Installation Instructions FIELD

TITLE and DATA ENTRIES

EXPLANATION

*27

Powerline Carrier Device (X-10) House ID

Powerline Carrier devices require a House ID, identified in this field. Program Powerline Carrier devices in interactive modes ∗79, *80 and *81.

0=A 1=B 2=C 3=D 4=E 5=F

6=G 7=H 8=I 9=J # + 10 = K

# + 11 = L # + 12 = M # + 13 = N # + 14 = O # + 15 = P

Select the desired keypad display language.

*28

Language Select

*29

ECP Contact ID Output for ACM

*30

Make Partition 3 a Common Area Partition

0 = English 1 = Spanish 2 = Portuguese 0 = not used 1 = use Contact ID output on ECP

If selected, all messages programmed to go to the primary telephone line receiver will also be sent (in Contact ID format) to the connected Alternative Communication Media (ACM), such as a 7845i Internet/Intranet Communicator or AI4164RS/AI4164ETH Eureka Network Interface, or 7845C/7835C cellular radio (in selected countries). The data line is supervised as well as certain functions in a long range radio. If communication is lost or a trouble develops, an attempt will be made to send a message via both ACM and telephone to the central station. Program the ACM for device address 3. If selected, partition 3 functions as a common area partition, rather than as an independent partition.

0 = no (must be 0 if system uses zone type 82 - Blockschloss) 1 = yes, make partition 3 a common area partition

Zone Sounds & Timing FIELD

4-2

TITLE and DATA ENTRIES

EXPLANATION

*31

Single Alarm Sounding Per Zone

Select whether a zone going into alarm should sound more than once per armed period.

*32

Fire Alarm Sounder Timeout

*33

Bell (Siren) Timeout

*34

Exit Delay

(per armed period) 0 = no limit on alarm sounding per zone 1 = limit alarm sounding to once per arming period for a given zone 0 = yes; fire sounder timeout after time programmed in field ∗33 1 = no fire sounder timeout; continue sounding until manually turned off 0 = No timeout 1 = 1 min 2 = 2 min 3 = 3 min

4 = 4 min 5 = 8 min 6 = 16 min

00 - 96 = 0 - 96 seconds 97 = 120 seconds

Select whether fire alarm sounding expires after sounder timeout or remains until manually turned off.

This field determines whether the external sounder will shut off after time allotted, or continue until manually turned off.

The system waits the time entered before arming entry/exit zones. If the entry/exit door is left open after this time expires, an alarm will occur or the zone will be auto-bypassed, depending on the selection in field *88. Common area zones use same delay as partition 1.