SPEC 4150

January, 2008

EHTC

®

FR-EPR/HYP, Control, Unshielded 600V, UL Type TC (18 AWG/16 AWG)—E-2 Color Code Product Construction Conductor:

• 18 AWG and 16 AWG tinned, annealed copper per ASTM B33 • Class B stranding per ASTM B8

Insulation:

CATALOG NUMBER

COPPER MINIMUM AVG. MINIMUM AVG. WEIGHT NET WEIGHT INSULATION JACKET NOMINAL NO. COND. THICKNESS CABLE O.D. LBS/ OF SIZE COND. THICKNESS LBS/ COND. (AWG) STRAND inCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

18 AWG MULTI CONDUCTORS 366190* 343330* 343340* 343350* 343360* 343370* 343380* 343390* 343400* 343410* 343420* 343430* 343440* 343450*

2 Flat 2 3 4 5 7 9 10 12 15 19 25 30 37

18 18 18 18 18 18 18 18 18 18 18 18 18 18

7/.0152 7/.0152 7/.0152 7/.0152 7/.0152 7/.0152 7/.0152 7/.0152 7/.0152 7/.0152 7/.0152 7/.0152 7/.0152 7/.0152

366200* 343460* 343470* 343480* 343490* 343500* 343510* 343520* 343530* 343540* 343550* 343560* 343570* 343580*

2 Flat 2 3 4 5 7 9 10 12 15 19 25 30 37

16 16 16 16 16 16 16 16 16 16 16 16 16 16

7/.0192 7/.0192 7/.0192 7/.0192 7/.0192 7/.0192 7/.0192 7/.0192 7/.0192 7/.0192 7/.0192 7/.0192 7/.0192 7/.0192

0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025

0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64

0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.060 0.060

1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.52 1.52 1.52 1.52 1.52

.192 x .290 4.88 x 7.37

0.295 0.310 0.340 0.365 0.395 0.455 0.485 0.510 0.580 0.625 0.720 0.770 0.830

7.49 7.88 8.64 9.27 10.03 11.56 12.32 12.95 14.73 15.88 18.29 19.56 21.08

10 10 15 20 26 36 46 51 61 77 97 128 154 189

15 15 23 30 38 53 69 76 91 114 144 190 229 281

37 45 55 67 79 97 123 137 153 202 243 301 345 414

55 67 82 100 118 144 183 204 228 301 362 448 513 616

16 16 24 32 40 56 72 80 97 121 153 201 242 298

24 24 36 48 60 84 108 119 144 180 228 299 360 443

46 55 69 85 102 127 162 197 221 270 327 424 508 609

68 82 130 126 152 189 241 293 329 402 487 631 756 906

16 AWG MULTI CONDUCTORS 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025

0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64

0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.060 0.060 0.080 0.080

1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.52 1.52 1.52 1.52 1.52 2.03 2.03

.204 x .314 5.18 x 7.98

0.320 0.340 0.365 0.400 0.430 0.500 0.565 0.590 0.640 0.690 0.795 0.890 0.955

8.13 8.67 9.27 10.20 10.90 12.70 14.40 14.97 16.26 17.53 20.19 22.61 24.26

Dimensions and weights are nominal; subject to industry tolerances. *Non-stock item, minimum runs apply. Please consult Customer Service for price and delivery.

• Flame-retardant Ethylene Propylene Rubber (FR-EPR) Type II • Color-coded per ICEA Method 1; Table E-2 (does not include white or green)

Jacket:

• Low-lead Hypalon Chlorosulfonated Polyethylene (CSPE)/Elastomer blend

Print

• GENERAL CABLE® (WC) EHTC® XX/C XXAWG EPR/HYP UL TYPE TC 90˚ WET OR DRY CDRS BUR SUN RES 600V, DAY/MONTH/YEAR OF MFG SEQUENTIAL FOOTAGE MARK

Options:

• 2kV version • Bare copper conductors • Class C stranding • Insulated or uninsulated ground conductors • Overall shielded multi conductors • Duralox® aluminum interlocked armor • E-1 Color Code • Flame-retardant Polyvinyl Chloride (PVC) jacket • Thermoplastic Low-Smoke, Zero-Halogen (LSZH) jacket • Flame-retardant Thermoplastic Chloronated Polyethylene (CPE)—See FREP® Spec 4300 • Other constructions available upon request

Applications:

• In free air, raceways or direct burial • In wet or dry locations • At temperature as low as -35˚C • In Class I Division 2 industrial hazardous locations per NEC

Features:

• Rated at 90˚C wet or dry • Ripcord applied to all cables with jacket thickness of 60 mils or less • Excellent physical, thermal and electrical properties • Excellent moisture resistance • Excellent resistance to crush, compression cuts and heat deformation • Excellent flame resistance • Excellent low temperature cold bend characteristics • Good abrasion resistance • Low moisture absorption characteristics • “Heavy duty” rated per ICEA standards • Meets cold bend test at -35˚C

Compliances:

Industry Compliances: • UL 1277 Type TC • UL 1581 • ICEA S-73-532 • ICEA S-95-658/NEMA WC70 Flame Tests Compliances: • UL 1581 VW-1 • UL 1277 • IEEE 383 • IEEE 1202 • CSA FT-4 • ICEA T-29-520 Other Compliances: • EPA 40 CFR, Part 261 for leachable lead content per TCLP • OSHA acceptable

Packaging:

• Material cut to length and shipped on non-returnable wood reels

Phone: 888-593-3355 www.generalcable.com