Page 1


600

300

16

760

632

Zip G4 Command Centre

585

ZP01

TA01

LINE OF OVERHEAD CUPBOARDS

7

CD5001

SI01 DW01

1

01

525

25

01

FL02

4

500

6

CD5001

01

LINE OF OVERHEAD CUPBOARDS

J01 KITCHETTE

3

FR01

825

412

2.850 CL

400 10

3 CD5002

LM02

LM02 ADJ.

LM02

ADJ.

ADJ.

ADJ.

ADJ.

ADJ.

720

ADJ.

LM02

LM02

LM02

4

AB DGPO

PROVISION FOR MICROWAVE

LM02 778

LM02

PROVISION FOR MICROWAVE

LM03

LM03

SHADDOW GAP

TA01

ZP01 35

SI01

TA01 30

ZP01

CL

280

LM01 FIXED PANEL

SINGLE GPO LM02 FR01

LM02 900

BT01

LM02 UNDER SINK CLEARANCE SHOWN DASHED TO COMPLY WITH AS 1428.2-1992

LM02 385

550

10AMP POWER SUPPLY FOR ZIP G4 ZIP G4 UNDER SINK COMMAND CENTRE

J01 ELEVATION SOUTH WALL

REMOVABLE ACCESS PANEL FOR ACCESSIBILITY TO PLUMBING BEYOND

J01 ELEVATION WEST WALL

FFL 0.150

257

710

LM02

DW01

FR01

45

SINGLE GPO

BT01

797

797

LM02

SI01

797

AB DGPO

1500

CD5002

200

J01 SECTION 1

KITCHENETTE JOINERY DETAILS 0

1

scale

1 : 100

2

3

4

@ A3

5m

HERITAGE BUILDING REFURBISHMENT AND FITOUT

DATE

PROJECT NUMBER

DRAWING NUMBER

09/05/14

13036

01

REV -


660

950

180 242 STAFF LOCKERS (2 DOOR INTERLOCKING x 4) WITH BENCH SEAT

1230

MIN. CIRCULATION SPACE; LATCH-SIDE APPROACH IN ACCORDANCE WITH AS 1428.1 D.02

950

560

MIN. CIRCULATION SPACE; EITHER SIDE APPROACH IN ACCORDANCE WITH AS 1428.1

990

660

CHANGE DOOR TO INTERNAL POCKET SLIDER TO MAXIMISE INTERNAL AND EXTERNAL DOOR CIRCULATION

1280

W06

1212

1212

04

4 (1800MM x 750MM)

8015

2 (1800MM x 750MM)

1

6 (1500MM x 750MM)

1 (1500MM x 750MM)

7 (1800MM x 750MM) POSITION OF WALL MOUNTED LCD SCREENSTO BE SUPPLIED BY CLIENT

5 (1800MM x 750MM)

POSITION OF WALL MOUNTED LCD SCREENSTO BE SUPPLIED BY CLIENT

3 (1800MM x 750MM)

1

8 (1800MM x 750MM)

100

07

395

100

1280

1380

1200

W07

MIN. CIRCULATION: SIDE-SIDE APPROACH IN ACCORDANCE WITH AS 1428.1 W07

100

D.01

GLAZED SIDE PANEL

100 1200

254

SHIFT POSITION AND ORIENTATION OF GLAZED SLIDER TO ALLOW DIRECT PASSAGE THROUGH CONTROL ROOM INTO MEETING ROOM/KITCHENETTE

LOTUS ACOUSTIC GLAZED SINGLE SLIDER, FACE FIXED

100

1280

FROSTED GLAZED SIDE PANEL

395

100

MIN. CIRCULATION: SIDE-SIDE APPROACH IN ACCORDANCE WITH AS 1428.1 ALLOWANCE FOR WALL THICKNESS FOR SURFACE-MOUNTED DOOR

5845

CONTROL ROOM WORKSTATION LAYOUT 0

scale

500

1 : 50

1000

1500

2000

@ A3

2500 mm

HERITAGE BUILDING REFURBISHMENT AND FITOUT

DATE

PROJECT NUMBER

DRAWING NUMBER

25/08/14

13036

02

REV B


EXISTING GLAZED WINDOW

EXISTING SPLITFACE BLOCK

EXISTING SECURITY CAMERA

TITLE BOUNDARY

EXISTING STRING-COURSE BRICKWORK

WL02

1000

WL03

W01

EXISTING FIRE ALARM EXISTING FILIGREE BLOCKS

EXISTING ELECTRICAL PANEL

1390

WL04

3100 EXISTING DOOR

NEW TIMBER WINDOWS WITH DOUBLE GLAZING, TO MATCH EXISTING GLAZED WINDOW

592

NEW CEMENT RENDER OVER BLOCK TO MATCH COLOUR OF EXISTING STRING-COURSE BRICKWORK ABOVE; BLOCKWORK INFILL WALL RECESSED 60mm BEHIND ALIGNMENT OF FACADE

EXISTING POLISHED PRE-CAST CONCRETE

EAST ELEVATION 0

1

scale

1 : 100

2

3

4

@ A3

5m

HERITAGE BUILDING REFURBISHMENT AND FITOUT

DATE

PROJECT NUMBER

DRAWING NUMBER

09/03/14

13036

03

REV -


TITLE BOUNDARY

EXISTING BRICK WALL

EXISTING PARAPET CAPPING ON EAST ELEVATION

WL01

NEW 150MM OGEE GUTTERING NEW CEMENT RENDER OVER LIGHTWEIGHT STRUCTURE; FINISH TO MATCH COLOUR OF EXISTING STRING-COURSE BRICKWORK R01 W05

ROOF CANOPY; LYSAGHT INTEGRITY 820 OVER ACCESSIBLE RAMP

NEW 150MM OGEE GUTTERING COLUMNS SUPPORTING EXTERNAL ROOF / RAMP COVER; REFER TO STRUCTURAL DRAWINGS

R01

RG01

RG01 DP01 WL04

3400

WL04

W04 C1

D.05 D.04

C1

CR

DP01

900

HR01 300 PLANT ROOM SLIDING DOOR DOOR; SCREEN TO WITH ALUMINIUM BE PROVIDED FRAME WITH 60% FREE AREA BY BUILDER

1:14 GALVANISED STEEL ACCESSIBLE HAND RAILING, CONCRETE 300MM EXTENSION, RAMP END TURNED THROUGH 180 DEG

WINDOW WITH EXISTING FIXED PANEL (RELOCATED) GLAZING TO CONDENSER UNIT MATCH EXISTING WEST WINDOW

EXISTING DOOR

EXISTING WINDOW

EXISTING AIR CONDITIONING WALL MOUNTED UNIT

BICYCLE RACKS (x5)

WEST ELEVATION 0

1

scale

1 : 100

2

3

4

@ A3

5m

HERITAGE BUILDING REFURBISHMENT AND FITOUT

DATE

PROJECT NUMBER

DRAWING NUMBER

02/09/14

13036

05

REV -


TITLE BOUNDARY

EXISTING PARAPET CAPPING

EXISTING SECURITY CAMERA

LINE OF EXISTING BUILDING BEYOND WL03

EXISTING SPLITFACE BLOCK

ROOF CANOPY; LYSAGHT INTEGRITY 820 OVER UNISEX ACCESSIBLE W/C AND SHOWER

NEW 150MM OG GUTTER AND DOWNPIPE

R01 W05

EXISTING STRING-COURSE BRICKWORK

W05

LINE OF EXISTING FENCE TO THE NORTH BOUNDARY (TO REMAIN)

3550

WL04

RG01

EXISTING CAR PARK DP01

WL02

EXISTING STRING-COURSE BRICKWORK

PROPOSED STRUCTURE TO BE MECHANICALLY TIED BACK TO THE EXISTING BUILDING; CONTROL JOINT TO BE FILLED WITH BRICK AND CONCRETE SILICONE SEALANT

6365

150

EXISTING POLISHED PRE-CAST CONCRETE

5600

NEW CEMENT RENDER OVER STRUCTURE; FINISH TO MATCH COLOUR OF EXISTING STRING-COURSE BRICKWORK

NORTH ELEVATION 0

1

scale

1 : 100

2

3

4

@ A3

5m

HERITAGE BUILDING REFURBISHMENT AND FITOUT

DATE

PROJECT NUMBER

DRAWING NUMBER

09/03/14

13036

04

REV -

Folio 2013  
Read more
Read more
Similar to
Popular now
Just for you