Issuu on Google+

Heat Exchanger Models for 2011


4 Models Available We have 4 Models available that can be fitted to any shed. The Clima Unit has a range of application possibilities. Call us to arrange to see the options Model

Bird Numbers

Air Flow Capacity

2.5 M

63,000

22,300

2M

52,000

18,400

1.5 M

39,000

13,700

2 INTO 1

UP TO 50,000 Max 25,000 per shed

22,000

All models are 9 metres long

Aids compliance with environmental permitting Meet your carbon reduction commitment targets! Reduce your dust, ammonia and odour


2.5m unit with external pipe

2m unit with external pipe

1.5m unit with internal pipe

New for 2011 2 into 1 unit with internal pipe


“The Perfect Chick Start Every Time”

2 Warm Poultry Houses using 1 Heat Exchanger = Bigger Savings With the Same Great Performance! Saving Over 50% Energy, & Creating a Better Growing Environment Maximum Of 25,000 Birds In Either Shed. Each Shed Can Have Different Numbers


Proven UK Performance 52.9% gas savings on 35 UK sheds of all ages Extra weight gain average 23.9 gm Less podo down 12.3% Less hockburn down 5% Less factory rejects down 0.3% Mortality down 0.125% Dry litter - up to 85% less top up needed Reduction in total CO2 of 40% Works in any conditions – minus 30OC – the Russians are our biggest customers! Pleasant working environment with easier flock management providing all of the automatic minimum ventilation for at least the first 2 weeks.


What We Do We are dedicated to providing the poultry industry with AFFORDABLE environmental solutions. We provide a range of heat exchangers and have sold over 100 Units in the UK Saving over 1000 tonnes of carbon Independent trials by 3 UK poultry producers have PROVEN the performance of the Clima Unit.


Proven Benefits GOOD FOR THE ENVIRONMENT Reduced Energy Use 50% Less Heating Less Litter Less Dust Less Odour

GOOD FOR YOUR POCKET! Halve Your Heating Costs FCR Improved Less Rejects Less Bales Of Top Up Litter

GOOD FOR BIRD WELFARE Less Hockmarking Lower Mortality Healthier Birds Less Antibiotics Used Low Co2

GOOD FOR THE FARMER Better Working Environment Less Top Up


Unique Ventilation Internal spiral tubing connected to our unique ‘T’ piece with recirculation fans A unique robust tubing

Winches out of the way

Easily retracts for access and cleaning


We Get: No Cold Spots An Even Warm Environment Dry Litter Even Chick Spread

1.5m unit with internal pipe Reduce your heating costs Improve your house climate Improve your litter quality


How It Works By passing the hot exhaust gas from the shed over our Clima Unit2 tubing, the cold incoming air, inside the tubes, is preheated, and fuel consumption to heat the shed is proven to be REDUCED by typically 52.9%. 4. Air warmed by the Clima Unit enters the shed

5. Exhaust air leaves with less odour carrying

O

25 C Fresh Clean Air Is Filtered, Warmed, & Enters The Shed

3. HEAT EXCHANGE Occurs NO AIR MIX-

1. Hot air from the shed enters the Clima Unit

2. Clean fresh air is filtered and enters the

Let the air work for you


The Clima Unit2 saves 80% of the energy in the hot air that normally is discharged straight into the atmosphere by standard minimum ventilation. Money Back Guarantee We are so confident of the performance of the Clima Unit2 if you buy one and you are not satisfied with the performance at any time in the first 12 months, we will take it away for free, and refund your money in full! Mainland UK

Lid opened Showing the heat exchange tubing and wash system


01.03.2011 – 30.06.2011

Price List

To Buy 2.5

metre Clima Unit for up to 63,000 broilers

£34,750 + vat

2.0

metre Clima Unit for up to 52,000 broilers

£33,750 + vat

1.5

metre Clima Unit for up to 39,000 broilers

£31,750 + vat

a modified Clima Unit to 2 into 1 supply two sheds for up £46,850 + vat to 50,000 broilers Includes delivery, fitting, wiring, & free consultancy (details below)

Money Back Guarantee We are so confident of the performance of the clima unit2 if you buy one and you are not satisfied with the performance at any time in the first 12 months, we will take it away for free, and refund your money in full! Mainland UK only. The bird numbers are based on rearing the broiler chick to 14 days, during normal conditions without using any other ventilation other than the Clima Unit. However by upgrading to a larger unit with extra ventilation capacity it will be possible to take the birds to later in the crop, with extra benefits to bird performance and energy saving. Purchase price includes standard installation costs, site assessment, shipping to site, external pipe work connections, internal spiral pipe, electrical wiring, and commissioning, with a one year parts and labour warranty. The only cost for the customer is base preparation, drainage compliant for existing regulations, for the condensate and wash water, and water supply at sufficient pressure as needed. If the customer requests an external roof pipe it will cost an extra £1,340 fully installed. In exceptional circumstances there may be an extra installation cost to the customer, if normal machinery cannot access the site, to unload the unit. This would be discussed fully with the customer before the order is placed, and after a site inspection the only regular expense will be filter renewals, approx £100 p.a. Any damage caused by the customer or a third party, is the responsibility of the customer. Each farmer must apply for a variation to permit from the environment agency to register the heat exchanger


The Affordable Environmental Solution

We can go almost anywhere!

INCLUDED IN PRICE: Delivery – There May Be A Charge For Exceptional Circumstances Installation Wiring Commissioning WE ALSO PROVIDE: Free Training Free Ongoing Consultation – As Many Free Visits Or Phone Calls As You Need.

Free Environmental Reports – Showing All The Environmental Benefits You Have Made By Buying A Clima Unit.

Lease Purchase Finance Mike Robinson of Limestone Asset Finance 07791 555431 Simon Johnson of Country and Commercial Finance 07720 548797 •

Vencomatic does not receive any benefit or commission for recommending these companies.


Independent Research House 1 With Clima Unit Crop Date Gas no. 1 2 3 4 5 6 7 8 9 10 11 12 13

19/08/2008 14/10/2008 10/12/2008 04/02/2009 31/03/2009 26/05/2009 22/07/2009 18/09/2009 13/11/2009 11/01/2010 09/03/2010 04/05/2010 29/06/2010 Average

450 936 1449 1300 1390 680 640 458 993 1421 905 575 407 893

Pullets Cockrels Food % growth % growth 102.2 97.35 127852 104.4 101.72 129467 103.3 97.85 136424 100 99.19 124240 107.33 136624 99.77 103.38 121925 97.8 98.15 134553 95.18 96.97 139891 101.65 100.21 145466 102.2 100.16 132990 107.14 107.64 134120 99.68 102.03 132793 98.35 108.15 128358 100.973 101.548 132669

Pay back less than 3 years! 2 identical sheds, with chicks from same breeder site. 1.5m Clima Unit installed May 2008. Trials conducted independently of Vencomatic Sept 08-June 2010

Clima Unit Heat Exchanger Research Finance: Made ÂŁ1650/crop. 6.2 crops/year. Made ÂŁ10,230/year. The Average 1.9kg bird would leave the farm 23.9gm heavier. If FCR 1.7 it will consume 6gm of more food to gain the extra weight Therefore the net improved growth of 1.26% for .19% extra food =1.05% if FCR 1.7. This equates to .018 improvement to FCR


Independent Research House 2 Without Clima Unit Crop no.

Date

Gas

Pullets Cockrels % growth % growth

Food

0805/77

19/08/2008

942

97.8

99.84

126248

0806/78

14/10/2008

1748

104.95

99.53

125160

0807/79

10/12/2008

3164

101.65

98.74

132641

0901/80

03/02/2009

2370

101.79

100.16

131090

0902/81

31/03/2009

2163

102.03

134980

0903/82

25/05/2009

1205

100

99.84

125631

0904/83

21/07/2009

1088

94.94

92.67

127720

0905/84

18/09/2009

1013

92.86

93.45

136545

0906/85

13/11/2009

2051

102.25

104.26

148660

1001/86

08/01/2010

3071

104.4

100.21

141772

1002/87

09/03/2010

1917

102.2

102.65

132946

1003/88

04/05/2010

1165

101.65

100.16

130475

1004/89

29/06/2010 Average

997 1761

101.1 100.466

100.54 99.5446

127487 132412

Gas saving 49.29% Ave % growth House 1 101.261 House 2 100.005 Difference

Feed consumed House 1 132669 House 2 132412 Difference 257 Difference % 0.19%

1.26% Lincs results 22gm

10 crops

Norfolk Starston 24 gm 8 crops


Independent Research There are significant savings, all year round, even in summer months, the % saving will always be similar, regardless of the time of year. The older and less energy efficient your sheds, the more you spend on fuel, the more the Clima unit2 can save you! Look what the press has to say about the Clima Unit. Call us to arrange a visit to a farm where you can find out exactly how the Clima Unit can benefit you.


Hot of the Press


For any further information or to request a farm visit and presentation please contact: Wayne Olbison, Sales and technical director 07966 498 487 Brian Moxon, Northern sales manager 07854 101 776 Gary Allen, Southern sales manager 07528 669 037 Vencomatic UK, Avian House, Thirsk Industrial Park, Thirsk, North Yorkshire, YO7 3BX.

Free Phone 0800 2315 316 | Email info@climaunit.co.uk See the video on our website or You Tube


Clima Unit Heat Exchanger Brochure 2011