Fujitsu leadsthe way. Fujitsu leads the way in design and technology with its most exciting range of innovative air conditioners. With a choice of individual and advanced systems in a variety of configurations, Fujitsu can provide the perfect solution for any environment. Whether it’s heating or cooling, come home to Fujitsu comfort.

Features Up/Down Swing Louvre

ON-OFF Timer

The up/down louvre automatically swings up and down.

ON-OFF timer can be set to operate once every 24 hours.

Right/Left Swing Louvre

Weekly Timer

The right/left louvre automatically swings in either direction.

Different on-off times can be set for up to 7 days.

Double Swing Automatic

Weekly + Setback Timer

Complex swing action of the louvres enables them to swing automatically in both horizontal and vertical directions.

Weekly + Setback timer can set temperature for two time spans and for each day of the week.

Automatic Louvre

Washable Panel

The position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.

Auto Shut Louvre

Long-life Ion deodorisation filter

The auto shut louvres close or open automatically when the unit stops or starts.

For details, see page 11.

Automatic Air Flow Adjustment

Apple-catechin filter

The micro-processor automatically adjusts the air flow to follow changes in room temperature.

For details, see page 11.

Auto Restart

V-PAM

Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

V-Pam Inverter technology increases the maximum output of the compressor significantly and enables high power and high efficiency.

Auto-Changeover

I-PAM

The unit automatically switches between heating and cooling modes based on the temperature setting and room temperature.

I-Pam inverter technology enables high output and high efficiency performance.

Sleep Timer The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.

Program Timer This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.

2

C

Cooling

H

Heating


FG0050_RETAIL08.qxd

27/8/08

1:10 PM

Page 3

Contents INVERTER TECHNOLOGY INVERTER TYPE NOCRIA CEILING WALL

6

WALL MOUNTED PLASMA

8

WALL MOUNTED

10

CASSETTE

12

FLOOR/CEILING UNIVERSAL

12

2 ROOM /4 ROOM MULTI SYSTEM

13

CONVENTIONAL TYPE 2 ROOM MULTI SYSTEM

15

“With over 100 different brands of air conditioners on the market, how do you know you’re choosing the right one? Well, my advice is to go with a name you can trust, which is why I bought a Fujitsu. No other company can match their wide range, exceptional economy and superior efficiency. And with their famous 5 year parts and labour warranty, it’s no wonder Fujitsu is Australia’s Favourite Air.”

3


FG0050_RETAIL08.qxd

27/8/08

1:10 PM

Page 4

Inverter technology What's an inverter?

Room Warming Speed

Through new, advanced technology, Inverter air conditioners are more

Room Set Temp. Temp. Inverter

economical to operate and quieter to run than conventional units.

Maximum Power Conventional

Inverter

They can handle greater extremes in temperature, are smoother and more stable in operation and reach the desired temperature more

Conventional

T/2

quickly than conventional air conditioners.

T

Power and Speed

Inverter control

Set Temp.

Set Temp.

The Inverter component allows the outdoor unit to vary its Temp.

Temp.

Temp. Temp.

Time

Power

unit. Thus, the Inverter model can achieve 30% more operating

On Off O n

Time

INVERTER MODEL

speed and output to match the required capacity of the indoor

Power

efficiency than conventional models and therefore, is much

Off

On Time

cheaper to run.

CONVENTIONAL MODEL

Comparison of cooling efficiency of DC compressor (against AC compressor)

DC twin rotary compressor

Compressor COP 100

The Fujitsu Inverter System is equipped with a state of the art DC twin rotary compressor. It can reach the room

DC twin rotary compressor

temperature you set 15%* quicker than conventional

90 COP (%)

DC Twin Rotary AC Twin Rotaly

80

models and precisely maintain it at a difference of just 0.5째C. Advanced DC twin rotary compressor makes operation at high power and high efficiency a reality. (Selected models only)

6

8

10

12

Cooling Capacity(kW)

High Energy Efficiency

50% Off

Approx.

The high efficiency DC Inverter Multi System offers energy saving operation and 50% higher efficiency than a constant-

DC Inverter Multi System

speed multi system. Improved Inverter cooling ratio prevents

Constant-Speed Multi System

a drop in capacity when operating under load conditions.

Stable & Comfort The air conditioner's output is stabilised at the optimum setting within the range from maximum to minimum to match the load, which is affected by factors such as the room temperature and the number

4

4

*Depends on room size and heat load.

Energy savings over 1 year

of people present.

2


FG0050_RETAIL08.qxd

27/8/08

1:10 PM

Page 5

I-PAM

This year

I-PAM control panel

Through advances in our inverter technology, Fujitsu has now introduced I-PAM (Intelligent Power Module-Pulse Amplitude Modulation) technology. I-PAM is able to extract superior performance capabilities by adding an IPM board to conventional inverter PAM control.

3.61

5 years ago

COP

3.01

(Coefficient of Performance) PAM board

IPM board

Energy saving and speedy heating only possible by I-PAM I-PAM control model

Our previous inverter model

I-PAM 1.

Temp.( C) 0

I-PAM control model

4

Temp.( C)

30

30

3

1

Our conventional type inverter model

0

20

6

9

20 7

10 20

30

40 Time

Start

10

20

30

40

Start

Compressor motor voltage and speed

Time

Heating 10cm from the floor

V-PAM

Rises rapidly

3.

Pleasant temperature in 10 minutes

4.

High power operation

5.

Energy saving operation

PREVIOUS INVERTER

8

2

10

2.

6

10

5

Heats in approximately 1/3 of the time of our previous inverter models

High

Power New model

6.

Incomplete energy saving

7.

Still cold

8.

Temperature rise is slow

9.

Pleasant temperature in approximately 30 minutes

Electricity charge

High

Conventional model

V-PAM inverter increases the maximum output of the compressor significantly and enables high power and high efficiency.

Conventional model

New model

Low

Low Output increased to greater than that of conventional model

G

Saving electricity cost.

V-PAM

V-PAM technology makes the compressor more powerful.

Comparison between V-PAM &conventional PAM. Voltage control of V-PAM Motor revolution Voltage control of conventional PAM

380V

H

High

240V

More compact than conventional models.

Voltage

G

Vertical interval of voltage is wide

Vertical interval of voltage

Vertical interval of motor revolution is narrow

Save Low Power energy Vertical interval of motor revolution is wide

Conventional PAM Control range between energy saving and high power is small because vertical interval of voltage and motor revolution is narrow.

V-PAM V-PAM achieves high power by increasing the voltage up to 380V and making the motor rotate faster and also saves energy in the stable state by making the motor rotate slower H

than that of conventional models by lowering the voltage.

5


FG0050_RETAIL08.qxd

27/8/08

1:11 PM

INVERTER

Page 6

Automatic filter cleaning air conditioner. The revolutionary NOCRIA ceiling wall models have vastly improved heating and cooling efficiency and energy saving. These elegant units are designed to sit very high on the wall, just 40mm below the ceiling and remain very unobtrusive. The automatic self cleaning filter system ensures highly efficient operation and the UV filter disinfects and deodorises the air.

Ceiling Wall

Nocria

®

Available only from selected outlets.

AWTZ14LB

AWTZ18LB

AWTZ24LB

Hi-EER: 4.12 (W/W)

Hi-EER: 3.289 (W/W)

Hi-EER: 3.02 (W/W)

Hi-COP: 4.44 (W/W)

Hi-COP:4.108(W/W)

Hi-COP: 3.62 (W/W)

C

4.20kW/14,300BTU/h

C

5.20kW/17,700BTU/h

C

7.40kW/25,300BTU/h

H

6.00kW/20,500BTU/h

H

6.70kW/22,900BTU/h

H

8.50kW/29,000BTU/h

Our unique technology achieved top energy efficiency in the industry. WORLD FIRST!

A

CAE Analysis

Energy saving by automatic filter cleaning function.

This function allows an energy saving of more than 25% a year and maintains a smooth air flow by preventing the filters from being clogged with dust. B

Computer-designed fan provides a larger air flow than conventional models.

A

New air trunk, which provides a smooth air flow & gap fan motor increase the maximum air flow by10% over that of conventional models. CAE: Computer Aided Engineering

B

C

WORLD FIRST!

C

Axial gap fan motor enables non-conventional high power and high efficiency.

Axial gap method

CONVENTIONAL MOTOR

NEW MODEL

Rotor is bounded by electromagnet.

Electromagnet

Rotor plate

Thin copper wire

Rotor plates are installed above & below electromagnets.

Rotor plate Thin copper wire reduced electric resistance.

Features (Compared to conventional models) • Compact size with 1.5 times more power output. • Self-driven method increases rotating efficiency by10%. • Our electromagnetic field simulation technology enables low vibration and low noise.

6

Electromagnet Area, which confronts magnetic attraction, is very narrow

Rotor plate Area which confronts magnetic attraction is very wide and generates high power.


FG0050_RETAIL08.qxd

27/8/08

1:11 PM

Page 7

Strong vertical air flow provides powerful floor level heating.

Healthy horizontal air flow does not blow cool air directly at the occupants in the room.

No.1 Heating capacity

Increased heat exchange efficiency

Comfortable heating area Approximately 2.5 times* (Our company comparison)

*Compared to Inverter Model AST13PSACW.

Increased heat exchange efficiency

Cooling range Approximately 1.7 times* (Our company comparison)

Big flap

Power diffuser (full open)

Automatic filter clean

Air is blown directly downward

Big flap

*Compared to Inverter Model AST13PSACW.

Power diffuser

Blown out horizontally

D

WORLD FIRST!

Entire filter is cleaned automatically in approximately 2 minutes. Since the filter is cleaned automatically, energy saving capability is displayed without regard to the load on the air conditioner. F

Energy saving. If the energy saving effect is maintained, filter cleaning once every two weeks is effective.

E

Three exhaustive sterilising and deodorising counter measures keep the air in the room clean.

WORLD FIRST!

STERILISING COUNTER MEASURE D

Antibacterial dust box Removes dirt and dust by double brushes. Dust collection is approximately twice that in the past. (Our Company Comparison). Dust box only needs to be emptied every two years.

Dirt and dust are thoroughly sterilised by titan apatite filter*

* Displays double the effect of a conventional optical medium

E

World First! Drives away bacteria and refreshes the air by UV (ultraviolet rays) illumination.

F

The heat exchanger also uses titan apatite.

and retains its property for a long time to suck in and remove

Titan apatite attracts bacteria and mould spores that pass

approximately 99.99% of cigarette odours and bacteria, etc.

through the filter and suppresses the growth of bacteria.

Inner drying operation prevents growth of mould, fungus and bad odour. This model is equipped with an inner drying function. After the power is turned off, the drying operation starts inside the air conditioner.

Covered in Beading Bacteria grows in beading and causes bad odour. After operation ends, by pressing the COIL DRY button a 30 minute speed cleaning operation will commence.

Removes Moisture Drying operation takes approx. 15 minutes.

Sterilisation

Remote controller

Ozone sterilisation operation takes approx. 15 minutes.

03 03

Frequently used parts are clearly

“Inner drying operation” and “ozone sterilising operation” keep the

visible at the centre. The operation

inside of the air conditioner clean at all times. That’s why air from

mode can be directly selected.

the air conditioner is always clean and high efficiency is achieved.

03

03

7


FG0050_RETAIL08.qxd

27/8/08

1:11 PM

Page 8

Minute dust particles are thoroughly collected by electrostatic filter and odours are suppressed through decomposition by using negatively charged ions. This filter design allows for high dust collection whilst maintaining clean odourless air.

Wall Mounted

INVERTER

Plasma

For ASTB09/12LD

Available only from selected outlets.

For ASTB18/24LD

ASTB09LD

ASTB12LD

ASTB18LD

Hi-EER: 4.252 (W/W Hi-COP: 4.44 (W/W)

Hi-EER: 3.843 (W/W) Hi-COP: 3.934 (W/W)

Hi-EER: 3.022 (W/W) Hi-COP: 3.609 (W/W)

C

2.60kW/8,900BTU/h

C

3.50kW/11,900BTU/h

C

5.20kW/17,700BTU/h

H

3.60kW/12,300BTU/h

H

4.80kW/16,400BTU/h

H

6.25kW/21,300BTU/h

For ASTB30LD

ASTB24LD

ASTB30LD

Hi-EER: 3.01 (W/W) Hi-COP: 3.51 (W/W)

Hi-EER: 3.05 (W/W) Hi-COP: 3.41 (W/W)

C

7.40kW/25,300BTU/h

C

8.10kW/27,663BTU/h

H

8.50kW/29,000BTU/h

H

9.20kW/31,419BTU/h

Original plasma air cleaning unit effectively cleans the air in the room.

Dirty Air

Plasma air filter mechanism

Washable filter Each time the filter is washed, it is restored to the same performance levels as when new.

High efficiency layout

Clean Air

8


FG0050_RETAIL08.qxd

27/8/08

1:11 PM

Page 9

Plasma air cleaner quickly removes small dust particles and odours.

Clean Air Earth conductor

Electrostatic filter

Plasma filter generates ions and ozone.

Polyphenol filter (Grapefruit seed ectract) Activated charcoal disinfecting & deodorising filter

Dirty Air Electric pole

Negatively-charged dust, etc. are attracted to the earth section and are collected by a disinfecting & deodorising filter.

Pet odour and the smell of cigarette smoke are removed by decomposition by weak ozone O3.

Collects dirt such as...

Absorbs odours such as...

House dust/Pet fur/Cigarette smoke/Dust

Cigarette smoke/Pet odour/Perspiration and Body odour.

mites/Mould spores and Pollen.

Performance Dust collection performance

Deodorising performance

Dust collection performance

Deodorizing performance

Acetic Acid Acetic acid

100

54.3%

70 60 50 40 0

5

10

15

20

25 30

100

Removal ratio

80

82.4%

60 40 20 0 0

10

Time (mins)

Test method: JEM 1417 Test room: 30m3, sealed room

Residual ratio %

80

Residual ratio %

Dust collection efficiency

90

Residual ratio %

Ammonia Ammonia

100

20 Time (mins)

30

Removal ratio

80

92.7%

60 40 20 0 0

10

20

30

Time (mins)

Test method: JEM1467 Test room : 1m3, acryl sealed box

Sterilisation effect by Polyphenol ceraglaze The following diagrams illustrate the effect of a 0.1ml specimen containing bacteria (approx. 107CFU/ml) being sterilised by polyphenol ceraglaze.

Tested by KITAZATO environment science centre Experiment bacteria: Staphylococcus Aures/Escherichia coli Test No. :15-0253. Test condition: at 20 degrees C/24 hour action

9


FG0050_RETAIL08.qxd

27/8/08

1:11 PM

INVERTER

Page 10

Energy efficient Fujitsu Comfort. The Fujitsu smart Inverter range reaches the desired room temperature faster and then constantly adjusts to maintain perfect Fujitsu Comfort. With its energy efficiency, it is up to 30% cheaper to run than conventional air conditioners.

Wall Mounted

For ASTA07/09

ASTA07JC* Hi-EER: 3.68(W/W) C

2.10kW/7,200BTU/h

ASTA09JC* For ASTA12

Hi-EER: 3.518(W/W) C

2.60kW/8,900BTU/h

ASTA12JC* Hi-EER: 3.150(W/W) C

3.50kW/11,900BTU/h

ASTA09LC

ASTA12LC

ASTA18LC

Hi-EER: 3.963(W/W) Hi-COP: 4.261(W/W)

Hi-EER: 3.801(W/W) Hi-COP: 3.869(W/W)

Hi-EER: 3.022(W/W) Hi-COP: 3.61(W/W)

C

2.60kW/8,900BTU/h

C

3.50kW/11,900BTU/h

C

5.20kW/17,700BTU/h

H

3.60kW/12,300BTU/h

H

4.80kW/16,400BTU/h

H

6.25kW/21,300BTU/h

* Cooling only models not shown. Design differs.

ASTA18JC

For ASTA18LC

Hi-EER: 3.69 (W/W) C

5.20kW/17,700BTU/h

ASTA24JC

Hi-EER: 3.21 (W/W) C

7.10kW/24,200BTU/h

ASTA30JC

Hi-EER: 3.01 (W/W) C

ASTA34JC C

9.70kW/33,100BTU/h

Cooling only

10

For ASTA18/24

8.00kW/27,300BTU/h

ASTA24LC

ASTA30LC

Hi-EER: 3.01 (W/W) Hi-COP: 3.516 (W/W)

Hi-EER: 2.989 (W/W) Hi-COP: 3.385(W/W)

C

7.40kW/25,300BTU/h

C

8.00kW/27,300BTU/h

H

8.50kW/29,000BTU/h

H

9.00kW/30,700BTU/h

For ASTA30/34


FG0050_RETAIL08.qxd

27/8/08

1:11 PM

Page 11

Easy maintenance

Inner drying operation

Since the front panel is easy to remove, maintenance is

This model is equipped with an inner drying function. After the power is

also easy.

turned off, the drying operation starts inside the air conditioner. This helps prevent the growth of mould and bacteria inside the indoor unit. During dew condensation

ASTA07/09/12/18LC

Approx. 20 mins Drying

ASTA24/30LC

The following features apply to ASTA24LC model

All DC High efficiency layout Large air flow and quiet operation by new air flow path B

Heat exchange capacities 20% up compared to conventional models

A

DC Fan Motor

B

V-PAM control

1

New 3-row heat exchange system

A

V-PAM technology makes a compressor more powerful. C

2

DC scroll compressor C

More compact compared with conventional model

3 Back view

Front view

Dirty Air

Air conditioner filter features

Apple-catechin filter

Ion deodorisation filter

Apple-catechin filter Fine dust, invisible mould spores and harmful micro organisms are absorbed onto the filter by static electricity and further growth is inhibited and deactivated by the polyphenol ingredient extracted from apples.

Long-life* Ion deodorisation filter The filter deodorises by powerfully decomposing absorbed odours using the oxidising filter and reducing effects of ions generated by the ultra-fine-particle ceramic. (*The filter can be used for approximately 3 years if it is washed under water to restore its surface action when it is dirty.)

Compact design

Conventional model

Clean Air

Deodorising (odour reduction rate) Deodorizing effect effect (Odour reduction rate) Ammonia (ppm) 160 120 80 40 0 0

With no filter

New filter 30

60

120 (min)

Trimethylamine (ppm) 160 120 80 40 0 0 30

New filter 60

120 (min)

Hydrogen sulfate (ppm) 160 With no filter 120 80 New filter 40 0 0 30 60 120 (min)

Testing organization : Environmental Sanitary Inspection Center Test method : Deodorization Test Testing organisation : Environmental Sanitary Inspection Center Test method : Deodorisation Test

New model

70kg

Unit: mm H320 x W1,120 x D220

With no filter

44kg

H900 x W900 x D350

H320 x W998 x D228

H578 x W790 x D315

11


FG0050_RETAIL08.qxd

27/8/08

1:11 PM

Page 12

Cassette

INVERTER

Wired type (with weekly/setback timer)

AUTA18L/24L

For AUTA18/24L AUT30L

AUTA18LAL

AUTA24LAL

AUT30L

C

5.20kW/17,700BTU/h

C

7.10kW/24,200BTU/h

C

8.50kW/29,000BTU/h

H

6.00kW/20,500BTU/h

H

8.00kW/27,300BTU/h

H

10.0kW/34,100BTU/h

Compact size (AUTA18L/24L)

Easy maintenance (AUT30L)

Compact grille fits common ceiling panel (590 x 590mm).

The control box is easily accessible for maintenance work. Wide opening for easy access. Detachable, washable filter and intake grille. Wide opening and long-life filter. High efficiency, long-life filter extends the cleaning cycle.

For AUT30L

Long-life filter

Long life filter

590

Duct connection (For AUT30L only) 590

Conditioned air can be distributed by means of a distribution duct.

(Unit: mm)

AUT30L Wired Remote Controller with Thermo Sensor • Room temperature sensor selection • Temperature SET BACK timer • Group control system • Child-proof lock • Dual remote controllers <optional> • Hot start <for heating>

INVERTER

One-way AUT30L

Fresh air Fresh air

Distribution Distributionduct duct

One-way

Fresh air can Fresh air can bebe introduced introduced through thisthis through opening.opening

Distribution Distribution duct duct

Two-way

Condensate pump Condensate pump lift to 400mm (AUTA18L/24L), 800mm (AUT30L)

Two-way AUT30L

Universal Floor/Ceiling The Inverter Universal Floor/Ceiling single room split system units are highly efficient.

For ABTA18L

ABTA18LAT

ABTA24LAT

C

5.20kW/17,700BTU/h

C

7.10kW/24,200BTU/h

H

6.00kW/20,500BTU/h

H

8.00kW/27,300BTU/h For ABTA24L

ABTA30LBT*

12

C

8.5kW/29000BTU/h

H

10.0kW/34100BTU/h *Ceiling type only

For ABTA30LBT


FG0050_RETAIL08.qxd

27/8/08

1:11 PM

Page 13

2 Room/4 Room

INVERTER

Multi System

The New Fujitsu Inverter Multi System is ideal where an individual indoor unit is required in each room, i.e., a living room and 3 bedrooms. The Multi Systems allow one outdoor unit to be connected up to a wide variety of 2, 3 or 4 indoor units including Wall Mounted, Floor/Ceiling Console and Cassette, depending on the model.

DC Inverter Multi Type System (The illustration below is an example of the AOT30LMAW4) This inverter system is equipped with a state of the art DC twin rotary compressor. It can reach the room temperature you set 15% quicker than conventional models and precisely maintain it at a difference of just 0.5째C. Advanced DC twin rotary compressor makes operation at high power and high efficiency a reality.

Select any type of indoor unit you like to suit the conditions of your room

Example illustration of system configuration

Compact Design

Easy installation and easy maintenance

Outdoor unit: AOT30LMAW4

Outdoor unit: AOT24LMAM2. Maintenance has been improved by making attachment and detachment of the top panel easy.

H835 x W900 x D330mm

d l

Current model

New model

Existing model

N

M d l

New model 13


FG0050_RETAIL08.qxd

27/8/08

1:11 PM

Page 14

ABT14/18/24LB

ASTA07/09/12/18LACM

AST24LB

Universal Type

Wall Mounted Type

Wall Mounted Type

AOT24LMAM2 C

5.80kW/19,800BTU/h

AUT12/14/18LB

H

6.40kW/21,900BTU/h

Cassette (Compact) Type

AOT30LMAW4 C

8.00kW/27,300BTU/h

H

9.60kW/32,800BTU/h

AUT12L/14L/18L ABT14L/18L/24L ASTA07L/09L/12L/18L AST24LBAJ

AOT24LM2 AOT30LM4

1 outdoor unit to 2 indoor units The total capacity of the indoor units that can be connected is 4.4 - 8.7kW(15,000 - 30,000BTU)

1 outdoor unit to 3â&#x20AC;&#x201C;4 indoor units The total capacity of the indoor units that can be connected is 7.9 - 14.3kW(27,000 - 49,000BTU)

Cassette type (Compact)

Floor/Ceiling Universal type

ASTA07LACM

2.3kW (7,900BTU)

ASTA09LACM

2.7kW (9,200BTU)

ASTA12LACM

AUT12LB

3.5kW (11,900BTU)

AUT14LB

ABT14LB

AUTA18LAL

ABTA18LAT

4.2kW (14,300BTU)

ASTA18LACM

5.2kW (17,800BTU)

6.3kW (21,500BTU)

AST24LB

ABTA24LAT

6.8kW (23,200BTU)

Refer to dealer for selection chart.

14

AOT 24 L M 2

Wall Mounted type (Large Size)

AOT 30 L M 4

Wall Mounted type (Small Size)


FG0050_RETAIL08.qxd

27/8/08

1:11 PM

Page 15

DC Twin Rotary Compressor

Independent Control

The Fujitsu Inverter System is equipped with

Each indoor unit can be operated independently. That is,

a state of the art DC twin rotary compressor.

on/off, temperature, air movement and time clock operation

It can reach the room temperature you set

can all be controlled from their own wireless remote.

15%* quicker than conventional models and precisely maintain it at a difference of just 0.5째C. Advanced DC twin rotary compressor

DC twin rotary compressor

makes operation at high power and high

Stable and Comfort

efficiency a reality.

Comparison of cooling efficiency of Comparison cooling efficiency of DC compressor DC ofcompressor (against AC compressor) (against AC compressor) Compressor COP

The air conditioner's output is stabilised at the optimum setting within the range from maximum to minimum to match the load, which is affected by factors such as the

100

room temperature and the number of people present. 90 COP (%)

DC Twin Rotary AC Twin Rotaly

80

2

4

6

8

10

12

Cooling Capacity(kW)

*Depends on room size and heat load.

High Energy Efficiency The high efficiency DC Inverter Multi System offers energy saving operation and approximately 50% higher efficiency than a constant-speed multi system. Improved Inverter cooling ratio prevents a drop in capacity when operating under load conditions.

CONVENTIONAL

50%

Energy savings over 1 year

Off

Approx. DC Inver DC Inverter Multi System

Constant

Constant-Speed Multi System

2 Room Multi System

AOT19F (AST9FMBD x2) C

2.90kW/9,900BTU/h

AOT19U (AST9UMBD x2)

AOT19F AOT19U

C

2.85kW/9,700BTU/h

H

3.25kW/11,100BTU/h

15


FG0050_RETAIL08.qxd

27/8/08

1:11 PM

Page 16

SPECIFICATIONS

INVERTER

NOCRIA Indoor Unit Outdoor Unit

Model No. Reverse Cycle System

Watts BTU/h Watts BTU/h Watts BTU/h Watts BTU/h Volts Ph - Hz

Cooling Capacity Range Heating Capacity Range Power Supply Phase-Frequency Power Supply Attachment Plug Size (If Applicable) Cooling Range Heating Range Cooling Range Heating Range

Running Current

Input

Moisture Removal E.E.R. C.O.P.

Cooling Heating Cooling Heating

Star Rating Fan Speeds Air Circulation Compressor Type

High

I.U. Dimensions and Weights O.U.

Height Width Depth Net Weight Height Width Depth Net Weight

I.U. Sound Pressure Level O.U. Sound Pressure Level O.U. Sound Power Level Refrigerant Connection Pipe Sizes

Gas Liquid

Pre Charged Length Minimum Pipe Length Maximum Pipe Length Maximum Pipe Height Pipe Connection Methods Outdoor operating Temp.

16

Amps Amps Amps Amps Amps Watts Watts Watts Watts l/hr

Cooling Heating

l/s mm mm mm kg mm mm mm kg dBA@1mtr dBA@1mtr dBA mm mm Metre Metre Metre Metre Degrees C Degrees C

PLASMA

AWTZ14LBC AOTZ14LBC Yes 4200 14300 900-5300 3100-18100 6000 20500 900-9100 3100-31000 240 1-50 Indoor 15 amp plug 4.3 Max 8.5 5.7 Max 14 1020 90-1750 1350 90-2950 2.1 4.12 4.44

INVERTER AWTZ18LBC AOTZ18LBC Yes 5200 17700 900-5900 3100-20100 6700 22900 900-9700 3100-33100 240 1-50 Indoor 15 amp plug 6.6 Max 8.5 6.9 Max 14 1580 90-2000 1630 90-3200 2.8 3.289 4.108

AWTZ24LBC AOTZ24LBT Yes 7400 25300 900-8000 3100-27300 8500 29000 900-10600 3100-36200 240 1-50 Outdoor NA 10.4 Max 12.5 9.9 Max 17.5 2460 110-2620 2350 110-3680 3 3.02 3.62

ASTB09LDC AOTS09LDC Yes 2600 8900 500-3700 1700-12600 3600 12300 500-6100 1700-20800 240 1-50 Indoor 10 amp plug 2.8 Max 6 3.7 Max 8.5 610 250-1380 810 250-1960 1.3 4.252 4.44

ASTB12LDC AOTS12LDC Yes 3500 11900 900-4300 3100-14700 4800 16400 900-6700 3100-22900 240 1-50 Indoor 15 amp plug 4.1 Max 7 5.3 Max 10 910 250-1610 1220 250-2300 1.8 3.843 3.934

INVERTER ASTB18LDC AOTS18LDC Yes 5200 17700 900-5700 3100-19400 6250 21300 900-9100 3100-31000 240 1-50 Indoor 15 amp plug 7.3 Max 9 7.4 Max 13.5 1720 90-2000 1730 90-2660 2.8 3.022 3.61

ASTB24LDC AOTS24LDC Yes 7400 25300 900-8000 3100-27300 8500 29000 900-10600 3100-36200 240 1-50 Outdoor NA 10.4 Max 12 10.2 Max 17.5 2460 110-2620 2420 110-3680 3 3.01 3.51

ASTB30LDC AOTS30LDT Yes 8100 27663 2900-9000 9900-30700 9200 31419 2200-11000 7500-37500 240 1-50 Outdoor NA 11.2 Max 18.5 11.4 Max 18.5 2660 580-4300 2700 500-4300 3 3.05 3.41

 

 

 

 

 

 

 

 

5 261 Rotary 250 899 298 13.5 578 790 300 39 46 47 65 R410A 12.7 6.35 15 3 20 15 Flare -10 to 43 -15 to 24

5 261 Rotary 250 899 298 13.5 578 790 300 39 46 48 65 R410A 12.7 6.35 15 3 20 15 Flare -10 to 43 -15 to 24

5 261 Scroll 250 899 298 14 830 900 330 62 47 53 68 R410A 15.88 6.35 15 3 30 20 Flare -10 to 43 -15 to 24

4 165 Rotary 283 790 230 9.5 540 790 290 34 40 48 65 R410A 9.52 6.35 15 3 20 15 Flare -10 to 43 -15 to 24

4 176 Rotary 283 790 230 9.5 540 790 290 36 41 49 67 R410A 9.52 6.35 15 3 20 15 Flare -10 to 43 -15 to 24

4 194 Rotary 283 790 230 9.5 578 790 300 40 42 50 68 R410A 12.7 6.35 15 3 20 15 Flare -10 to 43 -15 to 24

4 325 Scroll 320 998 228 14 578 790 315 44 47 53 69 R410A 15.88 6.35 15 3 30 20 Flare -10 to 43 -15 to 24

Type

4 325 Rotary 320 998 228 14 830 900 330 62 49 55 69 R410A 15.88 9.52 20 5 50 30 Flare -10 to 43 -15 to 24


27/8/08

1:11 PM

Room Size Chart

CEILING INSULATED WINDOW NOT FACING WEST

For future improvement, specifications & designs of product are subject to change without notice. Heating and cooling capacities are based on AS/NZS 3823. Cooling Indoor Temp: 27°C DB/19°C WB Outdoor Temp: 35°C DB Heating Indoor Temp: 20°C DB Outdoor Temp: 7°C DB /6°C WB

Small Window Minimum Large Window Minimum Small Window Maximum Large Window Maximum b k Please refer to disclaimers on back cover

8000 7000

6000

6000

Watts (W)

7000

5000 4000

5000 4000

3000

3000

2000

2000

1000

1000 0

10

15

20

25

30 35 40 Square Metres (M2)

45

50

55

60

65

70

0

CEILING INSULATED WINDOW FACING WEST

Watts (W)

Note: The appropriate load will vary according to the region. Use only as a guide.

CEILING UNINSULATED WINDOW NOT FACING WEST

8000

Watts (W)

Check your requirements

Page 17

10

15

20

25

30 35 40 Square Metres (M2)

45

50

55

60

65

70

65

70

CEILING UNINSULATED WINDOW FACING WEST

8000

8000

7000

7000

6000

6000

Watts (W)

FG0050_RETAIL08.qxd

5000 4000

5000 4000

3000

3000

2000

2000

1000

1000 0

10

15

20 S

25

ll Wi d

30 35 40 45 50 Square Metres (M2) Mi i S ll Wi d

55

60

65

70

0

10

15

M i

20 S

25

ll Wi d

30 35 40 45 50 Square Metres (M2) Mi i S ll Wi d

55

60

M i

WALL MOUNTED ASTA07JCC AOTR07JCC No 2100 7200 500-2800 1700-9600 240 1-50 Indoor 10 amp plug 2.7 Max 6 570 250-1140 1.0 3.68 -

ASTA09JCC AOTR09JCC No 2600 8900 500-3300 1700-11300 240 1-50 Indoor 10 amp plug 3.4 Max 6 740 250-1310 1.3 3.51 -

  4 149 Rotary 257 808 187 8 540 660 290 30 38 48 65 R410A 9.52 6.35 7.5 3 15 10 Flare 18 to 43 -

4 149 Rotary 257 808 187 8 540 660 290 30 38 48 65 R410A 9.52 6.35 7.5 3 15 10 Flare 18 to 43 -

ASTA12JCC AOTR12JCC No 3500 11900 900-4000 3100-13700 240 1-50 Indoor 10 amp plug 4.9 Max 7 1110 250-1410 1.8 3.15 -

ASTA18JCC AOTR18JCC No 5200 17700 900-6000 3100-20500 240 1-50 Outdoor NA 6.1 Max 9 1410 900-2000 2.8 3.69 -

  4 150 Rotary 275 790 215 8.5 540 790 290 36 38 49 67 R410A 9.52 6.35 7.5 3 15 10 Flare 18 to 43 -

4 250 Scroll 320 998 228 14 620 790 298 40 43 50 65 R410A 12.7 6.35 15 3 30 20 Flare 18 to 43 -

ASTA24JCC AOTR24JCC No 7100 24200 900-8000 3100-27300 240 1-50 Outdoor NA 9.4 Max 11.5 2210 110-2550 3 3.21 -

INVERTER ASTA30JCC ASTA34JCC AOTR30JCT AOTR34JCT No No 8000 9700 27300 33100 2900-9000 2900-10000 9900-30700 9900-34100 240 240 1-50 1-50 Outdoor Outdoor NA NA 11.2 16.4 Max 16.5 Max 18.5 2660 3900 580-3920 580-4400 3 4.5 3.01 2.49 -





4 306 Scroll 320 998 228 14 620 790 298 40 47 56 72 R410A 15.88 6.35 15 3 30 20 Flare 18 to 43 -

4 306 Rotary 320 998 228 14 830 900 330 58 49 53 69 R410A 15.88 9.52 20 3 30 20 Flare 18 to 43 -

 4 314 Rotary 320 998 228 14 830 900 330 58 50 54 70 R410A 15.88 9.52 20 3 30 20 Flare 18 to 43 -

ASTA09LCC AOTR09LCC Yes 2600 8900 500-3600 1700-12300 3600 12300 500-5300 1700-18100 240 1-50 Indoor 10 amp plug 3 Max 6 3.9 Max 8.5 655 250-1380 845 250-1960 1.3 3.963 4.261

ASTA12LCC AOTR12LCC Yes 3500 11900 900-4300 3100-14700 4800 16400 900-6700 3100-22900 240 1-50 Indoor 15 amp plug 4.1 Max 7 5.4 Max 10 920 250-1610 1240 250-2300 1.8 3.801 3.869

    4 165 Rotary 275 790 215 9 540 660 290 32 41 48 65 R410A 9.52 6.35 15 3 20 15 Flare 10 to 43 -15 to 24

4 176 Rotary 275 790 215 9 540 790 290 37 42 49 67 R410A 9.52 6.35 15 3 20 15 Flare 10 to 43 -15 to 24

ASTA18LCC AOTR18LCC Yes 5200 17700 900-5700 3100-19400 6250 21300 900-9100 3100-31000 240 1-50 Indoor 15 amp plug 7.3 Max 9 7.4 Max 13.5 1720 90-2000 1730 90-2660 2.8 3.022 3.61

ASTA24LCC AOTR24LCC Yes 7400 25300 900-8000 3100-27300 8500 29000 900-10600 3100-36200 240 1-50 Outdoor NA 10.4 Max 12 10.2 Max 17.5 2460 110-2620 2420 110-3680 3 3.011 3.516

ASTA30LCC AOTR30LCT Yes 8000 27300 2900-9000 9900-30700 9000 30700 2200-11000 7500-37500 240 1-50 Outdoor NA 11.7 Max 17 11.6 Max 19 2660 580-3600 2640 500-4300 3.4 2.989 3.385

 

 

 

4 194 Rotary 275 790 215 9 578 790 300 40 42 50 68 R410A 12.7 6.35 15 3 20 15 Flare -10 to 43 -15 to 24

4 305 Scroll 320 998 228 14 578 790 315 44 47 52 68 R410A 15.88 6.35 15 3 30 20 Flare -10 to 43 -15 to 24

4 305 Rotary 320 998 228 14 830 900 330 62 47 53 69 R410A 15.88 9.52 20 5 50 30 Flare -10 to 43 -15 to 24

17


FG0050_RETAIL08.qxd

27/8/08

1:11 PM

Page 18

MULTI SYSTEM 2/4 ROOM

INVERTER --

Type Indoor Unit Outdoor Unit

Model No. Reverse Cycle System

Watts BTU/h Watts BTU/h Watts BTU/h Watts BTU/h Volts Ph - Hz

Cooling Capacity Maximum Heating Capacity Maximum Power Supply Phase-Frequency Power Supply Attachment Plug Size (If Applicable) Cooling Range Heating Range Cooling Range Heating Range

Running Current

Input

Moisture Removal E.E.R. C.O.P.

Cooling Heating Cooling Heating

Star Rating Fan Speeds Air Circulation Compressor Type

High

I.U. Dimensions and Weights O.U.

Height Width Depth Net Weight Height Width Depth Net Weight

I.U. Sound Pressure Level O.U. Sound Pressure Level O.U. Sound Power Level Refrigerant Type Connection Pipe Sizes

Gas Liquid

Pre Charged Length Minimum Pipe Length Max. Pipe Length (per unit) Maximum Pipe Length Maximum Pipe Height Pipe Connection Methods Cooling Outdoor operating Temp. Heating

18

Amps Amps Amps Amps Watts Watts Watts Watts l/hr

l/s mm mm mm kg mm mm mm kg dBA@1mtr dBA@1mtr dBA mm mm Metre Metre Metre Metre Metre Degrees C Degrees C

ASTA07LACM Yes 2300 7900 1500-2700 5100-9200 2700 9200 1500-3300 5100-11300 240 1-50 Outdoor 0.8 4 139 275 790 215 9 35 R410A 9.52 6.35 25 10 Flare -

ASTA09LACM Yes 2700 9200 1500-3200 5100-10900 3300 11300 1500-4200 5100-14300 240 1-50 Outdoor 1 4 153 275 790 215 9 38 R410A 9.52 6.35 25 10 Flare -

WALL MOUNTED ASTA12LACM Yes 3500 11900 1500-3700 5100-12600 4000 13700 1500-4800 5100-16400 240 1-50 Outdoor 1.2 4 161 275 790 215 9 39 R410A 9.52 6.35 25 10 Flare -

ASTA18LACM Yes 5000 17100 1800-5600 6100-19100 6000 20500 1600-7100 5500-24200 240 1-50 Outdoor 2 4 183 275 790 215 9 45 R410A 12.7 6.35 25 10 Flare -

AST24LBAJ Yes 6800 23200 7400 25300 8200 28000 9000 30700 240 1-50 Outdoor 3 4 283 320 1120 220 16 47 R410A 15.88 9.52 25 10 Flare -

ABT14LBAJ Yes 4200 14300 5000 17200 4800 16400 5700 19500 240 1-50 Outdoor 1.5 3 177 199 990 655 28 36 R410A 12.7 6.35 25 10 Flare -

FLOOR/CEILING ABT18LBAJ Yes 5200 17800 6000 20500 6000 20500 7100 24200 240 1-50 Outdoor 1.7 3 216 199 990 655 28 43 R410A 12.7 6.35 25 10 Flare -

ABT24LBAJ Yes 6800 23200 7400 25300 8200 28000 9000 30700 240 1-50 Outdoor 2.5 3 244 199 990 655 28 48 R410A 15.88 9.52 25 10 Flare -

AUT12LBAB Yes 3500 11900 3800 13000 3800 13000 4500 15400 240 1-50 Outdoor 1.3 3 152 235 580 580 18 42 R410A 9.52 6.35 25 10 Flare -

CASSETT AUT14LBA Yes 4000 13700 4500 15400 4300 14700 5200 17800 240 1-50 Outdoo 1.5 3 152 235 580 580 18 42 R410A 12.7 6.35 25 10 Flare -


FG0050_RETAIL08.qxd

27/8/08

1:11 PM

OM

T12LBAB Yes 3500 11900 3800 3000 3800 3000 4500 15400 240 1-50 utdoor 1.3 3 152 235 580 580 18 42 R410A 9.52 6.35 25 10 Flare -

CASSETTE AUT14LBAB Yes 4000 13700 4500 15400 4300 14700 5200 17800 240 1-50 Outdoor 1.5 3 152 235 580 580 18 42 R410A 12.7 6.35 25 10 Flare -

Page 19

WALL MOUNTED MULTI

CASSETTE

CONVENTIONAL AST9FMBDx2 AST9UMBDx2 AOT19FSCV2 AOT19USCV2 No Yes 2900 2850 9900 9700 3250 11100 240 240 1-50 1-50 Outdoor Outdoor NA NA 4.7 4.6 NA NA 4.6 NA NA 1080 990 NA NA 1030 NA NA 1 1 2.69 2.83 3.16 4 4 144 130 Rotary Rotary 257 257 808 808 187 187 8 8 700 700 900 900 330 330 61 63 40 36 53 52 65 65 R410A R410A 9.52 9.52 6.35 6.35 7.5 7.5 5 5 NA NA 15 15 8 8 Flare Flare 18 to 43 10 to 43 -5 to 24

AUTA18LAL AOTA18LACL Yes 5200 17700 900-5900 3100-20100 6000 20500 900-7500 3100-25600 240 1-50 Outdoor NA 6.8 Max 9.0 7 Max 12.5 1620 90-2070 1660 90-2520 2.2 3.21 3.61

INVERTER AUTA24LAL AOTA24LACL Yes 7100 24200 900-8000 3100-27300 8000 27300 900-9100 3100-31000 240 1-50 Outdoor NA 9.3 Max 9.0 9.3 Max 13.5 2280 90-2610 2210 90-2800 2.7 3.11 3.61

AUT30LUAS AOT30LNAWL Yes 8500 29000 3000-10000 10200-34100 10000 34100 3000-11200 10200-38200 240 1-50 Outdoor NA 12 4.6-14.6 11.9 4.3-14.6 2860 1080-3500 2840 1000-3500 3 2.906 3.505

ABTA18LAT AOTA18LACL Yes 5200 17700 900-5900 3100-20100 6000 20500 900-7500 3100-25600 240 1-50 Outdoor NA 6.8 Max 8.6 7 Max 10.3 1620 Max 2040 1660 Max 2450 2 3.21 3.61

INVERTER ABTA24LAT AOTA24LACL Yes 7100 24200 900-8000 3100-27300 8000 27300 900-9100 3100-31000 240 1-50 Outdoor NA 9.3 Max 11.3 9.3 Max 11.6 2280 Max 2690 2210 Max 2760 2.7 3.11 3.61

 

 

 

 

    

4 188 Twin Rotary 245 (49) 570 (70) 570 (70) 15 (2.6) 578 790 300 40 38 50 65 R410A 12.7 6.35 15 3 NA 25 15 Flare -10 to 46 -15 to 24

4 258 Twin Rotary 245 (49) 570 (70) 570 (70) 17 (2.6) 578 790 315 44 49 52 68 R410A 15.88 6.35 15 3 NA 30 20 Flare -10 to 46 -15 to 24

3 444 Twin Rotary 296 830 830 37 830 900 330 64 48 55 68 R410A 15.88 9.52 15 5 NA 50 30 Flare -10 to 43 -10 to 24

4 216 Twin Rotary 199 990 655 27 578 790 300 40 44 50 65 R410A 12.7 6.35 15 3 NA 25 15 Flare -10 to 46 -15 to 24

4 277 Twin Rotary 199 990 655 27 578 790 315 44 49 52 68 R410A 15.88 6.35 15 3 NA 30 20 Flare -10 to 46 -15 to 24

OUTDOOR AUT18LBAB Yes 4300 14700 5200 17800 5000 17100 6300 21150 240 1-50 Outdoor 2 3 172 235 580 580 18 44 R410A 12.7 6.35 25 10 Flare -

AOT30LMAW4 AOT24LMAM2 Yes Yes 8000 5800 27300 19800 10100 7800 34500 26600 9600 6400 32800 21900 12000 9000 41000 30700 240 240 1-50 1-50 Outdoor Outdoor NA NA 9.3 7.3 Max 15.7 Max 12.2 10.1 6.9 Max 15.7 Max 12.2 2220 1730 Max 3580 Max 2920 2400 1640 Max 3580 Max 2920 3.6 3.35 4 3.9 916 805 Twin Rotary Twin Rotary 835 650 900 830 330 320 68 56 51 49 64 62 R410A R410A 2 x 9.52, 2 x 12.7 1 x 12.7, 1 x 9.52 4 x 6.35 2 x 6.35 50 30 5 5 25 20 Max Total 70 Max Total 30 10 10 Flare Flare 0 to 43 0 to 43 -10 to 24 -10 to 24

FLOOR/CEILING ABTA30LBT AOTA30LBTL Yes 8500 29000 2800-10000 9500-34100 10000 34100 2700-11200 9200-38200 240 1-50 Outdoor NA 11.6 Max 17.0 12.2 Max 17.0 2650 Max 3880 2710 Max 3880 2.5 3.21 3.69

4 461 Twin Rotary 240 1660 700 46 830 900 330 62 45 55 69 R410A 15.88 9.52 20 5 NA 50 30 Flare -15 to 46 -15 to 24

19


FG0050_RETAIL08.qxd

27/8/08

1:10 PM

Page 1

Products in this brochure contain R410A refrigerant. Please refer to specifications before installation & servicing this product.

Heating and cooling capacities are based on AS/NZS 3823.

Only persons and/or companies qualified and experienced in the installation, service and repair of refrigerant products should be permitted to do so. The purchaser must ensure that the person and/or company who is to install, service or repair this air conditioner has qualifications and experience in refrigerant products.

Cooling Indoor Temp: Outdoor Temp:

27°C DB/19°C WB 35°C DB

Heating Indoor Temp: Outdoor Temp:

20°C DB 7°C DB /6°C WB

Running current is at rated conditions (AS3823) and does not include compressor start-up or variations in power supply and load conditions.

Suitable access for warranty & service is required. For future improvement, specifications, designs of product and availability are subject to change without notice. Please check with your dealer.

N807 QAS is Accredited by the Joint Accreditation System of Australia and New Zealand, Acc No. S1250992AS

ISO 9002 Certified number: JQA-2005

All products specified in this brochure comply with the Australian Communications Authority’s (ACA) requirements for Electromagnetic Compatibility (EMC).

ISO 14001 Certified number: EC98J1137

Hamamatsu Fujitsu General Ltd.

AU S T R A L I A’ S FAVO U R I T E A I R

TM

FUJITSU GENERAL (AUST.) PTYABNLIMITED 55 001 229 554

Distributed by:

A Subsidiary of FUJITSU GENERAL LIMITED www.fujitsugeneral.com.au HEAD OFFICE NSW : 100 Holbeche Road Arndell Park N.S.W. 2148 TEL (02) 8822 2500 FAX (02) 8822 2501 VIC/TAS : Suite 1, Building 2, Omnico Business Centre, 270 Ferntree Gully Road, Notting Hill, VIC 3168

TEL (03) 9543 5899 FAX (03) 9543 8299

QLD

: 1 Breakfast Creek Road Newstead QLD 4006

TEL (07) 3257 2800 FAX (07) 3257 2184

SA/NT

: 146 Fullarton Road Rose Park S.A. 5067

TEL (08) 8364 0588 FAX (08) 8364 0591

WA

: Suite 3, 5 Mumford Place Balcatta W.A. 6021

TEL (08) 9240 5877 FAX (08) 9240 5866

E-mail: contact@fujitsugeneral.com.au – or call 1300 882 201 FG0050

PRINTED IN AUSTRALIA SPB 0609