Optical Multiband Flame detectors Optical multiband explosion-proof flame detectors are designed to operate in the harshest environments and connect directly to alarm or automatic fire extinguishing systems. IP 329/330-1-2 MSP ultraviolet / infrared (UV / IR) flame detector reacts to both UV and IR flame radiation ensuring accurate and reliable fire monitoring but is immune to arc welding, hot body radiation, lightning or sunlight.

Operating Principle The advanced optical flame detectors are based on monitoring of radiation in two or more optical spectrum bands to prevent false alarm events.

Specific Features The specific design feature of the devices is the build-in test light source for automatic functional test of the sensors. They are used at the industrial enterprises under severe environments.

Main consumers: • • • • • •

• • •

Oil extraction and gas production companies; Oil refining and gas processing companies; Oil and gas storages; Oil and gas pipelines; Fuel terminals and filling stations; Industries (including chemistry, military and energy); Thermal power plants; Energy and transport companies; Strategically important objects.

IP 330-2-2 MSP triple band IR flame detector utilizes advanced technologies to provide the highest level of accuracy available which reduces false alarm events and provides rock-solid performance in any environment.

Specifications Details

Technical data

Operating principle

Optical multiband

Detection distance

Up to 50 m (150 ft) for a gasoline fire

Temperature range

– 40…+85 °С For special requirements – 60…+85 °С

Optical noise immunity

• • •

Response time

< 10 s

Field of view

90°

Output signals

• • •

Power supply

DC 18…32 V

Power consumption • operating mode • alarm mode

2,0 W 4,0 W

Weight

3 kg

Solar light up to 100000 lux Incandescent lamp up to 5000 lux Hot objects up to 500 °С

DC 4…20 mA RS-485 Dry contact relay

• Explosion proof mark 1ExdIICT4Х • Explosion proof type “d” (explosion proof enclosure) • Ingress Protection Rating IP66 Certificate of conformity (explosion proof) RUSSIA № РОСС RU.ГБ05.В04274 (of 08.02.2013) Certificate of conformity (fire proof) RUSSIA C-RU.ПБ34.В.00987 (of 29.08.2012)

+7 (812) 702-07-39 +7 (911) 225-24-22

www.mspex.ru


GSO-R Optical Fixed Gas Detector

Operation Principle

The method of measurement is the Non Dispersive Infrared (NDIR) gas detection.

Specific Features

The GSO-R does not need an oxygen presence for operation. It is tolerant to the presence of nitrogen oxides, carbon oxide, ammonia, sulfur hydrate. The GSO-R tolerates the gas concentration excess up to 100%. Zero correction can be carried out in field. The GSO-R is used at the industrial enterprises under hazardous and severe environments, in a wide temperature range in the presence of chemically aggressive gases.

The fixed optical detector GSO-R is designed for continuous measurements of concentration of methane, propane and other hydrocarbons with the subsequent standard format data transmitting to an upper level control device. The analog output, digital output and built-in relay make it possible to built the GSO-R in any control or immediate protection systems. The length of the RS-485 data links between the fixed detectors and the control device is up to 5000 m. At the request of a customer the MGSO base control unit can be delivered. The MGSO has from 1 to 16 channels via outputs 4-20 mА and from 1 to 128 channels via outputs RS-485. The dimensions of the control unit correspond to 3x19” dimensions of the standard European mount unit designed for 482 x 266 x 132 mm cabinets.

Specifications Details

Technical data

Operating principle

NDIR

Detectable gases

Methane, hydrocarbons, alcohols…

Range of measurements

0…100% LEL

Accuracy

± 5% LEL

Response time

< 10 s

Temperature range

– 40…+85 °С For special requirements – 60…+85 °С

Output signals

Main consumers

• • •

Power supply

DC 18…32 V

Power consumption • operating mode • alarm mode

1,8 W 4,5 W

Weight • stainless steel • aluminum

3,9 kg 6,9 kg

• • • • • • •

Oil extraction and gas production companies; Oil refining and gas processing companies; Oil and gas storages; Oil and gas pipelines; Fuel terminals and filling stations; Industries (including chemistry, military and energy); Thermal power plants; Air, sea, railway and vehicle transportation of oil and gas; Underground installations such as subway etc.

DC 4…20 mA RS-485 (ModBus RTU) Dry contact relay

• Explosion proof mark 1ExdIICT4X • Explosion proof type “d” (explosion proof enclosure) • Ingress Protection Rating IP66 Certificate of conformity (explosion proof) RUSSIA № РОССRU.ГБ05.В04275 (from 08.02.2013) State register № 53085-13

+7 (812) 702-07-39 +7 (911) 225-24-22

www.mspex.ru


GSO-2 and GSO-2SH

Optical and Electrochemical Fixed Gas Detectors The fixed gas detectors GSO-2 and GSO-2SH are designed for continuous measurements of concentrations of combustible and toxic gases with the subsequent standard format data transmitting to an upper level control device.

Specifications Operation Principle The electrochemical or NDIR sensors are used.

Specific Features

GSO-2 and GSO-2SH can be exploited both as standalone detector and as a unit of an emergency protection system MGSO. At the request of a customer the MGSO base control unit can be delivered.

Application scope

Industrial safety in areas of possible occurrence of combustible and toxic gases with hazardous and severe conditions; Environmental monitoring. GSO-2SH can be exploited in the mines as well.

Main consumers • •

• •

Industries (including military and energy); Air, sea, railway and vehicle transportation to ensure gas safety; Metallurgical and chemical enterprises; Structures with hazardous conditions such as canalization, boiler rooms, waste recycling plants…

Details

Technical data

Operating principle

NDIR or electrochemical

Detectable gases:

GSO-2

GSO-2SH

IR sensor (depending on the sensor used)

CO2, CH4, C3H8, ∑CH

CO2

electrochemical sensor (depending of the sensor used)

O2, CO, H2, H2S, NH3, NO2, SO2, Cl2

O2, CO

Sampling

Diffusion

Response time: • IR sensor • electrochemical sensor

30 s 60 s

Temperature range: • IR sensor • electrochemical sensor

– 40…+50 °С – 25 …+50 °С

Output signal

DC 4…20 mA

Power supply

DC 10…32 V

Power consumption

< 2,0 W

Weight

2,5 kg

Explosion proof:

GSO-2

GSO-2SH

Explosion proof mark

1ExdibIICT4X

РВ ExdiblX / 1ExdibIICT4X

Explosion proof type

“d” (explosion proof enclosure) “i” (intrinsic safety)

“d” (explosion proof enclosure) “i” (intrinsic safety)

Ingress Protection Rating

IP54

IP54

Certificate of conformity (explosion proof) RUSSIA

№ РОССRU.ГБ05.В03675 (of 29.06.2011)

№ РОССRU.ГБ05.В03537 (of 11.10.2011)

State register

№ 48338-11

№ 49969-12

+7 (812) 702-07-39 +7 (911) 225-24-22

www.mspex.ru


GSO-Ex Optical and Electrochemical Fixed Gas Detector

Operation Principle In the GSO-Ex the electrochemical or NDIR sensors are used.

Specific Features Zero adjustment and calibration in field are possible. Audio alarm and LED indicators warn about exceeding the preset threshold of gas concentrations.

Application scope Industrial safety in areas of possible occurrence of combustible and toxic gases with hazardous and severe conditions. Environmental monitoring.

GSO-Ex is designed for environmental monitoring and control of the safety on the industry areas. It is equipped with the universal interface for communication with the next level equipment which makes it possible to built the GSO-Ex in any control or immediate protection systems. GSO-Ex can be exploited both as standalone detector and as a unit of an emergency protection system MGSO. At the request of a customer the MGSO base control unit can be delivered.

Specifications Details

Technical data

Operating principle

NDIR or electrochemical IR sensor

Electrochemical sensor

Detectable gases (depending on the sensor used)

CO2, CH4, C3H8, ∑CH

O2, CO, H2, H2S, NH3, NO2, SO2, Cl2

Response time

20 s

60 s

Temperature range

– 40…+75 °С

– 25 …+50 °С

Sampling

Diffusion

Output signal

• • • •

Power supply

DC 10…32 V

Power consumption

< 2,5 W

Weight • stainless steel • aluminum

6,0 kg 3,0 kg

Main consumers • •

• •

Industries (including military and energy); Air, sea, railway and vehicle transport companies; Metallurgical and chemical enterprises; Structure swith hazardous conditions such as canalization, boiler rooms, waste recycling plants…

DC 4…20 mA RS-485 (ModBus RTU) Dry contact relay HART

+7 (812) 702-07-39 +7 (911) 225-24-22

www.mspex.ru


The MGSO Multichannel Gas Analyzer The MGSO gas analyzer is designed to monitor the concentrations of combustible and noxious gases over the industrial area. The MGSO gas analyzer consists of the base control unit and remote fixed detectors GSO-R, GSO-2, GSO-2SH, GSO-Ex. The fixed detectors can be calibrated on a large number of flammable gases and vapors. Operation Principle

In the GSO detectors the electrochemical or NDIR sensors are used.

Specific Features

The GSO detectors are used under hazardous and severe conditions at the industrial enterprises in a wide temperature range in the presence of chemically aggressive gases.

Application scope

Explosion safety for oil and gas facilities; Underground installations such as mines (GSO-2SH), subway etc., Environmental monitoring; Military and aerospace Industries; Sea, railway and vehicle transportation.

Main consumers • • • •

Industries (including military and energy); Air, sea, railway and vehicle transport companies; Metallurgical and chemical enterprises; Structure swith hazardous conditions such as canalization, boiler rooms, waste recycling plants…

The base control unit is designed to correspond to the 3x19” dimensions of the standard European mount unit designed for 482x266x132 mm3 cabinets. It receives the analog (4 – 20 mA) or digital (RS 485 ModBus RTU) signals from the detectors, compares them to the preset thresholds and gives out the control signals for alarm and protection equipment when the preset thresholds of gas concentrations has been exceeded. The MGSO base control unit provides the audible and visual alarm for each measuring channel when the preset thresholds of gases concentrations have been exceeded. The MGSO base control unit should be placed outside the explosion hazardous area. Additional abilities • Three programmable alarm thresholds; • Connection to external emergency protection equipment through a «dry» contacts relays; Power supply 220 V 50 Hz Communication channels: • DC 4…20mA • RS-485 (ModBus RTU) • Dry contact relay • HART Number of connected sensors: • Analog channels (4…20 mA) – from 1 to 16 • Digital channels (RS-485) – from 1 to 128

+7 (812) 702-07-39 +7 (911) 225-24-22

www.mspex.ru


Sigma Ex handheld explosion-proof three-channel gas analyzer Sigma Ex is designed to monitor the concentrations of combustible and noxious gases for providing industrial and ecological safety.

Operating Principle

In Sigma Ex the electrochemical or optical NDIR sensors are used

Sigma Ex can be used for: • Explosion safety for oil and gas facilities; • Monitoring of the environment and industrial areas; • Underground utilities; • Fuel depots; • Sea, railway and vehicle transportation. Sigma Ex provides the audible and visual alarm when the preset thresholds of gases concentrations have been exceeded.

Specific Features

Sigma Ex is equipped with 2 optical sensors and 1 electrochemical sensor

Application scope Monitoring of an air of the residential and industrial areas. Сertification of workplaces. Oil and gas pipelines. Oil and gas production. Livestock farms. Underground engineering networks. Chemical production and storage.

Main consumers • •

Communications companies; Industry (including chemistry, military and energy) and environmental control. Air, sea, railway and vehicle transport companies.

Specifications Details

Technical data

Operating principle

NDIR or electrochemical IR sensor

Electrochemical sensor

Detectable gases (depending on the sensor used)

CO2, CH4, C3H8, ∑CH

O2, CO, H2S, NH3, NO2, SO2, Cl2

Response time

30 s

60 s

Warm up time

10 min

3 min

Temperature range

– 20…+75 °С

– 20 …+50 °С

Sampling

• •

Operating time without accumulator recharge

15 hours

Power supply

DC 3,6 V

Dimensions

195х106х80 мм3

Weight

0,5 kg

Built-in pump Manual sampling device

• Explosion proof mark 1ExibIIBT4 X. • Explosion proof type “i” (intrinsic safety) • Ingress Protection Rating IP54

+7 (812) 702-07-39 +7 (911) 225-24-22

www.mspex.ru


MSP-DELTA

handheld explosion-proof leak detector of combustible gases and freons MSP-DELTA is designed to detects a leak of the combustible gases, freons and other gases for providing industrial and ecological safety. MSP-DELTA makes it possible to find the location of gas leaks at the industrial enterprises, industrial refrigerators, the enterprises of chemical and other industries.

Operating Principle Conductivity of the semiconductor ceramics being at т=400 °C changes when contacting with combustible gases.

Specific Features •

• •

Setting of the sensitivity threshold to exclude the influence of background concentrations; Video and audio alarm when the combustible gases are detected; Flexible probe for sampling.

Application scope Monitoring of the environment and industrial areas; Oil and gas pipelines and storages; Industrial refrigeration systems.

Main consumers • •

• •

Communications companies; Industry (including chemistry, military and energy),environmental control; Fuel terminals and filling stations; Utilities.

Specifications Details

Technical data

Type of sensor

semiconductor

Number of detectable gases

> 40

Detectable gases

Combustible gases, freons, halogens, CO, H2S, NH3, Cl2, H2 and others.

Sensitivity limit

• •

Response time

<3s

Temperature range

– 25…+50 °С

Sampling

Diffusion

Operating time without accumulator recharge

10 hours

Power supply

DC 3,6 V

Dimensions

150х69х28 мм3

Weight

0,18 kg

Combustible gases, freons, NH3 – 0,001% vol. H2 – 0,0001% vol.

• Explosion proof mark 1ExdibIICT4 X. • Explosion proof type “i” (intrinsic safety) • Ingress Protection Rating IP54 Sensor:

• Explosion proof mark ExdllCU • Explosion proof type “d” (explosion proof enclosure)

+7 (812) 702-07-39 +7 (911) 225-24-22

www.mspex.ru


GRIF-1

Handheld non-radioactive detector of explosives, toxic agents and narcotics GRIF-1 belongs to a new generation of IMS spectrometers. It provides you with field-proven detection of the dangerous substances with high sensitivity and reliability. GRIF-1 not only detects but also identifies the microscopic traces of the dangerous substances in approximately 2 – 5 seconds. Operating Principle Ion Mobility Spectrometry (IMC) and nonradioactive ionization source.

Specific Features 2 USB ports to connect USB Flash Drive, auxiliary keyboard, etc. Connection of auxiliary display; User has a possibility to add the new substances to the device memory for identifying them in the future.

Applications •

• • • •

• •

Airports, subways, railways stations and terminals; Customs / border interdiction; Public places and utilities; Military facilities; Stategically important facilities (industrial facilities, bank vaults); Important public events; Nuclear power plants.

GRIF-1 is able to detect a substance in either particle or vapor state, providing a wide range of applications.

Specifications Details

Technical data

Number of the substances in memory

> 100

Detectable explosives

RDX, PETN, TNT, HMX, nitroglycerine and others

Detectable TICs

Phosphorus and organochlorine compounds, ketons, aldehydes, amines, thiols and others

Detectable narcotics

Cocaine, Heroin, THC, Amphetamine and others

Connection to PC

RS 232, RS 485

Sensitivity limit

10-14 g/cm3

Response time

2–5 s

Temperature range

– 10…+40 °С ( – 40…+50 °С for special requirements)

Sampling: • vapor mode • particle mode

Pump Manual

Alarm

Audio and video

Operating time without accumulator recharge

2 hours

Power supply

220 V 50 Hz

Dimensions

385х370х120мм

Weight

6 kg