Page 1

All requirements of municipal and other authorities concerned have to be adhered to. Contractors and sub-contractors are to check all dimensions and levels on the site before commencing with work. Figured dimensions to be taken in prefenrence to scaled measurements and large scale detail supercede small scale drawings. The design on this drawing is the property of Fourie Architects and is copyright.

All windows blocked up and secured

3450 U/S of ceiling

2230 U/S of R/C beam

2530

existing shopfront

Concrete canopy

LADY GREY STR

Window blocked up and secured New partition 60mm step

NEW STR

DIAGRAMMATICAL SECTION A - A SCALE 1 : 100

6.92m boundary line

All windows blocked up and secured

NEW STR

39.44m boundary line

18.67m boundary line

45.65m boundary line

2250

1650

4480

FFL - U/S of ceiling = 3390mm

STRONG ROOM

560 x 560mm egg grate grill

New self closing 1/2 fire resistant doors with panic bolt & signage

230

510

1 x 4.5kg DCP & signage to SANS 10400

Position of fresh air supply fans designed by Mechanical ventilation specialist.

U/S of beam 2470 AFFL

ARCHITECT: . . . . . . . . . . . . . . . . . . SACAP # 2946

OWNER

: ..................

60mm step 560 x 560mm egg grate grill

1 x 4.5kg DCP & signage to SANS 10400

FFL - U/S of ceiling = 3450mm

New 90mm drywall partitioning to ceiling height by specialists

New 90mm drywall partitioning to ceiling height by specialists

FHR & 1 x 4.5kg DCP & signage to SANS 10400

PROPOSED TENNANT INSTALLATION TO FOOTGEAR SHOP, ERF NO 24291, PAARL.

10920

1 x 4.5kg DCP & signage to SANS 10400

OFFICE

STORE

IT SERVER SDB

EXISTING TOILETS

STAFF ROOM

1350 110 900 110 900 110 Line of existing roof

39.31m boundary line

All windows blocked up and secured

SCALE 1 : 100 Mechanical ventilation @ 7.5 l/s with outlet grills to doors designed by Mechanical ventilation specialist.

whb EXISTING TEA KITCHEN sink

FFL - U/S of ceiling = 3450mm

METER ROOM

Vp

Vp

2360

whb

2480

Vp

1550

New double swing double door

E-pos / Email: info@fourarch.co.za

Both windows blocked up and secured

FL

D 2470 AF

8270

Whirlybird extractor fan designed by Mechanical ventilation specialist. New 90mm drywall partitioning to ceiling height by specialists

Parkstraat 10 Park street Posbus / P.O. Box 2130 Durbanville Bellville 7550 7535 Tel (021) 976 0400 Fax 086 512 6962

13430

560 x 560mm egg grate grill

8520

19.37m boundary line

560 x 560mm egg grate grill

BULKHEA

Line of canopy above

existing shopfront

LADY GREY STR

3560

3010

1650

1 : 30 ramp up

SITE PLAN

19.4m boundary line

160

bulkhead

TOILET

whb

wc

TENNANT INSTALLATION.

New Rhinoboard ceiling 2,1m above F.F.L. only over 2 toilets Extractor fan to each WC cubicle designed by Mechanical ventilation specialist.

426C

2001

-

39150

1 : 100