How to order temp control uk

Page 1

Order your DME Temperature Control System How to order:

Controller

Wiring Suffix

Order examples: Intelligent 30-zone with standard cable INT 3048

MC

Smart Series II 10-zone with HAN48E STEP 1012 connector on tool side

H48E

page 2-3

Smart Series II Controllers

End user price in EUR. incl. cabinet, 2-zone touch-screen, 15A control card and 5m

cable.

No Cable

With Cable

STEP0204

2 x 15A

NC

€989

Suffix

€1.293

STEP0404

4 x 15A

NC

€1.324

Suffix

€1.627

STEP0606

6 x 15A

NC

€1.695

Suffix

€2.081

STEP0812

8 x 15A

NC

€2.169

Suffix

€2.658

STEP1012

10 x 15A

NC

€2.566

Suffix

€3.057

STEP1212

12 x 15A

NC

€2.869

Suffix

€3.361

STEP1418

14 x 15A

NC

€2.947

Suffix

€3.928

STEP1618

16 x 15A

NC

€3.462

Suffix

€4.444

STEP1818

18 x 15A

NC

€3.986

Suffix

€4.969

Intelligent Controllers

End user price in EUR. incl. cabinet, touch-screen HMI, 15A control card and 5m cable.

No Cable INT0612

6 x 15A

NC

€2.716

Suffix

€3.130

INT1212

12 x 15A

NC

€3.504

Suffix

€3.918

INT1824

18 x 15A

NC

€4.240

Suffix

€5.069

INT2424

24 x 15A

NC

€5.422

Suffix

€6.250

INT3048

30 x 15A

NC

€7.252

Suffix

€8.494

INT3648

36 x 15A

NC

€8.415

Suffix

€9.657

INT4248

42 x 15A

NC

€9.700

Suffix

€11.356

INT4848

48 x 15A

NC

€10.306

Suffix

€11.962

Beacon (for Intelligent 48)

Extras

www.dmeeu.com

With Cable

Trolley (for Intelligent 48)

REF

Price

REF

Price

INT48BEACON

€110

INT48TROLLEY

€275


Main Wiring Options Standard

DME

Suffix MC

Smart Series II 04 Std

Has one HAN16E with wiring at controller and tool as detailed below.

POWER

&

T/C

2

3

4

(L)

9

11

13

15

(N)

10

12

14

16

(+)

1

3

5

7

(-)

2

4

6

8

PIC-24-G MTC-5-G

Has one HAN24E with wiring at controller and tool as detailed below.

T/C

1

2

3

4

*

(L)

A1

A3

B1

B3

A5

(N)

A2

A4

B2

B4

B5

(+)

1

2

3

4

5

(-)

6

7

8

9

10

*not used

Smart Series II 06 DME

Wired as Smart Series II 06 Std at controller, and DME standard at tool as detailed below. Zone

Zone

HAN24E

&

Wired as StepUp 04 Std at controller, and DME standard at tool as detailed below. Zone

1

Smart Series II 06 Std

POWER

Smart Series II 04 DME

Zone

HAN16E

(L)

Suffix SC

1

2

3

4

5

6

1

3

5

7

9

11

(N)

2

4

6

8

10

12

(+)

13

15

17

19

21

23

(-)

14

16

18

20

22

24

PIC-24-G MTC-8-G

1

2

3

4

5

6

*

*

(L)

A1

A3

B1

B3

A5

C1

C3

D1

(N)

A2

A4

B2

B4

B5

C2

C4

D2

(+)

1

2

3

4

5

6

7

8

(-)

9

10

11

12

13

14

15

16

*not used

Smart Series II 12 Std - Intelligent 12/24/48 Std

Has two HAN24E connectors per 12 zones, one PWR and one T/C with wiring at controller and tool as detailed below.

T/C

Zone

1

2

3

4

5

6

7

8

9

10

11

12

(L)

1

2

3

4

5

6

7

8

9

10

11

12

(N)

13

14

15

16

17

18

19

20

21

22

23

24

(+)

1

2

3

4

5

6

7

8

9

10

11

12

(-)

13

14

15

16

17

18

19

20

21

22

23

24

Smart Series II 18 Std

Zone 1

POWER

T/C

HAN24E

(L)

(N)

(+)

(-)

1

13

1

13

Zone 13

POWER

PIC-24-G MTC-12-G

1

2

3

4

5

6

7

8

9

10

11

12

(L)

A1

A3

B1

B3

A5

C1

C3

D1

D3

C5

E1

E4

(N)

A2

A4

B2

B4

B5

C2

C4

D2

D4

D5

E2

E4

(+)

1

2

3

4

5

6

7

8

9

10

11

12

(-)

13

14

15

16

17

18

19

20

21

22

23

24

Smart Series II 18 DME

Has four HAN24E connectors, two PWR and two T/C with wiring at controller and tool as detailed below. HAN24E

Wired as Smart Series II 12 Std at controller, and DME standard at tool as detailed below (one PWR and one T/C per 12 zones)

Zone

HAN24E POWER

Smart Series II 12 DME - Intelligent 12/24/48 DME

Wired as Smart Series II 18 Std at controller, and DME standard at tool as detailed below.

T/C

PIC-24-G

(L)

(N)

(+)

(-)

1

13

1

13

MTC-12-G

PIC-24-G

(L)

(N)

(+)

(-)

Zone 1

A1

A2

1

13

Zone 13

MTC-12-G

(L)

(N)

(+)

(-)

A1

A2

1

13

Zone 2

2

14

2

14

Zone 14

2

14

2

14

Zone 2

A3

A4

2

14

Zone 14

A3

A4

2

14

Zone 3

3

15

3

15

Zone 15

3

15

3

15

Zone 3

B1

B2

3

15

Zone 15

B1

B2

3

15

Zone 4

4

16

4

16

Zone 16

4

16

4

16

Zone 4

B3

B4

4

16

Zone 16

B3

B4

4

16

Zone 5

5

17

5

17

Zone 17

5

17

5

17

Zone 5

A5

B5

5

17

Zone 17

A5

B5

5

17

Zone 6

6

18

6

18

Zone 18

6

18

6

18

Zone 6

C1

C2

6

18

Zone 18

C1

C2

6

18

Zone 7

7

19

7

19

not used

7

19

7

19

Zone 7

C3

C4

7

19

not used

C3

C4

7

19

Zone 8

8

20

8

20

not used

8

20

8

20

Zone 8

D1

D2

8

20

not used

D1

D2

8

20 21

Zone 9

9

21

9

21

not used

9

21

9

21

Zone 9

D3

D4

9

21

not used

D3

D4

9

Zone 10

10

22

10

22

not used

10

22

10

22

Zone 10

C5

D5

10

22

not used

C5

D5

10

22

Zone 11

11

23

11

23

not used

11

23

11

23

Zone 11

E1

E2

11

23

not used

E1

E2

11

23

Zone 12

12

24

12

24

not used

12

24

12

24

Zone 12

E3

E4

12

24

not used

E3

E4

12

24

Standard Cable Tool Ends

All cables have a top-entry hood with four pins for double lever housings. For 12 zones or more the standard connector is HAN24E and the tool end has female PWR and male T/C. Variants such as side-entry or 2-pin can be easily provided. For tools having other than HAN24E connectors please view some options shown overleaf.

DME Standard Tool Ends

All cables have A side-entry hood with two pins for single lever housings. The standard PWR connector is PIC-24-G and the T/C connectors are either MTC-5-G, MTC-8-G or MTC-12-G depending on the number of zones used. All are female gender at the tool end of the cable. For tools having other connectors please view some options shown overleaf.


Other cabling options* *available for the whole range

Suffix H10E

Option-HAN10E

Option-Combi

HAN24E

Zone 1

HAN10E

POWER (L)

(N)

Zone 1

1

9

Zone 2

2

10

HAN10E

Suffix CC

Re-wire any Smart Series II or Intelligent controllers to provide all of the connectors wired in PWR and T/C combined Combi style as detailed below. For controllers with 6 zones or more a 10% charge is added.

For Smart Series II 4 Std & Smart Series II 6 Std at controller with separate PWR and T/C connectors at the tool as detailed below.

POWER (N)

(+)

(-)

1

2

13

14

Zone 2

3

4

15

16

5

6

17

18

Zone 4

7

8

19

20

Zone 5

9

10

21

22

Zone 6

11

12

23

24

(L)

(N)

(+)

(-)

1

Power

HAN16E

POWER

(L)

(N)

16

Zone 1

1

9

Zone 7

1

(N) 9

2

10

Zone 8

2

10

Zone 7

Zone 1

1

9

Zone 8

Zone 2

2

10

Zone 9

5

6

17

18

Zone 2

Zone 10

7

8

19

20

Zone 3

3

11

Zone 9

3

11

15

14

(L)

(-)

4

13

HAN16E

(+)

3

2

Suffix H16E

Tool uses smaller HAN16E connectors. Wired as standard at controller. Provide Y-Cables with HAN24E at controller for each pair of smaller HAN16E at tool.

T/C

(L)

Zone 3

T/C

Option-HAN16E

Zone 3

3

11

Zone 3

3

11

Zone 4

4

12

Zone 4

4

12

Zone 11

9

10

21

22

Zone 4

4

12

Zone 10

4

12

13

Zone 12

11

12

23

24

Zone 5

5

13

Zone 11

5

13

Zone 6

6

14

Zone 12

6

14

not used

7

15

not used

7

15

not used

8

16

not used

8

16

Zone 5

5

13

Zone 5

5

Allows maximum of 5 zones

Suffix HMOD

Option-HanMOD

Tool-end has HAN Modular connector with combined PWR and T/C as detailed below. Wired as standard at controller. Provide Y-Cables with two HAN24E at controller for each HanMOD at tool.

Option-HAN48E

Suffix H48E

Tool-end has single HAN48E with Male PWR and Female T/C as detailed below. Wired as standard at controller. Provide Y-cable with two HAN24E at controller for each HAN48E at tool.

HAN16E

POWER & T/C

HanMOD

HAN48E

POWER & T/C

(L)

(N)

(+)

(-)

(L)

(N)

(+)

(-)

Zone 1

C1

C2

A1

A7

Zone 1

1

13

1

13

Zone 2

C3

C4

A2

A8

Zone 2

2

14

2

14

Zone 3

3

15

3

15

Zone 4

4

16

4

16

Zone 5

5

17

5

17

Zone 6

6

18

6

18

Zone 7

7

19

7

19

Zone 8

8

20

8

20

Zone 9

9

21

9

21

Zone 10

10

22

10

22

Zone 11

11

23

11

23

Zone 12

12

24

12

24

Zone 3

C5

C6

A3

A9

Zone 4

D1

D2

A4

A10

Zone 5

D3

D4

A5

A11

Zone 6

D5

D6

A6

A12

Zone 7

E1

E2

B1

B7

Zone 8

E3

E4

B2

B8

Zone 9

E5

E6

B3

B9

Zone10

F1

F2

B4

B10

Zone11

F3

F4

B5

B11

Zone12

F5

F6

B6

B12

T/C

HAN16E

T/C

(+)

(-)

(+)

Zone 1

1

9

Zone 7

1

9

Zone 2

2

10

Zone 8

2

10

Zone 3

3

11

Zone 9

3

11

Zone 4

4

12

Zone 10

4

12

Zone 5

5

13

Zone 11

5

13

Zone 6

6

14

Zone 12

6

14

not used

7

15

not used

7

15

not used

8

16

not used

8

16

Other Options?

We can accommodate any other wiring standard not detailed here. However, any change request, that needs a change to the connectors or wiring within the controller, does attract a 10% surcharge.

(-)


Create your own cabling option here If you require non-standard cables and/or connectors not previously listed then please provide the following information (if available, please supply a tool drawing as well). Company ...........................................

DME Contact .....................................

Address ..............................................

Controller Type

Smart Series II

Intelligent

............................................................

Maximum No. of zones

4 6 12 18

12 24 48

............................................................ Contact ............................................... Tel: ...................................................... Fax: ..................................................... Email: .................................................

PWR Cable

Cable Length (Standard is 15ft) Are Code pins required

Yes/No

T/C Cable

Combined PWR & T/C

Controller End Connector (Standard is HAN24E) Top or Side Entry Hood? (Standard is Top Entry) Tool End Connector (Standard is HAN24E) Top or Side Entry Hood (Standard is Side Entry) Pins for SIngle or Double Lever (Standard is Double Lever) Are Mould Plugs Required?

Yes/No

Yes/No

How are Zones Wired?

UK

☎ +44 2071 3300 37

dme_uk@dmeeu.com

www.dmeeu.com

Export

☎ +32 15 21 50 17

dme_export@dmeeu.com

Yes/No


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.