PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

ELECTRICAL NOTES

ELECTRICAL POWER LEGEND

ALL ELECTRICAL POINTS TO BE ALIGNED AND EQUALLY SPACED. ALL ELECTRICAL POINTS TO BE CENTRED, UNLESS OTHERWISE INDICATED.

ALL ELECTRICAL WORK TO CONFORM WITH THE SABS 0400 AND MUNICIPAL BY-LAWS. A ELECTRICAL CERTIFICATE OF COMPLIANCE HAS TO BE ISSUED ON THE COMPLETION OF THE ELECTRICAL INSTALLATION.

SINGLE 15 AMP PLUG POINT

S.P. 300

SPEED POINT

300

DOUBLE 15 AMP PLUG POINT

TEL 300

TELEPHONE POINT

D.P. 300

DEDICATED CLEAN POWER POINT

FAX 300

FAX POINT

W 300

SINGLE 15 AMP WATERPROOF PLUG POINT

DATA 300

DATA POINT, INDEPENDANTLY LINKED CONDUITING

W 300

DOUBLE 15 AMP WATERPROOF PLUG POINT

BELL

S 300

3 PHASE STOVE POWER POINT

BUZZER

D

E 1650

STOVE EXTRACTOR FAN POWER POINT

PUSH BUTTON

W

I 1050

ISOLATER SWITCH

FIRE ALARM

W

P 300

POWER POINT

BURGLAR ALARM / SIREN

3 PH. 300

3 PHASE POWER POINT

SECURITY KEYPAD

S 1050

SHAVER / DRYER POWER POINT

PANIC BUTTON

G.D. 1050

GARAGE DOOR OPENER

INFRARED DETECTOR

REMOTE CONTROLLED GARAGE / GATE MOTOR

INFRARED REMOTE RECEIVER

RECESSED DIRECTIONAL LOW VOLTAGE CABINET LIGHT FITTING, TILTED TO ANGLE AS SHOWN

G.D.

P

U.P.S.

UNINTERUPTED POWER SUPPLY

C.P.

SECURITY CONTROL PANEL

ELECTRICAL LIGHTING LEGEND

LIGHT SWITCH

PENDANT FITTING

LIGHT SWITCH WITH DIMMER

HIGH BAY PENDANT

2

2 WAY LIGHT SWITCH

CEILING / SURFACE MOUNTED FITTING

2

2 WAY LIGHT SWITCH WITH DIMMER

RECESSED LOW VOLTAGE LIGHT FITTING

3

3 WAY LIGHT SWITCH

RECESSED DIRECTIONAL LOW VOLTAGE LIGHT FITTING, TILTED TO ANGLE AS SHOWN

3

3 WAY LIGHT SWITCH WITH DIMMER

RECESSED LOW VOLTAGE FLOOR LIGHT FITTING

WATERPROOF LIGHT SWITCH

STALK OR SUSPENDED LOW VOLTAGE LIGHT FITTING

2 WAY WATERPROOF LIGHT SWITCH

STALK OR SUSPENDED LOW VOLTAGE LIGHT FITTING ON TRACK / CABLE

TIMED SWITCH

STALK OR SUSPENDED DIRECTIONAL LOW VOLTAGE LIGHT FITTING, TILTED TO ANGLE AS SHOWN

D

D

T

2

STALK OR SUSPENDED DIRECTIONAL LOW VOLTAGE LIGHT FITTING ON TRACK / CABLE, TILTED TO ANGLE AS SHOWN

2000

SECURITY CONDUIT OUTLET POINT

LOW VOLTAGE TRACK, LENGTH SHOWN

RECESSED LOW VOLTAGE CABINET LIGHT FITTING

POOL PUMP

I

INTERCOM

RECESSED METAL HALIDE LIGHT FITTING

DISTRUBUTION BOARD

I

INTERCOM WITH CAMERA

RECESSED DIRECTIONAL METAL HALIDE LIGHT FITTING, TILTED TO ANGLE AS SHOWN

SUB. BOARD

SPEAKERS

SURFACE MOUNTED METAL HALIDE LIGHT FITTING

M

METER BOARD

VOLUME CONTROL

G

HOT WATER CYLINDER

TELEVISION POINT

THERMOSTAT: U/F HEATING / AIR CONDITIONING

FIRE HOSE REEL

S.B.

RECESSED WALL MOUNTED LIGHT FITTING 300

WALL MOUNTED LIGHT FITTING

WALL MOUNTED UP/DOWN LIGHT FITTING

300

RECESSED WATERPROOF WALL MOUNTED LIGHT FITTING

300

1800

RECESSED LIGHT FITTING

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

ANY DISCREPANCIES OR AMBIGUITY IN DRAWINGS OR SPECIFICATION HAS TO BE CLARIFIED IN WRITING BY THE CONTRACTOR (OR SELECTED ELECTRICAL SUB-CONTRACTOR), WITH THE ARCHITECT. INCORRECT INTERPRETATION WHICH RESULTS IN ALTERATIONS SHALL BE MADE GOOD BY THE CONTRACTOR (OR SELECTED ELECTRICAL SUB-CONTRACTOR), AT HIS OWN EXPENSE.

ELECTRICAL SWITCH LEGEND

300

ALL HEIGHT SHOWN ARE FROM STRUCTURAL SLAB LEVEL TO THE CENTRE OF THE INDIVIDUAL FITTING, UNLESS OTHERWISE INDICATED. ALL SWITCHES TO BE AT ......mm ABOVE SSL (TO THE CENTRE OF THE FITTING), UNLESS OTHERWISE INDICATED.

ELECTRICAL ANCILLARY LEGEND

300

EXTRACTOR FAN

WATERPROOF WALL MOUNTED LIGHT FITTING 300 S

POWER SKIRTING

WATERPROOF WALL MOUNTED LIGHT FITTING WITH SENSOR 1800

25mm PVC CONDUIT TO ROOF?

WATERPROOF GARDEN SPIKE LIGHT FITTING

FLOOD LIGHT 1800

WATERPROOF FLOOD LIGHT 1800 S WATERPROOF FLOOD LIGHT WITH SENSOR 1800

T

TRANSFORMER

1200

SINGLE TUBE FLOURESCENT, LENGTH GIVEN

DOUBLE TUBE FLOURESCENT, LENGTH GIVEN 1200

RECESSED TRIPPLE TUBE FLOURESCENT, LENGTH GIVEN 1200

ROPE LIGHT

CEILING FAN

SPRINKLER HEADS

* ALL DIMENSIONS TO BE CHECKED ON SITE BEFORE ANY WORK IS PUT IN HAND. * ALLE MATES MOET OP TERREIN NAGEGAAN WORD ALVORENS WERK IN AANVANG NEEM. * COPYRIGHT RESERVED / KOPIEREG VOORBEHOU * ALL WORK TO COMPLY TO LOCAL MUNICIPAL BY-LAWS. * ALLE WERK MOET VOLDOEN AAN PLAASLIKE STADSRAADS-REGULASIES.

CAPE TOWN First Floor, Uitzicht, 163 Tygerberg Ofiice Park, Plattekloof, 8500 Tel: (021) 930 9210/ Fax: (021) 930 9211 PO Box 51168 / Waterfront / 8002 mail@boogertmanct.co.za

PRETORIA

REV. No.

DATE DRAWN

DESCRIPTION

Tel: (012) 346 8686/ Fax: (012) 346 8687

DURBAN Tel: (031) 265 1805/ Fax: (031) 265 1811

JOHANNESBURG Tel: (011) 790 1600/ Fax: (011) 463 1197

BOOGERTMAN

+ PARTNERS ARCHITECTS

DRAWING

PROPOSED NEW RENAULT MOTOR DEALERSHIP ERF 15852 SOMERSET WEST LANDGRO DEVELOPMENT (Pty) Ltd

GROUND FLOOR PLAN

SCALE

1 : 100

DATE

PROJECT No.

DRAWING No.

0488

100

REVISION

30.05.2005 DRAWN

B+P/CT/AMG

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

REVISION RECORD

PROJECT

A

SCHEDULE-ELECTRICAL  

W 300 W 300 S 300 WATERPROOF FLOOD LIGHT WITH SENSOR REMOTE CONTROLLED GARAGE / GATE MOTOR WATERPROOF WALL MOUNTED LIGHT FITTING WITH SENSOR...