Fujitsu Commercial Range

Page 1

air conditioning range Ducted Cassette Under Ceiling Multi Systems ERV’s


If it can be designed, we All over Australia, Fujitsu air conditioning is being installed in some of the most innovative and unusual building applications. That’s because our systems offer incredible design flexibility, smoother more efficient control and lower running costs.

So whether you need to air condition a few rooms or a few towers, Fujitsu has the solution. No wonder it’s Australia’s Favourite Air.

Features Up/down Swing Louvre

Sleep timer

control Port

The up/down louvre automatically swings up and down.

The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.

External inputs and outputs contained within the product allow on/off control, fresh air interlock connection and heater bank element connection. UTD-ECS5A* (optional parts)

right/Left Swing Louvre The right/left louvre automatically swings in either direction.

double Swing automatic Complex swing action of the louvres enables them to swing automatically in both horizontal and vertical directions.

automatic Louvre The position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.

auto Shut Louvre The auto shut louvres close or open automatically when the unit stops or starts.

automatic air Flow adjustment

Program timer This timer allows a number of on/off control options.

V-P M V-Pa

on-oFF timer

V-Pam Inverter technology increases the maximum output of the compressor significantly and enables high power and high efficiency.

ON-OFF timer can be set to operate once every 24 hours.

Weekly timer Different on-off times can be set for up to 7 days.

Weekly + Setback timer Weekly + Setback timer can set temperature for two time spans and for each day of the week.

Allows introduction of fresh air to occupied space.

Fresh air can be taken in by a fan which can be connected using UTD-ECS5A* (optional parts).

energy Saving Mode This mode raises the set temperature slightly in the cooling mode and lowers the set temperature in the heating mode to economically control the operation of the unit.

Filter sign Limits the maximum operation current, and performs operation with the power consumption suppressed. 1

ion

Washable Panel

Fresh air intake

economy Mode

Apple-catechin filter.

Conditioned air can be distributed to adjacent areas by means of a distribution duct.

auto restart

The unit automatically switches between heating and cooling modes based on the temperature setting and room temperature.

aF

Long-life Ion deodorisation filter.

connectable Fresh air duct

auto-changeover

I-Pam inverter technology enables high output and high efficiency performance.

connectable distributing duct

When auto mode is selected for the fan, the micro-processor adjusts the airflow to follow changes in room temperature.

Should there be temporary loss of power; the unit will automatically restart itself in the same operating mode, once the power is restored.

i-Pa -P M -Pa

Indicates the filter cleaning period by lamp.

2-3-4 Multi rooms Up to 4 units can be connected to 1 outdoor unit. Individual controls are available.

c cooling H Heating


can air condition it. contents About Ducted Systems

3

Inverter Ducted Technology

4

inverter type t Ducted

7

Cassette

11

Under Ceiling

12

Multi’s

15

ERV’s

20

“ With over 100 different brands of air conditioners on the market, how do you know you’re choosing the right one? Well, my advice is to go with a name you can trust, which is why I bought a Fujitsu. No other company can match their wide range, exceptional economy and superior efficiency. And with their famous 5 year parts and labour warranty, it’s no wonder Fujitsu is Australia’s Favourite Air.”

2


Ducted Air Conditioning the ultimate in air conditioning Ducted air conditioning is surely the ultimate in comfort. The Fujitsu ducted models offer quiet, efficient operation, are easy to maintain, and operate via a wall mounted LCD control that controls all functions of the system.

3

invisible comfort

the ducted air conditioning system

Whatever shape the room, ducted units create uniform temperatures throughout. The unit is totally concealed, usually within a ceiling void. Cool or warm air is then ducted into each room through outlets positioned in the walls, floor or ceiling. Easily controlled, Fujitsu’s ducted systems provide comfort throughout your house without leaving cool or hot spots.

• Perfect comfort throughout each room • Visually appealing • Concealed installation • Reverse cycle heating and cooling • Quiet operation • Easy-to-use LCD controller.


Inverter Ducted Technology What’s an inverter?

room warming speed

Through new, advanced technology, Inverter air conditioners are more economical to operate and quieter to run than conventional units. They can handle greater extremes in temperature, are smoother and more stable in operation and reach the desired temperature more quickly than conventional air conditioners. Power and speed inverter model

conventional model

Room Set Temp. Temp. Inverter

T/2

Conventional

T

Time

inverter control The Inverter component allows the outdoor unit to vary its speed and output to match the required capacity of the indoor unit. Thus, the Inverter model can achieve 30% more operating efficiency than conventional models and therefore, is much cheaper to run.

Stable & comfortable The air conditioner’s output is stabilised at the optimum setting within the range from maximum to minimum to match the load, which is affected by factors such as the room temperature and the number of people present.

all dc components By utilising a DC Compressor and Fan Motor, electricity loss is decreased and power consumption is substantially reduced. In addition, by increasing the air flow on high speed, the heat exchanger efficiency has been improved which has reduced the overall annual power consumption. outdoor unit dc Fan Motor

inverter control base

dc compressor

High efficiency dc twin rotary compressor A high performance, low noise, large capacity DC Twin Rotary Compressor is used for the large three phase ducted systems. The New DC Twin Rotary Compressor has a substantially increased refrigerant intake and compression efficiency which allows for an improvement in overall system energy efficiency.

4


5


Compact high static ducted features easy installation (compact size & light weight) Size & weight have been reduced making installation considerably easier.

current Model: 75kg

new Model: 50kg

Wire remote controller with cover

commercial mode By enabling the indoor unit’s internal controls, you can achieve a continual fan operation in the heating mode, as required for commercial installations.

operation sound (low noise)

child lock function

The new ducted models have increased airflow volume & decreased noise levels to 49dBA by adopting a plastic case, plastic fan and three airflow volume switch positions.

Simply pressing a combination of buttons on the standard wired remote controller, locks and unlocks the keypad, stopping accidental and unauthorised use.

temperature set back timer Simplified wired remote controller (optional)

SET BACK temperature NORMAL temperature

This controller can be used as an optional slave controller for dual comfort. It offers easier operation and backlit display.

Use this timer function to change the set temperature in the operation times set for each day of the week. This can be used together with other timer settings.

cobalt blue heat exchanger Hydrophillic coating Cobalt Blue protection Standard cromate protection Aluminium base material

room temperature sensor selection • Remote controller has remote sensor included. • User can select between remote controller sensor and/or return air sensor or remote sensor. Detecting point can be changed easily

Remote Sensor in the bedroom (effective at night)

The outdoor unit fins are coated with a blue corrosion resistant material to enhance durability and extend performance life of your air conditioner. Remote Controller in the living room (effective during the day)

advanced features (Utd-ecS5a required) 1. Fresh air output port. External fresh air fans can be connected to run in conjunction with the fan motor of the indoor unit.

group control One remote controller can control up to 16 air conditioners. All of the air conditioners will be operated with the same settings. example of ducted system configuration 2. Electrical heater output port. An External Electrical heater can be set to operate in conjunction with the heating cycle.

Connectable quantity: Maximum 16 indoor units for 1 remote controller Wired remote controller

dual remote controllers (optional) 3. External input port. Start/stop of the air conditioner can be controlled from external equipment. Some functions require commissioning at the time of installation to operate.

An additional controller can be added up to the maximum of two remote controllers. Either remote controller can control the air conditioner. However, the timer functions cannot be used at the slave unit.

6


inVerter dUcted inverter ducted Split Systems – High Static

inverter ducted Split System – Bulkhead type artF18L C H

artc30L

5.2 kW / 17,700 BTU/h 6.0 kW / 20,500 BTU/h

C H

Wired r.c

C H

7.10 kW / 24,200 BTU/h 8.00 kW / 27,300 BTU/h

arta30L C H

8.50 kW / 29,000 BTU/h 10.0 kW / 34,100 BTU/h

H

H

12.5 kW / 42,700 BTU/h 14.0 kW / 47,800 BTU/h

For artF18L

arta45L

10.0 kW / 34,100 BTU/h 11.2 kW / 38,200 BTU/h

Wired r.c

C

For artc30L/art45L

inverter ducted Split Systems – High Static – 3 Phase

arta36L C

art45L

Wired type (with weekly/ setback timer)

inverter ducted Split Systems – Slimline type arta24L

8.80 kW / 30,000 BTU/h 10.0 kW / 34,100 BTU/h

C H

artc36L

neW

12.5 kW / 42,700 BTU/h 14.0 kW / 47,800 BTU/h

For arta24L

For arta30L

C H

10.0 kW / 34,100 BTU/h 11.2 kW / 38,200 BTU/h

artc45L C H

12.5 kW / 42,700 BTU/h 14.0 kW / 47,800 BTU/h

artc54L C H

artc60L

14.0 kW / 47,800 BTU/h 16.0 kW / 54,600 BTU/h

C H

15.0 kW / 51,200 BTU/h 18.0 kW / 61,400 BTU/h

Wired type (with weekly/ setback timer)

For arta36/45L (For single phase)

For artc36/45/54/60L

inverter ducted Split Systems – High Static – 3 Phase artc72L C H

20.3 kW / 69,300 BTU/h 22.6 kW / 77,100 BTU/h

artc90L C H

7

25.0 kW / 85,300 BTU/h 28.0 kW / 95,500 BTU/h

FOR SPECIFICATIONS PLEASE TURN OVERLEAF

Wired type (with weekly/ setback timer)

8


Features & Benefits

Slim Line ducted

control Features

easy maintenance

easy installation

Various remote controllers and sensors can be selected.

Structural improvement is attained by making the bottom panel two pieces, front and rear. The internal fan casing is also manufactured in two pieces, namely upper and lower. The maintenance of the motor and fan can be easily carried out by removing the rear panel and the lower part of the casing while leaving the main chassis installed.

Main work settings can be done easily from the remote controller at installation.

1

2

3

1. Wired Remote Controller with Thermo Sensor. • Room temperature sensor selection • WEEKLY timer • Temperature SET BACK timer • Group control system • Child lock • Dual remote controllers (optional parts) • AUTO restart • Energy saving • Auto changeover (for heating)

High Static ducted

Main work settings • High ceiling setting • Auto restart • Temperature adjustment when cooling/heating.

dc twin rotary compressor

dc Fan Motor

High performance DC twin rotary compressor maximizes efficiency from low speed to high speed operation.

High performance and high efficiency compact DC fan motor.

Sine wave dc inverter control High efficiency operation is realized by using a sine wave DC inverter control.

optional parts Flange (Round) :

UTD-RF204

Flange (Square) :

UTD-SF045T

Remote Sensor Unit: UTD-RS100 External Control Set: UTD-ECS5A

• Hot start (for heating).

Drain Pump Unit :

2. Simple Remote Controller (optional parts).

UTZ-PX1NBA

3. Remote Sensor (optional parts). See above for the case of rear suction type.

inverter ducted – Bulkhead / Slim type TYPE Model No. Reverse Cycle System

MODEL Indoor Unit Outdoor Unit

Watts BTU/h Watts BTU/h Watts BTU/h Watts BTU/h Volts Ph- Hz

Cooling Capacity Range Heating Capacity Range Power Supply Phase-Frequency Power Supply Attachment Plug Size (If Applicable) Running Current

Input Moisture Removal E.E.R. C.O.P. Star Rating Fan Speeds Air Circulation Compressor Type

Cooling Range Heating Range Cooling Range Heating Range l/hr Cooling Heating Cooling Heating Stage High I.U. mm

Dimensions and Weights

Net Weight O.U. mm Net Weight

I.U. Sound Pressure Level O.U. Sound Pressure Level O.U. Sound Power Level Refrigerant Type Gas Connection Pipe Sizes Liquid Pre Charged Length Minimum Pipe Length Maximum Pipe Length Maximum Pipe Height Pipe Connection Methods Cooling Outdoor operating Temp. Heating

9

UNITS

Amps Amps

Watts

l/s Height Width Depth kg Height Width Depth kg dBA@1metre dBA@1metre dBA mm Metre

Degrees C Degrees C

INVERTER ARTF18LALU ARTA24LATU ARTA30LBTU ARTA36LATU ARTA45LATU AOTA18LALL AOTA24LALL AOTA30LBTL AOTA36LBTL AOTA45LBTL Yes Yes Yes Yes Yes 5,200 7,100 8,500 10,000 12,500 17,700 24,200 29,000 34,100 42,700 900-5,900 900-8,000 2,800-10,000 3,800-11,200 4,000-14,000 31,00-20,100 3,100-27,300 95,00-34,100 13,000-38,200 13,700-47,800 6,000 8,000 10,000 11,200 14,000 20,500 27,300 34,100 38,200 47,800 900-7,500 900-9,100 2,700-11,200 4,000-14,000 4,200-16,200 3,100-25,600 3,100-31,000 9,200-38,200 13,700-47,800 14,300-55,300 240 240 240 240 240 1-50 1-50 1-50 1-50 1-50 Outdoor Outdoor Outdoor Outdoor Outdoor NA NA NA NA NA 6.8 9.3 11.6 13 16.3 Max 9.0 Max 11.5 Max 17 Max 19 Max 20 6.7 9.3 11.7 12.7 16.1 Max 12.5 Max 12.2 Max 17 Max 19 Max 20 1,620 2,280 2,650 3,110 3,890 Max 2,160 Max 2,970 Max 3,880 Max 4,540 Max 4,780 1,660 2,210 2,680 3,020 3,830 Max 2,960 Max 3,330 Max 3,880 Max 4,540 Max 4,780 2 2.5 2.5 3 3.5 3.21 3.11 3.21 3.21 3.21 3.61 3.61 3.73 3.71 3.66 5 4.5 4.5 5 5 5 5 5 5.5 5.5 4 4 4 4 4 228 306 541 561 625 Twin Rotary Twin Rotary Twin Rotary Twin Rotary Twin Rotary 217 270 270 270 270 953 1,135 1,135 1,135 1,135 595 700 700 700 700 23 38 40 41 41 578 578 830 1290 1290 790 790 900 900 900 300 315 330 330 330 40 44 62 98 98 33 31 42 42 44 50 53 53 55 56 65 68 69 69 70 R410A R410A R410A R410A R410A 12.7 15.88 15.88 15.88 15.88 6.35 6.35 9.52 9.52 9.52 15 15 20 20 20 3 3 3 3 3 25 30 50 50 50 15 20 30 30 30 Flare Flare Flare Flare Flare -10 to 46 -10 to 46 -15 to 46 -15 to 46 -15 to 46 -15 to 24 -15 to 24 -15 to 24 -15 to 24 -15 to 24

inverter ducted – High Static TYPE Model No. Reverse Cycle System

MODEL Indoor Unit Outdoor Unit

Watts BTU/h Watts BTU/h Watts BTU/h Watts BTU/h Volts Ph- Hz

Cooling Capacity Range Heating Capacity Range Power Supply Phase-Frequency Power Supply Attachment Plug Size (If Applicable) Running Current

Input Moisture Removal E.E.R. C.O.P. Star Rating Fan Speeds Air Circulation Compressor Type

Cooling Range Heating Range Cooling Range Heating Range l/hr Cooling Heating Cooling Heating Stage High I.U. mm

Dimensions and Weights

UNITS

Net Weight O.U. mm Net Weight

I.U. Sound Pressure Level O.U. Sound Pressure Level O.U. Sound Power Level Refrigerant Type Gas Connection Pipe Sizes Liquid Pre Charged Length Minimum Pipe Length Maximum Pipe Length Maximum Pipe Height Pipe Connection Methods Cooling Outdoor operating Temp. Heating

Amps Amps

Watts

l/s Height Width Depth kg Height Width Depth kg dBA@1metre dBA@1metre dBA mm Metre

Degrees C Degrees C

INVERTER ARTC30LATU ART45LUAK AOTA30LCTL AOT45LJBYL Yes Yes 8,800 12,500 30,000 42,700 4,700-10,000 3,600-14,000 16,000-34,100 12,300-47,800 10,000 14,000 34,100 47,800 5,000-11,200 4,700-18,000 17,100-38,200 12,300-47,800 240 240 1-50 1-50 Outdoor Outdoor NA NA 11.3 18.1 Max 18.5 7.1-21.7 11.1 16 Max 18.5 6.3-20.1 2,700 4,300 Max 4,380 1,700-5,200 2,640 3,800 Max 4,380 1,500-4,800 1.0 3.0 3.26 2.91 3.79 3.68 5 4 5.5 5.5 3 3 694@100Pa 972@100pa Twin Rotary DC Scroll 400 400 1,050 1,050 500 500 42 50 1,290 1,290 900 900 330 330 98 105 43 49 52 54 68 65 R410A R410A 15.88 15.88 9.52 9.52 20 20 5 5 50 50 30 30 Flare Flare -15 to 46 0 to 43 -15 to 24 -10 to 21

inverter ducted – High Static – 3 Phase TYPE Model No. Reverse Cycle System

MODEL Indoor Unit Outdoor Unit

Watts BTU/h Watts BTU/h Watts BTU/h Watts BTU/h Volts Ph- Hz

Cooling Capacity Range Heating Capacity Range Power Supply Phase-Frequency Power Supply Attachment Plug Size (If Applicable) Running Current

Input Moisture Removal E.E.R. C.O.P. Star Rating Fan Speeds Air Circulation Compressor Type

Cooling Range Heating Range Cooling Range Heating Range l/hr Cooling Heating Cooling Heating Stage High I.U. mm

Dimensions and Weights

UNITS

Net Weight O.U. mm

Net Weight I.U. Sound Pressure Level O.U. Sound Pressure Level O.U. Sound Power Level Refrigerant Type Gas Connection Pipe Sizes Liquid Pre Charged Length Minimum Pipe Length Maximum Pipe Length Maximum Pipe Height Pipe Connection Methods Cooling Outdoor operating Temp. Heating

Amps Amps

Watts

l/s Height Width Depth kg Height Width Depth kg dBA@1metre dBA@1metre dBA mm Metre

egrees C Degrees Degrees C

ARTC36LCTU AOTD36LATT Yes 10,000 34,100 4,700-11,400 16,000-38,900 11,200 38,200 5,000-14,000 17,000-47,800 415 3-50 Outdoor NA 4.4 Max 10.0 4.2 Max 10.0 3,090 Max 5,460 2,940 Max 5,460 1.5 3.24 3.81 NA NA 3 700 DC Twin Rotary 400 1,050 500 42 1,290 900 330 107 45 53 67 R410A 15.88 9.52 30 5 75 30 Flare -15 to 46 -15 to 24

ARTC45LCTU AOTD45LATT Yes 12,500 42,700 5,400-14,000 18,400-47,800 14,000 47,800 5,800-16,200 19,800-55,300 415 3-50 Outdoor NA 5.8 Max 11.0 5.2 Max 11.0 4,060 Max 6,140 3,670 Max 6,140 1.5 3.08 3.81 NA NA 3 938 DC Twin Rotary 400 1,050 500 46 1,290 900 330 107 47 54 68 R410A 15.88 9.52 30 5 75 30 Flare -15 to 46 -15 to 24

INVERTER ARTC54LCTU ARTC60LCTU AOTD54LBTT AOTD60LATT Yes Yes 14,000 15,000 47,800 51,200 6,000-16,000 6,000-17,500 20,500-54,600 20,500-59,700 16,000 18,000 54,600 61,400 6,400-18,000 6,400-20,000 21,800-61,500 21,800-68,200 415 415 3-50 3-50 Outdoor Outdoor NA NA 6.7 7.5 Max 12.0 Max 12.0 6.2 7.5 Max 12.0 Max 12.0 4,750 5,320 Max 7,080 Max 6,830 4,370 5,280 Max 7,080 Max 6,830 2.5 3.0 2.95 2.82 3.66 3.41 NA NA NA NA 3 3 958 966 DC Twin Rotary DC Twin Rotary 400 400 1,050 1,050 500 500 46 46 1,290 1,290 900 900 330 330 107 107 47 47 55 56 70 71 R410A R410A 15.88 15.88 9.52 9.52 30 30 5 5 75 75 30 30 Flare Flare -15 to 46 -15 to 46 -15 to 24 -15 to 24

ARTC72LATU AOTA72LALT Yes 20,300 69,300 10,800-23,500 36,800-80,200 22,600 77,100 12,000-26,500 40,900-90,400 415 3-50 Outdoor NA 9.3 Max 22.8 9.3 Max 22.8 6,250 Max 10,100 6,270 Max 10,100 4.5 3.25 3.60 NA NA 3 1,190 DC Twin Rotary 450 1,587 825 100 1,690 930 765 215 47 57 75 R410A 25.4 12.7 20 5 75 30 Brazed -5 to 46 -15 to 24

ARTC90LATU AOTA90LALT Yes 25,000 85,300 11,200-28,000 38,200-95,500 28,000 95,500 12,500-31,500 42,600-107,500 415 3-50 Outdoor NA 11.5 Max 25.8 12.1 Max 25.8 7,820 Max 12,500 8,240 Max 12,500 6.0 3.20 3.40 NA NA 3 1,340 DC Twin Rotary 550 1,587 825 110 1,690 930 765 215 49 58 78 R410A 25.4 12.7 20 5 75 30 Brazed -5 to 46 -15 to 24

10


inVerter caSSette

inVerter Under ceiLing inverter dual console Split Systems – Floor/ceiling

inverter cassette Split Systems – compact aUtF18L C H

5.20 kW / 17,700 BTU/h 6.00 kW / 20,500 BTU/h

aUta24L C H

aBtF18L

7.10 kW / 24,200 BTU/h 8.00 kW / 27,300 BTU/h

C H

5.20 kW / 17,700 BTU/h 6.00 kW / 20,500 BTU/h

aBtF24L 7.10 kW / 24,200 BTU/h 8.00 kW / 27,300 BTU/h

C H

Provide wide air flow & quiet operation. optional

Wired r.c

Wireless r.c

optional

For aUtF18/aUta24L

Wired r.c

Wireless r.c

For aBtF18/24L

grille is an option.

inverter cassette Split Systems aUta30L C H

8.50 kW / 29,000 BTU/h 10.0 kW / 34,100 BTU/h

aUta36L C H

neW

10.0 kW / 34,100 BTU/h 11.2 kW / 38,200 BTU/h

inverter Under ceiling Split Systems aBta30L

aUta45L C H

12.5 kW / 42,700 BTU/h 14.0 kW / 47,800 BTU/h

C H

8.50 kW / 29,000 BTU/h 10.0 kW / 34,100 BTU/h

aBta36L C H

10.0 kW / 34,100 BTU/h 11.2 kW / 38,200 BTU/h

aBta45L C H

12.5 kW / 42,700 BTU/h 14.0 kW / 47,800 BTU/h

Provide wide air flow & quiet operation. optional optional

Wired r.c

ir receiver Kit

For aUta30

For aUta36/45L

Wireless r.c

grille is an option.

inverter Under ceiling Split System – 3 Phase aBta54L

aUta54L H

For aBta36/45L (For single phase)

Under ceiling installation only.

inverter cassette Split System – 3 Phase C

For aBta30L

Wired r.c

14.0 kW / 47,800 BTU/h 16.0 kW / 54,600 BTU/h

C H

14.0 kW / 47,800 BTU/h 16.0 kW / 54,600 BTU/h

Provide wide air flow & quiet operation. optional

optional

Wired r.c

ir receiver Kit

aUta54L (For 3 Phase)

Wireless r.c

aBta54L (For 3 phase)

Under ceiling installation only.

grille is an option.

11

Wired r.c

FOR SPECIFICATIONS PLEASE TURN OVERLEAF

12


Features & Benefits – inverter cassette

Features & Benefits – inverter Under ceiling improved installation/maintenance

High efficiency turbo fan with 3-dimensional blade Previous turbo fan: Air passing through the heat exchanger was uneven and the air would only flow close to the ceiling.

New turbo fan: High efficiency airflow distribution has been achieved by the introduction of a 3-dimensional blade which increases the air passing over the heat exchanger. 500mm

450mm Separation phenomenon of airflow causes noise

Wind velocity

Heat exchanger < Motor side >

Fast

Service port is provided at the high pressure side of the refrigerant circuit. The operation of the air conditioning refrigeration system can be checked by connecting a pressure gauge, etc. and installation and maintenance work is improved.

The new outdoor unit is equipped with handles at the front and back at about the same height as the left and right so that the unit can be easily carried during installation, etc.

The outdoor unit’s fan shape (large metal plate integrated bell mouth) reduces the air flow resistance and lowers noise levels (external fan guard) so units are less obtrusive to neighbours.

Setting by wired remote controller.

Heat exchanger < Motor side >

Conventional blade

Uneven airflow

improved handling during installation

Quiet

No airflow separation

Low noise realised

check joint standard equipment

3-dimensional blade Slow : Spin direction

: Airflow direction

inverter cassette TYPE Model No. Reverse Cycle System

Range

Range

Running Current

Input Moisture Removal E.E.R. C.O.P. Star Rating Fan Speeds Air Circulation Compressor Type

Cooling Range Heating Range Cooling Range Heating Range Cooling Heating Cooling Heating High I.U.(Grill)mm

Dimensions and Weights

Net Weight O.U. mm

I.U. Sound Pressure Level O.U. Sound Pressure Level O.U. Sound Power Level Refrigerant Connection Pipe Sizes Pre Charged Length Minimum Pipe Length Maximum Pipe Length Maximum Pipe Height Pipe Connection Methods Outdoor operating Temp.

13

UNITS

Watts BTU/h Watts BTU/h Watts BTU/h Watts BTU/h Volts Ph- Hz

Heating Capacity

Power Supply Phase-Frequency Power Supply Attachment Plug Size (If Applicable)

inverter Under ceiling

MODEL Indoor Unit Outdoor Unit

Cooling Capacity

Net Weight

Type Gas Liquid

Amps Amps

Watts l/hr

l/s Height Width Depth kg Height Width Depth kg dBA@1metre dBA@1metre dBA mm Metre

Cooling Heating

(Optional parts)

: Turbulent flow noise

Degrees C Degrees C

AUTF18LAL AOTA18LALL Yes 5,200 17,700 900-5,900 3,100-20,100 6,000 20,500 900-7,500 3,100-25,600 240 1-50 Outdoor NA 6.8 Max 12.0 7 Max 12.5 1,620 90-2,070 1,660 90-2,520 2.2 3.21 3.61 5 5 4 188 Twin Rotary 245(49) 570(700) 570(700) 15(2.6) 578 790 300 40 38 50 65 R410A 12.7 6.35 15 3 25 15 Flare -10 to 46 -15 to 24

AUTA24LBL AOTA24LALL Yes 7,100 24,200 900-8,000 31,00-27,300 8,000 27,300 900-9,100 31,00-31,000 240 1-50 Outdoor NA 9.3 Max 12.0 9.3 Max 13.5 2,280 90-2,610 2,210 90-2,800 2.7 3.11 3.61 4.5 5 4 258 Twin Rotary 245(49) 570(700) 570(700) 17(2.6) 578 790 315 44 49 52 68 R410A 15.88 6.35 15 3 30 20 Flare -10 to 46 -15 to 24

INVERTER AUTA30LBLU AUTA36LCLU AOTA30LBTL AOTA36LBTL Yes Yes 8,500 10,000 29,000 34,100 2,800-10,000 3,500-11,200 9,500-34,100 13,000-47,800 10,000 11,200 34,100 38,200 2,700-11,200 4,000-14,000 9,200-38,200 13,700-47,800 240 240 1-50 1-50 Outdoor Outdoor NA NA 11.1 12.3 Max 17.0 Max 19.0 11.6 12.5 Max 17.0 Max 19.0 2,650 2,940 Max 4,040 Max 4,540 2,770 2,980 Max 4,040 Max 4,540 2.5 3 3.21 3.4 3.61 3.76 5 5.5 5 5.5 4 4 444 500 Twin Rotary Twin Rotary 288(50) 288(50) 840(950) 840(950) 840(950) 840(950) 26(5.5) 26(5.5) 830 1,290 900 900 330 330 62 98 40 44 53 54 69 69 R410A R410A 15.88 15.88 9.52 9.52 20 20 5 5 50 50 30 30 Flare Flare -15 to 46 -15 to 46 -15 to 24 -15 to 24

TYPE AUTA45LCLU AOTA45LBTL Yes 12,500 42,700 4,000-14,000 13,700-47,800 14,000 47,800 4,200-16,200 14,300-55,300 240 1-50 Outdoor NA 16.3 Max 20.0 16.1 Max 20.0 3,890 Max 4,780 3,830 Max 4,780 4.5 3.21 3.66 5 5.5 4 527 Twin Rotary 288(50) 840(950) 840(950) 26(5.5) 1,290 900 330 98 46 55 70 R410A 15.88 9.52 20 5 50 30 Flare -15 to 46 -15 to 24

AUTA54LCLU AOTD54LBTT Yes 14,000 47,800 5,400-16,000 18,400-54,600 16,000 54,600 5,800-18,000 19,800-61,400 415 3-50 Outdoor NA 6.2 Max 9.9 6.3 Max 9.9 4,360 Max 6,480 4,430 Max 6,480 5.0 3.21 3.61 NA NA 4 560 DC Twin Rotary 288(50) 840(950) 840(950) 27(5.5) 1,290 900 330 107 47 55 70 R410A 15.88 9.52 30 5 75 30 Flare -15 to 46 -15 to 24

Model No. Reverse Cycle System

MODEL Indoor Unit Outdoor Unit

Watts BTU/h Watts BTU/h Watts BTU/h Watts BTU/h Volts Ph- Hz

Cooling Capacity Range Heating Capacity Range Power Supply Phase-Frequency Power Supply Attachment Plug Size (If Applicable) Running Current

Input Moisture Removal E.E.R. C.O.P. Star Rating Fan Speeds Air Circulation Compressor Type

Cooling Range Heating Range Cooling Range Heating Range Cooling Heating Cooling Heating High I.U.(Grill)mm

Dimensions and Weights

Net Weight O.U. mm

I.U. Sound Pressure Level O.U. Sound Pressure Level O.U. Sound Power Level Refrigerant Connection Pipe Sizes Pre Charged Length Minimum Pipe Length Maximum Pipe Length Maximum Pipe Height Pipe Connection Methods Outdoor operating Temp.

UNITS

Net Weight

Type Gas Liquid

Amps Amps

Watts l/hr

l/s Height Width Depth kg Height Width Depth kg dBA@1metre dBA@1metre dBA mm Metre

Cooling Heating

Degrees C Degrees C

ABTF18LAT AOTA18LALL Yes 5,200 17,700 900-5,900 3,100-20,100 6,000 20,500 900-7,500 3,100-25,600 240 1-50 Outdoor NA 6.8 Max 8.6 7 Max 10.3 1,620 Max 2,040 1,660 Max 2,450 2 3.21 3.61 5 5 4 216 Twin Rotary 199 990 655 27 578 790 300 40 44 50 65 R410A 12.7 6.35 15 3 25 15 Flare -10 to 46 -15 to 24

ABTF24LAT AOTA24LALL Yes 7,100 24,200 900-8,000 3,100-27,300 8,000 27,300 900-9,100 3,100-31,000 240 1-50 Outdoor NA 9.3 Max 11.3 9.3 Max 11.6 2,280 Max 2,690 2,210 Max 2,760 2.7 3.11 3.61 4.5 5 4 277 Twin Rotary 199 990 655 27 578 790 315 44 49 52 68 R410A 15.88 6.35 15 3 30 20 Flare -10 to 46 -15 to 24

INVERTER ABTA30LBT ABTA36LAT AOTA30LBTL AOTA36LBTL Yes Yes 8,500 10,000 29,000 34,100 2,800-10,000 3,800-11,200 9,500-34,100 13,000-38,200 10,000 11,200 34,100 38,200 2,700-11,200 4,000-14,000 9,200-38,200 13,700-47,800 240 240 1-50 1-50 Outdoor Outdoor NA NA 11.6 13 Max 17.0 Max 19.0 12.2 12.7 Max 17.0 Max 19.0 2,650 3,110 Max 3,880 Max 4,540 2,710 3,020 Max 3,880 Max 4,540 2.5 3 3.21 3.21 3.69 3.71 5 5 5.5 5.5 4 4 461 527 Twin Rotary Twin Rotary 240 240 1,660 1,660 700 700 46 46 830 1,290 900 900 330 330 62 98 45 47 55 54 69 69 R410A R410A 15.88 15.88 9.52 9.52 20 30 5 5 50 50 30 30 Flare Flare -15 to 46 -10 to 46 -15 to 24 -15 to 24

ABTA45LAT AOTA45LBTL Yes 12,500 42,700 4,000-14,000 13,700-47,800 14,000 47,800 4,200-16,200 14,300-55,300 240 1-50 Outdoor NA 16.3 Max 20.0 16.1 Max 20.0 3,890 Max 4,780 3,830 Max 4,780 4.5 3.21 3.66 5 5.5 4 583 Twin Rotary 240 1,660 700 46 1,290 900 330 98 49 55 70 R410A 15.88 9.52 30 5 50 30 Flare -10 to 46 -15 to 24

ABTA54LCTU AOTD54LBTT Yes 14,000 47,800 5,400-16,000 18,400-54,600 16,000 54,600 5,800-18,000 19,800-61,400 415 3-50 Outdoor NA 6.6 Max 9.9 6.6 Max 9.9 4,650 Max 6,480 4,670 Max 6,480 5.0 3.01 3.43 NA NA 4 644 DC Twin Rotary 240 1,660 700 48 1,290 900 330 107 51 55 70 R410A 15.88 9.52 30 5 75 30 Flare -10 to 46 -15 to 24

14


MULti SySteMS

Multiple rooms comfortably

inverter Multi Systems The New Fujitsu Inverter Multi System is ideal for conditions that require an individual indoor unit in each room, i.e. a living room and 3 bedrooms. The Multi Systems allows one outdoor unit to be connected up to a wide variety of 3 or 4 indoor units including Wall Mounted, Floor/Ceiling Console, Cassette and Ducted.

• control several indoor units with one outdoor unit • Build the optimum system you desire.

indoor Unit FeatUreS

If you want to keep a large floor as well as many rooms comfortable, we recommend you use Multi Systems to build a simple system using one outdoor unit. Choose from a large lineup of air conditioner types that match your rooms. You can mix and match them at will. Build the system that is just right for you.

ASTA07/09/12/18L

AST24L

AUTF12/18L

Select any type of indoor unit you like to suit the conditions of your room

ABTF18/24L ARTF09/12/18/22L

• •

°

°

° ° •

° Optional function

indoor Unit

ASTA07/09/12/18L

kW

aot24LMaM2*

aot30LMaW4**

2.3

2.7

3.5

5.0

• •

6.8 AST24L

AUTF12/18L

ABTF18/24L

3.5

5.2

5.3

• •

6.4

2.7

ARTF09L

Example illustration of system configuration.

ARTF12/18/22L

3.5

5.2

6.3

Selection must only be made via capacity table charts available from Fujitsu. Refer to Dealer for a selection of combinations. *AOT24 : Model code combination should be between 14-30. **AOT30: Model code combination should be between 27-49.

aUtF12/18L cassette compact type

two and Four room Lineups Wired type

artF9L duct type (small)

Wired type

artF12/18/22L duct type

aot24LMaM2 C H

aBtF18/24L Universal type

C H

8.00 kW / 27,300 BTU/h 9.60 kW / 38,200 BTU/h

aSt24L Wall Mounted type

15

aSta7/9/12/18L Wall Mounted type

5.80 kW / 19,800 BTU/h 6.40 kW / 21,900 BTU/h

aot30LMaW4

FOR SPECIFICATIONS PLEASE TURN OVERLEAF

16


New Model H835 x W900 x D330 New Model Current Model H835 x W900 x D330

Current Model

Features & Benefits easy installation and easy maintenance

compact design Previous model

New model

Previous model

New model

High Efficiency DC Inverter Multi System permits energy saving operation and 40% higher efficiency than a Constant-Speed Multi System. Improved Inverter Cooling Ratio prevents decrease in capacity under overload operation. Energy saving over a year’s time

Existing Model

H835 x W900 x D330mm

energy saving Flexible installation Max.Piping Length (each Unit): 20m (AOT24LMAM2), 25m (AOT30LMAW4)

Max.Height: 10m (AOT24LMAM2 / AOT30LMAW4)

Existing Model

total Piping Length:

New Model

30m (AOT24LMAM2),

outdoor unit: AOT30LMAW4

New Model outdoor unit: AOT24LMAM2. Maintenance has been improved by making attachment and detachment of the top panel easy.

dc twin rotary compressor Efficiency is improved over a wide range from high-speed rotation at high load up to the low-speed rotation region at low-load where long-term use is especially frequent, and high power is produced with little power consumption. Also, twin rotor provides low-vibration and quiet operation.

70m (AOT30LMAW4)

Constant-Speed Multi Systems

DC Inverter Multi Systems

inverter Multi Systems Type Model No. Reverse Cycle System

Model Indoor Unit Outdoor Unit

Watts BTU/h Watts BTU/h Watts BTU/h Watts BTU/h Volts Ph- Hz

Cooling Capacity Range (Maximum for Inverter Multi) Heating Capacity Range(Maximum for Inverter Multi) Power Supply Phase-Frequency Power Supply Attachment Plug Size (If Applicable) Running Current

Input Moisture Removal E.E.R. C.O.P. Star Rating Fan Speeds Air Circulation Compressor Type

Cooling Range Heating Range Cooling Range Heating Range Cooling Heating Cooling Heating High

I.U. mm Dimensions and Weights

Net Weight O.U. mm

I.U. Sound Pressure Level O.U. Sound Pressure Level O.U. Sound Power Level Refrigerant Connection Pipe Sizes Pre Charged Length Minimum Pipe Length Maximum Pipe Length per unit Inverter Multi only Maximum Pipe Length Maximum Pipe Height Pipe Connection Methods Outdoor Operating Temp.

17

Units

Net Weight

Type Gas Liquid

Amps Amps

Watts l/hr

l/s Height Width Depth kg Height Width Depth kg dBA@1metre dBA@1metre dBA mm Metre Metre Metre Metre

Cooling Heating

Degrees C Degrees C

ASTA07LACM Yes 2,300 7,900 1,500-2,700 5,100-9,200 2,700 9,200 1,500-3,300 5,100-11,300 240 1-50 Outdoor 0.8 4 139 275 790 215 9 35 R410A 9.52 6.35 25 10 Flare -

ASTA09LACM Yes 2,700 9,200 1,500-3,200 5,100-10,900 3,300 11,300 1,500-4,200 5,100-14,300 240 1-50 Outdoor 1 4 153 275 790 215 9 38 R410A 9.52 6.35 25 10 Flare -

Wall Mounted ASTA12LACM Yes 3,500 11,900 1,500-3,700 5,100-12,600 4,000 13,700 1,500-4,800 5,100-16,400 240 1-50 Outdoor 1.2 4 161 275 790 215 9 39 R410A 9.52 6.35 25 10 Flare -

ASTA18LACM Yes 5,000 17,100 1,800-5,600 6,100-19,100 6,000 20,500 1,600-7,100 5,500-24,200 240 1-50 Outdoor 2 4 183 275 790 215 9 45 R410A 12.7 6.35 25 10 Flare -

AST24LBAJ Yes 6,800 23,200 7,400 25,300 8,200 28,000 9,000 30,700 240 1-50 Outdoor 3 4 283 320 1120 220 16 47 R410A 15.88 9.52 25 10 Flare -

Floor/Ceiling ABTF18LAT ABTF24LAT Yes Yes 5,200 6,800 17,800 23,200 1,800-6,100 1,800-7,400 6,100-20,800 6,100-25,300 6,000 8,200 20,500 28,000 1,600-7,100 1,600-9,000 5,500-24,200 5,500-30,700 240 240 1-50 1-50 Outdoor Outdoor 1.7 2.5 3 3 216 244 199 199 990 990 655 655 28 28 43 48 R410A R410A 12.7 15.88 6.35 6.35 25 25 10 10 Flare Flare -

Cassette AUTF12LAL AUTF18LAL Yes Yes 3,500 5,200 11,900 17,800 1,500-3,700 1,800-5,800 5,100-12,600 6,100-19,800 3,800 6,000 13,000 20,500 1,500-4,800 1,600-7,100 5,100-16,400 5,500-24,200 240 240 1-50 1-50 Outdoor Outdoor 1.3 2 3 3 152 172 235 235 580 580 580 580 18 18 42 44 R410A R410A 9.52 12.7 6.35 6.35 25 25 10 10 Flare Flare -

ARTF09LALU Yes 2,700 9,200 1,500-3,200 5,100-10,900 3,300 11,300 1,500-4,100 5,100-14,000 240 1-50 Outdoor 1 4 133 217 663 595 18 35 R410A 9.52 6.35 25 10 Flare -

Bulkhead ARTF12LALU ARTF18LALU Yes Yes 3,500 5,200 11,900 17,800 1,500-3,900 1,800-6,100 5,100-13,300 6,100-20,800 3,800 6,000 13,000 20,500 1,500-4,800 1,600-7,100 5,100-16,400 5,500-24,200 240 240 1-50 1-50 Outdoor Outdoor 1.2 1.7 4 4 175 236 217 217 953 953 595 595 23 23 30 34 R410A R410A 9.52 12.7 6.35 6.35 25 25 10 10 Flare Flare -

ARTF22LALU Yes 6,300 21,500 1,800-6,800 6,100-23,200 7,500 25,600 1,600-8,800 5,500-30,000 240 1-50 Outdoor 2.5 4 294 217 953 595 23 40 R410A 12.7 6.35 25 10 Flare -

Outdoor AOT30LMAW4 AOT24LMAM2 Yes Yes 8,000 5,800 27,300 19,800 10,100 7,800 34,500 26,600 9,600 6,400 38,200 21,900 12,000 9,000 41,000 30,700 240 240 1-50 1-50 Outdoor Outdoor NA NA 9.3 7.3 Max 15.7 Max 12.2 10.1 6.9 Max 15.7 Max 12.2 2,220 1,730 Max 3,580 Max 2,920 2,400 1,640 Max 3,580 Max 2,920 3.6 3.35 4 3.9 916 805 Twin Rotary Twin Rotary 835 650 900 830 330 320 68 56 51 49 64 62 R410A R410A 2 x 9.52, 2 x 12.7 1 x 12.7, 1 x 9.52 4 x 6.35 2 x 6.35 50 30 5 5 25 20 Max Total 70 Max Total 30 10 10 Flare Flare 0 to 43 0 to 43 -10 to 24 -10 to 24

18


energy recovery ventilator

Effective heat exchange and simultaneous fresh air ventilation High efficiency and low noise levels are achieved by using a highly efficient heat exchange process. A comfortable air conditioned environment is achieved by conveniently selecting whether to use heat exchange or normal ventilation setting, according to requirements of the conditioned space.

Energy saving ventilation

Humidity adjusting effect

Air conditioning operation can be reduced thanks to the efficient recovery of thermal energy lost during ventilation.

By efficient use of the heat transfer device within the ERV, fresh air humidity levels are balanced more effectively.

Load reduction

Sound shield effect

Load reduction within the conditioned space can be achieved as the heat exchanger effectively recovers cooled or heated room temperatures and simultaneously ventilates the air.

The ducts of the unit and the heat exchange element create a sound shield effect. This ensures that the working environment noise levels are preserved.

Heat exchange ventilation and normal ventilation Heat exchange ventilation

Normal ventilation

When a room is cooled or heated, the exhausted cooling / heating energy is recovered by heat-exchange ventilation.

This operation is used during periods when rooms require no cooling or heating effect. i.e. when there is minimal temperature difference between the indoor and outdoor environments.

Exhaust air

Energy Recovery Ventilator unit offers maximum comfort and greater energy savings

Energy Recovery Ventilator available in five sizes to suit most applications. UTZ-BX025A

UTZ-BX050A

UTZ-BX035A

UTZ-BX080A

UTZ-BD100A

Slim shape and easier installation Counter-flow heat exchange element used for reduced noise and slimmer, more compact body shape.

UTZ-BX080A/BD100A

UTZ-BX025A/BX035A/BX050A

Energy Recovery Ventilator

Outside air Rated Flow rate Model No.

69 L/Sec

97 L/Sec

138 L/Sec

222 L/Sec

277 L/Sec

UTZ-BX025A

UTZ-BX035A

UTZ-BX050A

UTZ-BX080A

UTZ-BD100A

Power Source

Room air

Supply air

Heat Exchange Ventilation

Adopts a highly efficient counter-flow heat exchange element.

High energy efficiency Energy consumption is dramatically reduced by using a counterflow heat-exchange element. Air conditioning load is reduced by approximately 20%, resulting in significant energy savings. Recovers up to 77% of the heat in the outgoing air.

More comfort Quiet operation Significantly reduces low pressure loss which allows a low noise operation of 32dBA or less on high fan operation(138 L/Sec model).

Normal Ventilation

Dimensions

220-240, 50Hz Input Power

(Extra High)/High/Low

W

119/99/79

154/124/117

214/169/151

347/309/302

445/360/332

Air Flow Rate

(Extra High)/High/Low

L/sec

69/69/47

97/97/77

138/138/102

222/222/180

277/277/225

External Static Pressure

(Extra High)/High/Low

Pa

90/80/37

95/65/42

105/70/38

140/110/70

90/55/35

Temperature Exchange Efficiency

(Extra High)/High/Low

%

75/75/77

75/75/77

75/75/77

75/75/76

75/75/76

Energy Exchange Efficiency Cooling

(Extra High)/High/Low

%

63/63/66

66/66/69

62/62/67

65/65/68

65/65/68

Energy Efficiency Exchage Heat Pump (Extra High)/High/Low

%

70/70/73

69/69/71

67/67/71

71/71/74

71/71/73

Sound Pressure Level

(Extra High)/High/Low

dB

28/26/21

32/29/25

34/31/25

38/36.5/32

37.5/36/31

Input Power

(Extra High)/High/Low

W

119/98/79

151/119/113

210/161/145

337/300/397

438/358/329

Air Flow Rate

(Extra High)/High/Low

L/sec

69/69/47

97/97/77

138/138/102

222/222/180

277/277/225

External Static Pressure

(Extra High)/High/Low

Pa

90/80/37

95/65/42

105/70/38

140/110/70

90/55/35

Sound Pressure Level

(Extra High)/High/Low

dB

27/26.5/21.5

31/30/26

34/32/26.5

38.5/37/33

38/36.5/31.5

HxWxD

mm

882 x 599 x 270 882 x 804 x 270 962 x 904 x 270 1,322 x 884 x 388 1,322 x 1,134 x 388

Weight

kg

29

37

43

71

83

Outlet Duct Diameter

mm

150

150

200

250

250

Operation Range

째C

-10 to 40

-10 to 40

-10 to 40

-10 to 40

-10 to 40

Maximum Humidity

%

85

85

85

85

85

* The noise level must be measured 1.5 m below the centre of the unit.

19

20


Products in this brochure contain R410A refrigerant. Please refer to specifications before installation & servicing this product.

All Capacity and energy efficiency ratings are based on AS/NZS 3823.2 Amendment 3 (2008).

Only persons and/or companies qualified and experienced in the installation, service and repair of refrigerant products should be permitted to do so. The purchaser must ensure that the person and/or company who is to install, service or repair this air conditioner has qualifications and experience in refrigerant products.

Cooling Indoor Temp: Outdoor Temp:

27°C DB/19°C WB 35°C DB

Heating Indoor Temp: Outdoor Temp:

20°C DB 7°C DB /6°C WB

Running current is at rated conditions (AS3823) and does not include compressor start-up or variations in power supply and load conditions.

Suitable access for warranty & service is required. For future improvement, specifications, designs of product and availability are subject to change without notice. Please check with your dealer.

N807 ISO 9002 Certified number: JQA-2005

All products specified in this brochure comply with the Australian Communications Authority’s (ACA) requirements for Electromagnetic Compatibility (EMC).

ISO 14001 Certified number: EC98J1137

Hamamatsu Fujitsu General Ltd.

A U S TRALIA ’S FAVOURITE AIR

TM

Distributed by:

FUJITSU GENERAL (AUST.) PTYABNLIMITED 55 001 229 554 A Subsidiary of FUJITSU GENERAL LIMITED www.fujitsugeneral.com.au

HEAD OFFICE NSW : Eastern Creek Drive, Eastern Creek N.S.W. 2766

TEL (02) 8822 2500 FAX (02) 8822 2501

VIC/TAS : Suite 1, Building 2, Omnico Business Centre, 270 Ferntree Gully Road, Notting Hill, VIC 3168

TEL (03) 9543 5899 FAX (03) 9543 8299

QLD

: 1 Breakfast Creek Road Newstead QLD 4006

TEL (07) 3257 2800 FAX (07) 3257 2184

SA/NT

: 146 Fullarton Road Rose Park S.A. 5067

TEL (08) 8364 0588 FAX (08) 8364 0591

WA

: Suite 3, 5 Mumford Place Balcatta W.A. 6021

TEL (08) 9240 5877 FAX (08) 9240 5866

E-mail: contact@fujitsugeneral.com.au – or call 1300 882 201 PRINTED IN AUSTRALIA TPB 01/10