SMOKE CONTROL SYSTEM

THE FLEXIBLE SYSTEM FOR FIRE PROTECTION IN DUCTED VENTILATION SYSTEMS

SIMPLE INSTALLATION EFFORDLESS EXPANSION RELIABLE OPERATION TELEFRANG AB

www.smokecontrol.net


SMOKE CONTROL SYSTEM

EASY INSTALLATION - Single 3-core cable carries both power and network - No terminations - Open wiring topology

INTEGRATED SECURITY The system monitors and reacts to damper failure, fire alarm/BMS signal, smoke detector alarm signal and uses a “watchdog” timer for detect communication failure

FLEXIBILITY No limit to the number of dampers, the number of inputs from the fire alarm panel, BMS or duct smoke detectors, the number of fire cells / zones or the number of fire strategies.

EASY SIMPLE RELIABLE


“WITH THE USE OF A 3-CORE CABLE WE SAVE A LOT OF TIME AND CABLE AT INSTALLATION.” Daniel Johansson, Ventab, Sweden

www.smokecontrol.net


With direct connection of smoke detectors the smoke detector control unit is eliminated

SMOKE CONTROL SYSTEM

All units in the system are powered with 24VAC

CABLE AND TRANSFORMERS Simple “Rule of the thumb” creates a successful installation: - Unshielded cable 3 x 1,5 mm² - One transformer per 100m cable and or per 10 damper motors - Transformer can preferably be placed in the middle of the bus - With a communication bus over 1000m or more than 115 damper a repeater is used - A 20% over capacity on the transformer protect the motors from uneven power consumption, the damper control module itself consumes only 10-20mA GND 24VAC SIOX

24VAC

CONTROL UNIT EX2

Damper module for one damper


ST GX

SC2 & SC2 - 1

Damper module for two dampers

- Pluggable terminal blocks

- Alarm relay output

- Wiring diagram inside the lid

- Analogue input

- Inputs for damper open/closed position

- Smoke detector input

- Analogue control (0-10V) of regulating fire dampers

- Manual test button

www.smokecontrol.net


Control unit for monitoring and control of 1-400 dampers

MIDI SMOKE

Communication: Modbus TCP or Ethernet / SIOXNET

4 INPUTS Night mode Function test External fire alarm Reset of external fire alarm


4 RELAY OUTPUTS Fire Configurable control output Service alarm smoke detector Sum alarm damper / communication failure

INTEGRATION SCADA SYSTEM – ModBus TCP – SIOX NET – Digital I/O

www.smokecontrol.net


OUR CUSTOMERS DEMANS

HIGH RELIABILITY AND SAFETY

- New South Glasgow Hospital - Karolinska University Hospital - Sahlgrenska University Hospital - Ericsson (Lindholmen Science Park) - Uppsala University Hospital - Handelsbanken (Gothenburg) - Karlstads Hospital - Kristinehamn Hospital - Indian Storehouse (Stockholm) - Fysiologen - Alingsås Hospital - Läkemedelscentrum - Lidköping Hospital - Mariestad Hospital - Kärralund School - Police Head Quarters (Lund) - ..and more

OPTIONAL FUCTIONS

SOFTWARE

All damper modules are supplied with a standard PLC program for function test, smoke detector control, watchdog etc. But functions can be changed upon request. Examples of changed functions:

All software needed for commissioning and setup are available from our home page for Smoke Control System (www.smokecontrol.net). “Smoke Edit” is a software for setup of larger systems i.e. 60 fire dampers or more. Once the system has 58 dampers or fewer, setup can be carried directly using the control panel. If an alarm list is created in Excel guided by the projected documentation, it could be used for direct import to “Smoke Edit” and the system is defined. Much work in many stages saved on this manner.

- Temperature control with regulating fire damper motor. -Occupancy sensor or push button on smoke detector input. -Connection of CO2 or VOC sensor with preset level for forcing the airflow. -Lightning control via alarm relay. The above is just examples. Each different projects can conclude what functions that should be used

TELEFRANG AB

ENTROPIC LTD UNIT 3, BLOCK F, MAYNOOTH BUSINESS CAMPUS MAYNOOTH, CO. KILDARE, IRELAND

+46 31 - 40 30 60 www.entropic.ie