC 670.1989, IEC 60439-1

Delixi Electric

Dimension Istallation dimension D H1 B1

Type

Thickness of iron Figure charge dimension H W

JXF-2520/14

1.0

250 200 140 290 150 170 158 1

JXF252014

JXF-3025/14

1.0

300 250 140 340 200 220 208 1

JXF302514

JXF-3025/18

1.0

300 250 180 340 200 220 208 1

JXF302518

JXF-3030/14

1.0

300 300 140 340 250 220 258 1

JXF303014

JXF-3030/18

1.0

300 300 180 340 250 220 258 1

JXF303018

JXF-4030/14

1.0

400 300 140 440 250 320 258 1

JXF403014

JXF-4030/20

1.0

400 300 200 440 250 320 258 1

JXF403020

JXF-5040/14

1.0

500 400 140 540 350 420 358 1

JXF504014

JXF-5040/20

1.0

500 400 200 540 350 420 358 2

JXF504020

JXF-5040/25

1.0

500 400 250 540 350 420 358 2

JXF504025

JXF-6040/14

1.2

600 400 140 640 350 520 358 2

JXF604014

JXF-6040/20

1.2

600 400 200 640 350 520 358 2

JXF604020

JXF-6040/25

1.2

600 400 250 640 350 520 358 2

JXF604025

JXF-6050/14

1.2

600 500 140 640 450 520 458 2

JXF605014

JXF-6050/20

1.2

600 500 200 640 450 520 458 2

JXF605020

JXF-6050/25

1.2

600 500 250 640 450 520 458 2

JXF605025

JXF-7050/16

1.2

700 500 160 740 450 620 458 2

JXF705016

JXF-7050/20

1.2

700 500 200 740 450 620 458 2

JXF705020

JXF-7050/25

1.2

700 500 250 740 450 620 458 2

JXF705025

JXF-8060/20

1.5

800 600 200 840 550 720 558 2

JXF806020

JXF-8060/25

1.5

800 600 250 840 550 720 558 2

JXF806025

JXF-10080/20 1.5

1000 800 200 1040 750 920 758 2

JXF1008020

JXF-10080/25 1.5

1000 800 250 1040 750 920 758 2

JXF1008025

JXF-10080/30 1.5

1000 800 300 1040 750 920 758 2

JXF1008030

Botoom Number Reference board of lock H6 B6

81


LD11 Series of indicator light Standard: IEC 60947-5-1

Function

LD11 Series of indicator light provide: Pilot signal, anticipating signals Emergency signals and other instructions incidents signal use

Description

Technical data Rated voltage(V) Rated current(mA) Working life(H) Brightness of light(cd/m2) Power frequency withstand voltage Degree of protection

AC/DC 6 12 24 36 48 110 220 50 30000 40 2500V AC 1min IP65

AC 220 380 20

Standard and certification IEC 60947-5-1 CE

82

Delixi Electric


LD11 Series of indicator light Standard: IEC 60947-5-1

Button colour

Rated voltage

Reference

AC.DC 6V

LD1122A21T7

Overall dimensions

Unit:mm

LD1122A21T3 LD1122A21T4 LD1122A21T5 LD1122A21T8 AC.DC 12V

LD1122A21J7 LD1122A21J3 LD1122A21J4 LD1122A21J5 LD1122A21J8

AC.DC 24V

LD1122A21B7 LD1122A21B3 LD1122A21B4 LD1122A21B5 LD1122A21B8

AC.DC 110V

LD1122A21F7 LD1122A21F3 LD1122A21F4 LD1122A21F5 LD1122A21F8

AC.DC 220V

LD1122A21M7 LD1122A21M3 LD1122A21M4 LD1122A21M5 LD1122A21M8

AC 220V

LD1122A41M7 LD1122A41M3 LD1122A41M4 LD1122A41M5 LD1122A41M8

AC 380V

LD1122A41Q7 LD1122A41Q3 LD1122A41Q4 LD1122A41Q5 LD1122A41Q8

AC.DC 6V

LD1122B21T7 LD1122B21T3 LD1122B21T4 LD1122B21T5 LD1122B21T8

AC.DC 12V

LD1122B21J7 LD1122B21J3 LD1122B21J4 LD1122B21J5 LD1122B21J8

AC.DC 24V

LD1122B21B7 LD1122B21B3 LD1122B21B4

Delixi Electric

83


LD11 Series of indicator light Standard: IEC 60947-5-1

Button colour

Rated voltage

Reference

AC.DC 24V

LD1122B21B5

Overall dimensions

Unit:mm

LD1122B21B8 AC.DC 110V

LD1122B21F7 LD1122B21F3 LD1122B21F4 LD1122B21F5 LD1122B21F8

AC.DC 220V

LD1122B21M7 LD1122B21M3 LD1122B21M4 LD1122B21M5 LD1122B21M8

AC 220V

LD1122B41M7 LD1122B41M3 LD1122B41M4 LD1122B41M5 LD1122B41M8

AC 380V

LD1122B41Q7 LD1122B41Q3 LD1122B41Q4 LD1122B41Q5 LD1122B41Q8

AC.DC 6V

LD1122C21T7 LD1122C21T3 LD1122C21T4 LD1122C21T5 LD1122C21T8

AC.DC 12V

LD1122C21J7 LD1122C21J3 LD1122C21J4 LD1122C21J5 LD1122C21J8

AC.DC 24V

LD1122C21B7 LD1122C21B3 LD1122C21B4 LD1122C21B5 LD1122C21B8

AC 220V

LD1122C41M7 LD1122C41M3 LD1122C41M4 LD1122C41M5 LD1122C41M8

AC 380V

LD1122C41Q7 LD1122C41Q3 LD1122C41Q4 LD1122C41Q5 LD1122C41Q8

84

Delixi Electric


LD11 Series of indicator light Standard: IEC 60947-5-1

Button colour

Rated voltage

Reference

AC.DC 6V

LD1122D21T7

Overall dimensions

Unit:mm

LD1122D21T3 LD1122D21T4 LD1122D21T5 LD1122D21T8 AC.DC 12V

LD1122D21J7 LD1122D21J3 LD1122D21J4 LD1122D21J5 LD1122D21J8

AC.DC 24V

LD1122D21B7 LD1122D21B3 LD1122D21B4 LD1122D21B5 LD1122D21B8

AC 220V

LD1122D41M7 LD1122D41M3 LD1122D41M4 LD1122D41M5 LD1122D41M8

AC 380V

LD1122D41Q7 LD1122D41Q3 LD1122D41Q4 LD1122D41Q5 LD1122D41Q8

Delixi Electric

85


LAY3 Serie of pushbuttons Standard: IEC 60947-5-1

Function

LAY3 Serie of Pushbuttons: Control and signal chain

Description

Technical data Conventional thermal current(A) AC-15 Rated operational voltage(V) Rated operational current(A) DC-13 Rated operational voltage(V) Rated operational current(A) Degree of protection Degree of pollution Type of installation Altitude Ambient air temperature

10 660 1.5 440 0.1 IP55 3

380 2.5 220 0.3

220 4.5 110 0.6

2000m -5 ~+40

Standard and certification IEC 60947-5-1

86

Delixi Electric


LAY3 Serie of pushbuttons Standard: IEC 60947-5-1

Flush Button Button colour

Contact blooks

Note

Reference

1NO+1NC

Momentary

LAY311BN4

1NO+1NC

(Non-illuminated)

LAY311BN3

1NO+1NC

LAY311BN2

1NO+1NC

LAY311BN5

1NO+1NC

LAY311BN6

1NO+1NC

LAY311BN1

Overall dimensions

Unit:mm

LAY3 general

Selector Switche-Short Handle 1NO+1NC

Two-position

LAY311X204

1NO+1NC

Maintained

LAY311X203

1NO+1NC

LAY311X202 LAY3-X/2 Selector Swiches

1NO+1NC

Three-position

LAY311X304

1NO+1NC

Maintained

LAY311X303

1NO+1NC

LAY311X302 LAY3-X/3 Selector Swiches

Emergency Stop Pushbutton 1NO+1NC

Maintained

LAY311ZS14

1NO+1NC

LAY311ZS13

1NC

LAY301ZS14

LAY3-ZS/1 Maintained

Flush Buttons Illuminated 1NO+1NC

Incandescent lamp LAY311D4T

1NO+1NC

AC DC 6V

1NO+1NC 1NO+1NC

LAY311D4T LED AC DC 6V

LAY311D4TL

1NO+1NC

LAY311D3TL

1NO+1NC

LAY311D5TL

1NO+1NC

NEON AC 220V

LAY311D3MN

1NO+1NC

LAY311D5MN NEON AC 380V

LAY3-D Illuminated

LAY311D4MN

1NO+1NC

1NO+1NC

Delixi Electric

LAY311D3T

LAY311D4QN

1NO+1NC

LAY311D3QN

1NO+1NC

LAY311D5QN

87


LAY7 Serie of pushbuttons Standard: IEC 60947-5-1

Function

LAY7 Serie of Pushbuttons: Control and signal chain

Description

Technical data Conventional thermal current(A) AC-15 Rated operational voltage(V) Rated operational current(A) DC-13 Rated operational voltage(V) Rated operational current(A) Degree of protection Degree of pollution Type of installation Altitude Ambient air temperature

10 660 1.1 440 0.25 IP55 3

380 2.0 220 0.5

220 3.3 110 1

2000m -5 ~+40

Standard and certification IEC 60947-5-1 CE

Overall dimensions

Unit:mm

Type

22, A

25,

30 B 1-2 block 50

3-4 block 70

66

86

48

68

Flush Button Momentary

14

Extended Button Momentary

20

Whole protection cover button

20

Flush Buttons Illuminated

22

Mushroom Pushbutton Illuminated

24.5

Mushroom Pushbutton Non-illuminated

24.5

Flush Button Maintained

14

Extended Button Maintained

20

Mushroom Pushbutton Maintained

24.5

Flush Button Maintained Illuminated

22

66

86

Emergency Stop Pushbutton

24.5

48

48

Selector Swiches-Short Handle

26

Selector Swiches-Long Handle

26

Key-operated Selector Swiches

40

Note: long 37mm, wide A 30mm B 42mm, in the table values is max.

88

Delixi Electric


LAY7 Serie of pushbuttons Standard: IEC 60947-5-1

Flush Button Button colour

Contact blooks

Note

Reference

1NO+1NC

Momentary

LAY711BN12

1NO+1NC

(Non-illuminated)

LAY711BN22

1NO+1NC

LAY711BN32

1NO+1NC

LAY711BN42

1NO+1NC

LAY711BN52

1NO+1NC

LAY711BN62

1NO+1NC

Maintained

LAY711BNZS12

1NO+1NC

(Non-illuminated)

LAY711BNZS22

1NO+1NC

LAY711BNZS32

1NO+1NC

LAY711BNZS42

1NO+1NC

LAY711BNZS52

1NO+1NC

LAY711BNZS62

Extended Button 1NO+1NC

Momentary

LAY711GN12

1NO+1NC

(Non-illuminated)

LAY711GN22

1NO+1NC

LAY711GN32

1NO+1NC

LAY711GN42

1NO+1NC

LAY711GN52

1NO+1NC

LAY711GN62

1NO+1NC

Maintained

LAY711GNZS12

1NO+1NC

(Non-illuminated)

LAY711GNZS22

1NO+1NC

LAY711GNZS32

1NO+1NC

LAY711GNZS42

1NO+1NC

LAY711GNZS52

1NO+1NC

LAY711GNZS62

1NO+1NC

LAY711JN12

1NO+1NC

LAY711JN22

1NO+1NC

LAY711JN32

1NO+1NC

LAY711JN42

1NO+1NC

LAY711JN52

1NO+1NC

LAY711JN62

Whole protection cover button

Delixi Electric

89


LAY7 Serie of pushbuttons Standard: IEC 60947-5-1

Selector Switche-Short Handle Button colour

Contact blooks

Note

Reference

1NO+1NC

Two-position Maintained

LAY711X2022

1NO+1NC

LAY711X2032

1NO+1NC

LAY711X2042

1NO+1NC

Three-position Maintained

LAY711X3022

1NO+1NC

LAY711X3032

1NO+1NC

LAY711X3042

2NO

LAY720X3022

2NO

LAY720X3032

2NO

LAY720X3042

1NO+1NC

Two-position Right Momentary

LAY711X2122

1NO+1NC

Three-position Right Momentary

LAY711X3122

1NO+1NC

Three-position Right and left Momentary

LAY711X3322

2NO

Three-position Right and left Momentary

LAY720X3322

1NO+1NC

Two-position Maintained

LAY711XB2022

Selector Switche-Long Handle LAY711XB2032

1NO+1NC

LAY711XB2042

1NO+1NC 1NO+1NC

Three-position Maintained

LAY711XB3022

1NO+1NC

LAY711XB3032

1NO+1NC

LAY711XB3042

2NO

LAY720XB3022

2NO

LAY720XB3032 LAY720XB3042

2NO 1NO+1NC

Two-position Right Momentary

LAY711XB2122

1NO+1NC

Three-position Right Momentary

LAY711XB3122

1NO+1NC

Three-position Right and left Momentary

LAY711XB3322

2NO

Three-position Right and left Momentary

LAY720XB3322

1NO+1NC

Two-position Maintained

LAY711Y2002

1NO+1NC

Three-position Maintained

LAY711Y3002

2NO

Three-position Maintained

LAY720Y3002

1NO+1NC

Two-position Right Momentary

LAY711Y2102

1NO+1NC

Three-position Right Momentary

LAY711Y3102

1NO+1NC

Three-position Right and left Momentary

LAY711Y3302

2NO

Three-position Right and left Momentary

LAY720Y3302

1NO+1NC

Momentary(Non-illuminated)

LAY711M32

Key-operated Selector Swiche

Mushroom Pushbutton LAY711M42

1NO+1NC

LAY701M42

1NC 1NO+1NC

Momentary(illuminated LED 6V)

1NO+1NC

LAY711DM4T2L

1NO+1NC 1NO+1NC

90

LAY711DM3T2L LAY711DM5T2L

Maintained(Non-illuminated)

LAY711MZS32

1NO+1NC

LAY711MZS42

1NC

LAY701MZS42 Delixi Electric


LAY7 Serie of pushbuttons Standard: IEC 60947-5-1

Emergency Stop Pushbutton Button colour

Contact blooks

Note

Reference

1NO+1NC

LAY711ZS32

1NO+1NC

LAY711ZS42

1NO

LAY710ZS42

Flush Buttons Illuminated 1NO+1NC

Momentary LED 6V

LAY711D3T2L

1NO+1NC

LAY711D4T2L

1NO+1NC

LAY711D5T2L

1NO+1NC 1NO+1NC

LAY711D8T2L Momentary LED 24V

LAY711D7B2L

1NO+1NC

LAY711D3B2L

1NO+1NC

LAY711D4B2L

1NO+1NC

LAY711D5B2L

1NO+1NC

LAY711D8B2L

1NO+1NC

Momentary LED 220V

LAY711D7M2L

1NO+1NC

LAY711D3M2L

1NO+1NC

LAY711D4M2L

1NO+1NC

LAY711D5M2L

1NO+1NC 1NO+1NC

LAY711D8M2L Momentary NEON 220V

LAY711D1M2N

1NO+1NC

LAY711D3M2N

1NO+1NC

LAY711D4M2N

1NO+1NC

LAY711D5M2N

1NO+1NC 1NO+1NC

LAY711D6M2N Momentary NEON 380V

LAY711D1Q2N

1NO+1NC

LAY711D3Q2N

1NO+1NC

LAY711D4Q2N

1NO+1NC

LAY711D5Q2N

1NO+1NC 1NO+1NC

LAY711D6Q2N Maintained LED 6V

LAY711DZS7T2L

1NO+1NC

LAY711DZS3T2L

1NO+1NC

LAY711DZS4T2L

1NO+1NC

LAY711DZS5T2L

1NO+1NC

LAY711DZS8T2L

1NO+1NC

Delixi Electric

LAY711D7T2L

1NO+1NC

Maintained LED 24V

LAY711DZS7B2L

1NO+1NC

LAY711DZS3B2L

1NO+1NC

LAY711DZS4B2L

1NO+1NC

LAY711DZS5B2L

1NO+1NC

LAY711DZS8B2L

91


LAY7 Serie of pushbuttons Standard: IEC 60947-5-1

Flush Buttons Illuminated Button colour

Contact blooks

Note

Reference

1NO+1NC

Maintained LED 220V

LAY711DZS7M2L

1NO+1NC

LAY711DZS3M2L

1NO+1NC

LAY711DZS4M2L

1NO+1NC

LAY711DZS5M2L

1NO+1NC 1NO+1NC

LAY711DZS8M2L Maintained NEON 220V

LAY711DZS3M2N

1NO+1NC

LAY711DZS4M2N

1NO+1NC

LAY711DZS5M2N

1NO+1NC 1NO+1NC

92

LAY711DZS1M2N

1NO+1NC

LAY711DZS6M2N Maintained NEON 380V

LAY711DZS1Q2N

1NO+1NC

LAY711DZS3Q2N

1NO+1NC

LAY711DZS4Q2N

1NO+1NC

LAY711DZS5Q2N

1NO+1NC

LAY711DZS6Q2N

Delixi Electric


LAY8 Serie of pushbuttons Standard: IEC 60947-5-1

Function

LAY8 Serie of Pushbuttons: Control and signal chain

Description

Technical data Conventional thermal current(A) AC-15 Rated operational voltage(V) Rated operational current(A) DC-13 Rated operational voltage(V) Rated operational current(A) Degree of protection Degree of pollution Type of installation Altitude Ambient air temperature

10 660 1.5 440 0.2 IP55 3

380 2.5 220 0.4

220 4.5 110 0.8

2000m -5 ~+40

Standard and certification IEC 60947-5-1 CE

Delixi Electric

93


LAY8 Serie of pushbuttons Standard: IEC 60947-5-1

Flush Button Button colour

Contact blooks

Note

Reference

1NO+1NC

Momentary

LAY811BN1

1NO+1NC

(Non-illuminated)

LAY811BN2

1NO+1NC

LAY811BN3

1NO+1NC

LAY811BN4

1NO+1NC

LAY811BN5

1NO+1NC

LAY811BN6

1NO+1NC

Maintained

LAY811ZS1

1NO+1NC

(Non-illuminated)

LAY811ZS2

1NO+1NC

LAY811ZS3

1NO+1NC

LAY811ZS4

1NO+1NC

LAY811ZS5

1NO+1NC

LAY811ZS6

1NO+1NC

Waterproof

LAY811S1

1NO+1NC

(Non-illuminated)

LAY811S2

1NO+1NC

LAY811S3

1NO+1NC

LAY811S4

1NO+1NC

LAY811S5

1NO+1NC

LAY811S6

Overall dimensions

Unit:mm

Selector Switche-Short Handle 1NO+1NC

Two-position Maintained

1NO+1NC

LAY811X203

1NO+1NC 1NO+1NC

LAY811X202 LAY811X204

Three-position Maintained

LAY811X302

1NO+1NC

LAY811X303

1NO+1NC

LAY811X304

2NO

LAY820X302

1NO+1NC

Two-position Right Momentary

LAY811X312

1NO+1NC

Three-position Right Momentary

LAY811X212

2NO

Three-position Right and left Momentary

LAY820X312

Two-position Maintained

LAY811XB202

Selector Switche-Long Handle 1NO+1NC 1NO+1NC

LAY811XB203

1NO+1NC 1NO+1NC

LAY811XB204 Three-position Maintained

LAY811XB303

1NO+1NC

LAY811XB304

2NO

94

LAY811XB302

1NO+1NC

LAY820XB302

1NO+1NC

Momentary(Non-illuminated)

LAY811XB212

1NO+1NC

Three-position Right Momentary

LAY811XB312

2NO

Three-position Right and left Momentary

LAY820XB332

Delixi Electric


LAY8 Serie of pushbuttons Standard: IEC 60947-5-1

Mushroom Pushbutton Button colour

Contact blooks

Note

Reference

1NO+1NC

LAY811M3

1NO+1NC

LAY811M4

Overall dimensions

Unit:mm

Emergency Stop Pushbutton 1NO+1NC

LAY811ZS3

1NO+1NC

LAY811ZS4

1NO

LAY810ZS4

Flush Buttons Illuminated 1NO+1NC

LED AC.DC 6V

LAY811D3T2L

1NO+1NC

LAY811D4T2L

1NO+1NC

LAY811D5T2L

1NO+1NC 1NO+1NC

LAY811D8T2L LED AC.DC 24V

LAY811D7B2L

1NO+1NC

LAY811D3B2L

1NO+1NC

LAY811D4B2L

1NO+1NC

LAY811D5B2L

1NO+1NC 1NO+1NC

LAY811D8B2L LED AC.DC 220V

LAY811D7M2L

1NO+1NC

LAY811D3M2L

1NO+1NC

LAY811D4M2L

1NO+1NC

LAY811D5M2L

1NO+1NC

LAY811D8M2L

1NO+1NC

LED AC 220V

LAY811D7M4L

1NO+1NC

LAY811D3M4L

1NO+1NC

LAY811D4M4L

1NO+1NC

LAY811D5M4L

1NO+1NC 1NO+1NC

Delixi Electric

LAY811D7T2L

1NO+1NC

LAY811D8M4L LED AC 380V

LAY811D7Q4L

1NO+1NC

LAY811D3Q4L

1NO+1NC

LAY811D4Q4L

1NO+1NC

LAY811D5Q4L

1NO+1NC

LAY811D8Q4L

95


72 Series Pannel Meter Standard: IEC 51-1~9

Function

72 series pannel meter provide: Measuring current,voltage Measuring frequency,power,power factor

Description Pressure test Voltage:2000V Frequency:50Hz Duration:1min

Tolerance mechanical impact:max 147m/s2 Response time: 4s Pointer deflection angle:90

Standard and certification IEC 51-1~9 CE

Overall dimensions Unit:mm

96

Delixi Electric


72 Series Pannel Meter Standard: IEC 51-1~9

Ordering information Type

Accuracy Specification rating

Note

Shape(mm)

Ammeter

1.5

30/5A

AC Type

72

72

67.5

72TA30

40/5A

External connection 72

72

67.5

72TA40

50/5A

transformer

72

72

67.5

72TA50

60/5A

2 times of current

72

72

67.5

72TA60

75/5A

overload

72

72

67.5

72TA75

80/5A

72

72

67.5

72TA80

100/5A

72

72

67.5

72TA100

150/5A

72

72

67.5

72TA150

160/5A

72

72

67.5

72TA160

200/5A

72

72

67.5

72TA200

250/5A

72

72

67.5

72TA250

300/5A

72

72

67.5

72TA300

400/5A

72

72

67.5

72TA400

600/5A

72

72

67.5

72TA600

800/5A

72

72

67.5

72TA800

1000/5A

72

72

67.5

72TA1000

1600/5A

72

72

67.5

72TA1600

5000/5A

72

72

67.5

72TA5000

10000/5A

72

72

67.5

72TA10000

72

72

67.5

72TA5A

5A

AC Type

Reference

Direct connection 2.5

15A

AC Type

72

72

67.5

72TA15A

20A

Direct connection

72

72

67.5

72TA20A

25A

2 times of current

72

72

67.5

72TA25A

30A

overload

72

72

67.5

72TA30A

40A

72

72

67.5

72TA40A

50A

72

72

67.5

72TA50A

60A

72

72

67.5

72TA60A

80A

72

72

67.5

72TA80A

72

72

67.5

72TA100A

1.5

5A

DC Type

72

72

67.5

72C1A5A

1.5

300V

AC Type

72

72

67.5

72TV300

72

72

67.5

72TV500

100A Voltmerer

500V

72

72

67.5

72TV600

500V

DC Type

72

72

67.5

72C1V500

45-55HZ (200V)

AC Type

72

72

67.5

72TZ200

600V Frequency meter

1.0

9

Delixi Electric

97


96 Series Pannel Meter Standard: IEC 51-1~9

Function

96 series pannel meter provide: Measuring current,voltage Measuring frequency,power,power factor

Description Pressure test Voltage:2000V Frequency:50Hz Duration:1min

Tolerance mechanical impact:max 147m/s2 Response time: 4s Pointer deflection angle:90

Standard and certification IEC 51-1~9 CE

Overall dimensions Unit:mm

98

Delixi Electric


96 Series Pannel Meter Standard: IEC 51-1~9

Ordering information Type

Accuracy Specification rating

Note

Shape(mm)

Ammeter

1.5

30/5A

AC Type

96

96

67.5 96TA30

40/5A

External connection 96 transformer 96

96

67.5 96TA40

50/5A

96

67.5 96TA50

60/5A

96

96

67.5 96TA60

75/5A

96

96

67.5 96TA75

80/5A

96

96

67.5 96TA80

100/5A

96

96

67.5 96TA100

150/5A

96

96

67.5 96TA150

160/5A

96

96

67.5 96TA160

200/5A

96

96

67.5 96TA200

250/5A

96

96

67.5 96TA250

300/5A

96

96

67.5 96TA300

400/5A

96

96

67.5 96TA400

600/5A

96

96

67.5 96TA600

800/5A

96

96

67.5 96TA800

1000/5A

96

96

67.5 96TA1000

1600/5A

96

96

67.5 96TA1600

5000/5A

96

96

67.5 96TA5000

10000/5A

96

96

67.5 96TA10000

96

96

67.5 96TA5A

5A

AC Type

Reference

Direct connection 2.5

15A

AC Type

96

96

67.5 96TA15A

20A

Direct connection

96

96

67.5 96TA20A

25A

96

96

67.5 96TA25A

30A

96

96

67.5 96TA30A

40A

96

96

67.5 96TA40A

50A

96

96

67.5 96TA50A

60A

96

96

67.5 96TA60A

80A

96

96

67.5 96TA80A

96

96

67.5 96TA100A

1.5

5A

DC Type

96

96

67.5 96C1A5A

1.5

300V

AC Type

96

96

67.5 96TV300

96

96

67.5 96TV500

100A Voltmerer

500V

96

96

67.5 96TV600

500V

DC Type

96

96

67.5 96C1V500

45-55HZ (200V)

AC Type

96

96

67.5 96TZ200

600V Frequency meter

Delixi Electric

1.0

99


TND Voltage Stabilizer

Function

TND voltage stabilizer provide: Control system consist of linear integrated circuit automaticly control voltage regulation Timelag, overvoltage and undervoltage protection

Description

Technical Data Type

TND0.5kVA~5kVA Voltage regulation accuracy

Output voltage Undervoltage protection Overvoltage protection

220

4%,110

4%

TND7kVA~30kVA 220

4%

184V 4V(set up according to the customers request) 246V

4V

Phase

single-phase

Input voltage range

160V~240V

Efficiency

>90%

Voltage regulation speed

<1s(when input voltage change 10%)

Temperature rise

<60

Frequency

50Hz/60Hz

Enviroment temperature,relative temperature Waveform distortion

-50

(full range) ~40

below 90%

Rated maximum output current(A)

no additional distortion 2(500VA),4(1000VA),6(1500VA),8(2000VA),12(3000VA), 20(5000VA),25(7000VA),40(10KVA),85(15KVA), 73(20KVA),109(30KVA)

Withstand voltage

1500V/1min

Overall dimensions

unit: mm

Product shape

Model

Wide

Length

Desktop

TND-0.5

190

160

135

TND-1

205

190

155

TND-1.5

205

190

155

TND-2

240

270

200

TND-3

225

305

235

TND-5

225

310

290

TND-7

240

387

360

TND-10

240

387

360

TND-10

310

340

535

TND-15

340

360

640

TND-20

340

380

780

TND30

425

390

845

Cabinet type

100

Hight

Delixi Electric


TND Voltage Stabilizer

Ordering information Product shape Desktop

Cabinet type

Delixi Electric

Power rating

Referencce

0.5K

TNDP5

1K

TND1

1.5K

TND1P5

2K

TND2

3K

TND3

5K

TND5

7K

TND7

10K

TND10

10K

TND10G

15K

TND15G

20K

TND20G

30K

TND30G

101


Nylon Cable Ties Series

Description

Technical Data Material:

Color:

Using nylon 66 material that recognized by UL Fire-protection rating:94V-2 Acid and erosion control,insulate well and difficult to aging White, black and other colors

Overall dimensions Long INCH

102

MM

MAX.Bundle Tensile Strength Packing Width DIA(mm) (root) LBS KGS

Reference

2.4"

60

2.5

2-11

18

8

100

DAR205060**

3.2"

80

2.5

2-16

18

8

100

DAR205080**

4"

100

2.5

2-22

18

8

100

DAR205100**

4.7"

120

2.5

2-30

18

8

100

DAR205120**

6" 12"

150 200

2.5 2.5

2-35 3-80

18 18

8 8

100 100

DAR205150** DAR205200**

4.7"

120

3.6

2-30

40

18

100

DAR306120**

6"

150

3.6

2-35

40

18

100

DAR306150**

7.1"

180

3.6

3-42

40

18

100

DAR306180**

8"

200

3.6

3-50

40

18

100

DAR306200**

10" 12"

250 300

3.6 3.6

3-65 3-80

40 40

18 18

100 100

DAR306250** DAR306300**

14.6"

370

3.6

3-80

40

18

100

DAR306370**

7.1"

180

4.8

3-42

50

22

100

DAR408180**

8"

200

4.8

3-50

50

22

100

DAR408200**

10"

250

4.8

3-65

50

22

100

DAR408250**

12" 14"

300 350

4.8 4.8

3-80 3-90

50 50

22 22

100 100

DAR408300** DAR408350**

15"

380

4.8

3-102

50

22

100

DAR408380**

16"

400

4.8

3-105

50

22

100

DAR408400**

17.7"

450

4.8

3-130

50

22

100

DAR408450**

19.7"

500

4.8

3-150

50

22

100

DAR408500**

8" 10"

200 250

7.2 7.2

3-50 3-65

120 120

55 55

100 100

DAR702200** DAR702250**

12"

300

7.2

4-80

120

55

100

DAR702300**

14"

350

7.2

4-90

120

55

100

DAR702350**

16"

400

7.2

4-105

120

55

100

DAR702400**

20"

500

7.2

4-150

120

55

100

DAR702500**

30" 18"

750 450

7.2 9

10-220 8-118

120 175

55 80

100 100

DAR702750** DAR900450**

20"

500

9

8-150

175

80

100

DAR900500**

21.6"

550

9

8-160

175

80

100

DAR900550**

27.5"

700

9

10-205

175

80

100

DAR900700**

32"

800

9

10-230

175

80

100

DAR900800**

2.4" 3.2"

60 80

2.2 2.2

2-11 2-16

18 18

8 8

100 100

DAR202060** DAR202080**

4"

100

2.2

2-22

18

8

100

DAR202100**

4.7"

120

2.2

2-30

18

8

100

DAR202120**

6"

150

2.2

2-35

18

8

100

DAR202150**

8"

200

2.2

3-50

18

8

100

DAR202200**

4.7" 6"

120 150

3.2 3.2

3-30 3-35

40 40

18 18

100 100

DAR302120** DAR302150**

Delixi Electric


Nylon Cable Ties Series

Long INCH

Normal Packing

Hang tag Packing

Delixi Electric

MM

Width

MAX.Bundle Tensile Strength Packing Reference (root) DIA(mm) LBS KGS

7"

180

3.2

3-42

40

18

100

DAR302180

8"

200

3.2

3-50

40

18

100

DAR302200

10"

250

3.2

3-65

40

18

100

DAR302250

12"

300

3.2

3-80

40

18

100

DAR302300

14"

350

3.2

3-90

40

18

100

DAR302350

4.7"

120

4.2

3-30

50

22

100

DAR402120

6"

150

4.2

3-35

50

22

100

DAR402150

7.1"

180

4.2

3-42

50

22

100

DAR402180

8"

200

4.2

3-50

50

22

100

DAR402200

10"

250

4.2

3-65

50

22

100

DAR402250

12"

300

4.2

3-80

50

22

100

DAR402300

14"

350

4.2

3-90

50

22

100

DAR402350

16"

400

4.2

3-105

50

22

100

DAR402400

8"

200

6.5

3-50

120

55

100

DAR605200

10"

250

6.5

3-65

120

55

100

DAR605250

12"

300

6.5

4-80

120

55

100

DAR605300

14"

350

6.5

4-90

120

55

100

DAR605350

16"

400

6.5

4-105

120

55

100

DAR605400

17.7"

450

6.5

3-130

120

55

100

DAR605450

19.7"

500

6.5

4-150

120

55

100

DAR605500

21.6"

550

6.5

4-165

120

55

100

DAR605550

24"

600

6.5

4-170

120

55

100

DAR605600

Note:"

" express color and packing code

Color

Black

White

Blue

Red

Yellow

Green

Normal Packing

BB

WB

UB

RB

YB

GB

Hang tag Packing

BL

WL

UL

RL

YL

GL

103


Power Distribution and Industry Control Product

CDW7

CDM1

JXF CDC17

CDM1

CDM1L

CDPZ50

CDB6a

Building

CDR17

CDY1

LAY3

DDS607

CDB6LE

Industry

LMK

Energy

Residential

72


DELIXI ELECTRIC LTD. ADD: DELIXI LIUSHI INDUSTRIAL PARK, YUEQING, ZHEJIANG, P.R.CHINA POST CODE: 325604 Http: //www.delixi-electric.com


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.