SSEDTA for Eurocode 4

Page 239

Shear connection design 239

Basic rules – Connectors should be ductile – Plastic design of shear connection is possible even if global analysis is elastic, provided that the end cross-sections of the critical length to be designed are at least Class 2 – In hogging moment regions, use of full shear connection is recommended – In sagging moment regions, partial shear connection may be applied