Introduction to DASK Crestal Approach Tool DASK1 XRT352035

The distance from alveolar crest to sinus floor should be measured radiographically prior to surgery. The site is prepared with twist drills in sequence to within 1mm short of the sinus floor. "DASK 1" is introduced into the osteotomy and the cortical bone of the sinus floor is carefully removed using light apical pressure. As the “DASK1 “goes through the bone it is possible to feel the drill give. The “DASK 1 “is then removed without any further preparation. It is also possible to partially prepare the cortical bone with the DASK 1 and then up-fracture using a matched osteotome.

(800~1200rpm) The saline from internal irrigation not only cools but it also holds the sinus membrane away from the “Dask 1” thus decreasing the risk of perforation

DASK2 XED331035

CONTENTS

Once the sinus cavity has been accessed, the "DASK 2" is introduced and a much broader detachment from the sinus floor is facilitated horizontally by hydraulic pressure. The "DASK 2" can also be used for a lateral approach.

(800~1200rpm) The "DASK 2" instrument is internally irrigated with a T shaped end which creates lateral hydraulic pressure during irrigation and this is used to raise the sinus lining

Introduction to DASK

Lateral Approach Tool Crestal Approach

DASK3,4 XRT064025

To make a lateral window using the "DASK 3,4"

XRT084025

(800~1200rpm) * Provided excessive pressure is avoided, perforation of the sinus lining is unlikely, even if the "DASK 3,4" contacts the sinus membrane.

Lateral Approach

DASK5 OSTEON Sinus&Lifting TM

XST083025

To make a lateral window using the "DASK 5". removing a the bone core which can then be used to close the lateral window.

(800~1200rpm) * By using a “ DASK 5” without care it is possible to tear the sinus membrane. The recommended technique is to remove bone slowly using pressure on one side of the drill at a time , gently rocking the drill then removing and checking. As soon as the lining shows through move the pressure to another part of the circumference to avoid perforating the lining. Once the sinus lining shows through in a full circle the core can be elevated *Washing method: Remove contaminants by placing the drill in Sodium Hypochlorite (5% NaClO solution) for 15~20 minutes, then rinse with flowing water before washing with an ultrasonic cleaner (50~60 Hz) filled with distilled water for 10 minutes.


Crestal Approach (Sinus Lifting)

Clinical Case

Grind-Out Technique

Preoperative panoramic view

After Ø3.8 Final drilling, eliminate the resid-

Lift the sinus membrane gently using the

Further laterally detach the sinus membrane

ual bone (1mm) by using the DASK1.

dome-shaped sinus curette

by using water pressure from the DASK 2.

Condense the bone graft material

Implant placed (SuperLine)

Postoperative panoramic view

Site preparation with twist drills to the resistance of the cortical bone of the sinus floor

(in hard bone)

Squeeze the bone graft material (OSTEONTM Lifting) into the sinus cavity

When the sinus floor “gives” , then use the dome-shaped sinus curette

When a "sunken"sensation met, change into the dome-shape sinus curette

Osteotome Technique

Sinus membrane felt and detached Osteotome of final or penultimate size (in soft bone)

Greenstick fracture

Lift the sinus membrane gently using the dome-shaped sinus curette

OSTEON™Lifting introduced

Graft material condensed

Implant placed (SuperLine)

GBR to achieve verticohorizontal augmentation


Lateral Approach (Sinus Elevation) Grind-out technique

Tilt the DASK3,4 at 45 degree against bone wall, and drill with a pivoting action to create a circular hole.

If the lateral wall needs to be a expanded, Grind and move wit DASK 3,4 simultaneously as shown above.

Wall-off technique

â– Thin wall

In case of thin wall, grind up to only bottom line(1.5mm) on DASK 5 carefully in order not to perforate membrane on the other side.

â– Thick wall

Grind the lateral wall with pivoting action until the sinus membrane shows through on the other side. After detaching a bony island which was made by using DASK 5, keep it separate for covering over the hole after bone grafting.

In case of thick wall, you can grind up to upper line(3.0mm) on DASK 5 carefully in order not to perforate membrane on the other side.

Detach Sinus membrane using the dome-shape sinus curette.

Elevate the sinus membrane to create adequate space for the graft material

Fill the bone graft material (OSTEONTM Sinus) into the sinus cavity

Implant placed (SuperLine)

Detach the sinus membrane create space for the graft by using the water pressure of the "DASK2"


Clinical Case

DASK (Dentium Advanced Sinus Kit)

Clinical Case 1 : Grind-out technique DASK • Simple & easy access to sinus cavity • Little risk of membrane perforation • Broad exposure of bony walls with special tools

Preoperative panoramic view

Postoperative panoramic view

Lateral window prepared with DASK3,4.

Sinus Tool | Scale 1 : 1.2 / mm Type

Art. No.

XRT064025

Ø6.0

XRT 064025 Lateral Approach

4.0

XRT 084025 XST 083025

XRT084025

Ø8.0

XRT 352035

Crestal Approach

XED 331035 XST083025

Lateral wall of the maxilla exposed prepared and the schneiderian membrane reflected

Implant (Superline 5010SW) picked up for installation

Ø6.6

Bone graft material (Osteon Sinus) placed into the sinus cavity and around the periimplant defect

Ø8.0

1.5 1.5

XRT352035

Ø3.5 12 10 8

6

4

2

0

12 10 8

6

4

210

Clinical Case 2 : Wall-off technique XED331035

Ø1.6

Stopper | Scale 1 : 1 / mm

Preoperative panoramic view

Dome-shape sinus curette introduced to take off the seal around the window

Postoperative panoramic view

Osteoconductive graft material(OSTEONTMSinus) introduced

Bony window prepared with DASK5.

The bony island repositioned

Drilling Depth

L

Art. No.

08

10.6

XFDST 08

06

12.6

XFDST 06

04

14.6

XFDST 04

02

16.6

XFDST 02

Ø5.14

Ø5.14 10.6

Ø5.14

12.6

Ø5.14

14.6

16.6

XFDST08 XFDST06 XFDST04

XFDST02

Ø3.3


DASK (Dentium Advanced Sinus Kit)

OSTEONTM Sinus & Lifting

Sinus Elevation Instruments | Scale 1 : 0.6 / mm

OSTEONTMSinus Easy & Simple Bone Graft

XSE1L

GBR, Sinus Bone Substitute Material XSE2L

XSE3L DASK XSE4L

Product

Osteotome Kit

REF GBG 0510S

Particle Size 0.5~1.0mm

TM

OSTEON Sinus

0.5cc / 1.0cc GBG 1020S

Osteotome Kit

Volume

1.0~2.0mm

Osteotome compresses the bone laterally, providing denser bony interface rather than removing valuable bone from the surgical site.

OSTEONTMLifting

Osteotomes | Final drill type / Scale 1 : 0.5 / mm

Simple & Fast Bone Graft

XOF 20 A1

The 0.3~0.5mm particle size of OSTEONTM prevents the performation of sinus membrane

ØB ØA

XOF 34 A1

XOF 38 A1 XOFK XOF 43 A1

XOF 48 A1

Art. No.

ØA

ØB

XOF 20 A1

Ø1.7

Ø2.8

XOF 34 A1

Ø2.3

Ø2.8

XOF 38 A1

Ø2.7

Ø3.2

XOF 43 A1

Ø2.8

Ø3.8

XOF 48 A1

Ø3.0

Ø4.3

Product

REF GBG 0305S

Particle Size

Volume

0.3~0.5mm

TM

OSTEON Lifting

0.25cc GBG 0510S

0.5~1.0mm


DASK_manual