Order your DME Temperature Control System How to order:
Controller
Wiring Suffix
Order examples: Intelligent 30-zone with standard cable INT 3048
MC
Smart Series II 10-zone with HAN48E STEP 1012 connector on tool side
H48E
page 2-3
Smart Series II Controllers
End user price in EUR. incl. cabinet, 2-zone touch-screen, 15A control card and 5m
cable.
No Cable
With Cable
STEP0204
2 x 15A
NC
€989
Suffix
€1.293
STEP0404
4 x 15A
NC
€1.324
Suffix
€1.627
STEP0606
6 x 15A
NC
€1.695
Suffix
€2.081
STEP0812
8 x 15A
NC
€2.169
Suffix
€2.658
STEP1012
10 x 15A
NC
€2.566
Suffix
€3.057
STEP1212
12 x 15A
NC
€2.869
Suffix
€3.361
STEP1418
14 x 15A
NC
€2.947
Suffix
€3.928
STEP1618
16 x 15A
NC
€3.462
Suffix
€4.444
STEP1818
18 x 15A
NC
€3.986
Suffix
€4.969
Intelligent Controllers
End user price in EUR. incl. cabinet, touch-screen HMI, 15A control card and 5m cable.
No Cable INT0612
6 x 15A
NC
€2.716
Suffix
€3.130
INT1212
12 x 15A
NC
€3.504
Suffix
€3.918
INT1824
18 x 15A
NC
€4.240
Suffix
€5.069
INT2424
24 x 15A
NC
€5.422
Suffix
€6.250
INT3048
30 x 15A
NC
€7.252
Suffix
€8.494
INT3648
36 x 15A
NC
€8.415
Suffix
€9.657
INT4248
42 x 15A
NC
€9.700
Suffix
€11.356
INT4848
48 x 15A
NC
€10.306
Suffix
€11.962
Beacon (for Intelligent 48)
Extras
www.dmeeu.com
With Cable
Trolley (for Intelligent 48)
REF
Price
REF
Price
INT48BEACON
€110
INT48TROLLEY
€275
Main Wiring Options Standard
DME
Suffix MC
Smart Series II 04 Std
Has one HAN16E with wiring at controller and tool as detailed below.
POWER
&
T/C
2
3
4
(L)
9
11
13
15
(N)
10
12
14
16
(+)
1
3
5
7
(-)
2
4
6
8
PIC-24-G MTC-5-G
Has one HAN24E with wiring at controller and tool as detailed below.
T/C
1
2
3
4
*
(L)
A1
A3
B1
B3
A5
(N)
A2
A4
B2
B4
B5
(+)
1
2
3
4
5
(-)
6
7
8
9
10
*not used
Smart Series II 06 DME
Wired as Smart Series II 06 Std at controller, and DME standard at tool as detailed below. Zone
Zone
HAN24E
&
Wired as StepUp 04 Std at controller, and DME standard at tool as detailed below. Zone
1
Smart Series II 06 Std
POWER
Smart Series II 04 DME
Zone
HAN16E
(L)
Suffix SC
1
2
3
4
5
6
1
3
5
7
9
11
(N)
2
4
6
8
10
12
(+)
13
15
17
19
21
23
(-)
14
16
18
20
22
24
PIC-24-G MTC-8-G
1
2
3
4
5
6
*
*
(L)
A1
A3
B1
B3
A5
C1
C3
D1
(N)
A2
A4
B2
B4
B5
C2
C4
D2
(+)
1
2
3
4
5
6
7
8
(-)
9
10
11
12
13
14
15
16
*not used
Smart Series II 12 Std - Intelligent 12/24/48 Std
Has two HAN24E connectors per 12 zones, one PWR and one T/C with wiring at controller and tool as detailed below.
T/C
Zone
1
2
3
4
5
6
7
8
9
10
11
12
(L)
1
2
3
4
5
6
7
8
9
10
11
12
(N)
13
14
15
16
17
18
19
20
21
22
23
24
(+)
1
2
3
4
5
6
7
8
9
10
11
12
(-)
13
14
15
16
17
18
19
20
21
22
23
24
Smart Series II 18 Std
Zone 1
POWER
T/C
HAN24E
(L)
(N)
(+)
(-)
1
13
1
13
Zone 13
POWER
PIC-24-G MTC-12-G
1
2
3
4
5
6
7
8
9
10
11
12
(L)
A1
A3
B1
B3
A5
C1
C3
D1
D3
C5
E1
E4
(N)
A2
A4
B2
B4
B5
C2
C4
D2
D4
D5
E2
E4
(+)
1
2
3
4
5
6
7
8
9
10
11
12
(-)
13
14
15
16
17
18
19
20
21
22
23
24
Smart Series II 18 DME
Has four HAN24E connectors, two PWR and two T/C with wiring at controller and tool as detailed below. HAN24E
Wired as Smart Series II 12 Std at controller, and DME standard at tool as detailed below (one PWR and one T/C per 12 zones)
Zone
HAN24E POWER
Smart Series II 12 DME - Intelligent 12/24/48 DME
Wired as Smart Series II 18 Std at controller, and DME standard at tool as detailed below.
T/C
PIC-24-G
(L)
(N)
(+)
(-)
1
13
1
13
MTC-12-G
PIC-24-G
(L)
(N)
(+)
(-)
Zone 1
A1
A2
1
13
Zone 13
MTC-12-G
(L)
(N)
(+)
(-)
A1
A2
1
13
Zone 2
2
14
2
14
Zone 14
2
14
2
14
Zone 2
A3
A4
2
14
Zone 14
A3
A4
2
14
Zone 3
3
15
3
15
Zone 15
3
15
3
15
Zone 3
B1
B2
3
15
Zone 15
B1
B2
3
15
Zone 4
4
16
4
16
Zone 16
4
16
4
16
Zone 4
B3
B4
4
16
Zone 16
B3
B4
4
16
Zone 5
5
17
5
17
Zone 17
5
17
5
17
Zone 5
A5
B5
5
17
Zone 17
A5
B5
5
17
Zone 6
6
18
6
18
Zone 18
6
18
6
18
Zone 6
C1
C2
6
18
Zone 18
C1
C2
6
18
Zone 7
7
19
7
19
not used
7
19
7
19
Zone 7
C3
C4
7
19
not used
C3
C4
7
19
Zone 8
8
20
8
20
not used
8
20
8
20
Zone 8
D1
D2
8
20
not used
D1
D2
8
20 21
Zone 9
9
21
9
21
not used
9
21
9
21
Zone 9
D3
D4
9
21
not used
D3
D4
9
Zone 10
10
22
10
22
not used
10
22
10
22
Zone 10
C5
D5
10
22
not used
C5
D5
10
22
Zone 11
11
23
11
23
not used
11
23
11
23
Zone 11
E1
E2
11
23
not used
E1
E2
11
23
Zone 12
12
24
12
24
not used
12
24
12
24
Zone 12
E3
E4
12
24
not used
E3
E4
12
24
Standard Cable Tool Ends
All cables have a top-entry hood with four pins for double lever housings. For 12 zones or more the standard connector is HAN24E and the tool end has female PWR and male T/C. Variants such as side-entry or 2-pin can be easily provided. For tools having other than HAN24E connectors please view some options shown overleaf.
DME Standard Tool Ends
All cables have A side-entry hood with two pins for single lever housings. The standard PWR connector is PIC-24-G and the T/C connectors are either MTC-5-G, MTC-8-G or MTC-12-G depending on the number of zones used. All are female gender at the tool end of the cable. For tools having other connectors please view some options shown overleaf.
Other cabling options* *available for the whole range
Suffix H10E
Option-HAN10E
Option-Combi
HAN24E
Zone 1
HAN10E
POWER (L)
(N)
Zone 1
1
9
Zone 2
2
10
HAN10E
Suffix CC
Re-wire any Smart Series II or Intelligent controllers to provide all of the connectors wired in PWR and T/C combined Combi style as detailed below. For controllers with 6 zones or more a 10% charge is added.
For Smart Series II 4 Std & Smart Series II 6 Std at controller with separate PWR and T/C connectors at the tool as detailed below.
POWER (N)
(+)
(-)
1
2
13
14
Zone 2
3
4
15
16
5
6
17
18
Zone 4
7
8
19
20
Zone 5
9
10
21
22
Zone 6
11
12
23
24
(L)
(N)
(+)
(-)
1
Power
HAN16E
POWER
(L)
(N)
16
Zone 1
1
9
Zone 7
1
(N) 9
2
10
Zone 8
2
10
Zone 7
Zone 1
1
9
Zone 8
Zone 2
2
10
Zone 9
5
6
17
18
Zone 2
Zone 10
7
8
19
20
Zone 3
3
11
Zone 9
3
11
15
14
(L)
(-)
4
13
HAN16E
(+)
3
2
Suffix H16E
Tool uses smaller HAN16E connectors. Wired as standard at controller. Provide Y-Cables with HAN24E at controller for each pair of smaller HAN16E at tool.
T/C
(L)
Zone 3
T/C
Option-HAN16E
Zone 3
3
11
Zone 3
3
11
Zone 4
4
12
Zone 4
4
12
Zone 11
9
10
21
22
Zone 4
4
12
Zone 10
4
12
13
Zone 12
11
12
23
24
Zone 5
5
13
Zone 11
5
13
Zone 6
6
14
Zone 12
6
14
not used
7
15
not used
7
15
not used
8
16
not used
8
16
Zone 5
5
13
Zone 5
5
Allows maximum of 5 zones
Suffix HMOD
Option-HanMOD
Tool-end has HAN Modular connector with combined PWR and T/C as detailed below. Wired as standard at controller. Provide Y-Cables with two HAN24E at controller for each HanMOD at tool.
Option-HAN48E
Suffix H48E
Tool-end has single HAN48E with Male PWR and Female T/C as detailed below. Wired as standard at controller. Provide Y-cable with two HAN24E at controller for each HAN48E at tool.
HAN16E
POWER & T/C
HanMOD
HAN48E
POWER & T/C
(L)
(N)
(+)
(-)
(L)
(N)
(+)
(-)
Zone 1
C1
C2
A1
A7
Zone 1
1
13
1
13
Zone 2
C3
C4
A2
A8
Zone 2
2
14
2
14
Zone 3
3
15
3
15
Zone 4
4
16
4
16
Zone 5
5
17
5
17
Zone 6
6
18
6
18
Zone 7
7
19
7
19
Zone 8
8
20
8
20
Zone 9
9
21
9
21
Zone 10
10
22
10
22
Zone 11
11
23
11
23
Zone 12
12
24
12
24
Zone 3
C5
C6
A3
A9
Zone 4
D1
D2
A4
A10
Zone 5
D3
D4
A5
A11
Zone 6
D5
D6
A6
A12
Zone 7
E1
E2
B1
B7
Zone 8
E3
E4
B2
B8
Zone 9
E5
E6
B3
B9
Zone10
F1
F2
B4
B10
Zone11
F3
F4
B5
B11
Zone12
F5
F6
B6
B12
T/C
HAN16E
T/C
(+)
(-)
(+)
Zone 1
1
9
Zone 7
1
9
Zone 2
2
10
Zone 8
2
10
Zone 3
3
11
Zone 9
3
11
Zone 4
4
12
Zone 10
4
12
Zone 5
5
13
Zone 11
5
13
Zone 6
6
14
Zone 12
6
14
not used
7
15
not used
7
15
not used
8
16
not used
8
16
Other Options?
We can accommodate any other wiring standard not detailed here. However, any change request, that needs a change to the connectors or wiring within the controller, does attract a 10% surcharge.
(-)
Create your own cabling option here If you require non-standard cables and/or connectors not previously listed then please provide the following information (if available, please supply a tool drawing as well). Company ...........................................
DME Contact .....................................
Address ..............................................
Controller Type
Smart Series II
Intelligent
............................................................
Maximum No. of zones
4 6 12 18
12 24 48
............................................................ Contact ............................................... Tel: ...................................................... Fax: ..................................................... Email: .................................................
PWR Cable
Cable Length (Standard is 15ft) Are Code pins required
Yes/No
T/C Cable
Combined PWR & T/C
Controller End Connector (Standard is HAN24E) Top or Side Entry Hood? (Standard is Top Entry) Tool End Connector (Standard is HAN24E) Top or Side Entry Hood (Standard is Side Entry) Pins for SIngle or Double Lever (Standard is Double Lever) Are Mould Plugs Required?
Yes/No
Yes/No
How are Zones Wired?
UK
☎ +44 2071 3300 37
dme_uk@dmeeu.com
www.dmeeu.com
Export
☎ +32 15 21 50 17
dme_export@dmeeu.com
Yes/No