AIXPLORER MACH 30

Page 1

U LT R A FA S T T M I N T E L L I G E N C E

A POWERFUL U LTR ASO UN D SY STEM FOR BREAST I M AG I N G


AIXPLORER MACH 30 Addressing your expectations with UltraFast™ innovations

Aixplorer MACH 30 ultrasound system - powered by the next generation of UltraFast™ imaging - leverages 10 years of clinical expertise to help you handle routine to comprehensive breast exams with ease and confidence. By analyzing your exam workflow, Aixplorer MACH 30 was designed to maximize comfort and drive efficiency in a busy practice thanks to its ease of use and streamlined ergonomics. The exceptional image quality of the Aixplorer MACH 30 combined with access to advanced capabilities delivers the level of premium performance you expect and patients deserve.

0 2


DESIGNED TO BE T H E N E W S TA N D A R D Enhanced productivity and visual comfort for optimal per formance and workflow

1. Widescreen 23” Full HD monitor

3. Intuitive control panel with revolutionary SonicPad

1

Enhanced image uniformity, deeper blacks and refined detail

Improved user experience and workflow

2. Large 15” Full HD touch display More flexibility to define your workflow 2

SONICPADTM Focus on what you see, not on what you do 3 SuperSonic Imagine is the first to introduce a multi-touch track-pad on an ultrasound device. Learning this new paradigm is effortless — intuitive gestures are unconsciously encoded in your muscle memory — leading to maximum efficiency and exam time reduction up to 32%.*

4. Low noise level, optimized cooling fan architecture Reduced noise for all environments

4

Shortcut gestures and application specific user interactions allow you to reduce hand and arm movements; resulting in a decrease of up to 72% for a breast exam.

5. Reduced footprint Suitable for any practice 5

Reduce time spent on image acquisition and spend more time on image interpretation to provide increased diagnostic confidence and deliver patient answers faster.

0

* Comparative study conducted by SuperSonic Imagine on 30 exams in breast, thyroid and liver (2018).

3


PUSHING THE BOUNDARIES OF BREAST IMAGING Image quality and innovative modes for dignostic confidence

The innovative transducer designs and powerful capabilities of software-based architecture are optimizing signal-to-noise ratio at each step of signal processing. SonicPure, excellent B-mode image quality with incredible definition in both fundamental and harmonic imaging modes. • Optimized penetration settings to visualize structures at variable depths and in dense breasts • SuperCompound: fast compounding for smoother images with reduced speckle • SuperRes: enhanced delineation of structures to improve lesion conspicuity • TissueTuner: clear images obtained by matching the speed of sound to tissue density • AutoTGC: automatic optimization of the gain for the entire image

ULTRAFAST IMAGING The UltraFast™ technology — first introduced on Aixplorer® in 2009 — allows for the capture of images 200 times faster than conventional ultrasound. In addition to obtaining genuine diagnostic B-mode information, this unmatched technology has led to several breakthroughs that offer new possibilities for patient management: real-time elastography ShearWave™ PLUS, TriVu, Angio PL.U.S. and Needle PL.U.S. The next generation of the UltraFast™ technology — introduced on Aixplorer MACH 30 — has 5x more computing power*.

SonicPure: Excellent lesion conspicuity

* In comparison with previous Aixplorer® products. 0 4

SonicPure: Exceptional tissue differentiation


Supported by our family of lightweight and ergonomic transducers optimized for all exams, Aixplorer MACH 30 platform offers premium level of performance for breast imaging.

L18-5 transducer: the reference for imaging of subtle anatomical details in all breast morphologies.

LH20-6 transducer: ultra high resolution imaging of superficial lesions and the retro-areal region.

L10-2 transducer: optimized for imaging at greater depths.

LV16-5 linear volumetric transducer: freehand 3D imaging**.

Designed for breast specialists requirements, a portfolio of additional features is available to ensure full integration into routine workflow: • Extensive selection of annotations and body markers • Dedicated breast presets and measurements • Integrated BI-RADS™ classification tool • Full DICOM modalities suite, incl. native data query and retrieve (ultrasound, mammography…) • Configurable reporting page • Compatible with CIVCO biopsy accessories and kits

** Available soon.

0 5


VA L U E B A S E D I N N O VAT I O N S IN BREAST IMAGING Evidence based outcomes and improving the patient experience

Over the years, SuperSonic Imagine introduced several innovative imaging modes — made possible by its UltraFast™ technology. These innovations integrate with routine workflow, to deliver added value into breast imaging and improve patient management.

ShearWave™ PLUS ShearWave Elastography (SWE) from SuperSonic Imagine is the only technique capable of visualizing, analyzing and quantifying the tissue stiffness in real-time, on all transducers. This non-invasive approach remains reliable and highly reproducible in 2D and 3D.

Key attributes: • Large region of interest SWE PLUS • Increased SWE PLUS frame rates • Accelerated filling of the SWE PLUS box • Increased penetration to visualize deep lesions • Preserving the quality of the B-mode

ered by Pow

th

e

un

gy

ULTRAFAST INNOVATION iq u e t e c h n ol

o

REAL-TIME SHEARWAVE™ ELASTOGRAPHY SuperSonic Imagine’s proprietary shear wave-based elastography technology is the most clinically studied elastography in its category. With over 150 publications in peer-reviewed medical journals, SWE has been proven to be a complementary tool for: • Breast lesion diagnosis and characterization1 • Biopsy planning2 and treatment • Therapy monitoring3 and prognostics These extensive clinical studies have demonstrated: • Better discrimination between probably benign lesions (BIRADS 3) and suspicious lesions (BIRADS 4), thus reducing the number of false positives (specificity increased from 61% to 78%)4 thanks to additional SWE criteria • Improved lesion localization thanks to SWE modality on 2nd look ultrasound exams after MRI5 1, 4 - Berg WA et al. Radiology. 2012 Feb; 262(2):435-49. | 2 - Mullen R et al. Clin Radiology. 2014 Dec; 69(12):1259-63. 3 - Lee SH et al. Ann Surg Oncol. 2015 Dec; 22 Suppl 3:376-84. | 5 - Plecha DM et al. Radiology. 2014 Sep ; 272(3) :657-64. 0 6


Angio PL.U.S. Based on plane wave imaging technology, Angio PL.U.S. is an ultrasensitive color mode that offers enhanced visualization of blood flow. Angio PL.U.S. is the solution for an advanced exploration of the axillary region and the evaluation of lymph nodes. ered by Pow

th

e

un

gy

ULTRAFAST INNOVATION iq u e t e c h n ol

o

TriVu TriVu is a real-time imaging mode that allows you to display simultaneously morphologic (B-mode), stiffness (SWE PLUS) and flow information (equivalent to Angio PL.U.S.), all in the same image. TriVu is the answer to confident and timely diagnosis of suspect breast lesions. ered by Pow

th

e

un

gy

ULTRAFAST INNOVATION iq u e t e c h n ol

o

NEW ! Needle PL.U.S. Needle PL.U.S. addresses the challenge of limited needle visibility and the need to predict the needle trajector y. This real-time imaging mode allows you to perform biopsies with precision and confidence.

ered by Pow

th

e

un

gy

ULTRAFAST INNOVATION iq u e t e c h n ol

o

0 7


SUPERSONICIMAGINE.COM

SuperSonic Imagine

HQ / Europe, Middle East and Africa: +33 (0)4 42 99 24 24 North America: +1 (954) 660 3528 China: +86 10 85861023/2951/2971 contacts@supersonicimagine.com

Indications for Use: The SuperSonic Imagine Aixplorer MACH® 30 ultrasound diagnostic system and transducers are intended for general purpose pulse echo ultrasound imaging, Doppler fluid flow analysis of the human body, and soft tissue elasticity imaging. The Aixplorer MACH® 30 ultrasound diagnostic system is indicated for use in the following applications, for imaging and measurement of anatomical structures: Abdominal, Small Organs, Musculoskeletal, Superficial Musculoskeletal, Vascular, Peripheral Vascular, OB-GYN, Pelvic, Pediatric, Trans-rectal, Trans-vaginal, Urology, Neonatal/Adult Cephalic and Noninvasive Cardiac. In addition, the SuperSonic Imagine Aixplorer MACH® 30 ultrasound diagnostic system and associated transducers are intended for: measurements of abdominal anatomical structures; measurements of broadband shear wave speed, and tissue stiffness in internal structures of the liver and the spleen; measurements of brightness ratio between liver and kidney; visualization of abdominal vascularization, microvascularization and perfusion; quantification of abdominal vascularization and perfusion. The shear wave speed and stiffness measurements, the brightness ratio, the visualization of vascularization, microvascularization and perfusion, the quantification of vascularization and perfusion may be used as an aid to clinical management of adult and pediatric patients with liver disease. It is intended for use by a licensed personnel qualified to direct the use of the medical ultrasound devices. CE certificate no. 26415, FDA cleared - K180572. MKG.EC.286 © SuperSonic Imagine – July 2019.