Telephone Interface / Alarm Dialler Gx-TEL The G1-TEL / G2-TEL / G7-TEL multipurpose interface card builds a bridge between Intercom networks and telephone networks or pagers. Every interface card may be configured for one of three possible modes: Telephone mode: The Intercom stations can call any desired telephone number. Conversely, the Intercom stations can also be called from any telephone. In addition all Intercom functions can be activated via the DTMF keypad of the remote telephone, e.g. All Calls, Group Calls, Door Calls with after-dialling for door opening, etc.

quences. The called telephone receives a voice message identifying the calling station by means of integrated, userprogrammable speech storage (up to 100 different messages). The telephone can talk to the caller and, if necessary, activate remote access functions, e.g. open a door. Pager mode: To call pagers made by different manufacturers from any Intercom station. The telephone interface is connected to the telephone interface of the pager system. The output protocol (order of the digits) can be adapted to suit the different paging systems.

Auto dialler mode (alarm dialler): Calls and Call Requests from the Intercom central initiate predefined dialling se1.

G7-TEL Telephone interface for connection of the Intercom Server GE 700 to an analogue PABX subscriber, to a standard telephone line or to a pager system.

2.

GEA TEL Installation board for G7-TEL to be mounted on the GE 700.

3.

G1-TEL, G2-TEL Telephone interface for connection of the Intercom Servers GE 100 or GE 200 to an analogue PABX subscriber, to a standard telephone line or to a pager system. Type G1-TEL for GE 100, type G2-TEL for GE 200.

Commend, Inc. · 63 Ramapo Valley Road, Suite 201 · Mahwah, New Jersey 07430 · Tel. (201) 529-2425 · Fax (201) 529-0008 · office@commendusa.com · www.commendusa.com Datasheet Version 2.1/1207 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice.

www.commend.com

P1|4


DATASHEET

Gx-TEL

Technical Data – Benefits TECHNICAL DATA

BENEFITS

Operating temperature range:

0°C to +50°C (32° F to 122° F)

Storage temperature range:

–30°C to +60°C (–22° F to 140° F)

Relative humidity: Plug:

20% to 80%

G1-TEL, G2-TEL: 40-way socket G7-TEL: 96-way pc board connector according DIN 41612 telephone connection: RJ 11

Power supply:

from central

Emergency power consumption:

0.1 Ah/h

Measurements: G1-TEL, G2-TEL: 60 x 160 mm (2.36 x 6.30 in), G7-TEL: 100 x 167 mm (3.94 x 6.58 inch) Weight including package:

G1-TEL, G2-TEL: 344 g (0.76 lbs) G7-TEL: 395 g (0.87 lbs)

Dialling method:

DTMF

• Integrates auto dialler, telephone interface and pager interface • Connection to a trunk line or to an analogue PABX extension port. • Speech storage for generating of messages from WAV files as information for the calling Intercom station and for the remote telephone (max. 100 messages, 800 seconds in total) • Predefined numbers (for paging and for auto dialler mode), predefined dialling sequences (e.g. for day/night operation) • Dial up connections between Intercom stations and telephone sets • Simplex control • Operation of Intercom features (e. g. after dialling for door opening) via DTMF phones (DECT phones, GSMs, etc.) • Approved for all countries within the EU

Speech storage capacity: 100 messages, 800 seconds in total Hardware specifications:

according to CTR 21 and EG 201121

SYSTEM REQUIREMENTS GE 100: • Software from Pro 04.7D onwards, for programming the corresponding configuration tool (minimum TE 700 version 4.7D) is required. • It is not possible to use a G7-TEL in an interface housing GEI 100 (has worked until Pro 04.7D) .

EXTENT OF SUPPLY G1-TEL, G2-TEL: 1 telephone interface card including: • Connection cable 3 m (9.8 ft)

GE 200:

• Telephone adapter

• Software from Pro 04.7D onwards, for programming the corresponding configuration tool (minimum TE 700 version 4.7D) is required.

• CD “Software and Manuals“

• A link card G2-GEK2-3 is required in each housing containing a G2-TEL card and in each housing containing 4-wire subscriber cards.

G7-TEL:

• If necessary, a G7-TEL can be used in an interface housing GEI 200, but then only one G2-TEL may be used in the GE 200/GEZ 200. Software from Pro 04.5 onwards is required for G7-TEL.

• Short reference

1 telephone interface card including: • Installation board GEA TEL • Connection cable 3 m (9.8 ft) • Telephone adapter • CD “Software and Manuals“ • Short reference

GE 700: • Software from Pro 04.5 onwards, G7-GEV with software from V1.5 onwards. • A link card G7-GEK3-4 (with software from V2.0 onwards) is required in each housing containing a G7-TEL card and in each housing containing 4-wire subscriber cards

Commend, Inc. · 63 Ramapo Valley Road, Suite 201 · Mahwah, New Jersey 07430 · Tel. (201) 529-2425 · Fax (201) 529-0008 · office@commendusa.com · www.commendusa.com Datasheet Version 2.1/1207 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice.

www.commend.com

P2|4


DATASHEET

Gx-TEL

Functions BASIC FUNCTIONS

AUTO DIALLER MODE

The analogue Telephone Interface can be used for any one of the following functions:

• The Auto Dialler Mode is used for transfer of Intercom calls and input messages (central control calls) to predefined telephone numbers.

1.

Auto Dialler Mode

2.

PABX Mode (Telephone mode)

3.

Pager Mode

• It is also possible to dial from any telephone into the Intercom Server.

GE 100 GE 200 GE 700

G-TEL

Auto dialler public telemode phone net

• Intercom functions can be carried out with the DTMF keyboard of the telephone. Telephone numbers / Dialling sequences • The telephone numbers and the order, in which the telephone numbers shall be dialled, can be programmed (8 telephone numbers, 8 dialling sequences with 15 entries each). The dialling sequences are selected via inputs.

PABX mode

public telephone net

Operation at the telephone • The call is accepted by entering a 1- to 4-digit code (standard #). A call request has to be accepted with # a second time. • Speech messages can be interrupted with * (loudspeaking call) or # (call request), but each message has to be listened to at least once.

SOS

Pager mode

Pager central

• With software until Pro 04.6 * had to be pre-dialled for after dialling functions during a conversation (e.g. *1 for door opening, *7 for microphone mute). With software from Pro 04.7 onwards no pre-dialling is necessary. • A conversation is cancelled with #. • Simplex operation: pressing the * button toggles talk/listen modes.

TELEPHONE MODE • An authorised Intercom station calls the telephone interface (with the calling number of the interface or with a 1- to 4-digit code). Afterwards any telephone number can be dialled. • By calling the telephone number of the interface, any telephone can call into the Intercom Server. • An optional 1- to 4-digit password can be defined for the telephone (standard #). • With the DTMF keyboard of the telephone Intercom functions can be carried out.

PAGER MODE • Radio pagers can be called from any authorised Intercom station. • 2-, 3- or 4-digit dialling to the pagers. • Simple connection to the telephone interface of the pager system (2 wires). • The output protocol (order of the digits) can be adapted to the different paging systems (also ESPA protocol). • Transfer of call requests from an SA 101 central control desk to pager.

Speech storage • As information for the calling Intercom station and for the telephone different speech messages are available. • The calling Intercom station receives a “Calm down message“ (e.g. “Your call has been acknowledged and will be answered shortly“). • The telephone receives a “Location message“ after lifting the receiver as information where the call comes from. This message should be individually recorded (e.g.: “Parking North“). • If the initiated calls are call requests, the telephone receives a “Call request message“ (e.g. “Calls: two, emergency calls: three“). • For each call mode (conversation, call or emergency call) and for each Intercom station additional “Individual messages“ can be defined (e.g.: “Call from station one-zero-five“). • The telephone interface is delivered with standard audio files for all call types, but it is also possible to record your own messages. With software from Pro 04.7D onwards it is possible to record messages at an Intercom station. WAV-files recorded at a PC can be loaded with a software package available at your dealer. • Speech storage capacity: 100 messages, total of 800 seconds.

Commend, Inc. · 63 Ramapo Valley Road, Suite 201 · Mahwah, New Jersey 07430 · Tel. (201) 529-2425 · Fax (201) 529-0008 · office@commendusa.com · www.commendusa.com Datasheet Version 2.1/1207 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice.

www.commend.com

P3|4


DATASHEET

Gx-TEL

Installation PRECAUTIONS

CONNECTION G1-TEL, G2-TEL

• ESD precautions must be observed.

Telephone line: a b

• Cards may be inserted or removed only with voltage switched off.

NC NC

NC NC

• Mounting and installation of the centrals and of the equipment may be carried out by authorised service personnel only. Status-LEDs: Run Line

• The equipment has been approved to european law 98/482/EC for pan-European single terminal connection to the Public Switch Telephone Network (PSTN). However, due to differences between the induividual PSTNs provided in different countries, the approval does not, of itself, give unconditional assurance of successful operation on every PSTN network termination point. In the event of problems, you should contact your equipment supplier in the first instance. • Installation Reference for Germany: The interface G1-TEL / G2-TEL / G7-TEL may be connected to an analogue telephone connection only as single dialling equipment. Use the F-coded TAE-plug.

CONNECTION G7-TEL In a Intercom server GE 700 the G7-TEL card can be installed in the slots 1 to 12 or A of the central (a maximum of 8 cards per housing).

GE 100 • The plug-in card G1-TEL can be inserted in any slot of the basic central GE 100 or of the expansion central GEZ 100 and works only with central software from Pro 04.7D onwards and with the corresponding configuration tool (minimum TE 700 version 4.7D). • In GE 100 and GEZ 100 together one G1-TEL may be inserted (together one). GE 200

Installation board GEA TEL For connection the installation board GEA TEL, which is included in the extent of supply, has to be used. Plug connection Telephone line a b NC NC

GEATEL

NC NC

• The plug-in card G2-TEL can be inserted in any slot of the basic central GE 200 or of the expansion central GEZ 200 and works only with central software from Pro 04.7D onwards and with the corresponding configuration tool (minimum TE 700 version 4.7D). • Per GE 200 and GEZ 200 one G2-TEL may be inserted (together two). G7-TEL in a GEI 200 • If necessary, a G7-TEL can be used in an interface housing GEI 200, but then only one G2-TEL may be used in the GE 200/GEZ 200. Software from Pro 04.5 onwards is required for G7-TEL. • The interface housing GEI 200 is connected to the expansion plug of the GE 200, or, if an expansion housing GEZ 200 is connected there, to the expansion plug of the GEZ 200.

N.C.

Slot 10 (“Slot n+1“) GEATEL Slot 9 (“Slot n“)

G7-TEL GEI 200

GEZ 200

GE 200

Commend, Inc. · 63 Ramapo Valley Road, Suite 201 · Mahwah, New Jersey 07430 · Tel. (201) 529-2425 · Fax (201) 529-0008 · office@commendusa.com · www.commendusa.com Datasheet Version 2.1/1207 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice.

www.commend.com

P4|4

http://www.sourceav.com/Files/Commend/Data_Sheets_Telephone_Interface/DS-Gx-TEL-CU-EN-V21-1207  

http://www.sourceav.com/Files/Commend/Data_Sheets_Telephone_Interface/DS-Gx-TEL-CU-EN-V21-1207.pdf

Advertisement