FXPRO
Expand and spread your Security
Fire Detection
FXPRO Expand and spread your Security With the FXPRO multiprotocol control units series, EL.MO. presents a new concept for the fire detection systems, based on a modular structure and on an outstanding flexibility. FXPRO is the heart of this new control units series and manages up to 5 analogue addressable loops with AS or Evolution protocols with the ability to coordinate loops also simultaneously with different protocols. It is possible to add up to 3 FXUP modular units via RS485 to FXPRO in order to manage up to 20 loops. The integration via serial line allows to install FXUP in another place in respect to FXPRO. In this way is possible to manage different places or areas inside the same place in order to reduce the wiring, the costs and the system complexity. The frontal control panel allows the management of the FXPRO control unit and all connected FXUP units. The interface is very clear and any configuration, control, monitoring and command operations are very easy. Thanks to the high flexible structure, FXPRO offers several installation solutions and it is suitable for large size dimensions such as hospitals, shopping malls and hotels.
The union is the safety The connectivity and the possibility to create master-slave structures are addittional key points of the FXPRO analogue-addressable fire detection control units. These features are allowed by FXMASTER supervision panel or directly FXPRO panel. It is possible to realize via RS485 a local control units network (installed in the same or different places) in this way: 1 FXMASTER panel with 4 FX/50, FX/20 or FX/10 control units, or 1 FXPRO with 3 FXUP, FX/50, FX/20 or FX/10 control units. In addition is possible to realize via RS485 a network up to 8 panels choosing by FXMASTER and FXPRO. These panels can manage a control units network composed up to 8 units choosing by FX/10, FX/20, FX/50, FXPRO and FXUP. The panels network repeats and spreads the signals of all system’s devices and allows the control from each panel. Moreover each panel emulate the display and the keyboard of one unit at a time sending to all network devices the EVACUATION, SILENCING and/or RESTORE commands.
2
Fire Detection
Why FXPRO? Up to 20 Loops
Certifications
FX control units are the ideal solution for largescale systems with a high degree of complexity. For instance, matching FXPRO and FXUP allows the management of up to 20 loops
The FX series meets the highest security and quality standards. It is CPR 305/2011 (former CPD 89/106/EEC), EN54-2 and EN54-4 certified
Simple Networks...
... And Complex Networks
The FXMASTER panel can manage up to 4 FX/10, FX/20, FX/50 control units, thus creating a local network of units connected via RS485
On a RS485 bus an 8 panel network may be created between FXMASTER and FXPRO, which may split the management of a network of control units, for a total within the whole system of 8 units among FX/10, FX/20, FX/50, FXPRO and FXUP
Supervision
Logical Equations
Analogue-addressed control units of the FX series may be integrated in the GLOBALPRO supervision software
FX central units enable the definition of logical equations. The outputs of the control unit and of the modules connected to the loop activate after event occurrence (logical or from the system) or patterns. Up to 80 logics and 120 patterns may be set
FXUP
Modular expansion unit without frontal control panel, management of 5 loops optionally AS and Evolution
FXMASTER
Supervision and control panel for FX/10, FX/20, FX/50, FXPRO and FXUP control units
FXPRO
Fire detection control units with frontal control panel, management of 5 loops optionally AS and Evolution
3
FXPRO
FX control units Product code
FXPRO
FXUP
CIFX00200100 CIFX00200101 CIFX00200104 CIFX00200106
CIFX00200200 CIFX00200201 CIFX00200204 CIFX00200206
Analogue-addressable fire detection control units up to 5 loops with control interface Number of addresses for each loop Protocols Number of zones FXUP expansion Fault relay output Alarm relay output Supervised alarm outputs DC24V (LOAD) output General LED indicators LCD display Keypad Management levels Peripheral devices serial lines Extinguishing management Remote assistance Management software PCs & control units network Events log Devices log
Functions
Power supply unit Usable batteries (not included) Power supply Operation temperature Dimensions and weight Protection grade Regulations
4
Analogue-addressable expansion unit up to 5 loops with FXMASTERINT
254 AS using FX/EXP01 board, Evolution using FXEXPEV2 board, IE1 using FXEXPIE, IE2 using FXLOOP 120 Up to 3 additional FXUP units / 2 1 1 freely programmable 3 freely programmable + 1 non-programmable 3 freely programmable 1 Yes / 4 rows with 20 characters each / Built-in, for management and programming / 3 access levels with 10 user passwords associated to the transition from level 1 to level 2 10 installer passwords associated to the transition from level 2 to level 3 1 for management of repeaters, mimic panels and "smart" power supply units Through external unit Using WINFIRE PRO software GLOBALPRO, GPROFIRE and WINFIRE PRO software 16 max 4000 events Graphic visualization of the devices log Management of input and output devices through logic and system events Definition of filters for events log and print management Weekly programmer with day/night function Hour/date definition, with Standard/Daylight Saving Time switch Delayed operating mode Programmable sensitivity thresholds for alarm, pre-alarm and maintenance Device self-acquisition in the loop, with double addresses identification 4A @ DC24V, of which: 1.5A backup battery charge, 0.5A max to the LOAD terminal board for auxiliary devices powering 2 x 26Ah/12V AC230V -5°C / +40°C, 93% Rh W 500 x H 570 x D 190 mm, 16 kg
W 500 x H 570 x D 190 mm, 15 kg IP3X Certified CPR 305/2011 (ex CPD 89/106/CEE certification) EN54-2 e EN54-4
Fire Detection
Analogue addressable detectors
Power supply unit
Range of analogue-addressable smoke temperature detectors for EVOLUTION and AS protocols with many features such as the ability to program the temperature threshold, the low consumption, the OmniView 360° alarm signal and CPR certification.
Power supply unit range among which intelligent power supply unit on RS-485 Serial BUS with voltage network control, voltage supplied, battery voltage, current consumption by the control unit, charge current of the battery and internal temperature of the power supply unit.
Analogue interface modules
Optical-acoustic devices
Wide range of analogue-addressable interface modules, designed for the connection with traditional fire detection devices or sensors. The relay can be used to command magnetic retainer, optical-acoustic fire detection alarm devices, light plaques or to perform different type activation (skylights opening, electrical energy release, gas...) or to acquire states and signals from external devices.
Wide range of alarm detectors such as outdoor self-powered sirens, indoor sirens, optical-acoustic devices (including the new LB3000 panel compliant with the EN54-3 and EN5423 standards), optical-acoustic repeaters to signal the sensor status.
Accessories
Supervision and remote assistance software
Wide range of accessories for the development and expansion of the fire detection system with FX control units: call-points, expansion board for EVOLUTION and AS loop, isolator modules, board of RS-485 serial line interface, LAN interface modules, repeater panels and all is necessary to complete the fire detection system.
Remote assistance supervision and programming software range with maps that allow the direct connection from PC to one or multiples control units, multi-maps architecture, control protection levels and system command, remote assistance and programming.
5 5
FXPRO
Single FXPRO control unit
6
Fire Detection 4 FXMASTER + 1 FXPRO + 3 FXUP
7 7
FXPRO
4 FXMASTER + 2 FXPRO + 6 FXUP
8
Fire Detection 8 FXMASTER and 8 FX series control units
9 9
Notes
10
Fire Detection
11
EL.MO. si riserva il diritto di cambiare le caratteristiche del prodotto senza preavviso C.51.0717.5