http://www.iqair.com/pdf/Intertek-Studies-P16-2225-2530-AirCleaners

Page 6

Report No. 3098477-001a

July 31, 2006

Page 2 of 4

Airflow Rate in % of Test Airflow Rate 50%

75%

100%

125%

80 0.300 0.250

60 50

0.200

40

0.150

30 0.100 20 0.050

10

0.000

0

1000

Resistance, in. Water

Resistance, Pa

70

1500

Airflow Rate, cfm

2000

2500

Graph 1: Resistance of Clean Device vs. Airflow

Air Velocity Airflow Rate in % of Test m/s Airflow Rate 1.25 50% 1.87 75% 2.50 100% 3.12 125% Table 1: Resistance of Clean Device vs. Airflow

fpm 246.0 369.0 492.0 615.0

Airflow Rate m3/s 0.47 0.71 0.94 1.18

cfm 1000 1500 2000 2500

Resistance Pa 18 33 54 78

in H2O 0.073 0.134 0.215 0.313