THIS IS A BRIEF COLLECTION OF REVIT BIM WORK I PRODUCED THAT SPANS CONSTRUCTION DOCUMENT, DESIGN DEVELOPMENT AND SHCEMATIC PHASES. DETAILING IS ALSO INCLUDED. EACH PAGE CONTAINS A TITLE / PURPOSE OF THE DRAWING ON THE BOTTOM OF THE PAGE. ALL WORK IS SOLELY MY OWN AND WAS PERFORMED FOR BOULDER ASSOCIATES ARCHITECTS IN BOULDER, CO UNDER THE SUPERVISION OF LICENSED PROFESSIONALS. RYAN HOUSER M.ARC 2017 NC STATE UNIVERSITY


EXISTING AND NEW FIT PLAN FOR FOURTH FLOOR ERC


PROJECT NUMBER

173121.00 RENO TYPE EXISTING REFRESH MAJOR RENOVATION TOTAL

B

C

D

E

STORAGE 15 SF

11 10 CONFERENCE 296 SF

OFFICE 130 SF

OFFICE 127 SF

OFFICE 136 SF

OFFICE 115 SF

SHAFT 26 SF

GROUP 188 SF

GROUP 209 SF GROUP 238 SF

Area Schedule (Reno Types) Name

OFFICE 127 SF

JAN. 53 SF

OFFICE 137 SF

SHAFT 69 SF

TLT. / SHR. 86 SF

MEDS 92 SF

DOUBLE PATIENT 219 SF

ELEV #1

WORK 138 SF

GROUP 223 SF

SEATING

STORAGE 61 SF

RECEPTION 108 SF

WOMEN 144 SF

CLINICAL SUPPLY 60 SF

ELEC. 49 SF SEATING

WORK 109 SF

ELEVATOR CONTROLLER 202 SF

ELECTRIC FIREPLACE

CORR.

4

DOUBLE PATIENT 230 SF

CORR.

DOUBLE PATIENT 229 SF

DOUBLE PATIENT 242 SF

LAB 77 SF

L

2

EXERCISE PHYSIOLOGY LAB 580 SF

FP

ELEC. 114 SF

CORR.

ST. T. 58 SF QUIET ZEN 118 SF O2 STOR. 56 SF

COMM. 70 SF

SMOKE BARRIER

12 FULL 'E' TANKS MAX PER SMOKE COMPARTMENT

3

STORAGE 64 SF

PATIENT STORAGE 59 SF

KIT. TLT. 67 SF

STAFF CORR.

STAFF BREAK 229 SF KIT. LOCKER 54 SF

JAN. 50 SF

KIT. STOR. 53 SF

CORR.

KITCHEN 605 SF

ELEV #4

TRASH / RECYC. 85 SF

ELEV #3 STAIR 2

CLEAN LINEN 133 SF

DRY STORAGE 67 SF

FLOOR 5 FIT PLAN 1/8" = 1'-0"

2 1

COOLER 42 SF

INPATIENT

KIT. OFFICE 68 SF

FREEZER 29 SF

SPA / BATH 631 SF

SECL. TLT. 54 SF SECL. VEST. 171 SF

SECLUSION 107 SF

AUXILIARY TOWER?

MEDS 113 SF

TLT / SHR 80 SF

SECLUSION 106 SF

TLT / SHR 88 SF

SERVICE / SUPPORT

QUIET ZEN 80 SF

NURSE STATION 70 SF

SEATING

DOUBLE PATIENT 234 SF

DOUBLE PATIENT 235 SF

DOUBLE PATIENT 237 SF

DOUBLE PATIENT 224 SF

TEAM OFFICE 145 SF

STORAGE 95 SF

DOUBLE PATIENT 224 SF TV

DOUBLE PATIENT 236 SF

PATIENT ROOM

PROJECT

ERC EVERGREEN BETR

PUBLIC / COMMON

HSKP 80 SF

EXAM 165 SF

DOUBLE PATIENT 226 SF

DEPARTMENT LEGEND

CIRCULATION

ELEV #5

CORR.

FP

1/16" = 1'-0"

Boulder Associates, Inc. Architecture + Interior Design 1426 Pearl Street, Suite 300 Boulder , Colorado 80302 303.499.7795 www.boulderassociates.com

SOILED UTILITY 80 SF

SHAFT 81 SF

14 BEDS

1

FLOOR 5

DINING 1655 SF

TEACHING KITCHEN

CART WASH 50 SF

LAUNDRY 116 SF

EQUIPMENT LAUNDRY 113 SF 116 SF

CLEAN LINEN 15 SF

DOUBLE PATIENT 242 SF

TELE. 70 SF

CLEAN SUPPLY 70 SF

SHAFT 81 SF

COMMUNITY 630 SF TV

K

LOBBY 352 SF

WORK 160 SF

NURSE STATION 115 SF

J

STOR. 70 SF

WELCOME 164 SF

CORR.

MEN 144 SF

H SMOKE BARRIER

LOCKERS AND COAT HOOKS FOR PHP

CORR.

JAN. 23 SF

IT 66 SF

G

OFFICE 166 SF

WELCOME 140 SF

ELEV #2

ELEV LOBBY 171 SF

5.8

5

OFFICE 162 SF

OFFICE 140 SF

DOUBLE PATIENT 237 SF

6

ART THERAPY 388 SF OFFICE 109 SF

TLT. / SHR. 96 SF

6.2

Calculating...

STAIR 1B

DOUBLE PATIENT 216 SF

6.4

DATE

CLOSET 40 SF

STORAGE 38 SF

6.8

DESCRIPTION

CORR.

SPA / BATH 688 SF

7

REVISIONS

REV

REFRESH

MULTIPURPOSE 907 SF

CORR. 907 SF

7.7

Area

EXISTING 3194 SF MAJOR RENOVATION 18600 SF REFRESH 8021 SF 29815 SF

MAJOR RENOVATION

REFRESH 1770 SF

OFFICE 115 SF

OFFICE 124 SF

9 8

C:\Revit Local Files\173121.00 ERC Evergreen BETR-A17 Central_rhouser.rvt

2018.02.20

RENOVATION TYPES

STORAGE 77 SF

STORAGE 79 SF

OFFICE 151 SF

TTLBv.20150126 2/20/2018 10:29:41 AM

DATE

F

EXISTING

SHAFT 37 SF

DRAWN BY

JG

COMMUNITY 587 SF

SHAFT / VERTICAL CIRCULATION

ADDRESS

1830 FRANKLIN STREET SUITE 500 DENVER, CO

Calculating...

RENOVATION 28 BEDS • 14 DOUBLE OFFICE • 14 OFFICES • 4 GROUP • 2 WELCOME • 1 CONFERENCE

FIT PLAN

SHEET TITLE

FIT PLAN

ELECTRIC FIREPLACE

SHEET NUMBER

14 BEDS

FP

THIS LINE IS 1 INCH LONG WHEN PRINTED TO FULL SCALE

A

AREA SF COST FACTOR COST 3194 $1.5 $8021 $35.00 1.5 $421,102.50 18600 $250.00 1.5 $6,975,000.00 26621 $277.83 1.5 $7,396,102.50

NEW FIT PLAN FOR MAIN FLOOR ERC


LIGHTING FIXTURE SYMBOLS

B

C

D

E

10

F

RECESSED WALL WASHER FIXTURE. 'D' INDICATES DIMMING.

D.

RECESSED INDIRECT FIXTURE - 2x2 OR 2x4 AS INDICATED

STORAGE SHAFT

OFFICE

CONFERENCE

OFFICE

STORAGE

RECESSED PRISMATIC LENS FIXTURE - 2x2 OR 2x4 AS INDICATED

OFFICE

173121.00 DRAWN BY

RH DATE

2018.02.20

REVISIONS

REV

MULTIPURPOSE

STORAGE

DESCRIPTION

DATE

RECESSED PARABOLIC LENS FIXTURE - 2x2 OR 2x4 AS INDICATED

OFFICE

WALL-MOUNTED FIXTURE

OFFICE

OFFICE UNDERCABINET LIGHT

CLOSET

SHAFT

PROJECT NUMBER

RECESSED DOWNLIGHT FIXTURE. 'D' INDICATES DIMMING.

D.

GROUP COVE LIGHTING

CORR.

GROUP

ART THERAPY SUSPENDED LINEAR FIXTURE

JAN. GROUP

OFFICE

OFFICE

OFFICE

LARGE DECORATIVE PENDANT

SMALL DECORATIVE PENDANT

OFFICE

CORR.

9 8

OFFICE

ILLUMINATED EXIT SIGN

XRAY

7.7

SHAFT

NURSE CALL LIGHT

GROUP

STAIR 1B

SPA / BATH

'XRAY IN USE' LIGHT

WORK CEILING ACCESSORIES CUBICLE CURTAIN TRACK. SEE ACCESSORY SCHEDULE FOR MANUFACTURER INFORMATION.

OFFICE STORAGE

G

J

K

L

OFFICE SPRINKLER HEAD

7 ELEV #1

TLT. / SHR.

6.8

TELE.

WELCOME

ELEV #2

DOUBLE PATIENT CORR.

TLT. / SHR.

6.4 MEDS

NURSE STATION

CLINICAL SUPPLY

MEN

CLEAN SUPPLY

LAB

JAN.

WOMEN

DOUBLE PATIENT

DOUBLE PATIENT

ST. T.

DOUBLE PATIENT

+66"

DOUBLE PATIENT

ELEV #5

QUIET ZEN

ELEV #4

ELEV #3

A

KITCHEN

DRY STORAGE

COOLER KIT. OFFICE

PROJECT

SECLUSION

SPA / BATH

3. 4.

TLT / SHR SECL. VEST.

DESCRIPTION

MANUFACTURER

2'x2' ACOUSTIC PANEL CEILING

2'x2' HIGH STC ACOUSTIC PANEL CEILING ARMSTRONG GYP. BOARD CEILING WOOD CEILING ARMSTRONG

ARMSTRONG

MODEL

COMMENTS

NOTES 1. 2.

TEAM OFFICE

SECLUSION

QUIET ZEN

TLT / SHR

MEDS

ERC EVERGREEN BETR

AREA NOT IN PROJECT SCOPE

DOUBLE PATIENT

STORAGE

TYPE

GYP. BD. CEILING

HSKP

SECL. TLT.

4

(E) APC-1A

WINDOW TREATMENT SYMBOL

ACOUSTIC PANEL CEILING - 2x2 OR 2x4 AS INDICATED.

TRASH / RECYC.

STAIR 2

1

FABRIC (#)

FREEZER

EXAM

APC-2A GYP-1 WD-1

FINISH TYPE, WHERE APPLICABLE CEILING HEIGHT

CLEAN LINEN

O2 STOR.

CEILING TYPES

CEILING TYPE, SEE CEILING SCHEDULE

TREATMENT STYLE

CORR.

ELEC. CORR.

P# 9'-0"

KIT. STOR.

LAUNDRY

LAUNDRY

APC #

STAFF BREAK KIT. LOCKER

SOILED UTILITY

STAFF CORR. EQUIPMENT

CORR.

5

KIT. TLT.

PATIENT STORAGE CART WASH

Boulder Associates, Inc. Architecture + Interior Design 1426 Pearl Street, Suite 300 Boulder , Colorado 80302 303.499.7795 www.boulderassociates.com

CEILING GRAPHICS

STORAGE

COMM.

SHAFT

SHAFT

CLEAN LINEN

CORR.

RETURN GRILLE - SEE MECHANICAL

EXHAUST - SEE MECHANICAL

ELEVATOR CONTROLLER

ELEC. COMMUNITY

TEACHING KITCHEN

WORK

RECEPTION

WORK

5.8

SUPPLY DIFFUSER - SEE MECHANICAL

WELCOME

CORR.

DOUBLE PATIENT

CEILING ACCESS PANEL

DINING

JAN.

IT

6

SPEAKER

EXERCISE PHYSIOLOGY LAB

LOBBY

STORAGE

6.2

STOR.

ELEV LOBBY

DOUBLE PATIENT

C:\Revit Local Files\173121.00 ERC Evergreen BETR-A17 Central_rhouser.rvt

H

NURSE STATION

GENERAL PAINT SHALL BE P3, U.N.O. PAINT AND WALLCOVERING INDICATED FOR SOFFITS SHALL WRAP ALL EXPOSED SURFACES OF SOFFIT, U.N.O. ALL SIDES OF SOFFITS ABOVE UPPER CABINETRY SHALL BE PAINTED TO MATCH ADJACENT WALL FINISH, U.N.O. REFER TO MATERIALS LIST ON SHEET ID1.1 FOR PAINT AND WALLCOVERING INFORMATION.

DOUBLE PATIENT

3

DUNE #1774

24" X 24" X 3/4" ANGLED TEGULAR LAY-IN TILE. 15/16" XL PRELUDE SUSPENSION SYSTEM, WHITE 24" X 24" X 3/4" ANGLED TEGULAR LAY-IN TILE. SEE MATERIALS LIST ON ID1.1 FOR PAINT INFORMATION. WOODWORKS 96" X 3 3/4" X 3/4" PLANKS WITH 3/4" REVEAL. 5370 12' HD CONCEALED LINEAR LINEAR CARRIERS WITH FACTORY APPLIED INTEGRAL CLIPS FOR NOMINAL 4 1/2" MODULES VENEERED AND FACTORY APPLIED FELT TO COVER REVEALS. AT LOCATIONS WHERE WD-1 IS PLANKS, BELOW FIELD CEILING, PROVIDE 6"H 5660W1 WOOD TRIM TO MATCH. ALL #6440W1 COLOR: MOUNTING CLIPS TO BE BLACK NLC LIGHT CHERRY

FIT PLAN

CORR.

DOUBLE PATIENT

DOUBLE PATIENT

DOUBLE PATIENT

DOUBLE PATIENT

ADDRESS

1830 FRANKLIN STREET SUITE 500 DENVER, CO

+66"

DOUBLE PATIENT

COMMUNITY

OVERALL REFLECTED CEILING PLAN FOR ERC

OVERALL FIFTH FLOOR REFLECTED CEILING PLAN

2 A

1

1

SHEET NUMBER B

FLOOR 5 OVERALL

A2.45

1/8" = 1'-0"

C D

A2.45

THIS LINE IS 1 INCH LONG WHEN PRINTED TO FULL SCALE

TTLBv.20150126 2/20/2018 10:29:18 AM

SHEET TITLE


PROJECT NUMBER

173121.00

A

B

C

D

E

11 10

DRAWN BY

F

RH DATE

2018.02.20

STORAGE OFFICE

STORAGE

OFFICE OFFICE

OFFICE

REVISIONS

OFFICE

REV

OFFICE

OFFICE

OFFICE

DESCRIPTION

DATE

FOOTHILLS ROOM

STORAGE

OFFICE STORAGE

WORK

OFFICE

OFFICE

9 8

OFFICE

OFFICE

OFFICE

OFFICE

JAN.

ART THERAPY

OFFICE

OFFICE OFFICE SINGLE PATIENT

STAIR 1B

OFFICE

7.7

WORK OFFICE DOUBLE PATIENT CASE MANAGERS

DOUBLE PATIENT

ELEVATOR #1ELEVATOR #2

OFFICE

SPA / BATH

RECEP.

WORK

H

J

OFFICE

DOUBLE PATIENT

OFFICE ELEVATOR LOBBY DOUBLE PATIENT

6.4 6.2 6

MAINT. / EQPT CLEAN LINEN STORAGE

COMMUNITY / LIBRARY

STORAGE

ELEVATOR EQUIPMENT

WORK MENS

5.8 DOUBLE PATIENT

NURSE STATION

COMM.

MEDS

ELECTRICAL

EXAM

PRIVATE BATH

DOUBLE PATIENT

CLEAN LINEN

DOUBLE PATIENT

6

STAFF BREAK

ELECTRICAL

ELEVATOR #5 ELEVATOR #4ELEVATOR #3

STAIR 2

TRASH / RECYC.

EM SUPPLIES

VISTA ROOM

C:\Revit Local Files\173121.00 ERC Evergreen BETR-A17 Central_rhouser.rvt

TEACHING KITCHEN

DOUBLE PATIENT

MOUNTAIN ROOM

5.8

OFFICE

WORK

NURSE STATION

PHONE

ACCESS. BATHING SUITE

HSKP STORAGE

5

BLUESKY ROOM

STORAGE

ADDRESS

MASSAGE

DOUBLE PATIENT

DOUBLE PATIENT

DOUBLE PATIENT

DOUBLE PATIENT

1830 FRANKLIN STREET SUITE 500 DENVER, CO

SINGLE PATIENT

SINGLE PATIENT

STORAGE

WORK

DOUBLE PATIENT

3

DOUBLE PATIENT

1 FLOOR 5 - existing

FIT PLAN

SHEET TITLE

2

EXSTG. 1/8" = 1'-0"

PROJECT

ERC EVERGREEN BETR

TUB ROOM STORAGE

SPA / BATH

MENS BATH

KITCHEN OFFICE

COOLER FREEZER

SECURE ROOM

STAFF TOILET

DRY STORAGE

PATIENT SOILED CLEAN LINENLAUNDRY UTILITY

1

Boulder Associates, Inc. Architecture + Interior Design 1426 Pearl Street, Suite 300 Boulder , Colorado 80302 303.499.7795 www.boulderassociates.com

QUIET

SUN ROOM TTLBv.20150126 2/20/2018 10:29:20 AM

SUPPORTIVE EATING

KITCHEN PHYS. OFFICE

5

4

DINING

STUDY

CAN / CART WASH JAN.

LAB

WOMENS

CLEAN LINEN

DOUBLE PATIENT

LOCKER MEDS

DOUBLE PATIENT

SINGLE PATIENT ROOM

PRAIRIE ROOM

L

PHARM / LAB STORAGE

JAN.

IT

K

EXISTING FLOOR PLAN

SHEET NUMBER

EXSTG.

THIS LINE IS 1 INCH LONG WHEN PRINTED TO FULL SCALE

7 6.8

G

OFFICE

EXISTING PLAN FOR ERC


CEILING, WHERE OCCURS, SEE RCP FOR TYPE AND HEIGHT

CEILING, WHERE OCCURS, SEE RCP FOR TYPE AND HEIGHT SEE PLAN

METAL STUD, SEE PLAN FOR SIZE, SEE STUD GAUGE AND SPACING TABLE

SEE PLAN

SEE PLAN

1" GYP BD LINER PANEL

BASE OF WALL - SEE DETAIL 6 ON THIS SHEET

TWO (2) LAYERS OF 5/8" TYPE 'X' GYP BD.

BASE OF WALL - SEE DETAIL 6 ON THIS SHEET

STC: 39 WHEN 3-5/8" 20GA (19MIL) STUDS @ 16" O.C. ARE USED. SEE: http://bit.ly/2r6wT3g *NOTE: 16"O.C. STC RATING IS AN INTERPOLATION OF 24" O.C. STC RATINGS BASED ON VENEKLASEN ASSOCIATES, INC ANALYSIS. SEE: http://bit.ly/2rnGUWv COMPLY WITH ALL REQUIREMENTS OF UL ASSEMBLY U465: 1HR WALL

http://bit.ly/2kMfKZ3

COMPLY WITH ALL REQUIREMENTS OF UL ASSEMBLY U437: 2HR SHAFTWALL

http://bit.ly/ND2p1Y

METAL STUD, SEE PLAN FOR SIZE, SEE STUD GAUGE AND SPACING TABLE

CEILING, WHERE OCCURS, SEE RCP FOR TYPE AND HEIGHT

CEILING, WHERE OCCURS, SEE RCP FOR TYPE AND HEIGHT

CEILING, WHERE OCCURS, SEE RCP FOR TYPE AND HEIGHT SEE PLAN

5/8" TYPE 'X' GYP BD

SEE PLAN

5/8" TYPE 'X' GYP BD EACH SIDE.

METAL STUD, SEE PLAN FOR SIZE, SEE STUD GAUGE AND SPACING TABLE

5/8" TYPE 'X' GYP BD.

FULL WIDTH BATT INSULATION

FULL WIDTH BATT INSULATION

FULL WIDTH BATT INSULATION

BASE OF WALL - SEE DETAIL 6 ON THIS SHEET

BASE OF WALL - SEE DETAIL 6 ON THIS SHEET

1Sa - 1 HOUR SHAFTWALL COMPLY WITH ALL REQUIREMENTS OF UL ASSEMBLY U437: 1HR SHAFTWALL

STC: 39 WHEN 3-5/8" 20GA (19MIL) STUDS @ 16" O.C. ARE USED. SEE: http://bit.ly/2r6wT3g *NOTE: 16"O.C. STC RATING IS AN INTERPOLATION OF 24" O.C. STC RATINGS BASED ON VENEKLASEN ASSOCIATES, INC ANALYSIS. SEE: http://bit.ly/2rnGUWv COMPLY WITH ALL REQUIREMENTS OF UL ASSEMBLY U465: 1HR WALL

http://bit.ly/ND2p1Y

http://bit.ly/2kMfKZ3

KICKER - SEE DETAIL 5 ON THIS SHEET

RESILIENT CHANNELS, SCREWED TO STUDS HORIZONTALLY AT 24" OC

6"

CEILING, WHERE OCCURS, SEE RCP FOR TYPE AND HEIGHT

TWO (2) LAYERS OF 5/8" TYPE 'X' GYP BD ONE SIDE, ONE (1) LAYER ON OTHER SIDE

FULL WIDTH BATT INSULATION

FULL WIDTH BATT INSULATION

FULL WIDTH BATT INSULATION

SEE DETAIL 4 ON THIS SHEET FOR HEAD DETAIL

KICKER - SEE DETAIL 5 ON THIS SHEET

OMIT GYP BD ABOVE CEILING WHEN CEILING IS GYP BD IN THE ENTIRE ROOM

OMIT GYP BD ABOVE CEILING WHEN CEILING IS GYP BD IN THE ENTIRE ROOM

2' - 0". EACH SIDE OF WALL

BATT INSULATION, LAY OVER TOP OF WALL SEE PLAN

METAL STUD, SEE PLAN FOR SIZE, SEE STUD GAUGE AND SPACING TABLE

METAL STUD, SEE PLAN FOR SIZE, SEE STUD GAUGE AND SPACING TABLE

FULL WIDTH BATT INSULATION

BASE OF WALL - SEE DETAIL 6 ON THIS SHEET

FULL WIDTH BATT INSULATION

BASE OF WALL - SEE DETAIL 6 ON THIS SHEET

0Pa - PARTIAL HEIGHT PARTITION A

0Pb - PARTIAL HEIGHT SOUND PARTITION B

UNDERSIDE OF STRUCTURE SEE DETAIL 3 ON THIS SHEET

PROVIDE KICKERS AT 48" OC, OR INSTALL FURRED WALL TO STRUCTURE WITH SLIP TRACK, OR CLIP TO STRUCTURE BEHIND

6" SEE PLAN

CEILING, WHERE OCCURS, SEE RCP FOR TYPE AND HEIGHT

SEE PLAN

5/8" TYPE 'X' GYP BD EACH SIDE

METAL STUD, SEE PLAN FOR SIZE, SEE STUD GAUGE AND SPACING TABLE

METAL STUD, SEE PLAN FOR SIZE, SEE STUD GAUGE AND SPACING TABLE

FULL WIDTH BATT INSULATION

FULL WIDTH BATT INSULATION

BASE OF WALL - SEE DETAIL 6 ON THIS SHEET

PARTITION TYPES

A7.10

6" (TYP) @ OPENINGS

METAL STUD, SEE PLAN FOR SIZE, SEE STUD GAUGE AND SPACING TABLE

METAL STUD, SEE PLAN FOR SIZE, SEE STUD GAUGE AND SPACING TABLE

FULL WIDTH BATT INSULATION

FULL WIDTH BATT INSULATION BASE OF WALL - SEE DETAIL 6 ON THIS SHEET

0Ad - FULL HEIGHT SOUND PARTITION D

0Ae - FULL HEIGHT SOUND PARTITION E

STC: 42 WHEN 3-5/8" 20GA (19MIL) STUDS @ 16" O.C. ARE USED. SEE: http://bit.ly/2qXAz71 *NOTE: 16"O.C. STC RATING IS AN INTERPOLATION OF 24" O.C. STC RATINGS BASED ON VENEKLASEN ASSOCIATES, INC ANALYSIS. SEE:

STC: 39 WHEN 3-5/8" 20GA (19MIL) STUDS @ 16" O.C. ARE USED. SEE: http://bit.ly/2r6wT3g *NOTE: STC: 50 WHEN 3-5/8" 20 GA (19MIL) STUDS @ 16" O.C. ARE USED PER SOUND TEST RAL-TL12-197.

CEILING, WHERE OCCURS, SEE RCP FOR TYPE AND HEIGHT

STC: 43 WHEN 3-5/8" 20GA (19MIL) STUDS @ 16" O.C. ARE USED. SEE: http://bit.ly/2qphw5s *NOTE: 16"O.C. STC RATING IS AN INTERPOLATION OF 24" O.C. STC RATINGS BASED ON VENEKLASEN ASSOCIATES, INC ANALYSIS. SEE: http://bit.ly/2rnGUWv COMPLY WITH ALL REQUIREMENTS OF UL ASSEMBLY U411: 2HR WALL

1/2" = 1'-0"

20 GA 3-5/8" METAL STUD KICKER AT 48" OC MAX. ALTERNATE DIRECTION MAX 12FT LONG STUD. PROVIDE A KICKER WITHIN 12" OF EACH JAMB STUD AT OPENINGS.

A7.10

3" = 1'-0"

ADDITIONAL LAYERS OF GYP BD WHERE OCCURS

STC: 39 WHEN 3-5/8" 20GA (19MIL) STUDS @ 16" O.C. ARE USED. SEE: http://bit.ly/2r6wT3g *NOTE: STC: 50 WHEN 3-5/8" 20 GA (19MIL) STUDS @ 16" O.C. ARE USED PER SOUND TEST RAL-TL12-197.

12"

6"

FASTEN STUDS TO TRACK WITH ONE SMS AT EACH SIDE OF EACH STUD SECURE TRACK TO FLOOR PER TRACK ATTACHMENT SCHEDULE ON THIS SHEET

CONCRETE FLOOR

FULL HEIGHT PARTITIONS SHOWN. SEE DETAILS 3 & 4 ON THIS SHEET FOR KICKER DETAILS AT PARTIAL HEIGHT PARTITIONS

TRACK

SEE SHEET A8.10 FOR HEADER CONSTRUCTION

METAL DECK

SEE DOOR DETAILS ON THE A8.X SERIES SHEETS FOR JAMB STUD CONSTRUCTION

SECURE TRACK TO DECK PER TRACK ATTACHMENT SCHEDULE ON THIS SHEET MINERAL WOOL PACKED IN METAL DECK FLUTES FULL WIDTH

SEE DOOR DETAILS ON THE A8.X SERIES SHEETS FOR JAMB STUD CONSTRUCTION

J-RUNNER TOP TRACK

FASTEN STUD TO TRACK WITH ONE SMS AT EACH SIDE OF EACH STUD

TRACK

FLOOR LINE 12"

6"

CONDITION WHERE PARTITION RUNS PARALLEL TO DECK

6"

GAP BETWEEN TOP OF STUD AND TRACK. SEE SLIP TRACK SCHEDULE FOR SIZE STOP GYP BD SHORT OF DECK. SEE SLIP TRACK SCHEDULE FOR GAP SIZE

SPRAY SEALANT HEAD JOINT. USE WHITE SMOKE/ACOUSTIC SPRAY AT NON-RATED PARTITIONS. USE RED FIRE SPRAY AT RATED PARTITIONS

http://bit.ly/2lI7DKC

SHAFTWALL HEAD DETAILS

A7.10

METAL DECK

20 GA X 4" WIDE MTL STRAP (OMIT STRAP WHERE WALL ALIGNS WITH LOWER FLUTE) SECURE TRACK TO STRAP PER TRACK ATTACHMENT SCHEDULE ON THIS SHEET J-RUNNER TOP TRACK

FASTEN STUD TO TRACK WITH ONE SMS AT EACH SIDE OF EACH STUD

ADDITIONAL LAYER OF GYP BD WHERE OCCURS

SPRAY CONDITION WHERE SHAFT WALL RUNS PERPENDICULAR TO DECK

7

CONCRETE ABOVE METAL DECK WHERE OCCURS

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

INTERIOR STUD GAUGE AND SPACING TABLE

BASE OF WALL DETAIL

*GAUGE MAY CHANGE AT GRAB BARS, LEAD LINED WALLS, ABUSE RESISTANT GYP BD, HANDRAILS, TILE, CASEWORK, DOORS, WINDOWS, ETC. SEE THE GENERAL NOTES ABOVE AND SHEET A7.11 FOR DETAILS. CONFIRM SYSTEM COMPLIES WITH CODE REQUIRED DEFLECTION CRITERIA. SEE SPECIFICATIONS FOR DETAILS.

TRACK ATTACHMENT SCHEDULE

3" = 1'-0"

TRACK ATTACHED TO:

MINERAL WOOL PACKED IN METAL DECK FLUTES FULL WIDTH

STOP GYP BD SHORT OF DECK. SEE SLIP TRACK SCHEDULE FOR GAP SIZE

SPRAY SEALANT HEAD JOINT. USE WHITE SMOKE/ACOUSTIC SPRAY AT NON-RATED PARTITIONS. USE RED FIRE SPRAY AT RATED PARTITIONS

FASTEN STUD TO TRACK WITH ONE SMS AT EACH SIDE OF EACH STUD

STOP GYP BD 1/2" ABOVE FLOOR. PROVIDE BACKER ROD & SEALANT. USE WHITE SMOKE/ACOUSTIC SEALANT AT NON-RATED PARTITIONS. USE RED FIRE SEALANT AT RATED PARTITIONS.

SECURE TRACK TO FLOOR PER TRACK ATTACHMENT SCHEDULE ON THIS SHEET

CONCRETE FLOOR

ADDITIONAL LAYER OF GYP BD WHERE OCCURS

BOTTOM OF SHAFT WALL DETAIL AT 1HR AND 2HR WALLS, COMPLY WITH ALL REQUIREMENTS OF UL ASSEMBLY BW-S-0023

AT 1HR AND 2HR SHAFTWALLS, COMPLY WITH ALL REQUIREMENTS OF UL ASSEMBLY HW-D-0539

http://bit.ly/2lJdQqL

3" = 1'-0"

http://bit.ly/2l1lGMo

8

SPACING

PROVIDE THE FOLLOWING STUD GAUGE AND SPACING AT ALL PARTITIONS UNO:

FASTENER

SPACING**

EXPANSION ANCHORS FASTENERS (PAF)

32"*

POWER ACTUATED EXPANSION ANCHORS

24"*

ADDITIONAL LAYERS OF GYP BD WHERE OCCURS

GAP BETWEEN TOP OF STUD AND TRACK. SEE SLIP TRACK SCHEDULE FOR SIZE

GAUGE

http://bit.ly/2lcYmyk

SECURE STRAP TO DECK PER TRACK ATTACHMENT SCHEDULE ON THIS SHEET

SPRAY CONDITION WHERE SHAFT WALL RUNS PARALLEL TO DECK

EDITOR'S NOTE: DELETE IF NO SHAFTWALLS IN PROJECT

EDITOR'S NOTE: CONFIRM A7.11 DETAILS REFERENCED IN THESE NOTES EXIST

1. 2.

CONCRETE OR METAL DECK WITH CONCRETE (COMPOSITE DECK)

CONCRETE ABOVE METAL DECK WHERE OCCURS

20 GA 3-5/8" METAL STUD KICKER AT 48" OC MAX. ALTERNATE DIRECTION MAX 9FT LONG STUD. PROVIDE A KICKER WITHIN 12" OF EACH JAMB STUD AT OPENINGS.

20GA/33MIL (OR EQUIVALENT) AT 16" O.C. IS OUR STANDARD; IT WILL SPAN A HEIGHT UP TO 16'-9". REVISE GUAGE OR SPACING AS NEEDED

6

6"

ATTACH KICKER TO DEEP LEG TRACK WITH (2) SMS EACH SIDE

EDITOR'S NOTE: DELETE ITEM 12 OR 13 DEPENDING ON YOUR CODE.

STOP GYP BD 1/2" ABOVE FLOOR. PROVIDE BACKER ROD & SEALANT. USE WHITE SMOKE/ACOUSTIC SEALANT AT NON-RATED PARTITIONS. USE RED FIRE SEALANT AT RATED PARTITIONS.

BASE OF WALL - SEE DETAIL 6 ON THIS SHEET

16" LONG LIGHT GUAGE ANGLE

GENERAL NOTES

METAL STUD, SEE PLAN FOR SIZE, SEE STUD GAUGE AND SPACING TABLE

0Af - FULL HEIGHT SOUND PARTITION F

20 GA METAL STRAP SECURED TO BOTTOM OF AT LEAST TWO METAL DECK FLUTES.

.75 TO 1.25 MAX

EDITORS NOTE: IN CALIFORNIA AND OTHER HIGH SEISMIC LOCATIONS, CHANGE THE TOP TRACK FROM 20GA TO 18 GA.

5/8" TYPE 'X' GYP BD EACH SIDE

FULL WIDTH BATT INSULATION

1

ATTACH KICKER TO TOP TRACK WITH (4) SMS AT EACH KICKER 20 GA TOP TRACK FASTEN STUD TO TRACK WITH ONE SMS AT EACH SIDE OF EACH STUD GYP BD WHERE OCCURS

CONDITION WHERE PARTITION RUNS PERPENDICULAR TO DECK

AT 1HR AND 2HR WALLS, COMPLY WITH ALL REQUIREMENTS OF UL ASSEMBLY BW-S-0002

INTERIOR DOOR & WINDOW STUD WALL FRAMING ELEVATION

A7.10

ATTACH KICKER TO DEEP LEG TRACK WITH (2) SMS EACH SIDE

BOTTOM OF WALL DETAIL

AT 1HR AND 2HR SHAFTWALLS, COMPLY WITH ALL REQUIREMENTS OF UL ASSEMBLY HW-D-0569

2

16" LONG LIGHT GUAGE ANGLE

http://bit.ly/2kpGMCk

INDICATES TRACK ATTACHMENT TO THE DECK (TYP). SECURE TRACK TO DECK PER TRACK ATTACHMENT SCHEDULE ON THIS SHEET (TYP)

INDICATES TRACK ATTACHMENT TO THE FLOOR (TYP). AT OPENINGS UNDER 6FT WIDE, PROVIDE TWO PAF'S LOCATED 6" OFF THE JAMB. AT OPENINGS OVER 6FT, PROVIDE ONE EXPANSION ANCHOR LOCATED WITHIN 6" OF THE JAMB.

CUT FLANGES AND BEND WEB BACK

.75 TO 1.25 MAX

FASTEN STUD TO TRACK WITH ONE SMS AT EACH SIDE OF EACH STUD

KICKER DETAILS

SECURE LIGHT GAUGE ANGLE TO DECK WITH TWO FASTENERS PER TRACK ATTACHMENT SCHEDULE ON THIS SHEET. CENTER FASTENTERS IN THE DECK VALLEY

CONCRETE ABOVE METAL DECK WHERE OCCURS

METAL DECK

1

SEE PLAN

6" (TYP) @ OPENINGS

CONDITION WHERE PARTITION RUNS PARALLEL TO DECK (NO GYP BD)

SECURE LIGHT GAUGE ANGLE TO DEKC WITH TWO FASTENERS PER TRACK ATTACHMENT SCHEDULE ON THIS SHEET. CENTER FASTENTERS IN THE DECK VALLEY

GYP BD WHERE OCCURS

5

SLIP TRACK. SEE SLIP TRACK SCHEDULE ON THIS SHEET FOR DETAILS

FASTEN STUD TO TRACK WITH ONE SMS AT EACH SIDE OF EACH STUD

3" = 1'-0"

ATTACH KICKER TO TOP TRACK WITH (4) SMS AT EACH KICKER

A7.10

INDICATES (S) SIMPSON L30 CLIP W/ (4) SMS TYP

SLIP TRACK. SEE SLIP TRACK SCHEDULE ON THIS SHEET FOR DETAILS

CUT FLANGES AND BEND WEB BACK

UNDERSIDE OF STRUCTURE SEE DETAIL 3 ON THIS SHEET

GAP BETWEEN TOP OF STUD AND TRACK. SEE SLIP TRACK SCHEDULE FOR SIZE

SECURE TRACK TO STRAP PER TRACK ATTACHMENT SCHEDULE ON THIS SHEET

METAL DECK

FULL WIDTH BATT INSULATION BASE OF WALL - SEE DETAIL 6 ON THIS SHEET

METAL DECK

20 GA X 4" WIDE MTL STRAP (OMIT STRAP WHERE WALL ALIGNS WITH LOWER FLUTE)

GAP BETWEEN TOP OF STUD AND TRACK. SEE SLIP TRACK SCHEDULE FOR SIZE

CONCRETE ABOVE METAL DECK WHERE OCCURS

SEE GENERAL NOTES ON THIS SHEET FOR FURTHER REQUIREMENTS

1 1/2" = 1'-0"

6" (TYP) @ OPENINGS

TWO (2) LAYERS OF 5/8" TYPE 'X' GYP BD BOTH SIDES

BASE OF WALL - SEE DETAIL 6 ON THIS SHEET

BASE OF WALL - SEE DETAIL 6 ON THIS SHEET

0Ac - FULL HEIGHT SOUND PARTITION C

EDITOR'S NOTE: DELETE UNUSED PARTITIONS

SEE PLAN

TWO (2) LAYERS OF 5/8" TYPE 'X' GYP BD ONE SIDE, ONE (1) LAYER ON OTHER SIDE

CONCRETE ABOVE METAL DECK WHERE OCCURS

SECURE STRAP TO DECK PER TRACK ATTACHMENT SCHEDULE ON THIS SHEET

HEAD OF PARTITION DETAILS - NO GYPSUM BOARD

A7.10

CEILING, WHERE OCCURS, SEE RCP FOR TYPE AND HEIGHT

0Fa - FURRING PARTITION

CEILING, WHERE OCCURS, SEE RCP FOR TYPE AND HEIGHT

CEILING, WHERE OCCURS, SEE RCP FOR TYPE AND HEIGHT

SEE PLAN

5/8" TYPE 'X' GYP BD EACH SIDE

0Ab - FULL HEIGHT SOUND PARTITION B

1

CONCRETE ABOVE METAL DECK WHERE OCCURS

CONDITION WHERE PARTITION RUNS PERPENDICULAR TO DECK (NO GYP BD)

4

RESILIENT CHANNELS, SCREWED TO STUDS HORIZONTALLY AT 24" OC

CEILING, WHERE OCCURS, SEE RCP FOR TYPE AND HEIGHT

http://bit.ly/2lI4BpY

3" = 1'-0"

METAL STUD, SEE PLAN FOR SIZE, SEE STUD GAUGE AND SPACING TABLE

OMIT GYP BD ABOVE CEILING WHEN CEILING IS GYP BD IN THE ENTIRE ROOM

SLIP TRACK. SEE SLIP TRACK SCHEDULE ON THIS SHEET FOR DETAILS

ADDITIONAL LAYER OF GYP BD WHERE OCCURS

HEAD OF PARTITION DETAILS

FASTEN STUD TO TRACK WITH ONE SMS AT EACH SIDE OF EACH STUD

5/8" TYPE 'X' GYP BD

UNDERSIDE OF STRUCTURE SEE DETAIL 3 ON THIS SHEET

STOP GYP BD SHORT OF DECK. SEE SLIP TRACK SCHEDULE FOR GAP SIZE

FASTEN STUD TO TRACK WITH ONE SMS AT EACH SIDE OF EACH STUD

AT 1HR AND 2HR WALLS, COMPLY WITH ALL THE REQUIREMENTS OF UL ASSEMBLY HW-D-0042

20 GA TOP TRACK UNDERSIDE OF STRUCTURE SEE DETAIL 3 ON THIS SHEET

SPRAY SEALANT HEAD JOINT. USE WHITE SMOKE/ACOUSTIC SPRAY AT NON-RATED PARTITIONS. USE RED FIRE SPRAY AT RATED PARTITIONS

SPRAY CONDITION WHERE PARTITION RUNS PARALLEL TO DECK

SECURE TRACK TO DECK PER TRACK ATTACHMENT SCHEDULE ON THIS SHEET

STC: 42 WHEN 3-5/8" 20GA (19MIL) STUDS @ 16" O.C. ARE USED. SEE: http://bit.ly/2qXAz71 *NOTE: STC: 50 WHEN 3-5/8" 20 GA (19MIL) STUDS @ 16" O.C. ARE USED PER SOUND TEST RAL-TL12-197.

UNDERSIDE OF STRUCTURE SEE DETAIL 3 ON THIS SHEET

GAP BETWEEN TOP OF STUD AND TRACK. SEE SLIP TRACK SCHEDULE FOR SIZE

SECURE TRACK TO STRAP PER TRACK ATTACHMENT SCHEDULE ON THIS SHEET

METAL DECK

STRUCTURE

1/2" GAP

CONCRETE ABOVE METAL DECK WHERE OCCURS

20 GA X 4" WIDE MTL STRAP (OMIT STRAP WHERE WALL ALIGNS WITH LOWER FLUTE)

AT 1HR AND 2HR WALLS, COMPLY WITH ALL THE REQUIREMENTS OF UL ASSEMBLY HW-D-0042

UNDERSIDE OF STRUCTURE SEE DETAIL 3 ON THIS SHEET

BASE OF WALL - SEE DETAIL 6 ON THIS SHEET

0Pd - PARTIAL HEIGHT SOUND PARTITION D

MINERAL WOOL PACKED IN METAL DECK FLUTES FULL WIDTH

SPRAY CONDITION WHERE PARTITION RUNS PERPENDICULAR TO DECK

A7.10

KICKER - SEE DETAIL 5 ON THIS SHEET

SEE PLAN

EDITOR'S NOTE: THESE SCRIBE DETAILS ONLY WORK FOR DEFLECTION OF 3/4" OR LESS AT RATED WALLS

METAL DECK

SLIP TRACK. SEE SLIP TRACK SCHEDULE ON THIS SHEET FOR DETAILS

STC: 39 WHEN 3-5/8" 20GA (19MIL) STUDS @ 16" O.C. ARE USED. SEE: http://bit.ly/2r6wT3g *NOTE: 16"O.C. STC RATING IS AN INTERPOLATION OF 24" O.C. STC RATINGS BASED ON VENEKLASEN ASSOCIATES, INC ANALYSIS. SEE: http://bit.ly/2rnGUWv COMPLY WITH ALL REQUIREMENTS OF UL ASSEMBLY U465: 1HR WALL

SEE DETAIL 4 ON THIS SHEET FOR HEAD DETAIL

FASTEN STUD TO TRACK WITH ONE SMS AT EACH SIDE OF EACH STUD

SECURE STRAP TO DECK PER TRACK ATTACHMENT SCHEDULE ON THIS SHEET

http://bit.ly/2lI4BpY

3

SLIP TRACK. SEE SLIP TRACK SCHEDULE ON THIS SHEET FOR DETAILS

CONTRACTOR'S OPTION: USE HEAD DETAIL ABOVE OR BELOW.

STOP GYP BD SHORT OF DECK. SEE SLIP TRACK SCHEDULE FOR GAP SIZE

ADDITIONAL LAYER OF GYP BD WHERE OCCURS

http://bit.ly/2kMfKZ3

TWO (2) LAYERS OF 5/8" TYPE 'X' GYP BD ONE SIDE, ONE (1) LAYER ON OTHER SIDE

5/8" TYPE 'X' GYP BD EACH SIDE

ADDITIONAL LAYER OF GYP BD WHERE OCCURS

SPRAY SEALANT HEAD JOINT. USE WHITE SMOKE/ACOUSTIC SPRAY AT NON-RATED PARTITIONS. USE RED FIRE SPRAY AT RATED PARTITIONS

FASTEN STUD TO TRACK WITH ONE SMS AT EACH SIDE OF EACH STUD

BASE OF WALL - SEE DETAIL 6 ON THIS SHEET

CEILING, WHERE OCCURS, SEE RCP FOR TYPE AND HEIGHT

SEE PLAN

CEILING, WHERE OCCURS, SEE RCP FOR TYPE AND HEIGHT

FASTEN STUD TO TRACK WITH ONE SMS AT EACH SIDE OF EACH STUD

GAP BETWEEN TOP OF STUD AND TRACK. SEE SLIP TRACK SCHEDULE FOR SIZE

SECURE TRACK TO DECK PER TRACK ATTACHEMENT SCHEDULE ON THIS SHEET

1Ac - 1 HOUR FIRE PARTITION

OMIT GYP BD ABOVE CEILING WHEN CEILING IS GYP BD IN THE ENTIRE ROOM

FULL WIDTH BATT INSULATION

BASE OF WALL - SEE DETAIL 6 ON THIS SHEET

5/8" TYPE 'X' GYP BD EACH SIDE.

CONTRACTOR'S OPTIONINSTALL STUDS TO STRUCTURE WITH SLIP TRACK PER DETAIL 2 ON THIS SHEET

METAL STUD, SEE PLAN FOR SIZE, SEE STUD GAUGE AND SPACING TABLE

0Ag - FULL HEIGHT SOUND PARTITION G

5/8" TYPE 'X' GYP BD EACH SIDE.

CONTRACTOR'S OPTIONINSTALL STUDS TO STRUCTURE WITH SLIP TRACK PER DETAIL 2 ON THIS SHEET

5/8" TYPE 'X' GYP BD EACH SIDE

METAL STUD, SEE PLAN FOR SIZE, SEE STUD GAUGE AND SPACING TABLE

CEILING, WHERE OCCURS, SEE RCP FOR TYPE AND HEIGHT

CONTRACTOR'S OPTIONINSTALL STUDS TO STRUCTURE WITH SLIP TRACK PER DETAIL 2 ON THIS SHEET

CEILING, WHERE OCCURS, SEE RCP FOR TYPE AND HEIGHT

SEE PLAN

KICKER - SEE DETAIL 5 ON THIS SHEET

SEE DETAIL 4 ON THIS SHEET FOR HEAD DETAIL

6"

UNDERSIDE OF STRUCTURE SEE DETAIL 3 ON THIS SHEET

CEILING, WHERE OCCURS, SEE RCP FOR TYPE AND HEIGHT

STC: 39 WHEN 3-5/8" 20GA (19MIL) STUDS @ 16" O.C. ARE USED. SEE: http://bit.ly/2r6wT3g *NOTE: 16"O.C. STC RATING IS AN INTERPOLATION OF 24" O.C. STC RATINGS BASED ON VENEKLASEN ASSOCIATES, INC ANALYSIS. SEE: http://bit.ly/2rnGUWv COMPLY WITH ALL REQUIREMENTS OF UL ASSEMBLY U465: 1HR WALL

SECURE TRACK TO STRAP PER TRACK ATTACHMENT SCHEDULE ON THIS SHEET

EDITOR'S NOTE: THESE SCRIBE DETAILS ONLY WORK FOR DEFLECTION OF 3/4" OR LESS AT RATED WALLS

METAL DECK

UNDERSIDE OF STRUCTURE SEE DETAIL 3 ON THIS SHEET FOR FIRE RATED HEAD DETAIL

METAL STUD, SEE PLAN FOR SIZE, SEE STUD GAUGE AND SPACING TABLE

http://bit.ly/2kMfKZ3

INSTALL BACKER ROD & SEALANT. USE WHITE SEALANT AT NONRATED PARTITIONS. USE RED SEALANT AT RATED PARTITIONS

SLIP TRACK. SEE SLIP TRACK SCHEDULE ON THIS SHEET FOR DETAILS

CONCRETE ABOVE METAL DECK WHERE OCCURS

METAL STUD, SEE PLAN FOR SIZE, SEE STUD GAUGE AND SPACING TABLE

1Aa - 1 HOUR FIRE BARRIER

SCRIBE (CASTLE CUT) GYP BD TO MATCH PROFILE OF METAL DECK. SEE SLIP TRACK SCHEDULE FOR GAP SIZE

MINERAL WOOL PACKED IN METAL DECK FLUTES FULL WIDTH

BASE OF WALL - SEE DETAIL 6 ON THIS SHEET

BASE OF WALL - SEE DETAIL 8 ON THIS SHEET

1Ab - 1 HOUR SMOKE BARRIER

SEE DETAIL 4 ON THIS SHEET FOR HEAD DETAIL

CONTRACTOR'S OPTION: USE HEAD DETAIL ABOVE OR BELOW.

SEE PLAN

SEE PLAN

1" GYP BD LINER PANEL

GAP BETWEEN TOP OF STUD AND TRACK. SEE SLIP TRACK SCHEDULE FOR SIZE

INSTALL BACKER ROD & SEALANT. USE WHITE SEALANT AT NONRATED PARTITIONS. USE RED SEALANT AT RATED PARTITIONS

SCRIBE CONDITION WHERE PARTITION RUNS PARALLEL TO DECK

http://bit.ly/2lCUQgz

UNDERSIDE OF STRUCTURE - SEE DETAIL 3 ON THIS SHEET FOR FIRE RATED HEAD DETAIL

METAL C-H STUD, SEE PLAN FOR SIZE, SEE STUD GAUGE AND SPACING TABLE

20 GA X 4" WIDE MTL STRAP (OMIT STRAP WHERE WALL ALIGNS WITH LOWER FLUTE)

AT 1HR AND 2 HR WALLS, COMPLY WITH ALL REQUIREMENTS OF UL ASSEMBLY HW-D-0184 AT LOW FLUTE, HW-D-0264 AT HIGH FLUTE http://bit.ly/2lcRcJl OR http://bit.ly/2kMdaCu

STC: 43 WHEN 3-5/8" 20GA (19MIL) STUDS @ 16" O.C. ARE USED. SEE: http://bit.ly/2qphw5s *NOTE: 16"O.C. STC RATING IS AN INTERPOLATION OF 24" O.C. STC RATINGS BASED ON VENEKLASEN ASSOCIATES, INC ANALYSIS. SEE: http://bit.ly/2rnGUWv COMPLY WITH ALL REQUIREMENTS OF UL ASSEMBLY U411: 2HR WALL

UNDERSIDE OF STRUCTURE SEE DETAIL 7 ON THIS SHEET FOR FIRE RATED HEAD DETAIL

CONCRETE ABOVE METAL DECK WHERE OCCURS

GAP BETWEEN TOP OF STUD AND TRACK. SEE SLIP TRACK SCHEDULE FOR SIZE

AT 1HR AND 2HR WALLS, COMPLY WITH ALL REQUIREMENTS OF UL ASSEMBLY HW-D-0045

http://bit.ly/2kpGMCk

UNDERSIDE OF STRUCTURE SEE DETAIL 3 ON THIS SHEET FOR FIRE RATED HEAD DETAIL

5/8" GYP BD CROSS BRACES AT 1/3 POINTS. EACH BRACE TO BE 9-1/2" X 12" MIN. CONTRACTOR OPTION: USE 3'-5/8" 20GA STUD TRACK FOR CROSS BRACES.

0Ca - CHASE PARTITION

BASE OF WALL - SEE DETAIL 6 ON THIS SHEET

MINERAL WOOL PACKED IN METAL DECK FLUTES FULL WIDTH

METAL DECK

SCRIBE (CASTLE CUT) CONDITION WHERE PARTITION RUNS PERPENDICULAR TO DECK

2Aa - 2 HOUR FIRE BARRIER

http://bit.ly/2kpGMCk

UNDERSIDE OF STRUCTURE SEE DETAIL 3 ON THIS SHEET

SEE PLAN

FULL WIDTH BATT INSULATION

2Sa - 2 HOUR SHAFTWALL

STC: 43 WHEN 3-5/8" 20GA (19MIL) STUDS @ 16" O.C. ARE USED. SEE: http://bit.ly/2qphw5s *NOTE: 16"O.C. STC RATING IS AN INTERPOLATION OF 24" O.C. STC RATINGS BASED ON VENEKLASEN ASSOCIATES, INC ANALYSIS. SEE: http://bit.ly/2rnGUWv COMPLY WITH ALL REQUIREMENTS OF UL ASSEMBLY U411: 2HR WALL

SECURE TRACK TO DECK PER TRACK ATTACHMENT SCHEDULE ON THIS SHEET ADDITIONAL LAYER OF GYP BD WHERE OCCURS

BASE OF WALL - SEE DETAIL 8 ON THIS SHEET

2Ab - 2 HOUR SMOKE BARRIER

SCRIBE (CASTLE CUT) GYP BD TO MATCH PROFILE OF METAL DECK. SEE SLIP TRACK SCHEDULE FOR GAP SIZE

TWO (2) LAYERS OF 5/8" TYPE 'X' GYP BD EACH SIDE.

FULL WIDTH BATT INSULATION

0Aa - SMOKE PARTITION

METAL DECK

CEILING, WHERE OCCURS, SEE RCP FOR TYPE AND HEIGHT

FULL WIDTH BATT INSULATION

FULL WIDTH BATT INSULATION

SEE PLAN

CONCRETE ABOVE METAL DECK WHERE OCCURS

CEILING, WHERE OCCURS, SEE RCP FOR TYPE AND HEIGHT

TWO (2) LAYERS OF 5/8" TYPE 'X' GYP BD EACH SIDE.

SECURE STRAP TO DECK PER TRACK ATTACHMENT SCHEDULE ON THIS SHEET

MINERAL WOOL PACKED IN METAL DECK FLUTES FULL WIDTH

this is a 30" x 42" placeholder. After you insert this sheet into your project, swap it out for the standard titleblock

METAL STUD, SEE PLAN FOR SIZE, SEE STUD GAUGE AND SPACING TABLE

5/8" TYPE 'X' GYP BD EACH SIDE

UNDERSIDE OF STRUCTURE - SEE DETAIL 3 ON THIS SHEET FOR FIRE RATED HEAD DETAIL

METAL C-H STUD, SEE PLAN FOR SIZE, SEE STUD GAUGE AND SPACING TABLE

6"

SEE PLAN

UNDERSIDE OF STRUCTURE SEE DETAIL 7 ON THIS SHEET FOR FIRE RATED HEAD DETAIL

UNDERSIDE OF STRUCTURE - SEE DETAIL 3 ON THIS SHEET FOR FIRE RATED HEAD DETAIL

METAL STUD, SEE PLAN FOR SIZE, SEE STUD GAUGE AND SPACING TABLE

6"

UNDERSIDE OF STRUCTURE - SEE DETAIL 3 ON THIS SHEET

BASE OF SHAFTWALL DETAIL

A7.10

3" = 1'-0"

EDITOR'S NOTE: DELETE IF NO SHAFTWALLS IN PROJECT

STEEL STRAP, OR STUD OTHER

#10 SELF-DRILLING, SELFTAPPING SHEET METAL SCREW ATTACHMENT TO BE APPROVED BY THE ARCHITECT

16" 32"*

20 GA (33MIL) OR ENGINEERED EQUIVALENT*

16" OC

REMARKS USE 0.157" DIAMETER HILTI KB-TZ OR KB-VTZ WEDGE BOLT ANCHORS. INSTALL THE HILTI KB-TZ ANCHOR PER ICC ESR 1917 AND INSTALL THE KB-VTZ PER ICC ESR 3904. PROVIDE 18GA TRACK WHERE EXPANSION ANCHORS ARE USED. HILTI XP OR XU FASTENERS WITH 1" EMBEDMENT INSTALLED PER ICC ESR 2269. USE POWER ACTUATED FASTENERS (PAF'S) UNLESS EXPANSION ANCHORS ARE REQUIRED. USE EXPANSION ANCHORS WHERE SHEAR EXCEEDS 90LBS. PER ICC ESR 2269 AND AT THE FOLLOWING LOCATIONS: 1. WALL HUNG CABINETS OR SHELVING THAT EXTEND MORE THAN 15" FROM THE FACE OF THE WALL. DOES NOT APPLY TO BASE CABINETS SITTING ON THE FLOOR BUT ATTACHED TO THE WALL. 2. MONITORS WITH ARTICULATING ARMS. 3. AT STEEL CONCEALED BRACES. STEEL IS <= 18GA STEEL IS > 18GA

*OR AS REQUIRED BY THE UL ASSEMBLY ** SPACING ASSUMES NORMAL WEIGHT CONCRETE. VERIFY SPACING IF ANCHORING INTO LIGHT WEIGHT CONCRETE

SLIP TRACK SCHEDULE

EDITOR'S NOTE: NOTIFY YOUR STRUCTURAL ENGINEER IF YOU HAVE LIGHT WEIGHT CONCRETE. SPACING FOR EXPANSION ANCHORS AND/OR PAF'S MAY NEED TO CHANGE. EMBEDMENT DEPTH OF EXPANSION ANCHORS ALSO MAY CHANGE.

VERTICAL SLOT SLIP TRACK:* 2-1/2" CLARKDIETRICH MAXTRACK SLT**

3/4" (1-1/2" OF MOVEMENT: 3/4" UP, 3/4" DOWN)

3" CLARKDIETRICH MAXTRACK SLT**

1" (2" OF MOVEMENT: 1" UP, 1" DOWN)

REQUIRED DEFLECTION:

GAP BETWEEN TOP OF STUD AND TRACK:

GAP BETWEEN TOP OF GYP BD AND BOTTOM OF METAL DECK:

3/4"

3/4"

1"

1"

EDITOR'S NOTE: THIS SHEET HAS BEEN REVIEWED BY A STRUCTURAL ENGINEER IN CALIFORNIA. HOWEVER, IT IS GENERIC IN NATURE TO WORK IN ALL STATES. IF YOU HAVE A STRUCTURAL ENGINEER, EMAIL THIS PAGE TO THEM AND ASK THEM TO REVIEW. IF YOU SEE ANYTHING THAT SHOULD BE CHANGED, PLEASE CONTACT THE OPS TEAM.

OFFICE

DO NOT USE

PARTITION DETAILS

* OR SIMILAR PRODUCT BY OTHER MANUFACTURERS IF APPROVED BY ARCHITECT. CONTRACTOR'S OPTION: PROVIDE A DEEP LEG TRACK THAT ALLOWS THE DEFLECTION SHOWN ON THIS TABLE AND COMPLIES WITH THE UL DETAIL SHOWN. ** PLACE SCRES IN THE MIDDLE OF THE SLOT TO ALLOW UP AND DOWN MOVEMENT.

EDITOR'S NOTE: THE GAP SHOWN IN THIS SCHEDULE IS A FUNCTION OF BEAM SPACING/LENGTH, AND SOMETIMES SNOW LOAD, HEAVY FLOOR LIVE LOADS, AND SLAB ON GRADE MOVEMENT RELATED TO SOILS. REFER TO THE SOILS REPORT AND CONSULT WITH THE STRUCTURAL ENGINEER TO DETERMINE THE REQUIRED GAP SIZE. PICK 3/4" GAP, 1" TRACK OR BOTH. IF YOU KEEP BOTH CALL OUT WHERE TO USE EACH TRACK. IF YOU NEED MORE THAN 1" DEFLECTION, YOU NEED TO ORDER CUSTOM SLIP TRACK OR USE CLIPS. PER OUR STRUCTURAL ENGINEER: "3/4” gap should be a minimum and is not sufficient in most cases. 1” is much more common."

A7.10

C:\Revit Local Files\BA Details A17_rhouser.rvt

PARTITION DETAILS SHEET FOR FIRMWIDE DETAILS SET

12/12/2017 3:43:21 PM


2 1/2" LEG J-TRACK W/ POWDER DRIVEN FASTENERS @ 24" OC

LOW WALL (AKA PONY WALL)

MINERAL WOOL SAFING INSULATION

TRACK

2 1/2" E-STUDS, ATTACHED TO TOP RUNNER TRACK WITH 1/2" S-12 PAN HEAD, SELF DRILLING SCREWS

NOTES:

3-5/8" 20GA. METAL STUD KICKERS AT 48" O.C.

HORIZONTAL ASSEMBLY PER PROGRESSIVE ENGINEERING, INC. REPORT NUMBER AER-09038

OPENING TO BE OVERSIZED 1/2" MAX

RECESSED BOXES IN NON-RATED SOUND AND SMOKE PARTITIONS

A7.11

2

3" = 1'-0"

STUD WALL SECTION

DROP CEILING WHERE OCCURS, SEE REFLECTED CEILING PLANS FOR MATERIAL AND LOCATION

3

4

FIRE RATED OR SMOKE RATED WALL @ OBSTRUCTION

A7.11

3" = 1'-0"

6"

RECESSED ITEM, SEE PLANS

GYP BD AT HIGH PRIORITY WALL MUST CONTINUE PAST LOWER PRIORITY WALL

LOWER PRIORITY WALL

LP

HIGHER PRIORITY WALL

KING STUD WHERE CONTROL JOINT OCCURS AT DOOR

ONE HOUR RATED FIRE TEST: WHI-647-3024

STEEL STUDS (SEE PLANS FOR SIZE)

1/2"

1 HOUR FIRE RATED ASSEMBLY PER UL U513 http://bit.ly/2wQrEIE

7

LP

LP

LP

8

RATED RECESS DETAIL

A7.11

HIGHER PRIORITY WALL

SOUND PARTITION, RE: PLAN

1" = 1'-0"

NON-RATED

1.

PROVIDE CONTROL JOINTS AS SHOWN ON THE DRAWINGS AND IN LONG PARTITIONS AT 30'-0" INTERVALS. CONTRACTOR SHALL PROPOSE EXACT LOCATIONS FOR ARCHITECT'S APPROVAL. EXTEND FROM FLOOR TO CEILING OR FROM DOOR HEAD TO CEILING.

2.

IF WALL COVERING IS SCHEDULED FOR A WALL WITH A CONTROL JOINT, THE WALL COVERING SHALL BE NEATLY AND EVENLY RECESSED INTO, AND FOLLOW THE CONTOURS OF, THE CONTROL JOINT. IF A WALL IS SCHEDULED TO BE PAINTED, PAINT THE CONTROL JOINT TO MATCH THE WALL

9

EDITOR'S NOTE: USG RECOMMENDS A CJ EVERY 30FT OF WALL LENGTH. IT IS ALSO A GOOD IDEA TO ADD CJ'S AT HEADS OF LEAD LINED DOORS, OR OTHER LARGER DOORS SUBJECT TO IMPACT BY GURNEYS OR OTHER MOVING OBJECTS. SHOW CJ LOCATIONS ON THE FLOOR PLAN. DELETE 1 HR AND/OR 2HR DETAILS IF NOT APPLICABLE

KING STUD WHERE CONTROL JOINT OCCURS AT DOOR

CONTROL JOINTS (CJ) IN GYP BD PARTITIONS

A7.11

3" = 1'-0"

SEAL BOXES TIGHT TO GYP BD WITH FLEXIBLE, FIRE RATED SEALANT. MAXIMUM 1/8" JOINT BETWEEN BOX AND GYP BD

GYP BD AT HIGH PRIORITY WALL MUST CONTINUE PAST LOWER PRIORITY WALL LEAD BATTEN

GYP BD AT HIGH PRIORITY WALL MUST CONTINUE PAST LOWER PRIORITY WALL

MINERAL WOOL COMPRESSED TO FILL OPENING

EDITOR'S NOTE: THIS DETAIL IS NOT NECESSARY IF YOU HAVE THERMAL BATTS IN THE EXTERIOR WALL

SOUND PARTITION @ EXTERIOR WALL

A7.11

3" = 1'-0"

SEE FLOOR PLAN FOR METAL STUD WIDTH

5/8" TYPE 'X' GYP BD

ADD BATT INSULATION TO STUD CAVITIES DIRECTLY ADJACENT TO INTERSECTING SOUND PARTITION TO PREVENT SOUND FROM FLANKING AROUND PARTITION. INSULATION TO EXTEND AT LEAST 16" FROM THE CENTERLINE OF THE SOUND PARTITION ON EACH SIDE

EDITOR'S NOTE: DELETE THIS DETAIL IF YOU DON'T HAVE RATED WALLS. DELETE THE 2HR DETAIL IF YOU HAVE 1 HR BUT NO 2HR RATED WALLS.

LOWER PRIORITY WALL

GYP BD AT HIGH PRIORITY WALL MUST CONTINUE PAST LOWER PRIORITY WALL

2 HOUR FIRE RATED ASSEMBLY PER G.A. WP 1830 http://bit.ly/2tEfLV7

NOTE: PROVIDE RATED RECESS DETAIL AT ALL OPENINGS OVER 4"X4" LOCATED IN FIRE RATED PARTITIONS INCLUDING BUT NOT LIMITED TO ZONE VALVE BOXES, CABINET UNIT HEATERS, & LIGHT CONTROLS

KING STUD WHERE CONTROL JOINT OCCURS AT DOOR

NOTES:

5/8" TYPE "X'' GYP BD ON EACH SIDE. SEE PARTITION DETAIL FOR MORE INFORMATION

CONDITION #2

HIGHER PRIORITY WALL

#10 SELF-DRILLING, SELF-TAPPING SHEET METAL SCREWS @ 2'-0" OC MAX TO FASTEN TWO STRIPS OF 5/8" TYPE 'X' GYP BD TO STUD

TWO HOUR RATED FIRE TEST: WHI-651-0318.1

CONTROL JOINT - FULL HEIGHT ON BOTH SIDES OF WALL

EXTERIOR CLADDING VARIES

5/8" TYPE 'X' GYP BD LP

CONDITION #1

SEE FLOOR PLAN FOR METAL STUD WIDTH

#10 SELF-DRILLING, SELF-TAPPING SHEET METAL SCREWS @ 2'-0" OC MAX TO FASTEN TWO STRIPS OF 5/8" TYPE 'X' GYP BD TO STUD

2 1/4"

GYP BD AT HIGH PRIORITY WALL MUST CONTINUE PAST LOWER PRIORITY WALL

2 LAYERS 5/8" TYPE "X" GYP BD ON EACH SIDE. SEE PARTITION DETAIL FOR MORE INFORMATION

5/8"

SEE FLOOR PLAN FOR METAL STUD WIDTH

5/8" TYPE 'X' GYP BD

1/2" EXPANSION ANCHORS ON BOTH SIDES OF THE PLATE WITH MIN. 2" EMBEDMENT. USE HILTI KB-TZ INSTALLED PER ICC ESR 1917 OR APPROVED EQUAL

CONTROL JOINT - FULL HEIGHT ON BOTH SIDES OF WALL

1/2"

5/8" TYPE "X'' GYP BD ON EACH SIDE. SEE PARTITION DETAIL FOR MORE INFORMATION 5/8"

3"x3"x1/4" (HSS3x3x14) STEEL TUBE WELDED TO 3-1/2"x9"x3/8" STEEL PLATE

3" = 1'-0"

CONTROL JOINT - FULL HEIGHT ON BOTH SIDES OF WALL

1/2"

6" WIDE RIBS OF 5/8" TYPE 'X' GYP BD LAMINATED TOGETHER AT 24" OC MAX

EDITOR'S NOTE: REVISE THE HEIGHT OF THE WALL AS NEEDED. MAX WALL HEIGHT FOR THIS SUPPORT IS 60". DELETE OR REVISE THE WOOD TRIM DETAIL IF NEEDED. NOTE THIS IS NOT THE X-RAY SHIELD WALL SUPPORT DETAIL. THIS IS A SEPARATE DETAIL.

LOW WALL (AKA PONY WALL)

A7.11

3" = 1'-0"

1" GYP LINER PANEL

ROUTE CONDUIT ABOVE STEEL TUBE

5/8" TYP 'X' GYP BD OVER METAL STUDS. SEE PLAN FOR WIDTH OF METAL STUDS

3/16"

CENTER OF POST WITHIN WALL

PENETRATION AT SOUND AND SMOKE PARTITION

A7.11

BASE AS SCHEDULED

5/8" TYPE 'X' GYP BD

THIS DETAIL APPLIES TO RECESSED BOXES USED FOR FIRE ALARM DEVICES, ELECTRICAL SWITCHES, ELECTRICAL RECEPTACLES, COMMUNICATION DEVICES, SECURITY DEVICES, ETC.

1

1 1/4"

BATT INSULATION

1/2" MAX

EDITOR'S NOTE: SOMETIMES THE PUTTY PACKS ARE NOT GOOD ENOUGH TO PREVENT FLANKING SOUND IF THE BOXES ARE CLOSE TOGETHER. CONSULT AN ACOUSTIC ENGINEER IF YOU HAVE NOISY ROOMS AND BOXES THAT ARE CLOSE TOGETHER. TAKE A PASS THROUGH THE FLOOR PLANS AND LOOK FOR BOXES THAT ARE BACK-TO-BACK AND MAKE ADJUSTMENTS. FULL-SIZE BOXES WON'T FIT BACK-TO-BACK UNLESS YOU USE A SLIM BOX

1/2"x4-1/2" PAINTED HARDWOOD TRIM

ANCHOR STUDS TO TUBE WITH SHOT PINS AT 18" OC AND 6" MAX FROM END OF TUBE

1" SHAFTLINER

PROVIDE AND INSTALL PUTTY PACKS AT RECESSED BOXES THAT ARE NOT SEPARATED BY AT LEAST 24" TO PREVENT SOUND TRANSMISSION THROUGH THE WALL

3/4"x5" PAINTED HARDWOOD TRIM

END OF WALL

42"

PIPING, CONDUIT DUCT OR OTHER PENETRATION

ANCHOR BOTTOM TRACK WITHIN 6" OF STEEL BASE PLATE

6"

HEAD-OF-WALL ASSEMBLY @ FIRE RATED PARTITIONS PER UL SYSTEM: #HW-D-0572

1/2" MAX

ADDITIONAL LAYERS OF GYP BD WHERE OCCURS

RECESSED BOX

PROVIDE DOUBLE STUDS AT ENDS OF WALL (TYP)

1 1/2"

40-3/4"

SEAL JOINT AIRTIGHT ON BOTH SIDES WITH BACKER-ROD AND WHITE, NON-HARDENING, ACOUSTIC SEALANT, TYP.

3"

3"

SEAL BOXES TIGHT TO GYP BD

1.

OBSTRUCTION

HILTI CP 572 @ SOUND & SMOKE PARTITIONS. HILTI CFS-SP WB SPRAY FIRESTOPPING @ FIRE RATED PARTITIONS

3"

LEAD BATTEN - LEAD TO BE SAME THICKNESS AT GYP. BD. LEAD LINING

ADDITIONAL LAYERS OF GYP BD WHERE OCCURS

RECESSED BOX

LOWER PRIORITY WALL

LP

LEAD-LINED GYP BD TYP CONDITION #3

CONDITION #4

EXTEND RATED WALL (INCLUDING GYPSUM BOARD ON BOTH SIDES) TO BACK FACE OF EXTERIOR GYPSUM BOARD

OUTSIDE CORNER

RECESSED ITEM, SEE PLANS

2 LAYERS OF 5/8" TYPE 'X' GYP BD LAMINATED TOGETHER NOTES:

RATED INTERIOR WALL, SEE FLOOR PLANS

SEAL BOXES TIGHT TO GYP BD WITH FLEXIBLE, FIRE RATED SEALANT. MAXIMUM 1/8" JOINT BETWEEN BOX AND GYP BD

NOTES:

EXTERIOR CLADDING

EXTERIOR WALL

PROVIDE AND INSTALL PUTTY PACKS AT RECESSED BOXES THAT ARE NOT SEPARATED BY AT LEAST 24" TO PREVENT SOUND TRANSMISSION THROUGH THE WALL

INSIDE CORNER

1.

THIS DRAWING IS A GRAPHICAL REPRESENTATION ONLY. REFER TO THE "PARTITION TYPES NOTES" LEGEND FOR WALL PRIORITY AND PARTITION NAMING INFORMATION.

1.

IN ALL RATED FIRE BARRIERS AND/OR RATED SMOKE BARRIERS, THE SURFACE AREA OF THE INDIVIDUAL RECESSED BOXES SHALL NOT EXCEED 16 SQUARE INCHES PER VOLUME ONE OF THE UL FIRE RESISTANCE DIRECTORY. THE AGGREGATE SURFACE AREA OF ALL RECESSED BOXES SHALL NOT EXCEED 100 SQUARE INCHES PER 100 SQUARE FEET OF WALL SURFACE. RECESSED BOXES WHICH EXCEED EITHER OF THESE STANDARDS SHALL BE RECESSED AS SHOWN IN "RATED RECESS DETAIL" ON A7.11

2.

THIS DETAIL APPLIES TO RECESSED BOXES USED FOR FIRE ALARM DEVICES, ELECTRICAL SWITCHES, ELECTRICAL RECEPTACLES, COMMUNICATION DEVICES, SECURITY DEVICES, ETC.

3.

BOXES CANNOT BE RECESSED INTO A WALL OR BARRIER WITH A RATING GREATER THAN 2 HOURS

3/8" DIAMETER LEAD DISCS OVER EACH SMS

LEAD BATTEN

LEAD-LINED GYP BD - SEE PLANS FOR LOCATIONS & WEIGHT

EDITOR'S NOTE: DELETE THIS DETAIL IF YOU DON'T HAVE RATED WALLS

this is a 30" x 42" placeholder. After you insert this sheet into your project, swap it out for the standard titleblock

2"

STEEL SUPPORT AT 7'-0" OC AND AT ALL ENDS OF WALL 1 1/2"

CONDITION #5

10

11

INTERSECTION OF PRIORITY WALLS

A7.11

12

LEAD SHIELDING RECESS DETAIL

A7.11

1" = 1'-0"

3" = 1'-0"

13

LEAD SHIELDING PLAN DETAIL

A7.11

3" = 1'-0"

RECESSED BOXES IN RATED FIRE AND SMOKE BARRIERS

A7.11

3" = 1'-0"

5/8" TYPE 'X' GYP BD WINDOW COVERING ABOVE

SILL BELOW

WINDOW COVERING ABOVE

WINDOW COVERING ABOVE

5/8" TYPE 'X' GYP BD WINDOW COVERING ABOVE

EXTERIOR WINDOW SYSTEM

PACK SPACE WITH MINERAL WOOL INSULATION

5

A7.11

3" = 1'-0"

14

WALL/GLASS JOINT DETAIL

A7.11

3" = 1'-0"

MULL-IT-OVER, 60 STC WALL TRIM SYSTEM, 1/2" LIGHT GRAY GASKET. PROVIDE FIRE RATED SYSTEM AT RATED WALLS.

CORNER BEAD

EDITOR'S NOTE: TRY TO AVOID THIS DETAIL. TRY TO JOG THE WALL INSTEAD.

PACK VOID WITH MINERAL WOOL

EXTERIOR WINDOW SYSTEM

3/8" NEOPRENE BLOCK. ADHERE TO WINDOW GLAZING AND SEAL BOTH SIDES

3/8" NEOPRENE BLOCK. ADHERE TO WINDOW GLAZING AND SEAL BOTH SIDES

EXTERIOR WINDOW SYSTEM

CORNER BEAD

EXTERIOR WINDOW SYSTEM

WALL JOG @ MULLION JOINT DETAIL

FACE OF GYP. BD. ABOVE AND BELOW WINDOW

PACK SPACE WITH MINERAL WOOL

VARIES, SEE PLAN

3/8" NEOPRENE BLOCK. ADHERE TO WINDOW GLAZING AND SEAL BOTH SIDES

EDITOR'S NOTE: TRY TO AVOID THIS DETAIL. TRY TO JOG THE WALL INSTEAD.

EDGE OF SILL

BATT INSULATION

WINDOW COVERING ABOVE

EXTERIOR WINDOW SYSTEM

15

WALL/MULLION OFFSET

A7.11

3" = 1'-0"

EDITOR'S NOTE: TRY TO AVOID THIS DETAIL. TRY TO JOG THE WALL INSTEAD.

METAL STUDS

3/8"

8" MAX

3/8" NEOPRENE BLOCK ADHERE TO WINDOW MULLION, SEAL ON BOTH SIDES

3/8"

3/8"

BRAKE METAL TRIM, PAINT TO MATCH WALL

SILL BELOW

BATT INSULATION

BUILD GYP BD SILL, FLUSH WITH WINDOW SILL

BRAKE METAL TRIM, PAINT TO MATCH WALL

3/8"

PACK SPACE W/ MINERAL WOOL

5/8" TYPE 'X' GYP BD, EXTEND TO GLASS

5/8" TYPE 'X' GYP BD

BATT INSULATION

5" MIN

BATT INSULATION

6

EDITOR'S NOTE: TRY TO AVOID THIS DETAIL. TRY TO JOG THE WALL INSTEAD.

WALL/MULLION JOINT DETAIL

A7.11

3" = 1'-0"

16

EDITOR'S NOTE: TRY TO AVOID THIS DETAIL. TRY TO JOG THE WALL INSTEAD.

INTERIOR PARTITION TERMINATION @ MULLION

A7.11

3" = 1'-0"

OFFICE

DO NOT USE

PARTITION DETAILS

A7.11

C:\Revit Local Files\BA Details A17_rhouser.rvt

12/12/2017 3:43:22 PM

PARTITION DETAILS SHEET FOR FIRMWIDE DETAILS SET


IBC PROJECT DATA

UP

CONSTRUCTION TYPE:

II-A, FULLY SPRINKLERED

BUILDING OCCUPANCY:

I-1, ASSISTED LIVING

PROJECT NUMBER

173235.00

TENANT:

DRAWN BY

FIRE RATED CONSTRUCTION REQUIREMENTS PRIMARY STRUCTURAL FRAME X HR EXTERIOR BEARING WALLS X HR INTERIOR BEARING WALLS X HR EXTERIOR NON-BEARING WALLS X HR INTERIOR NON-BEARING WALLS X HR FLOOR CONSTRUCTION X HR ROOF CONSTRUCTION X HR

RH

OCCUPANCY SEPARATIONS X HR SEPARATION

DATE

10/18/2017

REVISIONS

REV

DESCRIPTION

DATE

NFPA 101 PROJECT DATA CONSTRUCTION TYPE

II (222)

APPLICABLE CHAPTERS CHAPTER XX FIRE RATED CONSTRUCTION REQUIREMENTS EXTERIOR BEARING WALLS X HR INTERIOR BEARING WALLS X HR COLUMNS X HR BEAMS, GIRDERS, TRUSSES, ARCHES X HR FLOOR/CEILING ASSEMBLIES X HR ROOF/CEILING ASSEMBLIES X HR INTERIOR NON-BEARING WALLS X HR EXTERIOR NON-BEARING WALLS X HR OCCUPANCY SEPARATIONS X HR SEPARATION

PARTITION LEGEND GRAPHIC

DESCRIPTION 2 HOUR FIRE BARRIER / SHAFTWALL 1 HOUR SMOKE BARRIER 1 HOUR FIRE BARRIER / SHAFTWALL SMOKE PARTITION

DOOR LEGEND GRAPHIC

DESCRIPTION 90 MINUTE DOOR 60 MINUTE DOOR 45 MINUTE DOOR 20 MINUTE DOOR

SYMBOLS FIRE EXTINGUISHER / FIRE EXTINGUISHER CABINET

FIRE RATED DOOR - 20 MIN.

MHO

EXIT LIGHT FIXTURE (ARROW INDICATES DIRECTION OF EXIT)

20

MAGNETIC HOLD OPEN

EXIT

ROUTE "X"

EXIT ACCESS WITH MAX TRAVEL DISTANCE COMMON PATH

UP

UP

ACCESSIBLE ROUTE

CORRIDOR

LIFE SAFETY PLAN GENERAL NOTES • •

UP

SEE THE COVER SHEET FOR CODE DATA & DEFERRED SUBMITTALS ALL EGRESS ROUTES ARE ACCESSIBLE EGRESS ROUTES

STAIR ELEVATORS

ELEC. BATHING

ELECTRIC SOIL

EGRESS - EXIT ACCESS PATH

MECHANICAL

PATH TOILET

PATH A PATH B

TOILET

Boulder Associates, Inc. Architecture + Interior Design 1426 Pearl Street, Suite 300 Boulder , Colorado 80302 303.499.7795 www.boulderassociates.com

LENGTH 90' - 0" 173' - 8"

EGRESS - COMMON PATH PAT. ROOM 1 (ISO)

PAT. ROOM 3 TOILET

TOILET

TOILET

PROJECT

PAT. ROOM 5

PORTER PLACE SNF REHAB RENOVATION

PAT. ROOM 6 CORRIDOR

PATH B

PAT. ROOM 8

ADDRESS

C:\Revit Local Files\173235.00-A17 Central_rhouser.rvt

TOILET

A3.10

1

LENGTH

PAT. ROOM 4

TOILET

PAT. ROOM 7

PATH

PAT. ROOM 2

KEYPLAN

1001 EAST YALE AVE., DENVER, CO 80210

AMBULANCE VESTIBULE

2

RENOVATION SCOPE

A3.10

NO WORK REQUIRED (FOR REFERENCE ONLY)

STAFF WORK

NOT IN SCOPE

SCHEMATIC DESIGN

CLEAN WORK/ HOLD ?

STAFF TOILET

STORAGE

PAT. ROOM 10

LIFE SAFETY PLAN OF PORTER PLACE

PAT. ROOM 11 (ISO)

PAT. ROOM 12 TOILET

TOILET

STAIR

EXIT

UP

SHEET TITLE

AREA A

TOILET

1

G2.10

FLOOR 1 - LIFE SAFETY PLAN 3/32" = 1'-0"

FIRST FLOOR LIFE SAFETY PLAN

AREA B

PROJECT TRUE NORTH NORTH

PROJECT TRUE NORTH NORTH

SHEET NUMBER

G2.10

THIS LINE IS 1 INCH LONG WHEN PRINTED TO FULL SCALE

TTLBv.20150126

11/30/2017 2:55:42 PM

PAT. ROOM 9


WALL TYPES LEGEND

PROJECT NUMBER

DEMO PARTITION (E) PARTITION

AREA NOT IN PROJECT SCOPE

173235.00 DRAWN BY

AW DATE

DEMO SYMBOLS

K

M

N O

P 14. 2.

UP 3. 4.

5.

V 6.

7. 8.

X Y

9.

Z 10.

21.

8. BB

DEMO EXISTING WALL

2

DEMO EXISTING DOOR

3

DEMO EXISTING PLUMBING FIXTURE

4

DEMO EXISTING CEILING

5

DEMO EXISTING CASEWORK

6

DEMO EXISTING FLOORING

7

DEMO EXISTING ELECTRICAL OUTLET

REVISIONS

REV

DESCRIPTION

DATE

DEMO NOTES 1.

W

10/18/2017

1

10.

6

CONTRACTOR SHALL VISIT THE SITE AND UNDERSTAND THE EXTENT OF THE REMODEL AND ADDITION WORK REQUIRED PRIOR TO DEMOLITION. NOT ALL EXISTING CONDITIONS HAVE BEEN DOCUMENTED IN THEIR ENTIRETY AND NEW WORK WILL NEED TO BE COORDINATED ACCORDINGLY. IF/WHERE AREAS ARE SHADED AS 'EXISTING TO REMAIN', THEY ARE FOR VISUAL CLARIFICATION ONLY AND ARE NOT TRUE IDENTIFIERS OF THE PHYSICAL BOUNDARY OF THE SCOPE OF WORK. IT IS ANTICIPATED THAT THE CONTRACTOR WILL BE WORKING ABOVE, BELOW, AND OUTSIDE OF THIS REFERENCE AS NEEDED AND IS RESPONSIBLE FOR UNDERSTANDING THE TRUE EXTENTS OF THE SCOPE OF WORK TO SATISFY THE CONSTRUCTION OF THE NEW WORK COMPLETELY. DEMOLITION WORK SHALL BE EXECUTED IN CONFORMANCE WITH ALL CODES AND ORDINANCES AS SET FORTH BY ALL AUTHORITIES HAVING JURISDICTION. CONTRACTOR SHALL PROTECT EXISTING PLUMBING PIPING, INSULATION, AND ELECTRICAL CONDUIT TO REMAIN. SAWCUT WALLS TO BE DEMOLISHED WHERE THEY CONNECT TO WALLS THAT REMAIN, TYPICAL. PATCH AND REPAIR WALLS ADJOINING AND AFFECTED BY DEMOLITION TO ALLOW FOR A SEAMLESS TIE-IN. EXISTING BUILDING STRUCTURE TO REMAIN, UNO. REFER TO STRUCTURAL DRAWINGS. THE CONTRACTOR SHALL BRACE ALL EXISTING STRUCTURES AND ALL STRUCTURAL ELEMENTS AS NECESSARY DURING DEMOLITION. THE CONTRACTOR SHALL NOT CUT ANY STRUCTURAL WORK WITHOUT NOTIFYING THE ARCHITECT PRIOR TO EXECUTION SO THAT APPROVAL CAN BE OBTAINED FROM THE ARCHITECT AND STRUCTURAL ENGINEER. EXISTING WALLS, WINDOWS, AND DOORS TO REMAIN EXCEPT WHERE INDICATED ON DRAWINGS. SALVAGE THE FOLLOWING AT DISCRETION OF THE OWNER AND/OR PROPERTY MANAGER: ALL DOORS AND DOOR HARDWARE; LIGHT FIXTURES; MECHANICAL DIFFUSERS; WINDOW TREATMENTS; AND MILLWORK. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO CHECK THE ARCHITECTURAL DRAWINGS BEFORE PROCEEDING WITH THE INSTALLATIONS OF ANY MECHANICAL, PLUMBING, OR ELECTRICAL WORK. CONTRACTOR NEEDS TO COORDINATE WITH TRADES AND ANY DISCREPANCIES BETWEEN DESIGN ELEMENTS FOR SCOPE OF WORK NEED TO BE REPORTED TO THE ARCHITECT. FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS; REPORT ANY DISCREPANCIES TO THE ARCHITECT BEFORE CONTINUING.

CC

Boulder Associates, Inc. Architecture + Interior Design 1426 Pearl Street, Suite 300 Boulder , Colorado 80302 303.499.7795 www.boulderassociates.com

DD

FF

GG

HH

PROJECT

PORTER PLACE SNF REHAB RENOVATION

KEYPLAN

II

ADDRESS

1001 EAST YALE AVE., DENVER, CO 80210 C:\Revit Local Files\173235.00-A17 Central_rhouser.rvt

RENOVATION SCOPE

NO WORK REQUIRED (FOR REFERENCE ONLY)

JJ

NOT IN SCOPE

SCHEMATIC DESIGN

KK AREA A

1 2 3 4 5 6 7

TTLBv.20150126

11/30/2017 2:55:40 PM

LL 19.

17

16. 15.

13.

12.

11.5

11.

1

SHEET TITLE

DEMO PLANS

AREA B

FLOOR 1 - DEMO PLAN

AD2.10

1/8" = 1'-0"

PROJECT TRUE NORTH NORTH

2

FLOOR 1 - DEMO REFLECTED CEILING PLAN

AD2.10

1/8" = 1'-0"

PROJECT TRUE NORTH NORTH

PROJECT TRUE NORTH NORTH SHEET NUMBER

AD2.10

THIS LINE IS 1 INCH LONG WHEN PRINTED TO FULL SCALE

UP

DEMO PLAN OF PORTER PLACE


PROJECT NUMBER

MEETING T.

OFFICE

EP

OFFICE

RESIDENT TOILET 77 SF

173235.00

FITNESS

DRAWN BY

AW

SPA

DATE

10/18/2017

P

REVISIONS

REV

DESCRIPTION

DATE

CORRIDOR 740 SF UP

STAIR STAIR 180 SF

ST.

ELEC. 36 SF

TV LOUNGE V

BATHING BATHING 207 SF

ELEVATORS 166 SF

ELEC.

HALLWAY 40 SF

MECH.

ELECTRIC 129 SF

MECH.

SOIL

MECHANICAL 141 SF

SOIL 55 SF

W

FIRE PUMP

EP

TOILET 51 SF c. closet/wardrabe accessible from wheelchair d. bed, lounge chair, dresser, nightstand, side chair - accessible from a wheelchair

Y

8. 4' - 0"

STUDIO

Z

STUDIO

PAT. ROOM 2 227 SF

4' - 0"

PAT. ROOM 1 (ISO) 216 SF

2) every bed has sufficient space for stretcher without moving furniture

22.

X

10.

21. PAT. ROOM 3 196 SF

STUDIO

4' - 0"

STUDIO

BB

PAT. ROOM 4 208 SF

CORRIDOR 988 SF

TOILET 52 SF

Boulder Associates, Inc. Architecture + Interior Design 1426 Pearl Street, Suite 300 Boulder , Colorado 80302 303.499.7795 www.boulderassociates.com

TOILET 42 SF

EP

EP

EP

EP

CC

TOILET 42 SF

TOILET 46 SF

STUDIO

STUDIO

PAT. ROOM 5 228 SF

PAT. ROOM 6 231 SF

PROJECT

PORTER PLACE SNF REHAB RENOVATION

DD PAT. ROOM 8 215 SF

PAT. ROOM 7 233 SF

ADDRESS

PAT. ROOM 7 233 SF

STUDIO

? ?

AREA A

EP

AREA B

FF

EP

(E) REF. 223 SF

2"

1001 EAST YALE AVE., DENVER, CO 80210

KEYPLAN

PAT. ROOM 8 215 SF

(E) MECH. 23 SF

AREA A

RENOVATION SCOPE

AREA B

NO WORK REQUIRED (FOR REFERENCE ONLY)

REFRIGERATOR

NOT IN SCOPE

SCHEMATIC DESIGN

8' - 0"

A3.10

1

19.

17

16.

15.

13.

12.

11.5

11.

SHEET TITLE

FIRST FLOOR PLAN AREA A

TTLBv.20150126

12/11/2017 1:27:37 PM

AREA A

FIRST FLOOR PLAN OF PORTER PLACE AREA A

1

FIRST FLOOR PLAN - AREA A

A2.10A

1/4" = 1'-0"

AREA B

PROJECT TRUE NORTH NORTH

PROJECT TRUE NORTH NORTH

SHEET NUMBER

A2.10A

THIS LINE IS 1 INCH LONG WHEN PRINTED TO FULL SCALE

C:\Revit Local Files\173235.00-A17 Central_rhouser.rvt

STUDIO


PROJECT NUMBER

173235.00 DRAWN BY

AW DATE

10/18/2017

REVISIONS

REV

PAT. ROOM 7 233 SF

STUDIO PAT. ROOM 7 233 SF

DATE

STUDIO PAT. ROOM 8 215 SF

? ?

AREA A

EP

AREA B

DESCRIPTION

AREA A

FF

EP

(E) REF. 223 SF

2"

(E) MECH. 23 SF

AREA B

REFRIGERATOR 8' - 0"

1

AMBULANCE VESTIBULE 81 SF

8' - 0"

A3.10

ACTIVITY

3' - 0"

GG

DINING

PRACTICE STAIRS

2

PARALLEL BARS

MULTIPURPOSE ROOM/CONSULT 86 SF

PRINTER

STAFF WORK 275 SF

RECUMBENT EXERCISER - NUSTEP T5

HH

STANDING FRAME DJO - WEIGHT RACK WEIGHT RACK - DJO GLOBAL

PYXIS REFRIG.

STAFF LOUNGE 122 SF

CLEAN WORK/ HOLD 44 SF

PYXIS

STUDIO

STAFF TOILET 44 SF EP

A3.10

PATIO

CROSS TRAINER/ BIKE FLOOR COPIER

DESIRED EQUIPMENT: Electric Hi/Low Mat table Parallel bars Practice stairs Standing frame Small treatment table or high low table Chair with arms US/E stim Exercise balls Small set of weights Theraband If space allows a stationary bike

STUDIO

THERAPY STORAGE 44 SF

1' - 6"

THERAPY BAY 76 SF

FORCE PLATE - NATUS NEUROCOM VSR

BALL/BAND STOR.

PT TABLE - METRON PLUS HI-LO 6'-8'

WIRE SHELVING

II

EP EP

TOILET 48 SF

PAT. ROOM 10 233 SF

STUDIO

STUDIO

PAT. ROOM 9 226 SF

Boulder Associates, Inc. Architecture + Interior Design 1426 Pearl Street, Suite 300 Boulder , Colorado 80302 303.499.7795 www.boulderassociates.com

TOILET 45 SF

JJ

EP

4' - 0"

PAT. ROOM 11 (ISO) 196 SF

STUDIO

STUDIO PAT. ROOM 12 213 SF

TOILET 42 SF

EP

EP

C:\Revit Local Files\173235.00-A17 Central_rhouser.rvt

STAIR

PROJECT

KK

PORTER PLACE SNF REHAB RENOVATION ADDRESS

KEYPLAN

UP

1001 EAST YALE AVE., DENVER, CO 80210

LL 19.

17

16.

15.

13.

12.

11.5

RENOVATION SCOPE

NO WORK REQUIRED (FOR REFERENCE ONLY)

11.

NOT IN SCOPE

TTLBv.20150126

12/11/2017 1:27:40 PM

AREA A

1

FIRST FLOOR PLAN - AREA B

A2.10B

1/4" = 1'-0"

SCHEMATIC DESIGN

SHEET TITLE

FIRST FLOOR PLAN AREA B PROJECT TRUE NORTH NORTH

AREA B

PROJECT TRUE NORTH NORTH

SHEET NUMBER

A2.10B

THIS LINE IS 1 INCH LONG WHEN PRINTED TO FULL SCALE

TOILET 52 SF

FIRST FLOOR PLAN OF PORTER PLACE AREA B


PROJECT NUMBER

173193.06 DRAWN BY

R. HOUSER DATE

1

2

3

4

5

6

7

09/13/2017

REVISIONS

REV

DESCRIPTION

DATE

G

F.1

F

STAFF

KITCHEN

STAFF

53 SF

LOUNGE

TARGET: 60 SF L 6' - 6" x W 8' - 1"

WAITING

295 SF

TARGET: 240 SF L 24' - 7" x W 12' - 0"

BILLING 391 SF

?

WAITING

TARGET: 270 SF L 21' - 3" x W 18' - 5"

560 SF

TARGET: 560 SF L 24' - 4" x W 23' - 0"

STAFF

STAFF

TOILET

CONFERENCE

60 SF

367 SF

TARGET: 50 SF L 7' - 0" x W 8' - 7"

TARGET: 300 SF L 24' - 7" x W 14' - 11"

WAITING WAITING

BOOK KEEPING 165 SF

E

TARGET: 120 SF L 10' - 0" x W 16' - 6"

COPY 151 SF

CLINIC

STORAGE

TARGET: 100 SF L 10' - 11" x W 13' - 10"

TARGET: 100 SF L 14' - 5" x W 10' - 5"

VEST

HAZ PREP

TARGET: 60 SF L 10' - 5" x W 7' - 0"

TARGET: 80 SF L 13' - 8" x W 7' - 0"

96 SF

73 SF

312 SF

TARGET: 335 SF L 17' - 11" x W 17' - 5"

CLINIC

CLINIC

150 SF

WAITING

RECEPTION

CLINIC

LAB

100 SF WAITING

TARGET: 100 SF L 14' - 5" x W 6' - 11"

ADMIN

CLINIC

PHARM, COMP, SUPPLY

120 SF

D.1

TARGET: 120 SF L 10' - 0" x W 12' - 0"

WAITING

CLINIC

VITALS

WORK / COPIER

TARGET: 90 SF L 10' - 11" x W 8' - 3"

TARGET: 140 SF L 17' - 11" x W 8' - 8"

363 SF

STAFF

CLINIC

60 SF

60 SF

TARGET: 50 SF L 7' - 1" x W 8' - 5"

TARGET: 45 SF L 7' - 0" x W 8' - 6"

TARGET: 260 SF L 24' - 7" x W 14' - 9"

TOILET BLOOD DRAW

155 SF

90 SF

CLINIC

EXAM

D

3 5/8"

CLINIC

INFUSION

100 SF

209 SF

TARGET: 100 SF L 10' - 0" x W 10' - 0"

TARGET: 150 SF L 24' - 7" x W 8' - 6"

CLINIC

CLINIC

CLINIC

CLINIC

CLINIC

EXAM

EXAM

EXAM

EXAM

100 SF

TARGET: 100 SF L 10' - 0" x W 10' - 0"

TARGET: 100 SF L 10' - 0" x W 10' - 0"

TARGET: 100 SF L 10' - 0" x W 10' - 0"

TARGET: 100 SF L 10' - 0" x W 10' - 0"

100 SF

EXAM

100 SF

100 SF

100 SF

Boulder Associates, Inc. Architecture + Interior Design 1426 Pearl Street, Suite 300 Boulder , Colorado 80302 303.499.7795 www.boulderassociates.com

TARGET: 100 SF L 10' - 0" x W 10' - 0"

WAITING

RESEARCH CLINIC

CLINIC

100 SF

1241 SF

CLINIC

EXAM

EXAM

EXAM

TARGET: 100 SF L 10' - 0" x W 10' - 0"

TARGET: 100 SF L 10' - 0" x W 10' - 0"

TARGET: 100 SF L 10' - 0" x W 10' - 0"

TARGET: 100 SF L 10' - 0" x W 10' - 0"

100 SF

EXAM

CLINIC

CLINIC

EXAM

TARGET: 100 SF L 10' - 0" x W 10' - 0"

100 SF

100 SF

CLINIC

TARGET: 1245 SF L 24' - 2" x W 53' - 4"

100 SF

CLINIC

STANDING

STANDING

TARGET: 41 SF L 20' - 4" x W 2' - 0"

TARGET: 41 SF L 20' - 5" x W 2' - 0"

41 SF

41 SF

PROJECT

CLINIC

PROCEDURE 120 SF

TARGET: 240 SF L 10' - 1" x W 11' - 11"

C:\Revit Local Files\173193.00 - Swedish MOB-A18 Central_rhouser.rvt

C

CLINIC

CLINIC

CLINIC

CLINIC

CLINIC

WORK

WORK

WORK

WORK

WORK

TARGET: 30 SF L 5' - 6" x W 5' - 6"

TARGET: 30 SF L 5' - 6" x W 5' - 6"

TARGET: 30 SF L 5' - 6" x W 5' - 6"

TARGET: 30 SF L 5' - 6" x W 5' - 6"

TARGET: 30 SF L 5' - 6" x W 5' - 6"

30 SF

30 SF

30 SF

30 SF

30 SF

CLINIC

CLINIC

WORK

WORK

TARGET: 30 SF L 5' - 6" x W 5' - 6"

TARGET: 30 SF L 5' - 6" x W 5' - 6"

30 SF

30 SF

CLINIC

CLINIC

CLINIC

WORK

WORK

WORK

TARGET: 30 SF L 5' - 6" x W 5' - 6"

TARGET: 30 SF L 5' - 6" x W 5' - 6"

TARGET: 30 SF L 5' - 9" x W 5' - 6"

30 SF

30 SF

32 SF

CLINIC

CLINIC

CLINIC

CLINIC

187 SF

90 SF

90 SF

90 SF

TARGET: 30 SF L 21' - 4" x W 8' - 9"

TARGET: 120 SF L 10' - 4" x W 8' - 9"

TARGET: 120 SF L 10' - 4" x W 8' - 9"

TARGET: 120 SF L 10' - 4" x W 8' - 9"

PROCEDURE

MD

MD

MD

SWEDISH MOB MOVEMENT DISORDERS CENTER ADDRESS

B

1

FLOOR 3

1/8" = 1'-0"

TTLBv.20150126 9/13/2017 3:37:40 PM

A5.21

SPACE PLANNING DIAGRAM FOR SWEDISH MOB

SCHEMATIC DESIGN

SHEET TITLE

SPACE PLANNING

SHEET NUMBER

A5.21

THIS LINE IS 1 INCH LONG WHEN PRINTED TO FULL SCALE

D.5


TOP: CASEWORK COURSING. BOTTOM: CONFERENCE ROOM DESIGN OPTIONS


REVIT WORK  