Fitting instruction - UNU Shelves (H150-Series)

Page 1

400 600 450 150 150 5 150 150 5 150 5 150 5 300 5 300 5 300 5 5 150 150 1000 450 5 4 4 4 4 4 4 4 4 4 150 UNU SHELVES H150-SERIES PRODUCT DETAILS, TECHNICAL DETAILS AND FITTING INSTRUCTIONS frostdenmark.com ITEM NUMBERS: U4020, U4046, U4047, U4021, U4022, U4023, U4024 U4036 U4037 MATERIAL: ALUMINIUM DESIGNED BY BØNNELYCKE

SHELF 4020

150 mm

Aluminium Height: 150 mm Width: 150 mm Projection: 150 mm Shelf Thickness: 4 mm

SHELF 4046

400 mm

Aluminium Height: 150 mm Width: 400 mm Projection: 150 mm Shelf Thickness: 4 mm

Matt Black U4020-B

Matt White U4020-W

SHELF 4047

400 mm

Aluminium Height: 150 mm Width: 400 mm Projection: 300 mm Shelf Thickness: 4 mm

Matt Black U4046-B

Matt White U4046-W

SHELF 4021

600 mm

Aluminium Height: 150 mm Width: 600 mm Projection: 150 mm Shelf Thickness: 4 mm

Matt Black U4047-B

Matt White U4047-W

Matt Black U4021-B Matt White U4021-W

SHELF 4022

1000 mm

Aluminium Height: 150 mm Width: 1000 mm Projection: 150 mm Shelf Thickness: 4 mm

SHELF 4023

600 mm

Aluminium Height: 150 mm Width: 600 mm Projection: 300 mm Shelf Thickness: 4 mm

Matt Black U4022-B

Matt White U4022-W

Matt Black U4023-B

Matt White U4023-W

2 WWW.FROSTDENMARK.COM

SHELF 4024

1000 mm

Aluminium Height: 150 mm Width: 1000 mm Projection: 300 mm Shelf Thickness: 4 mm

SHELF 4036

600 mm

Aluminium Height: 150 mm Width: 600 mm Projection: 450 mm Shelf Thickness: 4 mm

Matt Black U4024-B

Matt White U4024-W

Matt Black U4036-B

Matt White U4036-W

SHELF 4037

1000 mm

Aluminium Height: 150 mm Width: 1000 mm Projection: 450 mm Shelf Thickness: 4 mm

ALSO AVAILABLE

SHELF CONNECTOR

Aluminium Diameter: Ø50 mm Projection: 12 mm Shelf Thickness: 4 mm

Matt Black U4037-B

Matt White U4037-W

Matt Black U4042-B

Matt White U4042-W

3 WWW.FROSTDENMARK.COM

OF U4020 MOUNTING OF U4046 & U4047

D 4 pcs. Ø8x38mm E 4 pcs. Ø5x40mm

STEP 1: Secure the mounting bar A on the wall as illustrated. Use four D wall plugs and E screws.

60

NOTE: The lower mounting bar B should only be mounted if the shelf is installed in public or any area with the risk of people removing the shelf.

STEP 1: Secure the mounting bar A on the wall as illustrated. Use six D wall plugs and E screws.

D 6 pcs. Ø8x38mm E 6 pcs. Ø5x40mm

NOTE: The lower mounting bar B should only be mounted if the shelf is installed in public or any area with the risk of people removing the shelf.

READY TO USE

4 WWW.FROSTDENMARK.COM
NOTE: Please use the amount of screws and plugs suitable for your walls and the intended load.
MOUNTING
STEP 2: Slide the Shelf C onto the mounting bracket A and B IN THE BOX
A
A B
B C C A B C A B C
A
B E D
All measurements are in milimeters All measurements are in milimeters 26 60 60 40 60 26 A B E D

STEP 1: Secure the mounting bar A on the wall as illustrated. Use twelve D wall plugs and E screws.

NOTE: Please use the amount of screws and plugs suitable for your walls and the intended load.

STEP 2: Slide the Shelf C onto the mounting bracket A and B .

D 12 pcs. Ø8x38mm E 12 pcs. Ø5x40mm D 8 pcs. Ø8x38mm E 8 pcs. Ø5x40mm

NOTE: Please use the amount of screws and plugs suitable for your walls and the intended load.

NOTE: The lower mounting bar B should only be mounted if the shelf is installed in public or any area with the risk of people removing the shelf.

READY TO USE

STEP 1: Secure the mounting bar A on the wall as illustrated. Use eight D wall plugs and E screws.

NOTE: The lower mounting bar B should only be mounted if the shelf is installed in public or any area with the risk of people removing the shelf.

READY TO

5 WWW.FROSTDENMARK.COM
STEP 2: Slide the Shelf C onto the mounting bracket A and B IN THE BOX IN THE BOX
MOUNTING OF U4022, U4024 & U4037
26
A D E B A B A B
A B
USE All measurements are in milimeters All measurements are in milimeters MOUNTING OF U4021, U4023 & U4036 A B C
60 80 80 60 60
C 60 60 60 280 280 B D E
C
A 26

FROST A/S

Headquarter & Showroom

Bavne Allé 32 8370 Hadsten Denmark +45 8761 0032 info@frost.dk

Flagship Showroom

Christian IX’s Gade 5 1111 Copenhagen Denmark +45 5172 6432 showroom-cph@frost.dk

frostdenmark.com

We are also to be found as frostdenmark on Facebook, Instagram, Pinterest and LinkedIn

CLEANING AND MAINTENANCE

Surfaces should be cleaned with a microfiber cloth, glass cleaner or other non abrasive and gentle agents.

ATTENTION:

Never use solvents or aggressive household cleaners like bleach, acids (e.g. descalers) or ammonia-based bathroom cleaner to clean the product. Steel wool and hard brushes can permanently damage the surface of the steel.

EXCLUSION OF LIABILITY

FROST accepts no liability whatsoever for damage to persons or property that occurs or has occurred as a result of improper installation or maintenance, particularly if the safety instructions and other points to note listed are not or have not been observed in full.

WARNING AND HAZARD NOTICES

Improper mounting or use can lead to accidents and serious injuries.