G48 Series PRESET COUNTER

DIN 48 X 48 COMPACT SIZE ELECTRONIC PRESET EASY EDITING ( INDIVIDUAL DIGIT KEYS ) LCD DISPLAY WITH LED BACKLIGHT PRESCALE KEY LOCK FREE WRITE


MODELS Digit

Model

Power source

Preset

G48−305

AC100~240V

1 level preset

DC12~24V

G48−306 6 G48−315

2 level preset

G48−325

1 level preset + prewarn

AC100~240V

Input

Body length

Contact / Open collector Voltage input can be selected by programming

Standard size Short size Standard size

FRONT PANEL FEATURES 1 Count display 4 Output indicator 2 Editing display 5 External reset input indicator 3 Program item display 6 External key lock indicator count speed 7 Individual digit setting keys IN Hz input programming 8 Reset key IN output programming 9 Mode key OUT output time selection 10 Display key OUT ms prescale PS selection of decimal point position DP write W selection of reset time RST ms key lock protection KEY/P preset value indication SET prewarn setting PW

6

5

4

KEY/P RST

OUT 1 2 PW

1 KEY/P RST PW PS D P W S E T IN OUT 12

3

6

5

2 3

ms

Hz

4

3

2

1

7 RESET

8

MODE

DISP

9

10

< 6 digit >

SETTING VALUES Count Speed Input Mode Count Mode

30Hz, 1000Hz, or 5000Hz can be selected by pressing key 1. Contact / Open collector or voltage input can be selected beforehand. One of the following 5 count modes can be selected:

ADD INPUT

0

( 6 Digit )

999999

Input A: count input

Input A Input B

Input B: count prohibit

Write in value is 0

ADD SUBTRACT INPUT

( 6 Digit ) − 9 9 9 9 9 Input A

H

0

L

L H

Input B

L

H L

5 4

3

3

SUBTRACT INPUT

Count value

Count value

0

0

Input A: count input

Input A Input B

2 1

1

0

QUADRATURE INPUT

−99999

Input B: count prohibit

H

Write in value is 10

( 6 Digit ) − 9 9 9 9 9 Input A

0

999999

H L

L H

Input B

H L

L 10

Count value

2

1

The example shown is open collector input.

( 6 Digit ) Write in value

Subtracts from write-in value and outputs at preset value

3

2

2 1

The example shown is open collector input.

999999

H

3 9

2

8 6 5

( 6 Digit ) − 9 9 9 9 9 Input A

3

2

2

1

0

The example shown is open collector input.

DIRECTION INPUT

3 2

1

Count value

7

0

999999

H L

Input B

H L 3 2

The example shown is open collector input.

OUTPUT MODE Standard Output Equal output Lower limit output Upper limit output Upper - lower limit output Upper 1 - Upper 2 limit output

Count value

1

3 2

2 1

0

The example shown is open collector input.

One of the following 6 output modes can be selected. Output times can in either case be one shot or hold (1st level output in 2 level preset model is either Hold1 or Hold2). Output occurs only when and continues as long as the current count value is equal to the preset value. Lower limit comparator output. Comparator outputs are the most suitable for positioning application. 1 level preset output is lower limit comparator output. Upper limit comparator output. Comparator outputs are the most suitable for positioning application. 1 level preset output is lower limit comparator output. Upper - Lower limit comparator output. Comparator outputs are the most suitable for positioning application. In 2 level preset model, the 1st preset value is lower comparator out, while 2nd preset value is upper comparator out. Upper 1 - Upper 2 limit comparator output. In 2 level preset model, the 1st and 2nd preset values are upper limit comparator outputs.


BASIC OPERATION The G48 has 2 operation modes. While initial setting such as selection of input and count methods is done in the Program Mode, usual counting and presetting are done in the Run Mode. Use the MODE key to enter the Program Mode and the DISP key to return to the Run Mode. RUN MODE count value

1 LEVEL PRESET TYPE

preset value

DISP

count value

2 LEVEL PRESET TYPE

1st level preset value

1 LEVEL PRESET + PREWARN TYPE

preset value

count value 2nd level preset value

DISP

count value

count value prewarn value

MODE

DISP PROGRAM MODE

count speed

input mode

count method

output mode

key protect

output time

reset time

reset mode selection of decimal point position

write

prescale

SETTING VALUES Output time

In case of standard output, preset can either be one shot (pulsed) or latched (hold, hold 1, hold 2). Latched outputs can be programmed as follows:

Hold

Latched until a reset signal is sent.

Hold 1

Latched until output 2 goes away.

Hold 2

Latched until a reset signal is sent; independent from output 2.

One Shot Reset Mode

ms

Setting range in 10ms steps is possible.

1 level preset output (OUT), 2nd level preset output (OUT2) of 2 level model, preset output (OUT) of 1 level preset+prewarn model.

1st level preset output (OUT1) of 2 preset level model, prewarn output (PW) of 1 level preset + prewarn model. Applicable to OUT, PW, OUT1 or OUT2

One of the following 7 reset modes can be selected. Except for standard output, Mode A is only available for other output modes. The outputs below refer to 1 level preset models, to the 2nd output of 2 level preset model, and main output of 1 level prest+prewarn model.

Mode A

counts during output.

Mode B

does not count during output.

Mode C

does not count after output.

Mode D

resets at rising edge of output.

Mode E

resets at falling edge of output.

Mode F Mode G

resets at rising edge of output, display "freeze" during output. resets at falling edge of output, display "freeze:" during ouput.

Overrun (without auto-reset)

resettable only for one shot output time resettable only for one shot output time resettable only for one shot output time

Auto-reset

Prescale

Incoming pulses can be prescaled to display the desired measuring unit. The prescale can be set at any value within the range of 0.001 ~ 99.999 Ex.) To display 1 count per 10 pulses, PS value = 0.1.

Decimal Point Position

Decimal point position can be selected out of the following settings: no decimal point, 0.0, 0.00, 0.000

Free Writing

Any desired value can be written on the display. The counter will add to or subtract from the written value. When resetting is made, count value will be replaced with the written value.

Reset Time

Reset time sets minimum pulse time of remote reset signal. Reset time can be set to either 2ms or 20ms.

Key Protect

There are 4 protection levels.

Level 1

Lock program

Level 2

Lock program & front key reset

Level 3

Lock program & preset

Level 4

Lock program, front key reset & preset

Protection level can be selected in the Program Mode.


SPECIFICATIONS MODEL

G48-305

G48-306

G48-315

G48-325

LCD display with backlight ; Digit Size : 10mm × 5mm

DISPLAY NO. OF DIGITS

6

NO. OF DIGIT SETTING KEYS

6

PRESET LEVEL

1

1 preset + prewarn

2

SETTING RANGE

-99999 ~ 999999

PREWARN FEATURE

0~999999

INPUT MODE

Either contact / open collector or voltage input can be selected, depending on programming

INPUT SIGNAL

Open collector, Sink current 10mA (DC power model: power supply volt / 1.2KΩ) L : 0 ~ 5V Voltage (Input impedance 7KΩ) L : 0 ~ 4V H: 6 ~ 30V, Available to duplex wire DC sensor.

COUNT SPEED

30Hz, 1kHz, 5kHz (selectable)

COUNT MODE

Add, Subtract, Add/Subtract (Add/Subtract individual input, Add/Subtract direction, 90° quadrature input)

COUNT RANGE

-99999 ~ 999999 Incoming pulses in either add or subtract mode can be inhibited at input B only.

INPUT INHIBITION PRESCALE

0.001 ~ 99.999

DECIMAL POINT POSITION

( 0 setting is not available )

0.0, 0.00, 0.000, No decimal point

WRITE

-99999 ~ 999999

RESET

Front panel reset, Remote reset, Auto-reset 2msec or 20msec

REMOTE RESET TIME

( selectable )

Modes A, B, C, D, E, F, G can be selected. Except for standard output, Mode A only is available for other output modes.

RESET MODE

2

MEMORY

E PROM

( 10 years, can be used 10000 times )

OUTPUT

Relay output ( 1a ) : load of 250VAC 5A / 30VDC 5A maximum

OUTPUT DELAY

Relay output ( 30Hz : 20msec. 1000Hz : 7msec. 5000Hz : 7msec. ) 1 level preset (standard, equal, lower limit, upper limit) 2 level preset (standard, equal, upper-lower, upper-upper limit) 1 level preset + prewarn (standard, equal)

TYPE OF OUTPUT

Standard output : one shot ( 10 ~ 9990msec ) or HOLD or HOLD 1 or HOLD 2 Equal, Upper, Lower output : Latched only when requirements are full

OUTPUT TIME

Key operation can be disabled at 4 protection levels (L1, L2, L3, L4) by selecting in Program Mode and shorting key lock terminals.

KEY LOCK ERROR DISPLAY

In Add/subtract mode, error message will be displayed on the LCD if the count range is exceeded (overflow error :

POWER SUPPLY

AC100~240V -15%, +10%

SENSOR POWER SOURCE

DC12V 100mA

DC12~24V -15%, +10%

underflow error :

)

AC100~240V -15%, +10% DC12V 100mA

Approximately 7VA for 240VAC, approximately 1.2W for 24VDC

POWER CONSUMPTION OPERATING TEMPERATURE

-10°C~50°C (non-freezing, non-condensing)

FRONT PANEL

IP54

WEIGHT

45~85%RH (non-freezing, non-condensing) standards

Approximately 170g ( AC models ) ; 110g ( DC model )

DIMENSIONS

48 48

6.2

99.8

Clip

Short Body Version (DC model)

44.5

Standard Size (AC Models)

44.5

Front Panel (common to AC and DC models)

6.2

The dimension of the clip is 47.5 × 60.5mm. Install the clip into the rear of counter, push forward and clamp into place while holding the counter firmly against the panel from the front.

63.8

Panel Cut Size : 45 +00.6 × 45 +00.6

Specifications are subject to change without prior notice.