FEATURES 33 1.299

10 .394

• Strong against high inrush current and long life • Strong against high inrush current and long life Optical isolation: 5 ×107 operations • No chattering or bouncing and no arc generation • Both slim and flat package available • SIL (single in line) terminal layout • Zero-voltage turn-ON and Zero-current turn-OFF for eliminating surge and reducing inrush currents and EMI

25.1 .988

25 .984

33 1.299

12 .472

TYPICAL APPLICATIONS

mm inch

• Traf c signal control • Terminal equipment of data processing • Computer peripherals • NC machines • Automatic ticket punchers

TYPES 1. AQ1 Solid State Relays Zero-cross function

Load

Isolation

AC

Optically coupled isolation

Zero-cross

Optically coupled isolation

DC

2 A (Vertical) 2 A ( at)

Input voltage 3 to 28 V DC 3 to 28 V DC

5A

3 to 28 V DC

1A 2A

3 to 28 V DC 3 to 28 V DC

Type

Load current Load voltage 2 A, 75 to 250 V AC 2 A, 75 to 250 V AC 5 A, 75 to 250 V AC (3 A without heat sink) 1 A, 10 to 200 V DC 2 A, 3 to 60 V DC

Part No. AQ2A2-ZP3/28VDC AQ2A2-J-ZP3/28VDC AQ5A2-ZP3/28VDC AQ1AD2-3/28VDC AQ2AD1-3/28VDC

2. Heat sink for AQ1 solid state relay (for 5 A types): AQ-HS-5A

ORDERING INFORMATION AQ

2A

2

J

ZP

3/28 VDC

Load current

Load voltage

Shape

Type

Input voltage

1A 2A 5A

2: 75 to 250 V AC D1: 03 to 60 V DC D2: 10 to 200 V DC

Nil: Vertical type J: Flat type

Nil:DC output ZP: AC output (Zero-cross)

3/28 V DC: 3 to 28 V DC

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.


AQ1 SPECIFICATIONS Rating (at 20°C 68°F, Ripple factor: less than 1%) 1. AC output type Zero-cross 2A Input voltage Input side

Load side

Remarks

5A 3 to 28 V DC Approx. 1.6 k Ω (3 to 28 V DC) 0.8 V

Input impedance Drop-out voltage, min. Max. load current Load voltage

2A

Non-repetitive surge current

80 A

5 A*

at ambient temperature 40°C 104°F

75 to 250 V AC

See “REFERENCE DATA 2-(1), (2)” In one cycle at 60 Hz at 200 V AC 60 Hz at Max. carrying current

100 A

Max. “OFF-state” leakage current Max. “ON-state” voltage drop Min. load current

5 mA 1.6 V 50 mA

*5 A with heat sink 3 A without heat sink see “REFERENCE DATA 1-(2)”

2. DC output type 1 A type Input side

Load side

Input voltage Input impedance Drop-out voltage, min. Max. load current Load voltage Non-repetitive surge current Max. “OFF-state” leakage current Max. “ON-state” voltage drop Min. load current

2 A type

Remarks

3 to 28 V DC Approx. 1.6 k Ω 0.8 V 1A 10 to 200 V DC

2A 3 to 60 V DC

at ambient temperature 40°C 104°F

1.6 V

at 200 V AC 60 Hz at Max. carrying current

5 A (1 s) 1 mA 2.3 V 5 mA

Characteristics (at 20°C 68°F, Ripple factor: less than 1%) AC output Zero-cross Operate time, Max. Release time, Max. Insulation resistance, Min. Breakdown voltage Vibration resistance

Shock resistance

5A (1/2 cycle of voltage sine wave) + 1 ms (1/2 cycle of voltage sine wave) + 1 ms 100 M Ω for input, output and case 3,000 Vrms between 3,000 Vrms between input and output input and output 1,500 Vrms among input, output and case

DC output

Remarks

2A

0.5 ms 2 ms 100 M Ω for input, output at 500 V DC 3,000 Vrms between input-output

Destructive

117.6 m/s2 {12G}, 10 to 55 Hz at double amplitude of 2 mm

Functional

117.6 m/s2 {12G}, 10 to 55 Hz at double amplitude of 2 mm

Destructive

Min. 980 m/s2 {100 G}

Min. 980 m/s2 {100 G}

Functional

Min. 980 m/s2 {100 G}

Min. 980 m/s2 {100 G}

Ambient temperature Storage temperature Operational method

–30°C to +80°C –22°F to +176°F –30°C to +100°C –22°F to +212°F Zero-cross (Turn-ON and Turn-OFF)

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

1 hour for X, Y, Z axis 10 minutes for X, Y, Z axis 5 times each for X, Y, Z axis 4 times each for X, Y, Z axis


AQ1 mm inch

DIMENSIONS AC output, 2A type (vertical)

Mounting hole location (Copper-side view)

33 1.299

25 INPUT .984 +3 4 – 1 .039

LOAD 1

1

2

6 .236

2 2.54 × 3 .100 × 3

7.62 12.7 5.08 .300 .500 .200 25.4 1.000 C2

25.4 1.000

4

2.54 × 5 .100 × 5

0.8 .031 5.7 .224

4-1.2DIA. 4-.047DIA.

2.54 × 2 .100 × 2

Schematic SSR

5.0 .197

10 .394

4-0.8DIA. 4-.031DIA.

Copper foil 3

LOAD 1 2

INPUT 3 4

+ – Load Input Load power source power source

General tolerance: ±0.5 ±.020

Tolerance: ±0.1 ±.004

AC output, 2A type (Flat)

Mounting hole location (Copper-side view)

33 1.299 6 .236

4-0.8DIA. 4-.031DIA.

1 .039

0.8 .031

3+

6.55 .258

10.16 .400

12.7 .500 4 1

2

INPUT

10.16 .400

2

3

7.82 .308

25.4 1.000

4-1.2DIA. 4-.047DIA.

25.4 1.000

Copper foil

11 .433

LOAD

4–

12.7 25 .500 .984

Schematic

1

Input power source + –

Load power source

Load

General tolerance: ±0.5 ±.020 2

3

SSR LOAD

INPUT

1

4

Tolerance: ±0.1 ±.004

AC output, 5A type

Mounting hole location (Copper-side view) 54 2.126 41 1.614 33 1.299 25 .984

LOAD

1 2

1

0.8 .031

Copper foil

4 .157

2

3

2.54 × 3 .100 × 3

2.54 × 5 .100 × 5

INPUT

4 9.1 .358

2.54 × 2 .100 × 2

+ 34 – 1 .039

15 min. .591

4-1.2DIA. 4-.047DIA.

25.4 1.000

7.62 .300 12.7 5.08 7.62 .500 .200 .300

0.6 .024

2 .079 6.9 .272 12 max. .472

20 .787

2-3.5DIA.* 2-.138DIA.

20 .787

* There 2 holes are not necessary when not using heat sink (AQ-HS-5A)

Schematic

C2 SSR 2 2 .079 8.89 10.16 .079 .350 .400

General tolerance: ±0.5 ±.020

LOAD 1 2

INPUT 3 4

+ – Load Input Load power source power source

Tolerance: ±0.1 ±.004 All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.


AQ1 Heat sink (for AC output, 5A type) AQ-HS-5A

mm inch

58±2 2.283±.079

2-M3 Screw

13.8 .543 27±2 1.063±.079 5.2 .205

47.6 1.874 40 1.575

2.5 .098

9 .354

30±2 1.181±.079 2-M3 Screw depth: min. 10mm 8 8 8 8 8 8 8 .315.315.315.315.315.315.315

Knurl surface

When using heat sink, please refer to “Thermal Design (Page 25)”

General tolerance: ±0.5 ±.020

DC output, 1A, 2A types

Mounting hole location (Copper-side view) 33 1.299

25 .984 +3 4 – 1 .039

LOAD 1

1

INPUT

2

6 .236

2.54 × 3 .100 × 3

7.62 12.7 5.08 .300 .500 .200 25.4 1.000 C2

Copper foil 3

2.54 × 5 .100 × 5

4

4-1.2DIA. 4-.047DIA.

2.54 × 2 .100 × 2

Schematic

0.8 .031 5.7 .224

SSR

5.0 .197

10 .394

4-0.8DIA. 4-.031DIA.

25.4 1.000

2

LOAD 1 2

INPUT 3 4

+ – + – Load Input Load power source power source

General tolerance: ±0.5 ±.020

Tolerance: ±0.1 ±.004

REFERENCE DATA 1. Load current vs. ambient temperature (1) AC output zero-cross type (2 A type)

(2) AC output zero-cross type (5 A type)

2.5 (e) 5 Load current, A

Load current, A

2.0 1.5 1.0

(d)

3 2

0.5 0 –30

4

1 0

20 40 60 80 Ambient temperature, °C

0 –30

0

d. External heat sink is not used. e. In the case of mounting on heat sink (AQHS-5A) or 66 × 66 × 2.0 thick aluminum plate. The AQ-HS-5A heat sink is mounted on the printed circuit board. The load current is improved compared with the unmounted condition as indicated in the diagram above. When the 5 A type heat sink (AQ-HS-5A) or a heat sink is not use, in order to provide good cooling conditions, the back surface plate should be exposed.

20 40 60 80 Ambient temperature, °C

Allowable ambient temperature: –30°C to +80°C –22°F to +176°F

2.5

Load current, A

2.0

(a)

1.5 (b) 1.0 0.5 0 –30

0

a. DC type (2 A type) Allowable temperature range: –30°C to +80°C –22°F to +176°F b. DC type (1 A type) Allowable temperature range: –30°C to +80°C –22°F to +176°F

2. Non-repetitive surge current vs. carrying time (1) AC output zero-crossing type (2 A type) Non-repetitive surge current, A

(3) DC type (1 A, 2 A type)

100

50

10 50 No. of cycles at 60 Hz

20 40 60 80 Ambient temperature, °C

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

100


Non-repetitive surge current, A

AQ1

NOTE

All Rights Reserved Š COPYRIGHT Matsushita Electric Works, Ltd.

Panasonic AQ1 Relays  

Panasonic AQ1 Relays

Advertisement