Page 211

TECHNICAL ASPECTS

INSTALLATION INSTALLATION GEOMETRY ON CONCRETE - THREADED RODS (TYPE INA or MGS)

s c hmin c

s

d

[mm]

M8

M10

M12

M16

M20

M24

M27

M30

d0

[mm]

10

12

14

18

22

26

30

35

hef,min

[mm]

60

60

70

80

90

96

108

120

hef,max

[mm]

160

200

240

320

400

480

540

600

df

[mm]

9

12

14

18

22

26

30

33

Tinst

[Nm]

10

20

40

80

120

160

180

200

M8

M10

M12

M16

M20

M24

M27

M30

Minimum spacing

smin

[mm]

max (hef / 2; 5d)

Minimum edge distance

cmin

[mm]

max (hef / 2; 5d)

Minimum thickness of concrete support

hmin

[mm]

hef + 30 ≥ 100 mm

hef + 2 d0

For spacing and distances smaller than the critical ones, strength values have to be reduced depending on the installation parameters.

Tinst tfix

df L hef

h1

hmin

d = anchor diameter d0 = hole diameter in the concrete support hef = effective anchor depth df = maximum hole diameter in the element to be fastened

Tinst = tightening torque L = anchor length tfix = maximum fastening thickness h1 = minimum hole depth

d d0

INSTALLATION TIME AND TEMPERATURE support temperature + 5 ÷ + 9 °C

curing time before loading

workability time dry support

wet support 100 h

+ 10 ÷ + 14 °C

120 min 45 min

50 h 30 h

+ 15 ÷ + 19 °C

25 min

18 h

36 h

+ 20 ÷ + 29 °C

12 min

10 h

20 h

+ 30 ÷ + 39 °C

6 min

6h

12 h

+ 40 °C

5 min

4h

8h

60 h

Cartridge storage temperature + 5 ÷ + 25 °C

COMPLEMENTARY PRODUCTS | EPO-FIX PLUS | 211

FALL PROTECTION AND SAFETY - EN  

RELIABILITY CERTIFIED As the manufacturer, Rothoblaas is responsible for certifying its products. All the products documentation (certifica...

FALL PROTECTION AND SAFETY - EN  