Page 1

www.seltron.eu

2015

Energy under control

Product CATALOGUE


“We help people save energy in heating.”


Jože Hertiš, univ. dipl. ing Main owner Technical manager

Dear business partner We are pleased to present Seltron’s latest economical heating solutions to you. Our mission statement is: “We help people save energy in heating.” We also implement this in our own working environment. That is why last year we completed the energy renovation of our office building. We have shifted to renewable energy and automated everything with the latest generation of Seltron’s weather-compensated controls. In this way, we have reduced our energy consumption by as much as 73 %. Where has our development lead us? By using the latest technologies, we are now developing the fourth generation of products. The goals and visions for fourth-generation products are wireless access to remote sensors and connecting the regulation system to the Internet. These solutions enable many new possibilities and advantages - for the end users as well as for the installers, service personnel and the overall support environment. For this purpose, we have developed a cloud-based software platform and the necessary applications for smart devices. The entire solution is called SeltronHome. All of this represents the continuation of development, which began over 25 years ago. Although Seltron was founded as a private company in 1990, its roots can be traced back to 1982. In this time, we have become most recognized for the development and production of solar controls and weather-compensated heating controls. Since 2011, we operate in Maribor, on more than 5,000 m2 of advanced production, storage and office space. We are honoured and pleased that the circle of our business partners is constantly expanding. We are particularly proud that we have achieved a higher level of business excellence and that we are trusted by some of the largest and most reputable manufacturers in the industry, such as Danfoss. We kindly invite you to browse through our catalogue and see how our solutions and products can meet your needs. We aim to work with new ambitious business partners with a recognizable vision - partners who provide modern and efficient solutions to save energy and benefit the end users. Partners like you.


PRODUCT RANGE SeltronHome - NEW

10

Seltron Home is a modern heating management solution comprising Seltron heating controllers, a cloud-based software platform and applications for smart devices. These solutions enable many new possibilities and advantages for end users as well as installers, service personnel and the overall supportive environment.

PROMATIC® SGC solar controllers

16

PROMATIC® SGC solar controllers are used for the control of solar systems and in combination with other energy sources. SGC controllers allow selection between up to 63 pre-set hydraulic schemes. Controller set-up and management is extremely easy thanks to Seltron simplicity solutions. Unique solutions, such as a start-up wizard, 14-language support, programming of free relays, interactive help and operation simulation are all built-in as standard.

PROMATIC® AHC - NEW and CMP heating controllers

28

PROMATIC® AHC are compact and simple heating controllers that are installed directly onto the mixing valve. They are distinguished by their compact design, fast installation, ease of use and reliability. Depending on circuit type they can control mixing valve according to room, outdoor or room & outdoor temperature. PROMATIC® CMP is a modern weather-compensated heating controller with touch screen capability. The controller boasts a compact design with a built-in actuator to control the mixing heating circuit. It can function as an independent controller or as an extension for additional heating circuits.

PROMATIC® WDC heating controllers

38

PROMATIC WDC are modern weather-compensated heating controllers. They are designed for room heating with one or two mixing heating circuits, domestic hot water warming with a boiler and solar system and for the control of up to two heat sources. WDC controllers also boast simple operation using Seltron simplicity solutions and can be connected together via BUS connection. ®

PROMATIC® WXD heating controllers PROMATIC WXD are modern weather-compensated heating controllers. Their size of 144 x 96 x 48 mm makes them universally suitable for new heating installations as well as a replacement for existing systems. They are designed to control up to two mixing heating circuits, domestic hot water warming with a boiler and/or solar system and for the control of up to two heating sources. ®

6

50


PROMATIC® KXD boiler controllers

62

PROMATIC KXD boiler controllers are modern and powerful controllers for the control of boiler, domestic hot water warming, alternative heat sources and solar systems. They are designed to control (oil or gas fired) boiler temperature, protect the boiler and control complete heating system. ®

PROMATIC® ACC and SCC constant temperature controllers

74

PROMATIC® ACC constant temperature controllers are used for constant temperature control. They have a built-in actuator to control the mixing valve or the mixing valve and pump. The controller is set-up through a touch sensitive keypad located on the upper side of the controller. PROMATIC® SCC controllers are used for constant boiler return-pipe temperature control and storage tank loading. SCC controllers can be used in all kinds of solid fuel boiler systems as well as in pellet boiler systems. The layered storage tank loading function enables quick energy gain at boiler start-up and thus the quick start-up of the heating system.

PROMIX® AVC actuators

84

PROMIX® AVC actuators are used to control mixing and ball valves. A wide range of actuators is available depending on the rated torque, operation mode, running time and power supply. All actuators are equipped with a clutch and LED signalization of operation.

Room units - NEW

92

RCD is a modern, elegantly-designed in-room unit used to control and display the room temperature in combination with all types of Seltron weather-compensated heating controllers.

T1, ST2R and ST2RDR room thermostats

98

Room thermostats are used to control the temperature in apartment buildings, smaller houses and business buildings or for zone control in large buildings.

Temperature sensors

106

Temperature sensors are available in various configurations depending on the intended use and location of installation.

7


SETUP WIZARD The controller guides you through the first commissioning in 3-, 4- or 5-steps; all other parameters are factory pre-set.

STEP 1

STEP 2

STEP 3 (4)

Select one of the 14 languages.

Select hydraulic scheme.

Select heating curve steepness.

READY

SYSTEM SIMULATION Do you want to test your heating system’s operation? Run the integrated simulation program.

The simulation program is a special function that simulates the temperature measured by the sensors and thus allows the user to test system operation.

8


PC INTERFACE Seltron controllers can be connected to a PC through a dedicated USB interface.

Connecting the controller with a PC enables users to

yy Setup the controller. yy Export / import settings. yy Display system operation. yy Simulate sensors. yy Save settings.

INTERACTIVE HELP Fast and easy access to short manuals, notifications and warnings.

VERSION

WARNINGS

Information about the controller.

Sensors fault, communication errors, etc.

NOTIFICATIONS

DELETE

Information about exceeded maximal temperatures and the activation of safety functions.

Clear Logs.

HELP Short manual.

9


SELTRONHOME Heating controllers

Heating controllers

PROMATIC速 WDC

PROMATIC速 WXD

Wi-Fi Gateway GWD1

Heating controllers

Heating controllers

PROMATIC速 CMP25-2

PROMATIC速 KXD

SELTRONHOME SeltronHome is a modern way of regulating, saving and ensuring comfortable room heating. State-of-the-art technology brings together Seltron heating controllers with a cloud-based software platform and applications for mobile devices and personal computers. These solutions enable many new possibilities and advantages for end users as well as installers, service personnel and the overall supportive environment. Existing users of Seltron controllers can connect them to SeltronHome through the GWD communications interface, while 4th generation (4G) controllers connect to SeltronHome automatically without the need for any additional equipment. The SeltronHome platform also allows the transfer of data for the Selcontrol software suite and other DDC or SCADA systems.

10


SELTRONHOME CLAUSIUS App

Connection between controller and mobile phone.

GWD GATEWAY GWD1 is a Wi-Fi gateway which allows owners of Seltron controllers to use the SeltronHome environment and remote heating management applications. Comunnication interface of the heating controller is connected to the GWD with the cable. The GWD Gateway connects to the household Wi-Fi network and from there to the Internet and the cloud. The SeltronHome software, which is the heart of the solutions, runs in the cloud. The GWD connects to the Internet with the touch of a button or by using a mobile device or computer application.

11


12


CLAUSIUS APPLICATION Clausius is an on-line and mobile application for PCs, tablets and smart phones. It is aimed at the end users of Seltron heating controllers. It allows users to simply and remotely manage and fine-tune their home heating system from anywhere and at any time. The application supports the review and set-up of the requested temperature, time programmes of the heating areas and hot water, the activation of Party, Eco and Holiday functions, and much more. The application also monitors the functioning of the heating system and notifies the user when necessary. For example: “Fill the hopper with pellets”, “Load more logs”, “Clean the boiler”, or when an unusual temperature deviation occurs. The applications currently support Android and iOS devices.

Characteristics of the Clausius application

Simple remote control

Merging heating circles

Transparent, simple and

and heating system

into actual heated areas.

comfortable setting of

management.

time programmes.

Unlimited tailoring to

Free trial of the application

Immediate information on any

one’s personal lifestyle.

before purchase.

malfunctions or deviations.

KELVIN APPLICATION The Kelvin application is used by installers and service personnel to obtain remote data on the heating system status, any potential deviations and operating malfunctions, to monitor the operating parameters, to obtain user help in setting the time programmes, heating curve and similar.

13


For domestic hot water. 14


PROMATIC速 SGC Solar controllers

15


PROMATIC速 SGC Solar controllers HIGHLIGHTS yy Control of up to 65 different hydraulic schemes. yy Measurement and display of gained energy. yy Support for electronic pumps (ErP). yy Remote control via SeltronHome platform. yy Overheating and frost protection.

PROMATIC速 SGC is a modern and powerful controller designed for demanding hydraulic systems. Effectiveness and universality of SGC controller is achieved with a built-in 0 - 10 V and PWM control of the solar circulation pump and the possibility to select between many different pre-set hydraulic schemes. For hydraulic schemes with two storage tanks, different loading strategies are available for optimal usage of the solar energy. The unused output can be freely programmed. PROMATIC速 SGC solar controllers control speed of solar circulation pump and keep constant temperature difference between solar panels and d. h. w. storage tank. This way the maximum efficiency of solar systems can be achieved. SGC solar controllers are performing also a variety of other control and logic functions to ensure an effective operation of many hydraulic systems with solar panels and other energy sources. Integrated solution Seltron simplicity adds a unique and easy note to the controller at start up and use. The 14-language support, simulation of the temperature sensors, graphical presentation of measured temperatures and gained energy offers to user even greater comfort and oversight of the solar system. Large illuminated graphical display allows a clear demonstration of the system operation and all other data.

16


SIMPLICITY SOLUTION

USER FUNCTIONS Provide additional comfort and benefits when using the controller.

One time domestic hot water warming

SELTRONHOME PROMATIC® SGC controllers can be connected into the SeltronHome environment for a comprehensive remote control and operation regulation. Remote access is provided by the Clausius application for the end users and the Kelvin application for installers and servicemen.

The function switches on the water heating instantly.

Holiday mode for the solar system Holiday mode activates cooling down of the storage tank to minimum temperature during night time. Cooling is carried out through solar collectors.

Anti-legionella program *

SETUP WIZARD The controller leads you in 2- steps through the first commissioning; all other parameters are pre-set.

SYSTEM SIMULATION The simulation program is a special function which allows temperature sensor simulation, and thereby enables the user to test the system operation.

INTERACTIVE HELP Fast and easy access to short manuals, notifications, warnings, software version, etc.

The controller ensures the medium is bacteriafree by periodically heating water to 60 °C.

SOLAR SYSTEM PROTECTION The controller has built-in mechanisms that protect solar panels as well as medium and heat storages against overheating or freezing.

PC INTERFACE Through dedicated USB inverter the PROMATIC® SGC solar controller can be connected to a PC. The accompanying Selcontrol software allows setting and monitoring of controller operation using a PC. The solution also operates in the SeltronHome environment.

* The above functions are available only by schemes with oil boiler, electric heather or heat pump.

17


Solar controller PROMATICÂŽ

SGC16H

SGC26H

SGC36HV

SGC67HV

Number of hydraulic schemes

5

22

53

65

Number of collector fields

1

2

2

2

Number of storage tanks

1 l

2 l

3 l

3 l

l

l

l

l

l

l

Controller is "ERP ready" Heat metering with flow sensor impulse type (l/min) Possible measurement of the flow with Vortex flow meter Applicable with classic or pipe solar systems

l

l

l

l

Number of mechanical relays

0

1

1

4

Number of electronic relays

1

1

2

2

Number of PWM/analogue outputs

1

1

2

2

Number of temperature sensors

6

6

6

7

Holiday mode

l

l

l

l

Instant domestic hot water warming

l

l

l

l

Heat metering (kWh)

l

l

l

l

Antilegionella protection*

l

l

l

l

Frost protection

l

l

l

l

Protection of solar system

l

l

l

l

Forced activation of the pump by collectors maximum temperature

l

l

l

l

Collector’s safety shutdown

l

l

l

l

Storage tank protection

l

l

l

l

Anti block function for pumps

l

l

l

l

Display of hydraulic scheme

l

l

l

l

Graphic overview of temperatures and gained energy

l

l

l

l

Logging of settings changes

l

l

l

l

Simulation of system operation

l

l

l

l

Error and high temperature warning

l

l

l

l

Multilingual user interface

l

l

l

l

Simple adjustment of operating modes by selection of hydraulic scheme

l

l

l

l

Graphical adjustable time programs

l

l

l

l

1

2

3

USER FUNCTIONS

FEATURES

HEATING SYSTEM PROTECTION

DATA DISPLAY

SETTINGS AND INSTALLATION

Free programmable outputs Possible installation directly on wall or on DIN rail

l

l

l

l

Easy installation and connection

l

l

l

l

l

l

l

l

REMOTE ACCESS Possibility of connection with PC * Available only by schemes with boiler, electric heater or heat pump.

18


HEAT SOURCE

Solar controller PROMATIC速

SGC16H

SGC26H

SGC36HV

SGC67HV

Solar collectors

l

l

l

l

Solid fuel boiler

l

l

l

l

Boiler with pellet burner

l

l

l

Oil boiler

l

l

l

Combined boiler for liquid and solid fuel

l

l

l

Gas boiler

l

l

l

Heat pump

l

l

l

l

l

l

l

l

l

l

l

l

l

l

l

l

l

l

l

l

Heat accumulator

l

Additional electric heating

REGULATED ELEMENTS

Domestic hot water warming

l

Domestic hot water circulation Heat accumulator warming 1-phase storage tank loading 2-phase storage tank loading

l

l

19


TECHNICAL DATA SGC16H

SGC26H

SGC36HV

Power supply

230 V ~, 50 Hz

Consumption

< 4 VA

Consumption in standby

SGC67HV

max. 0,5 W 7 x temperature (Pt 1000)

6 x temperature (Pt 1000)

Inputs

1 x pulse input X

1 x Grundfos Direct sensors VFS

1 x triac for speed control (R2) 1 x PWM or analogue 0÷10 V (Y2)

2 x triac for speed control (R2, R3) 2 x PWM or analogue 0÷10 V (Y2, Y3)

Additional input

Outputs

Relay output

X

Clock backup

Battery CR2032 (Li - Mn) 3 V

Clock accuracy

+/- 1 s (24 h) at 20 °C

Degree of protection

IP20 / EN60529

Safety class

I according to EN 60730-1

Operation type

1B acc. to EN 60730-1

Controller housing

ASA - thermoplastics

Dimensions (w × l × h)

113 x 163 x 48 mm

Ambient temperature

0 ÷ 40 °C

Storage temperature

-20 °C ... +65 °C

Weight Package unit

20

5 (1) A ~, 230 V ~

399 g

401 g

404 g 12 pcs

412 g


OVERVIEW OF GAINED ENERGY

SIMPLE CONTROLLER SETTING AT THE FIRST BOOT

SGC controllers provide rough and

At the first boot the controller requires only two-step setting.

precise measurement of the gained solar energy. To obtain a rough measurement,

STEP 1

STEP 2

the maximum media flow reading from

Select one of the 14

Select the preferred hydraulic

languages available

scheme to set the controller’s

on the user interface.

operation mode.

a mechanical gauge should be input into the controller settings. For precise energy measurement the flowmeter with impulse generator or vortex flow

216

sensor VFS should be installed in the T1

solar circuit. Tc R2

T3 T2

R1

ay kd

ee h/w kW

CONTROL OF ELECTRONIC REGULATED PUMPS Up to two efficient solar pumps and one mechanical

Graph of gained energy by day.

or electronic flow gauge can be connected to the PROMATIC® SGC controllers. In addition, the PROMATIC® SGC controllers have 0-10 V and PWM signal for control of up to two ErP pumps.

th on

h/m kW

CONTROLLER MOUNTING Graph of gained energy by day.

The PROMATIC® SGC solar controller is mounted on the wall in a boiler room.

ear h/y kW

Graph of gained energy by year.

21


HYDRAULIC SCHEMES The illustrated hydraulic schemes are supported in the following controllers: PROMATIC速 SGC16H, SGC26H, SGC36HV and SGC67HV. 201

202

204

203

T1

T3

Tc R2

R2

Solar collectors, d. h. w. storage tank.

T4

T1 R2

T3

T1

T2

T1 T2

T2

Solid fuel boiler, d. h. w. storage tank.

D. h. w .storage tank, electric heater.

R2

T3

Solid fuel boiler, heat accumulator.

205

R2 T1 T2

Heating support with heat accumulator.

The illustrated hydraulic schemes are supported in the following controllers: PROMATIC速 SGC26H, SGC36HV and SGC67HV. 212b

212c

T1

213

214

T1

R1

T3

T1 R2

T3 R2

T2

Liquid fuel boiler, d. h. w. storage tank.

T1

Tc R2

T2

R1

Heat pump, d. h. w. storage tank.

Solar collectors, swimming pool.

216

217

215

T3 R1 T2

Tc R2

T2

Solar collectors, d. h. w. storage tank, backup heating with electric heater. 218

T1 T3

T3 R1 T2

T1 R2

Tc R2

Solid fuel boiler, d. h. w. storage tank, backup heating with electric heater.

2

T3 T2

T1

R2

R1

Solar collectors, d. h. w. storage tank, heat take away.

1 R1

T2

D. h. w. storage tank, thermostat for heating R2, thermostat for cooling R1.

220

219

R2

R1 T1

220b

T2

Heating support with heat accumulator, backup heating with electric heater. 220c

T1

R1 T2

T1

R2

T3

Solid fuel boiler, d. h. w. storage tank.

T2 R2

T2

Liquid fuel boiler, d. h. w. storage tank.

1

T4

T1 T2

R1

225

T1 R1 T4 T2

T1 T3

Solar collectors, heating support with heat accumulator.

22

2

T1 T3

224

2

T1

T4 T2

Heat pump, heat accumulator.

T5 T3

R1

Solar collectors, d. h. w. storage tank, solid fuel boiler.

Tc R2

T4

Solar collectors, two d. h. w. storage tanks - switchover.

T2

223

T1

1

R2

Pellets boiler, heat accumulator.

T1

Tc R2

T3

R1

T3

222

221

Tc R2

T4

T1

T3

T1

R1

R2

R1

Tc

R2

T2

Solar collectors east / west orientation - switchover, d. h. w. storage tank.

Tc R2

T4

1

2 T2

R1

T3

Solar collectors, two d. h. w. storage tanks, heat transfer to storage tank 2.


HYDRAULIC SCHEMES The illustrated hydraulic schemes are supported in the following controllers: PROMATIC速 SGC36HV and SGC67HV. 231b

231

T1

T1

T4

Tc R2

231c

T3

T3

Solar collectors, d. h. w. storage tank, solid fuel boiler.

T1

T1

T4

Tc R2

R3

T2

231d

Tc R2

R3

T2

Solar collectors, d. h. w. storage tank, liquid fuel boiler.

232

T1

R1

T4

Tc R2

R3

T2

T4

Solar collectors, d. h. w. storage tank, heat pump.

232b

T3

R1 T2

R3

Solar collectors, d. h. w. storage tank.

233

232c T1

T1

T1

1

Tc R2

2

T4

T5

R3

2

1

Tc R2

T3

T2

T1

T5 T4

R3

Solar collectors, d. h. w. storage tank - backup heating with electric heater, solid fuel boiler.

1

2

T4

1

T5

T2

Tc

T3

R3

Solar collectors, d. h. w. storage tank / heat accumulator - switchover, solid fuel boiler.

2

T4

R2

T5

T2

T3

R3

Solar collectors, two d. h. w. storage tanks - switchover, heat accumulator.

233c

233b

Solar collectors, two d. h. w. storage tanks - two pumps, heat accumulator.

234

234b

T1

T1

2

1 Tc

R1

Tc R2

R1

T3

T2

1

T4 T2

R2

T3

Tc

R1 T5

T4 R1

R2

R1

T3

T2

Tc

Tc R2

T4

T4

T4 R3

R1

T3

R3

R3

T1

T1

2

T2

T3

T2 R1

Solar collectors, d. h. w. storage tank / heat accumulator - switchover, solid fuel boiler.

Solar collectors, d. h. w. storage tank, heat accumulator, solid fuel.

235 T1 T3

1

236

2

R2

Tc

T1 T3

1 T4

R3

T4 Tc

Tc R2

T2

Solar collectors east / west orientation - two pumps, d. h. w. storage tank.

239

238

1

T4

1

2 T2

R3

Solar collectors, two d. h. w. storage tanks - heat transfer into the d. h. w. storage tank 2.

2

T1

1

Tc R2

T3

240

2

T5 T2

T3

R3

T4

Solar collectors, d. h. w. storage tank. Two separate circuits.

241

T1

T1

Solar collectors, d. h. w. storage tank / swimming pool - two pumps.

T1

R3

R2

R3

237

2

T2

Solar collectors east / west orientation - switchover, d. h. w. storage tank.

Solar collectors, d. h. w. storage tank / swimming pool - switchover.

R2

243

T1

T1 R3

R3 T3 R1 T2

Tc R2

T4

Tc R2

Solar collectors, d. h. w. storage tank, switchover top/bottom, backup heating with electric heater. 243b

T2

T1

T4 R1

Tc R2

T3

Solar collectors, heating support with heat accumulator.

T2

T1

R3

R3

Solar collectors, d. h. w. storage tank, solid fuel boiler.

243c

T3

Tc

T3

T3

R2

T4 T2

Solid fuel boiler / solar collectors switchover, d. h. w. storage tank.

244

245

T1

Tc

T3 R3

R2

T4 T2

Liquid fuel boiler / solar collectors switchover, d. h. w. storage tank.

R1

Tc R3

R2

T4 T2

Heat pump / solar collectors switchover, d. h. w. storage tank.

T1

R3-

R2

T2

R1+

T4 T1 T2 R2

R1+

T3

R3-

Control of the swimming pool warming.

Solid fuel boiler, return pipe temperature control.

23


HYDRAULIC SCHEMES The illustrated hydraulic schemes are supported in the following controllers: PROMATIC速 SGC36HV and SGC67HV. 246

247

246b

247b

T1 T1

T1 R3

R1 R1

T3

Tc R2

T5

R3

1

2

T2

T4

1

2

T2

T4

Solar collectors, reversible transfer of heat between the main and auxiliary heat accumulator - two pumps.

T1 T3

1 T5

1

2

3 T3

T2

1

Solar collectors east / west orientation - two pumps, two d. h. w. storage tanks - switchover.

T5

1 T4

R2 Tc

R3

Solar collectors east / west orientation - switchover, two d. h. w. storage tanks - switchover.

T4

Solar collectors, three d. h. w. storage tanks - switchover.

2

2

T2

3 T3

R3

R1 Tc

R2

2

T2 R1

248c T1 T3

1

R1

T4

R1

T5

1

Tc R1

T4

Solar collectors, three d. h. w. storage tanks - three pumps.

2

2

T2 Tc

R2 R3 R1

248b

2

R3

R2

Tc

T5

248 T1 T3

T5

1

R3

T3

Tc R2

Solar collectors, reversible transfer of heat between the main and auxiliary heat accumulator - switchover.

1

T1

T5

2 T4

T2 R3

Solar collectors east / west orientation - switchover, two d. h. w. storage tanks - two pumps.

The illustrated hydraulic schemes are supported in the following controllers: PROMATIC速 SGC67HV. 261

262

261b

262b T1

T1

T4

T5

T6 R3

T1

T3

R4+

T1

T3

Tc R2

T6 R3

R4+

T4 Tc R2

R1 T6 R3

R4+

T2

R5-

R5-

T5

T4

T5

T2

R2 R1

R4+

T4

T5 T2

R2 T6 R3

T2

R5-

R5-

Solid fuel boiler, heat accumulator, d. h. w. storage tank.

Pellets boiler, heat accumulator, d. h. w. storage tank.

263

Tc R2 R4+

T3

T4

T5 R1

T6 R3

T2

R5-

Solid fuel boiler, heat accumulator / d. h. w. storage tank - switchover, solar collectors.

T3

T4

Pellet boiler, heat accumulator / d. h. w. storage tank - switchover, solar collectors.

R5+

R4-

R6-

T3

T6

Solid fuel boiler, constant temperature return-pipe regulation, heat accumulator - layered filling.

24

R3+

R1

T4

R3+

R5+

R4-

R6-

T3

T6

Pellet boiler, constant temperature return-pipe regulation, heat accumulator - layered filling.

T2 R2

R3+

T3

R4-

R4-

Solid fuel boiler, heat accumulator, d. h. w. return-pipe regulation.

Pellet boiler, heat accumulator, d. h. w. return-pipe regulation.

293

T5 T6

T4

T1

T5

T2 R2

T4

T1 R1

T3

292b

T1

T5

R3+

T2 R2

T2 R6

292

T2 R2

T4

T1

Tc R2 R4+ R5-

R6

T1

291b

T1

T4 T6 R3

Pellets boiler, heat accumulator, solar collectors.

291

263b

T1

T5

Solid fuel boiler, heat accumulator, solar collectors.

T2 R2 R3+

R5+

R4-

R6-

T3

Solid fuel boiler, constant temperature return-pipe regulation, two heat accumulators - layered filling.

293b

T1 R1

T4 T2 R2 R3+

R5+

R4-

R6-

T5 T3

T6

Pellet boiler, constant temperature return-pipe regulation, two heat accumulators - layered filling.


ORDERING CODES Solar controller PROMATIC® SGC16H Code: 2SGC16H00-010

Solar controller PROMATIC® SGC16H incl. 3xTF/Pt sensor Code: 2SGC16H30-010

Solar controller PROMATIC® SGC26H Code: 2SGC26H00-010

Solar controller PROMATIC® SGC26H incl. 4xTF/Pt sensor Code: 2SGC26H40-010

Solar controller PROMATIC® SGC36HV Code: 2SGC36HV00-010

Solar controller PROMATIC® SGC36HV incl. 4xTF/Pt sensor Code: 2SGC36HV40-010

Solar controller PROMATIC® SGC67HV Code: 2SGC67HV00-010

Solar controller PROMATIC® SGC67HV incl. 5xTF/Pt sensor Code: 2SGC67HV50-010 Surface sensor VF/Pt Code: 1VFPT-000 Immersion sensor TF/Pt Code: 1TFPT-000 Flowmeter SVC25 Code: 1SVC25+NN0

25


Touch me.

26


PROMATIC速 AHC PROMATIC速 CMP Compact heating controllers

27


PROMATIC® AHC and CMP Compact heating controllers HIGHLIGHTS yy 14-language support. yy Mixing heating circuit control. yy Touch screen display (CMP25-2). yy Prewired controller for »Plug & play« installation. yy Simple setup. yy Fits on most of the mixing valves on the market.

PROMATIC® AHC controllers are intended to control mixing circuit temperature according to room or outdoor or booth temperature.

yy AHC20 controller is a thermostatic (room sensor) controller of mixing circuit. yy AHC21 controller is weather compensated (outdoor sensor) controller of mixing circuit. yy AHC22 controller is a universal controller and has a possibility to choose the operation mode with outdoor or room sensor. Setup of controller is done with touch sensitive keypad on the cover of the controller. Display is used to indicate actual temperatures and to setup the controller. PROMATIC® CMP25-2 is the first compact controller with touch screen with a built-in actuator. It has an innovative and unique concept and user friendly interface. PROMATIC® CMP25-2 is weather compensated heating controller designed for a single mixing heating circuit control or for system expand via BUS connection. With Seltron simplicity solutions, setup and settings can be easily managed by using the touch-screen interface and following the instructions in the language of your choice. With »Plug & Play« installation, mounting directly to the mixing valve is simple and fast.

28


SIMPLICITY SOLUTION

USER FUNCTIONS Party operation mode * Party operation mode is selected to extend daily or comfort mode of space heating. You can also set the time of the Party operation mode.

SELTRONHOME PROMATIC速 AHC and CMP controllers can be connected into the SeltronHome environment for a comprehensive remote control and operation regulation. Remote access is provided by the Clausius application for the end users and the Kelvin application for installers and servicemen.

SETUP WIZARD The CMP25-2 controller leads you in 5- steps through the first commissioning; all other parameters are pre-set.

INTERACTIVE HELP Fast and easy access to short manuals, notifications, warnings, software version, etc.

ECO operation mode *

ECO

ECO function allows heating at a lower or energy saving temperature. You can also set the time of the Eco operation mode. Holiday operation mode * By pressing the HOLIDAY operation mode the heating is set at a specific energy saving temperature until the selected date.

PROTECTIVE FUNCTIONS The built-in mechanisms protect the heating system against freezing, while additional integrated functions ensure start-up of a circulation pump and opening of a mixing valve when either the pump of the valve have been inactive for a longer period of time.

PC INTERFACE Through dedicated USB inverter the PROMATIC速 AHC and CMP controllers can be connected to a PC. The accompanying Selcontrol software allows setting and monitoring of controller operation using a PC. The solution also operates in the SeltronHome environment.

* The above functions are available with AHC controllers only when connected to a digital room unit.

29


Compact heating controller PROMATIC® Number of hydraulic schemes Heating and cooling

AHC20

AHC21

AHC22

CMP25-2

1 l

1 l

1 l

2 l

l

l

l

l

l

Weather compensated control of the heating system Operation with room temperature sensor

l

Maximal stand-pipe temperature limitation for floor heating

l

l

l

l

Number of mechanical relays

1

1

1

1

Number of electronic relays

2

2

2

2

Number of temperature sensors

2

2

2

BUS connection with other controllers

1

1

1

4 l

FEATURES

USER FUNCTIONS Weekly program timer

If a room unit is connected

l

Function PARTY

If a room unit is connected

l

Function ECO

If a room unit is connected

l

HOLIDAY mode

If a room unit is connected

l l

Automatic switchover winter / summer HEATING SYSTEM PROTECTION Frost protection

l

l

l

l

Anti block function for pumps and valves

l

l

l

l

DATA DISPLAY Prikaz hidraulične sheme

l

Grafički prikaz temperatura i dobivene energije

l

Logging of settings changes

l

Error and high temperature warning

l

SETTINGS AND INSTALLATION Multilingual user interface

l

Simple interactive programming of interval working

l

Plug & Play-Installation

l

l

l

l

Installation sets for many mixing valves

l

l

l

l

Error diagnostics and automatic switchover to the alternative operating mode

l

l

l

l

Possibility of connection with PC

l

l

l

l

SeltronHome remote control with Smart phone or Tablet

l

l

l

l

REMOTE ACCESS

30


Compact heating controller PROMATIC速

AHC20

AHC21

AHC22

CMP25-2

Solar collectors

HEAT SOURCE

Solid fuel boiler Boiler with pellet burner Oil boiler Combined boiler for liquid and solid fuel Gas boiler Heat pump Heat accumulator

REGULATED ELEMENTS

Additional electric heating Control of constant stand- or return- pipe temperature

l

Mixing heating circuit

l

l

l

l

Radiators

l

l

l

l

Floor heating

l

l

l

l

31


TECHNICAL DATA AHC20

AHC21

AHC22

Power supply

230 V ~, 50 Hz

Consumption

< 4 VA

Consumption in standby

max. 0,5 W

Load on pump output (R1)

4 (2) A / 230 V~

Torque

6 Nm

Degree of protection

IP42 acc. to EN 60529

Safety class

I acc. to EN60730-1

Operation type

1B acc. to EN 60730-1

Temperature sensor type

Pt1000

Mixing valve control

PC - thermoplastics

Dimensions (w× l × h)

84 × 101 × 88 mm

Ambient temperature

0 ÷ 40 °C

Storage temperature

-20 ÷ 65 °C

Package unit

32

Pt1000 or KTY10

3-point PID

Controller housing

Weight

CMP25-2

678 g

678 g

678 g 12 pcs

84 × 105 × 100 mm

827 g


INSTALLATION Controller can also be mounted rotated for 180 째, with automatic adjustment of

LED SCREEN AND CAPCITIVE TOUCH INTERFACE Keypad is touch sensitive and resistant to moisture and dust.

the display orientation.

TOUCH SCREEN CMP25-2 has advanced user interface by means of touch sensitive screen.

BUS CONNECTION

COMPATIBLE WITH MIXING VALVES

CMP25-2 controllers can be connected into a unique heating system by means of BUS connection. Only one outdoor sensor is required for operation of controllers in BUS network. For easy and quick connection of controllers a 10-pole connector is used.

AHC and CMP25-2 controllers can be mounted on a wide range of mixing valves from different manufacturers. For this purpose various installation sets are available.

33


HYDRAULIC SCHEMES The illustrated hydraulic schemes are supported in the following controllers: PROMATIC速 AHC20, AHC21 in AHC22. AHC20

AHC22

AHC21

or

Mixing heating circuit, room temperature control.

Mixing heating circuit, weather compensated control.

Mixing heating circuit, room temperature or/and weather compensated control.

The illustrated hydraulic schemes are supported in the following controllers: PROMATIC速 CMP25-2. TR

T2

360

T3 R1

BUS

TR

T3 R1

360b

T4

T4

Mixing heating circuit,weather compensated control.

34

Mixing heating circuit, weather compensated control, system expand.


MIXING VALVE INSTALLATION SETS

ORDERING CODES Controller PROMATIC® AHC20 incl. 1xTF/Pt and 1xDD2+ Code: 1AHC2011-040

Sets for controller PROMATIC® CMP25-2 Controller PROMATIC® AHC21 incl. 1xTF/Pt and 1xAF/Pt

CODE

MANUFACTURER

1CMPMSA+NN0

Esbe, Afriso, WIP, Hora, Brv, Acaso, Ivar, Seltron, IMIT, IMP

1CMPMSB+NN0

Centra ZR/DR

1CMPMSC+NN0

Centra DRU

1CMPMSD+NN0

Siemens VBI, VBF

1CMPMSE+NN0

Esbe VRG

Controller PROMATIC® CMP25-2 incl. 1xAF/Pt, 1xTF/Pt and 1xVF/Pt

1CMPMSF+NN0

Firšt

Code: 2CMP2510150-010

1CMPMSG+NN0

Honeywell V5442, V5433

1CMPMSH+NN0

PAW - K32, K33, K34

Sets for controller PROMATIC® AHC CODE

MANUFACTURER

1ASCAVMSA000+NN0

Esbe, Seltron, Somatherm, Acaso, IVAR, WIP, PAW, BRV, IMIT, Hora, Barberi, Olymp, Hoval

1ASCAVMSG000+NN0

Esbe VRG

1ASCAVMSB000+NN0

for 10Nm+ Esbe, Seltron, Somatherm, Acaso, IVAR, WIP, PAW, BRV, IMIT, Hora, Barberi, Olymp, Hoval

Code: 1AHC2112-040 Controller PROMATIC® AHC22 incl. 1xTF/Pt Code: 1AHC2210-040

Surface sensor VF/Pt Code: 1VFPT-000 Immersion sensor TF/Pt Code: 1TFPT-000 Outside sensor AF/Pt Code: 1AFPT-000 Room unit RCD1 Code: 1RCD1-040 Room unit RCD1P Code: 1RCD1P-040 Room unit RCD2 Code: 1RCD2-040

1ASCAVMSC000+NN0

Centra ZR/DR

Room unit RCD2P

1ASCAVMSD000+NN0

Centra DRU

Code: 1RCD2P-040

1ASCAVMSE000+NN0

Siemens VBI, VBF

1ASCAVMSF000+NN0

Wita, Meibes

1ASCAVMSH000+NN0

Firšt

1ASCAVMSI000-NN0

Honeywell V544, …, V543

1ASCAVMSJ000-NN0

Paw K32, K33, K34

1ASCAVMSK000+NN0

Danfoss HRB, HFE, HRE

35


Made for warmth. 36


PROMATIC速 WDC Heating controllers

37


PROMATIC® WDC Heating controllers HIGHLIGHTS yy Control of up to 52 different hydraulic schemes. yy Control up to two heat sources. yy Control of up to two mixing circuits. yy Solar controller for d. h. w. warming. yy Party, Eco, Holiday and One-time domestic hot water warming functions.

yy 14 language support.

PROMATIC® WDC is a modern weather compensated heating controller with one or two mixing heating circuits, for domestic hot water warming with boiler and solar system and up to two heat sources. WDC is designed for demanding installations and allows user to choose among fifty-two pre-set hydraulic schemes. For a quick and easy start, a start-up wizard is installed, that guides user through the controller setting in only three to four steps. The controller can be switched to simulation mode, where you can simulate the temperatures of individual sensors and monitor the controller’s response.

38


SIMPLICITY SOLUTION

USER FUNCTIONS Party operation mode Party operation mode is selected to extend daily or comfort mode of space heating. You can also set the time of the Party operation mode.

SELTRONHOME PROMATIC® WDC controllers can be connected into the SeltronHome environment for a comprehensive remote control and operation regulation. Remote access is provided by the Clausius application for the end users and the Kelvin application for installers and servicemen.

ECO operation mode

ECO

ECO function allows heating at a lower or energy saving temperature. You can also set the time of the Eco operation mode.

One time domestic hot water warming The function switches on the water heating instantly.

Holiday operation mode

SETUP WIZARD The controller leads you in 3- or 4- steps through the first commissioning; all other parameters are pre-set.

By pressing the HOLIDAY operation mode the heating is set at a specific energy saving temperature until the selected date.

Anti-legionella program The controller ensures the medium is bacteriafree by periodically heating water to 60 °C.

SYSTEM SIMULATION The simulation program is a special function which allows temperature sensor simulation, and thereby enables the user to test the system operation.

HEATING SYSTEM PROTECTION The controller ensures periodical start-up of pumps and valves during inactive period as well as protection of the solar panels, and the heater against overheating or freezing.

INTERACTIVE HELP Fast and easy access to short manuals, notifications, warnings, software version, etc.

PC INTERFACE Through dedicated USB inverter the PROMATIC® WDC weather compensted controllers can be connected to a PC. The accompanying Selcontrol software allows setting and monitoring of controller operation using a PC. The solution also operates in the SeltronHome environment.

39


Heating controller PROMATIC速

WDC10B

WDC10

WDC20

7 l

17 l

52 l

max. 1 1 1

max. 2 1 1

max. 2 1 2 l

Control of 2-stage burner

l

l

l

Max. number of room units

2

2 l

2 l

Function for floor drying

l

l

l

Number of mechanical relays

6

6

7

Number of electronic relays

0

1

1

Number of temperature sensors

7 l

7 l

7 l

Function PARTY

l

l

l

Function ECO

l

l

l

HOLIDAY mode

l

l

l

Instant d.h.w. warming

l

l

l

BOOST function for room heating

l

l

l

Antilegionella protection

l

l

l

Frost protection

l

l

l

Overheating protection for boiler, collectors and storage tank

l

l

l

Anti block function for pumps and valves

l

l

l

Display of hydraulic scheme

l

l

l

Display of measured temperatures

l

l

l

Logging of settings changes

l

l

l

Simulation of system operation

l

l

l

Error and high temperature warning

l

l

l

Multilingual user interface

l

l

l

Simple adjustment of operating modes by selection of hydraulic scheme

l

l

l

Graphical adjustable time programs

l

l

l

Free programmable outputs

l

l

l

Possible installation directly on wall or on DIN rail

l

l

l

Easy installation and connection

l

l

l

Remote activation via telephone

l

l

l

Possibility of connection with PC

l

l

l

SeltronHome remote control with Smart phone or Tablet

l

l

l

Number of hydraulic schemes Heating or cooling Number of heating circuits - of which direct circuits - of which mixing circuits Switching between two heating sources

Solar pump speed control

BUS conection with other controllers

FEATURES

USER FUNCTIONS

HEATING SYSTEM PROTECTION

DATA DISPLAY

SETTINGS AND INSTALLATION

REMOTE ACCESS

40


Heating controller PROMATIC速

WDC10B

Solar collectors

REGULATED ELEMENTS

HEAT SOURCE

Solid fuel boiler

l

WDC10

WDC20

l

l

l

l l

Boiler with pellet burner Oil boiler

l

l

l

Combined boiler for liquid and solid fuel

l

Gas boiler

l

Heat pump

l

Heat accumulator

l

l

l

Additional electric heating

l

l

l

Direct heating circuit

l

l

l

Mixing heating circuit

l

l

l

Radiators

l

l

l

Floor heating

l

l

l

Heat accumulator warming

l

l

l

Domestic hot water circulation

l

l

l

Switching between direct heating circuit and domestic hot water

l

l

l l

Switching between two heat sources Control of constant stand- or return- pipe temperature 1-phase storage tank loading

l

l

l l

41


TECHNICAL DATA WDC10B

WDC10

Power supply

230 V ~ , 50 Hz

Consumption

< 4 VA

Consumption in standby

max. 0,5 W

Relay output

4 (1) A ~, 230 V ~

Triac output

1 (1) A ~, 230 V ~

Degree of protection

IP20 according to EN 60529

Safety class

I according to EN 60730-1

Operation type

1B acc. to EN 60730-1

Temperature sensor type

Pt1000 or KTY10

Mixing valve control

3-point PID

Controller housing

ASA - thermoplastics

Dimensions (w × l × h)

113 x163 x 48 mm

Ambient temperature

0 ÷ 40 °C

Storage temperature

-20 °C ... +65 °C

Weight Package unit

42

WDC20

412 g

412 g 12 pcs

419 g


SELF DIAGNOSTICS REPORTS

HEAT CURVE SETTINGS 110 105

In case of exceeding the maximum temperature or activation of protection function, the controller indicates the event

100 95

floor heating

0,2 - 0,8

wall heating

0,6 - 1,0

radiator heating

0,8 - 1,4

80

S=1,6

65

S=1,4

70

S=1,2 S=1,0

60

exceeded or if the protection function is

55

turned off, an illuminated symbol indicates

45

notifications log.

S=2,2 S=1,8

If the maximum temperature is no longer

key to open the

Setting range

85

75

Help

Heating system

S=2,0

90

with flashing symbol “i” on the display.

a recent event. Press

S=2,6 S=2,4

S=0,8

50

S=0,6

40

S=0,4

35 30

S=0,2

25 20

20

15

20

5

0

-5

-10

-15

-20

With adjustment of the heat curve steepness, the controller is tuned with the building. For optimal controller operation, the right setting of the heat curve steepness is very important.

BUS CONNECTION BUS

BUS

In the event of sensor failure, pump error or flow sensor error, the controller indicates the failure with flashing symbol “!” on the display. If the issue is resolved or no longer present, an illuminated symbol indicates a recent notification. Press the warnings log.

Help

key to open

Using the BUS-connection, it is possible to establish a network of WDC controllers.

CONNECTION OF ROOM UNITS

1

2

1

2

7 GND

Up to two room units can be connected to a controller.

43


HYDRAULIC SCHEMES The illustrated hydraulic schemes are supported in the following controllers: PROMATIC速 WDC10B, WDC10, WDC20. 401

T2

T4 R2 R3+ R4-

T3

401b

T2

R6 R5

T4 R2 R3+ R4-

T3 T6

401c

T2

T4 R2 R3+ R4-

R6 R5

T3

T6

401d

T2

T4 R2 R3+ R4-

R6 R5

T6

R6 R5

T6

R1 T5

T5

T5

Oil boiler, mixing circuit, d. h. w. storage tank.

Solid fuel boiler, mixing circuit, d. h. w. storage tank.

Heat accumulator, mixing circuit, d. h. w. storage tank. 401e

402

T2

T5

System without boiler - mixing circuit, d. h. w. storage tank.

403

T2

BUS

T4 R2 R3+ R4-

R2

R6 R5

R6

T3

T6

R5

R2 R5

T3

T6

R1

R1

System expand - mixing circuit, d. h. w. storage tank.

T6

R4

T5

T5

R6 R3

T5

Oil boiler, direct circuit, d. h. w. storage tank.

Oil boiler, direct circuit, d. h. w. storage tank.

The illustrated hydraulic schemes are supported in the following controllers: PROMATIC速 WDC10, WDC20. 404

T2

404b

T2

T4 R2 R3+ R4-

T3

R7

R5

T4 R2 R3+ R4-

T3 T5

R1

Oil boiler, mixing circuit, d. h. w. storage tank, solar collectors.

404f

T4 R7 R2 R3+ R4-

T5

T5

T3 R6

T6

Heat accumulator, mixing circuit, d. h. w. storage tank, solar collectors.

T1

R7

R5

R6

404e

T2

T4 R2 R3+ R4-

T3

T5 T6

404d

T2

T1

R7

R5

R6

T6

404c

T2

T1

T1

Solid fuel boiler, mixing circuit, d. h. w. storage tank, solar collectors.

405

T2

R6

T6

Heat accumulator with built-in storage tank, mixing circuit, solar collectors.

406

T2

BUS

T1

T1 T4 R2 R3+ R4-

T4 R7 R2 R3+ R4-

T5 R5 R1 T6

T3

R2

R7

R5

T6

Heat accumulator with built-in d. h. w. storage tank, mixing circuit, auxiliary heating with electricity, solar collectors. 407

T2

T6

System expand - mixing circuit, d. h. w. storage tank, solar collectors.

407b

T2 T1

1

R6 T3

T4 R2 R3+ R4-

2

1

R6

R7 R5

T6

R1

T3

T4 R2 R3+ R4-

2

R5

T5

R8* T5

R1 T6

R6

* WDC20

Oil boiler, mixing and direct circuit d. h. w. storage tank.

44

Oil boiler,direct and mixing circuit, d. h. w. storage tank, solar collectors.

R2 R3

T3

T5 R1

R6

R7

R7

R5

T3

T5

R6

T1

T1

R6

Oil boiler, direct circuit, d. h. w. storage tank, solar collectors.

R1

R4

T5 T6

R6

Oil boiler, direct circuit, d. h. w. storage tank, solar collectors.


HYDRAULIC SCHEMES The illustrated hydraulic schemes are supported in the following controllers: PROMATIC速 WDC20. 408

T2

T4 R2 R3+ R4-

T6 R8

R1

408b

T2

T4 R2 R3+ R4-

R1 R7

T6

R5

T3

R7

T4 R2 R3+ T3 R4-

T6

R5 T5

T5

T3

409

T2

T4 R2 R3+ R4-

R1

R7

T6

R5

T3

T5

R1

R8

409b

T2

R7 R5 T5

R8

R8

Wood boiler, oil boiler, mixing circuit, d. h. w. storage tank. 410

T2

T4 R2 R3+ R4-

T6 T3 R1

R8

Wood boiler, gas boiler, mixing circuit, d. h. w. storage tank. 410b

T2

T4 R2 R3+ R4-

R1 R7

T6

R5

T3 T5

T1

410c

T2

R7

R7

T3

T6

T5

Heat accumulator, gas boiler, mixing circuit, d. h. w. storage tank. 411

T2

T4 R2 R3+ R4-

R5

T5

R5 T1

R8

Heat accumulator, oil boiler, mixing circuit, d. h. w. storage tank.

T4 R2 R3+ T3 R4-

T6

R1

T1

R8

R7 R5 T5

R1

R8

Heat accumulator, oil boiler, mixing circuit, d. h. w. storage tank.

412

T2

T4 R2 R3+ R4-

R1 T3

R5

T4 R2 R3+ R4-

T3

T6

R1

415b

T2

T1 R6

R8-

416b

T2

R1

416c

T2

R1

419

T2

R2

R8

420

T2

R3 R8

T6

R1

R2

R1

R5

Combined (wood/oil) boiler, d. h. w. storage tank, mixing circuit.

421

T2

T6

T6

422b

T4 R2 R3+ R4-

T3

R8 T6

R7 R5

T4 R2 R3+ R4-

T3

R8

Combined (wood/oil) boiler, mixing circuit, d. h. w. storage tank.

422

T2

R1

Heat pump, mixing circuit, d. h. w. storage tank, solar collectors.

422c

R8 T6

T4 R2 R3+ R4-

T3 R1

T4 R2 R3+ R4-

R7

R7

T5

R8

R5 T5

T3

R1

T6

Heat pump, heating support with electricity, direct circuit, d. h. w. storage tank. T2

T6 T5

T5

Heat pump, direct circuit, d. h. w. storage tank.

R7 R5

T4 R2 R3+ R4-

T3

R1

T5

418

T2

R8

R7

T3

T5

T2

T5

Oil boiler, heat accumulator, mixing circuit, d. h. w. storage tank.

T4 R2 R3+ R4-

T3 R5

R7 R5

R8

T5

Oil boiler, heat accumulator with builtin d. h. w. storage tank, mixing circuit.

R7 R5

R7 T6

T4 R2 R3+ R4-

T6 R1

417

T2

T4 R7 R2 R3+ T5 R4T6

R5

T3

416

T2

T3

Wood boiler, oil boiler, heat accumulator, mixing circuit, d. h. w. storage tank.

T5

Wood boiler, heat accumulator, mixing circuit, d. h. w. storage tank.

R5

R8-

Wood boiler, heat accumulator with built-in d. h. w. storage tank, mixing circuit.

T4 R2 R3+ T5 R4T6

T3

R7+

T1 R6

R7

Gas boiler, heat accumulator with built-in d. h. w. storage tank, mixing circuit.

R8

R1

R5

R7+ R8-

T1 R6

T4 R2 R3+ T5 R4T6

T3 T8

R8-

Combined (wood/oil), heat accumulator with built-in d. h. w. storage tank, mixing circuit.

T3

415c

T4 R2 R3+ R4-

T6

T5

T2

R7+

414b

T3

R5

R7+ R8-

T1 R6

Heat accumulator, oil bolier, mixing circuit, d. h. w. storage tank.

T2

Combined (wood/oil) boiler, heat accumulator, mixing circuit, d. h. w. storage tank.

T4 R2 R3+ R4T6

T5

T3

T4 R2 R3+ R4-

T6

T5

R7+

T1 R6

T3

T6

R1

T4 R2 R3+ R4T6

T5

414

T2

Combined (wood/oil) boiler, mixing circuit, d. h. w. storage tank.

415

T2

Heat accumulator with built-in d. h. w. storage tank, oil boiler, mixing circuit.

R7 R5

T5

Pellet boiler, mixing circuit, d. h. w. storage tank.

R1

413

T2

R7

R2 T1

T3

Heat accumulator, gas boiler, mixing circuit, d. h. w. storage tank.

Oil boiler, heat accumulator, mixing circuit, d. h. w. storage tank. 422d

T2

R7 R8

R5 T5

Heat pump, heating support with electricity, mixing circuit, d. h. w. storage tank.

R7

T3

T5

R1 R5

T4 R2 R3+ R4-

T6

Heat pump, combined (oil/electricity) boiler, heat accumulator with built-in d. h. w. storage tank, mixing circuit.

Heat pump, mixing circuit, d. h. w. storage tank. 423

T2

T4 R2 R3+ R4-

T3

1

T1 R6 R7+ R8-

2

R5

T6

R1 T5

Oil boiler, 2x mixing circuit, d. h. w. storage tank.

45


HYDRAULIC SCHEMES The illustrated hydraulic schemes are supported in the following controllers: PROMATIC速 WDC20. 423b

T2

R5 T5

T3 R1

T1

1

T4 R2 R3+ R4-

T6 R6 R7+ R8-

423c

T2

R1

2

T4 R2 R3+ T5 R4T1

T3

Combined (oil/electricity) boiler, heat accumulator with built-in d. h. w. storage tank, 2x mixing circuit. 423f

T2

1

T6 R6 R7+ R8-

423d

T2

2

T4 R2 R3+ R4-

T5 R5 R1

Gas boiler, heat accumulator with built-in d. h. w. storage tank, 2x mixing circuit. 423g

T2

1

T6 R6 R7+ R8-

2

T3

T3

1

T6 R1 R7+ R8-

2

T3

R5 T5

Wood boiler, 2x mixing circuit, d. h. w. storage tank.

46

T4 R2 R3+ R4-

R7

R1

1

T6 R6 R7+ R8-

2

R7

Heat accumulator with built-in d. h. w. storage tank, auxiliary heating with electricity, 2x mixing circuit. 423h

T2

R5 T5

Combined (wood/oil) boiler, 2x mixing circuit, d. h. w. storage tank.

T4 R2 R3+ R4-

1

T4 R2 R3+ R4-

1

T6 R1 R7+ R8-

2

R7 R5 T5

T3

BUS

T4 R2 R3+ R4-

423e

T2

T6 R1 R7+ R8-

2

R5 T5

System expand, 2x mixing circuit, d. h. w. storage tank.

Heat accumulator, 2x mixing circuit, d. h. w. storage tank.


ORDERING CODES Controller PROMATIC® WDC10B Code: 2WDC10B00000-010 Controller PROMATIC® WDC10B incl. 2xTF/Pt, 1xAF/Pt and 1xVF/Pt Code: 2WDC10B21100-010 Controller PROMATIC® WDC10 Code: 2WDC1000000-010

Controller PROMATIC® WDC10 incl. 4xTF/Pt, 1xAF/Pt and 1xVF/Pt Code: 2WDC1041100-010

Controller PROMATIC® WDC20 Code: 2WDC2000000-010

Controller PROMATIC® WDC20 incl. 4xTF/Pt, 1xAF/Pt and 1xVF/Pt Code: 2WDC2041100-010 Surface sensor VF/Pt Code: 1VFPT-000 Immersion sensor TF/Pt Code: 1TFPT-000 Outside sensor AF/Pt Code: 1AFPT-000 Room unit RCD1 Code: 1RCD1-040 Room unit RCD1P Code: 1RCD1P-040 Room unit RCD2 Code: 1RCD2-040 Room unit RCD2P Code: 1RCD2P-040

47


Small but powerful.

48


PROMATIC速 WXD Heating controllers

49


PROMATIC速 WXD Heating controllers HIGHLIGHTS yy Control of up to 52 different hydraulic schemes. yy Control of up to two heat sources. yy Up to two mixing heating circuit control. yy Solar controller for d. h. w. warming. yy Party, Eco, Holiday and One-time domestic hot water warming functions.

yy 14 language support.

PROMATIC速 WXD are designed in size of 144 x 96 x 48 mm which makes them universal for use in new heating installations as well as replacement controllers for existing systems. They are designed to control two mixing heating circuits, domestic hot water warming with boiler and/or solar system and for control of up to two heat sources. The controller can be used for different temperature requirements of users in two separate flats or floors. In the field of renewable energy sources the WXD controller allows the connection of a heat pump and a conventional heating source in a comprehensive and economical system.

50


SIMPLICITY SOLUTION

USER FUNCTIONS Party operation mode Party operation mode is selected to extend daily or comfort mode of space heating. You can also set the time of the Party operation mode. ECO operation mode

SELTRONHOME

ECO PROMATIC® WXD controllers can be connected into the SeltronHome environment for a comprehensive remote control and operation regulation. Remote access is provided by the Clausius application for the end users and the Kelvin application for installers and servicemen.

ECO function allows heating at a lower or energy saving temperature. You can also set the time of the Eco operation mode.

One-time domestic hot water warming The function switches on the water heating instantly.

Holiday operation mode

SETUP WIZARD The controller leads you in 3- or 4- steps through the first commissioning; all other parameters are pre-set.

SYSTEM SIMULATION The simulation program is a special function which allows temperature sensor simulation, and thereby enables the user to test the system operation.

INTERACTIVE HELP Fast and easy access to short manuals, notifications, warnings, software version, etc.

By pressing the HOLIDAY operation mode the heating is set at a specific energy saving temperature until the selected date.

Anil-legionella program The controller ensures the water is bacteria-free by periodically heating water to 60 °C.

HEATING SYSTEM PROTECTION The controller ensures periodical start-up of pumps and valves during inactive period as well as protection of the solar panels, and the heater against overheating or freezing.

PC INTERFACE Through dedicated USB inverter the PROMATIC® WXD controller can be connected to a PC. The accompanying Selcontrol software allows setting and monitoring of controller operation using a PC. The solution also operates in the SeltronHome environment.

51


Heating controller PROMATIC速

WXD10B

WXD10

WXD20

7 l

17 l

52 l

max. 1 1 1

max. 2 1 1

max. 2 1 2 l

Control of 2-stage burner

l

l

l

Max. number of room units

2

2 l

2 l

Function for floor drying

l

l

l

Number of mechanical relays

7

8

9

Number of electronic relays

0

1

1

Number of temperature sensors

8 l

8 l

8 l

Function PARTY

l

l

l

Function ECO

l

l

l

HOLIDAY mode

l

l

l

Instant d.h.w. warming

l

l

l

BOOST function for room heating

l

l

l

Antilegionella protection

l

l

l

Frost protection

l

l

l

Overheating protection for boiler, collectors and storage tank

l

l

l

Anti block function for pumps and valves

l

l

l

Display of hydraulic scheme

l

l

l

Display of measured temperatures

l

l

l

Logging of settings changes

l

l

l

Simulation of system operation

l

l

l

Error and high temperature warning

l

l

l

Multilingual user interface

l

l

l

Simple adjustment of operating modes by selection of hydraulic scheme

l

l

l

Graphical adjustable time programs

l

l

l

Free programmable outputs

l

l

l

Possible installation directly on wall or on DIN rail

l

l

l

Easy installation and connection

l

l

l

Remote activation via telephone

l

l

l

Possibility of connection with PC

l

l

l

SeltronHome remote control with Smart phone or Tablet

l

l

l

Number of hydraulic schemes Heating or cooling Number of heating circuits - of which direct circuits - of which mixing circuits Switching between two heating sources

Solar pump speed control

BUS conection with other controllers

FEATURES

USER FUNCTIONS

HEATING SYSTEM PROTECTION

DATA DISPLAY

SETTINGS AND INSTALLATION

REMOTE ACCESS

52


Heating controller PROMATIC速

WXD10B

Solar collectors

REGULATED ELEMENTS

HEAT SOURCE

Solid fuel boiler

l

WXD10

WXD20

l

l

l

l l

Boiler with pellet burner Oil boiler

l

l

l

Combined boiler for liquid and solid fuel

l

Gas boiler

l

Heat pump

l

Heat accumulator

l

l

l

Additional electric heating

l

l

l

Direct heating circuit

l

l

l

Mixing heating circuit

l

l

l

Radiators

l

l

l

Floor heating

l

l

l

Heat accumulator warming

l

l

l

Domestic hot water circulation

l

l

l

Switching between direct heating circuit and domestic hot water

l

l

l l

Switching between two heat sources Control of constant stand- or return- pipe temperature 1-phase storage tank loading

l

l

l l

53


TECHNICAL DATA WXD10B

WXD10

Power supply

230 V ~, 50 Hz

Consumption

5 VA

Consumtion in standby

max. 0,5 W

Relay output

4 (1) A ~, 230 V ~

Triac output

1 (1) A ~, 230 V ~

Degree of protection

IP20 according to EN 60529

Safety class

I according to EN 60730-1

Operation type

1B acc. to EN 60730-1

Temperature sensor type

Pt1000 or KTY10

Mixing valve control

3-point PID

Controller housing

PC+ABS - thermoplastics

Dimensions

144 x 96 x 48 mm

Ambient temperature

5 째C ... +40 째C

Storage temperature

-20 째C ... +65 째C

Weight Package

54

WXD20

424 g

428 g 12 pcs

429 g


ENTRY AND NAVIGATION THROUGH THE MENU With

and

menu. With key

CONTROLLER CONNECTION

key you move along the you confirm your

selection. By pressing the key

you

return to previous sccreen.

Using a mini USB connection you can connect the controller to a PC or a mobile device.

The * key is used to program user defined shortcut.

BUS CONNECTION Outdoor sensor

Heat source

TEMPERATURE SETTING

Using BUS-connection it is possible to establish a network of Seltron controllers.

CONNECTION OF ROOM UNITS

With

and

key you set the preferred

temperature. With key your selection.

you confirm

1

2

1

2

7 GND

Up to two room units can be connected to a controller.

55


HYDRAULIC SCHEMES The illustrated hydraulic schemes are supported in the following controllers: PROMATIC速 WXD10B, WXD10, WXD20. 401

T2

T4 R2 R3+ R4-

T3

401b

T2

R6 R5

T4 R2 R3+ R4-

T3 T6

401c

T2

T4 R2 R3+ R4-

R6 R5

T3

T6

401d

T2

T4 R2 R3+ R4-

R6 R5

T6

R6 R5

T6

R1 T5

T5

Oil boiler, mixing circuit, d. h. w. storage tank. 401e

T5

Wood boiler, mixing circuit, d. h. w. storage tank.

Heat accumulator, mixing circuit, d. h. w. storage tank. 402

T2

T5

System without boiler - mixing circuit, d. h. w. storage tank. 403

T2

BUS

T4 R2 R3+ R4-

R2

R6 R5

R6

T3

T6

R5

R6 T3

T6

R1

R2 R3 R1

T5

T5

System expand - mixing circuit, d. h. w. storage tank.

T6

R4

T5

Oil boiler, direct circuit, d. h. w. storage tank.

Oil boiler, direct circuit, d. h. w. storage tank.

The illustrated hydraulic schemes are supported in the following controllers: PROMATIC速 WXD10, WXD20. 404

T2

404b

T2

T7 T4 R2 R3+ R4-

T3

R7

R5

T4 R2 R3+ R4-

T3 T5

R1

Oil boiler, mixing circuit, d. h. w. storage tank, solar collectors.

404f

T4 R7 R2 R3+ R4-

T5

T5

T3 R9

T6

Heat accumulator, mixing circuit, d. h. w. storage tank, solar collectors.

T7

R7

R5

R9

404e

T2

T4 R2 R3+ R4-

T3

T5 T6

404d

T2

T7

R7

R5

R9

T6

404c

T2

T7

Wood boiler, mixing circuit, d. h. w. storage tank, solar collectors.

405

T2

R9

T6

Heat accumulator with built-in d. h. w. storage tank, mixing circuit, solar collectors. 406

T2

BUS

T7

T7 T4 R2 R3+ R4-

T4 R7 R2 R3+ R4-

T5 R5 R1 T6

T3

R2

R7

R5

Heat accumulator with built-in d. h. w. storage tank, mixing circuit, auxiliary heating wit electricity, solar collectors. 407

T2

407b

T2 T7

T4 R2 R3+ R4-

T3

1

2

R6

T4 R2 R3+ R4-

R7 R5

T6

R1

T3

1

2

R6 R5

T5

R7* T5

R1 T6

R9

* WXD20, KXD20

Oil boiler, direct circuit, mixing circuit, d. h. w. storage tank, solar collectors.

56

Oil boiler, mixing and direct circuit, d. h. w. storage tank, solar collectors.

R2 R3

T3

T5 T6

System expand - mixing circuit, d. h. w. storage tank, solar collectors.

R7

R7

R1

R9

T6

R5

T3

T5

R9

T7

T7

R9

Oil boiler, direct circuit, d. h. w. storage tank, solar collectors.

R1

R4

T5 T6

R9

Oil boiler, direct circuit, d. h. w. storage tank, solar collectors.


HYDRAULIC SCHEMES The illustrated hydraulic schemes are supported in the following controllers: PROMATIC速 WXD20. 408

T2

T4 R2 R3+ R4-

T6 R8

R1

408b

T2

T4 R2 R3+ R4-

R1 R7

T6

R5

T3

R7

T4 R2 R3+ T3 R4-

T6

R5 T5

T5

T3

409

T2

R8

409b

T2

T4 R2 R3+ R4-

R1

R7

T6

R5

T3

T5

R1

R7 R5 T5

R8

R8

Wood boiler, oil boiler, mixing circuit, d. h. w. storage tank. 410

T2

T4 R2 R3+ R4-

T6 T3 R1

R8

T6 T3

T5

412

T2

T4 R2 R3+ R4-

415b

R7+

T1 R6

R8-

416b

T2

Wood boiler, heat accumulator with built-in d. h. w. storage tank, mixing circuit. 416c

T2

T4 R2 R3+ T5 R4T6

R1

Gas boiler, heat accumulator with built-in d. h. w. storage tank, mixing circuit. 419

T2

R8

R2 T3

R4

420

T2

T6 R3

T5

T4 R2 R3+ R4-

R7 R5 T3 T6

R1

Heat pump, mixing circuit, d. h. w. storage tank, solar collectors.

T4 R2 R3+ R4-

T3 R1

T4 R2 R3+ R4-

T4 R2 R3+ R4R1

T3

T6

R8

T5

Combined (wood/oil) boiler, mixing circuit, d. h. w. storage tank.

422

T2

T4 R2 R3+ R4-

R7

R7

T5

R8

R5 T5

R1

T3

R1

T6

422c

T3

R7 R5

T5

T2

T6

421

T2

T6

Heat pump, heating support with electricity, direct circuit, d. h. w. storage tank.

R8

Combined (wood/oil) boiler, d. h. w. storage tank, mixing circuit.

T6 R3

422b

T2

R8

T3 R4

R2

T5

Heat pump, direct circuit, d. h. w. storage tank.

418

T2

R8

R7

R1 R8

R1

T5

Oil boiler, heat accumulator, mixing circuit, d. h. w. storage tank.

T4 R2 R3+ R4-

T3 R5

R7 R5

R8

T5

Oil boiler, heat accumulator with builtin d. h. w. storage tank, mixing circuit.

R7 R8

R7 T6

T4 R2 R3+ R4-

T6 R1

417

T2

T4 R7 R2 R3+ T5 R4T6

R5

T3

416

T2

T3

Wood boiler, oil boiler, heat accumulator, mixing circuit, d. h. w. storage tank.

T5

Wood boiler, heat accumulator, mixing circuit, d. h. w. storage tank.

R5

R8-

R7

T3

R7+

T1 R6

R8-

Combined (wood/oil), heat accumulator with built-in d. h. w. storage tank, mixing circuit.

R1

R1

R5

R7+ R8-

T1 R6

T4 R2 R3+ T5 R4T6

T3 T8

T4 R2 R3+ R4-

T6

T3

415c

R7+

T1 R6

414b

T5

T2

T5

Heat accumulator, oil bolier, mixing circuit, d. h. w. storage tank.

R5

R7+ R8-

T1 R6

R7 R5

R1

T2

Combined (wood/oil) boiler, heat accumulator, mixing circuit, d. h. w. storage tank.

T4 R2 R3+ R4T6

T5

T3

T4 R2 R3+ R4-

T6 R1

T2

T4 R2 R3+ R4T6

T5

414

T5

Combined (wood/oil) boiler, mixing circuit, d. h. w. storage tank.

415

R8

T2

R1

T4 R2 R3+ T3 R4-

T6

Heat accumulator with built-in d. h. w. storage tank, oil boiler, mixing circuit.

T3

T6

411

T2

R1

T1

R8

R7 R5

T5

T2

T3

T6

T5

Heat accumulator, gas boiler, mixing circuit, d. h. w. storage tank.

T4 R2 R3+ R4-

R5

T5

413

T6

Pellet boiler, mixing circuit, d. h. w. storage tank.

R1

R7

T2

T4 R2 R3+ R4-

410 c

T2

R7

Heat accumulator, gas boiler, mixing circuit, d. h. w. storage tank.

T3

Heat accumulator, oil boiler, mixing circuit, d. h. w. storage tank.

R5 T1

R8

R7 R5

R2 T1

T3

T4 R2 R3+ R4-

R1 R7

Heat accumulator, oil boiler, mixing circuit, d. h. w. storage tank.

R1

410b

T2

R5

T1

T3

Wood boiler, gas boiler, mixing circuit, d. h. w. storage tank.

Oil boiler, heat accumulator, mixing circuit, d. h. w. storage tank. 422d

T2

R7 T5

Heat pump, heating support with electricity, mixing circuit, d. h. w. storage tank.

R7

T3 R8

R5

T5

R1 R5

T4 R2 R3+ R4-

T6

Heat pump, combined (oil/electricity) boiler, heat accumulator with built-in d. h. w. storage tank, mixing circuit.

Heat pump, mixing circuit, d. h. w. storage tank. 423

T2

T4 R2 R3+ R4-

T3

1

T6 R6 R7+ R8-

2

R5

R1

T5

Oil boiler, 2x mixing circuit, d. h. w. storage tank.

57


HYDRAULIC SCHEMES The illustrated hydraulic schemes are supported in the following controllers: PROMATIC速 WXD20. 423b

T2

R5 T5

T3 R1

T1

1

T4 R2 R3+ R4-

T6 R6 R7+ R8-

R1

2

423f

1

T4 R2 R3+ T5 R4T1

T3

Combined (oil/electricity) boiler, heat accumulator with built-in d. h. w. storage tank, 2x mixing circuit. T2

423c

T2

T6 R6 R7+ R8-

423d

T2

2

T4 R2 R3+ R4-

T5 R5 R1

Gas boiler, heat accumulator with built-in d. h. w. storage tank, 2x mixing circuit.

1

T6 R6 R7+ R8-

2

T3

Heat accumulator with built-in d. h. w. storage tank, auxiliary heating with electricity, 2x mixing circuit. 423h BUS

T3

T4 R2 R3+ R4-

1

T6 R6 R7+ R8-

2

T5

Wood boiler, 2x mixing circuit, d. h. w. storage tank.

58

T4 R2 R3+ R4-

T3

R5

R1

1

T6 R6 R7+ R8-

2

T4 R2 R3+ R4-

R5 T5

Combined (wood/oil) boiler, 2x mixing circuit, d. h. w. storage tank.

T4 R2 R3+ R4-

1

T6 R6 R7+ R8-

2

R5

T3

423g

T2

423e

T2

1

T6 R6 R7+ R8-

2

R5 T5

System expand, 2x mixing circuit, d. h. w. storage tank.

T5

Heat accumulator, 2x mixing circuit, d. h. w. storage tank.


ORDERING CODES Heating controller PROMATIC® WXD10B incl. 2xTF/Pt, 1xVF/Pt, 1xAF/Pt Code: 2WXD10B21100-510 Heating controller PROMATIC® WXD10 incl. 4xTF/Pt, 1xVF/Pt, 1xAF/Pt Code: 2WXD1041100-510

Heating controller PROMATIC® WXD20 incl. 4xTF/Pt, 1xVF/Pt, 1xAF/Pt Code: 2WXD2041100-510 Actuator PROMIX® AVC05, 5 Nm, 2 min., 230V Code: 1AVC0532M210-030 Actuator PROMIX® AVC05R, 5 Nm, 2 min., 230V Code: 1AVC0522M210-030 Surface sensor VF/Pt Code: 1VFPT-000 Immersion sensor TF/Pt Code: 1TFPT-000 Outside sensor AF/Pt Code: 1AFPT-000 Immersion sensor CF Code: 1CFPT-000 Room unit RCD1 Code: 1RCD1-040 Room unit RCD1P Code: 1RCD1P-040 Room unit RCD2 Code: 1RCD2-040 Room unit RCD2P Code: 1RCD2P-040

59


All in one.

60


PROMATIC速 KXD Boiler and heating controllers

61


PROMATIC速 KXD Boiler and heating controllers HIGHLIGHTS yy Control of up to 52 different hydraulic schemes. yy Control up to two heat sources. yy Control of up to two mixing circuit. yy Solar controller for d. h. w. warming. yy Party, Eco, Holiday and One-time. yy domestic hot water warming functions. yy 14 language support.

PROMATIC速 KXD controllers are designed to control boiler, temperature of the living space, domestic hot water, another heat source and solar systems. Simple handling of the controller is based on user friendly interface with graphical icons. With Seltron simplicity solutions built-in the controller offers a wealth of comfort and advantages to the user. Selection between 52 different hydraulic schemes, including schemes with two mixing circuits or two heat sources and solar system. All controller settings are permanently stored, user settings can be saved to a user file and later activated. Each change of controller setting, exceeded maximum temperature or system malfunction is written to a log. All measured temperatures are periodically stored, data can be viewed on display at any time. Can be mounted onto the panel or on the boiler.

62


SIMPLICITY SOLUTION

USER FUNCTIONS Party operation mode Party operation mode is selected to extend daily or comfort mode of space heating. You can also set the time of the Party operation mode. ECO operation mode

SELTRONHOME

ECO PROMATIC® KXD controllers can be connected into the SeltronHome environment for a comprehensive remote control and operation regulation. Remote access is provided by the Clausius application for the end users and the Kelvin application for installers and servicemen.

ECO function allows heating at a lower or energy saving temperature. You can also set the time of the Eco operation mode.

One-time domestic hot water warming The function switches on the water heating instantly.

Holiday mode of the solar system operation

SETUP WIZARD The controller leads you in 3- or 4- steps through the first commissioning; all other parameters are pre-set.

By pressing the HOLIDAY operation mode the heating is set at a specific energy saving temperature until the selected date.

Anti-legionella program The controller ensures the medium is bacteriafree by periodically heating water to 60 °C.

SYSTEM SIMULATION The simulation program is a special function which allows temperature sensor simulation, and thereby enables the user to test the system operation.

HEATING SYSTEM PROTECTION The controller ensures periodical start-up of pumps and valves during inactive period as well as protection of the solar panels, and the heater against overheating or freezing.

INTERACTIVE HELP Fast and easy access to short manuals, notifications, warnings, software version, etc.

PC INTERFACE Through dedicated USB inverter the PROMATIC® KXD controller can be connected to a PC. The accompanying Selcontrol software allows setting and monitoring of controller operation using a PC. The solution also operates in the SeltronHome environment.

63


Heating controller PROMATIC速

KXD10B

KXD10

KXD20

7 l

17 l

52 l

max. 1 1 1

max. 2 1 1

max. 2 1 2 l

Control of 2-stage burner

l

l

l

Max. number of room units

2

2 l

2 l

Function for floor drying

l

l

l

Number of mechanical relays

7

8

9

Number of electronic relays

0

1

1

Number of temperature sensors

8 l

8 l

8 l

Function PARTY

l

l

l

Function ECO

l

l

l

HOLIDAY mode

l

l

l

Instant d.h.w. warming

l

l

l

BOOST function for room heating

l

l

l

Antilegionella protection

l

l

l

Frost protection

l

l

l

Overheating protection for boiler, collectors and storage tank

l

l

l

Anti block function for pumps and valves

l

l

l

Display of hydraulic scheme

l

l

l

Display of measured temperatures

l

l

l

Logging of settings changes

l

l

l

Simulation of system operation

l

l

l

Error and high temperature warning

l

l

l

Multilingual user interface

l

l

l

Simple adjustment of operating modes by selection of hydraulic scheme

l

l

l

Graphical adjustable time programs

l

l

l

Free programmable outputs

l

l

l

Possible installation directly on wall or on DIN rail

l

l

l

Easy installation and connection

l

l

l

Remote activation via telephone

l

l

l

Possibility of connection with PC

l

l

l

SeltronHome remote control with Smart phone or Tablet

l

l

l

Number of hydraulic schemes Heating or cooling Number of heating circuits - of which direct circuits - of which mixing circuits Switching between two heating sources

Solar pump speed control

BUS conection with other controllers

FEATURES

USER FUNCTIONS

HEATING SYSTEM PROTECTION

DATA DISPLAY

SETTINGS AND INSTALLATION

REMOTE ACCESS

64


Heating controller PROMATIC速

KXD10B

Solar collectors

REGULATED ELEMENTS

HEAT SOURCE

Solid fuel boiler

l

KXD10

KXD20

l

l

l

l l

Boiler with pellet burner Oil boiler

l

l

l

Combined boiler for liquid and solid fuel

l

Gas boiler

l

Heat pump

l

Heat accumulator

l

l

l

Additional electric heating

l

l

l

Direct heating circuit

l

l

l

Mixing heating circuit

l

l

l

Radiators

l

l

l

Floor heating

l

l

l

Heat accumulator warming

l

l

l

Domestic hot water circulation

l

l

l

Switching between direct heating circuit and domestic hot water

l

l

l l

Switching between two heat sources Control of constant stand- or return- pipe temperature 1-phase storage tank loading

l

l

l l

65


TECHNICAL DATA KXD10B

KXD10

Power supply

230 V ~, 50 Hz

Consumption

5 VA

Consumption in standby

max. 0,5 W

Relay output

4(1) A ~, 230 V ~

Triac output

1(1) A ~, 230 V~

Degree of protection

IP20 according to EN 60529

Safety class

I according to EN 60730-1

Operation type

1B acc. to EN 60730-1

Temperature sensor type

Pt1000 or KTY10

Mixing valve control

3-point PID

Controller housing

PC+ABS - thermoplastics

Dimensions

211 x 96 x 53 (58) mm

Ambient temperature

5 째C ... +40 째C

Storage temperature

-20 째C ... +65 째C

Weight Package unit

66

KXD20

779 g

783 g 6 pcs

784 g


STB THERMAL SAFETY FUSE

CONTROLLER INSTALLATION IN OR ON TO THE BOILER HOUSING

Thermal safety fuse serves as thermal protection of the heat source by cutting of power supply to the burner if the temperature exceeds 110 °C. Red alert inscription on STB signals that thermal safety fuse has been activated.

Controller can be installed in a dry room, avoiding immediate vicinity of sources of strong electromagnetic field. It can be fixed inside or onto the boiler siding.

Example of installation on to the boiler.

CHIMNEY SWEEP KEY KXD controllers feature “Chimney sweep function” which helps the chimney sweeper and installer by fine tuning the burner and boiler emission test. “STB test” function helps the installer to check operation of safety thermal fuse STB.

45°- 60 °-75 °-

90 °

148 mm

120 mm

DIMENSIONS

129 mm 53 mm 58 mm 63 mm

67


HYDRAULIC SCHEMES The illustrated hydraulic schemes are supported in the following controllers: PROMATIC速 KXD10B, KXD10, KXD20. 401

T2

T4 R2 R3+ R4-

T3

401b

T2

R6 R5

T4 R2 R3+ R4-

T3 T6

401c

T2

T4 R2 R3+ R4-

R6 R5

T3

T6

401d

T2

T4 R2 R3+ R4-

R6 R5

T6

R6 R5

T6

R1 T5

T5

Oil boiler, mixing circuit, d. h. w. storage tank. 401e

T5

Wood boiler, mixing circuit, d. h. w. storage tank.

Heat accumulator, mixing circuit, d. h. w. storage tank. 402

T2

T5

System without boiler - mixing circuit, d. h. w. storage tank. 403

T2

BUS

T4 R2 R3+ R4-

R2

R6 R5

R6

T3

T6

R5

R6 T3

T6

R1

R2 R3 R1

T5

T5

System expand - mixing circuit, d. h. w. storage tank.

T6

R4

T5

Oil boiler, direct circuit, d. h. w. storage tank.

Oil boiler, direct circuit, d. h. w. storage tank.

The illustrated hydraulic schemes are supported in the following controllers: PROMATIC速 KXD10, KXD20. 404

T2

404b

T2

T7 T4 R2 R3+ R4-

T3

R7

R5

T4 R2 R3+ R4-

T3 T5

R1

Oil boiler, mixing circuit, d. h. w. storage tank, solar collectors.

404f

T4 R7 R2 R3+ R4-

T5

T5

T3 R9

T6

Heat accumulator, mixing circuit, d. h. w. storage tank, solar collectors.

T7

R7

R5

R9

404e

T2

T4 R2 R3+ R4-

T3

T5 T6

404d

T2

T7

R7

R5

R9

T6

404c

T2

T7

Wood boiler, mixing circuit, d. h. w. storage tank, solar collectors.

405

T2

R9

T6

Heat accumulator with built-in d. h. w. storage tank, mixing circuit, solar collectors. 406

T2

BUS

T7

T7 T4 R2 R3+ R4-

T4 R7 R2 R3+ R4-

T5 R5 R1 T6

T3

R2

R7

R5

Heat accumulator with built-in d. h. w. storage tank, mixing circuit, auxiliary heating wit electricity, solar collectors. 407

T2

407b

T2 T7

T4 R2 R3+ R4-

T3

1

2

R6

T4 R2 R3+ R4-

R7 R5

T6

R1

T3

1

2

R6 R5

T5

R7* T5

R1 T6

R9

* WXD20, KXD20

Oil boiler, direct circuit, mixing circuit, d. h. w. storage tank, solar collectors.

68

Oil boiler, mixing and direct circuit, d. h. w. storage tank, solar collectors.

R2 R3

T3

T5 T6

System expand - mixing circuit, d. h. w. storage tank, solar collectors.

R7

R7

R1

R9

T6

R5

T3

T5

R9

T7

T7

R9

Oil boiler, direct circuit, d. h. w. storage tank, solar collectors.

R1

R4

T5 T6

R9

Oil boiler, direct circuit, d. h. w. storage tank, solar collectors.


HYDRAULIC SCHEMES The illustrated hydraulic schemes are supported in the following controllers: PROMATIC速 KXD20. 408

T2

T4 R2 R3+ R4-

T6 R8

R1

408b

T2

T4 R2 R3+ R4-

R1 R7

T6

R5

T3

R7

T4 R2 R3+ T3 R4-

T6

R5 T5

T5

T3

409

T2

R8

409b

T2

T4 R2 R3+ R4-

R1

R7

T6

R5

T3

T5

R1

R7 R5 T5

R8

R8

Wood boiler, oil boiler, mixing circuit, d. h. w. storage tank. 410

T2

T4 R2 R3+ R4-

T6 T3 R1

R8

T6 T3

T5

412

T2

T4 R2 R3+ R4-

415b

R7+

T1 R6

R8-

416b

T2

Wood boiler, heat accumulator with built-in d. h. w. storage tank, mixing circuit. 416c

T2

T4 R2 R3+ T5 R4T6

R1

Gas boiler, heat accumulator with built-in d. h. w. storage tank, mixing circuit. 419

T2

R8

R2 T3

R4

420

T2

T6 R3

T5

T4 R2 R3+ R4-

R7 R5 T3 T6

R1

Heat pump, mixing circuit, d. h. w. storage tank, solar collectors.

T4 R2 R3+ R4-

T3 R1

T4 R2 R3+ R4-

T4 R2 R3+ R4R1

T3

T6

R8

T5

Combined (wood/oil) boiler, mixing circuit, d. h. w. storage tank.

422

T2

T4 R2 R3+ R4-

R7

R7

T5

R8

R5 T5

R1

T3

R1

T6

422c

T3

R7 R5

T5

T2

T6

421

T2

T6

Heat pump, heating support with electricity, direct circuit, d. h. w. storage tank.

R8

Combined (wood/oil) boiler, d. h. w. storage tank, mixing circuit.

T6 R3

422b

T2

R8

T3 R4

R2

T5

Heat pump, direct circuit, d. h. w. storage tank.

418

T2

R8

R7

R1 R8

R1

T5

Oil boiler, heat accumulator, mixing circuit, d. h. w. storage tank.

T4 R2 R3+ R4-

T3 R5

R7 R5

R8

T5

Oil boiler, heat accumulator with builtin d. h. w. storage tank, mixing circuit.

R7 R8

R7 T6

T4 R2 R3+ R4-

T6 R1

417

T2

T4 R7 R2 R3+ T5 R4T6

R5

T3

416

T2

T3

Wood boiler, oil boiler, heat accumulator, mixing circuit, d. h. w. storage tank.

T5

Wood boiler, heat accumulator, mixing circuit, d. h. w. storage tank.

R5

R8-

R7

T3

R7+

T1 R6

R8-

Combined (wood/oil), heat accumulator with built-in d. h. w. storage tank, mixing circuit.

R1

R1

R5

R7+ R8-

T1 R6

T4 R2 R3+ T5 R4T6

T3 T8

T4 R2 R3+ R4-

T6

T3

415c

R7+

T1 R6

414b

T5

T2

T5

Heat accumulator, oil bolier, mixing circuit, d. h. w. storage tank.

R5

R7+ R8-

T1 R6

R7 R5

R1

T2

Combined (wood/oil) boiler, heat accumulator, mixing circuit, d. h. w. storage tank.

T4 R2 R3+ R4T6

T5

T3

T4 R2 R3+ R4-

T6 R1

T2

T4 R2 R3+ R4T6

T5

414

T5

Combined (wood/oil) boiler, mixing circuit, d. h. w. storage tank.

415

R8

T2

R1

T4 R2 R3+ T3 R4-

T6

Heat accumulator with built-in d. h. w. storage tank, oil boiler, mixing circuit.

T3

T6

411

T2

R1

T1

R8

R7 R5

T5

T2

T3

T6

T5

Heat accumulator, gas boiler, mixing circuit, d. h. w. storage tank.

T4 R2 R3+ R4-

R5

T5

413

T6

Pellet boiler, mixing circuit, d. h. w. storage tank.

R1

R7

T2

T4 R2 R3+ R4-

410 c

T2

R7

Heat accumulator, gas boiler, mixing circuit, d. h. w. storage tank.

T3

Heat accumulator, oil boiler, mixing circuit, d. h. w. storage tank.

R5 T1

R8

R7 R5

R2 T1

T3

T4 R2 R3+ R4-

R1 R7

Heat accumulator, oil boiler, mixing circuit, d. h. w. storage tank.

R1

410b

T2

R5

T1

T3

Wood boiler, gas boiler, mixing circuit, d. h. w. storage tank.

Oil boiler, heat accumulator, mixing circuit, d. h. w. storage tank. 422d

T2

R7 T5

Heat pump, heating support with electricity, mixing circuit, d. h. w. storage tank.

R7

T3 R8

R5

T5

R1 R5

T4 R2 R3+ R4-

T6

Heat pump, combined (oil/electricity) boiler, heat accumulator with built-in d. h. w. storage tank, mixing circuit.

Heat pump, mixing circuit, d. h. w. storage tank. 423

T2

T4 R2 R3+ R4-

T3

1

T6 R6 R7+ R8-

2

R5

R1

T5

Oil boiler, 2x mixing circuit, d. h. w. storage tank.

69


HYDRAULIC SCHEMES The illustrated hydraulic schemes are supported in the following controllers: PROMATIC速 KXD20. 423b

T2

R5 T5

T3 R1

T1

1

T4 R2 R3+ R4-

T6 R6 R7+ R8-

R1

2

423f

1

T4 R2 R3+ T5 R4T1

T3

Combined (oil/electricity) boiler, heat accumulator with built-in d. h. w. storage tank, 2x mixing circuit. T2

423c

T2

T6 R6 R7+ R8-

423d

T2

2

T4 R2 R3+ R4-

T5 R5 R1

Gas boiler, heat accumulator with built-in d. h. w. storage tank, 2x mixing circuit.

1

T6 R6 R7+ R8-

2

T3

Heat accumulator with built-in d. h. w. storage tank, auxiliary heating with electricity, 2x mixing circuit. 423h BUS

T3

T4 R2 R3+ R4-

1

T6 R6 R7+ R8-

2

T5

Wood boiler, 2x mixing circuit, d. h. w. storage tank.

70

T4 R2 R3+ R4-

T3

R5

R1

1

T6 R6 R7+ R8-

2

T4 R2 R3+ R4-

R5 T5

Combined (wood/oil) boiler, 2x mixing circuit, d. h. w. storage tank.

T4 R2 R3+ R4-

1

T6 R6 R7+ R8-

2

R5

T3

423g

T2

423e

T2

1

T6 R6 R7+ R8-

2

R5 T5

System expand, 2x mixing circuit, d. h. w. storage tank.

T5

Heat accumulator, 2x mixing circuit, d. h. w. storage tank.


ORDERING CODES Boiler controller PROMATIC® KXD10B incl. 2xTF/Pt, 1xVF/Pt, 1xAF/Pt Code: 2KXD10B2211-510 Boiler controller PROMATIC® KXD10 incl. 4xTF/Pt, 1xVF/Pt, 1xAF/Pt Code: 2KXD102411-510

Boiler controller PROMATIC® KXD20 incl. 4xTF/Pt, 1xVF/Pt, 1xAF/Pt Code: 2KXD202411-510 Actuator PROMIX® AVC05, 5 Nm, 2 min., 230V Code: 1AVC0532M210-030 Actuator PROMIX® AVC05R, 5 Nm, 2 min., 230V Code: 1AVC0522M210-030 Surface sensor VF/Pt Code: 1VFPT-000 Immersion sensor TF/Pt Code: 1TFPT-000 Outside sensor AF/Pt Code: 1AFPT-000 Immersion sensor CF Code: 1CFPT-000 Room sensor PS10 Code: 2PS10PT-510 Room unit RCD1 Code: 1RCD1-040 Room unit RCD1P Code: 1RCD1P-040 Room unit RCD2 Code: 1RCD2-040 Room unit RCD2P Code: 1RCD2P-040

71


Control constant temperature.

72


PROMATIC速 ACC PROMATIC速 SCC Constant temperature controllers

73


PROMATIC速 ACC and SCC Constant temperature controllers HIGHLIGHTS yy Fits on more than 20 different valves. yy Simple installation and setting. yy Adjustable return pipe temperature. yy LEDs for show rotation direction. * yy Built-in actuator. * yy Possibility to measure boiler produced Energy. ** * Only by controller ACC ** Only by controller SCC

PROMATIC速 ACC compact controller is designed to control a constant stand and return pipe temperature. It is built into the housing of an actuator. It is used for controlling the return temperature of solid fuel boilers, or filling of the storage tank, to control the supply temperature for swimming pools and other heating or cooling systems. ACC controller is simple to install and use. The settings are done by means of capacitive keypad that is resistant to mechanical impacts, moisture and dust. PROMATIC速 SCC is a powerful controller of constant temperature. It is intended for constant boiler return-pipe temperature control and for 2-phased storage tank loading. The function of 2-phase storage tank loading enables quick energy gain at boiler start-up and consequentially a quick start-up of the heating system. SCC controller is applicable for all kind of solid fuel boiler systems as well as for pellet boiler systems. It can manage a layered storage tank loading. SCC controller is simple to install and use. The settings are made through a setup wizard and a graphic interface.

74


SIMPLICITY SOLUTION

USER FUNCTIONS Setting of rotation direction User can easily change the opening and closing direction of the valve in the controller menu.

SELTRONHOME Boiler output power measurement PROMATIC速 ACC and SCC controllers can be connected into the SeltronHome environment for a comprehensive remote control and operation regulation. Remote access is provided by the Clausius application for the end users and the Kelvin application for installers and servicemen.

SCC controllers allow for measurement of boiler output power.

Gained Energy measurement Controller graphically displays an overview of the temperatures for the current day, current week and warnings when a temperature is exceeded or an error occurs.

SETUP WIZARD Graphic temperature display The controller leads you in 3- or 4- steps through the first commissioning; all other parameters are pre-set.

SYSTEM SIMULATION The simulation program is a special function which allows temperature sensor simulation, and thereby enables the user to test the system operation.

INTERACTIVE HELP Fast and easy access to short manuals, notifications, warnings, software version, etc.

Controller provides graphic display of temperatures for the current day or for the past week.

HEATING SYSTEM PROTECTION The controller ensures periodical start-up of pumps and valves during inactive period as well as protection against overheating or freezing.

PC INTERFACE Through dedicated USB inverter the PROMATIC速 ACC and SCC controller can be connected to a PC. The accompanying Selcontrol software allows setting and monitoring of controller operation using a PC. The solution also operates in the SeltronHome environment.

75


Constant temperature controller PROMATIC速

ACC10

ACC20

SCC30

SCC40

Number of hydraulic schemes

4

4

2

4

Number of storage tanks

1

1

1

2

l

l

Heat metering with flow sensor - impulse type (l/min) Number of mechanical relays

0

1

3

5

Number of electronic relays

2

2

1

1

Number of temperature sensors

1

2

7 l

7 l

l

l l

l

l

l

l

l

l

l

l

l

Display of hydraulic scheme

l

l

Graphic overview of temperatures and gained energy

l

l

Logging of settings changes

l

l

Simulation of system operation

l

l

l

l

Multilingual user interface

l

l

Simple adjustment of operating modes by selection of hydraulic scheme

l

l

Graphical adjustable time programs

l

l

Free programmable output

l

l

l

l

l

l

l

l

Pump speed control (RPM) Signalisation of the valve rotation direction

l

Animation of the activated circulation pump USER FUNCTIONS Heat metering (kWh)

FEATURES

HEATING SYSTEM PROTECTION Overheating protection for boiler, collectors and storage tank

l

Anti block function for pumps and valves DATA DISPLAY

Error and high temperature warning

l

l

SETTINGS AND INSTALLATION

Installation sets for many mixing valves

l

l

Adjustment of rotation direction of the actuator

l

l

Possible installation directly on wall or on DIN rail Easy installation and connection

l

l

REMOTE ACCESS Possibility of connection with PC

76


Constant temperature controller PROMATIC速

ACC10

ACC20

SCC30

SCC40

Solid fuel boiler

l

l

Boiler with pellet burner

l

l

l

l

HEAT SOURCE

Solar collectors

Oil boiler Combined boiler for liquid and solid fuel Gas boiler Heat pump l

l

l

l

Control of constant stand- or returnpipe temperature

l

l

l

l

Heat accumulator warming

l

l

l

l

1-phase storage tank loading

l

l

l

l

Heat accumulator

REGULATED ELEMENTS

Additional electric heating

2-phase storage tank loading

l

77


TECHNICAL DATA ACC10

ACC20

Power supply Consumption in standby

< 2 VA

< 4 VA

max. 0,25 W

max. 0,5 W

Relay output

4 (2) A / 230 V~

Triac output

0,1 A / 230 V ~

Torque

1 (1) A / 230 V~

6 Nm IP42 acc. to EN 60529

Safety class

IP20 acc. to EN60529 I acc. to EN60730-1

Operation type

1B acc. to EN 60730-1

Temperature sensor type

Pt1000

Pt1000 or KTY10

Mixing valve control Controller housing Dimensions (w × l × h)

3-point PID PC - thermoplastics

ASA - thermoplastics

84 × 101 × 88 mm

113 x163 x 48 mm

Ambient temperature

0 ÷ 40 °C

Storage temperature

-20 ÷ 65 °C

Weight Package unit

78

SCC40

230 V ~, 50 Hz

Consumption

Degree of protection

SCC30

668 g

848 g

406 g 12 pcs

413 g


INSTALLATION OF PROMATIC速 ACC ON THE MIXING VALVE The compact design of the controller allows quick and easy installation and reliable operation.

T1

230 VAC, 50 Hz

COMPATIBLE WITH MIXING VALVES ACC controller can be mounted on a wide range of mixing valves from different manufacturers. For this purpose various installation sets are available.

APPEARANCE a - Keypad b - LED display for indication of actual temperature and easy controller setup c - Indication of left turning direction d - Indication of pump operation (ACC20 only) e - Indication of right turning direction

b

a

c d e

79


HYDRAULIC SCHEMES The illustrated hydraulic schemes are supported in the following controllers: PROMATIC速 ACC10, ACC20. 1

2

3

4

M M

M

p M

Solid fuel boiler, heat accumulator, constant return-pipe temperature control.

Heat exchanger, constant stand-pipe temperature control.

Boiler, mixing heating circuit, constant stand-pipe temperature control.

Heat exchanger, constant stand-pipe temperature control.

The illustrated hydraulic schemes are supported in the following controllers: PROMATIC速 ACC20. 1

2

4

3

M M

M

p M

Solid fuel boiler, heat accumulator, constant return-pipe temperature control.

Heat exchanger, constant stand-pipe temperature control.

Boiler, mixing heating circuit, constant stand-pipe temperature control.

Heat exchanger, constant stand-pipe temperature control.

The illustrated hydraulic schemes are supported in the following controllers: PROMATIC速 SCC30, SCC40. 291

291b

T4

T1 T2 R2

R3+

T4

T1 R1

T3

T2 R2

R3+

T3

R4-

R4-

Solid fuel boiler, heat accumulator, constant return-pipe temperature control.

Pellet boiler, heat accumulator, constant return-pipe temperature control.

The illustrated hydraulic schemes are supported in the following controllers: PROMATIC速 SCC40. 292

T4

T1 T2 R2

R5+

R4-

R6-

T3

T6

Solid fuel boiler, heat accumulator, constant return-pipe temperature control.

80

T4

T1

T5

R3+

292b

R1

R3+

R5+

R4-

R6-

T3

T6

Pellet boiler, heat accumulator, constant return-pipe temperature control.

T5 T6

T4

T1

T5

T2 R2

293

T2 R2 R3+

R5+

R4-

R6-

T3

Solid fuel boiler, heat accumulator, constant return-pipe temperature control, staged tank loading.

293b

T1 R1

T4 T2 R2 R3+

R5+

R4-

R6-

T5 T3

T6

Pellet boiler, heat accumulator, constant return-pipe temperature control, staged tank loading.


MIXING VALVE INSTALLATION SETS

ORDERING CODES Constant temperature controller PROMATIC® ACC10 incl. 1xTF/Pt Code: 1ACC101-NN0

Sets for controllers PROMATIC® ACC CODE

MANUFACTURER

1ASCAVMSA000+NN0

Esbe, Seltron, Somatherm, Acaso, IVAR, WIP, PAW, BRV, IMIT, Hora, Barberi, Olymp, Hoval

1ASCAVMSB000+NN0

for 10Nm+ Esbe, Seltron, Somatherm, Acaso, IVAR, WIP, PAW, BRV, IMIT, Hora, Barberi, Olymp, Hoval

1ASCAVMSC000+NN0

Centra ZR/DR

1ASCAVMSD000+NN0 Centra DRU 1ASCAVMSE000+NN0

Siemens VBI, VBF

1ASCAVMSF000+NN0

Wita, Meibes

1ASCAVMSG000+NN0 Esbe VRG 1ASCAVMSH000+NN0 Firšt

Constant temperature controller PROMATIC® ACC20 incl. 2xTF/Pt Code: 1ACC2011-NN0 Constant temperature controller PROMATIC® SCC30 incl. 3xTF/Pt Code: 2SCC3030-010 Constant temperature controller PROMATIC® SCC40 incl. 3xTF/Pt Code: 2SCC4030-010 Actuator PROMIX® AVC05 Code: 1AVC0532M210-030 Actuator PROMIX® AVC05R, 5 Nm, 2 min., 230 V Code: 1AVC0522M210-030 Surface sensor VF/Pt

1ASCAVMSI000-NN0

Honeywell V544, …, V543

1ASCAVMSJ000-NN0

Paw K32, K33, K34

Immersion sensor TF/Pt

1ASCAVMSK000+NN0

Danfoss HRB, HFE, HRE

Code: 1TFPT-000

Code: 1VFPT-000

Flowmeter SVC25 Code: 1SVC25+NN0

81


Control the valve.

82


PROMIX速 AVC PROMIX速 AVE Actuators

83


PROMIX® AVC PROMIX® AVE Actuators HIGHLIGHTS yy Can be mounted on a wide range of mixing valves from different manufacturers.

yy Simple and easy installation. yy Operation indication with LED’s.

PROMIX® Seltron actuators are intended for control of the position of rotational mixing valves and ball valves. Turning direction of valve is indicated by LED light. The advantages of PROMIX® actuators are simple and quick installation in 4 possible directions, robust performance and silent operation. Special construction prevents damage in case of valve blocking. PROMIX® actuators have an optional built-in auxiliary micro switch which can be used to turn off the circulation pump when mixing valve is closed. PROMIX® actuators are maintenance free. PROMIX® AVE Seltron actuators are intended for installation into compact pump groups of smaller size (up to DN20). Their main feature is compact size and quick installation. Their design is suitable for left or right stand pipe orientation.

84


MIXING VALVE POSITION IS NO LONGER AN OBSTACLE By actuator mounting we are often confronting with diverse positions of the mixing valves. For our actuators this is not an obstacle, because they can be mounted in any position.

FAST AND SIMPLE INSTALLATION With the help of mounting sets, the actuator can be easily installed on a mixing valve. A manual turn of the valve can be done with the help of a button or a handle. Where manual turn of the valve is not allowed, there is a position indicator available.

c

a

c

i

f

b

h d k

e k g

a - mixing valve b - installation set c - anti-rotation screw d - actuator PROMIX速 AVC e - clutch f - indication scale g - handle h - knob i - indicator j - knob cover k - fixing screw

j k

85


Actuator PROMIX®

AVC

AVE

Output torque

5 Nm, 10 Nm or 15 Nm

2 Nm

Running angle

90 °

90 °

Runing speed

2 min / 90 °

2 min / 90 °

FEATURES

Alternative running speed Optional auxiliary micro switch Operating mode

15 s, 30 s, 1 min, 4 min and 8 min / 90 <° l 2-point, 3-point or proportional

1 min / 90 <° x 3-point or proportional

Indication of actual valve position

Various installation sets available l

LED indication of turning direction

l

x

Na damage in case of valve blocking

Na damage in case of valve blocking

Built in permanent clutch (enables manual valve turning)

l

l

Silent operation

l

l

Maintenance free l

Maintenance free l

Installation onto rotating mixing valves

Reliable operation

Maintenance Simple and easy installation

Esbe - old type l

ORDER TABLE FOR NON-STANDARD ACTUATOR MODELS AVC 15 3 1M 1 1 PRODUCT NAME PROMIX® AVC - actuator for rotating mixing valves

TORQUE 05 - 5 Nm 10 - 10 Nm 15 - 15 Nm

OPERATION MODE 2 - 2-point B - 2-point + auxiliary switch 3 - 3-point (default) C - 3 point + auxiliary switch Y - 0 (2) ÷ 10 V or 0 (4 )÷ 20 mA control signal

RUNNING SPEED 1M - 1 min 2M - 2 min (default) 4M - 4 min 8M - 8 min 15 - 15 sec 30 - 30 sec

POWER SUPPLY 1 - 230 V ~, supplied without power cord 2 - 230 V ~, supplied with a 2 meters power cord (default) 3 - 24 V ~, supplied without power cord 4 - 24 V ~, supplied with a 2 meters power cord 5 - 24 V ac/dc (only for operation mode type Y)

HANDLE TYPE 1 - knob (default for AVC05) 2 - handle (default for AVC10, AVC15) 3 - valve position indicator only

86


TECHNICAL DATA

Torque

AVC05

AVC10

AVC15

AVE

5 Nm

10 Nm

15 Nm

2 Nm

Running angle 90 ° Running speed Power supply Rated power Control signal 2 point, 3 point, proportional Auxilliary switch Power consumption 2,5 VA - 4 VA

90 ° 15 s, 30 s, 1min, 2 min, 4 min, 8 min 230 VAC, 24 VAC, 50 Hz 2,5 - 4VA

1 VA

2 point, 3 point, proportional

3 point, proportional

adjustable (250 VAC, 3A) 2,5 VA - 4 VA

Degree of protection Safety class

IP 42 II for 230 VAC power supply, III for 24 VAC power supply

Dimensions with knob (w × l × h)

84 x 101 x 96 mm

Dimensions with handle (w × l × h)

84 x 101 x 99 mm

Dimensions with indicator (w × l × h)

84 x 101 x 82 mm

Color / material Cable length Weight (actuator and mountig kit) Complies with directives

67 x 82 x 54 mm

dark gray / PC

black / PC

2m

1m

390 g - 860 g

275 g

LVD: 2006/ 95 /EC, EMC: 2004/ 108 /EC, RoHS2: 2011/65/EU

Ambient temperature

0 ÷ 50 °C

Storage temperature

-20 ÷ 70 °C

Package unit

1 min, 2 min

30 pcs.

60 pcs.

87


88 mm

DIMENSIONS

101 mm

1ASCAVMSC000+NN0

Centra ZR/DR

101 mm

1ASCAVMSD000+NN0 Centra DRU 1ASCAVMSE000+NN0

Siemens VBI, VBF

1ASCAVMSF000+NN0

Wita, Meibes

1ASCAVMSH000+NN0 Firšt 1ASCAVMSI000-NN0

Honeywell V544, …, V543

1ASCAVMSJ000-NN0

Paw K32, K33, K34

1ASCAVMSK000+NN0

Danfoss HRB, HFE, HRE

1ASCAVMSP000+NN0

ISO5211/F03/H-9

1ASCAVMSQ000+NN0 ISO5211/F03/L,D-9 1ASCAVMSR000+NN0 ISO5211/F05/L,D-11

88

mm 10184 mm 101 mm

84 mm

ACTUATOR SIZE SELECTOR 75 mm

75 mm

1ASCAVMSB000+NN0

9275 mm mm

101 mm

1ASCAVMSG000+NN0 Esbe VRG for 10Nm+ Esbe, Seltron, Somatherm, Acaso, IVAR, WIP, PAW, BRV, IMIT, Hora, Barberi, Olymp, Hoval

92 mm

92 mm

1ASCAVMSA000+NN0

Esbe, Seltron, Somatherm, Acaso, mm IVAR, WIP, PAW,101 BRV, IMIT, Hora, Barberi, Olymp, Hoval

84 mm 101 mm 101 mm

84 mm

Ordering codes for basic types MANUFACTURER

88 mm 92 mm

88 mm

88 mm

AVC actuators can be mounted on a very wide range of mixing valves from different101 mm manufacturers. For this purpose various installation sets are available.

CODE

101 mm

Actuator

BRASS 101 mm

VALVES DN Size Inch Size 84 mm

75 mm

COMPATIBLE WITH MIXING VALVES

CAST IRON 84 mm VALVES DN Size 101 mm Inch Size

AVC05

DN40

1 1/2”

DN32

5/4”

AVC10

DN80

3 1/4”

DN65

2 1/2”

AVC15

DN125

5”

DN100

4“


ACTUATOR AVC WITH BALL VALVE

ORDERING CODES Ordering codes for basic types Actuator - PROMIX® AVC05 5 Nm, 2 min., 3-point, 230 V

Ordering codes for basic types

Code: 1AVC0532M210-030 Actuator - PROMIX® AVC05R 5 Nm, 1 min., 2-point, 230 V Code: 1AVC0521M210-030 Actuator - PROMIX® AVC05S 5 Nm, 2 min., 3-point, 230 V with auxiliary switch Code: 1AVC05C2M210-030

Actuator - PROMIX® AVC05R 5 Nm, 1 min., 230 V with 2p ball valve DN15 Code: 1AVC0521M22215-0 Actuator - PROMIX AVC05R 5 Nm, 1 min., 230 V with 2p ball valve DN20 ®

1AVC0521M22220-0

Actuator - PROMIX® AVC15 15 Nm, 2 min., 3-point, 230 V Code: 1AVC1532M220-030 Actuator - PROMIX® AVC10Y 10 Nm, 1 min., Proportional, 24 V Code: 1AVC10Y1M510-030

Actuator - PROMIX® AVC05R 5 Nm, 1 min., 230 V with 2p ball valve DN25 Code: 1AVC0521M22225-0 Actuator - PROMIX® AVC05R 5 Nm, 1 min., 230 V with 2p ball valve DN32 Code: 1AVC0521M22232-0 Actuator - PROMIX® AVC05R 5 Nm, 1 min., 230 V with 3p ball valve DN15 Code: 1AVC0521M22315-0 Actuator - PROMIX® AVC05R 5 Nm, 1 min., 230 V with 3p ball valve DN20 Code: 1AVC0521M22320-0 Actuator - PROMIX® AVC05R 5 Nm, 1 min., 230 V with 3p ball valve DN25 Code: 1AVC0521M22325-0

89


Comfort at the highest level.

90


RCD, DD2+ Room units


RCD, DD2+ Room units

HIGHLIGHTS yy Modern and stylish appearance. yy Large illuminated display. yy Compatible with all Seltron controllers.

Room unit RCD is designed for simple and comfortable room temperature adjustment and controller operation mode selection. Room unit is mounted in central living room, where are the most relevant temperature and climatic conditions of the building. The same way as with room unit, all adjustments can also be made with application Clausius on smart devices. For this purpose an internet connection to SeltronHome platform is needed. Room units RCD is compatible with all modern Seltron controllers, such as AHC, CMP, WDC, WXD, KXD, KPD, KUD and KWD. Modern and discreet shape enables elegant integration of room unit into virtually any interior design. Sophisticated construction simplifies installation and connection. Room unit RCD features big illuminated LCD display which lights up automatically if person approaches the room unit in dark. But the room temperature isnâ&#x20AC;&#x2122;t the only value that RCD can monitor. It can also measure and analyse climatic conditions of the living room. Built-in are humidity, illuminance, air pressure and air quality sensors. That way RCD can measure quality of living climate and warn user if living room needs fresh air.

92


USER FUNCTIONS Party operation mode Party operation mode is selected to extend daily or comfort mode of space heating. You can also set the time of the Party operation mode. ECO operation mode

ECO

ECO function allows heating at a lower or energy saving temperature. You can also set the time of the Eco operation mode.

One-time domestic hot water warming The function switches on the domestic hot water heating instantly.

Holiday operation mode The function allows the heating to be set at a specific energy saving temperature for a specified number of days.

93


RCD1

RCD1 Premuim

RCD2

RCD2 Premium

DD2+

Day temperature setting

l

l

l

l

l

Night temperature setting

l

l

l

l

l

Display of actual and setpoint temperature

l

l

l

l

l

l

l

l

l

l

l

Party and Eco function with adjustable duration

l

l

l

Holiday mode up to 99 days

l

l

l l

Room units

FEATURES

Operation mode selection Overview of temperatures and controller operation mode

l

l

Possibility to connect additional temperature sensor

l

l

l

l

Illuminated display

l

l

l

l

Humidity sensor

l

l

Illumination sensor

l

l

Pressure sensor

l

l

Air quality sensor

l

l

TECHNICAL DATA RCD1

RCD1 Premuim

RCD2

RCD2 Premium

Power supply

bus communication line

Consumption

N. A.

Temperature sensor

RTD Murata NTC (10 kE)

Degree of protection

IP 30 according to EN 60529

Safety class

III according to EN 60730-1

Housing Dimensions (w × l × h)

I= 0,022 mA; P= 0,066 mW

PC thermoplastics, white

ABS thermoplast, white

82 × 125 × 15,5 mm

34 × 72 × 112 mm

Ambient temperature

0 ÷ 40 °C

Storage temperature

-20 ÷ 65 °C

Weight Package unit

94

115 g

DD2+

135 g

115 g 30 pcs

135 g

98 g


ORDERING CODES Room unit RCD1 Code: 1RCD1-040 Room unit RCD1 Premium Code: 1RCD1P-040 Room unit RCD2 Code: 1RCD2-040 Room unit RCD2 Premium Code: 1RCD2P-040 Room unit DD2+ Code: 2DD2+-010

95


Comfort at the highest level. 96


Room thermostats


Room thermostats HIGHLIGHTS yy Weekly program timer. yy Logic for optimization of on/off time. yy Night, day and comfort temperature. yy Display of actual and requested temperature.

Room thermostats are modern and powerful devices intended for controlling the temperature in apartments, houses, business buildings or for zone temperature control in large buildings. The main advantages of the room thermostats are easy installation and simple use. They convince through a large spectrum of built-in functions like ECO, PARTY and holiday mode.

98


USER FUNCTIONS Party operation mode Party operation mode is selected to extend daily or comfort mode of space heating. You can also set the time of the Party operation mode. ECO operation mode

ECO

ECO function allows heating at a lower or energy saving temperature. You can also set the time of the Eco operation mode. Holiday operation mode The function allows the heating to be set at a specific energy saving temperature for a specified number of days.

Heating and cooling Depending on the season you can set either the heating or air-conditioning mode.

HEATING SYSTEM PROTECTION Room thermostat feature frost protection function.

REMOTE POWER-ON External control signal allows activation of day temperature mode.

99


Room thermostat

T1

ST2R

ST2RDR

Number of hydraulic schemes Heating or cooling

3 l

5 l

8 l

Temperature setting area 10 °C ÷ 30 °C

l

l

l

Fixed time programs

2

Electric floor heating with maximal floor temperature limitation

4 l

6 l

Optional room temperature sensor

l

l

FEATURES

USER FUNCTIONS Function PARTY

l

l

l

Function ECO

l

l

l

HOLIDAY mode

l

l

l

Day and night temperature setting

l

l

l

Comfort temperature setting

l

l

Instant d.h.w. warming

l

l

Logic for optimized start of heating (Fuzzy logic)

l

l

l

l

l

l

l

l

l

Installation on the wall or Wallbox

l

l

l

Easy installation and connection

l

l

l

l

l

l

HEATING SYSTEM PROTECTION l

Frost protection Choice of keyboard and knob locking DATA DISPLAY Display of actual and requested room temperature SETTINGS AND INSTALLATION

REMOTE ACCESS Remote activation via telephone

TECHNICAL DATA T1

ST2R

Power voltage

2 Batteries LR03, tip AAA

Relay output

6 (2) A / 230 V~

Consumption

2x 6 (2) A / 230 V~

I= 0,022 mA; P= 0,066 mW

Degree of protection

IP 30 according to EN 60529

Safety class Operation mode

II according to EN 60730-1 P– Controller (ON / OFF)

Temperature sensor

PID– Controller (ON / OFF)

ABS thermoplastics, white

Dimensions (w × l × h)

34 × 72 × 112 mm

Ambient temperature

0 ÷ 40 °C

Storage temperature

-20 ÷ 65 °C

Package unit 100

P or PID– Controller, 2 or 3 - point

RTD Murata NTC (10 kE)

Housing

Weight

ST2RDR

109 g

114 g 30 pcs

123 g


Room thermostats

T1

ST2R

ST2RDR

l

l

l

Solar collectors

HEAT SOURCE

Solid fuel boiler Boiler with pellet burner Oil boiler Combined boiler for liquid and solid fuel Gas boiler Heat pump Heat accumulator l

Boiler with integrated d. h. w. tank

REGULATED ELEMENTS

Direct heating circuit

l

l

l l

Mixing heating circuit l

l

Floor heating

l

l

Domestic hot water warming

l

l

Radiators

l

101


HYDRAULIC SCHEMES The illustrated hydraulic schemes are supported in the following room thermostat: T1.

The illustrated hydraulic schemes are supported in the following room thermostat: ST2R.

230 V ~

The illustrated hydraulic schemes are supported in the following room thermostat: ST2RDR.

102


ORDERING CODES Room thermostat T1 Code: 1T1-000

Room thermostat ST2R Code: 2ST2R-510

Room thermostat ST2RDR Code: 2ST2RDR-511

103


Accuracy is our virtue.

104


Temperature sensors


OUTDOOR SENSOR The AF sensor is intended for outdoor-temperature measurement. Sensor

Dimensions

Lenght

Code

AF/Pt

49 mm x 26 mm x 14 mm

-

1AFPT-000

SURFACE SENSOR The VF surface-sensor is intended for pipe-temperature measurement. Sensor

Dimensions (housing)

Cable Lenght

Code

VF/Pt

23 mm x 14 mm x 42 mm

Silicone (max. 180 °C) - 3 m

1VFPT-000

IMMERSION SENSOR The TF is an immersion sensor for boiler, storage tank, solar collectors and other temperature measurements. Sensor

Dimensions

Cable Lenght

Code

TF/Pt

Ø 6mm x 50 mm

Silicone (max. 180 °C) - 3 m

1TFPT-000

UNIVERSAL IMMERSION SENSORS The VF2 are universal immersion sensors for pipe and other temperature measurements. They have a threaded plug R1/4 and an adaptor for installation into the TH1 immersion tubes.

106

Sensor

Dimensions (housing)

Immersion depth

Code

VF2/Pt -40

49 mm x 26 mm x 114 mm

40 mm

1VF2PT40-000

VF2/Pt -90

49 mm x 26 mm x 114 mm

90 mm

1VF2PT90-000

VF2/Pt -120

49 mm x 26 mm x 114 mm

120 mm

1VF2PT120-000

VF2/Pt -200

49 mm x 26 mm x 114 mm

200 mm

1VF2PT200-000


ROOM SENSOR The PS10 room sensor is used for room temperature measurement. Sensor

Dimensions

Cable Lenght

Code

PS10/Pt

73 mm x 28 mm x 73 mm

-

2PS10PT-510

TUBE TH1 The TH1 tube is used to install the temperature sensor into pipelines and for other applications. The TH1 immersion tubes have a threaded plug G1/2. Tube

Dimension outside / inside

Immersion depth

Code

TH1-40

Ø 9 mm / Ø 7 mm

40 mm

1TH14012-000

TH1-90

Ø 9 mm / Ø 7 mm

90 mm

1TH19012-000

TH1-120

Ø 9 mm / Ø 7 mm

120 mm

1TH112012-000

TH1-200

Ø 9 mm / Ø 7 mm

200 mm

1TH120012-000

TUBE TH2 The TH2 tube is used to install the temperature sensor into the solar collector. They have a threaded plug R1/2. Tube

Dimension outside / inside

Immersion depth

Code

TH2-100

Ø 8 mm / Ø 6,9 mm

100 mm

1TH210012-000

TH2-190

Ø 8 mm / Ø 6,9 mm

190 mm

1TH219012-000

EXHAUST SENSOR Exhaust gases temperature sensor. Sensor

Dimensions

Cable Lenght

Code

CF/Pt

Ø3 x 73 mm

Metal shielded (max. 400 °C) - 1,5 m

1CFPT-000

107


108


OEM solutions Selling terms


OEM SOLUTIONS In company Seltron we are also specialized in producing controllers for costumers requirements. So we offer many ways for OEM (Original Equipment Manufacturer) business cooperation. Nowadays quality is not enough to be competitive. So what should you do to stand out from your competitors? Simple, become exclusive, become different from others and work on your visibility with your solutions in means of personalized OEM products. Try Seltrons offer of exclusive OEM partnership.

SELTRON OEM ADVANTAGES yy Seltron Simplicity Solutionsâ&#x201E;˘ package. yy More than 20 years of experience in manufacturing controllers. yy Technical support and service. yy Established solutions. yy Flexible production. yy Latest technology. yy Seltron invented software solutions.

Icones Company Logo Screen Color

Company Logo Controller Type Housing Color

A FEW OPTIONS BASIC - OEM

BASIC PLUS - OEM

PREMIUM- OEM

Your Logo print on the housing

l

l

l

Logo on the display

l

l

l

Neutral user manuals or printed with your logo

l

l

l

Integrated Seltron Simplicity Solutions (see page 7, 8)

l

l

l

Your software adjustments for Schemes and parameters

l

l

Creating your own icons

l

l

Changed form of the controller housing and keyboards

l

Choice of displayâ&#x20AC;&#x2122;s color

l

110


SELLING TERMS GENERAL TERMS The sale of products and services is executed solely in accordance with these general conditions of sale. Purchase conditions of our buyers are with this excluded and they are not being accepted also in cases, when we not disapprove them explicitly. All eventual discrepancies from these general conditions for sale must be prior in written approved by our part. The general conditions for sale are a component part of pro-forma invoices, invoices, offers and contracts. All receipt orders must be in written shape and the receipt orders are valid only with our written confirmation. Also confirmations by fax or e-mail are thought as written confirmed orders. Content of our confirmation is at least valid. In case, that the buyer untermands the order is he obligated to refund all costs to the company, which occurred concerning this order till day of otice.

DELIVERY TIMES Delivery times are orientating and are not binding, unless it was written confirmed otherwise. Delivery time starts with the day of order confirmation and runs out with the day of delivery of the product or fulfillment of the service to the buyer. Delivery times can be proportionally prolonged in case of unpredictable barriers, which occurred despite our will, and they are such nature, that they had important impact on fulfillment of ligations. Beginning and the end of the barriers are we obligated to report immediately to the buyer. Based on this barriers the buyer can’t file a claim for return of damage occurred next to exceeding of delivery time. Partial deliveries are admissible. Confirmed delivery time is extended easily in case of additional change of buyers order. In case, that the buyer in frame of the delivery time isn’t capable to take over the goods or arranged service, we are justified to issue a bill for value of goods or services. At the same time we are justified to calculate the costs of storage of goods and for occurred costs issue a bill. Transition of responsibility for products applies with the day of takeover of goods, delivered form the transporter. In case, when we don’t carry the costs of transport, transmits the risk of loose and injury of goods on the buyer with handing over to the transporter, forwarder or the client personally.

TERMS OF PAYMENT The bill is payable in term and on manner, that was arranged next to conclusion of the contract or confirmed next to receipt of order. As the date of payment, is counted the day of arrival of buyer’s means at our transactional bank account at a commercial bank. If the purchase price is paid within 8 days from issuing of the bill, then to the buyer is confessed additional discount in height of 2 percent. In case, that the buyer does not pay the purchased money in arranged pay time period, are we justified to charge default interests. In case of unsuccessful agreement concerning settlement of claims, we will by preliminary written admonition, exact payment with lawsuit.

OWNERSHIP We reserve the right of ownership on delivered products till the entire settlement of the bill that means including with all side claims, eventual interests and costs. Only when the claim from realized delivery of products or services is in whole settled, ownership transmits on the buyer. Buyer is in time till the settlement of the bill obligatory to treat the goods as a good master. When the buyer does not pay the goods in arranged time period, he may not sell it to other buyer because of reservation of property right to complete payment. We reserve the right to property to all offered supplemental e.g. sketch, plans etc. every documentation that we sent to the buyer may not be handed over to the third person without written permission.

111


SELLING TERMS PROTECTION OF DATA The buyer is bound with individual information’s and business secrets concerning the fulfillment of the contract to act confidentially and not hand over to third party documents, drawings, sketches or similar supplements without written consent.

CLAIM The buyer is obligated for every damage, that occurred by transport next to delivery to claim back to transporter and to gain his confirmation. At the same time is the buyer obligatory to immediately notify each damage in written shape to seller. In case of a justified claim, we will resolve this most lately in 30 days. In case, that the claim is not possible to resolve in this time period, we will notify the buyer of the new time period and the manner of solution of this claim in written shape. The buyer is obligated to restrain the products till solution of the claim and act with them as a good owner, otherwise he is responsible for occurred damage.

GUARANTEE All delivered products have a guarantee of 24 months from sale of the device or mostly 30 months from the day of the sale of the product. The buyer is obligated to consider the instruction for use and ontage, which are attached to the product. The claim can’t be put in by ncorrect and unprofessional use or montage of the product. In these cases the guarantee stops being valid. The guarantee agreement is appointed with the contract or supplemental to the contract.

SERVICING Servicing of the equipment does the service SELTRON d.o.o. in time of the guarantee and outside the guarantee age. Conditions of the servicing are determined considering the type of goods.

QUALITY OF GOODS The quality of goods must suit the valid standards and norm for ndividual product or must be in accordance with individual technical demands, by which the product is made.

SOLVING OF DISPUTES We will try to solve all disputes consensually. In case, that the disputes won’t be possible to abolish consensual, is for solving of them competent the Court of justice in Maribor.

112


Submitted from:

SELTRON d.o.o.

Tržaška cesta 85 A SI-2000 Maribor Slovenia Phone: + 386 (0)2 671 96 00 Fax: + 386 (0)2 671 96 66 Email: info@seltron.eu Web: http://www.seltron.eu