97-400-3

Page 35

Technical data Pleated polyester 4292 8.4 m2 > 99.9 %

Main Filter, optional Type Part No Total filter surface Degree of separation EN 60335-2-69 part 1

PTFE coated pleated 429203 5.0 m2 > 99.9 %

HEPA filter (optional 2nd filter ) Part No Total filter surface Degree of separation EN 1822-1 HEPA H13 Max temp filter

99.95% 80 oC

Air pulse filter cleaning Air consumption Hose connection Electric connection

4 l/s, 4 bar 6 mm 24 VDC, 19A

42136 5.2 m2

Installation 1

7. Holes for fitting the unit to the ground (where existing)

6

The unit can be mounted on concrete surface/floor of suitable thickness.

2 5 3

The electrical connection should be connected to adequate starting equipment. A certified electrician should make the installation. 5 pin Euro connection is available as an alternative. The equipment is prepared to draw 3-phase electric feed and low volt cabling into its enclosure.

4 Electric cables should be mounted to make it possible to raise the unit 200 mm for potential bearing changes; without that the electrical connection would need to be disconnected.

7 Connection points 1. Compressed air feed 4 l/s, 4 bar (for use with automatic filter cleaning). 2. Electric feed (for use with integrated control box). 3. Connection point for micro switch circuit(where existing). 4. Connection of motor tension from a separate control box (in some cases). 5. Inlet to cyclone (can be rotated for preferred direction). 6. Exhaust

A separate, lockable disconnect must be installed where it is readily accessible to the pump. Connect the pipe work to the inlet and possible to the outlet. Never start the pump without the correct cables and hoses being connected. If the outlet is directed up it should be connected with an exhaust diff user, a bend or a flap so rainwater and objects do not fall into the outlet. Exhaust air can be between 100-150o C. Put the plastic bag under the cyclone or connect the container.

DC 11-Module - 35

Part No 94153-C

ENGLISH

Main Filter, standard Type Part No Total filter surface Degree of separation EN 60335-2-69 part 1


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.