Cushion Lock Circuit

.94

5.25

S V1

YCGG L*N ** CBG* LAN

V2

SARASOTA, FL. USA

CBG*

CBG* T

1.84

C1

C2

0 5.00

0

5.00

Cushion lock circuits control the starting, running and stopping of reciprocating or rotary reversing circuits. The standard manifold assembly above includes two CBG*-L*N counterbalance cartridge valves, two CXGDXAN checks, two CXHA-XAN checks, and a CSAD-XXN shuttle, which provides a signal to release a spring-applied mechanical brake. Hydraulic fluid is not returned through the directional control valve. A tank port offers a connection to cool or filter the return oil. This assembly is available in various configurations and sizes, with various connection options. The assembly provides:     

Deceleration control Load locking Overrunning load control Thermal relief protection Protection from intensification

Assemblies are available with Series 1 through Series 4 cartridge valves, with flow capacities from 60 L/min. to 480 L/min. Click here for additional information.