Issuu on Google+

High Performance Air Conditioning

SR series Residen t i a l A i r C o n d i t i o n e r s


Wall Mounted type

SRK

COP 5.71 ( in theSRK20ZIX-S cooling operation )

3D AUTO

Programmed air distribution

Sophisticated design

Quiet operation

Industry leading energy effi from our advanced technol

ZIX series


ficiency and reliability logy. Floor Standing type

SRF COP 4.80 ( in theSRF25ZIX-S cooling operation )

Auto air outlet selection lower and upper outlets

Sophisticated design

Quiet operation


High Efficiency The industry’s highest EER COP levels The ZIX, ZG and ZE series clear the 2010 MEPS.

EER in Cooling

COP in Heating

5.71 5.20

5.5 5.0 4.5

4.14

4.0

5.5

3.33

5.26

5.0

3.42

3.23

3.33 4.48

4.5

2.93

3.85

3.5

5.56

4.44

4.07

4.0

3.82

3.62

2.93

3.5

3.21

3.0

3.0

2.5

2.5

SRK20ZIX-S SRK25ZIX-S SRK35ZIX-S SRK50ZIX-S SRK60ZIX-S SRK63ZE-S1 SRK71ZE-S1

SRK20ZIX-S SRK25ZIX-S SRK35ZIX-S SRK50ZIX-S SRK60ZIX-S SRK63ZE-S1 SRK71ZE-S1

DC PAM inverter An inverter system has a number of advantages over a constant speed system. Its variable speed compressor outputs can ensure quick cooling or heating after start up and attains a set temperature more quickly. The air conditioner can slow down the compressor speed to save energy whilst keeping comfortable conditions. The compressor is DC motor driven so it provides higher performance.

Time

DC PAM INVERTER

DC PowerActiveModule PAM INVERTER

Room Temp.

PAM

PWM

Set Temp. Even Temperature

DC PAM INVERTER

Rated Capacity ON

Compressor (rps)

Utmost comfort and energy efficiency achieved with large output power and control optimisation

DC compressor motor

Time

CONVENTIONAL INVERTER

Motor Efficiency(%)

Magnet Motor

Room Temp.

Improving

Set Temp.

Improving CONVENTIONAL

Induction Motor

Low

Revolution speed

High

ON

Rated Capacity OFF

Compressor (rps)

Less advanced technology does not address the ON/OFF cycle issue.

New Inverter Control (Vector control) New Inverter Control has applied the new advanced technology of Vector control enabling:• Smooth operation from low to high speed • Smooth Sine Voltage Wave form is achieved • Energy efficiency has improved in low speed range

4

OFF


High Efficiency Our Latest Technologies

New propeller fan

Silicon-coated PCB

The new propeller fan was carefully matched with a fan motor in order to keep the same capacity as that of previous models with less electrical consumption. In synergy with the leaf shape grill has seen an improvement of energy efficiency by 5% and a decrease of sound level.(SRC50/60ZIX-S)

The printed circuit board of the outdoor unit is coated by silicon. The coating ensures longevity of the board in humid conditions.

Energy saving leaf shape grill The leaf shape grill was developed in order to maximize natural air flow sent by the propeller fan along the grill. The airflow is very smooth with minimum air resistance. This has lead to a decreased fan motor load and improvement of energy efficiency.

High efficiency scroll compressor. Low vibration and low sound revel By using a scroll compressor there has been an improvement of energy efficiency. Lower vibration and lower sound level have been achieved. Further improvement to efficiency was realized by use of a neodymium magnet applied in the compressor motor. (SRC50/60ZIX-S)

ZAM steel sheet ZAM steel sheet is used on the base of the outdoor units. ZAM has superior corrosion resistance and scratch resistance properties compared to conventional materials. 1) ZAM is a registered trademark of Nissin Steel Co., Ltd. 2) ZAM is a coined name applied to hotdipped zinc-aluminum-magnesium-alloycoated steel sheet developed by Nissin Steel Co., Ltd.

photo is composite image

Indoor unit

Outdoor unit

A combination of fin configuration and copper tube has enabled maximum air flow whille keeping the same size width of the indoor unit. Efficiency rate of heat exchanger has been drastically improved by 30% compared with previous models. The new fin design allows maximum air flow and saving energy simultaneously.

Redesigned by changing the fin configuration from flat sheet to new M shape fin, efficiency has been improved by 10%. An optimum balance of heat transfer and air flow has been achieved.

R e s i d e n t i a l A i r C o nditioners

5


Airflow 3D AUTO Vertical + Horizontal AIR SCROLL 3 motors make 3 independent controls

Programmed air distribution Applied models

3D AUTO

3D AUTO is a one touch programme. Three motors (one vertical working motor + two horizontal working motors) make three independent air flow controls. The airflow is uniform, quiet and reaches at long distance from the indoor unit.

Programmed 3D AUTO Hi-Power (Quick)

Cool Shower

1

SRK-ZIX, SRK-ZG, SKM-ZG SRK63/71/80ZE, Manual Setting only

Manual Setting Floor Heating Vertical Swing

Swing

Wide Swing (Every Corner) Swing

2

Horizontal Air Scroll 8 Direction Swing

Center (Long)

3

Swing

3

4

8

7

6

5

Cool Shower Floor

Automatic control of air flow volume and air flow direction enables comfortable air conditioning of the entire room. In cooling operation, cooled air flows directly to the ceiling not directly onto the occupants of the room. The comfort cooled air flow comes down from the ceiling like a soft shower. In heating operation, warm air flows to the floor directly and spreads along the floor. The concentration of the warm air at floor level increases comfort. 6

2

Swing

Wide-Air (Equal)

4

1

Swing

Spot

Wide

Individual control of right and left louver enables air flow direction from the right and the left side of the unit, setting the most preferable air flow direction and determining whether direct air flow is required or not. At the same time, this minimises energy loss.


Airflow

Applied models All SRK, SKM

Aircraft technology was used in the design of the air conditioner’s airflow system

Jet Air Scroll Long Reach & Silent Air Flow We used the same aerodynamic analysis technology as used in developing jet engines. CFD (computational fluid dynamics) is used for blade shape design and air channels for jet engines. The same technology has been used in our air conditioners. The airflow of the jets created in this system enables a large volume of air to be blown with a minimum amount of power consumption. The airflow is uniform, quiet and reaches a long distance from the indoor unit. Fast

Slow

Colors in the figure show the air speed.

Applied models SRK50/60ZIX, SRK63/71/80ZE

Long Reach Air Flow The jet technology enables powerful airflow ideal for large living areas and commercial premises, increasing your comfort.

SRK50/60ZIX

15m

Applied models SRK-ZIX, SRK-ZG, SKM-ZG

Applied models SRK-ZIX

SRK63/71/80ZE

(in cooling operation)

(in cooling operation)

17m

powerful

Positioning of Installation You can set the left-right air flow directions when you install the air conditioner near the side wall by remote controller operation.

New louver The new louver has a new design and shape.It has increased in surface area by 80%. In addition to improved control of the increased air flow volume, it has improved controllability of the right to left swing function.

80% increased

previous

New R e s i d e n t i a l A i r C o nditioners

7


Clean Air

Generates the same amount of negative ions as a forest environment

Applied models All SRK, SKM

24-hour ION The air conditioner body has a tourmaline coated sheet. Negative ions (2,500 -3,000/cc) are generated even when the air conditioner is not running, allowing you to experience them without incurring any electrical cost.

Keeping the indoor unit clean

Applied models All SRK, SKM

Self Clean operation The ‘self clean operation’ is operated for 2 hours after the unit has ceased normal operation. The indoor fan continues to operate on ultra low speed to dry the unit. This restricts the growth of mould. This feature can be selected on the remote control.

Stop run Normal operation

Situation of mold after one week 2hrs Clean operation

When you don’t execute “Self Clean Operation” Fungal mycelia expand.

Fungal mycelia

When you execute “Self Clean Operation” The spore of mold doesn't germinate.

Spore of mold

Shuts off automatically

The air in your room is kept fresh

Allergen Clear system Push ALLERGEN Mode

Catching Allergen on the Filter 8

Spore of mold

First in the world

The ‘Allergen Clear system’ suppresses the influence of the allergen caught by the filter by controlling the temperature and humidity. 20 of Patent Pending

Cooling Operation To make condensing water.

Heating Operation To give moisture to the Filter to inactivate allergen

AIR Purify

Self-Clean Operation To dry up the indoor unit

Applied models SRK-ZIX, SRK-ZG, SRK-ZE


Clean Air This is the original and only technology to control the temperature and humidity for inactivating allergens

Allergen Clear Filter

Sterilization Mechanism

Enzyme + Urea deactivates allergens and kills bacteria

Urea H2N-

Enzyme

Slack of high order structure

Reduction in a molecule

-COOH

Protein structure of allergen A molecule is decomposed

Rate of inactivation against allergens collected on the filter 93.6%

100

The allergen clear filter deactivates pollen lice and allergens that live on cat skin etc. The deactivation secret is the Enzyme-urea compound. It deactivates not only allergens but some bacteria, moulds and viruses. Even if allergen, mould, virus or bacteria fly off the filter they are deactivated so the air in your room is kept fresh.

Inactivation rate(%)

Virus i

Virus p

50

0

House dust mite A species of mite *1

*1

Cedar pollen *2

Epithelium of cat *2

*3

*3

First in the world

Natural Enzyme Filter

Conventional Filter

Analysis Zone

The enzymes used in these filters are naturally occurring lytic enzymes. Lytic enzymes attack cell walls of microorganisms trapped on the filter and destroy them. The Natural Enzyme Filter will clean and sanitize air passing through it.

99.0%

72.7%

Helps to destroy fungi and bacteria, also effective on viruses and allergenic compounds (Cat hair, dust mite, pollen etc.)

Enzyme filter

99.9%

83.5%

83.5%

Enzyme Filter Airflow

*1 Test method: ELISA colorimetric method / ELISA fluorescent method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536 *2 Test method: ELISA colorimetric method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536 *3 Test method: TCID (Infection value 50%) Laboratory: Foundation of Kitazato Environmental Science Center, No.15-0145

Analysis Zone

Enzyme's sterilizing mechanism Bacterium Enzyme

Enzyme

Coupling

Powerful sterilizing effect

Cell wall Filter fiber

The deodorizing ability of this filter can be easily restored simply by cleaning and exposing to the sunlight

Photocatalytic Washable Deodorizing Filter

This filter will keep the air fresh by deodorizing the molecules that cause odours. The deodorizing effect can be restored by washing with water and then drying under the sun. This filter maintains its deodorizing effect even after many repeat uses. Used in models Indoor Unit

SRK-ZIX

SRK-ZE

SRK-ZG

SRF-ZIX

Allergen Clear Filter

1pc

1pc

1pc

-

-

Natural Enzyme Filter

-

-

-

1pc

1pc

Photocatalytic Washable Deodorizing Filter

1pc

1pc

1pc

1pc

1pc

Filter

SKM-ZG

R e s i d e n t i a l A i r C o nditioners

9


Advanced Technology

Anti-microbial specifications and design will deliver cleanliness and safety Applied models

Anti-microbial indoor fan

All SRK, SKM

Anti-microbial treatment

Anti-microbial indoor fan The indoor fan has undergone anti-microbial treatment to resist growth of mould and germs. Mould creating odours which can occur when an air conditioner is not in operation are prevented. ·Intestinal bacteria (Escherichia coli IFO 3972) ·Staphylococcus aureus subsp. aureus IFO 12732 Testing Authority: Japan Food Analysis Center Test Results Issued: 2004-4-7. Test Report No.: 104034022-001 Tests were conducted with reference to the antimicrobial strength tests in JIS Z 2801 2000 “Antimicrobial Products-Antimicrobial Test Method” –5.2 Antimicrobial Effects: Test Methods for Plastic Products, etc. ·Apergillus niger IFO 6341 Testing Authority: Japan Food Analysis Center Test Results Issued: 2004-4-23. Test Report No.: 104034022-002 Tests were conducted with reference to the antimicrobial strength tests in JIS Z 2801 2000 “Antimicrobial Products-Antimicrobial Test Method” –5.2 Antimicrobial Effects: Test Methods for Plastic Products, etc.

Comparison of growth of bacteria and mold on fan surfaces (microscopic image)

without with Anti-microbial Anti-microbial

without with Anti-microbial Anti-microbial

Aspergillus niger IFO 6341

Escherichia coli IFO 3972

In tests conducted at the Mitsubishi Heavy Industries Nagoya Research Lab, 24 hrs after contact with bacteria, cultured on agar media.

Live Bacteria Count on Measured Test Pieces

Tested Contaminant

Escherichia coli IFO 3972 coli Staphylococcus aureus Aspergillus niger

Test Pieces

Immediately after contact

Not treated

Measurement 1 1.9 x 105

After 24 hrs at 35°C

Test piece 1 Not treated

<10 3.8 x 106

<10 4.9 x 106

<10 7.2 x 106

Immediately after contact

Not treated

1.4 x 105

1.6 x 105

1.3 x 105

After 24 hrs at 35°C

Test piece 1 Not treated

<10 8.6 x 105

<10 4.5 x 105

<10 3.6 x 105

Immediately after contact

Not treated

1.5 x 104

2.2 x 104

1.6 x 104

After 24 hrs at 35°C

Test piece 1 Not treated

<10 1.0 x 104

<10 1.2 x 104

<10 2.5 x 104

Test Pieces 1) Products with Antimicrobial and Antifungal Treatment

10

Bacteria Count Per Test Piece Measurement 2 Measurement 3 1.6 x 105 1.3 x 105

Measurement


Advanced Technology

Applied models SRK-ZIX, SRK-ZE, SRK-ZG, SCM-ZG SRF-ZIX

Wide Operation Range Heating and cooling operations are possible at an outdoor temperature as low as –15°C -15°C

Our new advanced technology has improved the heating and cooling operation range. Units can be installed when heating or cooling operation is required at low ambient conditions down to -15°C.

+21°C

Heating

-15°C

40

30

20

10

0

-10

-20

+46°C

Cooling

50

For the capacities under low temperature conditions, refer to technical manual.

Silent airflow and long reach

Quiet operation This is the secret of quiet operation The combination of the jet airflow system and serration stabilizer configuration ensures uniform breeze to every corner of the room. It also makes it possible to lower the operation noise further by minimizing the interaction between airflow and the fan.

Applied models SRK50/60ZIX, SRF-ZIX

r everyday

ises in ou

miliar no

with fa omparison

C

Nor

60dB

21dB

ns

ersatio mal conv

70dB

life

e

Quiet offic

50dB

a rary Late night in ea burban ar typical su

In the lib

40dB 30dB 20dB

60dB

50dB

40dB

30dB

21dB

10dB

SRK20ZIX-S

0dB

(In the Cooling Lo mode)

Three sensors Control of room temperature and humidity is very important for people to live a comfortable life. Use of three sensors to control indoor temperature, indoor humidity and outdoor temperature enable the unit to obtain optimum air-conditioning.

Sensor for indoor temperature

Sensor for outdoor temperature

Sensor for indoor humidity

Applied models All SRK, SKM, SRF

Applied models SRK50/60ZIX, SRK-ZE SRF-50ZIX

Washable filter and easy cleaning of air inlet panel Removing the air filter is quite easy. Keeping the air filter clean is an effective way to save energy and keep the original powerful performance of your unit. The air inlet panel is also removable and can be cleaned easily.

Long piping length Piping length has been extended and design flexibility has been improved.

Maximum pipe length

30m

Maximum height difference

20m

R e s i d e n t i a l A i r C o nditioners

11


Product line up R410A Model

SRK-ZIX series

SRF-ZIX series

Floor Standing type

2.5

20ZIX-S

25ZIX-S

35ZIX-S

50ZIX-S

25ZIX-S

35ZIX-S

50ZIX-S

2.8

6.3

7.1

7.5

8.0

63ZE-S1

71ZE-S1

80ZE-S2

80ZE-S1

NEW 60ZIX-S

NEW

HEAT PUMP DC INVERTER

Capacity Range (kW : Rated cooling capacity) 3.5 4.0 5.0 6.0

2.0

SRK-ZE series

SRK-ZG series 20ZG-S

Model

SKM

25ZG-S

35ZG-S

2.0

2.2

2.5

2.8

3.5

20ZG-S

22ZG-S

25ZG-S

28ZG-S

35ZG-S

4.0

4.5

4.8

5.0

5.6

6.0

6.3

7.1

8.0

50ZG-S

Wall mounted type 60ZG-S

71ZG-S

SRRM Ceiling Concealed type INVERTER Free-Multi

25ZF-S

35ZF-S

50ZF-S

60ZF-S

25ZF-S

35ZF-S

50ZF-S

60ZF-S

STM

4way ceiling cassette type 600 x 600

Super Compact type

2 rooms OUTDOOR UNIT

SCM

40ZG-S

45ZG-S

3 rooms

3 rooms

48ZG-S

60ZG-S

4 rooms 80ZG-S

12


Functions Filter Allergen

Filter SUN

Filter

Allergen Clear Filter The filter breaks down the pollen, lice, and all allergens that live on cat skins, etc. and deactivates them.

Enzyme

Filter

Photocatalytic Washable Deodorizing Filter

Natural Enzyme Filter Enzymes used in the filter are naturally occurring lytic enzymes which attack cell walls of microorganisms trapped on the filter and destroy them.

It keeps air fresh by deodorizing the molecules causing odor. The deodorizing ability can be easily restored simply by cleaning and exposing to the sunlight.

Comfortable Functions Fuzzy Auto Mode

"HI POWER" Operation

Automatically the unit determines its operating mode and temperature and setting based on a fuzzy calculation and adjusts the inverter frequency.

The unit can operate continuously in HI POWER mode for 15 minutes. This mode is used to reach the desired temperature quickly. Sta

The air conditioner automatically selects from heating, cooling or dry operation.

r t Sp

t ur

Automatic Operation

3HOT K eep

Three "Hot" System ‘Hot start’ enables the unit to begin operation immediately. ‘Hot spurt’ a fast heating system that works to increase the temperature setting by two degrees. ‘Hot keep’ used during the automatic defrost cycle to prevent cool air being circulated. These three operational control systems help ensure comfortable and efficient heating.

Comfortable Air Flow Functions 3D Auto Auto

You can choose the best heating or cooling pattern with the touch of a button.

Auto Flap Auto Flap Mode

COOLING & DRY Horizontal blowing

The unit automatically selects the optimal angle whatever the operation mode.

Air Scroll Air Scroll The swing of the flap causes the air flow to spiral and the breeze reach all corners of the room.

HEATING Slant forward blowing

COOLING & DRY Thick line : moves quickly Thin line : moves slowly HEATING Thick line Thin line

Memory Memory Flap While the flap is swinging it can be stopped at any angle. The flap returns to this position next time the unit starts operation.

UP/DOWN Up/Down Flap Swing

SWING FLAP

The Up/Down flap can be adjusted to Flap moves up and down continuously. the preferred angle anywhere between horizontal and perpendicular.

Lateral Swing

Lateral swing The louver swings from right to left automatically. Louver angle can be fixed in any desired position.

Air outlet Air outlet selection selection Both lower and upper air outlets and upper air outlet can be selected.

Positioning of Installation

: moves quickly : moves slowly

Positioning You can set the left-right air flow directions when you of installation installed the air conditioner near the side wall by remote controller operation.

Convenience & Economy Functions 24-hour On/Off Programmable Timer

On Timer On Timer This enables the operation to start a little earlier so that the room is near to set temperature at ON time.

Economy Economy Mode The unit achieves effective energy saving operation while still keeping a comfortable cooling or heating operation.

Dry Operation DRY

The unit dehumidifies the room by intermittent cooling operation.

24h Timer By combining a start timer with a stop timer you can register two

timer operations a day. Once set timers will start or stop the system at the specified time of the day repeatedly.

OFF Timer Off Timer The unit stops at the specified time.

Sleep

Sleep Mode The room temperature is automatically controlled during that set sleep mode period ensuring that the room temperature will not get too hot or cold.

Maintenance & Prevention Functions

MC

Microcomputer-Operated Defrosting This function automatically eliminates frost and helps minimize excessive operation in other modes.

Detachable Detachable Indoor Air Inlet Panel

The air inlet panel on the indoor unit opens and closes easily making filter cleaning simple. The suction panel can be easily removed.

Self-Diagnostic Function Self Diagnostic If the air conditioner malfunctions an internal microcomputer

When removing the air inlet panel for internal cleaning or other reason, open the grill by 65 degrees and then pull it to the side.

runs a self diagnosis. Inspection and repair should be performed by authorized dealers.

Others Back-up Back-up Switch Switch On the indoor unit there is a back up on/off switch. The system will operate in the previous mode.

Auto Auto Restart Function Restart Power blackout auto restart function records the operational status

of the air conditioner immediately prior to being switched off by power supply interruption. The unit automatically resumes operations in that mode and temperature set point after the power has been restored.

24-hour ION 24h ION

Luminous

The air conditioner body has a tourmaline coated sheet. Negative ions (2,500 -3,000/cc) are generated when the air conditioner is not running, allowing you to experience them without incurring any electrical cost.

Luminous Button With wireless “Luminous” remote controls that even “glow in the dark”, it is possible to operate all desired functions of the unit with the click of a button.

R e s i d e n t i a l A i r C o nditioners

13


INVERTER HEATPump PUMPModel MODEL(High (HighCOP) COP) Inverter Heat

SRK-ZIX series

NEW

R410A

SRK20ZIX-S, SRK25ZIX-S, SRK35ZIX-S SRK50ZIX-S, SRK60ZIX-S

SRC20ZIX-S, SRC25ZIX-S, SRC35ZIX-S

SRC50ZIX-S, SRC60ZIX-S

FUNCTION

Allergen

SUN

Comfortable Functions

Comfortable Air Flow Functions Auto Flap Memory UP/DOWN Lateral

Filter Filter

Convenient & Economy Functions Economy OFF Timer Sleep

On Timer 24h Timer

DRY Others Back-up Auto Switch Restart

Swing

Auto

Refrigerant pipe length Positioning of installation

Maximum pipe length

Maximum pipe length

Maximum height difference

Maximum height difference

15m

Maintenance & Prevention Functions Self Detachable Diagnostic

MC

30m

10m

20m

SRK20ZIX-S SRK25ZIX-S SRK35ZIX-S

Luminous

SRK50ZIX-S SRK60ZIX-S

24h ION

■ SPECIFICATIONS Model

opera ti on al d at a

R a t e d C a p a c i t y Cool/Heat P o w e r I n p u t C o ol/Heat

SRK20ZIX-S

SRK 6 0 Z I X - S

kW

2.0/2.5

2.55/3.13

3.5/4.3

5.0/6.0

6.0/6.8

0.35/0.45

0.49/0.595

0.845/0.96

1.30/1.35

1.8 6 / 1 . 6 7 3. 2 3 / 4 . 0 7

5.71/5.56

5.20/5.26

4.14/4.48

3.85/4.44

Stars

6/6

6/6

6/6

6/6

4/5.5

C u r re n t C o o l / H e at (MAX)

Amp

1.9/2.3

2.4/2.9

4.0/4.5

6.0/6.2 (10)

8.5 / 7 . 7 ( 1 2 )

39/21

41/22

43/22

45/26

47/26

l/s

192/200

208/217

225/233

225/275

24 2 / 2 8 3

S o u n d P re s s u re Level Hi/Lo Fan A i r f l o w C o o l / H e at Hi Fan

kW

3.2

3.4

3.9

6.3

7.0

kW/h

0.96

1.04

1.23

2.06

2.45

3.33

3.27

3.17

3.06

2.86

H2 COP D i m e n s i o n s ( h x wxd) We i g h t

mm kg

Filters Drain Hose

309x890x220 15 Allergen Clear x 1 Photocatalytic Washable Deodorising x 1

mm ø

16

P o w e r S o u rc e D i m e n s i o n s ( h x wxd) o ut door

SRK50ZIX-S

E n e r g y l a b e l C o ol/Heat

H2

14

SRK35ZIX-S

kW/h

E E R / C O P C o o l / Heat

H2 Power Input

in door

SRK25ZIX-S

We i g h t

1 Phase 240V 50Hz mm

590x780(62)x290

kg

38

S o u n d P re s s u re Level S o u n d P o w e r L e vel (AS/NZS1217.4)

dB(A)

C o m p re s s o r

640x800(71)x2 9 0 43

47

50

48

51

60

63

62

65

Rotary

Scroll

R e f r i g e r a n t R 4 1 0A

kg

1.2

1.4

R e f r i g e r a n t P i p i ng

mm ø

6.35/9.52

6.35/12.7


High Efficiency Industry leading COP levels Our new models, SRK20/25/35ZIX-S have reached perhaps the highest level of COP (coefficient of performance) in the industry. There was a full model change both of indoor and outdoor units. Our advanced technologies have been applied to our larger models: SRK50/60ZIX-S. 6.0 5.5

5.71 5.41

5.45

5.56

6.0 5.5

6.0

5.00

5.20

5.08

5.26

5.0

5.0

5.0

4.5

4.5

4.5

4.0

4.0

4.0

3.5

3.5 SRK20ZIX-S

CURRENT NEW

5.5

4.02

4.14

4.20

4.48

3.5 SRK25ZIX-S

SRK35ZIX-S

Movable air inlet panel By applying a movable air inlet panel, minimization of air resistance and advanced design are achieved.

Unification of indoor unit design All the ZIX series have the same design for indoor units with a sophisticated flat front panel.

Remote control Operation section

FAN SPEED button HI POWER/ECONO button TEMPERATURE button OFF TIMER button ON TIMER button SLEEP button CLEAN switch CANCEL button

OPERATION MODE select button ON/OFF (luminous) button AIR FLOW (UP/DOWN) button AIR FLOW (LEFT/RIGHT) button Page 6

3D AUTO button Page 6

ALLERGEN CLEAR button RESET switch

The above illustration shows all controls, but in practice only the relevant parts are shown.

R e s i d e n t i a l A i r C o nditioners

15


INVERTER HEATPump PUMPModel MODEL(High (HighCOP) COP) Inverter Heat

SRF-ZIX series

SRC25ZIX-S, SRC35ZIX-S

R410A

SRC50ZIX-S

NEW

SRF25ZIX-S, SRF35ZIX-S, SRF50ZIX-S

The highest COP level in the industry

EER in Cooling

Our experience, research and development efforts with the floor standing series have enabled us to reach the highest COP level in the industry. All models clear the 2010 MEPS level by a wide margin. Indoor units are totally new design with optimum balance of air outlet direction and sufficient air flow volume.

5.0

Enzyme SUN

Comfortable Functions

Filter Filter

Convenient & Economy Functions Economy OFF Timer Sleep

Others Back-up Auto Switch Restart

On Timer 24h Timer

DRY

4.8

5.0 3.33

4.5

3.9

4.0

FUNCTION

COP in Heating

2.93

3.33

4.0

4.0

3.6

3.5

3.5

3.0

3.0

2.5

Comfortable Air Flow Functions Auto Flap Memory UP/DOWN Air outlet selection

4.7

4.5

3.9

2.5 SRF25ZIX-S SRF35ZIX-S SRF50ZIX-S

SRF25ZIX-S SRF35ZIX-S SRF50ZIX-S

Refrigerant pipe length

Maintenance & Prevention Functions Self Detachable Diagnostic

MC

Maximum pipe length

Maximum pipe length

Maximum height difference

Maximum height difference

15m

30m

10m

Luminous

20m

SRC25ZIX-S SRC35ZIX-S

24h ION

SRC50ZIX-S

■ SPECIFICATIONS Model

op erat i on al d at a

R a t e d C a p a c i t y Cool/Heat P o w e r I n p u t C o ol/Heat

SRF25ZIX-S

SRF35ZIX-S

kW

2.5/3.4

3.5/4.5

5.0/6.0

kW/h

0.521/0.723

0.980/1.124

1.390/1.5 4 0 3.60/3.9 0

E E R / C O P C o o l / Heat

4.80/4.70

3.93/4.00

Stars

6/6

6/6

5.5/5.5

C u r re n t C o o l / H e at (MAX)

Amp

2.6/3.6

4.1/5.2

6.4/7.1

38/26

39/28

35/30

l/s

150/175

153/178

192/20 0

S o u n d P re s s u re Level Hi/Lo Fan H2 H2 Power Input

kW

3.6

3.9

6.2

kW/h

1.100

1,270

2.100

3.071

2.952

H2 COP in door

D i m e n s i o n s ( h x wxd) We i g h t

3.273 mm kg

660x860x238 18

Filters Drain Hose

19 Natural Enzyme x 1 Photocatalytic Washable x 1

mm ø

16

P o w e r S o u rc e

o ut door

D i m e n s i o n s ( h x wxd)

16

SRF50ZIX - S

E n e r g y l a b e l C o ol/Heat

A i r f l o w C o o l / H e at Hi Fan

We i g h t

1 Phase 240V 50Hz mm

590x780(62)x290

kg

38

S o u n d P re s s u re Level S o u n d P o w e r L e vel (AS/NZS1217.4)

dB(A)

C o m p re s s o r

640x800(71 ) x 2 9 0 43

47

50

60

63 Rotary

2.93

48 62 Scroll

R e f r i g e r a n t R 4 1 0A

kg

1.2

1.4

R e f r i g e r a n t P i p i ng

mm ø

6.35/9.52

6.35/12. 7


High Efficiency Sophisticated Design With a classy semi flat front panel in chic white, the new series fits in all kinds of rooms and creates a relaxing atmosphere. Choice of wall hanging, floor standing or behind gallery installation is available.

Quiet Operation The optimum balance of air outlet direction and sufficient air flow volume means the sound level has been minimized. The level of SRF25ZIX-S in the cooling lo mode is only 26dB(A).

Auto air outlet selection Heating operation:

Cooling operation:

When both lower and upper outlets operation with Auto fan speed mode is selected, the lower outlet will be kept closed for twenty minutes after the start or until room temperature is close to reaching the set point. Then the air outlet will change to both outlets. That state will be maintained until the switch is turned off. Automatic adjustment of lower air outlet direction prevents stirring up of warm air and keeps optimum comfort at floor level.

When both lower and upper outlets operation is selected in Cooling or Dry operation, both outlets are kept open for sixty minutes after the start or until room temperature is below set point. Then the air outlet will change to the upper outlet. That state will be maintained until unit is switched off. In case both outlets operation with Auto fan speed mode is selected, the upper outlet will be kept closed for ten minutes after the start or until room temperature is close to reaching the set point. Then the air outlet will change to both outlets in order to spread comfort air to every corner.

Installation workability

Convenient to use operation

Piping and drain hose connection can be selected out of 6directions.

Besides on/off operation, simultaneous lower and upper air outlets or upper outlet can be selected by the air flow direction button. Further control can be arranged by the remote control.

Right Rear Downward

Left rear

Left

Left downward

R e s i d e n t i a l A i r C o nditioners

17


Inverter Heat Pump Model (High COP)

SRK-ZE series

R410A

SRK63ZE-S1, SRK71ZE-S1 SRK80ZE-S1, SRK80ZE-S2

Refrigerant pipe length Maximum pipe length

SRC63ZE-S1, SRC71ZE-S1 SRC80ZE-S1, SRC80ZE-S2

30m

FUNCTION

Allergen

SUN

Maximum height difference

20m

Comfortable Functions

SRK63ZE-S1, SRK80ZE-S1 SRK71ZE-S1, SRK80ZE-S2

Filter Filter

Comfortable Air Flow Functions Auto Flap Memory UP/DOWN Lateral

Convenient & Economy Functions Economy OFF Timer Sleep

Swing

On Timer 24h Timer

DRY

Maintenance & Prevention Functions Self Detachable Diagnostic

Others Back-up Auto Switch Restart

MC

Luminous 24h ION

■ SPECIFICATIONS Model

oper ati ona l da ta

R a t e d C a p a c i t y Cool/Heat P o w e r I n p u t C ool/Heat

SRK63ZEA-S1 kW

6.3/7.1

7.1/8.0

8.0/9.0

7.5/ 9 . 0

1.84/1.86

2.21/2.21

2.84/2.74

2.45/ 2 . 7 4

3.42/3.82

3.21/3.62

2.82/3.29

3.06/ 3 . 2 9

Stars

5/5

4.5/4.5

3/3.5

1.5/1 . 5 * *

C u r re n t C o o l / Heat (MAX)

Amp

8.0/8.1 (12)

9.6/9.6 (14)

S o u n d P re s s u re Level Hi/ULo Fan

dB(A)

43/26

45/26

46/26

l/s

310/350

333/375

350/375

A i r f l o w C o o l / H eat Hi Fan

D i m e n s i o n s ( h xwxd) We i g h t

kW

7

7.3

7.8

2.39

2.69

2.98

2.9

2.7

mm kg

15 Allergen Clear x 1 Photocatalytic Washable Deodorising x 1

mm ø

P o w e r S o u rc e D i m e n s i o n s ( h xwxd) We i g h t

2.6 318x1098x248

Filters Drain Hose

12.5/11.7 (16)

kW/h

H2 COP i nd oor

SRK80Z E A - S 2

kW/h

E E R / C O P C o o l /Heat

H2

ou td oor

SRK80ZEA-S1

E n e r g y l a b e l C ool/Heat

H2 Power Input

16 1 Phase 240V 50Hz

mm kg

59

dB(A)

47

56

S o u n d P o w e r Level (AS/NZS1217.4)

dB(A)

58

67

C o m p re s s o r

1 Phase 230V 50Hz 750x880x340

S o u n d P re s s u re Level

58 69 Twin Rotary

R e f r i g e r a n t R 4 10A

kg

1.9

R e f r i g e r a n t P i ping

mm ø

6.35/15.88

** Energy Star revision 2010 MEPS

18

SRK71ZEA-S1


Inverter Heat Pump Model

SRK-ZG series

R410A

SRK20ZG-S, SRK25ZG-S SRK35ZG-S

Refrigerant pipe length SRC20ZG-S, SRC25ZG-S SRC35ZG-S

Maximum pipe length

15m

Maximum height difference

FUNCTION

Allergen

SUN

10m

Comfortable Functions

SRK20ZG-S, SRK25ZG-S SRK35ZG-S

Filter Filter

Comfortable Air Flow Functions Auto Flap Memory UP/DOWN Lateral Swing

Auto

Positioning of installation

Convenient & Economy Functions Economy OFF Timer Sleep

DRY

On Timer 24h Timer

Maintenance & Prevention Functions Self Detachable Diagnostic

MC

Others Back-up Auto Switch Restart

Luminous 24h ION

■ SPECIFICATIONS Model

oper ati ona l da ta

R a t e d C a p a c i t y Cool/Heat P o w e r I n p u t C ool/Heat

SRK20ZG-S

SRK25ZGA-S

kW

2.0/2.7

2.5/3.4

3.5/4. 2

kW/h

0.44/0.62

0.62/0.93

1.05/1 . 1 4 3.33/3 . 6 8

4.55/4.35

4.03/3.66

E n e r g y l a b e l Cool/Heat

E E R / C O P C o o l/Heat Stars

6/6

6/5

5/5.5

C u r re n t C o o l / Heat (MAX)

Amp

2.2/2.8

2.9/4.1

4.5/4 . 9

S o u n d P re s s u re Level Hi/Lo Fan A i r f l o w C o o l / Heat Hi Fan H2 H 2 P o w e r I n p ut

35/21 l/s

36/22

i nd oor

We i g h t

kW

3.0

3.7

1.15

1.09

2.6

3.4

1 Phase 240V 50Hz mm

Drain Hose We i g h t

8.5 Allergen Clear x 1 Photocatalytic Washable Deodorising x 1

mm ø

16

mm

540x780x290

kg

S o u n d P re s s u re Level S o u n d P o w e r Level (AS/NZS1217.4)

268x790x199

kg

Filters D i m e n s i o n s ( h xwxd)

141/18 0

kW/h

P o w e r S o u rc e D i m e n s i o n s ( h xwxd)

40/2 3

127/145

H2 COP

ou t door

SRK35ZG A - S

35 47

dB(A)

48

58

C o m p re s s o r

62 Rotary

R e f r i g e r a n t R 410A

kg

R e f r i g e r a n t P i ping

mm ø

0.9

1.2 6.35/9.52

R e s i d e n t i a l A i r C o nditioners

19


Inverter Multi-Split Model

Inverter Multi-split System

R410A

The multi-split system allows a single outdoor unit to service up to four indoor unit configurations. Three different styles of indoor units can connect to a line up of 5 multi circuited outdoor units from 4.0kW to 13.5kW.

Ceiling Concealed type

SRRM

Wall mounted type

SKM

4way ceiling cassette type

STM

600 x 600

Super Compact type

20


High Efficiency

OUTDOOR UNIT

SCM40ZG-S, SCM45ZG-S SCM48ZG-S, SCM60ZG-S

SCM80ZG-S

■ CONNECTION OF REFRIGERANT PIPING Limit The maximum permissible length & height of the indoor and outdoor units and associated refrigerant piping is shown below.

height difference

SCM40ZG-S

SCM45ZG-S

SCM48ZG-S

SCM60ZG-S

SCM80ZG-S

length for one indoor unit

under 25m

under 25m

under 25m

under 25m

under 25m

total length for all rooms

under 30m

under 30m

under 40m

under 40m

under 70m

lower installation spot of the indoor unit A

under 15m

under 15m

under 15m

under 15m

under 20m

upper installation spot of the indoor unit B

under 15m

under 15m

under 15m

under 15m

under 20m

maximum height difference of the indoor units C

under 25m

under 25m

under 25m

under 25m

under 25m

30m

20m

40m

30m

40m

length of charge-less refrigerant pipe

SCM40ZG-S

SCM45ZG-S

B

SCM48ZG-S

B

C

B

C A

SCM60ZG-S

SCM80ZG-S

B

C

B

C

C

A A

A

SCM40ZG-S

■ OUTDOOR UNIT SPECIFICATION

SCM45ZG-S

A

SCM48ZG-S

2 Rooms

SCM60ZG-S

3 Rooms

SCM80ZG-S 4 Rooms

1 Phase 220~240V / 50Hz

Power Source Nominal Cooling Capacity (ISO T1)

kW

1.9 4.0 5.0

1.0 4.5 6.4

1.1 4.8 6.9

1.1 6.0 7.5

1.8 8 . 0 9 . 5

Nominal Heating Capacity (ISO H1)

kW

2.2 5.0 5.2

1.8 5.6 6.8

1.4 6.0 7.1

1.4 7.0 7.6

0.8 9 . 3 9 . 6

Efficiency (EER/COP)

kW

4.12/4.35

3.78/4.25

4.03/4.35

3.70/4.02

3.6 0 / 3 . 8 3

Running Current Nominal

Amp

5.3

6.2

6.3

8.0

Dimensions

mm

Weight Refrigerant

R410A

Sound Power Level (AS/NZS1217.4) Indoor Unit Combination

kg

44

kg

1.4

Range of Temp Operation

1.95

62

64

SKM

2.0 2.2 2.5 2.8 3.5kW

STM

2.5 3.5kW

SRRM Min / Max Indoor Connection

750 x 8 8 0 x 3 4 0

46 1.6

dB(A)

Cool C

o

66 3.15

65

66

2.0 to 6.0kW

2.0 t o 7 . 1 k W

2.5 3.5kW 4.0 ~ 5.7kW

51 2.2

2.5 3.5 5.0 6.0 k W 2.5 3.5 5.0 6.0 k W

2 units

Min / Max No of Connected Indoor Units

11.2

640 x 850 x 290

2 to 3 Units

4.0 ~7.0kW

4.0 ~ 8.5kW

Cooling -15 to 43 o

o

2* 3 t o 4 U n i t s

4.0 ~ 11.0kW

Heating -15 to 24 o

6.0 ~ 1 3 . 5 k W

o

*Only combination SKM60ZG + SKM60ZG & SKM60ZG + SKM71ZG combination can operate with 2 indoor units on a SCM80ZG

R e s i d e n t i a l A i r C o nditioners

21


Inverter Multi-Split System

Multi System INDOOR UNIT

R410A

Wall mounted type

SKM series FUNCTION

Enzyme SUN

Comfortable Functions

Filter Filter

Comfortable Air Flow Functions Auto Flap Memory UP/DOWN Lateral Swing

Auto

Positioning of installation

Convenient & Economy Functions Quiet OFF Timer Sleep

Maintenance & Prevention Functions Self Detachable Diagnostic

MC

On Timer 24h Timer

DRY

Others Back-up Auto Switch Restart

24h ION

Luminous

SPECIFICATIONS Item Cooling capacity Heating capacity Sound power level * Sound pressure level *

ISO-T1 ISO-T1 Cooling Heating Cooling Heating

Exterior dimensions (HXWXD) Net weight Clean filter Liquid line Gas line

Piping

Model

SKM20ZG-S

SKM22ZG-S

SKM25ZG-S

SKM28ZG-S

SKM35ZG-S

SKM50ZG-S

kW kW dB(A) dB(A) dB(A) dB(A) mm kg

2.0 3.0 51 55 35 37

2.2 3.2

2.5 3.4 52 56 36 38

2.8 4.0 54 58 38 40

3.5 4.5 55 59 39 41

5.0 5.8 61 62 45 44

52 56 36 38

268X790X199 8.5 Natural Enzyme Filter X 1, Photocatalytic Washable Deodorizing Filter X 1

mm ø mm ø

6.35 9.52

12.7 SCM60,80ZG-S

SCM40,45,48,60,80ZG-S

OUTDOOR UNITS TO BE COMBINED

The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB. Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions.

*

FUNCTION

Enzyme SUN

Comfortable Functions

Filter Filter

Comfortable Air Flow Functions Auto Flap Memory UP/DOWN Lateral Auto

Swing

Positioning of installation

Convenient & Economy Functions Quiet OFF Timer Sleep

On Timer 24h Timer

DRY

Maintenance & Prevention Functions Self Detachable Diagnostic

MC

Others Back-up Auto Switch Restart

SPECIFICATIONS Item Cooling capacity Heating capacity Sound power level * Sound pressure level *

ISO-T1 ISO-T1 Cooling Heating Cooling Heating

Exterior dimensions (HXWXD) Net weight Clean filter Piping

Liquid line Gas line

OUTDOOR UNITS TO BE COMBINED

Model

SKM60ZG-S

SKM71ZG-S

kW kW dB(A) dB(A) dB(A) dB(A) mm kg

6.0 6.8 59 59 43 43

7.1 8.0 60 60 44 44

mm ø mm ø

318X1,098X248 15 Natural Enzyme Filter X 1, Photo catalytic Washable Deodorizing Filter X 1 6.35 12.7 SCM60,80ZG-S

SCM80ZG-S

The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB. Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions.

*

22

24h ION

Luminous


High Efficiency Ceiling Concealed type

SRRM series FUNCTION Comfortable Functions

Convenient & Economy Functions On Timer Quiet OFF Timer 24h Timer DRY

Maintenance & Prevention Functions Others Back-up Self Auto Diagnostic Switch Restart

MC

SPECIFICATIONS Model

Item Cooling capacity Heating capacity

ISO-T1 ISO-T1 Cooling Heating Cooling Heating Cooling Heating

Sound power level * Sound pressure level * Air flow Q’ty (Hi)

Exterior dimensions(HXWXD) Net weight Piping OUTDOOR UNITS TO BE COMBINED

SRRM25ZF-S

SRRM35ZF-S

SRRM50ZF-S

SRRM60ZF-S

2.5 3.4 53 54 38 39 8.5 10.0

3.5 4.5 55 56 40 41 9.0 11.0

5.0 5.8 60 60 46 46 10.5 13.0

6.0 6.8 63 63 49 49 12.5 15.0

kW kW dB(A) dB(A) dB(A) dB(A) m3/min m3/min mm kg mm ø

230X740X455 22 Liquid line: 6.35 Gas line: 9.52 SCM40,45,48,60,80ZG-S

23 Liquid line: 6.35 Gas line: 12.7 SCM60,80ZG-S

The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB. Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions.

*

4way ceiling cassette type

STM series

600 x 600

Super Compact type

FUNCTION Comfortable Functions

Comfortable Air Flow Functions Auto Flap Air Scroll Memory UP/DOWN

Convenient & Economy Functions On Timer Quiet OFF Timer 24h Timer DRY

Maintenance & Prevention Functions Self Diagnostic

MC

Others Back-up Auto Switch Restart

SPECIFICATIONS Item Cooling capacity Heating capacity Sound power level * Sound pressure level * Air flow Q’ty (Hi) Exterior dimensions (HXWXD) Net weight

Model ISO-T1 ISO-T1 Cooling Heating Cooling Heating Cooling Heating Main unit Panel Main unit Panel

Piping OUTDOOR UNITS TO BE COMBINED

kW kW dB(A) dB(A) dB(A) dB(A) m3/min m3/min mm mm kg kg mm ø

STM25ZF-S

STM35ZF-S

STM50ZF-S

STM60ZF-S

2.5 3.4 51 51 35 35 8.0 9.0

3.5 4.5 54 54 38 38 9.0 10.0

5.0 5.8 56 56 40 40 10.0 11.0

6.0 6.8 63 63 47 47 13.0 14.0

14.5

14.5

248X570X570 35X700X700 14

14 3.5

Liquid line: 6.35 Gas line: 9.52 SCM40,45,48,60,80ZG-S

Liquid line: 6.35 Gas line: 12.7 SCM60,80ZG-S

The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB. Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions.

*

R e s i d e n t i a l A i r C o nditioners

23


Control Option

Control option

Wired remote control can be connected interface

Model

Interface

SRK63/71/80ZE-S1/2 SKM60/71ZG-S SRRM, STM

not required

SRK20~50ZG-S SKM20~50ZG-S SRK20~60ZIX-S SRF25~50ZIX-S

Remote Control

RC-E1R

SC-BIK1-E SC-BIKN-E

RC-E3

Can be connected to SUPERLINK- II Model SRK20~60ZIX-S SRF25~50ZIX-S

Interface SC-BIKN-E SC-ADN-E

Remote Control RC-E3

RAC series

RAC series

(SRK20~60ZIX-S)

SC-BIKN-E

(SRF25/35/50ZIX-S)

PAC VNV series

SC-BIKN-E

SC-SL2N-E RC-E3

RC-E3

RC-E3

SC-ADN-E

SC-ADN-E

SC-ADN-E

CnT terminal is equipped CnT

common output1 (run) output2 (heat) output3 (comp on) output4 (alarm) in put

XR1 XR2 XR3 XR4

XR1 XR2 XR3 XR4 XR5

Power source

XR5 XR1~4 : DC12v XR5 : 220~240V HOTEL

HOTEL

Remote surveillance system

24

36

Card key on-off

Humidifier linkage


High Dimensions Efficiency

Dimensions INDOOR UNIT

Unit: mm

Wall mounted type SRK20ZIX-S SRK25ZIX-S SRK35ZIX-S SRK50ZIX-S SRK60ZIX-S

SRK63ZE-S1 SRK71ZE-S1 SRK80ZE-S1 SKM60ZG-S SKM71ZG-S SRK80ZE-S2

881.9

4

21

19

(right,left)61.5

3

248

1098

3

Piping hole right (left)

Piping hole right

Terminal block

9

9

48

3.1

309

43.5

318

220

890

4 64

55

61.5 46.5

1098 51.2

55

60

60

46.5 61.5

26

Terminal block

122.1

55

SRK20ZG-S SRK25ZG-S SRK35ZG-S SKM20ZG-S SKM22ZG-S SKM25ZG-S SKM28ZG-S SKM35ZG-S SKM50ZG-S 788 60

27

60

45

45

17.5

199

790

3

Terminal block

9 60

268

Piping hole right(left)

45

Floor standing type SRF25ZIX-S SRF35ZIX-S SRF50ZIX-S 840 157.2

85.3

10 22.7

198

100 60 185

55

10 76.3

Screw point fasten the indoor unit(ø5) 25.5

860

238

6

Outlet for down piping (Refer to the above view)

12

Outlet for piping (on both side)

15 60 100 125

804

600

30.5

60

R e s i d e n t i a l A i r C o nditioners

25

37


Dimensions High Efficiency Dimensions INDOOR UNIT Unit: mm

4way ceiling cassette type STM25ZF-S

STM35ZF-S

STM50ZF-S

STM60ZF-S 570 243 104

Celling opening 660 (For conventional celling) Hanging bolt pitch 530

D

B

PANEL

E

A

35

45 or more

Hanging bolt pitch 530 350 319

197 137

93 196 250

C

68

541

Hanging fixture

202

*Please arrange VP25 connector sockets on the installer's part.

105

220

90

220

105

11

30 19

SRRM25ZF-S SRRM35ZF-S SRRM50ZF-S SRRM60ZF-S

Model 25,35ZF-S 50,60ZF-S Gas pipe connecting port ø 9.52(Flare) ø 12.7(Flare) Liquid pipe connecting port ø 6.35(Flare) Drain line tube connecting port VP25* Power intake Hanging bolt (M10 or M8)

43

Drain hose (accessory) To be installed at site

Ceiling Concealed

Description

A B C D E

Air intake

413 700

Air outlet Control box

Mark

Terminal block 230

B

55 44

Air outlet

150

148 170

ø 4X8(Holes for tapping screws)

A

325

540

100

740 670 (Suspension bolts pitch)

Drain hose (Connection opening diameter ø16)

35

236 135

38 78

255

455

455

Controller

515 (Suspension bolts pitch)

30

35

Air inlet

30

100

Hanging bolt (M8X4)

106

A B

30

740

Description 25,35ZF-S 50,60ZF-S Model Gas pipe connecting port ø9.52(Flare) ø12.7(Flare) ø6.35(Flare) Liquid pipe connecting port

Mark

OUTDOOR UNIT Unit: mm

Drain holes (ø20.5)

510 780

158.4

2-R6

89

17.9

2-15.5 x 12 510 800

17.9 201

14.8

14.8

69.4

327.3

390.6 111.6

50.6 12

312.5 351.6

43.5

327.3

290

290

312.5

63.4

390.6

83.5

12

24.3

Drain holes(ø20)

SRC50ZIX-S SRC60ZIX-S

Anchor bolt hole (M10X4places)

351.6

50.6

24.3

SRC20ZIX-S SRC25ZIX-S SRC35ZIX-S

71.2

61.9 Terminal block Pipe/cable draw-out hole

Terminal block 148.4

42.5 93

Flare connection ø9.52

12.4

97.7 15.8

Service valve(gas)

Service valve (Liquid) Flare connection ø6.35 (1/4'')

Check joint

42.5

Flare connection ø6.35

40°

26

38

33.5

Service valve(liquid) 640

33.5

40°

592.6

138.4

Service valve (Gas) Flare connection ø12.7 (1/2'')


High Efficiency OUTDOOR UNIT Unit: mm

SRC20ZG-S SRC25ZG-S SRC35ZG-S Drain holes(ø20)

12

111.4 99.4

290

312.5 350

43.1

23.5

50

313.1

104.9

2-16x12 510 780

14

349.5 439.1

165.1

18.9 61.9

Terminal block Service valve (Liquid) 138.4

Flare connection ø6.35 (1/4'')

95.9

14

40

40

42.5

540

33.5

Service valve (Gas) Flare connection ø9.52 (3/8'')

SRC63ZE-S1 SRC71ZE-S1 SRC80ZE-S1 SRC80ZE-S2 532 19

Drain holes

61

150

580

2-ø15

25.8

150

880

19

61

418

380

15

340

47.5

223 60

29.8

87.9

Terminal block

Service valve(Liquid) 25.5

750

165.5

Flare fitting ø6.35(1/4'')

103.3

Flare fitting ø15.88(5/8'')

SCM40ZG-S SCM45ZG-S SCM48ZG-S SCM60ZG-S

SCM80ZG-S

50

223 15

60

532 Drain Holes

25.8

476 203.1

510 850

136.9 65

380 418 61

Elongated hole (2-12X16)

150

580 880

2-ø15

150

19

14

49.6

61

340

328

314

290

47.5

43.5

12

12

Drain hole

286.4

19

24.1

30

48.5

30 Service valve(Gas)

72.9

Liquid line service valve A Unit (ø6.35) Gas line service valve A Unit (ø9.52)

Liquid line service valve D Unit (ø6.35) Gas line service valve D Unit (ø9.52) Liquid line service valve C Unit (ø6.35) Gas line service valve C Unit (ø9.52)

52 525252525252

Ground terminal

742.2

Liquid line service valve B Unit (ø6.35)

Liquid line service valve B Unit (ø6.35) Gas line service valve B Unit (ø9.52)

110.4

42.7 67.9

20°

100.3

34.6

Gas line service valve B Unit (ø9.52)

20°

15

124

Terminal block

Gas line service valve C Unit (ø9.52) (60 type only)

24.1

Liquid line service valve C Unit (ø6.35) (60 type only)

42.7 67.9

640

42.7

Terminal block

184.6

10

Liquid line service valve A Unit (ø6.35) Gas line service valve A Unit (ø9.52)

R e s i d e n t i a l A i r C o nditioners

27

39


Cool Only Wall Split System

SRK-CHVA series SRK10CHVA

Refrigerant pipe length Maximum pipe length

15m

SRC10CHVA

Maximum height difference

10m

SRK10CHVA

FUNCTION Comfortable Functions

Enzyme SUN

Filter Filter

Comfortable Air Flow Functions

Auto Flap

Memory

UP/DOWN

Convenient & Economy Functions On Timer OFF Timer Sleep 24h Timer DRY

Maintenance & Prevention Functions Self Detachable Diagnostic

MC

Others Back-up Auto Switch Restart

24h ION

Luminous

■ SPECIFICATIONS Model o pera ti onal da ta

R a t e d C a p a c i t y Cool Power Input Cool

SRK10CHVA kW

2.65

kW/h

0.77

EER

3.44

E n e r g y L a b e l C o ol

Stars

5

C u r re n t C o o l

Amp

3.5

S o u n d P re s s u re Level Hi/Lo Fan Airflow Hi Fan

36/22 l/s

o ut door

i n door

P o w e r S o u rc e Dimensions We i g h t

mm kg

Filters

268x790x224 8.5 Natural Enzyme x 1, Photocatalytic Washable Deodorising x 1

Drain Hose

mm ø

16

Dimensions

mm

540x780x290

kg

30

We i g h t S o u n d P o w e r L e vel (AS/NZS1217.4)

dB(A )

C o m p re s s o r Refrigerant R22 Refrigerant Piping

28

166 1 Phase 240V 50Hz

58 Rotary

kg

0.75

mm ø

6.35/9.52


Other Products

FD

series - Inverter Packaged System

FDTC

FDE

FDUM

FDT

FDC

FDU

KX6 M series - VRF Inverter Multi System

FDCKXEN6 1ø 11.2, 14.0 & 15.5kW (heat pump only)

FDCKXES6 3ø 22.4, 28.0 & 33.5kW • 11.2 to 136kW • 2 and 3 pipe VRF systems • Industry leading EER/COP • Reduced footprint outdoors • 69 indoor units available • Power cost distribution • Esolution design tool • 3 year warranty (conditional) • 1000m total pipe run • All compressors are inverter control • BAC net® LonWorks® interfaceWeb Gateway options • New SLA3 colour touch screen controls up to 128 indoors

FDCKXES6 3ø 40.0 - 136.0kW R e s i d e n t i a l A i r C o nditioners

29


Before starting use Heating performance

Refrigerant leakage

Indication of sound values

Use in snowy areas

The heating performance values (kW) described in catalog are the values obtained by operating at an outdoor temperature of 7 C and indoor temperature of 20 C as set forth in the ISO Standards. As the heating performance decreases as the outdoor temperature drops, if the outdoor temperature is too low and the heating performance is insufficient, use other heating appliances as well. The sound values are the values (A scale) measured in a chamber such as an anechoic chamber following the ISO Standards. In the actual installation state, the value is normally larger than the values given in the catalog due to the effect of surrounding noise and echo. Take this into consideration when installing.

Use in oil atmosphere

Avoid installing this unit in as atmosphere where oil scatters or builds up, such as in a kitchen or machine factory. If the oil adheres to the heat exchanger, the heat exchanging performance will drop, mist may be generated, and the synthetic resin parts may deform and break.

Use in acidic or alkaline atmosphere

If this unit is used in acidic atmosphere such as hot spring areas having high level of sulfuric gases or in alkaline atmosphere including ammonia or calcium chloride, places where the exhaust of the heat exchanger is sucked in, or at coastal areas where the unit is subject to salt breezes, the outer plate or heat exchanger, etc., will corrode. Please ask a dealer or specialist when you use an air conditioner in places differing from a general atmosphere.

Use in places with high ceilings

If the ceiling is high, install a circulator to improve the heat and air flow distribution when heating.

The refrigerant (R410A) used for Air conditioner is non-toxic and inflammable in its original state. However, in consideration of a state where the refrigerant leaks into the room, measures against refrigerant leaks must be taken in small rooms where the tolerable level could be exceeded. Take measures by installing ventilation devices, etc. Take the following measures when installing the outdoor unit in snowy areas.

路Snow prevention Install a snow-prevention hood so that the snow does not obstruct the air intake port or enter and freeze in the outdoor unit.

路Snow piling In areas with heavy snow fall, the piled snow could block the air intake port. In this case, a frame that is 50cm or higher than the estimated snow fall must be installed underneath the outdoor unit.

Automatic defrosting device

If the temperature is low, and the humidity is high, frost will stick to the heat exchanger of the outdoor unit. If use is continued, the heating performance will drop. The "Automatic defrosting device" will function to remove this frost. After heating for approx, three to ten minutes, it will stop, and the frost will be removed. After defrosting, hot air will be blown again.

Servicing the air-conditioner

After the air-conditioner is used for several seasons, dirt will build up in the air-conditioner causing the performance to drop. In addition to regular servicing, we recommend the maintenance contract (charged for) by a specialist.

Safety Precautions Air-conditioner usage target

The air-conditioner described in this catalog is a dedicated cooling/heating device for human use. Do not use it for special applications such as the storage of foodstuffs, animals or plants, precision devices or valuable art, etc. This could cause the quality of the items to drop, etc. Do not use this for cooling vehicles or ships. Water leakage or current leaks could occur.

Before use

, Always read the "User s Manual" thoroughly before starting use.

Installation

Always commission the installation to a dealer or specialist. Improper installation will lead to water leakage, electric shocks and fires. Make sure that the outdoor unit is stable in installation. Fix the unit to stable base.

Usage place

Do not install in places where combustible gas could leak or where there are sparks. Installation in a place where combustible gas could be generated, flow or accumulate, or places containing carbon fibers could lead to fires.

ABN 92 133 980 275

National Contact Information: Phone: 1300 138 007

Fax: 1800 644 329

www.mhiaa.com.au

Head Office-Sydney

Melbourne Branch

Brisbane Branch

9C Commercial Road Kingsgrove NSW 2208 PO Box 318 Kingsgrove NSW 1480 Tel: 1300 138 007 Fax: 1800 644 329

10 Derby Street, Collingwood VIC 3066 Tel: +61 3 9419 0699 Fax: +61 3 9419 0788

2/27 Kingtell Place Geebung QLD 4034 PO Box 124, Virginia QLD 4014 Tel: +61 7 3865 8788 Fax: +61 7 3865 6533

MRE SPARE PARTS

www.mrespareparts.com.au

Tel: +61 (0) 2 9600 7444

ISO9001

ISO14001

Our Air Conditioning & Refrigeration Systems Headquarters is an ISO9001 approved factory for residential air conditioners and commercial-use air conditioners (including heat pumps).

Our Air Conditioning & Refrigeration Systems Headquarters has been assessed and found to comply with the BIWAJIMA PLANT requirements of Mitsubishi Heavy Industries, Ltd. Air-conditioning & Refrigeration Systems Headquarters ISO14001.

Mitsubishi Heavy Industries, Ltd. Air-conditioning & Refrigeration Systems Headquarters Certified ISO 9001 Certificate number : JQA-0709

MITSUBISHI HEAVY INDUSTRIESMAHAJAK AIR CONDITIONERS CO., LTD. Certified ISO 9001 Certificate Number : 04100 1998 0813

Certified ISO 14001 Certificate number : JQA-EM0256

ISO 14001 Certificate 04104 1998 0813 E5 MITSUBISHI HEAVY INDUSTRIESMAHAJAK AIR CONDITIONERS CO.,LTD. Certificate Number : 04104 1998 0813 E5

MHIAA143_RAC Cat NOV2009

BIWAJIMA PLANT

Fax: +61 (0) 2 9600 8044

Because of our policy of continuous improvement, we reserve right to make changes in all specifications without notice.


Wall Split SRK series