LANA Anaesthetic Machine Features

• Lower dead space than conventional connectors • Short polycarbonate endotracheal tube connectors: 8, 20, 25, 30, 35 and 40mm. Other sizes on request • The LANA breathing circuit is pressure tested to eliminate leaks. This enables low fresh gas flow rates (2-3 l/min) to be used in large animals down to 0.1 l/min in small animals • The LANA machine can be used in the field as a TRANSPORTABLE unit • For field use a portable medical oxygen cylinder can be carried in the trolley cylinder support (supplied) • Oxygen flush (by-pass) valve. The KDK80 Flow Meter has a range of ............0-8 ls of oxygen per minute with click settings at 0, 1, 2, 3, 4, 6 and 8 l/min. The oxygen flush enters the breathing circuit beyond the vaporizer and operates at all settings for rapid filling of the breathing bag

For further information call 1300 785 401 - Northern Branch 1300 785 405 - Southern Branch Email: info@dlc.com.au www.dlc.com.au


LANA ANAESTHETIC MACHINE LANA - a combined anaesthetic machine for large and small animals. Apparently Less resistance to breathing than conventional circuits. The LANA hose-in-hose breathing circuit replaces conventional bulky twin hoses. The uni-directional silicone valves are incorporated within the 52 mm inner and the 88 mm outer hose. All hoses are reinforced by a stainless steel coil and are autoclavable. Short polycarbonate endotracheal tube .connectors: 18, 20, 25, 30, 25 and 40 mm. Other sizes available on request. Significantly lower cost of maintenance of anaesthesia. The LANA breathing circuit is pressure tested to eliminate leaks. This enables low fresh gas flow rates (2-3 l/min) to be used in large animals down to 0.1 l/min in small animals. The LANA machine can be used in the field as a TRANSPORTABLE unit. •

Lower dead space than conventional connectors

Short polycarbonate endotracheal tube connectors: .8, 20, 25, 30, 35 and 40mm. Other sizes on request

The LANA breathing circuit is pressure tested to eliminate leaks. This enables low fresh gas flow rates (2-3 l/min) to be used in large animals down to 0.1 l/min in small animals

The LANA machine can be used in the field as a TRANSPORTABLE unit

For field use a portable medical oxygen cylinder can be carried in the trolley cylinder support (supplied)

Oxygen flush (by-pass) valve. The KDK80 Flow Meter has a range of .0-8 ls of oxygen per minute with click settings at 0, 1, 2, 3, 4, 6 and .8 l/min. The oxygen flush enters the breathing circuit beyond the vaporizer and operates at all settings for rapid filling of the breathing bag

Anaesthetic Machine includes • Mobile stand complete with trolley and cylinder support

110033 Small Animal Setup 110034 Large Animal Setup

Hose-in-hose breathing circuit for large animals

Occluding plug for hose-in-hose assembly

Endotracheal tube connectors 18, 20,25, 30, 35 and 40mm

Large carbon dioxide absorber, capacity 4.2kg of soda lime (lasting approx. 3 hours in a 500kg animal). 30 l breathing bag. The LANA carbon dioxide absorber is filled and emptied within 1 to 2 minutes through a 50mm wide opening without detaching it from the machine and the absorber can rotate 180 degree for easy emptying

• Units do not include vaporiser or key filler 110033.......... LANA Anaesthetic Unit KOM VOC Roto Flush Small Animal Setup 110034.......... LANA Anaesthetic Unit KOM VOC Roto Flush Large Animal Setup

For further information please call:

110013 Key Filler for Vaporiser

110012 New Tec 3 Isoflurane Vaporiser

SOUTHERN OFFICE:

NORTHERN OFFICE:

PO Box 4438, 17-19 Horne St, Hoppers Crossing, VIC, 3029

PO Box 833, Unit 6/1 Lear-Jet Dr, Caboolture, QLD, 4510

Phone: 03 9360 9700 Fax: 03 9360 9994 Toll Free: 1300 785 405 Email: info@dlc.com.au

Phone: 07 5428 3666 Fax: 07 5428 3777 Toll Free: 1300 785 405 Email: qld@dlc.com.au


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.