Swissflow: Catalog

Page 1

Flow meter SF800

The patented SF800 technology is the basis for the highgrade fluid flow meters. It makes a constant reliable high-accuracy flow measurement throughout a large flow rate (0,5-20 l/min) possible.

One of the biggest advantages of the SF800 sensors is that because of the resistance-free working-principle (the rotor floats in the medium) the SF-800 fluid flow meters are not subjected to wear. To prevent any leaking, the SF-800 is sealed by ultrasonic sound waves.

On request, an additional protection for the electronics in the form of an added silicone-layer is possible. Because solid particles and/or contaminated medium can damage the sensor or influence the measurements, we advise the use of a filter (20 micron); if necessary these filters can be provided as well.

Working Principle The patented SF800 technology is the basis for these high-graded flow meters. The geometry of the rotor housing (causing a radial flow in) in combination with the light weight Vectra rotor (0,04 grams) makes the rotor float in the medium. Because the rotor floats there is the measurement process is nearly resistance-free, guaranteeing high accuracy, durability and linearity.

An integrated PCB emits an infrared signal, which is interrupted by the three blades of the rotor. SMD components transform the interrupted signal into a pulse. Because of the construction of the rotor housing, the SF800 flow sensors are practically insensible to high pressure.

The materials used (PVDF and Vectra) are to a great extent chemical-resistant and temperaturedurable. Contrary to many other fluid flow measurement systems, the SF800 sensors do not have to be calibrated. The limited number of parts and intelligent design results in product with infinite application possibilities and an excellent priceperformance ratio.

Instructions for installation and use Before putting the flow-meter into operation, please note the following:

1. 2. 3. 4. 5. 6. 7.

8. 9.

10. 11.

Hose discharges may not be subjected to pressure when the flow meter is put into operation. Medium-supply lines must be thoroughly cleaned before use. Use of a 20 (Micron) pre-filter is recommended. Solid particles or contamination in the medium may damage the flow meter and/or influence the measurement results. IMPORTANT: WATCH ARROW ON FLOW METER TO INSTALL IT IN CORRECT FLOW DIRECTION. Once the flow meter has been installed, the system should be filled slowly, to avoid air damaging the rotor. Hook up electronic connector to the flow meter. Make sure that the electrical connections have been hooked up as indicated on this diagram. Make sure electronic connector is not coming into contact with liquids. This may influence measuring results negatively. Remember to remain within the minimum and maximum flow-rate limits as indicated. Avoid any UNCONTROLLED AIR PRESSURE through the flow meter. High bars at the beginning will results in more than 38.000 rotations per second of the rotor, will DESTROY rotor blades. The measurement principle is based on volume measurement; air in water, for example, is counted as a medium. Once the flow meter has been installed in accordance with these directions, a smooth operation is guaranteed.


Technical Specifications

Flow meter - SF800 Data based on water at 20°C (68°F)

Range

Flow velocity*:

0.5 – 20 litre per minute

Temperature:

-20 – +90 °C

Operating pressure:

16 bar

Max. pressure:

40 bar

Technical information SF-800 Process connections:

3/8” hose barb; 3/8”BSP Male

Excitation:

5 to 24 VDC, 12 to 24 mA

Power consumption:

12 – 36 mA/s

Material:

PVDF, Vectra (rotor), Viton or EPDM

Output:

frequency

K-factor:

+/- 6100 pulse/litre

Output frequency:

100 to 2000 Hz (depending on the flow velocity

Length cable:

15 cm standard (different length on request)

Connector electronics:

3-wire flat cable sealed in housing (jack-plug or molex connector on request)

Reliability Interchangeability**:

+/- 2.25 %

Accuracy:

+/- 1.00 %

Reproducibility:

+/- 0.30 %

Medium Medium type: Viscosity:

clear or translucent liquids capable of transmitting infrared light 1-1000 Cst

Examples:

water, chemicals, oil, beer, syrup


DYNAPAR brand brand VEEDER-ROOT Rate Indicators/Controllers

A103 Rate Meter & Totalizer Scaled measurement of rate or speed – plus totals… large display with backlighting

The A103 Rate Meters with Totalizer are extremely compact indicators providing high-visibility readout of virtually any rate: gallons/minute, feet/minute, parts/hour, etc. – plus a total count. Easy to program inputscaling, decimal point, and "dummy-zero" features assure maximum flexibility for any application. The A103 series also includes matching indicators for count totalization, elapsed time indication, simple speed display (RPM) as well as models with a preset output for control by count or time. All are in a uniform 36 x 72 millimeters bezel size package, enhancing your control panel with a family of devices that look and program alike. A supertwist LCD display with thick 12mm (.47") high digits allows for easy viewing at a glance and feature display-backlight capability by simply connecting an external 12VDC supply. Powered by a long-life internal 3 volt battery, the A103 requires no external voltage source to operate. ■ Matching totalizing and preset counters, elapsed time indicators, preset timers, and advanced feature rate indicators look great together on a panel ■ High visibility LCD, 4-digit rate and 8-digit totals display with programmable decimal point and "dummy zero". Backlighting capability standard ■ Dual input scale multipliers for independent engineering unit calibration of rate and total ■ Available with calibrated pulse output (A103-009) ■ Long life 3 Volt lithium battery eliminates the need for external power ■ Option modules provide additional functionality and added convenience – fast, easy installation ■ NEMA 4/IP65 rated front panel for use in washdown environments The A103 indicators are further enhanced by a series of quick-attach option modules. These can provide a power supply for sensors and display backlighting, and accept high or low voltage AC or DC input signals.

Dimensions & Mounting: See dimensions figure. Panel Mount with supplied mounting bracket and gasket Connections: Screw terminals Operating Temperature: +32° to +131 °F (0° to +55°C) Weight: Approximately 64 grams (2.25 ounces)

OPTION MODULE SPECIFICATIONS Option modules accessories provide a convenient integrated solution to applications that require AC or high voltage DC signals, and/or a voltage source for use with the A103's display backlight feature or external. Specifications for each option module feature follow, while specific combinations of features are listed in the "Models" table, below. High Voltage Input: Allows A103 to accept 100 to 260 Volt AC/DC as signal input Low Voltage Input: Allows A103 to accept 15 to 30 VAC or VDC as signal input AC Power Supply: Provides 10 - 20 VDC @ 50mA for display backlighting and/or sensor. Requires connection to 115 or 230 VAC, 50/60 Hz Model No. A103-005 A103-009

Description A103 Rate Meter & Totalizer A103 Rate Meter & Totalizer w/Pulse Output The following option modules attach to the rear of the A103 :

Model No.

AC Power Supply

A103-A12 A103-A17

X

A103-A19 A103-A10

X

A103-A14

X

Low Voltage Input

High Voltage Input

X X X X

Dimensions:

SPECIFICATIONS High Speed Input: PNP or square wave pulse; 10 kHz max (50% duty cycle), 45 µsec min pulse width; Low State: < 1.0 VDC, High State: > 2.0 VDC (28VDC max) Low Speed Input: NPN, Contact Closure; 30 Hz max (50% duty cycle), 12 ms min pulse width; Low State: < 1.0 VDC, High State: > 2.0 VDC (28VDC max) Calibration: Independent programmable input scale multipliers for rate (range: 0.001 to 9999) and totals (range: 0.0001 to 99.9999). Additional calibrator for pulsed output (model A103-009), see below. Pulsed Output: Model A103-009 only. Isolated Photomos relay; 0.1 amp @ 30 VAC/DC, >50Ω on resistance. Independent programmable calibrator scales input pulse rate by multiplier of 0.0000 to 0.9999 Power Source: Single or dual 3V Lithium battery; typical 5 years life w/single battery, 10 years w/dual batteries Display: 12mm high, Supertwist LCD; 4 digits w/selectable decimal point and "dummy zero" 5th digit; "Low Bat" indicator Backlighting: Green Illumination over whole viewable area. Requires 10 to 28 VDC power source

72mm (2.83") 68mm (2.66")

36mm (1.42") 33mm (1.30")

4

5

3

6

2

7

1

8

Option Module Rear View

A103 Rear View Depth Behind Panel Without Adaptor Module: 39mm (1.54") With Adaptor Module: 89mm (3.50") Panel Cutout: 33mm x 68mm(1.30" x 2.66")

DANAHER CONTROLS


Flow meter SF800/6

The patented SF800 technology is the basis for the highgrade fluid flow meters. It makes a constant reliable high-accuracy flow measurement throughout a large flow rate (0,5-20 l/min) possible.

One of the biggest advantages of the SF800 sensors is that because of the resistance-free working-principle (the rotor floats in the medium) the SF-800 fluid flow meters are not subjected to wear. To prevent any leaking, the SF-800 is sealed by ultrasonic sound waves.

On request, an additional protection for the electronics in the form of an added silicone-layer is possible. Because solid particles and/or contaminated medium can damage the sensor or influence the measurements, we advise the use of a filter (20 micron); if necessary these filters can be provided as well.

Working Principle The patented SF800 technology is the basis for these high-graded flow meters. The geometry of the rotor housing (causing a radial flow in) in combination with the light weight Vectra rotor (0,04 grams) makes the rotor float in the medium. Because the rotor floats there is the measurement process is nearly resistance-free, guaranteeing high accuracy, durability and linearity.

An integrated PCB emits an infrared signal, which is interrupted by the three blades of the rotor. SMD components transform the interrupted signal into a pulse. Because of the construction of the rotor housing, the SF800 flow sensors are practically insensible to high pressure.

The materials used (PVDF and Vectra) are to a great extent chemical-resistant and temperaturedurable. Contrary to many other fluid flow measurement systems, the SF800 sensors do not have to be calibrated. The limited number of parts and intelligent design results in product with infinite application possibilities and an excellent priceperformance ratio.

Instructions for installation and use Before putting the flow-meter into operation, please note the following:

1. 2. 3. 4. 5. 6. 7.

8. 9.

10. 11.

Hose discharges may not be subjected to pressure when the flow meter is put into operation. Medium-supply lines must be thoroughly cleaned before use. Use of a 20 (Micron) pre-filter is recommended. Solid particles or contamination in the medium may damage the flow meter and/or influence the measurement results. IMPORTANT: WATCH ARROW ON FLOW METER TO INSTALL IT IN CORRECT FLOW DIRECTION. Once the flow meter has been installed, the system should be filled slowly, to avoid air damaging the rotor. Hook up electronic connector to the flow meter. Make sure that the electrical connections have been hooked up as indicated on this diagram. Make sure electronic connector is not coming into contact with liquids. This may influence measuring results negatively. Remember to remain within the minimum and maximum flow-rate limits as indicated. Avoid any UNCONTROLLED AIR PRESSURE through the flow meter. High bars at the beginning will results in more than 38.000 rotations per second of the rotor, will DESTROY rotor blades. The measurement principle is based on volume measurement; air in water, for example, is counted as a medium. Once the flow meter has been installed in accordance with these directions, a smooth operation is guaranteed.


Technical Specifications

Flow meter - SF800/6 Data based on water at 20°C (68°F)

Range

Flow velocity*:

0.5 – 20 litre per minute

Temperature:

-20 – +90 °C

Operating pressure:

250 bar (static pressure)

Max. pressure:

250 bar

Technical information SF-800/6 Process connections:

3/8”BSP female

Excitation:

5 to 24 VDC, 12 to 24 mA

Power consumption:

12 – 36 mA/s

Material:

PVDF, Vectra (rotor), Viton or EPDM

Output:

frequency

K-factor:

+/- 6100 pulse/litre

Output frequency:

100 to 2000 Hz (depending on the flow velocity

Length cable:

15 cm standard (different length on request)

Connector electronics:

hirschmann connector

Housing:

stainless steel, AISI 303

Reliability Interchangeability**:

+/- 2.25 %

Accuracy:

+/- 1.00 %

Reproducibility:

+/- 0.30 %

Medium Medium type: Viscosity:

clear or translucent liquids capable of transmitting infrared light 1-1000 Cst

Examples:

water, chemicals, oil, beer, syrup


DYNAPAR brand brand VEEDER-ROOT Rate Indicators/Controllers

A103 Rate Meter & Totalizer Scaled measurement of rate or speed – plus totals… large display with backlighting

The A103 Rate Meters with Totalizer are extremely compact indicators providing high-visibility readout of virtually any rate: gallons/minute, feet/minute, parts/hour, etc. – plus a total count. Easy to program inputscaling, decimal point, and "dummy-zero" features assure maximum flexibility for any application. The A103 series also includes matching indicators for count totalization, elapsed time indication, simple speed display (RPM) as well as models with a preset output for control by count or time. All are in a uniform 36 x 72 millimeters bezel size package, enhancing your control panel with a family of devices that look and program alike. A supertwist LCD display with thick 12mm (.47") high digits allows for easy viewing at a glance and feature display-backlight capability by simply connecting an external 12VDC supply. Powered by a long-life internal 3 volt battery, the A103 requires no external voltage source to operate. ■ Matching totalizing and preset counters, elapsed time indicators, preset timers, and advanced feature rate indicators look great together on a panel ■ High visibility LCD, 4-digit rate and 8-digit totals display with programmable decimal point and "dummy zero". Backlighting capability standard ■ Dual input scale multipliers for independent engineering unit calibration of rate and total ■ Available with calibrated pulse output (A103-009) ■ Long life 3 Volt lithium battery eliminates the need for external power ■ Option modules provide additional functionality and added convenience – fast, easy installation ■ NEMA 4/IP65 rated front panel for use in washdown environments The A103 indicators are further enhanced by a series of quick-attach option modules. These can provide a power supply for sensors and display backlighting, and accept high or low voltage AC or DC input signals.

Dimensions & Mounting: See dimensions figure. Panel Mount with supplied mounting bracket and gasket Connections: Screw terminals Operating Temperature: +32° to +131 °F (0° to +55°C) Weight: Approximately 64 grams (2.25 ounces)

OPTION MODULE SPECIFICATIONS Option modules accessories provide a convenient integrated solution to applications that require AC or high voltage DC signals, and/or a voltage source for use with the A103's display backlight feature or external. Specifications for each option module feature follow, while specific combinations of features are listed in the "Models" table, below. High Voltage Input: Allows A103 to accept 100 to 260 Volt AC/DC as signal input Low Voltage Input: Allows A103 to accept 15 to 30 VAC or VDC as signal input AC Power Supply: Provides 10 - 20 VDC @ 50mA for display backlighting and/or sensor. Requires connection to 115 or 230 VAC, 50/60 Hz Model No. A103-005 A103-009

Description A103 Rate Meter & Totalizer A103 Rate Meter & Totalizer w/Pulse Output The following option modules attach to the rear of the A103 :

Model No.

AC Power Supply

A103-A12 A103-A17

X

A103-A19 A103-A10

X

A103-A14

X

Low Voltage Input

High Voltage Input

X X X X

Dimensions:

SPECIFICATIONS High Speed Input: PNP or square wave pulse; 10 kHz max (50% duty cycle), 45 µsec min pulse width; Low State: < 1.0 VDC, High State: > 2.0 VDC (28VDC max) Low Speed Input: NPN, Contact Closure; 30 Hz max (50% duty cycle), 12 ms min pulse width; Low State: < 1.0 VDC, High State: > 2.0 VDC (28VDC max) Calibration: Independent programmable input scale multipliers for rate (range: 0.001 to 9999) and totals (range: 0.0001 to 99.9999). Additional calibrator for pulsed output (model A103-009), see below. Pulsed Output: Model A103-009 only. Isolated Photomos relay; 0.1 amp @ 30 VAC/DC, >50Ω on resistance. Independent programmable calibrator scales input pulse rate by multiplier of 0.0000 to 0.9999 Power Source: Single or dual 3V Lithium battery; typical 5 years life w/single battery, 10 years w/dual batteries Display: 12mm high, Supertwist LCD; 4 digits w/selectable decimal point and "dummy zero" 5th digit; "Low Bat" indicator Backlighting: Green Illumination over whole viewable area. Requires 10 to 28 VDC power source

72mm (2.83") 68mm (2.66")

36mm (1.42") 33mm (1.30")

4

5

3

6

2

7

1

8

Option Module Rear View

A103 Rear View Depth Behind Panel Without Adaptor Module: 39mm (1.54") With Adaptor Module: 89mm (3.50") Panel Cutout: 33mm x 68mm(1.30" x 2.66")

DANAHER CONTROLS


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.