Industrial Catalog

Page 53

SPEC 4400

January, 2008

Arctic-Flex

®

XLPE/ARCTIC-PVC, Control, Unshielded 600V, UL Type TC-ER1, CSA Type RW90 XLPE, CSA TYPE TC Product Construction Conductor:

• 14 AWG thru 10 AWG tinned, annealed copper per ASTM B3 • Class B stranding per ASTM B8

Insulation:

CATALOG NUMBER

COPPER MINIMUM AVG. MINIMUM AVG. WEIGHT NET WEIGHT INSULATION JACKET NOMINAL NO. COND. THICKNESS CABLE O.D. LBS/ OF SIZE COND. THICKNESS LBS/ COND. (AWG) STRAND inCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

14 AWG MULTI CONDUCTORS 347340* 347350* 347360* 347370* 347380* 347390* 347400* 347410* 347420* 347430* 347440*

2 3 4 5 7 9 12 19 25 30 37

14 14 14 14 14 14 14 14 14 14 14

7/.0242 7/.0242 7/.0242 7/.0242 7/.0242 7/.0242 7/.0242 7/.0242 7/.0242 7/.0242 7/.0242

347450* 347460* 347470* 347480* 347490* 347500* 347510* 347520* 347530* 347540* 347550*

2 3 4 5 7 9 12 19 25 30 37

12 12 12 12 12 12 12 12 12 12 12

7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305

0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030

0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76

0.045 0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.060 0.080 0.080

1.14 1.14 1.14 1.14 1.14 1.52 1.52 1.52 1.52 2.03 2.03

0.405 0.390 0.425 0.465 0.590 0.620 0.680 0.800 0.985 1.050 1.130

10.29 9.91 10.80 11.81 14.99 15.75 17.27 20.32 25.02 26.67 28.70

25 40 53 66 93 119 159 252 323 387 490

37 59 79 99 138 177 237 375 481 576 729

71 90 113 140 176 245 302 460 641 740 888

106 134 168 208 262 365 449 685 954 1101 1322

41 65 86 108 150 193 258 403 515 618 741

61 96 143 96 125 186 128 157 234 160 191 284 224 260 387 288 340 506 385 429 638 600 681 1013 767 885 1317 920 1005 1496 1103 1185 1764

67 101 135 167 234 295 402

100 150 200 249 349 440 598

12 AWG MULTI CONDUCTORS 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030

0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76

0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.080 0.080 0.080 0.080

1.14 1.14 1.14 1.14 1.52 1.52 1.52 2.03 2.03 2.03 2.03

0.410 0.435 0.475 0.520 0.595 0.695 0.780 0.930 1.095 1.150 1.240

10.41 11.05 12.07 13.21 15.11 17.65 19.81 23.62 27.81 29.21 31.50

10 AWG MULTI CONDUCTORS 347560* 347570* 347580* 347590* 347600* 347610* 347620*

2 3 4 5 7 9 12

10 10 10 10 10 10 10

7/.0385 7/.0385 7/.0385 7/.0385 7/.0385 7/.0385 7/.0385

0.030 0.030 0.030 0.030 0.030 0.030 0.030

0.76 0.76 0.76 0.76 0.76 0.76 0.76

0.045 0.045 0.060 0.060 0.060 0.060 0.080

1.14 1.14 1.52 1.52 1.52 1.52 2.03

0.455 0.485 0.515 0.615 0.670 0.785 0.895

11.56 12.32 13.08 15.62 17.02 19.94 22.73

Dimensions and weights are nominal; subject to industry tolerances. *Non-stock item, minimum runs apply. Please consult Customer Service for price and delivery. 1Approved as TYPE TC-ER for Exposed Run applications of 3 or more conductors as defined by NEC.

130 168 229 281 377 479 644

193 250 341 418 561 713 958

• Flame-retardant Cross-Linked Polyethylene (XLPE) Color-coded per CSA Standard C22.2 No. 38 as follows: Number of color coding of circuit conductors No. of Cond. Color Code 2 blk, wht 3 blk, red, blu 4 blk, red, blu, wht ≥5 all black All conductors for all constructions are alphanumeric printed

Jacket:

• Flame-retardant and sunlight-resistant Arcticgrade Polyvinyl Chloride (PVC)

Print:

• GENERAL CABLE® (WC) (UL) TYPE TC-ER1 ARCTIC-FLEX® XX/C XXAWG FR-XLP/PVC XHHW-2 CDRS 90C WET OR DRY SUN RES DIR BUR 600V - (CSA) TYPE RW90 XLPE -40C TC FT-4 600V PLUS DAY/MONTH/YEAR OF MFG SEQUENTIAL FOOTAGE MARK

Options:

• Bare copper, class C stranding • Uninsulated ground (bonding) conductor • Optional color code as specified per CSA standard C22.2 No. 38 for two to four conductor cable • Non-UL 1000 volt CSA Type RW90 XLPE, CSA Type TC • Other constructions available upon request

Applications:

• Industrial lighting, control and signaling circuits • Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC for UL Type TC cables. In Canada, protection may be required by inspection authority per Canadian electrical code • Permitted for Exposed Run ‘ER’ use in accordance with NEC for 3 or more conductors • Approved for cable in tray, industrial hazardous locations, Class I, Zone 2, and Class II, Division 2 per CEC rules 18-156 and 18-252 when used with certified HL glands

Features:

• Rated 90˚C wet or dry • Ripcord applied to all cables with jacket thickness of 60 mils or less • Meets CSA cold impact test at -40˚C • Meets ICEA and CSA cold bend test at -65˚C • Meets the crush and impact requirements of Type MC cable

Compliances:

Industry Compliances: • ICEA S-73-532 • ICEA S-95-658/NEMA WC70 • UL 44 Type XHHW-2 • UL 1277 Type TC-ER for 3 or more conductors • UL 1581 • CSA C22.2 No. 38 XLPE RW90 • CSA C22.2 No. 230 Type TC Flame Tests Compliances: • UL 1581 VW-1 • UL 1277 • IEEE 383 • CSA FT-4 Other Compliances: • EPA 40 CFR, Part 261 for leachable lead content per TCLP • OSHA acceptable

Packaging:

• Material cut to lengths and shipped on nonreturnable wood reels

Phone: 888-593-3355 www.generalcable.com


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.