Tab 08 - Switching Devices

Page 13

Switching Devices Safety Switches

8-13

February 2007

Technical Data and Specifications

Technical Data and Specifications

D

W

Dimensions Table 8-26. General-Duty, Plug Fuse, 120, 120/240 Volt, 1-, 2-Pole Solid Neutral, Single Throw Ampere Rating

NEMA 1 Dimensions in Inches (mm)

30

H

Height

Width

Depth

6.88 (174.8)

4.94 (125.5)

3.44 (87.4)

Table 8-27. General-Duty, Non-Fusible, 240 Volt, 3-Pole, Single Throw Ampere NEMA 1 Rating Dimensions in Inches (mm) Width (W)

Height (H)

Depth (D)

NEMA 3R Depth (D2)

Weight Lbs (kg)

D2

Dimensions in Inches (mm) Width (W)

Height (H)

Depth (D)

Depth (D2)

Weight Lbs (kg)

30

6.38 10.69 (162.1) (271.5)

6.88 3.75 (174.8) (95.2)

6 (2.724)

6.38 10.81 (162.1) (274.6)

6.88 3.75 (174.8) (95.2)

6 (2.724)

60

8.69 14.19 (220.7) (360.4)

7.38 4.21 9 (187.5) (106.9) (4.086)

8.69 14.38 (220.7) (365.3)

7.38 4.21 9 (187.5) (106.9) (4.086)

100

9.13 18.81 (231.9) (477.8)

7.38 4.23 12 (187.5) (107.4) (5.448)

9.13 19.25 (231.9) (489.0)

7.38 4.23 12 (187.5) (107.4) (5.448)

200

16.00 25.25 (406.4) (641.4)

11.25 6.14 48 16.00 25.50 (285.8) (156.0) (21.792) (406.4) (647.7)

11.25 6.14 55 (285.8) (156.0) (24.97)

400

23.00 44.75 (584.2) (1136.7)

12.63 7.27 100 (320.8) (184.7) (45.4)

23.00 45.19 (584.2) (1147.8)

12.63 7.27 105 (320.8) (184.7) (47.67)

600

52.25 24.00 (609.6) (1327.2)

14.25 8.95 130 (362.0) (227.3) (59.02)

24.00 52.70 (609.6) (1338.6)

14.25 8.95 135 (362.0) (227.3) (61.29)

Figure 8-1. NEMA 1-3R 30 – 100 Amperes General-Duty Non-Fusible and Fusible Single Throw Note: Figure is not applicable to plug fuse.

W

D

H

CL

Note: Dimensions are for estimating purposes only.

Table 8-28. General-Duty, Fusible, 240 Volt, 3-Pole Solid Neutral, Single Throw Ampere NEMA 1 Rating Dimensions in Inches (mm)

D2

NEMA 3R Weight Dimensions in Inches (mm) Lbs (kg) Width Height Depth Depth (W) (H) (D) (D2)

Weight Lbs (kg)

6.88 3.75 (174.8) (95.2)

6 (2.724)

6.38 10.81 (162.1) (274.6)

6.88 3.75 (174.8) (95.2)

6 (2.724)

14.19 (360.4)

7.38 4.21 (187.5) (106.9)

10 (4.54)

8.69 14.38 (220.7) (365.3)

7.38 4.21 10 (187.5) (106.9) (4.54)

9.13 (231.9)

18.81 (477.8)

7.38 4.23 (187.5) (107.4)

14 (6.356)

9.13 19.25 (231.9) (489.0)

7.38 4.23 14 (187.5) (107.4) (6.356)

200

16.00 (406.4)

24.75 (628.7)

11.25 6.14 (285.8) (156.0)

48 16.00 25.50 (21.792) (406.4) (647.7)

11.25 6.14 55 (285.8) (156.0) (24.97)

400

23.00 (584.2)

44.75 12.63 7.27 (1136.7) (320.8) (184.7)

110 (49.94)

23.00 45.19 (584.2) (1147.8)

12.63 7.27 115 (320.8) (184.7) (52.21)

600

24.00 (609.6)

52.25 14.25 8.95 (1327.2) (362.0) (227.3)

145 (65.83)

24.00 52.70 (609.6) (1338.6)

14.25 8.95 150 (362.0) (227.3) (68.1)

Width (W)

Height (H)

Depth (D)

30

6.38 (162.1)

10.69 (271.5)

60

8.69 (220.7)

100

Depth (D2)

Note: Dimensions are for estimating purposes only.

CA08101001E

For more information visit: www.eaton.com

Figure 8-2. NEMA 1-3R 200 – 600 Amperes General-Duty Non-Fusible and Fusible Single Throw

8


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.