Compact inv 10a, buffer, dhw, 1 x heating cooling circuit with p1

Page 1

Legend:

Graphic symbol

CAD/CAE Center Format: A3

HP Flow Shut-off valve

Temperature regulating valve (30-60°C

HC Flow

Shut_off valve with check valve

Three-way diverting valve

Heat consumer

HC Return

Shut-off valve with drainage Three-way mixing valve

Flexible pipe

HP Return

Heat consumer 4 way diverting valve

M

Domestic hot water

Magnetic filter

Check valve

Domestic water

Shut-off valve with drainage

Refrigerant tube R410A Refrigerant tube R410A

Presure regulator Flow switch

T

Filter

Temperature sensor Runoff to the sewer system

Overflow valve

T TR

RP1 - Expansion vesel heating system RP2 - Expansion vesel DHW

Manometer

Air vent

Filter

El. cable

Room sensor

2X0,75mm ²

Thermometer

Safety valve combination

MV1/MV2 -Proportional mixing drive 24V/0-10V controled SELTRON PROMIX AVC10Y ESBE ARA 639

HC/CC 1

El. box Power supply Compact Inverter 10A 3X2,5mm Power supply el. heater 5X2,5mm

² 230V/50Hz

1p/20A/C

² 400V/50Hz

3 x 1p/10A/C

Main power supply 400V/ 50 Hz ,N,PE

AB

MV

3X0,75mm ²

This drawing is the property of GORENJE d.d., and must not, without our consent be copied, handed to other persons or otherwise misused!

DN25

B

AB

3X1,5mm ²

A

Flow switch 2X0,75mm ² Sensors UTP

P1

Power supply to Outdoor unit 3X2,5mm ²

Cominication with shield AVG Cable included

230V / 2kW 400V / 6kW

P0 T

TW

DN25

min 1,5mm ²

gorenje Tuo

Tui

FS

T

RP2

TC

RP1 Tup

0,3m

DN25

1140mm

DN25 0,15m

Opis spremembe/Description of Change Status zaupnosti/Degree of Confidentiality: Izdelal/Designed by: Pregledal/Reviewed by: Tehnolog 1/Technologist 1:

Rev.

Side view DN25

Spremenil/Changed by:

Pre-insulated pipe

Min 1,5m

Rp 1"

Rp 1"

0,3m

Risba je last GORENJA d.d. Vsaka zloraba te risbe, razmnozevanje, prodaja tretji osebi ali uporaba v drugačne namene kot je bilo dogovorjeno, je prepovedana!

Pre-insulated pipe

DN25

DN25

Odobril/Approved by:

Tehnolog 2/Technologist 2:

Nalog/ECO

Standardizer:

Material:

Povrsinska zascita/Surface Treatment:

Standard:

Standard:

Masa/Weight (kg):

Tehnicni predpis/Technical Rules:

Tolerance prostih mer/General Tolerances:

Datum izdaje/Date of Issue:

Klasifikacija risbe/Classification of the Drawing:

Merilo/Scale:

Dimenzije/Dimensions:

List/listov/Sheet/Sheets: Namesto/Replaces:

Naziv: Aerogor Compact Inverter 10A, buffer, DHW, 1 x heating cooling circuit with

Oznaka risbe/Drawing ID:

P1 343mm

Datum/Date

Tehnolog KK/Tehnologist QA: Ident stev./Item ID:

Title:

Revizija/Revision: