Issuu on Google+

Eland Cables’ Datasheet Rail Cable | Product Group Telecom

Copper Trackside Cable

www.eland.co.uk

Eland Product Group A8T Application Suitable for installation in trackside concrete cable troughing, buried duct route or for direct burial installations. Standards NR/PS/TEL/00015 (formerly RT/E/ PS/00015) Conductor Class 1 solid conductor to BS6360 Insulation PVC (Polyethylene) Type 03 to BS6234 Moisture Protection Petroleum Jelly filled Tape Impregnated Paper and/or Non Hygroscopic Tape Moisture Barrier Aluminium/Polymer Laminate Tape Sheath PVC (Polyethylene) Type 03C to BS6234 or LSZH (Low Smoke Zero Halogen) Sheath Colour Black Temperature Rating -25 to +85°C Minimum Bending Radius 10 x overall diameter

Dimensions PE Armoured 0.63mm² Number of Pairs

Eland Part Number

Rail Catalogue Number

Nominal Inner Thickness of Sheath Min. mm

Nominal Outer Thicknes of Sheath Min. mm

Ratio Min.:Max.

Nominal Overall Diameter mm

Nominal Weight kg/Km

2

A8T0263S

-

1.6

1.6

0.75

18.0

5

A8T0563S

-

1.6

1.6

0.75

19.5

285

10

A8T1063S

-

1.6

1.6

0.75

21.3

380

205

20

A8T2063S

-

1.6

1.6

0.75

23.8

550

30

A8T3063S

-

1.6

1.6

0.75

26.1

690

50

A8T5063S

-

1.6

1.6

0.75

29.9

960

75

A8T7563S

-

1.6

1.6

0.75 w

33.9

1260

100

A8T10063S

-

1.6

1.6

0.75

36.7

1610

Eland Part Number

Rail Catalogue Number

Nominal Inner Thickness of Sheath Min. mm

Nominal Outer Thicknes of Sheath Min. mm

Ratio Min.:Max.

Nominal Overall Diameter mm

Nominal Weight kg/Km

PE Armoured 0.9mm² Number of Pairs

2

A8T0209S

-

1.6

1.6

0.75

19.0

250

5

A8T0509S

-

1.6

1.6

0.75

21.3

365

10

A8T1009S

-

1.6

1.6

0.75

23.8

520

20

A8T2009S

-

1.6

1.6

0.75

27.6

820

30

A8T3009S

-

1.6

1.6

0.75

30.9

1060

50

A8T5009S

-

1.6

1.6

0.75

35.7

1550

75

A8T7509S

-

1.6

1.6

0.75

41.5

2100

100

A8T10009S

-

1.6

1.6

0.75

36.7

1610

-

1.6

1.6

0.75

44.8

2715

Eland Part Number

Rail Catalogue Number

Nominal Inner Thickness of Sheath Min. mm

Nominal Outer Thicknes of Sheath Min. mm

Ratio Min.:Max.

Nominal Overall Diameter mm

PE Duct 0.63mm² Number of Pairs

Nominal Weight kg/Km

2

A8T0263

-

1.6

1.6

0.75

10.5

71

5

A8T0563

-

1.6

1.6

0.75

12.0

120

10

A8T1063

6/168013

1.6

1.6

0.75

13.8

190

20

A8T2063

6/168014

1.6

1.6

0.75

16.3

325

30

A8T3063

6/168015

1.6

1.6

0.75

18.6

435

50

A8T5063

6/168016

1.6

1.6

0.75

22.4

660

75

A8T7563

-

1.6

1.6

0.75

26.4

930

100

A8T10063

-

1.6

1.6

0.75

29.2

1230

-

1.6

1.6

0.75

44.8

2715

Eland Part Number

Rail Catalogue Number

Nominal Inner Thickness of Sheath Min. mm

Nominal Outer Thicknes of Sheath Min. mm

Ratio Min.:Max.

Nominal Overall Diameter mm

PE Duct 0.9mm² Number of Pairs

Nominal Weight kg/Km

2

A8T0209

6/168061

1.6

1.6

0.75

11.5

95

5

A8T0509

-

1.6

1.6

0.75

13.8

180

10

A8T1009

6/168063

1.6

1.6

0.75

16.3

300

20

A8T2009

6/168064

1.6

1.6

0.75

20.1

545

30

A8T3009

6/168065

1.6

1.6

0.75

23.4

750

50

A8T5009

6/168066

1.6

1.6

0.75

28.2

1175

75

A8T7509

-

1.6

1.6

0.75

34.0

1690

100

A8T10009

-

1.6

1.6

0.75

37.3

2250

-

1.6

1.6

0.75

44.8

2715

Datasheet Continues »

Issue_01_0508


Eland Cables’ Datasheet

Copper Trackside Cable [Continued] LSZH Armoured 0.63mm² Number of Pairs

Eland Part Number

Rail Catalogue Number

Nominal Inner Thickness of Sheath Min. mm

Nominal Outer Thicknes of Sheath Min. mm

Ratio Min.:Max.

Nominal Overall Diameter mm

Nominal Weight kg/Km

2

A8T0263S-ZH

-

1.6

1.6

0.75

19.8

330

5

A8T0563S-ZH

-

1.6

1.6

0.75

21.3

425

10

A8T1063S-ZH

6/168033

1.6

1.6

0.75

21.8

550

20

A8T2063S-ZH

6/168034

1.6

1.6

0.75

26.1

740

30

A8T3063S-ZH

6/168035

1.6

1.6

0.75

28.4

880

50

A8T5063S-ZH

6/168036

1.6

1.6

0.75

32.2

1150

75

A8T7563S-ZH

-

1.6

1.6

0.75

35.7

1450

100

A8T10063S-ZH

-

1.6

1.6

0.75

38.5

1760

-

1.6

1.6

0.75

44.8

2715

Rail Catalogue Number

Nominal Inner Thickness of Sheath Min. mm

Nominal Outer Thicknes of Sheath Min. mm

Ratio Min.:Max.

Nominal Overall Diameter mm

1.6

1.6

0.75

21.3

380

1.6

1.6

0.75

23.1

520

LSZH Armoured 0.9mm² Number of Pairs

Eland Part Number

2

A8T2009S-ZH

5

A8T0509S-ZH

10

A8T1009S-ZH

6/168083

1.6

1.6

0.75

26.1

700

20

A8T2009S-ZH

6/168084

1.6

1.6

0.75

29.9

1000

30

A8T3009S-ZH

6/168085

1.6

1.6

0.75

33.2

1240

50

A8T5009S-ZH

6/168086

1.6

1.6

0.75

38.0

1720

75

A8T7509S-ZH

-

1.6

1.6

0.75

43.3

2235

100

A8T10009S-ZH

-

1.6

1.6

0.75

46.6

2780

1.6

1.6

0.75

44.8

2715

-

-

6/168081

Nominal Weight kg/Km

-

-

Electrical Characteristics 2Pr

5Pr

10Pr

20Pr

30Pr

50Pr

75Pr

100Pr

Max. Average at 20°C

58.0

58.0

58.0

58.0

58.0

58.0

58.0

58.0

Max. at 20°C

60.0

60.0

60.0

60.0

60.0

60.0

60.0

60.0

Conductor Resistance 0.63mm² (ohms/Km)

Conductor Resistance 0.90mm² (ohms/Km) Max. Average at 20°C

28.0

28.0

28.0

28.0

28.0

28.0

28.0

28.0

Max. at 20°C

30.0

30.0

30.0

30.0

30.0

30.0

30.0

30.0

Insulation Resistance Min. (Mohms/Km)

1500.0

1500.0

1500.0

1500.0

1500.0

1500.0

1500.0

1500.0

-

-

-

-

-

-

-

Mutal Capacitance (nF/Km) Max. Average

70.0

70.0

70.0

70.0

67.0

67.0

67.0

67.0

Max. for 99% pairs

79.0

79.0

79.0

79.0

75.0

75.0

75.0

75.0

Capacitance Unbalance (Max. pF/500m)

800.0

275.0

275.0

275.0

275.0

275.0

275.0

275.0

1.40

Attenuation dB/Km Max. Average 0.63mm² 1.0KHz

-

-

-

1.40

1.40

1.40

1.40

2.4KHz

-

-

-

2.15

2.15

2.15

2.15

2.15

1.024MHz

-

-

-

18.70

18.70

18.70

18.70

18.70

0.95

Attenuation dBKm Max. Average 0.90mm² 1.0KHz

-

-

-

0.95

0.95

0.95

0.95

2.4KHz

-

-

-

1.46

1.46

1.46

1.46

1.46

1.024MHz

-

-

-

14.60

14.60

14.60

14.60

14.60

NEXTA (dB) * (minimum) 1KHz

-

-

-

70.00

70.00

70.00

70.00

70.00

1.024MHz (Within Units)

-

-

-

40.00

40.00

40.00

40.00

40.00

1.024MHz (Between Units)

-

-

-

47.00

47.00

47.00

47.00

47.00

* NEXTA at 1.0KHz shall have an average value better than 75dB

For all your cable needs sales@eland.co.uk www.eland.co.uk tel +44 (0)207 241 8787 fax +44 (0)207 241 8700


Copper Trackside Cable