ATMOS ENT catalogue 2012 / 2013 - english

Page 136

| ATMOS Diagnostics | ATMOS Diagnostic Cube

ATMOS Diagnostic Cube

ATMOS Diagnostic Cube Basic module for integration of diagnostic modules including Windows PC software and viewer software. Technical data: Mains voltage 100 -240 V, 50/60 Hz

REF ❁ 512.0000.0

Included in delivery: Software CD, power supply, IEC mains cable, operating instructions PC is not included in delivery! System requirements: operating system Windows XP up from SP2 or Windows 7(32/64 bit), free hard disk capacity: 10 MB, processor performance: min. 1 GHz, available internal memory: 1 GB RAM, graphics resolution min. 600 x 800, at least 2 USB-2-port

Diagnostic modules for integration in ATMOS Diagnostic Cube

Module Sono 31 ➀ A-scan diagnostic module for integration into the ATMOS Diagnostic Cube. Specification: Individual amplification parameters for sinus maxillaris and frontalis. Operation via foot switch - please order separately. Technical data: Ultrasound frequency: 3.5 MHz, pulse frequency 100 Hz, max. amplification: 80 dB

❁ 512.1200.0

Included in delivery: Probe support Sono, ultrasonic probe, detachable probe cable (2 m), ultrasonic gel (bottle 250 ml) Foot switch is not included in delivery, please order separately!

Module Tymp 31 ➁ Tympanometry diagnostic module for integration into the ATMOS Diagnostic Cube. Specification: Compliance measurement, peak, volume, stapedius reflex measurement, ipsi lateral, eustachian tube function test Technical data: Probe tone: 226, 678, 1000 Hz with 85 dB SPL, Stapedius reflex: 500 ,1000, 2000, 4000 Hz with 75, 85, 95 dB SPL, pressure: +200 -600 da Pa

❁ 512.1100.0

Included in delivery: Probe support Tymp, tympanometry probe, set of earplugs

Module Tymp 31 Basic Tympanometry diagnostic module for integration into the ATMOS Diagnost with reflex decay test Specification: Compliance measurement, peak, volume, stapedius reflex measurement, ipsi lateral, eustachian tube function test, reflex decay test Technical data: Probe tone: 226, 678, 1000 Hz with 85 dB SPL, Stapedius reflex: 500 ,1000, 2000, 4000 Hz , with 75, 85, 95 dB SPL pressure: +200 -600 da Pa Included in delivery: Probe support Tymp, tympanometry probe, set of earplugs

Please contact us via: ENT@atmosmed.com | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 136

❁ 512.1700.0


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.