Renice Solid State Drive Testing Method

High Low Temperature Test includes temperature cycles and temperature shocks. Note: "due to a large amount of frost becoming condensation during the transition from low temperature to high temperature, droplets will cause the short-circuit directly to the chip pins that burned out the SSD, so, the tested SSD must be reinforced and waterproofed." Here is the picture of frosted testing board at -40 °C

Temperature Test Cycles Temperature cycle: set the temperature at -50 ° C and keep for 4 hours, next raise to + 90 ° C and keep for 4 hours, and then decrease to -50 ° C for N cycles sequentially. Industrial temperature standard is -40 to 85. As for the temperature difference at the high-low temperature chamber, our internal test advise to use the standard temperature ± 5 ° C for testing to ensure the same testing results at end-user. Test Process: 1. Decrease the temperature to -50°C at power off and keep for 4 hours. Please don't operate the low temperature test when power is on. It is very important that Chip itself will generate + 20 ° C, so, it easily to pass the low temperature test when power is on. We must freeze completely the disk and then boot to test others 2. Power on and test the read/write performances whether normal compare with standard temperature. 3. Burning Test: to see any errors occurs 4. Power Cycle Test 5. Raise the temperature to +90°C and keep for 4 hours. The test is different with low temperature that keeping the internal temperature of the chip at the high temperature in the process of raise and follow the 2、3、4 steps after 4 hours.


6. High and low temperature test repeat 10 times. If any error occurs in the process of test, the test failed.

Temperature Shock Test Temperature shock: the rapid transition from low to high temperature in a few minutes (or defined the time), as well as fast transitions from high to low temperatures. The general setting is from low temperature, the transition time from -50 ° C to +90 ° C lower than 3 mins, or start the same test from high to low temp(-50 ° C to +90 ° C). You can run the burning test to compare the data whether any errors in the process of rapid transition of temperature. The detail testing standard refer to : GB/T 2423.34,IEC 60068-2-38,GJB150.5

Renice Solid State Drive Testing Method  

High Low Temperature Test includes temperature cycles and temperature shocks. Renice Solid State Drive Testing Method will help you how to...

Renice Solid State Drive Testing Method  

High Low Temperature Test includes temperature cycles and temperature shocks. Renice Solid State Drive Testing Method will help you how to...

Advertisement