Issuu on Google+

TOOD JOSEPH GRACI

ARC403 SENIOR DESIGN STUDIO FALL 2009


PRECEDENT STUDY: RUE DES SUISSES, HERZOG + de MEURON, PARIS 1996-200

URBAN FORM

RURAL FORM

-

COURTYARD

VEHICLE ACCESS

CONTRAST OF URBAN FORM VS. RURAL FORM UNDULATION IN PLAN AND SECTION ACTIVE FACADE INFILL BUILDINGS AND OBJECT BUILDING INTERIOR COURTYARD

PEDESTRIAN ACCESS / CIRCULATION


1A

2A

3A 1B

4A

2B

3B

4B

5B

5A 1C

1C

UNDULATION IN PLAN

A - URBAN APARTMENTS (SINGLE OR DOUBLE) B - RURAL APARTMENTS (FAMILY SIZE) C - RURAL COTAGES (INDIVIDUAL SECLUSION)

UNDULATION IN SECTION

1A

5A 6B 6A

7A 8A

7B

8B

9B

10B


SITE PLAN


CONCEPTUAL CORE DIAGRAM TYPICAL RESIDENTIAL TOWER

LIVING SPACES AROUND SERVICE SPACES (BEDROOMS, LIVING AREAS,)

DISSEMINATION OF THE BUILDING CORE

HORIZONTAL CIRCULATION (SKIP STOP)

SERVICE SPACES AROUND CORE (KITCHENS, BATHROOMS, UTILITY ROOMS)

VERTICAL CIRCULATION

BUILDING CORE VERTICAL CIRULATION VERTICAL SERVICES

NEW BUILDING CORE


BUILDING SPACES BREAKDOWN

SERVICE SPACES (KITCHEN, BATHROOMS, LIVING ROOMS)

LIVING SPACES (BEDROOMS, LIVING AREAS)

SERVICE SPACES AROUND HORIZONTAL CIRCULATION (SKIP STOP)

LIVING SPACES MOVE ABOVE OR BELOW SERVICE SPACES

NEW BUILDING CORE


PARKING / BASEMENT (-5’10”)

SCHEME DESIGN PLANS AND BUILDING SECTION

FITNESS CENTER / RESIDENTIAL LOBY GROUND FLOOR (+5’10”)


FITNESS CENTER / RESIDENTIAL LOBY FLOOR 2 (+17’6”)

BUILDING SECTION


FLOOR 3 - RESIDENTIAL (+29’2”)

SCHEME DESIGN PLANS AND BUILDING SECTION

FLOOR 4 - RESIDENTIAL (+40’10”)


FLOOR 5 - RESIDENTIAL (+52’6”)

BUILDING SECTION


UNIT PLANS AND AGGREGATION

STUDIO UNIT (580 SQ. FT.)

4 BEDROOM UNIT (2,100 SQ. FT.)

3 BEDROOM UNIT (1,900 SQ. FT.)

2 BEDROOM UNIT (1,400 SQ. FT.)


6 STUDIO UNITS

3 TWO BEDROOM UNITS 6 THREE BEDROOM UNITS 3 FOUR BEDROOM UNITS

3 TWO BEDROOM UNITS 3 THREE BEDROOM UNITS


SECTION / ELEVATION STUDY


Occupancy groups + means of egress Occupancy Group

R-2

Occupancy Load

Maximum oor area

(feet squared)

(feet squared)

Number of occupants

Number of egress staris

Stair Width

(feet squared)

(inches)

Smokeproof Staris

Sprinkelers

Maximum travel distance (feet)

200

2176

136

2

44

No

Yes

250

S-2

200

12000

60

NA

NA

NA

Yes

250

A-4

50

6800

136

2

44

No

Yes

75

A-5

50

6600

132

2

44

No

Yes

75

Parking Garages

Assembly, Indoor

Assembly, Outdoor

Area and Height LimitaƟons/Type of ConstrucƟon Occupancy Group

Fire RaƟng

Maximum oor area

Maximum height

Material

(feet squared)

R-2 S-2

Parking Garages

2 HR

57000

75 Ō

Reinforced Concrete

2 HR

UA

60

Reinforced Concrete

A-4

Unprotected

UA

75 Ō

Structural Steel

A-5

Unprotected

UA

UH

Reinforced Concrete

Assembly, Indoor

Assembly, Outdoor

NoncombusƟble

UH 12 11 10 9 8 7 6 5 4 3 2 1

Spr UH UH

3- Hour

2-Hour

1-Hour

Type I-A

Type I-B

Type II-A

Spr 60’

Spr 180’

Spr 60’

Unprotected Type II-B

Spr 85’

Spr 60’

Spr 70’

Spr 50’

216,000 216,000 216,000 144,000 96,000

96,000 72,000 48,000 24,000

144,000 144,000 144,000 96,000 64,000

64,000 48,000 32,000 16,000

72,000

24,000

48,000

16,000

UH

UH

UH

UH

UH

UH

UH

LIFE SAFETY: OCCUPANCY GROUPS AND FIRE RATED CONSTRUCTION

PARKING / BASEMENT (-5’10”)


BUILDING SECTION

FLOOR 4 - RESIDENTIAL (+40’10”)

2 HR FIRE RATED STRUCTURAL WALLS

1 HR FIRE RATED ROOF

2 HR FIRE RATED FLOORS

3 HR FIRE RATED PARKING STRUCTURE

1 HR FIRE RATED WALLS


RESIDENTIAL UNITS

PARKING / BASEMENT (-5’10”)

AREAS OF REFUGE

ESCAPE STAIRS

EGGRESS CORRIDOR (44” WIDTH)

FITNESS CENTER

FITNESS CENTER / RESIDENTIAL LOBY GROUND FLOOR (+5’10”)

RESIDENTIAL LOBY


FLOOR 4 - RESIDENTIAL (+40’10”)

LIFE SAFETY: MEANS OF EGRESS


PARKING / BASEBMENT LEVEL ACCESSIBILITY

FITNESS CENTER / RESIDENTIAL LOBY LEVEL ACCESSIBILITY

-Elevator 1 - 7’ x 7’ -Elevator 2 (Freight) -12’ x 7’

-Elevator 1 - 7’ x 7’ -Elevator 2 (Freight) -12’ x 7’ -Elevator 3 (Fitness Center) - 7’ x 7’

-4 Standard Accessible Parking Spaces -1 Van Accessible Parking Space PARKING / BASEMENT (-5’10”)

FITNESS CENTER / RESIDENTIAL LOBY GROUND FLOOR (+5’10”)


FITNESS CENTER / RESIDENTIAL LOBY LEVEL ACCESSIBILITY -2 Residential Accessible Entrances -1 Fitness Center Accessible Entrance -All fitness areas and privite fitness rooms are fully accessible via a 36” path or elevator FLOOR 2 - FITNESS CENTER / RESIDENTIAL LOBY (+17’6”)

ACCESSIBLE ELEVATORS

AREAS OF REFUGE

5 FT. TURNING SPACE

ESCAPE STAIRS

ACCESSIBLE UNITS

EGGRESS CORRIDOR (44” WIDTH)

FLOOR 4 - RESIDENTIAL (+40’10”)

ACCESSABILITY


PARKING / BASEMENT (-5’10”)

STRUCTURE

FLOOR 4 - RESIDENTIAL (+40’10”)


SITE CAST CONCRETE FLOORS

SITE CAST CONCRETE BEAMS

PRE-FAB STEEL STRUCTURE

STEEL COLUMNS

PILES

LOAD BEARING WALLS

PILE CAPS

SHEAR WALLS

SITECAST CONCRETE COLUMNS

DIAGONAL BRACING


INDIVIDUAL UNITS

HEAT PUMPS

MECHANICAL SERVICE ROOMS AND CHASES

AIR OUT (CEILING)

FITNESS CENTER (AIR CONDITIONED SPACE)

GEOTHERMAL WELLS (15 FT. GRID)

AIR IN (CEILING)

RESIDENTIAL LOBY (AIR CONDITIONED SPACE)

CLOSED LOOP RADIANT HEATING (FLOOR)

Geothermal Well placed beneath parking stucture supply the heat pumps.

Parking Gargae is open at ground level for natural ventilation.

Radiant Heating Tubes set in floor topping. Fed by heat pumps located in each unit. No Air Conditioning within Residential Units

BUILDING SERVICES: HVAC + PLUMBING


SUNPATH STUDY

SOLAR SHADING

CROSS VETILATION IN EACH UNIT

PASSIVE SOLAR SHADING

TERA COTTA RAIN SCREEN SOLAR SHADING

24 URBAN UNITS ONE 1/2 ACRE

RECYCLED FLYASH AGGREGATE IN SITECAST CONCRETE

1 SUBURBAN UNIT ON 1 ACRE DENSITY

SUSTAINABLILITY


TOOD JOSEPH GRACI

ARC403 SENIOR DESIGN STUDIO FALL 2009


Comprehensive Studio Portfolio